Observium_CE/mibs/huawei/HUAWEI-R2-MIB

947 lines
30 KiB
Plaintext

-- ============================================================================
-- Copyright (C) 2011 by HUAWEI TECHNOLOGIES. All rights reserved.
-- Description: This MIB module defines MIB objects which provides R2 attribute management.
-- Reference:
-- Version: V1.02
-- ============================================================================
HUAWEI-R2-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, private
FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
TEXTUAL-CONVENTION
FROM SNMPv2-TC
IpAddress,TimeTicks,Counter32,Integer32
FROM SNMPv2-SMI
RowStatus,DisplayString
FROM SNMPv2-TC
huaweiUtility
FROM HUAWEI-MIB;
hwR2Protocol MODULE-IDENTITY
LAST-UPDATED "201111230000Z"
ORGANIZATION "Huawei Technologies Co., Ltd."
CONTACT-INFO
"Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://www.huawei.com
Email: support@huawei.com
"
DESCRIPTION
"
This MIB module defines MIB objects which provides R2 attribute management.
"
-- Revision history
REVISION "201207310000Z"
DESCRIPTION "V1.02, modify the description of hwRegisterOutgoingSignalType and hwRegisterIncomingSignalType"
REVISION "201111230000Z"
DESCRIPTION "V1.00, R2 attribute configure create a new mib document "
::= { huaweiUtility 108 }
hwR2Objects OBJECT IDENTIFIER ::= { hwR2Protocol 1 }
hwR2ProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwR2ProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
R2 signaling profile table,this table is used to add,modify,del,query R2 profile templet.
The index of this table is hwR2ProfileIndex
"
::= { hwR2Objects 1 }
hwR2ProfileEntry OBJECT-TYPE
SYNTAX HwR2ProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
R2 signaling profile table,this table is used to add,modify,del,query R2 profile templet.
The index of this entry is hwR2ProfileIndex
"
INDEX {
hwR2ProfileIndex
}
::= { hwR2ProfileTable 1 }
HwR2ProfileEntry ::=
SEQUENCE
{
hwR2ProfileIndex Integer32,
hwSignalName OCTET STRING,
hwSignalType Integer32,
hwR2SignalProfileRowStatus RowStatus
}
hwR2ProfileIndex OBJECT-TYPE
SYNTAX Integer32(0..15)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
R2 signaling profile index
"
::= { hwR2ProfileEntry 1 }
hwSignalName OBJECT-TYPE
SYNTAX OCTET STRING(SIZE (1..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
R2 signaling profile name
"
::= { hwR2ProfileEntry 2 }
hwSignalType OBJECT-TYPE
SYNTAX Integer32(0..15)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
R2 signaling type
"
::= { hwR2ProfileEntry 3 }
hwR2SignalProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Row status of R2 signaling profile
"
::= { hwR2ProfileEntry 4 }
hwRegisterSignalAttributeTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwRegisterSignalAttributeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
R2 register signaling attribute table,this table is used to set and query r2 profile register attribute
The index of this table is hwRegisterSignalIndex
"
::= { hwR2Objects 2 }
hwRegisterSignalAttributeEntry OBJECT-TYPE
SYNTAX HwRegisterSignalAttributeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
R2 register signaling attribute table,this table is used to set and query r2 profile register attribute
The index of this entry is hwRegisterSignalIndex
"
INDEX {
hwRegisterSignalIndex
}
::= { hwRegisterSignalAttributeTable 1 }
HwRegisterSignalAttributeEntry ::=
SEQUENCE
{
hwRegisterSignalIndex Integer32,
hwRegisterOutgoingSignalType INTEGER,
hwSignalSendVoltage Integer32,
hwBackPulseTime Integer32,
hwDTMFSendTime Integer32,
hwDTMFSendInterval Integer32,
hwNoCallerPermit INTEGER,
hwNumberMaxInterval Integer32,
hwSignalKeepMaxTime Integer32,
hwReceiveNumberMaxInterval Integer32,
hwSignalStopPermitTime Integer32,
hwWaitCallerCategoryTime Integer32,
hwWaitBsignalTime Integer32,
hwNumberSendMode INTEGER,
hwCallingNumberMaxLength Integer32,
hwCompellingSequenceKeepaliveTime Integer32,
hwSendPulseSignal INTEGER,
hwRegisterIncomingSignalType INTEGER
}
hwRegisterSignalIndex OBJECT-TYPE
SYNTAX Integer32(0..15)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
R2 signaling profile index
"
::= { hwRegisterSignalAttributeEntry 1 }
hwRegisterOutgoingSignalType OBJECT-TYPE
SYNTAX INTEGER{mfc(1),pulse(2),dtmf(3),mfp(4),dpmfp(5)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Signaling type of outgoing office register
Options:
1. mfc(1)-the register outgoing signal type is mfc
2. pulse(2) -the register outgoing signal type is pulse
3. dtmf(3) -the register outgoing signal type is dtmf
4. mfp(4) -the register outgoing signal type is mfp
5. dpmfp(5) -the register outgoing signal type is dpmfp
"
DEFVAL { mfc }
::= { hwRegisterSignalAttributeEntry 2 }
hwSignalSendVoltage OBJECT-TYPE
SYNTAX Integer32(1..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Register signal transmit level(dbm)
1:-25dBm
2:-24dBm
3:-23dBm
4:-22dBm
5:-21dBm
6:-20dBm
7:-19dBm
8:-18dBm
9:-17dBm
10:-16dBm
11:-15dBm
12:-14dBm
13:-13dBm
14:-12dBm
15:-11dBm
16:-10dBm
17:-9dBm
18:-8dBm
19:-7dBm
20:-6dBm
21:-5dBm
22:-4dBm
23:-3dBm}
"
DEFVAL { 14 }
::= { hwRegisterSignalAttributeEntry 3 }
hwBackPulseTime OBJECT-TYPE
SYNTAX Integer32(100..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Backword pulse duration(Multiple of 10; unit: ms)
"
DEFVAL { 150 }
::= { hwRegisterSignalAttributeEntry 4 }
hwDTMFSendTime OBJECT-TYPE
SYNTAX Integer32(50..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
DTMF signal transmit duration (ms)
"
DEFVAL { 68 }
::= { hwRegisterSignalAttributeEntry 5 }
hwDTMFSendInterval OBJECT-TYPE
SYNTAX Integer32(50..500)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
DTMF signal transmit interval (ms)
"
DEFVAL { 68 }
::= { hwRegisterSignalAttributeEntry 6 }
hwNoCallerPermit OBJECT-TYPE
SYNTAX INTEGER{yes(1),no(2)}
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"
Can the call be established without a calling party
Options:
1. yes(1)- permit send caller number
2. no(2) - not permit send caller number
"
::= { hwRegisterSignalAttributeEntry 7 }
hwNumberMaxInterval OBJECT-TYPE
SYNTAX Integer32(1..60)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Max. dialing interval (s)
"
DEFVAL { 50 }
::= { hwRegisterSignalAttributeEntry 8 }
hwSignalKeepMaxTime OBJECT-TYPE
SYNTAX Integer32(1..30)
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"
Max. signal duration (s)
"
::= { hwRegisterSignalAttributeEntry 9 }
hwReceiveNumberMaxInterval OBJECT-TYPE
SYNTAX Integer32(1..60)
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"
Max. interval of receiving calling(callee) signals (s)
"
::= { hwRegisterSignalAttributeEntry 10 }
hwSignalStopPermitTime OBJECT-TYPE
SYNTAX Integer32(1..30)
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"
Max. duration of signal interruption
"
::= { hwRegisterSignalAttributeEntry 11 }
hwWaitCallerCategoryTime OBJECT-TYPE
SYNTAX Integer32(1..60)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Wait time for receiving calling party type (s)
"
DEFVAL { 50 }
::= { hwRegisterSignalAttributeEntry 12 }
hwWaitBsignalTime OBJECT-TYPE
SYNTAX Integer32(1..60)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Wait time for receiving group B signal (s)
"
DEFVAL { 50 }
::= { hwRegisterSignalAttributeEntry 13 }
hwNumberSendMode OBJECT-TYPE
SYNTAX INTEGER{immediate(1),delay(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Signal transmit mode
Options:
1. immediate(1)- number send immediately
2. delay(2) - number send delay
"
DEFVAL { delay }
::= { hwRegisterSignalAttributeEntry 14 }
hwCallingNumberMaxLength OBJECT-TYPE
SYNTAX Integer32(0..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Max. length of calling number
"
DEFVAL { 12 }
::= { hwRegisterSignalAttributeEntry 15 }
hwCompellingSequenceKeepaliveTime OBJECT-TYPE
SYNTAX Integer32(0..60000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Compelling sequence keepalive time for register signaling (ms)
"
DEFVAL { 40000 }
::= { hwRegisterSignalAttributeEntry 16 }
hwSendPulseSignal OBJECT-TYPE
SYNTAX INTEGER{yes(1),no(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Whether to send sending-finished signals
Options:
1. yes(1)- send pulse signal
2. no(2) - do not send pulse signal
"
DEFVAL { no }
::= { hwRegisterSignalAttributeEntry 17 }
hwRegisterIncomingSignalType OBJECT-TYPE
SYNTAX INTEGER{mfc(1),pulse(2),dtmf(3),mfp(4),dpmfp(5)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Signaling type of incoming office register
Options:
1. mfc(1)-the register incoming signal type is mfc
2. pulse(2) -the register incoming signal type is pulse
3. dtmf(3) -the register incoming signal type is dtmf
4. mfp(4) -the register incoming signal type is mfp
5. dpmfp(5) -the register incoming signal type is dpmfp
"
DEFVAL { mfc }
::= { hwRegisterSignalAttributeEntry 18 }
hwLineSignalAttributeTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwLineSignalAttributeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
R2 line signaling attribute table,this table is used to set and query r2 profile line signal attribute.
The index of this table is hwLineSignalIndex
"
::= { hwR2Objects 3 }
hwLineSignalAttributeEntry OBJECT-TYPE
SYNTAX HwLineSignalAttributeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
R2 line signaling attribute table,this table is used to set and query r2 profile line signal attribute.
The index of this entry is hwLineSignalIndex
"
INDEX {
hwLineSignalIndex
}
::= { hwLineSignalAttributeTable 1 }
HwLineSignalAttributeEntry ::=
SEQUENCE
{
hwLineSignalIndex Integer32,
hwLineSignalType INTEGER,
hwWaitSeizeAckTime Integer32,
hwWaitAnswerTime Integer32,
hwWaitClearForwardTime Integer32,
hwWaitProtectTime Integer32
}
hwLineSignalIndex OBJECT-TYPE
SYNTAX Integer32(0..15)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
R2 profile index
"
::= { hwLineSignalAttributeEntry 1 }
hwLineSignalType OBJECT-TYPE
SYNTAX INTEGER{l1b(1),l2b(2),l3b(3),pulse(4)}
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"
Line signaling type
Options:
1. l1b(1)-line signal type is l1b
2. l2b(2) -line signal type is l2b
3. l3b(3) -line signal type is l3b
4. pulse(4) -line signal type is pulse
"
::= { hwLineSignalAttributeEntry 2 }
hwWaitSeizeAckTime OBJECT-TYPE
SYNTAX Integer32(0..7000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Wait time for receiving occupation verification signal (ms)
"
DEFVAL { 5000 }
::= { hwLineSignalAttributeEntry 3 }
hwWaitAnswerTime OBJECT-TYPE
SYNTAX Integer32(0..511)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Wait time for receiving answer signal (s)
"
DEFVAL { 300 }
::= { hwLineSignalAttributeEntry 4 }
hwWaitClearForwardTime OBJECT-TYPE
SYNTAX Integer32(0..2000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Wait time for receiving forward release signal (ms)
"
DEFVAL { 200 }
::= { hwLineSignalAttributeEntry 5 }
hwWaitProtectTime OBJECT-TYPE
SYNTAX Integer32(0..2000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Wait time for receiving release protection signal (ms)
"
DEFVAL { 200 }
::= { hwLineSignalAttributeEntry 6 }
hwAddressSendListTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwAddressSendListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Attribute table for sent R2 address,this table is used to set and query register address send attribute.
The index of this table is hwAddresssendInformationIndex
"
::= { hwR2Objects 4 }
hwAddressSendListEntry OBJECT-TYPE
SYNTAX HwAddressSendListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Attribute table for sent R2 address,this table is used to set and query register address send attribute.
The index of this entry is hwAddresssendInformationIndex
"
INDEX {
hwAddresssendInformationIndex
}
::= { hwAddressSendListTable 1 }
HwAddressSendListEntry ::=
SEQUENCE
{
hwAddresssendInformationIndex Integer32,
hwAddressSendInformationDI INTEGER,
hwAddressSendInformationSI INTEGER,
hwAddressSendInformationSC INTEGER,
hwAddressSendInformationES INTEGER,
hwAddressSendInformationCC INTEGER,
hwAddressSendInformationDISC INTEGER,
hwAddressSendInformationNAC INTEGER,
hwAddressSendInformationSP INTEGER
}
hwAddresssendInformationIndex OBJECT-TYPE
SYNTAX Integer32(0..15)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
R2 profile index
"
::= { hwAddressSendListEntry 1 }
hwAddressSendInformationDI OBJECT-TYPE
SYNTAX INTEGER{yes(1)}
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"
Whether to send called numbers
Options:
1. yes(1)-register signal address send callee number
"
::= { hwAddressSendListEntry 2 }
hwAddressSendInformationSI OBJECT-TYPE
SYNTAX INTEGER{yes(1),no(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Whether to send calling numbers
Options:
1. yes(1)-register signal address send caller number
2. no(2)-register signal address does not send caller number
"
DEFVAL { yes }
::= { hwAddressSendListEntry 3 }
hwAddressSendInformationSC OBJECT-TYPE
SYNTAX INTEGER{yes(1)}
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"
Whether to send calling party types
Options:
1. yes(1)-register signal address send caller type
"
::= { hwAddressSendListEntry 4 }
hwAddressSendInformationES OBJECT-TYPE
SYNTAX INTEGER{yes(1),no(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Whether to send echo cancelation info
Options:
1. yes(1)-register signal address send echo suppression
2. no(2)-register signal address does not send echo suppression
"
DEFVAL { no }
::= { hwAddressSendListEntry 5 }
hwAddressSendInformationCC OBJECT-TYPE
SYNTAX INTEGER{yes(1),no(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Whether to send country code
Options:
1. yes(1)-register signal address send country code
2. no(2)-register signal address does not send country code
"
DEFVAL { no }
::= { hwAddressSendListEntry 6 }
hwAddressSendInformationDISC OBJECT-TYPE
SYNTAX INTEGER{yes(1),no(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Whether to send separating signaling
Options:
1. yes(1)-register signal address send discrimination flag
2. no(2)-register signal address does not send discrimination flag
"
DEFVAL { no }
::= { hwAddressSendListEntry 7 }
hwAddressSendInformationNAC OBJECT-TYPE
SYNTAX INTEGER{yes(1),no(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Whether to send circuit basic info
Options:
1. yes(1)-register signal address send circuit character
2. no(2)-register signal address does not send circuit character
"
DEFVAL { no }
::= { hwAddressSendListEntry 8 }
hwAddressSendInformationSP OBJECT-TYPE
SYNTAX INTEGER{yes(1),no(2)}
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"
Whether to send the calling priority
Options:
1. yes(1)-register signal address send caller priority
2. no(2)-register signal address does not send caller priority
"
::= { hwAddressSendListEntry 9 }
hwAddressReceiveListTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwAddressReceiveListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Attribute table for received R2 address,this table is used to set and query register signal address receive attribute
The index of this table is hwAddressReceiveInformationIndex
"
::= { hwR2Objects 5 }
hwAddressReceiveListEntry OBJECT-TYPE
SYNTAX HwAddressReceiveListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Attribute table for received R2 address,this table is used to set and query register signal address receive attribute
The index of this entry is hwAddressReceiveInformationIndex
"
INDEX {
hwAddressReceiveInformationIndex
}
::= { hwAddressReceiveListTable 1 }
HwAddressReceiveListEntry ::=
SEQUENCE
{
hwAddressReceiveInformationIndex Integer32,
hwAddressReceiveInformationDI INTEGER,
hwAddressReceiveInformationSI INTEGER,
hwAddressReceiveInformationSC INTEGER,
hwAddressReceiveInformationES INTEGER,
hwAddressReceiveInformationCC INTEGER,
hwAddressReceiveInformationDISC INTEGER,
hwAddressReceiveInformationNAC INTEGER,
hwAddressReceiveInformationSP INTEGER,
hwRequestCallerLineNoPosition Integer32,
hwRequestCallerLineTypePosition Integer32
}
hwAddressReceiveInformationIndex OBJECT-TYPE
SYNTAX Integer32(0..15)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
R2 profile index
"
::= { hwAddressReceiveListEntry 1 }
hwAddressReceiveInformationDI OBJECT-TYPE
SYNTAX INTEGER{yes(1)}
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"
Whether to receive called numbers
Options:
1. yes(1)-register signal address receive callee number
"
::= { hwAddressReceiveListEntry 2 }
hwAddressReceiveInformationSI OBJECT-TYPE
SYNTAX INTEGER{yes(1),no(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Whether to receive calling numbers
Options:
1. yes(1)-register signal address receive calling number
2. no(2)-register signal address does not receive calling number
"
DEFVAL { yes }
::= { hwAddressReceiveListEntry 3 }
hwAddressReceiveInformationSC OBJECT-TYPE
SYNTAX INTEGER{yes(1),no(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Whether to receive calling party types
Options:
1. yes(1)-register signal address receive calling user type
2. no(2)-register signal address does not receive calling user type
"
DEFVAL { yes }
::= { hwAddressReceiveListEntry 4 }
hwAddressReceiveInformationES OBJECT-TYPE
SYNTAX INTEGER{yes(1),no(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Whether to receive echo cancelation info
Options:
1. yes(1)-register signal address receive echo suppression
2. no(2)-register signal address does not receive echo suppression
"
DEFVAL { no }
::= { hwAddressReceiveListEntry 5 }
hwAddressReceiveInformationCC OBJECT-TYPE
SYNTAX INTEGER{yes(1),no(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Whether to receive country code
Options:
1. yes(1)-register signal address receive country code
2. no(2)-register signal address does not receive country code
"
DEFVAL { no }
::= { hwAddressReceiveListEntry 6 }
hwAddressReceiveInformationDISC OBJECT-TYPE
SYNTAX INTEGER{yes(1),no(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Whether to receive separating signaling
Options:
1. yes(1)-register signal address receive distinctive indication
2. no(2)-register signal address does not receive distinctive indication
"
DEFVAL { no }
::= { hwAddressReceiveListEntry 7 }
hwAddressReceiveInformationNAC OBJECT-TYPE
SYNTAX INTEGER{yes(1),no(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Whether to receive circuit basic info
Options:
1. yes(1)-register signal address receive circuit character
2. no(2)-register signal address does not receive circuit character
"
DEFVAL { no }
::= { hwAddressReceiveListEntry 8 }
hwAddressReceiveInformationSP OBJECT-TYPE
SYNTAX INTEGER{yes(1),no(2)}
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"
Whether to receive calling priority
Options:
1. yes(1)-register signal address receive caller priority
2. no(2)-register signal address does not receive caller priority
"
::= { hwAddressReceiveListEntry 9 }
hwRequestCallerLineNoPosition OBJECT-TYPE
SYNTAX Integer32(1..12)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Called number digits before requesting calling number (The calling number must be requested after the calling party type.)
"
DEFVAL { 1 }
::= { hwAddressReceiveListEntry 10 }
hwRequestCallerLineTypePosition OBJECT-TYPE
SYNTAX Integer32(1..12)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Called number digits before requesting calling party type (The calling party type must be requested before the calling number.)
"
DEFVAL { 1 }
::= { hwAddressReceiveListEntry 11 }
hwR2SignalTypeVersionTable OBJECT IDENTIFIER ::={ hwR2Objects 6 }
hwSignalTypeVersion OBJECT-TYPE
SYNTAX OCTET STRING(SIZE (1..10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Version of R2 signaling type file
"
::= { hwR2SignalTypeVersionTable 1 }
hwR2SignalTypeTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwR2SignalTypeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
R2 signaling type table,this table is used to query R2 signal type information
The index of this table is hwSignalTypeIndex
"
::= { hwR2Objects 7 }
hwR2SignalTypeEntry OBJECT-TYPE
SYNTAX HwR2SignalTypeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
R2 signaling type table,this table is used to query R2 signal type information
The index of this entry is hwSignalTypeIndex
"
INDEX {
hwSignalTypeIndex
}
::= { hwR2SignalTypeTable 1 }
HwR2SignalTypeEntry ::=
SEQUENCE
{
hwSignalTypeIndex Integer32,
hwSignalTypeName OCTET STRING
}
hwSignalTypeIndex OBJECT-TYPE
SYNTAX Integer32(0..15)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
R2 signaling type index
"
::= { hwR2SignalTypeEntry 1 }
hwSignalTypeName OBJECT-TYPE
SYNTAX OCTET STRING(SIZE (0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
R2 signaling type name
The names of the preconfigured multiple countries adaption profiles with IDs ranging from 0 to 9 cannot be modified
"
::= { hwR2SignalTypeEntry 2 }
END