HP-OV-TOPO-DB DEFINITIONS ::= BEGIN
IMPORTS
IpAddress, Counter, Gauge
FROM RFC1155-SMI
enterprises FROM SNMPv2-SMI,
OBJECT-TYPE
FROM RFC-1212
DisplayString, PhysAddress
FROM RFC-1213;
hp OBJECT IDENTIFIER ::= { enterprises 11 }
nm OBJECT IDENTIFIER ::= { hp 2 }
openView OBJECT IDENTIFIER ::= { nm 17 }
hpOVDistribStation
OBJECT IDENTIFIER ::= { openView 4 }
--
-- type definitions
--
-- OpenView Object Identifier
OVID ::= INTEGER (SIZE (0..2147483647))
-- OpenView UUID
OVUUID ::= DisplayString (SIZE (36))
-- Seconds since 12:00am, January 1, 1970 used as a timestamp.
-- A value of 2^31 - 1 (21474383647) indicates MAXIMUM TIME.
OVTime ::= INTEGER (SIZE (0..2147483647))
-- The OV status of the object
OVStatus ::= INTEGER {
unknown(1),
normal(2),
minor(3),
critical(4),
unmanaged(5),
warning(6),
major(7),
restricted(8),
testing(9),
disabled(10)
}
-- The collection station type
OVStnType ::= INTEGER {
ovUx(1),
ovWindows(2), -- deprecated
ovWindowsNt(3)
}
-- OpenView segment types
OVSegType ::= INTEGER {
bus(1),
star(2),
tokenRing(3),
fddi(4),
serial(5)
}
IpxHostAddress ::= OCTET STRING (SIZE (10))
hpOVTopoDB OBJECT IDENTIFIER ::= { hpOVDistribStation 1 } -- hpOVDStnVersions=3,4,5,6
hpOVEventObjs OBJECT IDENTIFIER ::= { hpOVDistribStation 2 } -- hpOVDStnVersions=3,4,5,6
hpOVMgrs OBJECT IDENTIFIER ::= { hpOVDistribStation 3 } -- hpOVDStnVersions=3,4,5,6
-- netmon's workload profiler: maintained in HP-OV-NETMON
-- hpOVNetmon OBJECT IDENTIFIER ::= { hpOVDistribStation 4 }
-- topology database group
hpOVGlobal OBJECT IDENTIFIER ::= { hpOVTopoDB 1 } -- hpOVDStnVersions=3,4,5,6
hpOVNetworks OBJECT IDENTIFIER ::= { hpOVTopoDB 2 } -- hpOVDStnVersions=3,4,5,6
hpOVSegments OBJECT IDENTIFIER ::= { hpOVTopoDB 3 } -- hpOVDStnVersions=3,4,5,6
hpOVNodes OBJECT IDENTIFIER ::= { hpOVTopoDB 4 } -- hpOVDStnVersions=3,4,5,6
hpOVInterfaces OBJECT IDENTIFIER ::= { hpOVTopoDB 5 } -- hpOVDStnVersions=3,4,5,6
hpOVDStnType OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVStnType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Revision description identifier for the distribution
software. This object can be used to test whether an
agent is a collection station."
::= { hpOVGlobal 1 }
hpOVDStnVersion OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The version of the collection station implementation
type.
Version 3: NNM 4.1
Version 4: NNM 4.2"
::= { hpOVGlobal 2 }
hpOVDStnDescr OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A descriptive string for the collection station,
possibly containing type, version, and patch
information."
::= { hpOVGlobal 3 }
hpOVDStnManagedNodeCount OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of nodes currently managed locally by the
collection station."
::= { hpOVGlobal 4 }
hpOVDStnLicenseNodeLimit OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of managed nodes permitted by the
license. A value of -1 indicates no limit."
::= { hpOVGlobal 5 }
hpOVDStnLicenseExpDate OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time at which the license expires. A value of 0
indicates that there is no expiration date."
::= { hpOVGlobal 6 }
hpOVDStnTopoDBCreateTime OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time at which the topology database was created."
::= { hpOVGlobal 7 }
hpOVDStnEventSeqNr OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sequence number of the last event sent related to
topology changes."
::= { hpOVGlobal 8 }
hpOVDStnLocalTime OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a reference time for the collection station
and can be used to resolve any differences in time
between management and collection stations."
::= { hpOVGlobal 9 }
hpOVDStnFilterName OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The filter name to use when determining which objects
in the local topology to expose in the MIB."
::= { hpOVGlobal 10 }
hpOVDStnName OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The name used by the collection station when
referring to itself. This name will be sent as part
of the field change event (see hpOVEvtStnName)."
::= { hpOVGlobal 11 }
-- Only data related to the networks, segments, nodes, and interfaces
-- which are local to the collection station identity of the agent will
-- be reported.
-- the networks-by-ID table
netCount OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of networks in netByIDTable."
::= { hpOVNetworks 1 }
netByIDTable OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX SEQUENCE OF NetByIDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of networks by OpenView object identifier."
::= { hpOVNetworks 2 }
netByIDEntry OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX NetByIDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains relevant data for a network."
INDEX { netID }
::= { netByIDTable 1 }
NetByIDEntry ::= SEQUENCE {
netID OVID,
netTopoID OVUUID,
netName DisplayString,
netStatus OVStatus,
netAddr IpAddress,
netMask IpAddress,
netIfCount Gauge,
netSegCount Gauge,
netIpxAddr IpxHostAddress,
netIpxHopCount Gauge
}
netID OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"OpenView object identifier of the network."
::= { netByIDEntry 1 }
netTopoID OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVUUID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"OpenView UUID of the network."
::= { netByIDEntry 2 }
netName OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Name of the network, which will usually be the IP
address of the network or the corresponding entry in
/etc/networks.)"
::= { netByIDEntry 3 }
netStatus OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Status of the network as defined by the status
propogation rules of the topology database."
::= { netByIDEntry 4 }
netAddr OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Network's IP address."
::= { netByIDEntry 5 }
netMask OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Network's subnet mask."
::= { netByIDEntry 6 }
netIfCount OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of interfaces in the network."
::= { netByIDEntry 7 }
netSegCount OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of segments contained in the network."
::= { netByIDEntry 8 }
netIpxAddr OBJECT-TYPE -- hpOVDStnVersions=4,5,6
SYNTAX IpxHostAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Network's IPX address."
::= { netByIDEntry 9 }
netIpxHopCount OBJECT-TYPE -- hpOVDStnVersions=5,6
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of hops to this network from this station."
::= { netByIDEntry 10 }
-- the segments-by-ID table
segCount OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of segments in segByIDTable."
::= { hpOVSegments 1 }
segByIDTable OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX SEQUENCE OF SegByIDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of segments by OpenView object identifier."
::= { hpOVSegments 2 }
segByIDEntry OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX SegByIDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains relevant data for a segment."
INDEX { segID }
::= { segByIDTable 1 }
SegByIDEntry ::= SEQUENCE {
segID OVID,
segTopoID OVUUID,
segName DisplayString,
segStatus OVStatus,
segNetID OVID,
segIfCount Gauge,
segConnIfID OVID,
segType OVSegType
}
segID OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"OpenView object identifier of the segment."
::= { segByIDEntry 1 }
segTopoID OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVUUID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"OpenView UUID of the segment."
::= { segByIDEntry 2 }
segName OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Name of the segment."
::= { segByIDEntry 3 }
segStatus OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Status of the segment as defined by the status
propogation rules of the topology database."
::= { segByIDEntry 4 }
segNetID OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"OpenView object identifier for the network containing
the segment."
::= { segByIDEntry 5 }
segIfCount OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of interfaces in the segment."
::= { segByIDEntry 6 }
segConnIfID OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If this is a segment containing 'smart connectors',
this is the OpenView object identifier of the
interface on the 'main device' for the segment (e.g.,
the hub at the center of a star segment), otherwise
the value is 0."
::= { segByIDEntry 7 }
segType OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVSegType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The OpenView segment type."
::= { segByIDEntry 8 }
-- the nodes-by-ID table
nodeCount OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of nodes in nodeByIDTable."
::= { hpOVNodes 1 }
nodeByIDTable OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX SEQUENCE OF NodeByIDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of node by OpenView object identifier."
::= { hpOVNodes 2 }
nodeByIDEntry OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX NodeByIDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains relevant data for a node."
INDEX { nodeID }
::= { nodeByIDTable 1 }
NodeByIDEntry ::= SEQUENCE {
nodeID OVID,
nodeTopoID OVUUID,
nodeName DisplayString,
nodeStatus OVStatus,
nodeConnType INTEGER,
nodeSnmpAddr IpAddress,
nodeDescr DisplayString,
nodeLocation DisplayString,
nodeContact DisplayString,
nodeIfCount Gauge,
nodeSysObjectID OBJECT IDENTIFIER,
nodeIpForwarding INTEGER,
nodeSnmpSupportLevel INTEGER,
nodeIsClusterMember INTEGER,
nodeIsFileServer INTEGER,
nodeIsPrintServer INTEGER,
nodeSysName DisplayString,
nodeIsIpxRouter INTEGER,
nodeIsNetWareServer INTEGER,
nodeIpxServerName DisplayString,
nodeSnmpIpxAddr IpxHostAddress
}
nodeID OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"OpenView object identifier of the node."
::= { nodeByIDEntry 1 }
nodeTopoID OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVUUID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"OpenView UUID of the node."
::= { nodeByIDEntry 2 }
nodeName OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"IP hostname of the node including the fully qualified
doman (if used and available). It is derived by
performing a name lookup (gethostbyaddr) for the IP
address of the first interface of the node. If no
name exists for any of the interfaces of a node, the
name will be the IP address string."
::= { nodeByIDEntry 3 }
nodeStatus OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Status of the node as defined by the status
propogation rules of the topology database."
::= { nodeByIDEntry 4 }
nodeConnType OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX INTEGER {
-- nonConnector(0),
genericConnector(1),
router(2),
bridge(4),
hub(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Node connector type. This is a bit mask, thereby
allowing multiple values, i.e, a node can be a router
and a bridge. The genericConnector bit should always
be set if one of the more significant bits is set. If
the node is not a connector at all, this object will
be 0"
::= { nodeByIDEntry 5 }
nodeSnmpAddr OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"IP address used for SNMP request to the node."
::= { nodeByIDEntry 6 }
nodeDescr OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Value obtained from the node via SNMP from the
sysDescr object."
::= { nodeByIDEntry 7 }
nodeLocation OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Value obtained from the node via SNMP from the
sysLocation object."
::= { nodeByIDEntry 8 }
nodeContact OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Value obtained from the node via SNMP from the
sysContact object."
::= { nodeByIDEntry 9 }
nodeIfCount OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of interfaces of the node."
::= { nodeByIDEntry 10 }
nodeSysObjectID OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Value obtained from the node via SNMP from the
sysObjectID object. If there is no sysObjectID for
the node, 0.0 will be reported."
::= { nodeByIDEntry 11 }
nodeIpForwarding OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Value obtained from the node via SNMP from the
ipForwarding object."
::= { nodeByIDEntry 12 }
nodeSnmpSupportLevel OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX INTEGER {
none(1),
snmpV1(2),
snmpV2C(3),
snmpV1V2C(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The extent to which this node supports SNMP."
::= { nodeByIDEntry 13 }
nodeIsClusterMember OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX INTEGER {
false(1),
true(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates if this nodes is part of a cluster."
::= { nodeByIDEntry 14 }
nodeIsFileServer OBJECT-TYPE -- hpOVDStnVersions=4,5,6
SYNTAX INTEGER {
false(1),
true(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates if this nodes is a file server."
::= { nodeByIDEntry 15 }
nodeIsPrintServer OBJECT-TYPE -- hpOVDStnVersions=4,5,6
SYNTAX INTEGER {
false(1),
true(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates if this nodes is a print server."
::= { nodeByIDEntry 16 }
nodeSysName OBJECT-TYPE -- hpOVDStnVersions=5,6
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Value obtained from the node via SNMP from the
sysName object."
::= { nodeByIDEntry 17 }
nodeIsIpxRouter OBJECT-TYPE -- hpOVDStnVersions=5,6
SYNTAX INTEGER {
false(1),
true(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates if this nodes is an IPX router (but not a server)."
::= { nodeByIDEntry 18 }
nodeIsNetWareServer OBJECT-TYPE -- hpOVDStnVersions=5,6
SYNTAX INTEGER {
false(1),
true(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates if this nodes is an IPX/NetWare server."
::= { nodeByIDEntry 19 }
nodeIpxServerName OBJECT-TYPE -- hpOVDStnVersions=5,6
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Value obtained from the node via IPX for server nodes."
::= { nodeByIDEntry 20 }
nodeSnmpIpxAddr OBJECT-TYPE -- hpOVDStnVersions=5,6
SYNTAX IpxHostAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Node's IPX address."
::= { nodeByIDEntry 21 }
-- the interfaces-for-node table
nodeIfsTable OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX SEQUENCE OF NodeIfsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of interfaces for a node."
::= { hpOVNodes 3 }
nodeIfsEntry OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX NodeIfsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of entries for each node is given in
nodeIfCount. Each entry contains only the minimum
information needed to recognize and/or indentify the
interfaces for a node. For complete information, use
the ifID to lookup the entry in ifaceByIDTable."
INDEX { nodeNodeID, nodeIfID }
::= { nodeIfsTable 1 }
NodeIfsEntry ::= SEQUENCE {
nodeNodeID OVID,
nodeIfID OVID,
nodeIfAddr IpAddress
}
nodeNodeID OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"OpenView object identifier of the node."
::= { nodeIfsEntry 1 }
nodeIfID OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"OpenView object identifier of this interface of the node."
::= { nodeIfsEntry 2 }
nodeIfAddr OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"IP Address of this interface of the node (if any).
It is provided in the nodeIfsTable to aid in
identifying the interfaces associated with a node."
::= { nodeIfsEntry 3 }
-- the interface-by-ID table
ifCount OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of interfacess in ifByIDTable."
::= { hpOVInterfaces 1 }
ifByIDTable OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX SEQUENCE OF IfByIDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of interfaces by OpenView object identifier."
::= { hpOVInterfaces 2 }
ifByIDEntry OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX IfByIDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains relevant data for an interface."
INDEX { ifID }
::= { ifByIDTable 1 }
IfByIDEntry ::= SEQUENCE {
ifID OVID,
ifTopoID OVUUID,
ifName DisplayString,
ifStatus OVStatus,
ifAddr IpAddress,
ifMask IpAddress,
ifNumber INTEGER,
ifType INTEGER,
ifDescr DisplayString,
ifPhysAddr PhysAddress,
ifSegID OVID,
ifSegType OVSegType,
ifNetID OVID,
ifNodeID OVID,
ifSegConnIf INTEGER,
ifPortClass INTEGER,
ifCanMigrate INTEGER,
ifIpxAddr IpxHostAddress,
ifCritIfUuid OVUUID
}
ifID OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"OpenView object identifier of the interface."
::= { ifByIDEntry 1 }
ifTopoID OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVUUID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"OpenView UUID of the interface."
::= { ifByIDEntry 2 }
ifName OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The name of the interface, which is a shortened
version of the Value obtained via SNMP from the
ifDescr object for this interface."
::= { ifByIDEntry 3 }
ifStatus OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Status for the interface in the topology database:
either critical or normal."
::= { ifByIDEntry 4 }
ifAddr OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"IP address of the interface."
::= { ifByIDEntry 5 }
ifMask OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Subnet mask of the interface."
::= { ifByIDEntry 6 }
ifNumber OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Value obtained via SNMP from the ifIndex object for
this interface."
::= { ifByIDEntry 7 }
ifType OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Value obtained via SNMP from the ifType object in
ifTable for this interface."
::= { ifByIDEntry 8 }
ifDescr OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Value obtained via SNMP from the ifDescr object in
ifTable for this interface."
::= { ifByIDEntry 9 }
ifPhysAddr OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX PhysAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If the node to which this interface is connected
responds to SNMP, this is the value obtained via SNMP
from the ifPhysAddr object for this interface,
otherwise, this value was obtained from some other
node which knows about this interface. The
ifLinkAddressFrom object below indicates the IP
address from which ifPhysAddr was obtained."
::= { ifByIDEntry 10 }
ifSegID OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"OpenView object identifier for the segment containing
the interface."
::= { ifByIDEntry 11 }
ifSegType OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVSegType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The segment type in which this interface should be
contained."
::= { ifByIDEntry 12 }
ifNetID OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"OpenView object identifier for the network containing
the interface in the topology database."
::= { ifByIDEntry 13 }
ifNodeID OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"OpenView object identifier for the node containing
the interface in the topology database."
::= { ifByIDEntry 14 }
ifSegConnIf OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX INTEGER {
false(1),
true(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates if this interface is the one to connect the
'main device' (e.g., the hub at the center of a star
segment) to the segment."
::= { ifByIDEntry 15 }
ifPortClass OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"For devices for which OpenView can do 'smart' network
(i.e, bridges and hubs) submap layout, this indicates
which port this interface corresponds to on the
device, according to following:
Value Meaning
------- -------------------------------------
< 255 Corresponds to a single port (the
value '1' means 'port 1'). This type
of value is typical for bridges.
>= 255 Corresponds to a port group where the
port group number is obtained by
subracting 255 (the value '257' means
'port group 2'). This type of value
is typical for hubs.
Note: The port number OpenView uses will not
necessarily match the vendor port number, but will
start at 1 for the first non-port-group port. For
example, if a hub has 12 EtherTwist ports, identified
by the vendor as ports 1-12 and belonging to the same
port group, and also an AUI port identified by the
vendor as port 13, the AUI port will be port 1 for
purposes of OpenView.
For non-smart network connector devices, this value
should be 0 and can be ignored."
::= { ifByIDEntry 16 }
ifCanMigrate OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX INTEGER {
false(1),
true(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates if this interface can migrate from one node
in a cluster to another."
::= { ifByIDEntry 17 }
ifIpxAddr OBJECT-TYPE -- hpOVDStnVersions=4,5,6
SYNTAX IpxHostAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"IPX address of the interface."
::= { ifByIDEntry 18 }
ifCritIfUuid OBJECT-TYPE -- hpOVDStnVersions=6
SYNTAX OVUUID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"OpenView topology UUID of a related interface whose
(primary) failure has caused a (secondary) failure on
this interface. That is, this interface is now inaccessible
from the management stations netmon process. This field
is used for Event Correlation."
::= { ifByIDEntry 19 }
-- Event Objects Group
-- This group defines objects to be used in object field change
-- events, which are never instantiated.
hpOVEvtStnName OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX DisplayString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The name of the collection station issuing the
event."
::= { hpOVEventObjs 1 }
hpOVEvtSeqNr OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The sequence number of the event."
::= { hpOVEventObjs 2 }
hpOVEvtOpType OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX INTEGER {
add(1),
delete(2),
fieldChange(3)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The operation type of the OBJ_FLD_CHG_EV (OBJect
FieLD CHanGe EVent)."
::= { hpOVEventObjs 3 }
hpOVEvtOVID OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVID
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The OpenView object identifier of the object whose
field changed."
::= { hpOVEventObjs 4 }
hpOVEvtOVTopoID OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVUUID
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The OpenView UUID of the object whose field changed."
::= { hpOVEventObjs 5 }
hpOVEvtObjType OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX INTEGER {
hpOVNetwork(1),
hpOVSegment(2),
hpOVNode(3),
hpOVInterface(4)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The object type of the object whose
field changed."
::= { hpOVEventObjs 6 }
hpOVEvtTime OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX OVTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The time the field change occured."
::= { hpOVEventObjs 7 }
-- Connected Management Group
mgmtStnTable OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX SEQUENCE OF MgmtStnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of active management stations by IP address."
::= { hpOVMgrs 1 }
mgmtStnEntry OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX MgmtStnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains all data available for a
management station."
INDEX { mgmtStnAddr }
::= { mgmtStnTable 1 }
MgmtStnEntry ::= SEQUENCE {
mgmtStnAddr IpAddress,
mgmtStnName DisplayString,
mgmtStnAccess INTEGER,
mgmtStnStatus INTEGER
}
mgmtStnAddr OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Primary IP Address of the management station."
::= { mgmtStnEntry 1 }
mgmtStnName OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP Hostname of the management station."
DEFVAL { "" }
::= { mgmtStnEntry 2 }
mgmtStnAccess OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX INTEGER {
readOnly(1),
readWrite(2) -- not yet supported
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Access level of the management station. The
management will attempt to set this object to the
desired level, but the collection station software
will reset to the access permission allowed by the
SNMPv2 party configuration."
DEFVAL { 1 }
::= { mgmtStnEntry 3 }
mgmtStnStatus OBJECT-TYPE -- hpOVDStnVersions=3,4,5,6
SYNTAX INTEGER {
active(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Status of the management station as viewed by the
collection station. The management station must set
this object to active(1) when it is creates an entry for
itself. The management station sets this object to
delete(2) when it wants to delete itself from the
table. The value delete(2) should never actually be
reported."
DEFVAL { 1 }
::= { mgmtStnEntry 4 }