Observium_CE/mibs/hp/HPICF-TR069-MIB

248 lines
9.6 KiB
Plaintext

HPICF-TR069-MIB DEFINITIONS ::= BEGIN
-- ****************************************************************************
-- MIB for the HP ICF implementation of Broadband Forum Specification
-- TR-069 - CPE WAN Management Protocol (CWMP)
-- ****************************************************************************
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Unsigned32
FROM SNMPv2-SMI
DateAndTime
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
hpSwitch
FROM HP-ICF-OID;
hpicfTR069MIB MODULE-IDENTITY
LAST-UPDATED "201403030000Z" -- March 03, 2014
ORGANIZATION "HP Networking"
CONTACT-INFO "Hewlett-Packard Company
8000 Foothills Blvd.
Roseville, CA 95747"
DESCRIPTION "This MIB defines HP proprietary objects used to configure
the TR-069 feature."
REVISION "201403030000Z" -- March 03, 2014
DESCRIPTION "Initial version"
::= { hpSwitch 98 }
-- ****************************************************************************
-- This MIB module contains the following groups
-- ****************************************************************************
hpicfTR069Notifications OBJECT IDENTIFIER ::= { hpicfTR069MIB 0 }
hpicfTR069Objects OBJECT IDENTIFIER ::= { hpicfTR069MIB 1 }
hpicfTR069Conformance OBJECT IDENTIFIER ::= { hpicfTR069MIB 2 }
-- ****************************************************************************
-- Individual object definitions for TR-069
-- ****************************************************************************
hpicfTR069EnableCWMP OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable TR-069 on the device."
::= { hpicfTR069Objects 1 }
hpicfTR069CWMPDeviceType OBJECT-TYPE
SYNTAX INTEGER {
device (1),
gateway (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The working mode of the device. By default, the device
operates in gateway mode. CWMP should be disabled
before changing modes."
::= { hpicfTR069Objects 2 }
hpicfTR069AcsUrl OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..256))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The URL used by TR-069 to connect to the ACS.
The value should be a valid HTTP or HTTPS URL."
::= { hpicfTR069Objects 3 }
hpicfTR069AcsUrlOrigin OBJECT-TYPE
SYNTAX INTEGER {
none (1),
config (2),
dhcp (3),
acs (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The source of the ACS URL.
none - no ACS URL set
config - from the device configuration file
dhcp - from a DHCP server response
acs - from the ACS itself"
::= { hpicfTR069Objects 4 }
hpicfTR069AcsProxyUrl OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..256))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The URL used by TR-069 to connect to a proxy server
in order to reach the ACS. The value should be a
valid HTTP or HTTPS URL."
::= { hpicfTR069Objects 5 }
hpicfTR069AcsUsername OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..256))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The username for HTTP authentication with the ACS."
::= { hpicfTR069Objects 6 }
hpicfTR069AcsPassword OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..256))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The plaintext password for HTTP authentication with the ACS.
This object always returns an empty string when read."
::= { hpicfTR069Objects 7 }
hpicfTR069AcsPasswordEncrypted OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..384))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "An encrypted form of the ACS password. The value
should be an encrypted password previously read from
a compatible HP Networking device. This object can
only be read or written when
hpSwitchAuthenticationEncryptCredentialsMethod
is set to a value other than 'none' and cannot be set
at the same time as hpicfTR069AcsPassword."
::= { hpicfTR069Objects 8 }
hpicfTR069AcsConnectRetryInterval OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The ACS connection retry interval."
::= { hpicfTR069Objects 9 }
hpicfTR069CpeUsername OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..256))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The username for HTTP authentication with the
TR-069 client."
::= { hpicfTR069Objects 10 }
hpicfTR069CpePassword OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..256))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The plaintext password for HTTP authentication with
the TR-069 client. This object always returns an empty
string when read."
::= { hpicfTR069Objects 11 }
hpicfTR069CpePasswordEncrypted OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..384))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "An encrypted form of the client password. The value
should be an encrypted password previously read from
a compatible HP Networking device. This object can
only be read or written when
hpSwitchAuthenticationEncryptCredentialsMethod
is set to a value other than 'none' and cannot be set
at the same time as hpicfTR069CpePassword."
::= { hpicfTR069Objects 12 }
hpicfTR069CpeWaitTimeout OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The close-wait timeout of the ACS connection."
::= { hpicfTR069Objects 13 }
hpicfTR069PeriodicInformEnable OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The periodic inform message setting specified
by the ACS."
::= { hpicfTR069Objects 14 }
hpicfTR069PeriodicInformInterval OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The periodic inform interval in seconds specified
by the ACS."
::= { hpicfTR069Objects 15 }
hpicfTR069PeriodicInformTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time to send inform messages specified
by the ACS."
::= { hpicfTR069Objects 16 }
-- ****************************************************************************
-- MIB Conformance Information / Details
-- ****************************************************************************
hpicfTR069MIBCompliances OBJECT IDENTIFIER ::= { hpicfTR069Conformance 1 }
hpicfTR069MIBGroups OBJECT IDENTIFIER ::= { hpicfTR069Conformance 2 }
-- ****************************************************************************
-- Compliance Statements
-- ****************************************************************************
hpicfTR069MIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION "The compliance statement for HP switches implementing the
HPICF-TR069 MIB."
MODULE
MANDATORY-GROUPS { hpicfTR069Group }
::= { hpicfTR069MIBCompliances 1 }
-- ****************************************************************************
-- Conformance Groups
-- ****************************************************************************
hpicfTR069Group OBJECT-GROUP
OBJECTS {
hpicfTR069EnableCWMP,
hpicfTR069CWMPDeviceType,
hpicfTR069AcsUrl,
hpicfTR069AcsUrlOrigin,
hpicfTR069AcsProxyUrl,
hpicfTR069AcsUsername,
hpicfTR069AcsPassword,
hpicfTR069AcsPasswordEncrypted,
hpicfTR069AcsConnectRetryInterval,
hpicfTR069CpeUsername,
hpicfTR069CpePassword,
hpicfTR069CpePasswordEncrypted,
hpicfTR069CpeWaitTimeout,
hpicfTR069PeriodicInformEnable,
hpicfTR069PeriodicInformInterval,
hpicfTR069PeriodicInformTime
}
STATUS current
DESCRIPTION "A collection of objects to support the TR-069 feature."
::= { hpicfTR069MIBGroups 1 }
END