Observium_CE/mibs/hp/HP-ICF-OPENFLOW-MIB

1654 lines
77 KiB
Plaintext

-- ***********************************************************************
-- Module: hpicfOpenFlow.mib
--
-- Copyright (C) 2012,2014-2017 Hewlett Packard Enterprise Development LP
-- All Rights Reserved.
--
-- The contents of this software are proprietary and confidential to
-- the Hewlett Packard Enterprise Development LP. No part of this
-- program may be photocopied, reproduced, or translated into another
-- programming language without prior written consent of the
-- Hewlett Packard Enterprise Development LP.
--
-- Purpose: This file contains MIB definition of HP-ICF-OPENFLOW-MIB
--
-- ***********************************************************************
HP-ICF-OPENFLOW-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter64, Unsigned32
FROM SNMPv2-SMI
TruthValue, RowStatus, DisplayString
FROM SNMPv2-TC
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
InterfaceIndex, ifIndex
FROM IF-MIB
InetAddressType, InetAddress, InetPortNumber
FROM INET-ADDRESS-MIB
hpSwitch
FROM HP-ICF-OID
PortList
FROM Q-BRIDGE-MIB
VidList
FROM HP-ICF-TC;
hpicfOpenFlowMIB MODULE-IDENTITY
LAST-UPDATED "201803270000Z" -- March 27, 2018
ORGANIZATION "HP Networking"
CONTACT-INFO
"Hewlett Packard Company
8000 Foothills Blvd.
Roseville, CA 95747"
DESCRIPTION
"Added all option
hpicfOpenFlowInstanceOverrideProtocol mib object."
REVISION "201803270000Z" -- March 27, 2018
DESCRIPTION
"The MIB module for configuring OpenFlow."
REVISION "201707160000Z" -- July 16, 2017
DESCRIPTION
"Added a mib object hpicfOpenFlowControllerSourceAddressType
corresponding to the source IP when configuring a controller.
Updated compliance."
REVISION "201706180000Z" -- June 18, 2017
DESCRIPTION
"Added a mib object hpicfOpenFlowControllerSourceAddress
for source IP when configuring a controller."
REVISION "201704280000Z" -- April 28, 2017
DESCRIPTION
"Added traditionalPipeline option
hpicfOpenFlowInstanceOverrideProtocol mib object."
REVISION "201610250000Z" -- October 25, 2016
DESCRIPTION
"Removed bfd protocol in
hpicfOpenFlowInstanceOverrideProtocol mib object."
REVISION "201610050000Z" -- October 05, 2016
DESCRIPTION
"Added mib object
hpicfOpenFlowInstanceMeterPrecedenceLevel."
REVISION "201608060000Z" -- August 6, 2016
DESCRIPTION
"Removed two protocols, dtiscp and webmacauth in
hpicfOpenFlowInstanceOverrideProtocol mib object.
Also modified the BITS numbering of other protocols."
REVISION "201607310000Z" -- July 31, 2016
DESCRIPTION
"Added mib object
hpicfOpenFlowInstanceMissRuleDefaultAction
hpicfOpenFlowInstanceOverrideProtocol
hpicfOpenFlowInstancePktInVlanTagging"
REVISION "201604210000Z" -- April 21, 2016
DESCRIPTION
"Removed mib object
hpicfOpenFlowInstanceGroupHWCounterAvailability."
REVISION "201512100000Z" -- December 10, 2015
DESCRIPTION
"Added new enum in following MIB object hpicfOpenFlowInstanceOperStatusReason,
disabled enum is added in this MIB object"
REVISION "201509290000Z" -- September 29, 2015
DESCRIPTION
"The following MIB object changes in hpicfOpenFlowInstanceOperStatusReason,
hardwareFailure is renamed to enableFailedInHardware.
controllerVLANRemoved is removed"
REVISION "201501110000Z" -- January 11, 2015
DESCRIPTION
"Added support for OpenFlow MAC group tables in the pipeline"
REVISION "201406040000Z" -- June 4, 2014
DESCRIPTION
"Added mib objects
hpicfOpenFlowInstanceMembers
hpicfOpenFlowInstancePipelineModel
hpicfOpenFlowInstanceDatapathDesc
Deprecated the table
hpicfOpenFlowInstanceMembershipTable and mib object
hpicfOpenFlowIpControlTableMode.
Deprecated groups are
hpicfOpenFlowInstanceGroup
hpicfOpenFlowInstanceMembershipGroup
hpicfOpenFlowScalarsGroup. Added new groups
hpicfOpenFlowInstanceGroup1
hpicfOpenFlowScalarsGroup1.
Deprecated the compliance
hpicfOpenFlowCompliance and added hpicfOpenFlowCompliance1."
REVISION "201210010000Z" -- October 16, 2012
DESCRIPTION
"Added support for OpenFlow Specification 1.3"
REVISION "201202010000Z" -- February 01, 2012
DESCRIPTION
"The initial version of this MIB module"
::= { hpSwitch 89}
-- -------------------------------------------------------------
-- Start of MIB Objects
-- -------------------------------------------------------------
hpicfOpenFlowNotifications OBJECT IDENTIFIER ::= { hpicfOpenFlowMIB 0 }
hpicfOpenFlowObjects OBJECT IDENTIFIER ::= { hpicfOpenFlowMIB 1 }
hpicfOpenFlowConformance OBJECT IDENTIFIER ::= { hpicfOpenFlowMIB 2 }
--
-- MIB objects
--
hpicfOpenFlowStatus OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2),
disableWithClearConfig (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Global configuration to enable or disable
OpenFlow on the device.
The 'disableWithClearConfig' enum disables
OpenFlow along with removing all the
OpenFlow related configuration."
DEFVAL { disable }
::= { hpicfOpenFlowObjects 1}
----------------------------------------------------------
-- OpenFlow instance table
----------------------------------------------------------
hpicfOpenFlowInstanceTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpicfOpenFlowInstanceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table that is used create an OpenFlow instance.
For maximum number of OpenFlow instances
that can be supported, refer to
hpicfOpenFLowMaxInstances MIB object."
::= { hpicfOpenFlowObjects 4 }
hpicfOpenFlowInstanceEntry OBJECT-TYPE
SYNTAX HpicfOpenFlowInstanceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A set of objects that are used to create an
OpenFlow instance."
INDEX { hpicfOpenFlowInstanceName}
::= { hpicfOpenFlowInstanceTable 1 }
HpicfOpenFlowInstanceEntry ::=
SEQUENCE {
hpicfOpenFlowInstanceName SnmpAdminString,
hpicfOpenFlowInstanceAdminStatus INTEGER,
hpicfOpenFlowInstanceListenPortCfg TruthValue,
hpicfOpenFlowInstanceListenPort InetPortNumber,
hpicfOpenFlowInstanceListenPortIsOobm TruthValue,
hpicfOpenFlowInstanceMode INTEGER,
hpicfOpenFlowInstanceFlowLocationMode INTEGER,
hpicfOpenFlowConnectionInterruptionMode INTEGER,
hpicfOpenFlowInstanceHwRateLimit Integer32,
hpicfOpenFlowInstanceSwRateLimit Integer32,
hpicfOpenFlowInstanceDatapathID Counter64,
hpicfOpenFlowInstanceNumOfHwFlows Counter64,
hpicfOpenFlowInstanceNumOfSwFlows Counter64,
hpicfOpenFlowInstanceOperStatus INTEGER,
hpicfOpenFlowInstanceMaxBackOffInterval Unsigned32,
hpicfOpenFlowInstanceRowStatus RowStatus,
hpicfOpenFlowInstanceProbeInterval Unsigned32,
hpicfOpenFlowInstanceProtoVersion INTEGER,
hpicfOpenFlowInstanceProtoVersionOnly TruthValue,
hpicfOpenFlowInstanceNumOfSwFlowTable Unsigned32,
hpicfOpenFlowInstanceOperStatusReason INTEGER,
hpicfOpenFlowInstanceEgressOnlyPorts PortList,
hpicfOpenFlowInstanceCapabilities BITS,
hpicfOpenFlowInstanceHwTableMissCount Counter64,
hpicfOpenFlowInstanceTableModel INTEGER,
hpicfOpenFlowInstanceMembers VidList,
hpicfOpenFlowInstancePipelineModel INTEGER,
hpicfOpenFlowInstanceDatapathDesc DisplayString,
hpicfOpenFlowInstanceSourceMacGrpTable INTEGER,
hpicfOpenFlowInstanceDestMacGrpTable INTEGER,
hpicfOpenFlowInstanceMissRuleDefaultAction INTEGER,
hpicfOpenFlowInstanceOverrideProtocol BITS,
hpicfOpenFlowInstancePktInVlanTagging INTEGER
}
hpicfOpenFlowInstanceName OBJECT-TYPE
SYNTAX SnmpAdminString(SIZE(1..32))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Unique name given to an OpenFlow instance.
The instance name 'aggregate' is special case
denoting switch functioning as OpenFlow switch.
The instance name allows lowercase alphanumeric
characters and the special character underscore."
::= { hpicfOpenFlowInstanceEntry 1}
hpicfOpenFlowInstanceAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object is used to administratively enable
or disable an OpenFlow instance. This MIB
object can be set to 'enable' only when either
hpicfOpenFlowInstanceListenPortCfg has been
set to 'true' or atleast one controller is
associated with this instance."
DEFVAL { disable }
::= { hpicfOpenFlowInstanceEntry 2}
hpicfOpenFlowInstanceListenPortCfg OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object indicates if a listen-port is
configured on this OpenFlow instance."
DEFVAL { false }
::= { hpicfOpenFlowInstanceEntry 3}
hpicfOpenFlowInstanceListenPort OBJECT-TYPE
SYNTAX InetPortNumber
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Port number for the listen-port on the
OpenFlow instance. A valid port number is
between 1024 and 65534 inclusive."
DEFVAL { 6633 }
::= { hpicfOpenFlowInstanceEntry 4}
hpicfOpenFlowInstanceListenPortIsOobm OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object indicates if a listen-port is
configured for this OpenFlow instance over
OOBM(Out Of Band Management) interface.
This MIB object will be applicable only if
there is a physical OOBM port on the device."
DEFVAL { false }
::= { hpicfOpenFlowInstanceEntry 5}
hpicfOpenFlowInstanceMode OBJECT-TYPE
SYNTAX INTEGER {
active(1),
passive(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows the user to specify the
mode of OpenFlow operation for an instance.
In active mode, new flows get redirected to
the OpenFlow controller. In passive mode,
new flows are not sent to the OpenFlow
controller.This object is applicable
only for an OpenFlow version 1.0 instance."
DEFVAL { active }
::= { hpicfOpenFlowInstanceEntry 6}
hpicfOpenFlowInstanceFlowLocationMode OBJECT-TYPE
SYNTAX INTEGER {
hardwareOnly (1),
hardwareAndSoftware (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object specifies if the flows for this
instance will be located in hardware only or
in hardware and software. By default, flows
will be located in hardware and software.This
object is applicable only for an OpenFlow
version 1.0 instance."
DEFVAL { hardwareAndSoftware }
::={ hpicfOpenFlowInstanceEntry 7}
hpicfOpenFlowConnectionInterruptionMode OBJECT-TYPE
SYNTAX INTEGER {
failSecure (1),
failStandalone (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This MIB object is used to specify the type
of fallback when the switch loses connection
with the controller. In fail-secure mode,
packets and messages destined to the current
controller are dropped. Flows should continue
to expire according to their timeouts in
fail-secure mode. In fail-standalone mode, the
switch acts as a legacy Ethernet switch or
router."
REFERENCE "OpenFlow Spec-v1.1.0, Section 5.3"
DEFVAL { failSecure }
::= { hpicfOpenFlowInstanceEntry 8}
hpicfOpenFlowInstanceHwRateLimit OBJECT-TYPE
SYNTAX Integer32
UNITS "kilobits per second"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object limits the bandwidth per module
in kilobits per second, that this OpenFlow
instance can utilize. This implementation
supports a minimum rate limit of 0 kbps and
a maximum rate limit of 10000000 kbps."
::= { hpicfOpenFlowInstanceEntry 9}
hpicfOpenFlowInstanceSwRateLimit OBJECT-TYPE
SYNTAX Integer32
UNITS "packets per second"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object limits the number of packets per
second for each module, that this instance
can send to the software path on the CPU.
Increasing the software rate limit would
increase CPU consumption and may impact the
system performance. For maximum number of
packets per second for each module, that an
OpenFlow instance can send to the software
path on the CPU, refer to
hpicfOpenFLowInstanceMaxSwRateLimit MIB object."
DEFVAL { 100 }
::= { hpicfOpenFlowInstanceEntry 10}
hpicfOpenFlowInstanceDatapathID OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Datapath ID(DPID) uniquely identifies a
datapath between this instance and the
controller. Its lower 48-bits are intended for
switch MAC address, while the upper 16-bits
are defined by the implementation."
REFERENCE "OpenFlow Spec-v1.1.0, Appendix A.3.1"
::= { hpicfOpenFlowInstanceEntry 11}
hpicfOpenFlowInstanceNumOfHwFlows OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object indicates the number of hardware
flows in this OpenFlow instance."
::= { hpicfOpenFlowInstanceEntry 12}
hpicfOpenFlowInstanceNumOfSwFlows OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object indicates the number of software
flows in this OpenFlow instance."
::= { hpicfOpenFlowInstanceEntry 13}
hpicfOpenFlowInstanceOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up (1),
down (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object is used to determine the
operational state of an OpenFlow instance.
The reason for operational status to be
down is specified by the
hpicfOpenFlowInstanceOperStatusReason MIB."
::= { hpicfOpenFlowInstanceEntry 14}
hpicfOpenFlowInstanceMaxBackOffInterval OBJECT-TYPE
SYNTAX Unsigned32(1..3600)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Interval between two consecutive attempts
made by an instance to reconnect to a
controller increases exponentially till it
reaches the value specified by this MIB
object. All subsequent attempts use this
value as the interval between retries."
DEFVAL { 60 }
::= { hpicfOpenFlowInstanceEntry 15}
hpicfOpenFlowInstanceRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Row status for this table."
::= { hpicfOpenFlowInstanceEntry 16}
hpicfOpenFlowInstanceProbeInterval OBJECT-TYPE
SYNTAX Unsigned32(1..3600)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This MIB object specifies the interval
between two consecutive probes sent from
an instance to the controller. This MIB
value also determines how soon the instance
will enter the connection interruption mode.
If the instance does not hear a reply from
the controller for three consecutive probes,
it will flag the controller as unreachable
and enter connection interruption mode."
DEFVAL { 10 }
::= { hpicfOpenFlowInstanceEntry 17}
hpicfOpenFlowInstanceProtoVersion OBJECT-TYPE
SYNTAX INTEGER {
v1dot0 (1),
v1dot3 (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This MIB object specifies the
OpenFlow instance protocol version."
DEFVAL { v1dot3 }
::= { hpicfOpenFlowInstanceEntry 18}
hpicfOpenFlowInstanceProtoVersionOnly OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Setting this MIB object to true will support
only the specific version mentioned by
hpicfOpenFlowInstanceProtoVersion MIB and not
compatible with lower versions."
DEFVAL { false }
::= { hpicfOpenFlowInstanceEntry 19}
hpicfOpenFlowInstanceNumOfSwFlowTable OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This MIB object specifies the number of
software flow tables for this OpenFlow
instance. The maximum value supported is 8.
This object is applicable only for
an OpenFlow version 1.3 instance."
DEFVAL { 1 }
::= { hpicfOpenFlowInstanceEntry 20}
hpicfOpenFlowInstanceOperStatusReason OBJECT-TYPE
SYNTAX INTEGER{
notApplicable(1),
hardwareResourcesUnavailable(2),
memberVLANNotConfigured(3),
memberVLANRemoved(4),
noValidPortsInMemberVLAN(5),
controllerVLANNotConfigured(6),
enableFailedInHardware(7),
disabled(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This MIB object specifies the reason for
hpicfOpenFlowInstanceOperStatus to be down."
::= { hpicfOpenFlowInstanceEntry 21}
hpicfOpenFlowInstanceEgressOnlyPorts OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This MIB object specifies the list of egress
only ports for this OpenFlow instance."
::= { hpicfOpenFlowInstanceEntry 22}
hpicfOpenFlowInstanceCapabilities OBJECT-TYPE
SYNTAX BITS {
flowStatistics (0),
tableStatistics (1),
portStatistics (2),
groupStatistics (3),
meterStatistics (4),
blockPorts (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This MIB object specifies the instance
capabilities exchanged with the controller."
::= { hpicfOpenFlowInstanceEntry 23}
hpicfOpenFlowInstanceHwTableMissCount OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This MIB object specifies the number of
packets which do not match any rules in the
hardware table. This object is applicable
only for an OpenFlow version 1.0 instance."
::= { hpicfOpenFlowInstanceEntry 24}
hpicfOpenFlowInstanceTableModel OBJECT-TYPE
SYNTAX INTEGER {
none(1),
singleTable (2),
policyEngineAndSoftware (3),
ipControlWithPolicyEngineAndSoftware (4),
customPipeline (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This MIB object determines the table model
of an OpenFlow instance."
::= { hpicfOpenFlowInstanceEntry 25}
hpicfOpenFlowInstanceMembers OBJECT-TYPE
SYNTAX VidList
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This MIB object is used to add member VLANs to an
OpenFlow instance."
::= { hpicfOpenFlowInstanceEntry 26 }
hpicfOpenFlowInstancePipelineModel OBJECT-TYPE
SYNTAX INTEGER {
none(0),
standardMatch(1),
ipcontrolTable(2),
customPipeline(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This MIB object is used to configure the openflow
instance pipeline model.
A value of 0(none) indicates no table pipeline model
which is equal to standard match.
A value of 1(standardMatch) enables an instance in
advertising its policy-engine and software tables.
A value of 2(ipControlTable) enables an OpenFlow 1.3
instance in advertising its IP control table.
A value of 3(customPipeline) enables an OpenFlow
controller to create a custom OpenFlow table pipeline in
the OpenFlow 1.3 instance."
DEFVAL { none }
::= { hpicfOpenFlowInstanceEntry 27}
hpicfOpenFlowInstanceDatapathDesc OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB object is a user-defined description of the data
path. If not set, hpicfOpenFlowInstanceName is used."
::= { hpicfOpenFlowInstanceEntry 28 }
hpicfOpenFlowInstanceSourceMacGrpTable OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object is used to enable or disable the source
MAC group table in the OpenFlow pipeline. This MIB
object can be set to 'enable' only on one instance."
DEFVAL { disable }
::= { hpicfOpenFlowInstanceEntry 29}
hpicfOpenFlowInstanceDestMacGrpTable OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object is used to enable or disable the destination
MAC group table in the OpenFlow table. This MIB
object can be set to 'enable' only on one instance."
DEFVAL { disable }
::= { hpicfOpenFlowInstanceEntry 30}
hpicfOpenFlowInstanceMissRuleDefaultAction OBJECT-TYPE
SYNTAX INTEGER {
none(0),
drop(1),
normal(2),
ctrl(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This MIB object is used to configure the flow miss
action associated with the instance.
A value of 0(none) indicates no flow miss action
specified, which is to drop all unknown packets.
A value of 1(drop) enables an instance to drop all
unknown packets.
A value of 2(normal) enables an instance to forward
all unknown packets using non-OpenFlow pipeline.
A value of 3(ctrl) enables an instance to forward
all unknown packets to the OpenFlow controller."
DEFVAL { none }
::= { hpicfOpenFlowInstanceEntry 31}
hpicfOpenFlowInstanceOverrideProtocol OBJECT-TYPE
SYNTAX BITS {
stp(0),
gvrp(1),
mvrp(2),
lacp(3),
dot1x(4),
udld(5),
loopprotect(6),
pvst(7),
smartlink(8),
dldp(9),
bonjour(10),
traditionalPipeline(11),
all(31)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This MIB object is used to configure the Override
protocol associated with the instance."
::= { hpicfOpenFlowInstanceEntry 32}
hpicfOpenFlowInstancePktInVlanTagging OBJECT-TYPE
SYNTAX INTEGER {
default(0),
inputForm(1),
tagAlways(2),
untagAlways(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This MIB object is used to configure the 802.1q
tagging property for a packet encapsulated inside
the OpenFlow packet-in header.
A value of 0 (default) indicates the default behavior
which is the packet encapsulated inside a packet-in
message will be tagged in the following cases
a) the instance type is aggregate.
b) the instance is a named instance with more than one
member VLAN.
c) the instance is a named instance and the packet was
received with a tag.
It will be untagged in all other cases.
A value of 1 (inputForm) directs the instance to send
the encapsulated packet as it was received on the
physical port.
A value of 2 (tagAlways) directs the instance to send
the encapsulated packet always with an 802.1q tag
irrespective of how it was received on the physical
port.
A value of 3 (untagAlways) directs the instance to
send the encapsulated packet always without an 802.1q
tag irrespective of how it was received on the
physical port."
DEFVAL { default }
::= { hpicfOpenFlowInstanceEntry 33}
----------------------------------------------------------
-- OpenFlow member table for OpenFlow instances
----------------------------------------------------------
hpicfOpenFlowInstanceMembershipTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpicfOpenFlowInstanceMembershipEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "Table used to add members to OpenFlow instances.
This table is deprecated and instead object
hpicfOpenFlowInstanceMembers is used to configure members
for an OpenFlow instance."
::= { hpicfOpenFlowObjects 5 }
hpicfOpenFlowInstanceMembershipEntry OBJECT-TYPE
SYNTAX HpicfOpenFlowInstanceMembershipEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "A set of objects that are used to add members
to an OpenFlow instance."
INDEX {
hpicfOpenFlowInstanceName,
ifIndex
}
::= { hpicfOpenFlowInstanceMembershipTable 1 }
HpicfOpenFlowInstanceMembershipEntry ::=
SEQUENCE {
hpicfOpenFlowInstanceMembershipRowStatus RowStatus
}
hpicfOpenFlowInstanceMembershipRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION "Row status for this member."
::= {hpicfOpenFlowInstanceMembershipEntry 2}
----------------------------------------------------------
-- OpenFlow controller table for OpenFlow instances
----------------------------------------------------------
hpicfOpenFlowControllerTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpicfOpenFlowControllerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table used to configure controllers. For
maximum number of OpenFlow controllers
that can be supported, refer to
hpicfOpenFlowMaxControllers MIB object."
::= { hpicfOpenFlowObjects 6 }
hpicfOpenFlowControllerEntry OBJECT-TYPE
SYNTAX HpicfOpenFlowControllerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A set of objects that are used to configure
OpenFlow Controllers."
INDEX { hpicfOpenFlowControllerID}
::= { hpicfOpenFlowControllerTable 1 }
HpicfOpenFlowControllerEntry ::=
SEQUENCE {
hpicfOpenFlowControllerID Integer32,
hpicfOpenFlowControllerInetAddressType InetAddressType,
hpicfOpenFlowControllerInetAddress InetAddress,
hpicfOpenFlowControllerPort InetPortNumber,
hpicfOpenFlowControllerInterface InterfaceIndex,
hpicfOpenFlowControllerRowStatus RowStatus,
hpicfOpenFlowControllerSourceAddressType InetAddressType,
hpicfOpenFlowControllerSourceAddress InetAddress
}
hpicfOpenFlowControllerID OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Unique ID given to a Controller. This will be
associated with an instance through
hpicfOpenFlowInstanceControllerTable."
::= { hpicfOpenFlowControllerEntry 1}
hpicfOpenFlowControllerInetAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Address type of this controller. This
implementation supports only ipv4 type."
::= {hpicfOpenFlowControllerEntry 2}
hpicfOpenFlowControllerInetAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION "IP Address of the controller."
::= {hpicfOpenFlowControllerEntry 3}
hpicfOpenFlowControllerPort OBJECT-TYPE
SYNTAX InetPortNumber
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The port over which the controller can be
reached."
::= {hpicfOpenFlowControllerEntry 4}
hpicfOpenFlowControllerInterface OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This MIB object specifies an interface over
which the controller is reachable."
::= { hpicfOpenFlowControllerEntry 5}
hpicfOpenFlowControllerRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Row status for this table. The
hpicfOpenFlowControllerInetAddress and
hpicfOpenFlowControllerInterface MIB objects
have to be set to valid values to move this
object to 'active' state. This conceptual row
can be deleted only if the corresponding
controller association is removed from the
hpicfOpenFlowInstanceControllerTable."
::= {hpicfOpenFlowControllerEntry 6}
hpicfOpenFlowControllerSourceAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Address type of the Source IP. This
implementation supports only ipv4 type."
::= {hpicfOpenFlowControllerEntry 7}
hpicfOpenFlowControllerSourceAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Source IP address to use when connecting
to the controller."
::= {hpicfOpenFlowControllerEntry 8}
----------------------------------------------------------
-- OpenFlow Instance-Controller Connection State table
----------------------------------------------------------
hpicfOpenFlowInstanceControllerTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpicfOpenFlowInstanceControllerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table that contains objects for connection
state and status between an OpenFlow instance
and a controller."
::= { hpicfOpenFlowObjects 8 }
hpicfOpenFlowInstanceControllerEntry OBJECT-TYPE
SYNTAX HpicfOpenFlowInstanceControllerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A set of objects used to monitor the status
and state of connection between an OpenFlow
instance and controller."
INDEX {
hpicfOpenFlowInstanceName,
hpicfOpenFlowControllerID
}
::= { hpicfOpenFlowInstanceControllerTable 1 }
HpicfOpenFlowInstanceControllerEntry ::=
SEQUENCE {
hpicfOpenFlowInstanceControllerStatus INTEGER,
hpicfOpenFlowInstanceControllerState INTEGER,
hpicfOpenFlowInstanceControllerRole INTEGER,
hpicfOpenFlowInstanceControllerConnSecure TruthValue,
hpicfOpenFlowInstanceControllerRowStatus RowStatus
}
hpicfOpenFlowInstanceControllerStatus OBJECT-TYPE
SYNTAX INTEGER {
connected (1),
disconnected (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Connection status between an OpenFlow
instance and a controller."
::= {hpicfOpenFlowInstanceControllerEntry 1}
hpicfOpenFlowInstanceControllerState OBJECT-TYPE
SYNTAX INTEGER {
void(1),
backoff(2),
connecting(3),
active(4),
idle(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Connection state between an OpenFlow
instance and a controller. The state 'void'
implies that there is no connection. The state
'backoff' represents a state where the device
is attempting to reconnect to the controller
at increasing intervals of time. The state
'connecting' represents a state where the
device is in the process of connecting to the
controller. The state 'active' implies that a
connection has been established and that the
controller is responsive. The state 'idle'
implies that the connection is idle and
waiting for a response."
::= {hpicfOpenFlowInstanceControllerEntry 2}
hpicfOpenFlowInstanceControllerRole OBJECT-TYPE
SYNTAX INTEGER {
equal (1),
conductor (2),
member (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Role of a controller in an instance. The
default role of a controller is equal. In this
role, the controller has full access to the
switch and is equal to other controllers in
the same role. In member role, the controller
has read-only access to the switch. The
conductor role is similar to equal and has full
access to the switch, the difference is that
the switch ensures it is the only controller
in this role. When a controller changes its
role to conductor, the switch changes all other
controllers with the role conductor to have the
role member."
::= {hpicfOpenFlowInstanceControllerEntry 3}
hpicfOpenFlowInstanceControllerConnSecure OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object indicates if the connection
between the controller and instance is secure.
Setting this MIB to true will initiate TLS as
transport protocol."
DEFVAL { false }
::= { hpicfOpenFlowInstanceControllerEntry 4}
hpicfOpenFlowInstanceControllerRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Row status for this table. Row transition to
'createAndWait', 'notReady' and
'notInService' states are not allowed."
::= { hpicfOpenFlowInstanceControllerEntry 5}
-- ------------------------------------------------------------
-- OpenFlow - Scalar Objects
-- ------------------------------------------------------------
hpicfOpenFlowMaxInstances OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This MIB object specifies the maximum number
of OpenFlow instances."
::= { hpicfOpenFlowObjects 10}
hpicfOpenFlowMaxFlows OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This MIB objects specifies the total number
of flows that can be supported on the switch.
That is, the sum of all hardware flows and
software flows across all OpenFlow instances
cannot exceed this number."
::= { hpicfOpenFlowObjects 11}
hpicfOpenFlowMaxControllers OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This MIB object specifies the maximum number
of OpenFlow controllers."
::= { hpicfOpenFlowObjects 12}
----------------------------------------------------------
-- OpenFlow Instance Meter table
----------------------------------------------------------
hpicfOpenFlowInstanceMeterTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpicfOpenFlowInstanceMeterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table that contains objects related to meters
of an OpenFlow instance. This table is
populated when meters are configured from
controller."
::= { hpicfOpenFlowObjects 19 }
hpicfOpenFlowInstanceMeterEntry OBJECT-TYPE
SYNTAX HpicfOpenFlowInstanceMeterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A set of objects used to retrieve details
about meters associated with an OpenFlow instance."
INDEX {
hpicfOpenFlowInstanceName,
hpicfOpenFlowInstanceMeterID
}
::= { hpicfOpenFlowInstanceMeterTable 1 }
HpicfOpenFlowInstanceMeterEntry ::=
SEQUENCE {
hpicfOpenFlowInstanceMeterID Unsigned32,
hpicfOpenFlowInstanceMeterFlowCount Unsigned32,
hpicfOpenFlowInstanceMeterInputPktCount Counter64,
hpicfOpenFlowInstanceMeterInputByteCount Counter64,
hpicfOpenFlowInstanceMeterDuration Unsigned32
}
hpicfOpenFlowInstanceMeterID OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Unique ID given to a meter."
::= { hpicfOpenFlowInstanceMeterEntry 1}
hpicfOpenFlowInstanceMeterFlowCount OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of flows on which this meter
is applied."
::= {hpicfOpenFlowInstanceMeterEntry 2}
hpicfOpenFlowInstanceMeterInputPktCount OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of packets processed by this meter."
::= {hpicfOpenFlowInstanceMeterEntry 3}
hpicfOpenFlowInstanceMeterInputByteCount OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of bytes processed by this meter."
::= {hpicfOpenFlowInstanceMeterEntry 4}
hpicfOpenFlowInstanceMeterDuration OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Duration for which this meter is active."
::= {hpicfOpenFlowInstanceMeterEntry 5}
----------------------------------------------------------
-- OpenFlow Instance Meter Band table
----------------------------------------------------------
hpicfOpenFlowInstanceMeterBandTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpicfOpenFlowInstanceMeterBandEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table that contains objects related to meter
bands for a specific meter in an OpenFlow
instance. This table is populated when meters
and their bands are configured from controller."
::= { hpicfOpenFlowObjects 20 }
hpicfOpenFlowInstanceMeterBandEntry OBJECT-TYPE
SYNTAX HpicfOpenFlowInstanceMeterBandEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A set of objects used to retrieve details
about meter bands associated with a meter and
an OpenFlow instance."
INDEX {
hpicfOpenFlowInstanceName,
hpicfOpenFlowInstanceMeterID,
hpicfOpenFlowInstanceMeterBandID
}
::= { hpicfOpenFlowInstanceMeterBandTable 1 }
HpicfOpenFlowInstanceMeterBandEntry ::=
SEQUENCE {
hpicfOpenFlowInstanceMeterBandID Unsigned32,
hpicfOpenFlowInstanceMeterBandType INTEGER,
hpicfOpenFlowInstanceMeterBandRate Unsigned32,
hpicfOpenFlowInstanceMeterBandRateUnit INTEGER,
hpicfOpenFlowInstanceMeterInBandPktCount Counter64,
hpicfOpenFlowInstanceMeterInBandByteCount Counter64,
hpicfOpenFlowInstanceMeterPrecedenceLevel Unsigned32
}
hpicfOpenFlowInstanceMeterBandID OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Unique ID given to a band in a meter."
::= {hpicfOpenFlowInstanceMeterBandEntry 1}
hpicfOpenFlowInstanceMeterBandType OBJECT-TYPE
SYNTAX INTEGER {
drop(1),
mark(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This meter band type determines how the
packets are processed."
::= { hpicfOpenFlowInstanceMeterBandEntry 2}
hpicfOpenFlowInstanceMeterBandRate OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This MIB object specifies the rate beyond
which the incoming packets would be treated
according to action specified by
hpicfOpenFlowInstanceMeterBandType MIB.
The units of this rate is determined by the
hpicfOpenFlowInstanceMeterBandRateUnit MIB"
::= {hpicfOpenFlowInstanceMeterBandEntry 3}
hpicfOpenFlowInstanceMeterBandRateUnit OBJECT-TYPE
SYNTAX INTEGER {
kbps(1),
pps(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This MIB object specifies the unit for
hpicfOpenFlowInstanceMeterBandRate MIB. The
units can be either kilobits per second or
packets per second."
::= {hpicfOpenFlowInstanceMeterBandEntry 4}
hpicfOpenFlowInstanceMeterInBandPktCount OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of packets processed by this meter."
::= {hpicfOpenFlowInstanceMeterBandEntry 5}
hpicfOpenFlowInstanceMeterInBandByteCount OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of bytes processed by this meter."
::= {hpicfOpenFlowInstanceMeterBandEntry 6}
hpicfOpenFlowInstanceMeterPrecedenceLevel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "DSCP Precedence level of the band in a meter."
::= {hpicfOpenFlowInstanceMeterBandEntry 7}
----------------------------------------------------------
-- OpenFlow Scalar Objects
----------------------------------------------------------
hpicfOpenFlowScalarObjects OBJECT IDENTIFIER ::=
{ hpicfOpenFlowObjects 21 }
hpicfOpenFlowIPControlTableUsage OBJECT-TYPE
SYNTAX Unsigned32(0..100)
UNITS "%"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object is used to specify maximum
percentage of IP control table resources that
can be used by OpenFlow. The percentage is not
a guarantee, but a maximum allowed limit."
DEFVAL { 50 }
::= { hpicfOpenFlowScalarObjects 1}
hpicfOpenFlowIPControlTableStatsRefreshRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This MIB object is used to specify the time interval at
which the hardware will be polled for statistics.
A value of '0' would mean that the hardware will no
longer be polled to update the statistics."
::= { hpicfOpenFlowScalarObjects 2}
hpicfOpenFlowIpControlTableMode OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "This MIB object specifies the OpenFlow
operation mode. In this mode, IP control table
would be advertised by an OpenFlow 1.3 instance."
::= { hpicfOpenFlowScalarObjects 9 }
hpicfOpenFlowEgressOnlyPorts OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Setting this MIB object to 'enable' will
advertise egress-only ports to the
controller."
DEFVAL { disable }
::= { hpicfOpenFlowScalarObjects 10}
-- =============================================================
-- OpenFlow - Conformance Information
-- =============================================================
hpicfOpenFlowCompliances
OBJECT IDENTIFIER ::= { hpicfOpenFlowConformance 1 }
hpicfOpenFlowGroups
OBJECT IDENTIFIER ::= { hpicfOpenFlowConformance 2 }
-- =============================================================
-- OpenFlow - units of conformance
-- =============================================================
hpicfOpenFlowGlobalConfigGroup OBJECT-GROUP
OBJECTS {
hpicfOpenFlowStatus,
hpicfOpenFlowMaxInstances,
hpicfOpenFlowMaxFlows,
hpicfOpenFlowMaxControllers
}
STATUS current
DESCRIPTION "Controls the global configuration of OpenFlow
status and allocation of policy engine resource."
::= { hpicfOpenFlowGroups 1 }
hpicfOpenFlowInstanceGroup OBJECT-GROUP
OBJECTS {
hpicfOpenFlowInstanceAdminStatus,
hpicfOpenFlowInstanceListenPortCfg,
hpicfOpenFlowInstanceListenPort,
hpicfOpenFlowInstanceListenPortIsOobm,
hpicfOpenFlowInstanceMode,
hpicfOpenFlowInstanceFlowLocationMode,
hpicfOpenFlowConnectionInterruptionMode,
hpicfOpenFlowInstanceHwRateLimit,
hpicfOpenFlowInstanceSwRateLimit,
hpicfOpenFlowInstanceDatapathID,
hpicfOpenFlowInstanceNumOfHwFlows,
hpicfOpenFlowInstanceNumOfSwFlows,
hpicfOpenFlowInstanceOperStatus,
hpicfOpenFlowInstanceMaxBackOffInterval,
hpicfOpenFlowInstanceRowStatus,
hpicfOpenFlowInstanceProbeInterval,
hpicfOpenFlowInstanceProtoVersion,
hpicfOpenFlowInstanceProtoVersionOnly,
hpicfOpenFlowInstanceNumOfSwFlowTable,
hpicfOpenFlowInstanceOperStatusReason,
hpicfOpenFlowInstanceEgressOnlyPorts,
hpicfOpenFlowInstanceCapabilities,
hpicfOpenFlowInstanceHwTableMissCount,
hpicfOpenFlowInstanceTableModel
}
STATUS deprecated
DESCRIPTION "A collection of objects used to define an
OpenFlow instance."
::= { hpicfOpenFlowGroups 2 }
hpicfOpenFlowInstanceMembershipGroup OBJECT-GROUP
OBJECTS {
hpicfOpenFlowInstanceMembershipRowStatus
}
STATUS deprecated
DESCRIPTION "An object used to associate a member to an
OpenFlow instance."
::= { hpicfOpenFlowGroups 3 }
hpicfOpenFlowControllerGroup OBJECT-GROUP
OBJECTS {
hpicfOpenFlowControllerInetAddressType,
hpicfOpenFlowControllerInetAddress,
hpicfOpenFlowControllerPort,
hpicfOpenFlowControllerInterface,
hpicfOpenFlowControllerRowStatus
}
STATUS deprecated
DESCRIPTION "A collection of objects used to define
controllers."
::= { hpicfOpenFlowGroups 4 }
hpicfOpenFlowInstanceControllerGroup OBJECT-GROUP
OBJECTS {
hpicfOpenFlowInstanceControllerStatus,
hpicfOpenFlowInstanceControllerState,
hpicfOpenFlowInstanceControllerRole,
hpicfOpenFlowInstanceControllerConnSecure,
hpicfOpenFlowInstanceControllerRowStatus
}
STATUS current
DESCRIPTION "A set of objects used to monitor the status
and state of an OpenFlow Instance and controller
connection."
::= { hpicfOpenFlowGroups 6 }
hpicfOpenFlowInstanceMeterGroup OBJECT-GROUP
OBJECTS {
hpicfOpenFlowInstanceMeterFlowCount,
hpicfOpenFlowInstanceMeterInputPktCount,
hpicfOpenFlowInstanceMeterInputByteCount,
hpicfOpenFlowInstanceMeterDuration
}
STATUS current
DESCRIPTION "A collection of objects used to retrieve
details about instance-specific meters."
::= { hpicfOpenFlowGroups 13 }
hpicfOpenFlowInstanceMeterBandGroup OBJECT-GROUP
OBJECTS {
hpicfOpenFlowInstanceMeterBandType,
hpicfOpenFlowInstanceMeterBandRate,
hpicfOpenFlowInstanceMeterBandRateUnit,
hpicfOpenFlowInstanceMeterInBandPktCount,
hpicfOpenFlowInstanceMeterInBandByteCount,
hpicfOpenFlowInstanceMeterPrecedenceLevel
}
STATUS current
DESCRIPTION "A collection of objects used to retrieve
details about meter band types."
::= { hpicfOpenFlowGroups 14 }
hpicfOpenFlowScalarsGroup OBJECT-GROUP
OBJECTS {
hpicfOpenFlowIPControlTableUsage,
hpicfOpenFlowIPControlTableStatsRefreshRate,
hpicfOpenFlowIpControlTableMode,
hpicfOpenFlowEgressOnlyPorts
}
STATUS deprecated
DESCRIPTION "Basic Scalars required for OpenFlow
implementation."
::= { hpicfOpenFlowGroups 15 }
hpicfOpenFlowInstanceGroup1 OBJECT-GROUP
OBJECTS {
hpicfOpenFlowInstanceAdminStatus,
hpicfOpenFlowInstanceListenPortCfg,
hpicfOpenFlowInstanceListenPort,
hpicfOpenFlowInstanceListenPortIsOobm,
hpicfOpenFlowInstanceMode,
hpicfOpenFlowInstanceFlowLocationMode,
hpicfOpenFlowConnectionInterruptionMode,
hpicfOpenFlowInstanceHwRateLimit,
hpicfOpenFlowInstanceSwRateLimit,
hpicfOpenFlowInstanceDatapathID,
hpicfOpenFlowInstanceNumOfHwFlows,
hpicfOpenFlowInstanceNumOfSwFlows,
hpicfOpenFlowInstanceOperStatus,
hpicfOpenFlowInstanceMaxBackOffInterval,
hpicfOpenFlowInstanceRowStatus,
hpicfOpenFlowInstanceProbeInterval,
hpicfOpenFlowInstanceProtoVersion,
hpicfOpenFlowInstanceProtoVersionOnly,
hpicfOpenFlowInstanceNumOfSwFlowTable,
hpicfOpenFlowInstanceOperStatusReason,
hpicfOpenFlowInstanceEgressOnlyPorts,
hpicfOpenFlowInstanceCapabilities,
hpicfOpenFlowInstanceHwTableMissCount,
hpicfOpenFlowInstanceTableModel,
hpicfOpenFlowInstanceMembers,
hpicfOpenFlowInstancePipelineModel,
hpicfOpenFlowInstanceDatapathDesc
}
STATUS deprecated
DESCRIPTION "A collection of objects used to define an
OpenFlow instance."
::= { hpicfOpenFlowGroups 16 }
hpicfOpenFlowScalarsGroup1 OBJECT-GROUP
OBJECTS {
hpicfOpenFlowIPControlTableUsage,
hpicfOpenFlowIPControlTableStatsRefreshRate,
hpicfOpenFlowEgressOnlyPorts
}
STATUS current
DESCRIPTION "Basic Scalars required for OpenFlow
implementation."
::= { hpicfOpenFlowGroups 17 }
hpicfOpenFlowInstanceGroup2 OBJECT-GROUP
OBJECTS {
hpicfOpenFlowInstanceAdminStatus,
hpicfOpenFlowInstanceListenPortCfg,
hpicfOpenFlowInstanceListenPort,
hpicfOpenFlowInstanceListenPortIsOobm,
hpicfOpenFlowInstanceMode,
hpicfOpenFlowInstanceFlowLocationMode,
hpicfOpenFlowConnectionInterruptionMode,
hpicfOpenFlowInstanceHwRateLimit,
hpicfOpenFlowInstanceSwRateLimit,
hpicfOpenFlowInstanceDatapathID,
hpicfOpenFlowInstanceNumOfHwFlows,
hpicfOpenFlowInstanceNumOfSwFlows,
hpicfOpenFlowInstanceOperStatus,
hpicfOpenFlowInstanceMaxBackOffInterval,
hpicfOpenFlowInstanceRowStatus,
hpicfOpenFlowInstanceProbeInterval,
hpicfOpenFlowInstanceProtoVersion,
hpicfOpenFlowInstanceProtoVersionOnly,
hpicfOpenFlowInstanceNumOfSwFlowTable,
hpicfOpenFlowInstanceOperStatusReason,
hpicfOpenFlowInstanceEgressOnlyPorts,
hpicfOpenFlowInstanceCapabilities,
hpicfOpenFlowInstanceHwTableMissCount,
hpicfOpenFlowInstanceTableModel,
hpicfOpenFlowInstanceMembers,
hpicfOpenFlowInstancePipelineModel,
hpicfOpenFlowInstanceDatapathDesc,
hpicfOpenFlowInstanceSourceMacGrpTable,
hpicfOpenFlowInstanceDestMacGrpTable
}
STATUS deprecated
DESCRIPTION "A collection of objects used to define an
OpenFlow instance."
::= { hpicfOpenFlowGroups 20 }
hpicfOpenFlowInstanceGroup3 OBJECT-GROUP
OBJECTS {
hpicfOpenFlowInstanceAdminStatus,
hpicfOpenFlowInstanceListenPortCfg,
hpicfOpenFlowInstanceListenPort,
hpicfOpenFlowInstanceListenPortIsOobm,
hpicfOpenFlowInstanceMode,
hpicfOpenFlowInstanceFlowLocationMode,
hpicfOpenFlowConnectionInterruptionMode,
hpicfOpenFlowInstanceHwRateLimit,
hpicfOpenFlowInstanceSwRateLimit,
hpicfOpenFlowInstanceDatapathID,
hpicfOpenFlowInstanceNumOfHwFlows,
hpicfOpenFlowInstanceNumOfSwFlows,
hpicfOpenFlowInstanceOperStatus,
hpicfOpenFlowInstanceMaxBackOffInterval,
hpicfOpenFlowInstanceRowStatus,
hpicfOpenFlowInstanceProbeInterval,
hpicfOpenFlowInstanceProtoVersion,
hpicfOpenFlowInstanceProtoVersionOnly,
hpicfOpenFlowInstanceNumOfSwFlowTable,
hpicfOpenFlowInstanceOperStatusReason,
hpicfOpenFlowInstanceEgressOnlyPorts,
hpicfOpenFlowInstanceCapabilities,
hpicfOpenFlowInstanceHwTableMissCount,
hpicfOpenFlowInstanceTableModel,
hpicfOpenFlowInstanceMembers,
hpicfOpenFlowInstancePipelineModel,
hpicfOpenFlowInstanceDatapathDesc,
hpicfOpenFlowInstanceSourceMacGrpTable,
hpicfOpenFlowInstanceDestMacGrpTable,
hpicfOpenFlowInstanceMissRuleDefaultAction,
hpicfOpenFlowInstanceOverrideProtocol,
hpicfOpenFlowInstancePktInVlanTagging
}
STATUS current
DESCRIPTION "A collection of objects used to define an
OpenFlow instance."
::= { hpicfOpenFlowGroups 21 }
hpicfOpenFlowControllerGroup1 OBJECT-GROUP
OBJECTS {
hpicfOpenFlowControllerInetAddressType,
hpicfOpenFlowControllerInetAddress,
hpicfOpenFlowControllerPort,
hpicfOpenFlowControllerInterface,
hpicfOpenFlowControllerRowStatus,
hpicfOpenFlowControllerSourceAddressType,
hpicfOpenFlowControllerSourceAddress
}
STATUS current
DESCRIPTION "A collection of objects used to define
controllers."
::= { hpicfOpenFlowGroups 22 }
-- =============================================================
-- OpenFlow - Compliance Statements
-- =============================================================
hpicfOpenFlowCompliance MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION "This compliance statement is for devices
supporting OpenFlow. The basic support for
OpenFlow requires implementation of the
objects listed in the mandatory groups."
MODULE
MANDATORY-GROUPS {
hpicfOpenFlowGlobalConfigGroup,
hpicfOpenFlowInstanceGroup,
hpicfOpenFlowInstanceMembershipGroup,
hpicfOpenFlowControllerGroup
}
GROUP hpicfOpenFlowInstanceControllerGroup
DESCRIPTION "This group is optional whose objects are used
to monitor the status and state of connection
between an OpenFlow instance and a controller."
GROUP hpicfOpenFlowInstanceMeterGroup
DESCRIPTION "A collection of objects used to retrieve
details about instance-specific meters."
GROUP hpicfOpenFlowInstanceMeterBandGroup
DESCRIPTION "A collection of objects used to retrieve
details about meter band types."
GROUP hpicfOpenFlowScalarsGroup
DESCRIPTION "A collection of scalar objects."
::= { hpicfOpenFlowCompliances 1 }
hpicfOpenFlowCompliance1 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION "This compliance statement is for devices
supporting OpenFlow. The basic support for
OpenFlow requires implementation of the
objects listed in the mandatory groups."
MODULE
MANDATORY-GROUPS {
hpicfOpenFlowGlobalConfigGroup,
hpicfOpenFlowInstanceGroup1,
hpicfOpenFlowControllerGroup
}
GROUP hpicfOpenFlowInstanceControllerGroup
DESCRIPTION "This group is optional whose objects are used
to monitor the status and state of connection
between an OpenFlow instance and a controller."
GROUP hpicfOpenFlowInstanceMeterGroup
DESCRIPTION "A collection of objects used to retrieve
details about instance-specific meters."
GROUP hpicfOpenFlowInstanceMeterBandGroup
DESCRIPTION "A collection of objects used to retrieve
details about meter band types."
GROUP hpicfOpenFlowScalarsGroup1
DESCRIPTION "A collection of scalar objects."
::= { hpicfOpenFlowCompliances 2 }
hpicfOpenFlowCompliance2 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION "This compliance statement is for devices
supporting OpenFlow. The basic support for
OpenFlow requires implementation of the
objects listed in the mandatory groups."
MODULE
MANDATORY-GROUPS {
hpicfOpenFlowGlobalConfigGroup,
hpicfOpenFlowInstanceGroup2,
hpicfOpenFlowControllerGroup
}
GROUP hpicfOpenFlowInstanceControllerGroup
DESCRIPTION "This group is optional whose objects are used
to monitor the status and state of connection
between an OpenFlow instance and a controller."
GROUP hpicfOpenFlowInstanceMeterGroup
DESCRIPTION "A collection of objects used to retrieve
details about instance-specific meters."
GROUP hpicfOpenFlowInstanceMeterBandGroup
DESCRIPTION "A collection of objects used to retrieve
details about meter band types."
GROUP hpicfOpenFlowScalarsGroup1
DESCRIPTION "A collection of scalar objects."
::= { hpicfOpenFlowCompliances 3 }
hpicfOpenFlowCompliance3 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION "This compliance statement is for devices
supporting OpenFlow. The basic support for
OpenFlow requires implementation of the
objects listed in the mandatory groups."
MODULE
MANDATORY-GROUPS {
hpicfOpenFlowGlobalConfigGroup,
hpicfOpenFlowInstanceGroup3,
hpicfOpenFlowControllerGroup
}
GROUP hpicfOpenFlowInstanceControllerGroup
DESCRIPTION "This group is optional whose objects are used
to monitor the status and state of connection
between an OpenFlow instance and a controller."
GROUP hpicfOpenFlowInstanceMeterGroup
DESCRIPTION "A collection of objects used to retrieve
details about instance-specific meters."
GROUP hpicfOpenFlowInstanceMeterBandGroup
DESCRIPTION "A collection of objects used to retrieve
details about meter band types."
GROUP hpicfOpenFlowScalarsGroup1
DESCRIPTION "A collection of scalar objects."
::= { hpicfOpenFlowCompliances 4 }
hpicfOpenFlowCompliance4 MODULE-COMPLIANCE
STATUS current
DESCRIPTION "This compliance statement is for devices
supporting OpenFlow. The basic support for
OpenFlow requires implementation of the
objects listed in the mandatory groups."
MODULE
MANDATORY-GROUPS {
hpicfOpenFlowGlobalConfigGroup,
hpicfOpenFlowInstanceGroup3,
hpicfOpenFlowControllerGroup1
}
GROUP hpicfOpenFlowInstanceControllerGroup
DESCRIPTION "This group is optional whose objects are used
to monitor the status and state of connection
between an OpenFlow instance and a controller."
GROUP hpicfOpenFlowInstanceMeterGroup
DESCRIPTION "A collection of objects used to retrieve
details about instance-specific meters."
GROUP hpicfOpenFlowInstanceMeterBandGroup
DESCRIPTION "A collection of objects used to retrieve
details about meter band types."
GROUP hpicfOpenFlowScalarsGroup1
DESCRIPTION "A collection of scalar objects."
::= { hpicfOpenFlowCompliances 5 }