-- (C) COPYRIGHT HEWLETT-PACKARD COMPANY 2000.
|
||
--
|
||
-- HP Color LaserJet 8550 Printer Specific MIB.
|
||
-- Hewlett-Packard Company Confidential
|
||
--
|
||
-- Hewlett-Packard makes no warranty of any kind with
|
||
-- regard to this manual, including, but not limited
|
||
-- to, the implied warranties of merchantability and
|
||
-- fitness for a particular purpose. Hewlett Packard
|
||
-- shall not be held liable for errors contained herein
|
||
-- or direct, indirect, special, incidental, or
|
||
-- consequential damages in connection with the
|
||
-- furnishing, performance, or use of this material.
|
||
--
|
||
-- Generated on May 22, 2000.
|
||
--
|
||
-- Company names and product names mentioned herein may be
|
||
-- trademarks, and/or registered trademarks of their respective
|
||
-- companies.
|
||
--
|
||
-- This MIB describes all the printer model specific
|
||
-- objects supported by the HP LaserJet 8550 printer
|
||
-- when networked connected using a JetDirect print
|
||
-- server.
|
||
--
|
||
-- For interal and external use.
|
||
--
|
||
-- This MIB describes all the printer model specific
|
||
-- objects supported by the HP Color LaserJet 8550 printer
|
||
-- when networked connected using a JetDirect print
|
||
-- server.
|
||
--
|
||
-- The following MIB also contain objects supported
|
||
-- by a JetDirect connected HP Color LaserJet 8550 printer:
|
||
--
|
||
-- rfc 1213 MIB II
|
||
--
|
||
-- This MIB complies with the following RFCs:
|
||
--
|
||
-- rfc 1157 Simple Network Management Protocol
|
||
-- rfc 1155 Structure of Management Information
|
||
--
|
||
-- Notes:
|
||
--
|
||
-- 1) Proprietary Objects containing a string which are defined in this MIB use the
|
||
-- first two bytes to hold the symbol set used to encode the string.
|
||
-- The Roman-8 symbol set has a hex encoding of 0x0115. Other
|
||
-- symbol sets are listed in the PCL 5 Comparison Guide in table
|
||
-- C-1 Symbol Set Values. Standard Printer MIB (prt...objects) and Host Resources
|
||
-- MIB (hr...objects) strings do not contain symbol set information.
|
||
--
|
||
-- 2) Some of the objects included are only supported if an accessory
|
||
-- is installed. These accessories include:
|
||
-- MIO/EIO based accessories
|
||
-- SIMM/DIMM based accessories
|
||
-- Paper handling accessories
|
||
--
|
||
--
|
||
CLJ8550-MIB DEFINITIONS ::= BEGIN
|
||
|
||
hp OBJECT IDENTIFIER ::= { iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) 11}
|
||
dm OBJECT IDENTIFIER ::= { hp nm(2) hpsystem(3) net-peripheral(9) netdm(4) 2}
|
||
|
||
DisplayString ::= OCTET STRING
|
||
|
||
device OBJECT IDENTIFIER ::= { dm 1 }
|
||
system OBJECT IDENTIFIER ::= { device 1 }
|
||
settings-system OBJECT IDENTIFIER ::= { system 1 }
|
||
status-system OBJECT IDENTIFIER ::= { system 2 }
|
||
background-message OBJECT IDENTIFIER ::= { status-system 37 }
|
||
background-message1 OBJECT IDENTIFIER ::= { background-message 1 }
|
||
background-message2 OBJECT IDENTIFIER ::= { background-message 2 }
|
||
id OBJECT IDENTIFIER ::= { system 3 }
|
||
interface OBJECT IDENTIFIER ::= { system 4 }
|
||
simm OBJECT IDENTIFIER ::= { interface 1 }
|
||
simm1 OBJECT IDENTIFIER ::= { simm 1 }
|
||
simm2 OBJECT IDENTIFIER ::= { simm 2 }
|
||
simm3 OBJECT IDENTIFIER ::= { simm 3 }
|
||
simm4 OBJECT IDENTIFIER ::= { simm 4 }
|
||
simm5 OBJECT IDENTIFIER ::= { simm 5 }
|
||
simm6 OBJECT IDENTIFIER ::= { simm 6 }
|
||
simm7 OBJECT IDENTIFIER ::= { simm 7 }
|
||
simm8 OBJECT IDENTIFIER ::= { simm 8 }
|
||
mio OBJECT IDENTIFIER ::= { interface 3 }
|
||
mio1 OBJECT IDENTIFIER ::= { mio 1 }
|
||
mio2 OBJECT IDENTIFIER ::= { mio 2 }
|
||
phd OBJECT IDENTIFIER ::= { interface 5 }
|
||
phd1 OBJECT IDENTIFIER ::= { phd 1 }
|
||
phd2 OBJECT IDENTIFIER ::= { phd 2 }
|
||
phd3 OBJECT IDENTIFIER ::= { phd 3 }
|
||
phd4 OBJECT IDENTIFIER ::= { phd 4 }
|
||
phd5 OBJECT IDENTIFIER ::= { phd 5 }
|
||
phd6 OBJECT IDENTIFIER ::= { phd 6 }
|
||
test OBJECT IDENTIFIER ::= { system 5 }
|
||
job OBJECT IDENTIFIER ::= { system 6 }
|
||
settings-job OBJECT IDENTIFIER ::= { job 1 }
|
||
active-print-jobs OBJECT IDENTIFIER ::= { job 2 }
|
||
job-being-parsed OBJECT IDENTIFIER ::= { active-print-jobs 1 }
|
||
job-info OBJECT IDENTIFIER ::= { job 5 }
|
||
job-info-attribute OBJECT IDENTIFIER ::= { job-info 23 }
|
||
held-job OBJECT IDENTIFIER ::= { job 7 }
|
||
held-job-info OBJECT IDENTIFIER ::= { held-job 1 }
|
||
held-job-control OBJECT IDENTIFIER ::= { held-job 2 }
|
||
file-system OBJECT IDENTIFIER ::= { system 10 }
|
||
settings-file-system OBJECT IDENTIFIER ::= { file-system 1 }
|
||
status-file-system OBJECT IDENTIFIER ::= { file-system 2 }
|
||
file-systems OBJECT IDENTIFIER ::= { file-system 3 }
|
||
file-system2 OBJECT IDENTIFIER ::= { file-systems 2 }
|
||
errorlog OBJECT IDENTIFIER ::= { system 11 }
|
||
error1 OBJECT IDENTIFIER ::= { errorlog 1 }
|
||
error2 OBJECT IDENTIFIER ::= { errorlog 2 }
|
||
error3 OBJECT IDENTIFIER ::= { errorlog 3 }
|
||
error4 OBJECT IDENTIFIER ::= { errorlog 4 }
|
||
error5 OBJECT IDENTIFIER ::= { errorlog 5 }
|
||
error6 OBJECT IDENTIFIER ::= { errorlog 6 }
|
||
error7 OBJECT IDENTIFIER ::= { errorlog 7 }
|
||
error8 OBJECT IDENTIFIER ::= { errorlog 8 }
|
||
error9 OBJECT IDENTIFIER ::= { errorlog 9 }
|
||
error10 OBJECT IDENTIFIER ::= { errorlog 10 }
|
||
error11 OBJECT IDENTIFIER ::= { errorlog 11 }
|
||
error12 OBJECT IDENTIFIER ::= { errorlog 12 }
|
||
error13 OBJECT IDENTIFIER ::= { errorlog 13 }
|
||
error14 OBJECT IDENTIFIER ::= { errorlog 14 }
|
||
error15 OBJECT IDENTIFIER ::= { errorlog 15 }
|
||
error16 OBJECT IDENTIFIER ::= { errorlog 16 }
|
||
error17 OBJECT IDENTIFIER ::= { errorlog 17 }
|
||
error18 OBJECT IDENTIFIER ::= { errorlog 18 }
|
||
error19 OBJECT IDENTIFIER ::= { errorlog 19 }
|
||
error20 OBJECT IDENTIFIER ::= { errorlog 20 }
|
||
error21 OBJECT IDENTIFIER ::= { errorlog 21 }
|
||
error22 OBJECT IDENTIFIER ::= { errorlog 22 }
|
||
error23 OBJECT IDENTIFIER ::= { errorlog 23 }
|
||
error24 OBJECT IDENTIFIER ::= { errorlog 24 }
|
||
error25 OBJECT IDENTIFIER ::= { errorlog 25 }
|
||
error26 OBJECT IDENTIFIER ::= { errorlog 26 }
|
||
error27 OBJECT IDENTIFIER ::= { errorlog 27 }
|
||
error28 OBJECT IDENTIFIER ::= { errorlog 28 }
|
||
error29 OBJECT IDENTIFIER ::= { errorlog 29 }
|
||
error30 OBJECT IDENTIFIER ::= { errorlog 30 }
|
||
error31 OBJECT IDENTIFIER ::= { errorlog 31 }
|
||
error32 OBJECT IDENTIFIER ::= { errorlog 32 }
|
||
error33 OBJECT IDENTIFIER ::= { errorlog 33 }
|
||
error34 OBJECT IDENTIFIER ::= { errorlog 34 }
|
||
error35 OBJECT IDENTIFIER ::= { errorlog 35 }
|
||
error36 OBJECT IDENTIFIER ::= { errorlog 36 }
|
||
error37 OBJECT IDENTIFIER ::= { errorlog 37 }
|
||
error38 OBJECT IDENTIFIER ::= { errorlog 38 }
|
||
error39 OBJECT IDENTIFIER ::= { errorlog 39 }
|
||
error40 OBJECT IDENTIFIER ::= { errorlog 40 }
|
||
error41 OBJECT IDENTIFIER ::= { errorlog 41 }
|
||
error42 OBJECT IDENTIFIER ::= { errorlog 42 }
|
||
error43 OBJECT IDENTIFIER ::= { errorlog 43 }
|
||
error44 OBJECT IDENTIFIER ::= { errorlog 44 }
|
||
error45 OBJECT IDENTIFIER ::= { errorlog 45 }
|
||
error46 OBJECT IDENTIFIER ::= { errorlog 46 }
|
||
error47 OBJECT IDENTIFIER ::= { errorlog 47 }
|
||
error48 OBJECT IDENTIFIER ::= { errorlog 48 }
|
||
error49 OBJECT IDENTIFIER ::= { errorlog 49 }
|
||
error50 OBJECT IDENTIFIER ::= { errorlog 50 }
|
||
remote-procedure-call OBJECT IDENTIFIER ::= { system 13 }
|
||
settings-rpc OBJECT IDENTIFIER ::= { remote-procedure-call 1 }
|
||
status-rpc OBJECT IDENTIFIER ::= { remote-procedure-call 2 }
|
||
rpc-services OBJECT IDENTIFIER ::= { remote-procedure-call 3 }
|
||
nfs-server OBJECT IDENTIFIER ::= { rpc-services 2 }
|
||
settings-nfs-server OBJECT IDENTIFIER ::= { nfs-server 1 }
|
||
status-nfs-server OBJECT IDENTIFIER ::= { nfs-server 2 }
|
||
rpc-bind OBJECT IDENTIFIER ::= { rpc-services 3 }
|
||
settings-rpc-bind OBJECT IDENTIFIER ::= { rpc-bind 1 }
|
||
status-rpc-bind OBJECT IDENTIFIER ::= { rpc-bind 2 }
|
||
xport-interface OBJECT IDENTIFIER ::= { system 14 }
|
||
status-xip OBJECT IDENTIFIER ::= { xport-interface 2 }
|
||
source-subsystem OBJECT IDENTIFIER ::= { device 2 }
|
||
io OBJECT IDENTIFIER ::= { source-subsystem 1 }
|
||
settings-io OBJECT IDENTIFIER ::= { io 1 }
|
||
ports OBJECT IDENTIFIER ::= { io 3 }
|
||
port1 OBJECT IDENTIFIER ::= { ports 1 }
|
||
processing-subsystem OBJECT IDENTIFIER ::= { device 3 }
|
||
pdl OBJECT IDENTIFIER ::= { processing-subsystem 3 }
|
||
settings-pdl OBJECT IDENTIFIER ::= { pdl 1 }
|
||
status-pdl OBJECT IDENTIFIER ::= { pdl 2 }
|
||
pdl-pcl OBJECT IDENTIFIER ::= { pdl 3 }
|
||
pdl-postscript OBJECT IDENTIFIER ::= { pdl 4 }
|
||
pjl OBJECT IDENTIFIER ::= { processing-subsystem 5 }
|
||
jetsend-proc-sub OBJECT IDENTIFIER ::= { processing-subsystem 8 }
|
||
settings-jetsend OBJECT IDENTIFIER ::= { jetsend-proc-sub 1 }
|
||
jetsend-contact OBJECT IDENTIFIER ::= { jetsend-proc-sub 3 }
|
||
settings-jetsend-contact OBJECT IDENTIFIER ::= { jetsend-contact 1 }
|
||
destination-subsystem OBJECT IDENTIFIER ::= { device 4 }
|
||
print-engine OBJECT IDENTIFIER ::= { destination-subsystem 1 }
|
||
status-prt-eng OBJECT IDENTIFIER ::= { print-engine 2 }
|
||
intray OBJECT IDENTIFIER ::= { print-engine 3 }
|
||
settings-intray OBJECT IDENTIFIER ::= { intray 1 }
|
||
intrays OBJECT IDENTIFIER ::= { intray 3 }
|
||
intray1 OBJECT IDENTIFIER ::= { intrays 1 }
|
||
intray2 OBJECT IDENTIFIER ::= { intrays 2 }
|
||
intray3 OBJECT IDENTIFIER ::= { intrays 3 }
|
||
intray4 OBJECT IDENTIFIER ::= { intrays 4 }
|
||
intray5 OBJECT IDENTIFIER ::= { intrays 5 }
|
||
outbin OBJECT IDENTIFIER ::= { print-engine 4 }
|
||
settings-outbin OBJECT IDENTIFIER ::= { outbin 1 }
|
||
outbins OBJECT IDENTIFIER ::= { outbin 3 }
|
||
outbin1 OBJECT IDENTIFIER ::= { outbins 1 }
|
||
outbin2 OBJECT IDENTIFIER ::= { outbins 2 }
|
||
outbin3 OBJECT IDENTIFIER ::= { outbins 3 }
|
||
outbin4 OBJECT IDENTIFIER ::= { outbins 4 }
|
||
outbin5 OBJECT IDENTIFIER ::= { outbins 5 }
|
||
outbin6 OBJECT IDENTIFIER ::= { outbins 6 }
|
||
outbin7 OBJECT IDENTIFIER ::= { outbins 7 }
|
||
outbin8 OBJECT IDENTIFIER ::= { outbins 8 }
|
||
outbin9 OBJECT IDENTIFIER ::= { outbins 9 }
|
||
outbin10 OBJECT IDENTIFIER ::= { outbins 10 }
|
||
outbin11 OBJECT IDENTIFIER ::= { outbins 11 }
|
||
marking-agent OBJECT IDENTIFIER ::= { print-engine 5 }
|
||
settings-marking-agent OBJECT IDENTIFIER ::= { marking-agent 1 }
|
||
imaging OBJECT IDENTIFIER ::= { print-engine 6 }
|
||
ph OBJECT IDENTIFIER ::= { print-engine 7 }
|
||
ph-devices OBJECT IDENTIFIER ::= { ph 3 }
|
||
ph2 OBJECT IDENTIFIER ::= { ph-devices 2 }
|
||
ph3 OBJECT IDENTIFIER ::= { ph-devices 3 }
|
||
print-media OBJECT IDENTIFIER ::= { print-engine 8 }
|
||
settings-print-media OBJECT IDENTIFIER ::= { print-media 1 }
|
||
media-info OBJECT IDENTIFIER ::= { print-media 3 }
|
||
media1 OBJECT IDENTIFIER ::= { media-info 1 }
|
||
media2 OBJECT IDENTIFIER ::= { media-info 2 }
|
||
media3 OBJECT IDENTIFIER ::= { media-info 3 }
|
||
media4 OBJECT IDENTIFIER ::= { media-info 4 }
|
||
media5 OBJECT IDENTIFIER ::= { media-info 5 }
|
||
media6 OBJECT IDENTIFIER ::= { media-info 6 }
|
||
media7 OBJECT IDENTIFIER ::= { media-info 7 }
|
||
media8 OBJECT IDENTIFIER ::= { media-info 8 }
|
||
media9 OBJECT IDENTIFIER ::= { media-info 9 }
|
||
media10 OBJECT IDENTIFIER ::= { media-info 10 }
|
||
media11 OBJECT IDENTIFIER ::= { media-info 11 }
|
||
media12 OBJECT IDENTIFIER ::= { media-info 12 }
|
||
media13 OBJECT IDENTIFIER ::= { media-info 13 }
|
||
media14 OBJECT IDENTIFIER ::= { media-info 14 }
|
||
media15 OBJECT IDENTIFIER ::= { media-info 15 }
|
||
tables OBJECT IDENTIFIER ::= { device 7 }
|
||
channel-table OBJECT IDENTIFIER ::= { tables 2 }
|
||
channel-entry OBJECT IDENTIFIER ::= { channel-table 1 }
|
||
resource-manager OBJECT IDENTIFIER ::= { system 12 }
|
||
mass-storage-resources OBJECT IDENTIFIER ::= { resource-manager 3 }
|
||
hrm OBJECT IDENTIFIER ::= { dm 3 }
|
||
hrDevice OBJECT IDENTIFIER ::= { hrm 3 }
|
||
hrDiskStorageTable OBJECT IDENTIFIER ::= { hrDevice 6 }
|
||
hrDiskStorageEntry OBJECT IDENTIFIER ::= { hrDiskStorageTable 1 }
|
||
hrPartitionTable OBJECT IDENTIFIER ::= { hrDevice 7 }
|
||
hrPartitionEntry OBJECT IDENTIFIER ::= { hrPartitionTable 1 }
|
||
hrFSTable OBJECT IDENTIFIER ::= { hrDevice 8 }
|
||
hrFSEntry OBJECT IDENTIFIER ::= { hrFSTable 1 }
|
||
hrStorage OBJECT IDENTIFIER ::= { hrm 2 }
|
||
hrStorageTable OBJECT IDENTIFIER ::= { hrStorage 3 }
|
||
hrStorageEntry OBJECT IDENTIFIER ::= { hrStorageTable 1 }
|
||
hrDeviceTable OBJECT IDENTIFIER ::= { hrDevice 2 }
|
||
hrDeviceEntry OBJECT IDENTIFIER ::= { hrDeviceTable 1 }
|
||
hrPrinterTable OBJECT IDENTIFIER ::= { hrDevice 5 }
|
||
hrPrinterEntry OBJECT IDENTIFIER ::= { hrPrinterTable 1 }
|
||
channel OBJECT IDENTIFIER ::= { device 6 }
|
||
channelTable OBJECT IDENTIFIER ::= { channel 3 }
|
||
channelEntry OBJECT IDENTIFIER ::= { channelTable 1 }
|
||
print-engine-test OBJECT IDENTIFIER ::= { print-engine 9 }
|
||
printmib OBJECT IDENTIFIER ::= { dm 2 }
|
||
prtGeneral OBJECT IDENTIFIER ::= { printmib 5 }
|
||
prtGeneralTable OBJECT IDENTIFIER ::= { prtGeneral 1 }
|
||
prtGeneralEntry OBJECT IDENTIFIER ::= { prtGeneralTable 1 }
|
||
prtCover OBJECT IDENTIFIER ::= { printmib 6 }
|
||
prtCoverTable OBJECT IDENTIFIER ::= { prtCover 1 }
|
||
prtCoverEntry OBJECT IDENTIFIER ::= { prtCoverTable 1 }
|
||
prtLocalization OBJECT IDENTIFIER ::= { printmib 7 }
|
||
prtLocalizationTable OBJECT IDENTIFIER ::= { prtLocalization 1 }
|
||
prtLocalizationEntry OBJECT IDENTIFIER ::= { prtLocalizationTable 1 }
|
||
prtStorageRefTable OBJECT IDENTIFIER ::= { prtGeneral 2 }
|
||
prtStorageRefEntry OBJECT IDENTIFIER ::= { prtStorageRefTable 1 }
|
||
prtDeviceRefTable OBJECT IDENTIFIER ::= { prtGeneral 3 }
|
||
prtDeviceRefEntry OBJECT IDENTIFIER ::= { prtDeviceRefTable 1 }
|
||
prtInput OBJECT IDENTIFIER ::= { printmib 8 }
|
||
prtInputTable OBJECT IDENTIFIER ::= { prtInput 2 }
|
||
prtInputEntry OBJECT IDENTIFIER ::= { prtInputTable 1 }
|
||
prtOutput OBJECT IDENTIFIER ::= { printmib 9 }
|
||
prtOutputTable OBJECT IDENTIFIER ::= { prtOutput 2 }
|
||
prtOutputEntry OBJECT IDENTIFIER ::= { prtOutputTable 1 }
|
||
prtMarker OBJECT IDENTIFIER ::= { printmib 10 }
|
||
prtMarkerTable OBJECT IDENTIFIER ::= { prtMarker 2 }
|
||
prtMarkerEntry OBJECT IDENTIFIER ::= { prtMarkerTable 1 }
|
||
prtMarkerSupplies OBJECT IDENTIFIER ::= { printmib 11 }
|
||
prtMarkerSuppliesTable OBJECT IDENTIFIER ::= { prtMarkerSupplies 1 }
|
||
prtMarkerSuppliesEntry OBJECT IDENTIFIER ::= { prtMarkerSuppliesTable 1 }
|
||
prtMediaPath OBJECT IDENTIFIER ::= { printmib 13 }
|
||
prtMediaPathTable OBJECT IDENTIFIER ::= { prtMediaPath 4 }
|
||
prtMediaPathEntry OBJECT IDENTIFIER ::= { prtMediaPathTable 1 }
|
||
prtChannel OBJECT IDENTIFIER ::= { printmib 14 }
|
||
prtChannelTable OBJECT IDENTIFIER ::= { prtChannel 1 }
|
||
prtChannelEntry OBJECT IDENTIFIER ::= { prtChannelTable 1 }
|
||
prtInterpreter OBJECT IDENTIFIER ::= { printmib 15 }
|
||
prtInterpreterTable OBJECT IDENTIFIER ::= { prtInterpreter 1 }
|
||
prtInterpreterEntry OBJECT IDENTIFIER ::= { prtInterpreterTable 1 }
|
||
prtConsoleDisplayBuffer OBJECT IDENTIFIER ::= { printmib 16 }
|
||
prtConsoleDisplayBufferTable OBJECT IDENTIFIER ::= { prtConsoleDisplayBuffer 5 }
|
||
prtConsoleDisplayBufferEntry OBJECT IDENTIFIER ::= { prtConsoleDisplayBufferTable 1 }
|
||
prtConsoleLights OBJECT IDENTIFIER ::= { printmib 17 }
|
||
prtConsoleLightTable OBJECT IDENTIFIER ::= { prtConsoleLights 6 }
|
||
prtConsoleLightEntry OBJECT IDENTIFIER ::= { prtConsoleLightTable 1 }
|
||
prtAlert OBJECT IDENTIFIER ::= { printmib 18 }
|
||
prtAlertTable OBJECT IDENTIFIER ::= { prtAlert 1 }
|
||
prtAlertEntry OBJECT IDENTIFIER ::= { prtAlertTable 1 }
|
||
|
||
|
||
energy-star OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or changes the Energy Star sleep value. If the
|
||
value is greater than zero, then the device will go into
|
||
energy saving sleep mode after the print engine has been
|
||
idle for the number of seconds specified by this object.
|
||
A value of zero means Energy Star is disabled and the
|
||
device will not go to sleep based on print engine idle
|
||
time. The value must be non-negative.
|
||
Additional information:
|
||
Returns or changes the Energy Star sleep value.
|
||
The device will go into energy saving sleep
|
||
mode after the print engine has been idle for
|
||
the number of seconds specified by this
|
||
object. Color LaserJet8550 supports values of 10, 1800,
|
||
3600, 10800, 28800.
|
||
Setting to an unsupported value causes
|
||
the printer to substitute a value (listed
|
||
below) and to return <noError>
|
||
status.
|
||
The values for normal operation are as follow:
|
||
>=0 and <= 15 snap to 10
|
||
>= 16 and <= 2699 snap to 1800 (30 minutes)
|
||
>= 2700 and <= 5399 snap to 3600 (60 minutes)
|
||
>= 5400 and <= 16199 snap to 10800 (180 minutes)
|
||
>= 16200 snap to 28800 (480 minutes) "
|
||
::= { settings-system 1 }
|
||
|
||
|
||
sleep-mode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eFalse(1),
|
||
eTrue(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns eTrue if the device is in energy saving sleep
|
||
mode, otherwise returns eFalse. Setting SLEEP-MODE to
|
||
eFalse causes the device to wake up, if it is in sleep
|
||
mode. Setting SLEEP-MODE to eTrue causes the device to
|
||
go into sleep mode.
|
||
Additional information:
|
||
Setting SLEEP-MODE to eTrue causes the device
|
||
to go into sleep mode.
|
||
Setting this object to eTrue while printer is
|
||
awake will not change the printer's current state
|
||
and will return <genErr>
|
||
status.
|
||
Setting this object to eTrue while printer is
|
||
already in the Sleep Mode will not change the
|
||
printer's current state and will return <noError> status.
|
||
Setting this object to eFalse while the printer is
|
||
asleep causes the device to wake up.
|
||
Setting eFalse while printer is already awake
|
||
will not change the printer's
|
||
current state and will return <noError> status."
|
||
::= { settings-system 2 }
|
||
|
||
|
||
on-off-line OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eOnline(1),
|
||
eOffline(2),
|
||
eOfflineAtEndOfJob(3)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"To bring the PDL processing sub-system on or off line.
|
||
If the device is a printer, then the printer does not
|
||
process print job data when the printer is off line.
|
||
PML communication persists.
|
||
Additional information:
|
||
When the printer is in the Offline state,
|
||
printing will stop as soon as possible (no more sheets
|
||
of media are pulled from input trays). All I/O
|
||
communication continues (no change from the Online
|
||
state).
|
||
|
||
Setting to eOnline has the following affect:
|
||
Printer will immediately go to or remain in the Online
|
||
state; <noError> status is returned.
|
||
If the printer's current state
|
||
is Offline with a pending error condition that
|
||
prevents the printer from going to the Online
|
||
state, the printer will remain in the Offline state;
|
||
<genErr> status is returned.
|
||
Setting to eOffline has the following affect:
|
||
Printer will immediately go to or remain in the
|
||
Offline state; <noError> status is returned.
|
||
If pages are being printed, those pages will complete
|
||
with the printer in the Offline state.
|
||
|
||
Setting to eOfflineAtEndOfJob has the following
|
||
affect:
|
||
If not in a job or already in the Offline state, the
|
||
printer will immediately go to or remain in the
|
||
Offline state; <noError> status is returned.
|
||
If printing and the current state is Online, the
|
||
printer will remain in the Online state, with the
|
||
value of this object as eOfflineAtEndOfJob, until the
|
||
end of the job; <noError> status is returned. At the end of
|
||
the job, the printer goes to the Offline state and the
|
||
value of this object becomes eOffline. During the
|
||
eOffine state, the printer will still rip and process
|
||
jobs.
|
||
Setting this object to eOffline or eOnline before the
|
||
end of the job causes the action for that value to be
|
||
taken immediately."
|
||
::= { status-system 5 }
|
||
|
||
|
||
continue OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eInitiateAction(1)
|
||
}
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A device can support a class of errors called
|
||
continuable errors. When a continuable error is
|
||
encountered, the device requires a continue event to
|
||
occur before the device will continue operation. One
|
||
continue event is setting the CONTINUE object to
|
||
eInitiateAction. Devices can support other continue
|
||
events, like auto-continue. A continue event causes the
|
||
continuable error to be acknowledged, thus allowing the
|
||
device to continue. Each device needs to list the
|
||
continuable errors. If the device doesn't currently
|
||
have an unacknowledged continuable error, the response
|
||
will contain <genErr>.
|
||
Additional information:
|
||
Since Color LaserJet8550 does not have a CONTINUE key,
|
||
the GO key is used to perform the continue operation
|
||
at the control panel."
|
||
::= { status-system 6 }
|
||
|
||
|
||
auto-continue OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eOn(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates if the device will automatically continue
|
||
after encountering a continuable error. If AUTO-
|
||
CONTINUE is set to eOn, the device will automatically
|
||
generate continue event to acknowledge continuable
|
||
errors. If AUTO-CONTINUE is set to eOff, then some
|
||
other continue event will have to acknowledge the
|
||
continuable error.
|
||
Additional information:
|
||
Indicates if the device will automatically continue
|
||
after encountering a continuable error. If AUTO-CONTINUE
|
||
is set to eOn (AUTO-CONTINUE is always on for Color LaserJet8550), the
|
||
device will automatically generate continue event to
|
||
acknowledge continuable errors."
|
||
::= { status-system 7 }
|
||
|
||
|
||
job-input-auto-continue-timeout OBJECT-TYPE
|
||
SYNTAX INTEGER(-1..3600)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The number of seconds the device waits after a job
|
||
related continuable error occurs before automatically
|
||
continuing. An example job related continuable error is
|
||
the job requesting a media size that is not available.
|
||
After the timeout expires, the device will continue
|
||
processing the job as if a continue event occurred, such
|
||
as the front panel continue key being pressed. If the
|
||
value is -1, the device does not automatically continue
|
||
after a job related continuable error occurs. If the
|
||
value is 0, the device immediately continues. If the
|
||
value is greater than 0, the value represents the
|
||
timeout value in seconds.
|
||
Additional information:
|
||
This object is used only for media requests
|
||
(size and/or name).
|
||
Color LaserJet8550 supports any value in the range of -1 to 3600.
|
||
Setting to a value outside of that range causes
|
||
the printer to substitute a value (listed
|
||
below) and to return <noError>
|
||
status.
|
||
The values are as follow:
|
||
<-1 snaps to -1
|
||
>3600 snaps to 3600 (60 minutes)
|
||
The action that occurs when this timeout expires is
|
||
explained by JOB-INPUT-AUTO-CONTINUE-MODE. It is not
|
||
the same as the CONTINUE object being set to
|
||
eInitiateAction or the Go key being pressed on
|
||
the control panel. See
|
||
the CONTINUE object description for information on the
|
||
actions that occur for those conditions."
|
||
::= { status-system 35 }
|
||
|
||
|
||
job-input-auto-continue-mode OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or sets the device behavior when the desired
|
||
media is not currently available.
|
||
cCancelJob - The device cancels the job. The device
|
||
POS should explain what happens if this item is not the
|
||
only item in the collection.
|
||
cAutoMediaSizeOverride - The device is allowed to
|
||
substitute a different size media.
|
||
cAutoMediaNameOverride - The device is allowed to
|
||
substitute a different media name.
|
||
cUSMediaSizeOverride <20> The device is allowed to
|
||
substitute US media sizes (letter, etc.) for ISO media
|
||
sizes (A4, etc.).
|
||
cISOMediaSizeOverride <20> The device is allowed to
|
||
substitute ISO media sizes (A4, etc.) for US media
|
||
sizes (letter, etc.).
|
||
Additional information:
|
||
This object applies to all media requests,
|
||
including Manual Feed Requests.
|
||
This object describes the action that is performed
|
||
when the JOB-INPUT-AUTO-CONTINUE-TIMEOUT expires.
|
||
The action performed by the CONTINUE object being
|
||
set to eInitiateAction or the Go key being pressed on
|
||
the control panel may cause different actions.
|
||
See the CONTINUE object
|
||
description for information on the actions that occur
|
||
for those conditions."
|
||
::= { status-system 36 }
|
||
|
||
|
||
background-status-msg-line1-part1 OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..16))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The string displayed on the device's front panel in
|
||
place of the printer's built-in background status
|
||
string. An example built-in background status string is
|
||
'00 READY'.
|
||
Additional information:
|
||
The display size for the Color LaserJet8550 printer is 2 by 16.
|
||
The value of this object is displayed on the first
|
||
line and the value of
|
||
BACKGROUND-STATUS-MSG-LINE2-PART1 is displayed on
|
||
the second line of the display. Each object must
|
||
be set independently. If line 2 has been set, and
|
||
the next message to be displayed only requires
|
||
line 1, BACKGROUND-STATUS-MSG-LINE2-PART1 must be
|
||
set to the null string to clear it.
|
||
This object allows a message to be displayed when
|
||
it is the highest priority message waiting to be
|
||
displayed. Setting this object does not guarantee
|
||
the message will be displayed; and reading it
|
||
returns the value last written, not the currently
|
||
displayed message.
|
||
The priority assigned for displaying this message
|
||
is one lower than the PJL RDYMSG.
|
||
To clear the message, write a null string to both
|
||
this object and
|
||
BACKGROUND-STATUS-MSG-LINE2-PART1.
|
||
While the object prtConsoleLocalization controls
|
||
the localization and symbol set usage of printer
|
||
generated messages, this object's message is
|
||
displayed using the symbol set (note: The default
|
||
symbol set is Roman-8 for HP - EFI may vary)
|
||
specified with the string. The default symbol set
|
||
is Roman-8; additional legal symbol sets are
|
||
ISOLatin5, ISOLatin2, HalfWidthKatakana, and
|
||
ISOLatinCyrillic.
|
||
When either BACKGROUND-STATUS-MSG-LINE1-PART1 or
|
||
BACKGROUND-STATUS-MSG-LINE2-PART1 contains a
|
||
non-null value, both will be displayed."
|
||
::= { background-message1 1 }
|
||
|
||
|
||
background-status-msg-line2-part1 OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The string displayed on the device's front panel in
|
||
place of the printer's built-in background status
|
||
string. An example built-in background status string is
|
||
'00 READY'.
|
||
Additional information:
|
||
See BACKGROUND-STATUS-MSG-LINE1-PART1"
|
||
::= { background-message2 1 }
|
||
|
||
|
||
error-log-clear OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eClearErrorLog(1)
|
||
}
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Setting this object clears all the entries in the error
|
||
log sub-tree."
|
||
::= { status-system 38 }
|
||
|
||
|
||
job-output-auto-continue-timeout OBJECT-TYPE
|
||
SYNTAX INTEGER(-1..3600)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or sets the time that the printer will wait
|
||
after an output bin becomes full and the printer is
|
||
trying to deliver a sheet of media to that output bin.
|
||
When the timeout expires, the job is processed according
|
||
to the OUTBINn-OVERRIDE-MODE. A value of -1 indicates
|
||
that the printer will wait for a continue event. A non-
|
||
negative value is the number of seconds to wait.
|
||
Additional information:
|
||
Returns the time that the printer will wait
|
||
after an output bin becomes full and the printer is
|
||
trying to deliver a sheet of media to that output bin.
|
||
A value of -1 indicates that the printer will wait for
|
||
a continue event."
|
||
::= { status-system 40 }
|
||
|
||
|
||
collated-originals-support OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates that the printer can create multiple, collated
|
||
'originals' of a job and shows the level of support for
|
||
this capability.
|
||
cCollatedOriginals - The printer can create multiple
|
||
collated originals, or 'mopies'. This is the base
|
||
functionality required by the other collection items.
|
||
cProofAndHold - The printer saves a copy of the job
|
||
while printing the first mopy. Later, this held job can
|
||
be released and the rest of the mopies will print.
|
||
cSecurityPrint - The printer spools the job and holds
|
||
the job until the user releases the job by entering a
|
||
password at the printer's control panel.
|
||
cAutoHighlight - The printer prints the job a number
|
||
of times with a mail distribution list prepended to each
|
||
job. A different mailing address is highlighted on each
|
||
mopy.
|
||
cCollatedAtSpeed - The printer can create multiple
|
||
collated copies where all copies after the original are
|
||
printed at engine speed.
|
||
Additional information:
|
||
Indicates that the printer can create multiple, collated
|
||
originals of a job and shows the level of support for this
|
||
capability.
|
||
cCollatedOriginals - The printer can create multiple collated
|
||
originals, or mopies.
|
||
|
||
This is the base functionality required by the other
|
||
collection items. None of them are supported by Color LaserJet8550.
|
||
Without disk, this object will not exist. This will be set at
|
||
boot-up initialization. If the disk fails, in any way, then
|
||
the disk error functionality will handle the situation.
|
||
Note: Proof and print is not supported via PML."
|
||
::= { status-system 42 }
|
||
|
||
|
||
localization-languages-supported OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The list of languages supported by the device. The
|
||
languages are primarily, but not limited to, two
|
||
character codes from ISO 639, each separated by a comma
|
||
character.
|
||
Additional information:
|
||
This string will always be in the Roman-8 character set.
|
||
See prtLocalizationLanguage for details about each language
|
||
value."
|
||
::= { status-system 52 }
|
||
|
||
|
||
localization-countries-supported OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The list of countries supported by the device. The
|
||
countries are primarily, but not limited to, two
|
||
character codes from ISO 3166, each separated by a comma
|
||
character.
|
||
Additional information:
|
||
"
|
||
::= { status-system 53 }
|
||
|
||
|
||
model-number OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Identifies the device model number as listed in the HP
|
||
corporate price list (e.g. C2121A for DeskJet 500C).
|
||
The string is as specific as possible. Products should
|
||
note in POS if the model number on the CPL changes but
|
||
the device reports the previous model number. If the
|
||
model number changes based on the installed options, the
|
||
POS should indicate if only the base model number is
|
||
returned, or if the device senses the installed options
|
||
and returns the correct model number. If possible,
|
||
encode the model number in a symbol set (like Roman-8)
|
||
that matches the ASCII character set and limit the
|
||
characters used to ASCII characters.
|
||
Additional information:
|
||
The value of this object does not change based on
|
||
the installed options."
|
||
::= { id 1 }
|
||
|
||
|
||
model-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Identifies the device model name (e.g. ''DeskJet
|
||
1200C''). The string is as specific as possible.
|
||
Capitalization and spacing should match family naming
|
||
conventions. Products should note in POS if the model
|
||
name on the HP corporate price list changes but the
|
||
device reports the previous device name. If the model
|
||
name changes based on the installed options, the POS
|
||
should indicate if only the base model name is returned,
|
||
or if the device senses the installed options and
|
||
returns the correct model name. If possible, encode the
|
||
model name in a symbol set (like Roman-8) that matches
|
||
the ASCII character set and limit the characters used to
|
||
ASCII characters.
|
||
Additional information:
|
||
The value of this object does not change based on
|
||
the installed options.
|
||
Since the value of this object is frequently used in
|
||
displaying a list of printers, it is kept relatively short in
|
||
case systems have limited width for their display area."
|
||
::= { id 2 }
|
||
|
||
|
||
serial-number OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Identifies the serial number for the device. If the
|
||
SERIAL-NUMBER object is set by the user, then setting
|
||
the object does not need to be protected. If the
|
||
SERIAL-NUMBER object is set at the factory, then the
|
||
SERVICE-PASSWORD object must be set correctly before the
|
||
SERIAL-NUMBER object is writable. If this is a writable
|
||
object, the POS should indicate the maximum supported
|
||
string length. If possible, encode the serial number in
|
||
a symbol set (like Roman-8) that matches the ASCII
|
||
character set and limit the characters used to ASCII
|
||
characters.
|
||
Additional information:
|
||
This value is affected by NVRAM resets, it is set
|
||
to the default value of S4601LXXXXX, when a NVRAM
|
||
init is done.
|
||
This object is read-only so the SERVICE-PASSWORD
|
||
object is not used."
|
||
::= { id 3 }
|
||
|
||
|
||
device-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"User defined device name. The POS should indicate the
|
||
maximum supported string length. If the user entered
|
||
string is too long, the device will store as much as
|
||
possible and will return the <noError>.
|
||
|
||
Additional information:
|
||
The maximum supported string length is 32
|
||
characters. If the user entered string is too long,
|
||
the device will store the first 32 characters and will
|
||
return the <noError> status."
|
||
::= { id 10 }
|
||
|
||
|
||
device-location OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"User defined device location. The POS should indicate
|
||
the maximum supported string length. If the user
|
||
entered string is too long, the device will store as
|
||
much as possible and will return the <noError>.
|
||
|
||
Additional information:
|
||
The maximum supported string length is 16
|
||
characters. If the user entered string is too long,
|
||
the device will store the first 16 characters and will
|
||
return the <noError> status.
|
||
This object is saved in NVRAM."
|
||
::= { id 11 }
|
||
|
||
|
||
asset-number OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"User defined asset number. The POS should indicate the
|
||
maximum supported string length. If the user entered
|
||
string is too long, the device will store as much as
|
||
possible and will return the <noError>.
|
||
|
||
Additional information:
|
||
The maximum supported string length is 8
|
||
characters. If the user entered string is too long,
|
||
the device will store the first 8 characters and will
|
||
return the <noError> status.
|
||
This object is saved in NVRAM."
|
||
::= { id 12 }
|
||
|
||
|
||
simm1-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eEmpty(1),
|
||
eUnknown(2),
|
||
eUnSupported(3),
|
||
eReadOnlyMemory(4),
|
||
eVolatileRandomAccessMemory(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the type of option installed in
|
||
SIMM slot 1.
|
||
eEmpty means the device did not detect any option
|
||
installed in the interface slot.
|
||
eUnknown means the device doesn't recognize the
|
||
installed option.
|
||
eUnSupported means the device recognizes the installed
|
||
option, but does not support the option.
|
||
eReadOnlyMemory means the installed option contains
|
||
ROM Ics.
|
||
eVolatileRandomAccessMemory means the installed option
|
||
contains RAM ICs that loose data when the power is
|
||
turned off.
|
||
eNonVolatileRandomAccessMemory means that the
|
||
installed option contains RAM ICs that do not loose data
|
||
when the power is turned off.
|
||
eFlashMemory means that the installed option contains
|
||
a type of non-volatile RAM that needs to be erased
|
||
before it can be written.
|
||
eDiskDrive means the installed option contains a disk
|
||
drive. eRamRom means the installed option contains both
|
||
volatile random access memory and read only memory.
|
||
eInputPHD means the installed option is an input paper
|
||
handling device.
|
||
eOutputPHD means the installed option is an output
|
||
paper handling device.
|
||
eIOCard means the installed option is an I/O card.
|
||
Additional information:
|
||
Returns an indication of the type of option
|
||
installed in SIMM slot 1.
|
||
eEmpty means the device did not detect any option
|
||
installed in the interface slot.
|
||
eUnknown means the device doesn't recognize the
|
||
installed option.
|
||
eUnSupported means the device recognizes the installed
|
||
option, but does not support the option.
|
||
eReadOnlyMemory means the installed option contains
|
||
ROMICs.
|
||
eVolatileRandomAccessMemory means the installed
|
||
option contains RAM ICs that loose data when the power
|
||
is turned off."
|
||
::= { simm1 4 }
|
||
|
||
|
||
simm1-capacity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the capacity of the SIMM
|
||
installed in SIMM slot 1. The capacity is dependent on
|
||
the type of option, as indicated by the SIMM1-TYPE
|
||
object. This object has no meaning if the installed
|
||
option type is eUnknown or eReadOnlyMemory. This object
|
||
contains the size, in bytes, if the installed option
|
||
type is eVolatileRandomAccessMemory,
|
||
eNonVolatileRandomAccessMemory, eFlashMemory, or
|
||
eDiskDrive. If the type of the installed option is
|
||
eRamRom, this object contains the size, in bytes, of the
|
||
random access memory. If the type of the installed
|
||
option is eInputPHD, the capacity indicates the number
|
||
of input trays supported by the installed option. If
|
||
the type of the installed option is eOutputPHD, the
|
||
capacity indicates the number of output bins supported
|
||
by the installed option. If the type of the installed
|
||
option is eIOCard, the capacity indicates the number of
|
||
logical I/O ports supported by the I/O card.
|
||
Additional information:
|
||
Returns an indication of the capacity of the
|
||
installed option in bytes. This object is not
|
||
supported unless the SIMM1-TYPE type is
|
||
eVolatileRandomAccessMemory."
|
||
::= { simm1 5 }
|
||
|
||
|
||
simm2-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eEmpty(1),
|
||
eUnknown(2),
|
||
eUnSupported(3),
|
||
eReadOnlyMemory(4),
|
||
eVolatileRandomAccessMemory(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the type of option installed in
|
||
SIMM slot 2. See SIMM1-TYPE for a description."
|
||
::= { simm2 4 }
|
||
|
||
|
||
simm2-capacity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the capacity of the SIMM
|
||
installed in SIMM slot 2. See SIMM1-CAPACITY for a
|
||
description.
|
||
Additional information:
|
||
Returns an indication of the capacity of the
|
||
installed option in bytes. This object is not
|
||
supported unless the SIMM2-TYPE type is
|
||
eVolatileRandomAccessMemory."
|
||
::= { simm2 5 }
|
||
|
||
|
||
simm3-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eEmpty(1),
|
||
eUnknown(2),
|
||
eUnSupported(3),
|
||
eReadOnlyMemory(4),
|
||
eVolatileRandomAccessMemory(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the type of option installed in
|
||
SIMM slot 3. See SIMM1-TYPE for a description."
|
||
::= { simm3 4 }
|
||
|
||
|
||
simm3-capacity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the capacity of the SIMM
|
||
installed in SIMM slot 3. See SIMM1-CAPACITY for a
|
||
description.
|
||
Additional information:
|
||
Returns an indication of the capacity of the
|
||
installed option in bytes. This object is not
|
||
supported unless the SIMM3-TYPE type is
|
||
eVolatileRandomAccessMemory."
|
||
::= { simm3 5 }
|
||
|
||
|
||
simm4-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eEmpty(1),
|
||
eUnknown(2),
|
||
eUnSupported(3),
|
||
eReadOnlyMemory(4),
|
||
eVolatileRandomAccessMemory(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the type of option installed in
|
||
SIMM slot 4. See SIMM1-TYPE for a description."
|
||
::= { simm4 4 }
|
||
|
||
|
||
simm4-capacity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the capacity of the SIMM
|
||
installed in SIMM slot 4. See SIMM1-CAPACITY for a
|
||
description.
|
||
Additional information:
|
||
Returns an indication of the capacity of the
|
||
installed option in bytes. This object is not
|
||
supported unless the SIMM4-TYPE type is
|
||
eVolatileRandomAccessMemory."
|
||
::= { simm4 5 }
|
||
|
||
|
||
simm5-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eEmpty(1),
|
||
eUnknown(2),
|
||
eUnSupported(3),
|
||
eReadOnlyMemory(4),
|
||
eVolatileRandomAccessMemory(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the type of option installed in
|
||
SIMM slot 5. See SIMM1-TYPE for a description."
|
||
::= { simm5 4 }
|
||
|
||
|
||
simm5-capacity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the capacity of the SIMM
|
||
installed in SIMM slot 5. See SIMM1-CAPACITY for a
|
||
description.
|
||
Additional information:
|
||
Returns an indication of the capacity of the
|
||
installed option in bytes. This object is not
|
||
supported unless the SIMM5-TYPE type is
|
||
eVolatileRandomAccessMemory."
|
||
::= { simm5 5 }
|
||
|
||
|
||
simm6-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eEmpty(1),
|
||
eUnknown(2),
|
||
eUnSupported(3),
|
||
eReadOnlyMemory(4),
|
||
eVolatileRandomAccessMemory(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the type of option installed in
|
||
SIMM slot 6. See SIMM1-TYPE for a description."
|
||
::= { simm6 4 }
|
||
|
||
|
||
simm6-capacity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the capacity of the SIMM
|
||
installed in SIMM slot 6. See SIMM1-CAPACITY for a
|
||
description.
|
||
Additional information:
|
||
Returns an indication of the capacity of the
|
||
installed option in bytes. This object is not
|
||
supported unless the SIMM6-TYPE type is
|
||
eVolatileRandomAccessMemory."
|
||
::= { simm6 5 }
|
||
|
||
|
||
simm7-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eEmpty(1),
|
||
eUnknown(2),
|
||
eUnSupported(3),
|
||
eReadOnlyMemory(4),
|
||
eVolatileRandomAccessMemory(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the type of option installed in
|
||
SIMM slot 7. See SIMM1-TYPE for a description."
|
||
::= { simm7 4 }
|
||
|
||
|
||
simm7-capacity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the capacity of the SIMM
|
||
installed in SIMM slot 7. See SIMM1-CAPACITY for a
|
||
description.
|
||
Additional information:
|
||
Returns an indication of the capacity of the
|
||
installed option in bytes. This object is not
|
||
supported unless the SIMM7-TYPE type is
|
||
eVolatileRandomAccessMemory."
|
||
::= { simm7 5 }
|
||
|
||
|
||
simm8-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eEmpty(1),
|
||
eUnknown(2),
|
||
eUnSupported(3),
|
||
eReadOnlyMemory(4),
|
||
eVolatileRandomAccessMemory(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the type of option installed in
|
||
SIMM slot 8. See SIMM1-TYPE for a description."
|
||
::= { simm8 4 }
|
||
|
||
|
||
simm8-capacity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the capacity of the SIMM
|
||
installed in SIMM slot 8. See SIMM1-CAPACITY for a
|
||
description.
|
||
Additional information:
|
||
Returns an indication of the capacity of the
|
||
installed option in bytes. This object is not
|
||
supported unless the SIMM8-TYPE type is
|
||
eVolatileRandomAccessMemory."
|
||
::= { simm8 5 }
|
||
|
||
|
||
mio1-model-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns product information identifying the I/O card.
|
||
Example: XXXX"
|
||
::= { mio1 2 }
|
||
|
||
|
||
mio1-manufacturing-info OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns information describing the manufacture of the
|
||
I/O card installed in MIO/EIO slot 1. May include
|
||
serial number and firmware revision.
|
||
Additional information:
|
||
The format of the string returned is determined by
|
||
the manufacturer of the MIO card. There is no standard for
|
||
content of the string. If no card is installed, a null string
|
||
is returned."
|
||
::= { mio1 3 }
|
||
|
||
|
||
mio1-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eEmpty(1),
|
||
eUnknown(2),
|
||
eUnSupported(3),
|
||
eDiskDrive(8),
|
||
eIOCard(12)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the type of option installed in
|
||
MIO/EIO slot 1. See SIMM1-TYPE for an explanation of
|
||
the enumerations.
|
||
Additional information:
|
||
Returns an indication of the type of option installed
|
||
in MIO/EIO slot 1. See SIMM1-TYPE for explanation of eEmpty,
|
||
eUnknown, and eUnSupported.
|
||
eDiskDrive means the installed option contains a disk drive.
|
||
eIOCard means the installed option is an I/O card."
|
||
::= { mio1 4 }
|
||
|
||
|
||
mio2-model-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns product information identifying the I/O card.
|
||
Example: XXXX"
|
||
::= { mio2 2 }
|
||
|
||
|
||
mio2-manufacturing-info OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns information describing the manufacture of the
|
||
I/O card installed in MIO/EIO slot 2. May include
|
||
serial number and firmware revision.
|
||
Additional information:
|
||
The format of the string returned is determined by
|
||
the manufacturer of the MIO card. There is no standard for
|
||
content of the string. If no card is installed, a null string
|
||
is returned."
|
||
::= { mio2 3 }
|
||
|
||
|
||
mio2-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eEmpty(1),
|
||
eUnknown(2),
|
||
eUnSupported(3),
|
||
eDiskDrive(8),
|
||
eIOCard(12)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the type of option installed in
|
||
MIO/EIO slot 2. See SIMM1-TYPE for an explanation of
|
||
the enumerations.
|
||
Additional information:
|
||
Returns an indication of the type of option installed
|
||
in MIO/EIO slot 2. See MIO1-TYPE for an explanation of
|
||
the enumerations."
|
||
::= { mio2 4 }
|
||
|
||
|
||
phd1-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eEmpty(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the type of option installed as
|
||
PHD 1. See SIMM1-TYPE for an explanation of the
|
||
enumerations.
|
||
Additional information:
|
||
Color LaserJet8550 doesn't support envelope feeder but
|
||
software reserves PHD1 for envelope feeder.
|
||
All other PHD1 objects are removed."
|
||
::= { phd1 3 }
|
||
|
||
|
||
phd2-model OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns product information identifying PHD device 2.
|
||
Additional information:
|
||
If at least one (1) external paper handling
|
||
device is attached to the printer, then this object
|
||
will exist. Not applicable if the value of
|
||
PHD2-TYPE is eEmpty.
|
||
Returns product information about the first paper
|
||
handling device in the device chain."
|
||
::= { phd2 1 }
|
||
|
||
|
||
phd2-manufacturing-info OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns information describing the manufacture of PHD 2.
|
||
May include serial number and firmware revision.
|
||
Additional information:
|
||
If at least one (1) external paper handling
|
||
device is attached to the printer, then this object
|
||
will exist. Not applicable if the value of PHD2-TYPE
|
||
is eEmpty.
|
||
This object returns the name of the manufacturer of
|
||
the first paper handling device."
|
||
::= { phd2 2 }
|
||
|
||
|
||
phd2-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eEmpty(1),
|
||
eInputPHD(10),
|
||
eOutputPHD(11)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the type of option installed in
|
||
PHD interface 2. See SIMM1-TYPE for an explanation of
|
||
the enumerations.
|
||
Additional information:
|
||
External paper handling devices are connected to
|
||
the printer in a daisy-chained fashion. PHD2 refers
|
||
to the first device that is connected. Returns eEmpty
|
||
if no paper handling devices are installed.
|
||
If the HCI is attached, the value will be eInputPHD.
|
||
If the HCO is the first connected device, the value
|
||
will be eOutputPHD."
|
||
::= { phd2 3 }
|
||
|
||
|
||
phd2-capacity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the capacity of the installed
|
||
option. See SIMM1-CAPACITY for an explanation of the
|
||
meaning of the value of this object.
|
||
Additional information:
|
||
If at least one (1) external paper handling device (EPHD)
|
||
is attached to the printer, then this object will exist.
|
||
Not applicable if the value of PHD2-TYPE is eEmpty.
|
||
This object returns the number of input trays or output bins,
|
||
depending the device type (see PHD2-TYPE) for the first
|
||
EPHD in the device chain."
|
||
::= { phd2 4 }
|
||
|
||
|
||
phd3-model OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns product information identifying PHD device 3.
|
||
Additional information:
|
||
If at least two (2) external paper handling devices
|
||
are attached to the printer, then this object will
|
||
exist. Not applicable if the value of PHD3-TYPE is
|
||
eEmpty."
|
||
::= { phd3 1 }
|
||
|
||
|
||
phd3-manufacturing-info OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns information describing the manufacture of PHD 3.
|
||
May include serial number and firmware revision.
|
||
Additional information:
|
||
If at least two (2) external paper handling
|
||
devices are attached to the printer, then this object
|
||
will exist. Not applicable if the value of PHD3-TYPE
|
||
is eEmpty. This object returns the name of the
|
||
manufacturer of the second paper handling device."
|
||
::= { phd3 2 }
|
||
|
||
|
||
phd3-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eEmpty(1),
|
||
eInputPHD(10),
|
||
eOutputPHD(11)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the type of option installed in
|
||
PHD interface 3. See SIMM1-TYPE for an explanation of
|
||
the enumerations.
|
||
Additional information:
|
||
External paper handling devices are connected to
|
||
the printer in a daisy-chained fashion. PHD3 refers to
|
||
the second device that is connected. Returns eEmpty if
|
||
no paper handling devices are installed.
|
||
If the HCI is attached, the value will be eInputPHD.
|
||
If the HCO is the second connected device, the value
|
||
will be eOutputPHD."
|
||
::= { phd3 3 }
|
||
|
||
|
||
phd3-capacity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the capacity of the installed
|
||
option. See SIMM1-CAPACITY for an explanation of the
|
||
meaning of the value of this object.
|
||
Additional information:
|
||
If at least two (2) external paper handling
|
||
devices (EPHD) are attached to the printer, then
|
||
this object will exist. Not applicable if the value
|
||
of PHD3-TYPE is eEmpty.
|
||
This object returns the number of input trays or
|
||
output bins, depending the device type (see
|
||
PHD3-TYPE) for the second EPHD in the device chain."
|
||
::= { phd3 4 }
|
||
|
||
|
||
phd4-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eEmpty(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the type of option installed in
|
||
PHD interface 4. See SIMM1-TYPE for an explanation of
|
||
the enumerations.
|
||
Additional information:
|
||
External paper handling devices are connected to
|
||
the printer in a daisy-chained fashion. PHD4 refers to
|
||
the third device that is connected.
|
||
Returns the type of the third party device in this
|
||
chain, otherwise, eEmpty if only tow paper handling
|
||
devices are installed.
|
||
At introduction, there is no planned configuration
|
||
that would cause the value of this object to be
|
||
anything other than eEmpty."
|
||
::= { phd4 3 }
|
||
|
||
|
||
phd5-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eEmpty(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the type of option installed in
|
||
PHD interface 5. See SIMM1-TYPE for an explanation of
|
||
the enumerations.
|
||
Additional information:
|
||
External paper handling devices are connected to
|
||
the printer in a daisy-chained fashion. PHD5 refers to
|
||
the forth device that is connected. Returns eEmpty if
|
||
only four paper handling devices are installed.
|
||
At introduction, there is no planned configuration
|
||
that would cause the value of this object to be
|
||
anything other than eEmpty."
|
||
::= { phd5 3 }
|
||
|
||
|
||
phd6-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eEmpty(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns an indication of the type of option installed in
|
||
PHD interface 6. See SIMM1-TYPE for an explanation of
|
||
the enumerations.
|
||
Additional information:
|
||
External paper handling devices are connected to
|
||
the printer in a daisy-chained fashion. PHD6 refers to
|
||
the fifth device that is connected. Returns eEmpty if
|
||
only four paper handling devices are installed.
|
||
At introduction, there is no planned configuration
|
||
that would cause the value of this object to be
|
||
anything other than eEmpty."
|
||
::= { phd6 3 }
|
||
|
||
|
||
self-test OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eNotInASelfTest(1),
|
||
eNonDestructiveSelfTest(4)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Writing this object allows a device self test to be
|
||
started. Reading this object provides an indication
|
||
what self-test is currently executing, if any. Actual
|
||
self-test operation is device specific. A self test may
|
||
not be allowed at any arbitrary time. If the device
|
||
supports the requested self test, but can not start the
|
||
execution of the self test when requested, the device
|
||
will respond with <genErr>. If
|
||
a non-destructive self test is being started, the device
|
||
will generate a response before the self test is
|
||
completed.
|
||
RECOMMENDATION: If the device is ready (i.e. the NOT-
|
||
READY-PRINTER object does not contain any items, except
|
||
maybe being off-line) and is idle (i.e. the NOT-IDLE
|
||
object does not contain any items), this request should
|
||
always succeed. This provides a mechanism for driver
|
||
writers to always determine if the action will succeed
|
||
or not.
|
||
Additional information:
|
||
The eNonDestructiveSelfTest performs limited
|
||
testing on the printer and its attached paper handling
|
||
devices. After the self-test is complete a
|
||
configuration page is printed. The recommended way to
|
||
cause a configuration page to be printed is to use the
|
||
PRINT-INTERNAL-PAGE object.
|
||
A continuous self test cannot be started
|
||
or terminated using this OID.
|
||
When the printer is idle, setting this object to
|
||
eNonDestructiveSelfTest results in a status of <noError>
|
||
and a value of eNonDestructiveSelfTest being returned.
|
||
If the printer is not idle (whether printing an
|
||
external job, printing an internal page or running
|
||
self test), a status of
|
||
<genErr> status will be
|
||
returned with a value of eNotInASelfTest.
|
||
When the printer is idle, setting this object to
|
||
eNonDestructiveSelfTest causes some internal testing,
|
||
the page to be formatted and put in the printer's
|
||
print queue. Before the page is in the print queue, a
|
||
get on this object will return eNonDestructiveSelfTest
|
||
Attempting to set this object before the page has
|
||
completed being formatted and printed will cause
|
||
<genErr> status to be
|
||
returned with a value of eNotInASelfTest.
|
||
After the page is in the queue, a get on this object
|
||
will return a value of eNotInASelfTest.
|
||
Setting this object to eNonDestructiveSelfTest
|
||
before the first page has completed results in
|
||
a status of <genErr> status
|
||
with a value of eNotInASelfTest.
|
||
Likewise, if the PRINT-INTERNAL-PAGE object is set to
|
||
a valid value and that page has not printed
|
||
when this object is set to eNonDestructiveSelfTest, a
|
||
status of <genErr> status
|
||
with a value of eNotInASelfTest will be
|
||
returned until the internal page has printed."
|
||
::= { test 1 }
|
||
|
||
|
||
print-internal-page OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eNotPrintingAnInternalPage(1),
|
||
ePrintingAnUnknownInternalPage(2),
|
||
eDeviceDemoPage1ConfigurationPage(3),
|
||
eDeviceDemoPage2(4),
|
||
eDeviceDemoPage5ErrorLog(7),
|
||
eDeviceDemoPage6FileSystemDirectoryListing(8),
|
||
eDeviceDemoPage7MenuMap(9),
|
||
ePCLFontList1(350),
|
||
ePostScriptFontList1(450),
|
||
eMarkingAgentTestPattern(1000)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Writing this object to a value other than
|
||
eNotPrintingAnInternalPage causes the device to attempt
|
||
to print an internally generated page. Reading this
|
||
object provides an indication what internally generated
|
||
page is currently being printed, if any. The actual
|
||
page is device specific. Some devices may support
|
||
continuously printing an internally generated page.
|
||
Setting this object to eNotPrintingAnInternalPage
|
||
terminates continuously printing internally generated
|
||
pages. An internally generated page may not be allowed
|
||
to be printed at any arbitrary time; under what
|
||
conditions it will succeed or fail is device specific.
|
||
If the device supports the requested page, but can not
|
||
start printing the page when requested, the device will
|
||
respond with <genErr>.
|
||
RECOMMENDATION: If the device is ready (i.e. the NOT-
|
||
READY-PRINTER object does not contain any items, except
|
||
maybe being off-line) and is idle (i.e. the NOT-IDLE
|
||
object does not contain any items), this request should
|
||
always succeed. This provides a mechanism for driver
|
||
writers to always determine if the action will succeed
|
||
or not.
|
||
Additional information:
|
||
PCL and PS config. pages for Color LaserJet8550 are the same.
|
||
Only 1 page for info on both PCL and PS.
|
||
PCL and PS font lists are different.
|
||
|
||
eDeviceDemoPage2 is the printer demo page.
|
||
ePCLFontList1 is the PCL typeface list.
|
||
eDeviceDemoPage5ErrorLog is the printer's error log.
|
||
Color LaserJet8550 does not support continuously printing a demo
|
||
page.
|
||
|
||
The value eDeviceDemoPage6FileSystemDirectoryListing
|
||
can only be set when the disk option is installed.
|
||
|
||
When this object is set to a valid value and the
|
||
printer is idle, the status returned is <noError> and the
|
||
value returned is ePrintingAnUnknownInternalPage. If
|
||
the printer is not idle (whether printing an external
|
||
job, printing an internal page or executing a self
|
||
test), a status of <genErr>
|
||
status will be returned with a value of
|
||
eNotPrintingAnInternalPage.
|
||
|
||
Setting this object to a valid value causes the
|
||
desired page to be formatted and put in the printer's
|
||
print queue. While the page is being formatted a get
|
||
on this object will return the value
|
||
ePrintingAnUnknownInternalPage, if
|
||
the time to format the page is long enough (it is
|
||
currently estimated that the time to format some pages
|
||
is as short as one millisecond).
|
||
Attempting to set this object before the page has
|
||
completed being formatted and printed will cause
|
||
<genErr> status to be
|
||
returned with a value of
|
||
eNotPrintingAnInternalPage.
|
||
|
||
After the page is in the queue, a get on this object
|
||
will return a value of eNotPrintingAnInternalPage.
|
||
Setting this object to cause another page to be
|
||
printed before the first page has completed results in
|
||
a status of <genErr> status
|
||
with a value of eNotPrintingAnInternalPage.
|
||
|
||
Likewise, if the SELF-TEST object is set to
|
||
eNonDestructiveSelfTest and that page has not printed
|
||
when this object is set to print a page, a status of
|
||
<genErr> status
|
||
with a value of eNotPrintingAnInternalPage will be
|
||
returned until the self test page has printed."
|
||
::= { test 2 }
|
||
|
||
|
||
cancel-job OBJECT-TYPE
|
||
SYNTAX INTEGER(0..32767)
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Cancels the print job whose ID matches the value written
|
||
to the CANCEL-JOB object. The host first learns the job
|
||
ID using the CURRENT-JOB-PARSING-ID command. If the
|
||
printer has completely processed the job, the printer
|
||
responds with <badValue>. If the
|
||
value of the CURRENT-JOB-PARSING-ID is smaller than the
|
||
value written to the CANCEL-JOB object, then the printer
|
||
responds with <badValue>. When
|
||
read, returns the value of the last job ID what was
|
||
canceled, or -1 to indicate no job has been canceled.
|
||
Additional information:
|
||
If the value written matches the ID of a job that is
|
||
currently being canceled (for any reason), the printer
|
||
responds with <noError>.
|
||
Color LaserJet8550 uses job ID's in the range of 0..32767.
|
||
Because the ID number can wrap to zero, CURRENT-JOB-PARSING-ID
|
||
may be smaller than the value written to this object; when this
|
||
occurs, no error will result as long as the ID is for a
|
||
currently processing job."
|
||
::= { settings-job 2 }
|
||
|
||
|
||
job-info-change-id OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the current value of an object in the job-info
|
||
sub-tree whose value has changed. Define the object
|
||
identifier for the object whose value has changed as
|
||
job-info.required-field.optional-field.job-id. job-info
|
||
represents the OID prefix of all objects in the job-info
|
||
sub-tree. Required-field represents the OID field value
|
||
that follows the job-info prefix. Since some objects in
|
||
the job-info sub-tree have two OID fields between the
|
||
job-info prefix and the job-id, the optional-field
|
||
represents the OID field between the required-field and
|
||
the job-id field, if present. Using this definition,
|
||
the format for the JOB-INFO-CHANGE-ID binary value can
|
||
be described as follows:
|
||
Bytes 0-3 : required-field
|
||
Bytes 4-7 : optional-field, or all zeros if there
|
||
is no optional field
|
||
Bytes 8-11: Job ID.
|
||
Bytes 12-n : The value of the object job-info.
|
||
required-field.optional-field.job-id.
|
||
All multi-byte values stored in Motorola (big-endian)
|
||
format, where the most significant byte occurs first.
|
||
Additional information:
|
||
Color LaserJet8550 will use this object to report changes of the
|
||
job-info-pages-printed and job-info-state objects.
|
||
The required-field (bytes - through 3) will designate
|
||
whether the change to be reported involuves the pages
|
||
printed (13) or job state (15). The optionl-field
|
||
(bytes4 through 7) will always be zeroes. The value-
|
||
field (bytes 12 through 15) will contain the new value
|
||
for pages printed or job state cast to a
|
||
32-byt integer."
|
||
::= { settings-job 3 }
|
||
|
||
|
||
hold-job-timeout OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The time, in minutes, that the printer will wait before
|
||
automatically deleting a held job. This allows the
|
||
printer to automatically clean up jobs that have been
|
||
forgotten (held but never released).
|
||
Additional information:
|
||
This only applies to temporary held jobs, i.e., HOLD=ON or
|
||
PROOF. This is a global timer that only affects the jobs
|
||
that are sent after it is set.
|
||
A value of 0 means never delete the jobs.
|
||
Setting it to an unsupported value causes
|
||
the printer to substitute a value (listed
|
||
below) and to return <noError>
|
||
status.
|
||
Color LaserJet8550 supports values of 0, 60, 240, 1440, and 10080
|
||
The values are as follows:
|
||
<=0 snap to 0 (disabled)
|
||
>=1 and <=150 snap to 60 (60 minutes)
|
||
>=151 and <=840 snap to 240 (4 hours)
|
||
>=841 and <=2880 snap to 1440 (1 day)
|
||
>=2881 snap to 10080 (1 week)"
|
||
::= { settings-job 10 }
|
||
|
||
|
||
current-job-parsing-id OBJECT-TYPE
|
||
SYNTAX INTEGER(-1..32767)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains the printer assigned job identification for the
|
||
job currently being processed by the processing PDL sub-
|
||
system. The job ID is a monotonically increasing
|
||
number. The job ID may be reset to zero at power-up and
|
||
may roll over to zero after reaching some maximum
|
||
value.
|
||
Additional information:
|
||
A value of -1 is returned when the printer is
|
||
not parsing a job.
|
||
When data for a new job is detected, this object is
|
||
updated (the job may or may not turn out to be a Null
|
||
Job); however, the trap does not occur until the
|
||
printer determines that it is not a Null Job
|
||
(a trapped value will differ from the previous value
|
||
name or job attribute, causes no pages to be printed,
|
||
by one or more).
|
||
Some JOB-INFO- objects are created when the first data
|
||
bytes are received. If the printer determines that the
|
||
job is a Null Job, the JOB-INFO- objects related to
|
||
the Null Job are deleted. Color LaserJet8550 retains the
|
||
JOB-INFO- objects for the 24 most recent jobs that are
|
||
not Null Jobs."
|
||
::= { job-being-parsed 1 }
|
||
|
||
|
||
job-info-name1 OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains the first part of this print job's name. The
|
||
last OID field for this dynamic object contains the job
|
||
ID.
|
||
Additional information:
|
||
The job name is the string specified by the
|
||
NAME= parameter of the @PJL JOB command which
|
||
allows a maximum of 80 characters. The first 40
|
||
characters are in this object and the second 40 are in
|
||
JOB-INFO-NAME2. The symbol set is Roman-8.
|
||
When jobs are nested, the value assigned to this object
|
||
is the name provided by the most recent
|
||
@PJL JOB NAME= command. If no name is provided,
|
||
a null string is returned. "
|
||
::= { job-info 1 }
|
||
|
||
|
||
job-info-name2 OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains the second part of this print job's name. The
|
||
last OID field for this dynamic object contains the job
|
||
ID.
|
||
Additional information:
|
||
See JOB-INFO-NAME1."
|
||
::= { job-info 2 }
|
||
|
||
|
||
job-info-stage OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates what printer sub-systems are currently
|
||
processing this print job. The last OID field for this
|
||
dynamic object contains the job ID.
|
||
cSourceSubsystem - some of the job is in the printer
|
||
I/O subsystem.
|
||
cProcessingSubsystem - some of the job is in the
|
||
printer imaging processing subsystem.
|
||
cDestinationSubsystem - some of the job is being
|
||
printed.
|
||
Additional information:
|
||
For Color LaserJet8550 cSourceSubsystem and cProcessingSubsystem
|
||
will always be set and cleared together.
|
||
A non-printing job will never set cDestinationSubsystem.
|
||
When a page is ready to be printed (the intermediate has been
|
||
built), cDestinationSubsystem will be set even if
|
||
a page of a previous job is currently being printed.
|
||
cDestinationSubsystem remains set until the last page of the
|
||
job has reached an output bin.
|
||
If a page requires extensive processing and allows all the
|
||
previous pages of a job to complete printing
|
||
cDestinationSubsystem will remain set until the last page of
|
||
the job is closed."
|
||
::= { job-info 10 }
|
||
|
||
|
||
job-info-io-source OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates which I/O source, the print job was received
|
||
over. The value maps to port numbering scheme supported
|
||
in the DEVICE/SOURCE-SUBSYSTEM/IO/PORTS sub-tree."
|
||
::= { job-info 11 }
|
||
|
||
|
||
job-info-pages-processed OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates the number of pages processed by the
|
||
processing subsystem. If neither the cSourceSubsystem
|
||
or the cProcessingSubsystem items are in the associated
|
||
JOB-INFO-STAGE object, then this object contains the
|
||
total number of pages processed for this job. The last
|
||
OID field for this dynamic object contains the job ID.
|
||
Additional information:
|
||
This object is incremented by one when a page is
|
||
processed, regardless of the number of pages that are printed
|
||
as a result of the single page processed. In other words,
|
||
it does not matter how many identical copies of a page are
|
||
printed, or no pages may be printed if operating in silent
|
||
run mode, this count is incremented only once.
|
||
A page is considered processed when all of the input data has
|
||
been processed for a page (the intermediate has been produced);
|
||
the image of the page is not necessarily completely formed."
|
||
::= { job-info 12 }
|
||
|
||
|
||
job-info-pages-printed OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates the number of pages printed by the destination
|
||
subsystem. If non of the cSourceSubsystem,
|
||
cProcessingSubsystem or cDestinationSubsystem items are
|
||
in the associated JOB-INFO-STAGE object, then this
|
||
object contains the total number of pages printed for
|
||
this job. This value may increase by two each time for
|
||
duplex jobs. The last OID field for this dynamic object
|
||
contains the job ID.
|
||
Additional information:
|
||
Indicates the number of pages printed (i.e., the page
|
||
has reached the output tray) by the destination subsystem.
|
||
If multiple copies of a page are printed, each copy
|
||
is counted individually. Duplexed pages count as 2 pages."
|
||
::= { job-info 13 }
|
||
|
||
|
||
job-info-size OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates the number of bytes of data processed by the
|
||
processing subsystem. If neither of the
|
||
cSourceSubsystem or cProcessingSubsystem items are in
|
||
the associated JOB-INFO-STAGE object, then this object
|
||
contains the size of this job, in bytes. The last OID
|
||
field for this dynamic object contains the job ID.
|
||
Additional information:
|
||
This count may be incremented by values other than one
|
||
as blocks of data are processed; blocks of data (which may be
|
||
as large as 2K bytes) will be processed in a varying amount of
|
||
time.
|
||
When a job completes, this count may not be the same as the
|
||
total number of bytes sent to the printer since some data
|
||
before or after the job may be considered to be outside the
|
||
job. Also, for ill-formed PostScript jobs (ones that do not
|
||
use the ENTER LANGUAGE command) will be reported as having
|
||
approximately 256 extra bytes due to the way the language
|
||
switching is accomplished."
|
||
::= { job-info 14 }
|
||
|
||
|
||
job-info-state OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eAborted(3),
|
||
eWaitingForResources(4),
|
||
ePrinted(5),
|
||
eRetained(6),
|
||
eTerminating(7),
|
||
ePaused(9),
|
||
eCancelled(10),
|
||
eProcessing(11)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates the state of the job. The last OID field for
|
||
this dynamic object contains the job ID.
|
||
eAborted - the print job was aborted.
|
||
eWaitingForResources - the print job requires
|
||
resources that are not currently available. Example
|
||
resources that can cause the job to wait include the
|
||
print engine or PDL processor being unavailable. The
|
||
print engine could be unavailable due to paper out,
|
||
paper jam, staple out, stapler jam, marking agent low,
|
||
output bin full, etc. The PDL processor could be
|
||
unavailable due to an off-line condition. Each printer
|
||
specific object specification should state which
|
||
conditions cause a job to be waiting for resources and
|
||
also state which objects can be retrieved by an
|
||
application to determine the exact cause of a resource
|
||
being unavailable.
|
||
ePrinted - the job has printed. The related JOB-INFO-
|
||
OUTCOME object indicates if any problems were
|
||
encountered while the job was processed.
|
||
eRetained - the job can be reprinted.
|
||
eTerminating - the job was aborted or cancelled and is
|
||
currently is terminating.
|
||
eInterrupted - the job has been interrupted. The job
|
||
can be continued.
|
||
ePaused - the job has been paused. The job can be
|
||
continuted.
|
||
eCancelled - the job has been cancelled.
|
||
eProcessing - the job is currently being printed
|
||
normally.
|
||
Additional information:
|
||
Indicates the state of the job. The last OID field for
|
||
this dynamic object contains the job ID
|
||
eAborted - the print job was aborted.
|
||
eWaitingForResources - the print job requires resources
|
||
that are not currently available. Example
|
||
resources that can cause the job to wait
|
||
include the print engine or PDL processor
|
||
being unavailable due to paper out, paper jam,
|
||
marking agent low, output bin full, etc.
|
||
The PDL processor could be unavailable due to
|
||
an off-line condition.
|
||
ePrinted - the job has printed. The related
|
||
JOB-INFO-OUTCOME object indicates if any
|
||
problms were encountered while the job was
|
||
precessed.
|
||
eRetained - the job can be reprinted.
|
||
eTerminating - the job was aborted or cancelled and is
|
||
currently is terminating.
|
||
ePaused - the job has been paused. The job can be
|
||
continued.
|
||
eCancelled - the job has been cancelled.
|
||
eProcessing - the job is currently being printed
|
||
normally."
|
||
::= { job-info 15 }
|
||
|
||
|
||
job-info-outcome OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eOk(3),
|
||
eWarningsEncountered(4),
|
||
eErrorsEncountered(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates if any warning or error conditions were
|
||
encountered while processing the assoicated job. The
|
||
last OID field for this dynamic object contains the job
|
||
ID."
|
||
::= { job-info 19 }
|
||
|
||
|
||
job-info-outbins-used OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates which output bins this job has delivered
|
||
printed pages to. The last OID field for this dynamic
|
||
object contains the job ID.
|
||
Additional information:
|
||
The bins designated by this collection include the
|
||
printer's own output bins as well as the 'logical output bins'
|
||
associated with any attached external paper handling devices.
|
||
(The mapping of the physical output bins of an external paper
|
||
handling device to its 'logical output bins' depends on the
|
||
usage mode of the device. For instance, in 'mailbox mode',
|
||
there is one-to-one correspondence of 'logical output bins' to
|
||
physical bins, whereas in 'stacker mode', one 'logical output
|
||
bin' may map to several physical bins.)
|
||
If a bin is used as an overflow bin, then its bit will be set
|
||
as well.
|
||
cOutbin1 is the top/face-down bin.
|
||
cOutbin2 is the left/face-up bin.
|
||
"
|
||
::= { job-info 20 }
|
||
|
||
|
||
job-info-physical-outbins-used OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates which physical output bins this job has
|
||
delivered printed pages to. The last OID field for this
|
||
dynamic object contains the job ID.
|
||
Additional information:
|
||
Bits in this object are set only if printed pages were
|
||
delivered to an external paper handling device. This object is
|
||
supported regardless of whether or not an external device is
|
||
installed. The bits set map to the device's bins in a device
|
||
specific manner. If the device does not report to the formatter
|
||
which bins are used, then no bits will be set.
|
||
For the HCO, the bins map to the bits as follows:
|
||
cOutbin1--Face-up bin
|
||
cOutbin2--Bin1
|
||
cOutbin3--Bin2
|
||
cOutbin4--Bin3
|
||
cOutbin5--Bin4
|
||
cOutbin6--Bin5
|
||
cOutbin7--Bin6
|
||
cOutbin8--Bin7
|
||
cOutbin9--Bin8
|
||
cOutbin10--Bin9 "
|
||
::= { job-info 22 }
|
||
|
||
|
||
job-info-attr-1 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. Attribute objects are saved
|
||
sequentially, starting with 1, after the start of a job.
|
||
If more attributes are set than there are objects to
|
||
store them, the excess JOBATTR values are ignored. If
|
||
the corresponding SET JOBATTR= command has not been
|
||
received when a get is done for this object, a status of
|
||
<noSuchName> will be returned."
|
||
::= { job-info-attribute 1 }
|
||
|
||
|
||
job-info-attr-2 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 2 }
|
||
|
||
|
||
job-info-attr-3 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 3 }
|
||
|
||
|
||
job-info-attr-4 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 4 }
|
||
|
||
|
||
job-info-attr-5 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 5 }
|
||
|
||
|
||
job-info-attr-6 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 6 }
|
||
|
||
|
||
job-info-attr-7 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 7 }
|
||
|
||
|
||
job-info-attr-8 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 8 }
|
||
|
||
|
||
job-info-attr-9 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 9 }
|
||
|
||
|
||
job-info-attr-10 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 10 }
|
||
|
||
|
||
job-info-attr-11 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 11 }
|
||
|
||
|
||
job-info-attr-12 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 12 }
|
||
|
||
|
||
job-info-attr-13 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 13 }
|
||
|
||
|
||
job-info-attr-14 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 14 }
|
||
|
||
|
||
job-info-attr-15 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 15 }
|
||
|
||
|
||
job-info-attr-16 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 16 }
|
||
|
||
|
||
job-info-attr-17 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 17 }
|
||
|
||
|
||
job-info-attr-18 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 18 }
|
||
|
||
|
||
job-info-attr-19 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 19 }
|
||
|
||
|
||
job-info-attr-20 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 20 }
|
||
|
||
|
||
job-info-attr-21 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 21 }
|
||
|
||
|
||
job-info-attr-22 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 22 }
|
||
|
||
|
||
job-info-attr-23 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 23 }
|
||
|
||
|
||
job-info-attr-24 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 24 }
|
||
|
||
|
||
job-info-attr-25 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 25 }
|
||
|
||
|
||
job-info-attr-26 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 26 }
|
||
|
||
|
||
job-info-attr-27 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 27 }
|
||
|
||
|
||
job-info-attr-28 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 28 }
|
||
|
||
|
||
job-info-attr-29 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 29 }
|
||
|
||
|
||
job-info-attr-30 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 30 }
|
||
|
||
|
||
job-info-attr-31 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 31 }
|
||
|
||
|
||
job-info-attr-32 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the value that was set in PJL via the SET
|
||
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 32 }
|
||
|
||
|
||
job-info-requested-originals OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The number of requested collated copies. The value was
|
||
supplied with the job via PJL QTY variable, the
|
||
PostScript Collate and NumCopies entries in the page
|
||
device dictionary, or via some other mechansim."
|
||
::= { job-info 24 }
|
||
|
||
|
||
job-info-page-count-current-original OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The page number being printed within the current copy of
|
||
a collated multi-copy job. This value changes when the
|
||
job-info-pages-printed changes. The job-info-pages-
|
||
printed indicates the total number of pages printed in
|
||
the job, while this object indicates the number of pages
|
||
printed for this copy of a collated multi-copy job."
|
||
::= { job-info 25 }
|
||
|
||
|
||
job-info-pages-in-original OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Number of pages in a single copy of a collated multi-
|
||
copy job."
|
||
::= { job-info 26 }
|
||
|
||
|
||
job-info-printed-originals OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Number of collated copies completely printed and
|
||
delivered to the output bin at time of query.
|
||
Additional information:
|
||
Number of collated copies completly printed at time of query."
|
||
::= { job-info 27 }
|
||
|
||
|
||
held-job-user-name OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..40))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"User name that is obtained by the driver through some
|
||
internal method or from user input.
|
||
Additional information:
|
||
The following is a general description for all the JOB-MANAGEMENT
|
||
objects described below. These object describe the attributes of the
|
||
dynamic list containing all the stored jobs on the disk available for
|
||
printing or deleting via the job-management feature. The jobs on this
|
||
list are not deleted from the disk unless explicitly specified by the
|
||
user. A print job may be specified for retention by PJL commands in the
|
||
data stream.
|
||
|
||
Following is a list of the PJL commands (i.e. these comments describe
|
||
the PJL implementation and in some cases do not reflect the PML
|
||
implementation.):
|
||
|
||
@PJL SET HOLD=OFF|ON|PROOF|STORE|PRINT
|
||
|
||
GENERAL DESCRIPTION:
|
||
|
||
This variable specifies the retention classification of the job. The
|
||
values indicate whether the job is printed immediately and/or stored.
|
||
|
||
OFF: The job is printed but not retained on disk after printing. This
|
||
is the default value.
|
||
|
||
ON: This setting may be thought of as free proof-and-hold. The
|
||
requested number of copies will be printed and the job will be
|
||
temporarily stored on disk. The job will then be available for printing
|
||
additional copies through the control panel and through PML. There will
|
||
be a limit to the number of these temporary jobs that may be stored, and
|
||
when the limit is exceeded the oldest job will be removed from the disk.
|
||
|
||
PROOF: One copy of the job is printed and remaining copies are stored
|
||
on disk. The job is then available to select for printing via the
|
||
control panel menus or PML. The job will be deleted from the disk when
|
||
the disk space is needed for another proof and hold job but only after
|
||
the additional copies have been printed. It will also be deleted when
|
||
the user sends down another proof and hold job with the same job name,
|
||
or the user explicitly deletes the job.
|
||
|
||
STORE: The job is not printed immediately but is retained on disk. The
|
||
job is available to select for printing via the control panel
|
||
|
||
DEFAULT VALUE: OFF
|
||
|
||
The value will be stored in RAM only, not in NVRAM.
|
||
The legal PJL commands are SET and INQUIRE. DEFAULT is not allowed.
|
||
The variable will appear in the PJL INFO VARIABLES list.
|
||
|
||
@PJL SET USERNAME=<80 bytes>
|
||
|
||
GENERAL DESCRIPTION:
|
||
|
||
Eighty-character user name that is obtained by the driver through some
|
||
internal method or from user input. If the job stream does not contain
|
||
a USERNAME the default value will be NO USER NAME. The driver is
|
||
responsible for determining the size of the printers control panel and
|
||
sending a string of appropriate length.
|
||
|
||
DEFAULT VALUE: NO USER NAME
|
||
|
||
The value will be stored in RAM only, not in NVRAM.
|
||
The legal PJL commands are SET and, INQUIRE. DEFAULT is not allowed.
|
||
The variable will appear in the PJL INFO VARIABLES list.
|
||
|
||
@PJL SET JOBNAME=<80 bytes>
|
||
|
||
GENERAL DESCRIPTION:
|
||
|
||
Eighty-character job name that may be generated by the driver or
|
||
obtained from user input. This value may be used in conjunction with
|
||
the USERNAME to select a job from the front panel. If the job stream
|
||
does not contain a JOBNAME, the printer will assume no job name; each
|
||
subsequent job that is sent down by the same user would replace the
|
||
users last job on disk. The driver is responsible for determining the
|
||
size of the printers control panel and sending a string of appropriate
|
||
length.
|
||
|
||
NOTE: The limit of 80 bytes is a PJL limit. The limit for PML will
|
||
be 40 bytes.
|
||
|
||
DEFAULT VALUE: NULL STRING
|
||
|
||
The value will be stored in RAM only, not in NVRAM.
|
||
The legal PJL commands are SET and INQUIRE. DEFAULT is not allowed.
|
||
The variable will appear in the PJL INFO VARIABLES list.
|
||
|
||
@PJL SET HOLDTYPE=PUBLIC|PRIVATE
|
||
|
||
GENERAL DESCRIPTION:
|
||
|
||
This variable specifies the privacy level of the job.
|
||
|
||
PUBLIC: The job does not require a PIN in order to be released for
|
||
printing. This is the default value.
|
||
|
||
PRIVATE: The job requires a PIN in order to be released for printing.
|
||
The PIN is specified by the HOLDKEY variable. If the
|
||
|
||
HOLDTYPE is set to PRIVATE, a HOLDKEY value must be specified. If no
|
||
HOLDKEY is specified, the job will be considered PUBLIC.
|
||
|
||
DEFAULT VALUE: PUBLIC
|
||
|
||
The value will be stored in RAM only, not in NVRAM.
|
||
The legal PJL commands are SET and INQUIRE. DEFAULT is not allowed.
|
||
The variable will appear in the PJL INFO VARIABLES list.
|
||
|
||
@PJL SET HOLDKEY=4 digits, 0000...9999
|
||
|
||
GENERAL DESCRIPTION:
|
||
|
||
A 4-digit string, each digit 0-9, that is specified in the job stream
|
||
and then required to be entered in order to release the job for
|
||
printing. If a HOLDTYPE is PRIVATE, a HOLDKEY value must be specified.
|
||
If no HOLDKEY value is specified, a job will be considered PUBLIC.
|
||
|
||
DEFAULT VALUE: NULL STRING
|
||
|
||
The value will be stored in RAM only, not in NVRAM.
|
||
The legal PJL commands are SET and INQUIRE. DEFAULT is not allowed.
|
||
The variable will appear in the PJL INFO VARIABLES list.
|
||
|
||
|
||
The format for the OID is as follows:
|
||
|
||
3.4.1.6.x.y
|
||
<-----> | |
|
||
| | \
|
||
/ | job-id in the system
|
||
/ \
|
||
PML_JOB_MGNT_ROOT_OID \
|
||
job attribute 1..6
|
||
|
||
x values are 1..6:
|
||
|
||
1) user-name: user name that is obtained by the driver through some
|
||
internal method or from user input.
|
||
|
||
2) job-name: job name may be generated by the driver or obtained from
|
||
user input.
|
||
|
||
3) hold: indicates the retention classification of the job. The values
|
||
indicate whether the job is printed immediately and/or stored. There
|
||
are 4 options:
|
||
OFF: The job is printed but not retained on the disk.
|
||
ON: The job is printed and stored temporarily on the disk.
|
||
STORE: The job is not printed but stored on the disk.
|
||
PROOF: One copy of the job is printed and the remaining copies are
|
||
stored on the disk.
|
||
|
||
4) holdtype: The variable specifies the security level of the job.
|
||
PUBLIC: The job does not require a PIN in order to release the job for
|
||
printing.
|
||
PRIVATE: The job requires a PIN in order to be released for printing.
|
||
|
||
5) quantity: number of copies to print. Valid values are 0..999.
|
||
|
||
6) pin: A 4 digit string, each digit is 0-9, that is specified in the
|
||
job stream and then required to be entered in order to release the job
|
||
for printing.
|
||
|
||
y : an unsigned 15 bit number which uniquely identifies the job. The job
|
||
id for the job remains the same for the job until it is deleted from the
|
||
held jobs list.
|
||
|
||
|
||
For example, the OID below is asking for the user name of the
|
||
job whose id is 3. The application would issue:
|
||
|
||
OID
|
||
get 3.4.1.6.1.3
|
||
|
||
For example, the <getnext> OID values sequence is as follows:
|
||
|
||
OID returned OID
|
||
getnext 3.4.1.6 3.4.1.6.1.1
|
||
getnext 3.4.1.6.1.1 3.4.1.6.1.2
|
||
getnext 3.4.1.6.2.1 3.4.1.6.2.2
|
||
...
|
||
getnext 3.4.1.6.1.6 3.4.1.6.1.7
|
||
getnext 3.4.1.6.2.1 3.4.1.6.2.2
|
||
getnext 3.4.1.6.5.2828 3.4.1.6.6.1
|
||
|
||
NOTE: for example above, job id 2828 is the last job in the list of
|
||
held jobs.
|
||
...
|
||
|
||
Also supported is <getnext> on the job attributes:
|
||
OID returned OID
|
||
getnext 3.4.1.6.1 3.4.1.6.1.1
|
||
getnext 3.4.1.6.6 3.4.1.6.6.1"
|
||
::= { held-job-info 1 }
|
||
|
||
|
||
held-job-job-name OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..40))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The job name may be generated by the driver or obtained
|
||
from user input.
|
||
Additional information:
|
||
The job name may be generated by the driver or obtained
|
||
from user input."
|
||
::= { held-job-info 2 }
|
||
|
||
|
||
held-job-retention OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eHoldOff(1),
|
||
eHoldOn(2),
|
||
eHoldStore(3),
|
||
eHoldProof(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates the retention classification of the job. The
|
||
values indicate whether the job is printed immediately
|
||
and/or stored. There are 4 options:
|
||
OFF: The job is printed but not retained on the disk.
|
||
ON: The job is printed and stored temporarily on the disk.
|
||
PROOF: One copy of the job is printed and the remaining copies are stored on the disk.
|
||
STORE: The job is not printed but stored on the disk.
|
||
Additional information:
|
||
Indicates the retention classification of the job. The
|
||
values indicate whether the job is printed immediately
|
||
and/or stored. There are 4 options:
|
||
OFF: The job is printed but not retained on the disk.
|
||
ON: The job is printed and stored temporarily on the disk.
|
||
PROOF: One copy of the job is printed and the remaining copies are stored on the disk.
|
||
STORE: The job is not printed but stored on the disk."
|
||
::= { held-job-info 3 }
|
||
|
||
|
||
held-job-security OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eHoldTypePublic(1),
|
||
eHoldTypePrivate(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The variable specifies the security level of the job.
|
||
PUBLIC: The job does not require a PIN in order to release the job for printing.
|
||
PRIVATE: The job requires a PIN in order to be released for printing.
|
||
Additional information:
|
||
The variable specifies the security level of the job.
|
||
PUBLIC: The job does not require a PIN in order to release the job for printing.
|
||
PRIVATE:The job requires a PIN in order to be released for printing."
|
||
::= { held-job-info 4 }
|
||
|
||
|
||
held-job-quantity OBJECT-TYPE
|
||
SYNTAX INTEGER(1..999)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Number of copies to print.
|
||
Additional information:
|
||
Number of copies to print."
|
||
::= { held-job-info 5 }
|
||
|
||
|
||
held-job-pin OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..4))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A string that is specified in the job stream and then
|
||
required to be entered in order to release the job for
|
||
printing. PIN stands for Personal Identification
|
||
Number.
|
||
Additional information:
|
||
Must be a 4 digit string, each digit must be 0..9 or a null string
|
||
if there is no pin."
|
||
::= { held-job-info 6 }
|
||
|
||
|
||
held-job-print OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(8))
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Instructs the printer to schedule the specified held job
|
||
for printing with the specified number of copies. The
|
||
job-id is used to identify which job to print. A held
|
||
job can also be printed from the control panel.
|
||
Additional information:
|
||
Bytes 0-3 is the job id of the job to print.
|
||
Bytes 4-7 is the number of copies to print."
|
||
::= { held-job-control 1 }
|
||
|
||
|
||
held-job-delete OBJECT-TYPE
|
||
SYNTAX INTEGER(0..32768)
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Instructs the printer to delete the specified held job
|
||
from the list. The job-id is used to identify which job
|
||
to delete. A held job can also be deleted from the
|
||
control panel.
|
||
Additional information:
|
||
"
|
||
::= { held-job-control 2 }
|
||
|
||
|
||
held-job-set-queue-size OBJECT-TYPE
|
||
SYNTAX INTEGER(0..50)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Sets the maximum number of jobs which can be stored in
|
||
the held job list.
|
||
Additional information:
|
||
Sets the size of the temporary job lists queue."
|
||
::= { held-job-control 3 }
|
||
|
||
|
||
held-job-enable OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eDisabled(1),
|
||
eEnabled(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Enables or disables Job Retention (Job Hold). The valid
|
||
values are eDisabled and eEnabled. (Specifying an
|
||
invalid mode causes an <badValue>
|
||
error to be returned.) When eDisabled is specified all
|
||
Job Retention (Hold, Proof, Store, PIN Printing) is
|
||
disabled. When eEnabled is specified, the Job Retention
|
||
characteristics of a given job are defined by the PJL
|
||
variable SET HOLD.
|
||
Additional information:
|
||
When disabled, currently held jobs are not removed,
|
||
but must be explicitly removed through the Control Panel
|
||
or the PML object HELD-JOB-DELETE."
|
||
::= { held-job-control 4 }
|
||
|
||
|
||
file-system-memory OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The amount of memory, in bytes, used by the file system
|
||
to buffer file data.
|
||
Additional information:
|
||
Reports the amount of memeory, in bytes, reserved for use
|
||
by the file system. Returns status if attempting to access
|
||
this object and there is no storage device is installed.
|
||
The values remain constant across reboots. Possible values:
|
||
FILE-SYSTEM-MAX-OPEN-FILES 32 512 EIO DISK 69916 198556."
|
||
::= { settings-file-system 1 }
|
||
|
||
|
||
file-system-max-open-files OBJECT-TYPE
|
||
SYNTAX INTEGER(32..512)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The number of open files allowed at one time. Opening a
|
||
file when the maximum number of files are currently open
|
||
will fail.
|
||
Additional information:
|
||
Indicates the number of open files a personality (e.g. PCL or
|
||
PostScript) is guaranteed to be able to open before the file
|
||
system runs out of file handles. After writing this object,
|
||
the printer must be rebooted (powercycled) before the change
|
||
takes effect. This object supports any value between 32 - 512
|
||
inclusive. If a value less then 32 then it snaps to 32 if
|
||
greater than 512 it snaps to 512. The factory default value is
|
||
depentdent on the amount of installed RAM. The default value of
|
||
32 is when Memory <= 4MB, 128 is if the memory is > 4MB.
|
||
Performing a cold reset sets this object back to the factory
|
||
default value. Returns status if attempting to access this
|
||
object and there is no storage device is installed."
|
||
::= { settings-file-system 2 }
|
||
|
||
|
||
file-system-statistic-read-open OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The number of times the file system has received
|
||
requests to open a file for reading. Opening a file for
|
||
both reading and writing will cause this value to
|
||
change. The POS should state if a power cycle causes
|
||
the counter is be reset to zero.
|
||
Additional information:
|
||
Reset to the factory default value after a power cycle.
|
||
Returns status if attempting to access this object and there is
|
||
no storage device installed. This value is increamented when a
|
||
file is opened."
|
||
::= { status-file-system 1 }
|
||
|
||
|
||
file-system-statistic-write-open OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The number of times the file system has received
|
||
requests to open a file for writing. Opening a file for
|
||
both reading and writing will cause this value to
|
||
change. The POS should state if a power cycle causes
|
||
the counter is be reset to zero.
|
||
Additional information:
|
||
Reset to the factory default value after a power cycle.
|
||
Returns status if attempting to access this object and there is
|
||
no storage device installed. This value is increamented when a
|
||
file is opened."
|
||
::= { status-file-system 2 }
|
||
|
||
|
||
file-system-statistic-successful OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A counter indicating the number of file system requests
|
||
that completed successfully. The POS should state if a
|
||
power cycle causes the counter is be reset to zero.
|
||
Additional information:
|
||
Reset to the factory default value after a power cycle.
|
||
Returns status if attempting to access this object and there is
|
||
no storage device installed."
|
||
::= { status-file-system 3 }
|
||
|
||
|
||
file-system-statistic-unsuccessful OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A counter indicating the number of file system requests
|
||
that completed unsuccessfully. The POS should state if
|
||
a power cycle causes the counter is be reset to zero.
|
||
Additional information:
|
||
Reset to the factory default value after a power cycle.
|
||
Returns status if attempting to access this object and there is
|
||
no storage device is installed."
|
||
::= { status-file-system 4 }
|
||
|
||
|
||
file-system-statistic-current-memory-usage OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A value indicating the number of bytes of RAM currently
|
||
used by the file system firmware.
|
||
Additional information:
|
||
Reset to the factory default value after a power cycle.
|
||
Returns status if attempting to access this object and there
|
||
is no storage device is installed. This will vary depending
|
||
on the number and size of msss storage devices installed."
|
||
::= { status-file-system 5 }
|
||
|
||
|
||
file-system-statistic-max-memory-usage OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A value indicating the maximum number of bytes of RAM
|
||
used by the file system firmware. The POS should state
|
||
if the value is reset to zero after a power cycle.
|
||
Additional information:
|
||
Resets to the factory default value after a power cycle.
|
||
Returns status if attempting to access this object and there
|
||
is no storage device is installed."
|
||
::= { status-file-system 6 }
|
||
|
||
|
||
file-system2-initialize-volume OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eNotInitializing(1),
|
||
eInitializing(2)
|
||
}
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Setting this object to eInitializing causes file system
|
||
2 to be initialized. Reading this object indicates if
|
||
the file system is currently being initialized.
|
||
Additional information:
|
||
The hrDeviceIndex value for the mass storage device is
|
||
the same value that is used to index into the FILE-SYSTEM
|
||
sub-tree. Since this product supports only one storage device,
|
||
and since hrDeviceIndex for the mass storage devices will start
|
||
at 2 if the mass storage device is installed, the
|
||
FILE-SYSTEM2-INITIALIZE-VOLUME object will be the object that
|
||
allows the mass storage device to be installed."
|
||
::= { file-system2 6 }
|
||
|
||
|
||
error1-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error 1
|
||
occurred. Example time stamps include the actual time
|
||
the error occurred (in seconds since Jan. 1, 1970), and
|
||
the total engine page count. The device POS documents
|
||
the meaning of the time stamp.
|
||
Additional information:
|
||
In Color LaserJet8550 this item contains the engine
|
||
page count when the error occurred. A value of zero
|
||
means 'no error'.
|
||
See ERROR1-CODE for an explanation of the order used
|
||
for storing errors."
|
||
::= { error1 1 }
|
||
|
||
|
||
error1-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
Contains a device specific error code. A value
|
||
of zero means 'no error'.
|
||
|
||
The error number is returned in the upper 16 bits.
|
||
If it is 68,69,79, or 80, then the sub code is returned
|
||
in the lower 16 bits (eg. 68 0019, where the subcode is
|
||
already a hexadecimal value).
|
||
If the error number is any other number, then the 1st
|
||
sub code (XX) will be in bits 15-8 and the 2nd sub
|
||
code (YY) will be in bits 7-0 (eg. 55.04.02) where
|
||
XX=04 and YY=02).
|
||
|
||
Example: If the error is 68 001A, then the value
|
||
returned will be 4456474.
|
||
To break it down: 4456474 = 0x0044001A
|
||
The upper 16 bits: 0x0044 = 68
|
||
The lower 16 bits: 0x001A = 001A
|
||
Which is the error: 68 001A
|
||
|
||
Example: If the error is 55.04.241, then the error code
|
||
will be 3605745.
|
||
To break it down: 3605745 = 0x003704F1
|
||
The upper 16 bits: 0x0037 = 55
|
||
The upper byte of the lower 16 bits: 0x04 = 04
|
||
The lower byte of the lower 16 bits: 0xF1 = 241
|
||
Which is the error: 55.04.241
|
||
|
||
ERROR1- is the oldest error in the log. Errors are
|
||
added until ERROR50- is reached. If more errors occur,
|
||
ERROR1- is replaced by moving all error entries
|
||
down one position and adding the newest error as
|
||
ERROR50-"
|
||
::= { error1 2 }
|
||
|
||
|
||
error2-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error 2
|
||
occurred. Example time stamps include the actual time
|
||
the error occurred (in seconds since Jan. 1, 1970), and
|
||
the total engine page count. The device POS documents
|
||
the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error2 1 }
|
||
|
||
|
||
error2-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error2 2 }
|
||
|
||
|
||
error3-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error 3
|
||
occurred. Example time stamps include the actual time
|
||
the error occurred (in seconds since Jan. 1, 1970), and
|
||
the total engine page count. The device POS documents
|
||
the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error3 1 }
|
||
|
||
|
||
error3-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error3 2 }
|
||
|
||
|
||
error4-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error 4
|
||
occurred. Example time stamps include the actual time
|
||
the error occurred (in seconds since Jan. 1, 1970), and
|
||
the total engine page count. The device POS documents
|
||
the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error4 1 }
|
||
|
||
|
||
error4-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error4 2 }
|
||
|
||
|
||
error5-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error 5
|
||
occurred. Example time stamps include the actual time
|
||
the error occurred (in seconds since Jan. 1, 1970), and
|
||
the total engine page count. The device POS documents
|
||
the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error5 1 }
|
||
|
||
|
||
error5-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error5 2 }
|
||
|
||
|
||
error6-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error 6
|
||
occurred. Example time stamps include the actual time
|
||
the error occurred (in seconds since Jan. 1, 1970), and
|
||
the total engine page count. The device POS documents
|
||
the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error6 1 }
|
||
|
||
|
||
error6-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error6 2 }
|
||
|
||
|
||
error7-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error 7
|
||
occurred. Example time stamps include the actual time
|
||
the error occurred (in seconds since Jan. 1, 1970), and
|
||
the total engine page count. The device POS documents
|
||
the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error7 1 }
|
||
|
||
|
||
error7-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error7 2 }
|
||
|
||
|
||
error8-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error 8
|
||
occurred. Example time stamps include the actual time
|
||
the error occurred (in seconds since Jan. 1, 1970), and
|
||
the total engine page count. The device POS documents
|
||
the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error8 1 }
|
||
|
||
|
||
error8-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error8 2 }
|
||
|
||
|
||
error9-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error 9
|
||
occurred. Example time stamps include the actual time
|
||
the error occurred (in seconds since Jan. 1, 1970), and
|
||
the total engine page count. The device POS documents
|
||
the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error9 1 }
|
||
|
||
|
||
error9-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error9 2 }
|
||
|
||
|
||
error10-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
10 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error10 1 }
|
||
|
||
|
||
error10-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error10 2 }
|
||
|
||
|
||
error11-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
11 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error11 1 }
|
||
|
||
|
||
error11-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error11 2 }
|
||
|
||
|
||
error12-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
12 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error12 1 }
|
||
|
||
|
||
error12-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error12 2 }
|
||
|
||
|
||
error13-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
13 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error13 1 }
|
||
|
||
|
||
error13-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error13 2 }
|
||
|
||
|
||
error14-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
14 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error14 1 }
|
||
|
||
|
||
error14-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error14 2 }
|
||
|
||
|
||
error15-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
15 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error15 1 }
|
||
|
||
|
||
error15-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error15 2 }
|
||
|
||
|
||
error16-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
16 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error16 1 }
|
||
|
||
|
||
error16-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error16 2 }
|
||
|
||
|
||
error17-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
17 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error17 1 }
|
||
|
||
|
||
error17-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error17 2 }
|
||
|
||
|
||
error18-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
18 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error18 1 }
|
||
|
||
|
||
error18-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error18 2 }
|
||
|
||
|
||
error19-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
19 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error19 1 }
|
||
|
||
|
||
error19-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error19 2 }
|
||
|
||
|
||
error20-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
20 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error20 1 }
|
||
|
||
|
||
error20-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error20 2 }
|
||
|
||
|
||
error21-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
21 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error21 1 }
|
||
|
||
|
||
error21-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error21 2 }
|
||
|
||
|
||
error22-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
22 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error22 1 }
|
||
|
||
|
||
error22-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error22 2 }
|
||
|
||
|
||
error23-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
23 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error23 1 }
|
||
|
||
|
||
error23-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error23 2 }
|
||
|
||
|
||
error24-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
24 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error24 1 }
|
||
|
||
|
||
error24-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error24 2 }
|
||
|
||
|
||
error25-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
25 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error25 1 }
|
||
|
||
|
||
error25-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error25 2 }
|
||
|
||
|
||
error26-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
26 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error26 1 }
|
||
|
||
|
||
error26-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error26 2 }
|
||
|
||
|
||
error27-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
27 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error27 1 }
|
||
|
||
|
||
error27-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error27 2 }
|
||
|
||
|
||
error28-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
28 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error28 1 }
|
||
|
||
|
||
error28-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error28 2 }
|
||
|
||
|
||
error29-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
29 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error29 1 }
|
||
|
||
|
||
error29-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error29 2 }
|
||
|
||
|
||
error30-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
30 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error30 1 }
|
||
|
||
|
||
error30-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error30 2 }
|
||
|
||
|
||
error31-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
31 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error31 1 }
|
||
|
||
|
||
error31-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error31 2 }
|
||
|
||
|
||
error32-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
32 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error32 1 }
|
||
|
||
|
||
error32-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error32 2 }
|
||
|
||
|
||
error33-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
33 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error33 1 }
|
||
|
||
|
||
error33-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error33 2 }
|
||
|
||
|
||
error34-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
34 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error34 1 }
|
||
|
||
|
||
error34-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error34 2 }
|
||
|
||
|
||
error35-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
35 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error35 1 }
|
||
|
||
|
||
error35-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error35 2 }
|
||
|
||
|
||
error36-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
36 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error36 1 }
|
||
|
||
|
||
error36-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error36 2 }
|
||
|
||
|
||
error37-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
37 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error37 1 }
|
||
|
||
|
||
error37-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error37 2 }
|
||
|
||
|
||
error38-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
38 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error38 1 }
|
||
|
||
|
||
error38-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error38 2 }
|
||
|
||
|
||
error39-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
39 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error39 1 }
|
||
|
||
|
||
error39-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error39 2 }
|
||
|
||
|
||
error40-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
40 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error40 1 }
|
||
|
||
|
||
error40-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error40 2 }
|
||
|
||
|
||
error41-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
41 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error41 1 }
|
||
|
||
|
||
error41-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error41 2 }
|
||
|
||
|
||
error42-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
42 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error42 1 }
|
||
|
||
|
||
error42-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error42 2 }
|
||
|
||
|
||
error43-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
43 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error43 1 }
|
||
|
||
|
||
error43-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error43 2 }
|
||
|
||
|
||
error44-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
44 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error44 1 }
|
||
|
||
|
||
error44-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error44 2 }
|
||
|
||
|
||
error45-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
45 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error45 1 }
|
||
|
||
|
||
error45-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error45 2 }
|
||
|
||
|
||
error46-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
46 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error46 1 }
|
||
|
||
|
||
error46-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error46 2 }
|
||
|
||
|
||
error47-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
47 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error47 1 }
|
||
|
||
|
||
error47-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error47 2 }
|
||
|
||
|
||
error48-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
48 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error48 1 }
|
||
|
||
|
||
error48-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error48 2 }
|
||
|
||
|
||
error49-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
49 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error49 1 }
|
||
|
||
|
||
error49-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error49 2 }
|
||
|
||
|
||
error50-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error
|
||
50 occurred. Example time stamps include the actual
|
||
time the error occurred (in seconds since Jan. 1, 1970),
|
||
and the total engine page count. The device POS
|
||
documents the meaning of the time stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error50 1 }
|
||
|
||
|
||
error50-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS
|
||
should list what errors are logged to the error log and
|
||
the meaning of each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error50 2 }
|
||
|
||
|
||
rpc-test-return-code OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This test object that will not be supported in any
|
||
released product. Setting this object allows the next
|
||
RPC call return code to be specified. The POS will
|
||
specify the binary format.
|
||
Additional information:
|
||
The format of the binary data is a one of three formats.
|
||
The first format is no binary data, which indicates the next RPC
|
||
reply should not be modified. The other two formats are described
|
||
in RFC 1057 and encoded using XDR (i.e.e, the value is the data
|
||
used to instead of the actual RPC reply). The second format is
|
||
when reply_stat is MSG_ACCEPTED and accept_stat is something other
|
||
than SUCCESS. The third format is when reply_stat is MSG_DENIED.
|
||
Notice that all RPC replies that do not contain any 'results'
|
||
are supported."
|
||
::= { settings-rpc 1 }
|
||
|
||
|
||
rpc-bind-protocol-address OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Array of Berkeley sockets style protocol addresses used
|
||
to bind RPC to a communications protocol family.
|
||
Setting an instance of this array object to a zero
|
||
length binary value disables the transport protocol
|
||
indicated by that instance. All multi-bytes fields are
|
||
in network (or big-endian) order. Bytes 1 and 2
|
||
indicate the transport protocol. Some of the transport
|
||
protocol mapping information can be found in RFC 1010
|
||
Assigned Numbers. A list of interesting transport
|
||
protocol number mappings include:
|
||
Protocol | Number
|
||
---------+-------
|
||
UDP/IP | 17
|
||
IPX | 1000
|
||
MLC | 4660
|
||
Bytes 3 and 4 indicate the address family. The address
|
||
family uses the same mapping as the BSD sockets address
|
||
family. A list of interesting address family mappings
|
||
include:
|
||
Address Family | Number
|
||
---------------+-------
|
||
Internet | 2
|
||
NetWare | 6
|
||
MLC | 22136
|
||
The format the fifth and following bytes is dependent on
|
||
the address family. For the Internet address family,
|
||
bytes 5 and 6 contain the port number, bytes 7 through
|
||
10 contain the IP address, and the following eight bytes
|
||
are unused. For NetWare, bytes 5 through 8 are the
|
||
network number, bytes 9 through 14 are the node number,
|
||
and bytes 15 and 16 are the socket number.
|
||
Additional information:
|
||
The length of the binary value is zero if the instance of an
|
||
object in the rpc-bind-protocol-address array is not in use.
|
||
An unfortuante side effect of the implementation is initializing
|
||
the mass storage device sets this object back to the factory
|
||
default value. Returns <noSuchName> status if
|
||
attempting to access this object and there is no storage device
|
||
is installed."
|
||
::= { settings-rpc 2 }
|
||
|
||
|
||
rpc-statistic-successful OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A counter indicating the number of RPC requests that
|
||
completed successfully (reply_data stat is SUCCESS).
|
||
The POS should state if a power cycle causes the counter
|
||
is be reset to zero.
|
||
Additional information:
|
||
Reset to the factory default value after a power cycle.
|
||
Returns <noSuchName> status if
|
||
attempting to access this object and there is no storage
|
||
device is installed."
|
||
::= { status-rpc 1 }
|
||
|
||
|
||
rpc-statistic-unsuccessful OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A counter indicating the number of RPC requests that
|
||
completed unsuccessfully (reply_data stat is not
|
||
SUCCESS). The POS should state if a power cycle causes
|
||
the counter is be reset to zero.
|
||
Additional information:
|
||
Reset to the factory default value after a power cycle.
|
||
Returns <noSuchName> status if
|
||
attempting to access this object and there is no storage
|
||
device is installed."
|
||
::= { status-rpc 2 }
|
||
|
||
|
||
rpc-bound-protocol-address OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"An array of Berkeley sockets style protocol addresses
|
||
that the NFS service has been bound to successful. The
|
||
format is that same as the array of RPC-BIND-PROTOCOL-
|
||
ADDRESS of objects.
|
||
Additional information:
|
||
Returns <noSuchName> status if
|
||
attempting to access this object and there is no storage device
|
||
is installed."
|
||
::= { status-rpc 3 }
|
||
|
||
|
||
nfs-server-memory OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The amount of memory, in bytes, used by the Network File
|
||
System server to buffer file data.
|
||
Additional information:
|
||
Roports the amount of memoyr, in bytes, reserved for use by the
|
||
NFS server. An unfortunate side effect of the implementation is
|
||
initializing the mass storage device sets this object back to the
|
||
factory default value. Also includes the memory used by other
|
||
firmware components in addition to the NFS server. Returns
|
||
<noSuchName> status if attempting to access this
|
||
object and there is no storage device is installed."
|
||
::= { settings-nfs-server 1 }
|
||
|
||
|
||
nfs-server-read-size OBJECT-TYPE
|
||
SYNTAX INTEGER(256..1500)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The maximum amount of data transferred in one NFS server
|
||
read data call.
|
||
Additional information:
|
||
An unfortunate side effect of the implementation is
|
||
initializing the mass storage device sets this object back to
|
||
the factory default value. Returns status if attempting to
|
||
access this object and there is no storage device is installed.
|
||
Rebooting causes this value to reset to factory default.
|
||
Value < 256 snaps to 256 value > 1500 snaps to 1500."
|
||
::= { settings-nfs-server 2 }
|
||
|
||
|
||
nfs-server-write-size OBJECT-TYPE
|
||
SYNTAX INTEGER(256..1500)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The maximum amount of data transferred in one NFS server
|
||
write data call.
|
||
Additional information:
|
||
An unfortunate side effect of the implementation is
|
||
initializing the mass storage device sets this object bact to
|
||
the factory default value. Returns status if attempting to
|
||
access this object and there is no storage device installed."
|
||
::= { settings-nfs-server 3 }
|
||
|
||
|
||
nfs-server-test-return-code OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This test object that will not be supported in any
|
||
released product. Setting this object allows the next
|
||
NFS call return code to be specified. The POS will
|
||
specify the binary format.
|
||
Additional information:
|
||
A three byte binary value. The first byte indicates what
|
||
procedure is being effected by this set.
|
||
value | function
|
||
------+------------------
|
||
1 | GetAttr
|
||
2 | SetAttr
|
||
3 | reserved
|
||
4 | Lookup
|
||
5 | reserved
|
||
6 | Read
|
||
7 | reserved
|
||
8 | Write
|
||
9 | Create
|
||
10 | Remove
|
||
11 | Rename
|
||
12 | reserved
|
||
13 | reserved
|
||
14 | MkDir
|
||
15 | RmDir
|
||
16 | ReadDir
|
||
17 | StatFS
|
||
The second byte is the stat value returned by the next call to
|
||
procedure specified by the value of the first byte. The second
|
||
byte can not be zero. Refer to RFC 1094 for a list of stat values.
|
||
The third byte indicates which call to the specified file system
|
||
routine will fail. A value of one means the first call will fail.
|
||
A value of two means the second call will fail, and so on.
|
||
Writing this boject causes any previous write to this boject to
|
||
be invalidated."
|
||
::= { settings-nfs-server 4 }
|
||
|
||
|
||
nfs-server-statistic-successful OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A counter indicating the number of NFS requests that
|
||
completed without error. The POS should state if a
|
||
power cycle causes the counter is be reset to zero.
|
||
Additional information:
|
||
Reset to the factory default value after a power cycle.
|
||
Returns status if attempting to access this object and there
|
||
is no storage device installed."
|
||
::= { status-nfs-server 1 }
|
||
|
||
|
||
nfs-server-statistic-unsuccessful OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A counter indicating the number of NFS requests that
|
||
completed with an NFS status other than NFS_OK (0). The
|
||
POS should state if a power cycle causes the counter is
|
||
be reset to zero.
|
||
Additional information:
|
||
Reset to the factory default value after a power cycle.
|
||
Returns status if attempting to access this object and there
|
||
is no storage device installed."
|
||
::= { status-nfs-server 2 }
|
||
|
||
|
||
nfs-server-statistic-current-memory-usage OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A value indicating the number of bytes of RAM currently
|
||
used by the NFS firmware.
|
||
Additional information:
|
||
Resets to the factory default value after a power cycle.
|
||
Returns status if attempting to access this object and there
|
||
is no storage device is installed."
|
||
::= { status-nfs-server 4 }
|
||
|
||
|
||
nfs-server-statistic-max-memory-usage OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A value indicating the maximum number of bytes of RAM
|
||
used by the NFS firmware. The POS should state if the
|
||
value is reset to zero after a power cycle.
|
||
Additional information:
|
||
Resets to the factory default value after a power cycle.
|
||
Returns status if attempting to access this object and there
|
||
is no storage device is installed."
|
||
::= { status-nfs-server 5 }
|
||
|
||
|
||
rpc-bind-test-return-code OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This test object that will not be supported in any
|
||
released product. Setting this object allows the next
|
||
RPC bind call return code to be specified. The POS will
|
||
specify the binary format.
|
||
Additional information:
|
||
A one byte value.
|
||
value | meaning
|
||
------+-----------------------
|
||
1 | Next GetPort or GetAddr will receive port 0
|
||
| (indicating the service is not supported).
|
||
2 | Next Dump will receive an empty table."
|
||
::= { settings-rpc-bind 1 }
|
||
|
||
|
||
rpc-bind-statistic-successful OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A counter indicating the number of RPC bind (RPC program
|
||
number 100000, version 2) requests that completed
|
||
successfully. The POS should state if a power cycle
|
||
causes the counter is be reset to zero.
|
||
Additional information:
|
||
Reset to the factory default value after a power cycle.
|
||
Returns <noSuchName> status if
|
||
attempting to access this object and there is no storage
|
||
device is installed."
|
||
::= { status-rpc-bind 1 }
|
||
|
||
|
||
rpc-bind-statistic-unsuccessful OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A counter indicating the number of RPC bind (RPC program
|
||
number 100000, version 2) requests that completed
|
||
unsuccessfully. The POS should state if a power cycle
|
||
causes the counter is be reset to zero.
|
||
Additional information:
|
||
Reset to the factory default value after a power cycle.
|
||
Returns <noSuchName> status if
|
||
attempting to access this object and there is no storage
|
||
device is installed."
|
||
::= { status-rpc-bind 2 }
|
||
|
||
|
||
xip-statistic-processed OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A counter indicating the number of XIP requests that
|
||
were processed. The POS should state if a power cycle
|
||
causes the counter is be reset to zero.
|
||
Additional information:
|
||
The number of XIP datagrams that have been received by the
|
||
XIP service. Reset to the factory default value after a power cycle.
|
||
Returns <noSuchName> status if
|
||
attempting to access this object and there is no storage device
|
||
is installed."
|
||
::= { status-xip 1 }
|
||
|
||
|
||
xip-statistic-data-in-dropped OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A counter indicating the number of XIP data in datagrams
|
||
that were dropped (typically due to the printer being
|
||
flooded with XIP requests ). The POS should state if a
|
||
power cycle causes the counter is be reset to zero.
|
||
Additional information:
|
||
Reset to the factory default value after a power cycle.
|
||
Returns <noSuchName> status if
|
||
attempting to access this object and there is no storage device
|
||
is installed."
|
||
::= { status-xip 2 }
|
||
|
||
|
||
io-timeout OBJECT-TYPE
|
||
SYNTAX INTEGER(5..300)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The amount of time, in seconds, to wait for more print
|
||
job data to be received before an I/O timeout occurs.
|
||
The I/O channel being timed is the I/O channel that
|
||
received the data associated with the current print job.
|
||
If an I/O timeout occurs, the PDL processing sub-system
|
||
assumes all the data associated with the current print
|
||
job has been received, and processes the end of job in
|
||
an PDL specific manner. The POS specifies the supported
|
||
values.
|
||
Additional information:
|
||
If an I/O timeout occurs, the PDL processing
|
||
sub-system will consider it an end of job condition
|
||
only if there is data from another I/O subsystem
|
||
waiting to be processed.
|
||
The suppurted values are 5 to 300 seconds and
|
||
the step size is 10 seconds.
|
||
Setting to a value outside the supported range returns
|
||
<badValue> status and the value
|
||
will be snapped to the nearest supported value."
|
||
::= { settings-io 1 }
|
||
|
||
|
||
io-switch OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eYes(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates if the device will switch between I/O channels
|
||
when a job boundary is encountered and print job data is
|
||
available on another I/O channel."
|
||
::= { settings-io 2 }
|
||
|
||
|
||
io-buffering OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eAuto(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or controls the manner in which the device
|
||
performs I/O data buffering. I/O data buffering allows
|
||
additional print job data to be buffered by the I/O sub-
|
||
system in an effort to allow the computer sending the
|
||
data to perform other tasks and to keep the PDL
|
||
processing sub-system busy. eOff, I/O buffering is
|
||
disabled. When eOn, I/O buffering is enabled and the
|
||
IO-BUFFER-SIZE object controls the amount of memory set
|
||
aside for I/O buffer. When eAuto, I/O buffering is
|
||
enabled and the I/O buffer size is determined
|
||
automatically by the device and the IO-BUFFER-SIZE
|
||
object is not used.
|
||
Additional information:
|
||
When eAuto, I/O buffering is enabled and the I/O
|
||
buffer size is determined automatically by the device and
|
||
the IO-BUFFER-SIZE object is not used."
|
||
::= { settings-io 5 }
|
||
|
||
|
||
io-buffer-size OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or configures the amount of memory, in bytes,
|
||
dedicated to I/O print job data buffering. Attempting
|
||
to set to an unsupported value causes the device to use
|
||
the closest supported value. Each device POS should
|
||
document the list of supported values.
|
||
Additional information:
|
||
When IO-BUFFERING is eAuto, the printer determines
|
||
the value of this object. Reading this object when
|
||
IO-BUFFERING is eAuto will return the value that is currently
|
||
being used by the printer.
|
||
The minimum value is 10240; the maximum value is the current
|
||
value of this object plus the value of
|
||
MAXIMUM-IO-BUFFERING-MEMORY. Supported values are multiples of
|
||
10240 for values less or equal to 97280 and multiples of 102400
|
||
for values greater than 97280. "
|
||
::= { settings-io 6 }
|
||
|
||
|
||
maximum-io-buffering-memory OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object's name is misleading. Returns the maximum
|
||
amount of additional memory, in bytes, that can be
|
||
dedicated to buffering print job data.
|
||
Additional information:
|
||
Memory for I/O Buffering is allocated in increments of
|
||
102400 bytes. Therefore, for each 1M (1048576 bytes) of memory
|
||
added to the printer, 1024000 bytes are made available to
|
||
resource saving (and I/O buffering) and 24576 bytes are
|
||
retained until an additional 102400 byte block can be made
|
||
available. The value reported by this object is always
|
||
rounded down to the nearest multiple of 102400."
|
||
::= { settings-io 7 }
|
||
|
||
|
||
port1-parallel-speed OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eFast(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or changes the maximum parallel I/O port speed,
|
||
for port 1. This object is only supported if this port
|
||
is a parallel port. An eSlow setting causes a 10 us
|
||
busy pulse per received byte of data. An eFast setting
|
||
causes a 1.5 us busy pulse per received byte of data.
|
||
In rare cases, setting this value to eFast can cause the
|
||
parallel port to no longer transfer data reliably.
|
||
Additional information:
|
||
Returns the maximum parallel I/O port speed,
|
||
for port 1. This object is only supported if this port
|
||
is a parallel port. An eFast setting causes a 1.5 us
|
||
busy pulse per received byte of data. In rare cases,
|
||
eFast can cause the parallel port to no longer transfer
|
||
data reliably. "
|
||
::= { port1 4 }
|
||
|
||
|
||
port1-parallel-bidirectionality OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eBidirectional(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or changes whether the parallel I/O port
|
||
supports bidirectional communication for port 1. This
|
||
object is only supported if this port is a parallel
|
||
port.
|
||
Additional information:
|
||
Color LaserJet8550 will always be bi-directional. Thus, having
|
||
this object here doesn't mean much...
|
||
A get on this object returns the current mode for the parallel
|
||
port."
|
||
::= { port1 5 }
|
||
|
||
|
||
default-copies OBJECT-TYPE
|
||
SYNTAX INTEGER(1..999)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or changes default copies. Default copies is
|
||
the default values used by the PDL to control the number
|
||
of copies of each page in the print job that are
|
||
printed. The print job can override this value. The
|
||
list of supported values should be documented in the
|
||
device POS.
|
||
Additional information:
|
||
The supported values are 1
|
||
through 999. Setting to an unsupported value causes
|
||
the printer to substitute in a snap value
|
||
and to return
|
||
<noError> status.
|
||
The snap values are as follow:
|
||
<1 snaps to 1
|
||
>999 snaps to 999"
|
||
::= { settings-pdl 4 }
|
||
|
||
|
||
resource-saving OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eAuto(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or changes PDL resource saving. Resource saving
|
||
stores a PDL's permanent soft resources, like fonts,
|
||
even when another PDL is active. Resource saving is
|
||
also called environment saving. When eOff, resource
|
||
saving is disabled. When ON, resource saving is enabled
|
||
and memory is set aside for each PDL based on that PDL's
|
||
resource saving memory size object, to store that PDL's
|
||
permanent soft resources. When eAuto, resource saving
|
||
is enabled and memory space for each installed PDL is
|
||
determined automatically. The device POS should
|
||
document what values are legal when only one PDL is
|
||
installed.
|
||
Additional information:
|
||
Color LaserJet8550 only supports eAuto. Thus memory space for
|
||
each installed PDL is determined automatically."
|
||
::= { settings-pdl 6 }
|
||
|
||
|
||
maximum-resource-saving-memory OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object's name is misleading. This object returns
|
||
the maximum amount of additional memory, in bytes, that
|
||
can be dedicated to holding PDL permanent soft
|
||
resources.
|
||
Additional information:
|
||
Base memory for Color LaserJet8550 is 32MB.
|
||
Memories for PostScript and PCL are 3MB and 4MB
|
||
respectively. However, for every 8MB increment,
|
||
0.5MB is added to each PDL.
|
||
(((64 * 8) - 32) / 8) / 0.5 = 30MB.
|
||
Thus, total memories for PostScript and PCL are 33MB
|
||
and 34MB respectively."
|
||
::= { settings-pdl 7 }
|
||
|
||
|
||
default-vertical-black-resolution OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or changes the value of the default vertical
|
||
black resolution. The units are dots per inch.
|
||
Additional information:
|
||
In Color LaserJet8550 changing this OID also causes
|
||
DEFAULT-HORIZONTAL-BLACK-RESOLUTION to change.
|
||
DEFAULT-HORIZONTAL-BLACK-RESOLUTION and
|
||
DEFAULT-VERTICAL-BLACK-RESOLUTION must always be
|
||
the same. The supported value is 600.
|
||
Setting to an unsupported value causes the printer
|
||
to substitute in a snap value and to return
|
||
<noError> status.
|
||
< 300 snap to 600
|
||
>= 300 snap to 600"
|
||
::= { settings-pdl 8 }
|
||
|
||
|
||
default-horizontal-black-resolution OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or changes the value of the default horizontal
|
||
black resolution. The units are dots per inch.
|
||
Additional information:
|
||
In Color LaserJet8550 changing this OID also causes
|
||
DEFAULT- VERTICAL-BLACK RESOLUTION to change.
|
||
DEFAULT- HORIZONTAL-BLACK-RESOLUTION and
|
||
DEFAULT-VERTICAL-BLACK-RESOLUTION must always be the
|
||
same. The supported value is 600.
|
||
Setting to an unsupported value causes the printer
|
||
to substitute in a snap value and to
|
||
return <noError> status.
|
||
The snap values are as follow:
|
||
< 300 snap to 600
|
||
>= 300 snap to 600"
|
||
::= { settings-pdl 9 }
|
||
|
||
|
||
default-page-protect OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eAuto(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or changes the default page protection behavior.
|
||
If eOff, the device does not reserve memory for holding
|
||
the entire raster form of a processed page. If eOn,
|
||
then memory is reserved. If eAuto, the device
|
||
determines the amount of memory to reserve.
|
||
Additional information:
|
||
In eAuto, the device determines the amount of
|
||
memory to reserve.
|
||
Color LaserJet8550 doesn't need to support this object.
|
||
Thus, this object being here does not convey
|
||
much meaning."
|
||
::= { settings-pdl 10 }
|
||
|
||
|
||
default-lines-per-page OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or changes the default number of lines per page.
|
||
The POS indicates the supported values. An unsupported
|
||
value causes the printer to use the closest supported
|
||
value, causing the printer to return the
|
||
<noError>.
|
||
Additional information:
|
||
The supported values in Color LaserJet8550 are 5 to 128.
|
||
Setting to an unsupported value causes the
|
||
the printer to substitute in a snap value and to return
|
||
<noError> status.
|
||
The snap values are as follow:
|
||
<5 snaps to 5
|
||
>128 snaps to 128"
|
||
::= { settings-pdl 11 }
|
||
|
||
|
||
default-vmi OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or changes the default vertical motion index.
|
||
The unit of measure for VMI is centipoints per line.
|
||
The POS indicates the supported values. An unsupported
|
||
value causes the printer to use the closest supported
|
||
value, causing the printer to return
|
||
<noError>."
|
||
::= { settings-pdl 12 }
|
||
|
||
|
||
default-media-size OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eUSExecutive(1),
|
||
eUSLetter(2),
|
||
eUSLegal(3),
|
||
eLedger(11),
|
||
eISOandJISA5(25),
|
||
eISOandJISA4(26),
|
||
eISOandJISA3(27),
|
||
eJISB5(45),
|
||
eJISB4(46),
|
||
eJapanesePostcardDouble(72),
|
||
eMonarch(80),
|
||
eCommercial10(81),
|
||
eInternationalDL(90),
|
||
eInternationalC5(91),
|
||
eInternationalB5(100)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This indicates the default media size. A write of an
|
||
unsupported value causes an <badValue>.
|
||
Complete list of supported media sizes along
|
||
with their dimensions are listed in the ''Media Size
|
||
Table'' near the end of this document."
|
||
::= { settings-pdl 13 }
|
||
|
||
|
||
cold-reset-media-size OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eUSLetter(2),
|
||
eISOandJISA4(26)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or sets the media size that is used as the
|
||
DEFAULT-MEDIA-SIZE when a cold reset occurs."
|
||
::= { settings-pdl 19 }
|
||
|
||
|
||
default-media-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or sets the media name that is used until the
|
||
media name is changed by a print job command.
|
||
Additional information:
|
||
This string must be one of the
|
||
MEDIAn-NAME objects."
|
||
::= { settings-pdl 22 }
|
||
|
||
|
||
form-feed-needed OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eFalse(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates if the PDL processing sub-system has made
|
||
marks on the current page and the source subsystem has
|
||
been idle for a device specific amount of time.
|
||
Additional information:
|
||
This object in Color LaserJet8550 will never go to true."
|
||
::= { status-pdl 2 }
|
||
|
||
|
||
pcl-resource-saving-memory-size OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or changes the amount of resource saving memory
|
||
set aside to hold permanent soft PCL resources.
|
||
Additional information:
|
||
The value returned by this object is the amount of
|
||
Resource Saving memory currently dedicated to PCL.
|
||
If a value is received that is between 1 and 409599, it will be
|
||
snapped to 409600 and a status of
|
||
<noError> returned.
|
||
If an unsupported value greater than 409600 is received,
|
||
it will be snapped down to the nearest 102400 value
|
||
and a status of <noError> returned."
|
||
::= { pdl-pcl 2 }
|
||
|
||
|
||
pcl-total-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Total number of PCL pages printed by the device.
|
||
Additional information:
|
||
In Color LaserJet8550 the PCL page count is kept in NVRAM
|
||
however the NVRAM value is only updated every
|
||
10 pages.
|
||
NOTE: The value returned by this OID will be
|
||
incremented every page but if power is lost between
|
||
NVRAM updates, up to 9 pages of the page count may be
|
||
lost. The page count counter will be reset to zero
|
||
after 16,777,215 (2^24-1) pages.
|
||
The page count is incremented when a sheet of media is
|
||
pulled from an input tray. A duplex printed sheet will
|
||
cause this counter to be incremented by two."
|
||
::= { pdl-pcl 5 }
|
||
|
||
|
||
pcl-default-font-height OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or changes the default PCL height. Height is an
|
||
approximate measure of the body of the type in
|
||
centipoints. A centipoint is 1/7200 inch. Height
|
||
applies only to proportional fonts. Point size, in
|
||
points, can be converted to font height, in centipoints,
|
||
by multiplying the point size by 100. The POS indicates
|
||
the supported values. An unsupported value causes the
|
||
printer to use the closest supported value, causing the
|
||
printer to return <noError>.
|
||
''Closest'' means the smallest absolute difference.
|
||
Additional information:
|
||
Supported values range from 400 to 99975, in
|
||
increments of 25 units.
|
||
Setting to an unsupported value causes the
|
||
printer to substitute in a snap value and to
|
||
return <noError> status.
|
||
The snap values are as follow:
|
||
<=400 snaps to 400
|
||
>=99975 snaps to 99975
|
||
Unsupported values in the range 400 to 99975 snaps
|
||
DOWN to the previous supported value
|
||
(i.e 25293 snaps to 25275 or 75038 snaps to 75025)."
|
||
::= { pdl-pcl 13 }
|
||
|
||
|
||
pcl-default-font-source OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eInternal(1),
|
||
ePermanentSoft(2),
|
||
eRomSimm1(10),
|
||
eRomSimm2(11),
|
||
eRomSimm3(12),
|
||
eRomSimm4(13)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or changes the value of the default font source
|
||
variable in NVRAM."
|
||
::= { pdl-pcl 14 }
|
||
|
||
|
||
pcl-default-font-number OBJECT-TYPE
|
||
SYNTAX INTEGER(0..999)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or changes the value of the default font number
|
||
variable in NVRAM. Writing an unsupported value causes
|
||
the printer to generate an
|
||
<badValue>."
|
||
::= { pdl-pcl 15 }
|
||
|
||
|
||
pcl-default-font-width OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or changes the default PCL font width. Width is
|
||
expressed as the width of a character in centipoints. A
|
||
centipoint is 1/7200 inch. Width applies only to fixed
|
||
space fonts. Pitch, in character per inch, can be
|
||
converted to font width, in centipoints, by dividing
|
||
7200 by the pitch. The POS indicates the supported
|
||
values. An unsupported value causes the printer to use
|
||
the closest supported value, causing the printer to
|
||
return <noError>. ''Closest''
|
||
means the smallest absolute difference.
|
||
Additional information:
|
||
Setting to an unsupported value causes the
|
||
printer to substitute in a snap value (listed below)
|
||
and to return <noError> status.
|
||
The snap values are as follow:
|
||
<=44 snaps to 44
|
||
>=9999 snaps to 9999"
|
||
::= { pdl-pcl 16 }
|
||
|
||
|
||
postscript-resource-saving-memory-size OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or changes the amount of resource saving memory
|
||
set aside to hold permanent soft PostScript resources.
|
||
Additional information:
|
||
The value returned by this object is the amount of
|
||
Resource Saving memory currently dedicated to PostScript.
|
||
If a value is received that is between 1 and 409599, it will
|
||
be snapped to 409600 and a status of
|
||
<noError> returned.
|
||
If an unsupported value greater than 409600 is received,
|
||
it will be snapped down to the nearest 102400 value
|
||
and a status of <noError> returned."
|
||
::= { pdl-postscript 2 }
|
||
|
||
|
||
postscript-total-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Total number of PostScript pages printed by the device.
|
||
Additional information:
|
||
In Color LaserJet8550 the count is kept in NVRAM however the
|
||
NVRAM value is only updated every 10 sheets.
|
||
NOTE: The value returned by this OID will be
|
||
incremented every sheet but if power is lost between
|
||
NVRAM updates up to 9 sheets of the count may be
|
||
lost. The counter will be reset to zero
|
||
after 16,777,215 (2^24-1) pages. "
|
||
::= { pdl-postscript 5 }
|
||
|
||
|
||
postscript-print-errors OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eOff(1),
|
||
eOn(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or changes the value of the print PostScript
|
||
errors setting. If eOn, PostScript prints an error page
|
||
showing the error encountered and the stack at the time
|
||
of the error."
|
||
::= { pdl-postscript 11 }
|
||
|
||
|
||
postscript-jam-recovery OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eOn(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or changes the PostScript jam recovery setting.
|
||
If eOn, then the device will reprint PostScript pages,
|
||
if those pages jam.
|
||
Additional information:
|
||
Returns the Postscript jam recovery setting.
|
||
If eOn, then the device will reprint PostScript pages,
|
||
if those pages jam."
|
||
::= { pdl-postscript 12 }
|
||
|
||
|
||
pjl-password OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns PJL password, if the password is not set (zero).
|
||
If the password is set, then attempting to retrieve the
|
||
password causes an <genErr> to occur
|
||
and will return the <NullValue>."
|
||
::= { pjl 1 }
|
||
|
||
|
||
jetsend-mode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eOff(1),
|
||
eOn(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Enables or disables the JetSend processing sub-system.
|
||
Additional information:
|
||
Enables or disables the JetSend processing subsystem.
|
||
The valid values are eOff and eOn.
|
||
(Specifying an invalid mode causes an
|
||
<badValue> error to be returned.)"
|
||
::= { settings-jetsend 1 }
|
||
|
||
|
||
jetsend-contact-password OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A C structure containing the following fields:
|
||
typedef struct {
|
||
ubyte old_password[8];
|
||
ubyte new_password[8];/
|
||
} jetsend_change_contact_password_t;
|
||
where ubyte is an unsigned byte (0-255).
|
||
Additional information:
|
||
Controls access to the JetSend processing subsystem.
|
||
Password absence/presence determines whether the device
|
||
will allow a session to be established. The following C
|
||
data structure contains the relevant fields (described in
|
||
subsequent paragraphs):
|
||
typedef struct {
|
||
unsigned char old_password[8];
|
||
unsigned char new_password[8]; }
|
||
Whenever the password is disabled (i.e., is zero-filled
|
||
for its entire length), the device is indicating its
|
||
willingness to allow session establishment. Whenever the
|
||
password is enabled (i.e., has one or more non-zero-filled
|
||
values), the device is controlling session establishment --
|
||
all in-progress JetSend sessions must supply a matching
|
||
password or the device will reject the in-progress session.
|
||
To disable the password, specify the matching password via the
|
||
'old_password' field and zero-fill the 'new_password' field.
|
||
To enable the password for the first time, zero-fill the
|
||
'old_password' field and specify the new password via the
|
||
'new_password' field (the new password should not be
|
||
zero-filled; otherwise, the password will remain disabled).
|
||
To enable or change the password thereafter, specify the
|
||
matching password via the 'old_password' field and specify
|
||
the new password via the 'new_password' field (the new desired
|
||
password should not be zero-filled; otherwise, the password
|
||
will be disabled).
|
||
To determine if the password is enabled, zero-fill both the
|
||
'old_password' and 'new_password' fields. If an error occurs,
|
||
the password is enabled; otherwise, the password is disabled.
|
||
(Specifying either an 'old_password' or 'new_password' fields
|
||
greater than eight (8) bytes causes the error
|
||
<badValue> to be returned.)"
|
||
::= { settings-jetsend-contact 1 }
|
||
|
||
|
||
jetsend-contact-ip-address-security OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A C structure containing the following fields:
|
||
typedef struct {
|
||
ubyte reserved[3];
|
||
ubyte command; /* command: 0 to 1 */
|
||
ubyte password[8];
|
||
ubyte IPAddress[4];
|
||
} jetsend_contact_ip_address_security_t;
|
||
where ubyte is an unsigned byte (0-255). The defined
|
||
values defined for command are:
|
||
|
||
When command is 0:
|
||
IPAddress is 0: device is locked, no one can contact
|
||
it
|
||
IPAddress is > 0: only that address is allowed to
|
||
contact the device
|
||
|
||
When command is 1:
|
||
IPAddress is 0: any device can contact it
|
||
IPAddress is > 0: any device matching this mask can
|
||
contact it. If the result of logically anding the mask
|
||
value supplied in the IPAddress field with the sending
|
||
device's IP address matches the result of logically
|
||
anding the mask value supplied in the IPAddress field
|
||
with this device's IP address, then JetSend will allow
|
||
the session to be established.
|
||
Additional information:
|
||
Controls the device or class of device(s) which may
|
||
communicate with the JetSend processing subsystem.
|
||
The following C data structure contains the relevant fields
|
||
(described in subsequent paragraphs):
|
||
typedef struct {
|
||
unsigned char reserved[3];
|
||
unsigned char command;
|
||
unsigned char password[8];
|
||
unsigned char IPAddress[4]; }
|
||
The 'reserved' field is not used and should remain zero-filled.
|
||
|
||
The 'command' field interpretation differs based on its value:
|
||
0 = Accept session(s) only from the specific device whose IP
|
||
address matches the specified IP address; all other session
|
||
request(s) from non-matching device(s) are rejected. 1 = Accept
|
||
session(s) only from the specific device(s) whose IP
|
||
address(es) conform to the mask specified in the 'IPAddress'
|
||
field; all other session request(s) from device(s) with
|
||
non-matching submask(s) are rejected. (If the result of
|
||
logically AND'ing the mask value supplied in the 'IPAddress'
|
||
field with the sending device's IP address matches the result
|
||
of logically AND'ing the mask value supplied in the 'IPAddress'
|
||
field with this device's IP address, then JetSend will allow
|
||
session establishment.
|
||
Password absence/presence determines whether the device will
|
||
allow the caller to alter the IP address security.
|
||
If the password is disabled, the caller may set the 'command'
|
||
and 'IPAddress' fields directly. If the password is enabled,
|
||
the caller may (re-)set the 'command' and 'IPAddress' fields
|
||
only after specifying the matching 'password' field. (Refer to
|
||
the aforementioned 'JETSEND-CONTACT-PASSWORD' object ID.)
|
||
(Specifying either an invalid 'command' field value or a
|
||
'password' field greater than eight (8) bytes or an 'IPAddress'
|
||
field greater than four (4) bytes causes the error
|
||
<badValue> to be returned.)"
|
||
::= { settings-jetsend-contact 2 }
|
||
|
||
|
||
total-color-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER(0..4294967296)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Total number of color pages printed by the device.
|
||
Additional information:
|
||
Any page with one or more color pixels is counted as
|
||
a color page. Pages that only contain black marks are not
|
||
counted by this object.
|
||
The counter will roll over to zero after 4,294,967,296 pages.
|
||
Each side of a duplexed sheet of media will be counted
|
||
independently based on the criteria listed above."
|
||
::= { status-prt-eng 7 }
|
||
|
||
|
||
duplex-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Total number of sheets of media that have been duplex
|
||
printed. A sheet is counted if it travels through the
|
||
duplex page path, regardless of whether or not marks are
|
||
made on the page. The POS will indicate if the value is
|
||
kept in NVRAM.
|
||
Additional information:
|
||
In Color LaserJet8550 the count is kept in
|
||
NVRAM however the NVRAM value is only updated every 10
|
||
sheets. NOTE: The value returned by this OID will be
|
||
incremented every sheet but if power is lost between
|
||
NVRAM updates up to 9 sheets of the count may be
|
||
lost. The counter will be reset to zero
|
||
after 16,777,215 (2^24-1) pages. "
|
||
::= { status-prt-eng 22 }
|
||
|
||
|
||
mp-tray OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eCassette(2),
|
||
eFirst(3)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or changes the value of the multi-purpose (MP)
|
||
tray configuration variable. The MP tray can be
|
||
configured to operate as an additional input tray
|
||
(eCassette), a manual feed slot (eManual), or in a
|
||
manner compatible with the LaserJet III manual feed slot
|
||
(eFirst). If configured for eFirst, if media is present
|
||
in the MP tray, that media is used (assuming the size
|
||
matches and the print job didn't specify another tray)
|
||
until the MP tray is empty."
|
||
::= { settings-intray 5 }
|
||
|
||
|
||
custom-paper-dim-unit OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eTenThousandthsOfInches(3),
|
||
eMicrometers(4)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The units of measure used to specify the width and
|
||
height of the printer's custom paper. The unit of
|
||
measure of eTenThousandthsOfInches is 0.0001 inches.
|
||
Additional information:
|
||
The only valid values for this object are
|
||
eTenThousandthsOfInches (3), and eMicrometers (4).
|
||
The data for this object is stored in NVRAM."
|
||
::= { settings-intray 7 }
|
||
|
||
|
||
custom-paper-feed-dim OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Sets the printer's custom paper dimension in the feed
|
||
direction (direction parallel to the direction of paper
|
||
feeding). The value for this object is specified in
|
||
micrometers or tenthousandths of an inch, depending upon
|
||
the value of CUSTOM-PAPER-DIM-UNIT. The valid range is
|
||
engine-dependent and should be documented in the POS for
|
||
each product.
|
||
Additional information:
|
||
The valid range for Color LaserJet8550 is 75000 to 177000 if
|
||
CUSTOM-PAPER-DIM-UNIT is eTenthousandthoOfInches or
|
||
190500 to 449580 if CUSTOM-APPER-DIM-UNIT is
|
||
eMicrometers. Attempts to set this object outside the valid
|
||
range will result in a return value of
|
||
<badValue>. The data for this object
|
||
is stored in NVRAM."
|
||
::= { settings-intray 8 }
|
||
|
||
|
||
custom-paper-xfeed-dim OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Sets the printer's custom paper dimension in the cross-
|
||
feed direction (direction ninety degrees relative to the
|
||
direction of paper feeding). The value for this object
|
||
is specified in micrometers or tenthousandths of an
|
||
inch, depending upon the value of CUSTOM-PAPER-DIM-UNIT.
|
||
The valid range is engine-dependent and should be
|
||
documented in the POS for each product.
|
||
Additional information:
|
||
The valid range for Color LaserJet8550 is 36700 to 117000 if
|
||
CUSTOM-PAPER-DIM-UNIT is eTenthousandthoOfInches or
|
||
93218 to 297180 if CUSTOM-APPER-DIM-UNIT is
|
||
eMicrometers. Attempts to set this object outside the valid
|
||
range will result in a return value of
|
||
<badValue>. The data for this object
|
||
is stored in NVRAM."
|
||
::= { settings-intray 9 }
|
||
|
||
|
||
tray1-media-size-loaded OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eUSExecutive(1),
|
||
eUSLetter(2),
|
||
eUSLegal(3),
|
||
eLedger(11),
|
||
eISOandJISA5(25),
|
||
eISOandJISA4(26),
|
||
eISOandJISA3(27),
|
||
eJISB5(45),
|
||
eJISB4(46),
|
||
eJapansePostcardDouble(72),
|
||
eMonarch(80),
|
||
eCommercial10(81),
|
||
eInternationalDL(90),
|
||
eInternationalC5(91),
|
||
eInternationalB5(100),
|
||
eCustom(101)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the media size that is currently
|
||
configuredconfigured in tray #1. This object can be set
|
||
to indicate the media size currently loaded, if the
|
||
printer supports input trays that can not sense the
|
||
media size. Complete list of supported media sizes
|
||
along with their dimensions are listed in the ''Media
|
||
Size Table'' near the end of this document.
|
||
Additional information:
|
||
Returns the media size that is currently configured
|
||
in tray #1. This object can be set to indicate
|
||
the media size currently loaded, if the printer
|
||
supports input trays that cannot sense the media
|
||
size. Complete list of supported media sizes along
|
||
with their dimensions are listed in the 'Media
|
||
Size Table' near the end of this document.
|
||
This tray is built in and therefore, always installed."
|
||
::= { intray1 1 }
|
||
|
||
|
||
tray1-phd OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Provides the number of the Paper Handling Device that
|
||
contains this input tray."
|
||
::= { intray1 12 }
|
||
|
||
|
||
tray2-media-size-loaded OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eUSLetter(2),
|
||
eUSLegal(3),
|
||
eISOandJISA4(26),
|
||
eJISB4(46)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the media size that is currently configured in
|
||
tray #2. Complete list of supported media sizes along
|
||
with their dimensions are listed in the ''Media Size
|
||
Table'' near the end of this document.
|
||
Additional information:
|
||
If the tray drawer is open, a get on this object will
|
||
cause a status of <genErr>
|
||
to be returned. If the tray is empty, the size that
|
||
the tray is configured for will be returned."
|
||
::= { intray2 1 }
|
||
|
||
|
||
tray2-phd OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Provides the number of the Paper Handling Device that
|
||
contains this input tray."
|
||
::= { intray2 12 }
|
||
|
||
|
||
tray3-media-size-loaded OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eUSLetter(2),
|
||
eUSLegal(3),
|
||
eLedger(11),
|
||
eISOandJISA3(27),
|
||
eISOandJISA4(26),
|
||
eJISB4(46)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the media size that is currently configured in
|
||
tray #3. Complete list of supported media sizes along
|
||
with their dimensions are listed in the ''Media Size
|
||
Table'' near the end of this document.
|
||
Additional information:
|
||
The Media Size Table does not exist in this document."
|
||
::= { intray3 1 }
|
||
|
||
|
||
tray3-phd OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Provides the number of the Paper Handling Device that
|
||
contains this input tray."
|
||
::= { intray3 12 }
|
||
|
||
|
||
tray4-media-size-loaded OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eUSLetter(2),
|
||
eUSLegal(3),
|
||
eLedger(11),
|
||
eISOandJISA3(27),
|
||
eISOandJISA4(26),
|
||
eJISB4(46)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the media size that is currently configured in
|
||
tray #4. Complete list of supported media sizes along
|
||
with their dimensions are listed in the ''Media Size
|
||
Table'' near the end of this document.
|
||
Additional information:
|
||
The Media Size Table does not exist in this document.
|
||
Attempting to access this object when the tray is not installed
|
||
will result in an ErrorUnknownObjectIdentifier response from
|
||
the printer."
|
||
::= { intray4 1 }
|
||
|
||
|
||
tray4-phd OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Provides the number of the Paper Handling Device that
|
||
contains this input tray."
|
||
::= { intray4 12 }
|
||
|
||
|
||
tray5-phd OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Provides the number of the Paper Handling Device that
|
||
contains this input tray."
|
||
::= { intray5 12 }
|
||
|
||
|
||
overflow-bin OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or sets the bin that will be used for additional
|
||
sheets of media when the current bin is full and
|
||
printing is allowed to continue.
|
||
Additional information:
|
||
If this object is set to zero, overflowing to another
|
||
bin is not allowed."
|
||
::= { settings-outbin 4 }
|
||
|
||
|
||
outbin1-override-mode OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or sets the device behavior when this output bin
|
||
condition causes printing to stop.
|
||
cCancelJob - The device cancels the job.
|
||
cOutbinFullOverride - The device sends subsequent
|
||
media to the overflow bin.
|
||
cOutbinAttentionOverride - The device ignores the
|
||
attention condition and continues printing.
|
||
cBinderAttentionOverride - The device ignores the
|
||
binder attention condition and continues printing.
|
||
Additional information:
|
||
If cCancelJob is set, the current print job
|
||
will be cancelled regardless of other item settings.
|
||
If cOutbinFullOverride is set and this bin is the
|
||
designated overflow bin (OVERFLOW-BIN = 1), then
|
||
the bit is ignored. This object describes the action
|
||
that is performed when the
|
||
JOB-OUTPUT-AUTO-CONTINUE-TIMEOUT expires. If no bits
|
||
are set, no override action is taken (the printer will
|
||
continue to wait). The action performed by the
|
||
CONTINUE object being set to eInitiateAction or the GO
|
||
key being pressed on the control panel may cause
|
||
different actions. See the
|
||
CONTINUE object description for information on the
|
||
actions that occur for those conditions."
|
||
::= { outbin1 9 }
|
||
|
||
|
||
outbin2-override-mode OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or sets the device behavior when this output bin
|
||
condition causes printing to stop.
|
||
cCancelJob - The device cancels the job.
|
||
cOutbinFullOverride - The device sends subsequent
|
||
media to the overflow bin.
|
||
cOutbinAttentionOverride - The device ignores the
|
||
attention condition and continues printing.
|
||
cBinderAttentionOverride - The device ignores the
|
||
binder attention condition and continues printing.
|
||
Additional information:
|
||
See OUTBIN1-OVERRIDE-MODE."
|
||
::= { outbin2 9 }
|
||
|
||
|
||
outbin3-override-mode OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or sets the device behavior when this output bin
|
||
condition causes printing to stop.
|
||
cCancelJob - The device cancels the job.
|
||
cOutbinFullOverride - The device sends subsequent
|
||
media to the overflow bin.
|
||
cOutbinAttentionOverride - The device ignores the
|
||
attention condition and continues printing.
|
||
cBinderAttentionOverride - The device ignores the
|
||
binder attention condition and continues printing.
|
||
Additional information:
|
||
See OUTBIN1-OVERRIDE-MODE."
|
||
::= { outbin3 9 }
|
||
|
||
|
||
outbin3-phd OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Provides the number of the Paper Handling Device that
|
||
contains this output bin."
|
||
::= { outbin3 11 }
|
||
|
||
|
||
outbin4-override-mode OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or sets the device behavior when this output bin
|
||
condition causes printing to stop.
|
||
cCancelJob - The device cancels the job.
|
||
cOutbinFullOverride - The device sends subsequent
|
||
media to the overflow bin.
|
||
cOutbinAttentionOverride - The device ignores the
|
||
attention condition and continues printing.
|
||
cBinderAttentionOverride - The device ignores the
|
||
binder attention condition and continues printing.
|
||
Additional information:
|
||
See OUTBIN1-OVERRIDE-MODE."
|
||
::= { outbin4 9 }
|
||
|
||
|
||
outbin4-phd OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Provides the number of the Paper Handling Device that
|
||
contains this output bin."
|
||
::= { outbin4 11 }
|
||
|
||
|
||
outbin5-override-mode OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or sets the device behavior when this output bin
|
||
condition causes printing to stop.
|
||
cCancelJob - The device cancels the job.
|
||
cOutbinFullOverride - The device sends subsequent
|
||
media to the overflow bin.
|
||
cOutbinAttentionOverride - The device ignores the
|
||
attention condition and continues printing.
|
||
cBinderAttentionOverride - The device ignores the
|
||
binder attention condition and continues printing.
|
||
Additional information:
|
||
See OUTBIN1-OVERRIDE-MODE."
|
||
::= { outbin5 9 }
|
||
|
||
|
||
outbin5-phd OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Provides the number of the Paper Handling Device that
|
||
contains this output bin."
|
||
::= { outbin5 11 }
|
||
|
||
|
||
outbin6-override-mode OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or sets the device behavior when this output bin
|
||
condition causes printing to stop.
|
||
cCancelJob - The device cancels the job.
|
||
cOutbinFullOverride - The device sends subsequent
|
||
media to the overflow bin.
|
||
cOutbinAttentionOverride - The device ignores the
|
||
attention condition and continues printing.
|
||
cBinderAttentionOverride - The device ignores the
|
||
binder attention condition and continues printing.
|
||
Additional information:
|
||
See OUTBIN1-OVERRIDE-MODE."
|
||
::= { outbin6 9 }
|
||
|
||
|
||
outbin6-phd OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Provides the number of the Paper Handling Device that
|
||
contains this output bin."
|
||
::= { outbin6 11 }
|
||
|
||
|
||
outbin7-override-mode OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or sets the device behavior when this output bin
|
||
condition causes printing to stop.
|
||
cCancelJob - The device cancels the job.
|
||
cOutbinFullOverride - The device sends subsequent
|
||
media to the overflow bin.
|
||
cOutbinAttentionOverride - The device ignores the
|
||
attention condition and continues printing.
|
||
cBinderAttentionOverride - The device ignores the
|
||
binder attention condition and continues printing.
|
||
Additional information:
|
||
See OUTBIN1-OVERRIDE-MODE."
|
||
::= { outbin7 9 }
|
||
|
||
|
||
outbin7-phd OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Provides the number of the Paper Handling Device that
|
||
contains this output bin."
|
||
::= { outbin7 11 }
|
||
|
||
|
||
outbin8-override-mode OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or sets the device behavior when this output bin
|
||
condition causes printing to stop.
|
||
cCancelJob - The device cancels the job.
|
||
cOutbinFullOverride - The device sends subsequent
|
||
media to the overflow bin.
|
||
cOutbinAttentionOverride - The device ignores the
|
||
attention condition and continues printing.
|
||
cBinderAttentionOverride - The device ignores the
|
||
binder attention condition and continues printing.
|
||
Additional information:
|
||
See OUTBIN1-OVERRIDE-MODE."
|
||
::= { outbin8 9 }
|
||
|
||
|
||
outbin8-phd OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Provides the number of the Paper Handling Device that
|
||
contains this output bin."
|
||
::= { outbin8 11 }
|
||
|
||
|
||
outbin9-override-mode OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or sets the device behavior when this output bin
|
||
condition causes printing to stop.
|
||
cCancelJob - The device cancels the job.
|
||
cOutbinFullOverride - The device sends subsequent
|
||
media to the overflow bin.
|
||
cOutbinAttentionOverride - The device ignores the
|
||
attention condition and continues printing.
|
||
cBinderAttentionOverride - The device ignores the
|
||
binder attention condition and continues printing.
|
||
Additional information:
|
||
See OUTBIN1-OVERRIDE-MODE."
|
||
::= { outbin9 9 }
|
||
|
||
|
||
outbin9-phd OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Provides the number of the Paper Handling Device that
|
||
contains this output bin."
|
||
::= { outbin9 11 }
|
||
|
||
|
||
outbin10-override-mode OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or sets the device behavior when this output bin
|
||
condition causes printing to stop.
|
||
cCancelJob - The device cancels the job.
|
||
cOutbinFullOverride - The device sends subsequent
|
||
media to the overflow bin.
|
||
cOutbinAttentionOverride - The device ignores the
|
||
attention condition and continues printing.
|
||
cBinderAttentionOverride - The device ignores the
|
||
binder attention condition and continues printing.
|
||
Additional information:
|
||
See OUTBIN1-OVERRIDE-MODE."
|
||
::= { outbin10 9 }
|
||
|
||
|
||
outbin10-phd OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Provides the number of the Paper Handling Device that
|
||
contains this output bin."
|
||
::= { outbin10 11 }
|
||
|
||
|
||
outbin11-override-mode OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or sets the device behavior when this output bin
|
||
condition causes printing to stop.
|
||
cCancelJob - The device cancels the job.
|
||
cOutbinFullOverride - The device sends subsequent
|
||
media to the overflow bin.
|
||
cOutbinAttentionOverride - The device ignores the
|
||
attention condition and continues printing.
|
||
cBinderAttentionOverride - The device ignores the
|
||
binder attention condition and continues printing.
|
||
Additional information:
|
||
See OUTBIN1-OVERRIDE-MODE."
|
||
::= { outbin11 9 }
|
||
|
||
|
||
outbin11-phd OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Provides the number of the Paper Handling Device that
|
||
contains this output bin."
|
||
::= { outbin11 11 }
|
||
|
||
|
||
low-marking-agent-processing OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eStop(1),
|
||
eCont(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or changes how the device processes a low
|
||
marking agent event. If eCont, then the device
|
||
continues to print. If eStop, then the device stops
|
||
until a continue event occurs."
|
||
::= { settings-marking-agent 3 }
|
||
|
||
|
||
default-ret OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eOff(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or changes the Resolution Enhancement Technology
|
||
setting. Devices that only support eOff and on should
|
||
map all other values to on and always return the same
|
||
non-eOff value to indicate on. The list of supported
|
||
values should be documented in the device POS.
|
||
Additional information:
|
||
Color LaserJet8550 doesn't have RET."
|
||
::= { imaging 5 }
|
||
|
||
|
||
default-print-quality OBJECT-TYPE
|
||
SYNTAX INTEGER(100..100)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or sets the default print quality. A value of
|
||
zero has the lowest print quality. A value of 100 has
|
||
the highest print quality. Each POS should document
|
||
what values in the 0 to 100 range are supported.
|
||
Additional information:
|
||
In Color LaserJet8550, the supported value is 100.
|
||
A value of 100 corresponds to ECONOMODE=OFF."
|
||
::= { imaging 7 }
|
||
|
||
|
||
phd2-device-specific-command OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object is used to send device-specific data to the
|
||
paper handling device. The meaning of the device-
|
||
specific command is dependent on the paper handling
|
||
device and must be specified in the POS.
|
||
If the paper handling device does not accept the
|
||
command, then an <badValue> will
|
||
be returned. If the device accepts the command, it may
|
||
still be processing the command after the response has
|
||
been returned. Depending on the device, the application
|
||
may need to query PHDx-DEVICE-MEMORY to see when the
|
||
command has completed.
|
||
Additional information:
|
||
If at least one (1) external paper handling device is
|
||
attached to the printer, then this object will exist.
|
||
Not applicable if the value of PHD2-TYPE is eEmpty.
|
||
Since it will usually take longer to send this command
|
||
to the device than PML allows for <set> operations, this
|
||
object will have a return value that does not necessarily
|
||
match the value currently received by the first device."
|
||
::= { ph2 2 }
|
||
|
||
|
||
phd2-device-memory OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object is used to read the current values stored in
|
||
shared memory available from the paper handling device.
|
||
Additional information:
|
||
If at least one external paper handling devices are attached
|
||
to the printer, then this object will exist.
|
||
Not applicable if the value of PHD2-TYPE is eEmpty.
|
||
This object returns the current memory stored in the
|
||
printer's NVRAM (non-volatile RAM) for the first paper
|
||
handling device. Currently, the printer allocates 16 bytes
|
||
for each device."
|
||
::= { ph2 4 }
|
||
|
||
|
||
phd3-device-specific-command OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object is used to send device-specific data to the
|
||
paper handling device. The meaning of the device-
|
||
specific command is dependent on the paper handling
|
||
device and must be specified in the POS.
|
||
If the paper handling device does not accept the
|
||
command, then an <badValue> will
|
||
be returned. If the device accepts the command, it may
|
||
still be processing the command after the response has
|
||
been returned. Depending on the device, the application
|
||
may need to query PHDx-DEVICE-MEMORY to see when the
|
||
command has completed.
|
||
Additional information:
|
||
If at least two (2) external paper handling
|
||
devices are attached to the printer, then this object
|
||
will exist. Not applicable if the value of PHD3-TYPE
|
||
is eEmpty.
|
||
Since it will usually take longer to send this
|
||
command to the device than PML allows for <Set>
|
||
operations, this object will have a return value
|
||
that does not necessarily match the value currently
|
||
received by the second device."
|
||
::= { ph3 2 }
|
||
|
||
|
||
phd3-device-memory OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object is used to read the current values stored in
|
||
shared memory available from the paper handling device.
|
||
Additional information:
|
||
If at least two external paper handling devices are attached
|
||
to the printer, then this object will exist.
|
||
Not applicable if the value of PHD3-TYPE is eEmpty.
|
||
This object returns the current memory stored in the
|
||
printer's NVRAM (non-volatile RAM) for the second paper
|
||
handling device. Currently, the printer allocates 16 bytes
|
||
for each device."
|
||
::= { ph3 4 }
|
||
|
||
|
||
media-names-available OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The value of this object controls which of the MEDIAx-
|
||
NAME objects are supported. If a bit is set to zero,
|
||
then attempting to get or set the corresponding MEDIAx-
|
||
NAME objects will return
|
||
<noSuchName>.
|
||
Additional information:
|
||
Setting a bit to one will cause the corresponding
|
||
MEDIAn- objects to be available (attempting to access an
|
||
unavailable object will return <noSuchName>).
|
||
MEDIA1- objects are always present in Color LaserJet8550, as this is the
|
||
default media. If this object is set to a value that does not
|
||
include cMediaName1Available, that bit will be set and a
|
||
status of <noError> will be returned."
|
||
::= { settings-print-media 1 }
|
||
|
||
|
||
media1-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 1 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media1 1 }
|
||
|
||
|
||
media1-short-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Length restricted version of the media name 1. The
|
||
length restriction is required to allow the media name
|
||
to be displayed on the device's control panel. The
|
||
device POS must state the maximum number of characters
|
||
allowed. If the device also has a limitation on what
|
||
characters in a character set can be used (e.g. only
|
||
uppercase characters allowed), the POS should also state
|
||
character restrictions.
|
||
Additional information:
|
||
The Maximum supported string length is
|
||
9 characters. If the user entered string is too long,
|
||
the device will store the first 9 characters and will
|
||
return the <noError> status."
|
||
::= { media1 2 }
|
||
|
||
|
||
media1-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Number of sheets of media 1 that have been printed. The
|
||
device POS should state whether this value is lost
|
||
across a power cycle or kept in NVRAM.
|
||
Additional information:
|
||
In Color LaserJet8550 the media page count saved in NVRAM
|
||
after every 10 pages. The maximum value is
|
||
4,294,967,295 which will never be reached in normal
|
||
operation.
|
||
The page count is incremented when a sheet of media is
|
||
pulled from an input tray. A duplex printed sheet will
|
||
cause this counter to be incremented by one."
|
||
::= { media1 3 }
|
||
|
||
|
||
media2-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 2 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media2 1 }
|
||
|
||
|
||
media2-short-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Length restricted version of the media name 2. See
|
||
MEDIA1-SHORT-NAME for details."
|
||
::= { media2 2 }
|
||
|
||
|
||
media2-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Number of sheets of media 2 that have been printed. See
|
||
MEDIA1-PAGE-COUNT for details.
|
||
Additional information:
|
||
See MEDIA1-PAGE-COUNT."
|
||
::= { media2 3 }
|
||
|
||
|
||
media3-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 3 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media3 1 }
|
||
|
||
|
||
media3-short-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Length restricted version of the media name 3. See
|
||
MEDIA1-SHORT-NAME for details."
|
||
::= { media3 2 }
|
||
|
||
|
||
media3-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Number of sheets of media 3 that have been printed. See
|
||
MEDIA1-PAGE-COUNT for details.
|
||
Additional information:
|
||
See MEDIA1-PAGE-COUNT."
|
||
::= { media3 3 }
|
||
|
||
|
||
media4-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 4 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media4 1 }
|
||
|
||
|
||
media4-short-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Length restricted version of the media name 4. See
|
||
MEDIA1-SHORT-NAME for details."
|
||
::= { media4 2 }
|
||
|
||
|
||
media4-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Number of sheets of media 4 that have been printed. See
|
||
MEDIA1-PAGE-COUNT for details.
|
||
Additional information:
|
||
See MEDIA1-PAGE-COUNT."
|
||
::= { media4 3 }
|
||
|
||
|
||
media5-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 5 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media5 1 }
|
||
|
||
|
||
media5-short-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Length restricted version of the media name 5. See
|
||
MEDIA1-SHORT-NAME for details."
|
||
::= { media5 2 }
|
||
|
||
|
||
media5-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Number of sheets of media 5 that have been printed. See
|
||
MEDIA1-PAGE-COUNT for details.
|
||
Additional information:
|
||
See MEDIA1-PAGE-COUNT."
|
||
::= { media5 3 }
|
||
|
||
|
||
media6-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 6 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media6 1 }
|
||
|
||
|
||
media6-short-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Length restricted version of the media name 6. See
|
||
MEDIA1-SHORT-NAME for details."
|
||
::= { media6 2 }
|
||
|
||
|
||
media6-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Number of sheets of media 6 that have been printed. See
|
||
MEDIA1-PAGE-COUNT for details.
|
||
Additional information:
|
||
See MEDIA1-PAGE-COUNT."
|
||
::= { media6 3 }
|
||
|
||
|
||
media7-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 7 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media7 1 }
|
||
|
||
|
||
media7-short-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Length restricted version of the media name 7. See
|
||
MEDIA1-SHORT-NAME for details."
|
||
::= { media7 2 }
|
||
|
||
|
||
media7-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Number of sheets of media 7 that have been printed. See
|
||
MEDIA1-PAGE-COUNT for details.
|
||
Additional information:
|
||
See MEDIA1-PAGE-COUNT."
|
||
::= { media7 3 }
|
||
|
||
|
||
media8-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 8 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media8 1 }
|
||
|
||
|
||
media8-short-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Length restricted version of the media name 8. See
|
||
MEDIA1-SHORT-NAME for details."
|
||
::= { media8 2 }
|
||
|
||
|
||
media8-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Number of sheets of media 8 that have been printed. See
|
||
MEDIA1-PAGE-COUNT for details.
|
||
Additional information:
|
||
See MEDIA1-PAGE-COUNT."
|
||
::= { media8 3 }
|
||
|
||
|
||
media9-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 9 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media9 1 }
|
||
|
||
|
||
media9-short-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Length restricted version of the media name 9. See
|
||
MEDIA1-SHORT-NAME for details."
|
||
::= { media9 2 }
|
||
|
||
|
||
media9-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Number of sheets of media 9 that have been printed. See
|
||
MEDIA1-PAGE-COUNT for details.
|
||
Additional information:
|
||
See MEDIA1-PAGE-COUNT."
|
||
::= { media9 3 }
|
||
|
||
|
||
media10-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 10 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media10 1 }
|
||
|
||
|
||
media10-short-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Length restricted version of the media name 10. See
|
||
MEDIA1-SHORT-NAME for details."
|
||
::= { media10 2 }
|
||
|
||
|
||
media10-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Number of sheets of media 10 that have been printed.
|
||
See MEDIA1-PAGE-COUNT for details.
|
||
Additional information:
|
||
See MEDIA1-PAGE-COUNT."
|
||
::= { media10 3 }
|
||
|
||
|
||
media11-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 11 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media11 1 }
|
||
|
||
|
||
media11-short-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Length restricted version of the media name 11. See
|
||
MEDIA1-SHORT-NAME for details."
|
||
::= { media11 2 }
|
||
|
||
|
||
media11-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Number of sheets of media 11 that have been printed.
|
||
See MEDIA1-PAGE-COUNT for details.
|
||
Additional information:
|
||
See MEDIA1-PAGE-COUNT."
|
||
::= { media11 3 }
|
||
|
||
|
||
media12-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 12 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media12 1 }
|
||
|
||
|
||
media12-short-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Length restricted version of the media name 12. See
|
||
MEDIA1-SHORT-NAME for details."
|
||
::= { media12 2 }
|
||
|
||
|
||
media12-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Number of sheets of media 12 that have been printed.
|
||
See MEDIA1-PAGE-COUNT for details.
|
||
Additional information:
|
||
See MEDIA1-PAGE-COUNT."
|
||
::= { media12 3 }
|
||
|
||
|
||
media13-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 13 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media13 1 }
|
||
|
||
|
||
media13-short-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Length restricted version of the media name 13. See
|
||
MEDIA1-SHORT-NAME for details.
|
||
Additional information:
|
||
See MEDIA1-SHORT-NAME."
|
||
::= { media13 2 }
|
||
|
||
|
||
media13-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Number of sheets of media 13 that have been printed.
|
||
See MEDIA1-PAGE-COUNT for details.
|
||
Additional information:
|
||
See MEDIA1-PAGE-COUNT."
|
||
::= { media13 3 }
|
||
|
||
|
||
media14-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 14 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media14 1 }
|
||
|
||
|
||
media14-short-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Length restricted version of the media name 14. See
|
||
MEDIA1-SHORT-NAME for details.
|
||
Additional information:
|
||
See MEDIA1-SHORT-NAME."
|
||
::= { media14 2 }
|
||
|
||
|
||
media14-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Number of sheets of media 14 that have been printed.
|
||
See MEDIA1-PAGE-COUNT for details.
|
||
Additional information:
|
||
See MEDIA1-PAGE-COUNT."
|
||
::= { media14 3 }
|
||
|
||
|
||
media15-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 15 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media15 1 }
|
||
|
||
|
||
media15-short-name OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Length restricted version of the media name 15. See
|
||
MEDIA1-SHORT-NAME for details.
|
||
Additional information:
|
||
See MEDIA1-SHORT-NAME."
|
||
::= { media15 2 }
|
||
|
||
|
||
media15-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Number of sheets of media 15 that have been printed.
|
||
See MEDIA1-PAGE-COUNT for details.
|
||
Additional information:
|
||
See MEDIA1-PAGE-COUNT."
|
||
::= { media15 3 }
|
||
|
||
|
||
channel-bytes-sent OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The low order 31 bits of the number of bytes sent from
|
||
the printer to the host on this logical channel."
|
||
::= { channel-entry 2 }
|
||
|
||
|
||
channel-bytes-received OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The low order 31 bits of the number of bytes received by
|
||
the printer from the host on this logical channel."
|
||
::= { channel-entry 3 }
|
||
|
||
|
||
channel-io-errors OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The low order 31 bits of the number of I/O errors which
|
||
have occured on this logical channel."
|
||
::= { channel-entry 4 }
|
||
|
||
|
||
channel-jobs-received OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The low order 31 bits of the number of print jobs which
|
||
have been received on this logical channel."
|
||
::= { channel-entry 5 }
|
||
|
||
|
||
channel-mio OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The number of the MIO card associated with this logical
|
||
channel. If this logical channel is not associated with
|
||
an MIO card a zero is returned. The value returned for
|
||
each logical channel is the MIO card's physical slot
|
||
number. The list of supported values should be
|
||
documented in the device POS.
|
||
Additional information:
|
||
The value returned will be zero for channel one.
|
||
If an MIOA card is installed, channels 3..18 will
|
||
return a value of one or two and,
|
||
if an MIOB card is installed, 19-34 will return a
|
||
value of one or two, but not the same as channels
|
||
3..18. When two MIO cards are installed, the value
|
||
returned by any channel 3..34 may change after the
|
||
printer is power cycled."
|
||
::= { channel-entry 6 }
|
||
|
||
|
||
mass-storage-resource-change-counter OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A counter which changes when a mass storage based
|
||
resource has been added or deleted.
|
||
Additional information:
|
||
The value of this counter changes
|
||
each time the MASS-STORAGE-RESOURCE-CHANGED object
|
||
is set to eTrue. The value also changes when the
|
||
mass storage device is initialized. However, the value does not
|
||
change when a mass storage device is removed and a different
|
||
mass storage device is installed. Performing a cold reset sets
|
||
this object back to the factory default value.
|
||
Returns <noSuchName>
|
||
status if attempting to access this object and there
|
||
is no storage device is installed."
|
||
::= { mass-storage-resources 1 }
|
||
|
||
|
||
mass-storage-resource-changed OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eTrue(2)
|
||
}
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Setting to eTrue causes MASS-STORAGE-RESOURCE-CHANGE-
|
||
COUNTER to be incremented.
|
||
Additional information:
|
||
Returns <noSuchName>
|
||
status if attempting to access this object and there
|
||
is no storage device is installed."
|
||
::= { mass-storage-resources 2 }
|
||
|
||
|
||
hrdiskstorageaccess OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eHreadWrite(1),
|
||
eHreadOnly(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"An indication if this long-term storage device is
|
||
readable and writable or only readable. This
|
||
should reflect the media type, any write-protect
|
||
mechanism, and any device configuration that
|
||
affects the entire device.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
This object can be set to write protect
|
||
the mass storage device, even though the host resources MIB
|
||
documents the object as read-only.
|
||
Returns <noSuchName> status if attempting
|
||
to perform a Get on this OID with no mass storage device
|
||
installed."
|
||
::= { hrDiskStorageEntry 1 }
|
||
|
||
|
||
hrdiskstoragemedia OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eHother(1),
|
||
eHhardDisk(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"An indication of the type of media used in this
|
||
long-term storage device.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
Constant. Returns <noSuchName>
|
||
status if attempting to perform a Get on this OID with no
|
||
mass storage device installed."
|
||
::= { hrDiskStorageEntry 2 }
|
||
|
||
|
||
hrdiskstorageremoveble OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eHfalse(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Denotes whether or not the disk media may be
|
||
removed from the drive.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
Constant. Returns
|
||
<noSuchName> status if attempting
|
||
to perform a Get on this OID with no mass storage device
|
||
installed."
|
||
::= { hrDiskStorageEntry 3 }
|
||
|
||
|
||
hrdiskstoragecapacity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total size for this long-term storage device.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
The capacity is in Kbytes. Returns
|
||
<noSuchName> status if attempting
|
||
to perform a Get on this OID with no mass storage device
|
||
installed."
|
||
::= { hrDiskStorageEntry 4 }
|
||
|
||
|
||
hrpartitionindex OBJECT-TYPE
|
||
SYNTAX INTEGER(1..2147483647)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A unique value for each partition on this long-
|
||
term storage device. The value for each long-term
|
||
storage device must remain constant at least from
|
||
one re-initialization of the agent to the next re-
|
||
initialization.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
Constant. The first and second index
|
||
indicates the hrDeviceIndex for this mass storage device.
|
||
The value of this object is the same as
|
||
the second index. The printer only supports one
|
||
partition per mass storage device. Returns
|
||
<noSuchName> status if attempting
|
||
to perform a Get on this OID with no mass storage device
|
||
installed."
|
||
::= { hrPartitionEntry 1 }
|
||
|
||
|
||
hrpartitionlabel OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..128))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A textual description of this partition.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
The MS-DOS volume label. The volume
|
||
label is not writable. Returns <noSuchName>
|
||
status if attempting to perform a Get on this OID with no mass
|
||
storage device installed.
|
||
This object is not settable and returns the empty
|
||
string if the mass storage device has not been initialized."
|
||
::= { hrPartitionEntry 2 }
|
||
|
||
|
||
hrpartitionid OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A descriptor which uniquely represents this
|
||
partition to the responsible operating system. On
|
||
some systems, this might take on a binary
|
||
representation.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
Constant. The value returned is the
|
||
ASCII string version of the hrDeviceIndex for
|
||
this mass storage device. Returns <noSuchName>
|
||
status if attempting to perform a Get on this OID with no mass
|
||
storage device installed."
|
||
::= { hrPartitionEntry 3 }
|
||
|
||
|
||
hrpartitionsize OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The size of this partition.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
The capacity is in Kbytes. Returns the
|
||
same value as hrDiskStorageCapacity. Returns
|
||
<noSuchName> status if attempting
|
||
to perform a Get on this OID with no mass storage device
|
||
installed."
|
||
::= { hrPartitionEntry 4 }
|
||
|
||
|
||
hrpartitionfsindex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..2147483647)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The index of the file system mounted on this
|
||
partition. If no file system is mounted on this
|
||
partition, then this value shall be zero. Note
|
||
that multiple partitions may point to one file
|
||
system, denoting that that file system resides on
|
||
those partitions. Multiple file systems may not
|
||
reside on one partition.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
Indicates if the mass storage device has been
|
||
initialized. Returns zero if the mass storage device is not
|
||
initialized, otherwise the value matches the
|
||
hrDeviceIndex value for this mass storage device.
|
||
The value indicates the hrFileSystemTable index for the
|
||
file system stored on this partition. Returns
|
||
<noSuchName> status if attempting
|
||
to perform a Get on this OID with no mass storage device
|
||
installed."
|
||
::= { hrPartitionEntry 5 }
|
||
|
||
|
||
hrfsindex OBJECT-TYPE
|
||
SYNTAX INTEGER(1..2147483647)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A unique value for each file system local to this
|
||
host. The value for each file system must remain
|
||
constant at least from one re-initialization of
|
||
the agent to the next re-initialization.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
Constant. The index is assigned by the
|
||
person controlling the printer object definition.
|
||
Returns <noSuchName> status if
|
||
attempting to perform a Get on this OID with no mass storage device
|
||
installed or if the file system has not been initialized."
|
||
::= { hrFSEntry 1 }
|
||
|
||
|
||
hrfsmountpoint OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The path name of the root of this file system.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
Constant. Returns <noSuchName>
|
||
status if attempting to perform a Get on this OID with no mass
|
||
storage device installed or if the file system has not been
|
||
initialized."
|
||
::= { hrFSEntry 2 }
|
||
|
||
|
||
hrfsremotemountpoint OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A description of the name and/or address of the
|
||
server that this file system is mounted from.
|
||
This may also include parameters such as the mount
|
||
point on the remote file system. If this is not a
|
||
remote file system, this string should have a
|
||
length of zero.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
Constant. This printer does not support
|
||
remote file system mounting. Returns
|
||
<noSuchName> status if attempting
|
||
to perform a Get on this OID with no mass storage device installed
|
||
or if the file system has not been initialized."
|
||
::= { hrFSEntry 3 }
|
||
|
||
|
||
hrfstype OBJECT-TYPE
|
||
SYNTAX OBJECT IDENTIFIER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The value of this object identifies the type of
|
||
this file system.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
Constant. Returns <noSuchName>
|
||
status if attempting to perform a Get on this OID with no mass
|
||
storage device installed or if the file system has not been
|
||
initialized."
|
||
::= { hrFSEntry 4 }
|
||
|
||
|
||
hrfsaccess OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eHreadWrite(1),
|
||
eHreadOnly(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"An indication if this file system is logically
|
||
configured by the operating system to be readable
|
||
and writable or only readable. This does not
|
||
represent any local access-control policy, except
|
||
one that is applied to the file system as a whole.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
Returns the same value as hrDiskStorageAccess.
|
||
Returns <noSuchName> status if attempting
|
||
to perform a Get on this OID with no mass storage device installed
|
||
or if the file system has not been initialized."
|
||
::= { hrFSEntry 5 }
|
||
|
||
|
||
hrfsbootable OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eHfalse(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A flag indicating whether this file system is
|
||
bootable.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
Constant. Returns <noSuchName>
|
||
status if attempting to perform a Get on this OID with no mass
|
||
storage device installed or if the file system has not been
|
||
initialized."
|
||
::= { hrFSEntry 6 }
|
||
|
||
|
||
hrfsstorageindex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..2147483647)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The index of the hrStorageEntry that represents
|
||
information about this file system. If there is
|
||
no such information available, then this value
|
||
shall be zero. The relevant storage entry will be
|
||
useful in tracking the percent usage of this file
|
||
system and diagnosing errors that may occur when
|
||
it runs out of space.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
Constant. The value indicates the
|
||
hrStorageTable index for this mass storage device. Returns
|
||
<noSuchName> status if attempting
|
||
to perform a Get on this OID with no mass storage device installed
|
||
or if the file system has not been initialized."
|
||
::= { hrFSEntry 7 }
|
||
|
||
|
||
hrfslastfullbackupdate OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The last date at which this complete file system
|
||
was copied to another storage device for backup.
|
||
This information is useful for ensuring that
|
||
backups are being performed regularly.
|
||
If this information is not known, then this
|
||
variable shall have the value corresponding to
|
||
January 1, year 0000, 00:00:00.0, which is encoded
|
||
as (hex)'00 00 01 01 00 00 00 00'.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
Constant. The default value is the value defined
|
||
to represent an unknown time of January 1, year 0000,
|
||
00:00:00.0. Returns <noSuchName>
|
||
status if attempting to perform a Get on this OID with no mass
|
||
storage device installed or if the file system has not
|
||
been initialized."
|
||
::= { hrFSEntry 8 }
|
||
|
||
|
||
hrfslastpartialbackupdate OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The last date at which a portion of this file
|
||
system was copied to another storage device for
|
||
backup. This information is useful for ensuring
|
||
that backups are being performed regularly.
|
||
If this information is not known, then this
|
||
variable shall have the value corresponding to
|
||
January 1, year 0000, 00:00:00.0, which is encoded
|
||
as (hex)'00 00 01 01 00 00 00 00'.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
Constant. The default value is the value defined
|
||
to represent an unknown time of January 1, year 0000,
|
||
00:00:00.0. Returns <noSuchName> status if
|
||
attempting to perform a Get on this OID with no mass storage
|
||
device installed or if the file system has not been initialized."
|
||
::= { hrFSEntry 9 }
|
||
|
||
|
||
hrmemorysize OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The amount of physical main memory contained by
|
||
the host.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
The unit of measure for this object is 1024 bytes.
|
||
The default value assumes the base printer with no
|
||
additional memory."
|
||
::= { hrStorage 2 }
|
||
|
||
|
||
hrstorageindex OBJECT-TYPE
|
||
SYNTAX INTEGER(1..2147483647)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A unique value for each logical storage area
|
||
contained by the host.
|
||
Refer to RFC 1514, Host Resources MIB, for more details."
|
||
::= { hrStorageEntry 1 }
|
||
|
||
|
||
hrstoragetype OBJECT-TYPE
|
||
SYNTAX OBJECT IDENTIFIER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The type of storage represented by this entry.
|
||
Refer to RFC 1514, Host Resources MIB, for more details."
|
||
::= { hrStorageEntry 2 }
|
||
|
||
|
||
hrstoragedescr OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A description of the type and instance of the
|
||
storage described by this entry.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
This object is not localized."
|
||
::= { hrStorageEntry 3 }
|
||
|
||
|
||
hrstorageallocationunits OBJECT-TYPE
|
||
SYNTAX INTEGER(1..2147483647)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The size, in bytes, of the data objects allocated
|
||
from this pool. If this entry is monitoring
|
||
sectors, blocks, buffers, or packets, for example,
|
||
this number will commonly be greater than one.
|
||
Otherwise this number will typically be one.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
Unit is one byte.
|
||
The size, in bytes, of the data objects allocated from
|
||
this pool. If this entry is monitoring sectors, blocks,
|
||
buffers, or packets, for example, this number will commonly
|
||
be greater than one. Otherwise this number will typically
|
||
be one."
|
||
::= { hrStorageEntry 4 }
|
||
|
||
|
||
hrstoragesize OBJECT-TYPE
|
||
SYNTAX INTEGER(0..2147483647)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The size of the storage represented by this entry,
|
||
in units of hrStorageAllocationUnits.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
Total formatter RAM. Color LaserJet8550 has 0 byte of memory
|
||
soldered on the formatter."
|
||
::= { hrStorageEntry 5 }
|
||
|
||
|
||
hrstorageused OBJECT-TYPE
|
||
SYNTAX INTEGER(0..2147483647)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The amount of the storage represented by this
|
||
entry that is allocated, in units of
|
||
hrStorageAllocationUnits.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
This object returns the amount of memory in use
|
||
by the printer at the current time. This object should
|
||
not be used when creating a print job for the device
|
||
because the amount of memory in use will likely be different
|
||
when the printer processes the print job."
|
||
::= { hrStorageEntry 6 }
|
||
|
||
|
||
hrstorageallocationfailures OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The number of requests for storage represented by
|
||
this entry that could not be honored due to not
|
||
enough storage. It should be noted that as this
|
||
object has a SYNTAX of Counter, that it does not
|
||
have a defined initial value. However, it is
|
||
recommended that this object be initialized to
|
||
zero.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
This object is set to zero at power on and when any
|
||
reset is done via prtGeneralReset.
|
||
This object is incremented whenever the printer is
|
||
short on memory or out of memory/job cleared."
|
||
::= { hrStorageEntry 7 }
|
||
|
||
|
||
hrdeviceindex OBJECT-TYPE
|
||
SYNTAX INTEGER(1..2147483647)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A unique value for each device contained by the
|
||
host. The value for each device must remain
|
||
constant at least from one re-initialization of the
|
||
agent to the next re-initialization.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
The entry in the Device Table which
|
||
describes the printer. "
|
||
::= { hrDeviceEntry 1 }
|
||
|
||
|
||
hrdevicetype OBJECT-TYPE
|
||
SYNTAX OBJECT IDENTIFIER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"An indication of the type of device.
|
||
If this value is `hrDeviceProcessor { hrDeviceTypes
|
||
3 }' then an entry exists in the hrProcessorTable
|
||
which corresponds to this device.
|
||
If this value is `hrDeviceNetwork { hrDeviceTypes 4
|
||
}', then an entry exists in the hrNetworkTable
|
||
which corresponds to this device.
|
||
If this value is `hrDevicePrinter { hrDeviceTypes 5
|
||
}', then an entry exists in the hrPrinterTable
|
||
which corresponds to this device.
|
||
If this value is `hrDeviceDiskStorage {
|
||
hrDeviceTypes 6 }', then an entry exists in the
|
||
hrDiskStorageTable which corresponds to this
|
||
device.
|
||
Refer to RFC 1514, Host Resources MIB, for more details."
|
||
::= { hrDeviceEntry 2 }
|
||
|
||
|
||
hrdevicedescr OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A textual description of this device, including
|
||
the device's manufacturer and revision, and
|
||
optionally, its serial number.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
This object is not localized."
|
||
::= { hrDeviceEntry 3 }
|
||
|
||
|
||
hrdeviceid OBJECT-TYPE
|
||
SYNTAX OBJECT IDENTIFIER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The product ID for this device.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
The complete OID reported by this object is:
|
||
.1.3.6.1.4.1.11.2.3.9.1.2.10"
|
||
::= { hrDeviceEntry 4 }
|
||
|
||
|
||
hrdevicestatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eHrunning(2),
|
||
eHwarning(3),
|
||
eHdown(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The current operational state of the device
|
||
described by this row of the table. A value
|
||
unknown(1) indicates that the current state of the
|
||
device is unknown. running(2) indicates that the
|
||
device is up and running and that no unusual error
|
||
conditions are known. The warning(3) state
|
||
indicates that agent has been informed of an
|
||
unusual error condition by the operational software
|
||
(e.g., a disk device driver) but that the device is
|
||
still 'operational'. An example would be high
|
||
number of soft errors on a disk. A value of
|
||
testing(4), indicates that the device is not
|
||
available for use because it is in the testing
|
||
state. The state of down(5) is used only when the
|
||
agent has been informed that the device is not
|
||
available for any use.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
The printer's condition is mapped as follows:
|
||
eHrunning -- Printer ready to print or is printing.
|
||
May be in power save mode.
|
||
eHwarning -- A condition exists that needs attention but it is
|
||
not currently preventing printing. A non-critical alert is
|
||
active.
|
||
eHdown -- Printer is not printing due to an error condition.
|
||
A critical alert is active, human interaction is needed to
|
||
bring the printer to a ready state."
|
||
::= { hrDeviceEntry 5 }
|
||
|
||
|
||
hrdeviceerrors OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The number of errors detected on this device. It
|
||
should be noted that as this object has a SYNTAX
|
||
of Counter, that it does not have a defined
|
||
initial value. However, it is recommended that
|
||
this object be initialized to zero.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
This is the number of critical alerts that have been
|
||
entered into the alert table since the device was powered on.
|
||
The maximum value for this object is 2^32-1."
|
||
::= { hrDeviceEntry 6 }
|
||
|
||
|
||
hrprinterstatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eHother(1),
|
||
eHidle(3),
|
||
eHprinting(4),
|
||
eHwarmup(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The current status of this printer device. When
|
||
in the idle(1), printing(2), or warmup(3) state,
|
||
the corresponding hrDeviceStatus should be
|
||
running(2) or warning(3). When in the unknown
|
||
state, the corresponding hrDeviceStatus should be
|
||
unknown(1).
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
The printer's condition is mapped as follows:
|
||
eHother -- The printer is offline or a critical alert is
|
||
active.
|
||
eHidle -- The printer is not doing any of the items listed below
|
||
for eHprinting status.
|
||
eHprinting -- The printer is processing PJL or PDL data,
|
||
or processeing a control panel request, or printing images.
|
||
eHwarmup -- If hrDeviceStatus is eHdown, then the printer is
|
||
currently offline but is resolving the condition that caused
|
||
it be offline. It will be online when it is ready to print.
|
||
If hrDeviceStatus is eHrunning, then the printer was in power
|
||
save mode and is now becoming ready to print."
|
||
::= { hrPrinterEntry 1 }
|
||
|
||
|
||
hrprinterdetectederrorstate OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This object represents any error conditions
|
||
detected by the printer. The error conditions are
|
||
encoded as bits in an octet string, with the
|
||
following definitions:
|
||
Condition Bit # hrDeviceStatus
|
||
lowPaper 0 warning(3)
|
||
noPaper 1 down(5)
|
||
lowToner 2 warning(3)
|
||
noToner 3 down(5)
|
||
doorOpen 4 down(5)
|
||
jammed 5 down(5)
|
||
offline 6 down(5)
|
||
serviceRequested 7 warning(3)
|
||
If multiple conditions are currently detected and
|
||
the hrDeviceStatus would not otherwise be
|
||
unknown(1) or testing(4), the hrDeviceStatus shall
|
||
correspond to the worst state of those indicated,
|
||
where down(5) is worse than warning(3) which is
|
||
worse than running(2).
|
||
Bits are numbered starting with the most
|
||
significant bit of the first byte being bit 0, the
|
||
least significant bit of the first byte being bit
|
||
7, the most significant bit of the second byte
|
||
being bit 8, and so on. A one bit encodes that
|
||
the condition was detected, while a zero bit
|
||
encodes that the condition was not detected.
|
||
This object is useful for alerting an operator to
|
||
specific warning or error conditions that may
|
||
occur, especially those requiring human
|
||
intervention.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
Color LaserJet8550 reports error conditions as follows:
|
||
lowPaper -- A tray is empty, but the media to be loaded is not
|
||
currently needed.
|
||
hrDeviceStatus = eHwarning;
|
||
hrPrinterStatus = eHidle or eHprinting;
|
||
a non-critical alert is active.
|
||
noPaper -- A tray is empty and must be filled for printing to
|
||
continue.
|
||
hrDeviceStatus = eHdown;
|
||
hrPrinterStatus = eHother;
|
||
a non-critical alert is active.
|
||
lowToner -- Toner is almost gone. The quality of printed pages
|
||
will begin to deteriorate until the toner is completely gone.
|
||
hrDeviceStatus = eHwarning;
|
||
hrPrinterStatus = eHidle or eHprinting;
|
||
a non-critical alert is active.
|
||
noToner -- Toner Low 2 or no cartridge installed.
|
||
CoverOpen -- A Cover is open.
|
||
hrDeviceStatus = eHdown;
|
||
hrPrinterStatus = eHother;
|
||
a non-critical alert is active.
|
||
jammed -- A jam condition is preventing printing.
|
||
hrDeviceStatus = eHdown;
|
||
hrPrinterStatus = eHother;
|
||
a critical alert is active.
|
||
offline -- Printer is offline.
|
||
hrDeviceStatus = eHdown;
|
||
hrPrinterStatus = eHother;
|
||
a critical alert is active.
|
||
serviceRequested -- Any status or error condition not listed
|
||
above. If the condition prevents printing, the 'offline'
|
||
bit is also set and the hrDeviceStatus and hrPrinterStatus
|
||
listed for offline above are returned.
|
||
hrDeviceStatus = eHwarning;
|
||
hrPrinterStatus = eHidle or eHprinting;
|
||
a non-critical alert is active."
|
||
::= { hrPrinterEntry 2 }
|
||
|
||
|
||
channelnumberofchannels OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"An indication of how many print data channels the I/O
|
||
card supports.
|
||
Additional information:
|
||
This object is used by the MIO card to tell the peripheral
|
||
firmware how many logical channels will be used by the card.
|
||
This object can only be set once per physical channel. If
|
||
an attempt is made to set it a subsequent time it is ignored
|
||
and an return code of <genErr>
|
||
is returned.
|
||
If new firmware is dynamically downloaded to the IO card
|
||
card, and if that firmware uses more logical channels, it is
|
||
necessary to reset the printer."
|
||
::= { channel 1 }
|
||
|
||
|
||
channelprinteralert OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Identifies the values of prtAlertIndex,
|
||
prtAlertSeverityLevel, prtAlertGroup,
|
||
prtAlertGroupIndex, prtAlertLocation, and prtAlertCode
|
||
for the latest critical evnet in the prtAlertTable. The
|
||
binary string is defined as following:
|
||
------------------------------------------------------
|
||
Field | Filed | Description
|
||
Offset | Length |
|
||
------------------------------------------------------
|
||
0 | 4 | the value of prtAlertIndex
|
||
4 | 4 | the value of prtAlertSeverityLevel
|
||
8 | 4 | the value of prtAlertGroup
|
||
12 | 4 | the value of prtAlertGroupIndex
|
||
16 | 4 | the value of prtAlertLocation
|
||
20 | 4 | the value of prtAlertCode
|
||
------------------------------------------------------
|
||
Each field is in Big Endian style.
|
||
Additional information:
|
||
This object is used to pass alert information from the
|
||
peripheral to the MIO card. The standard printer MIB
|
||
contains the following description:
|
||
printerAlert TRAP-TYPE
|
||
ENTERPRISE printerV1Alert
|
||
VARIABLES { prtAlertIndex, prtAlertSeverityLevel, prtAlertGroup,
|
||
prtAlertGroupIndex, prtAlertLocation, prtAlertCode }
|
||
DESCRIPTION
|
||
'This trap is sent whenever a critical event is added to the
|
||
prtAlertTable.'
|
||
In order to provide this information in the trap packet, the
|
||
MIO card enables traps on channelPrinterAlert. When a critical
|
||
alert is generated the peripheral fills the appropriate value
|
||
into this object and sends it to the card.
|
||
This object is a structure which contains 24 bytes of data.
|
||
The structure is:
|
||
struct structAlertInfo {
|
||
sint32 prtAlertIndex;
|
||
sint32 prtAlertSeverityLevel;
|
||
sint32 prtAlertGroup;
|
||
sint32 prtAlertGroupIndex;
|
||
sint32 prtAlertLocation;
|
||
sint32 prtAlertCode;
|
||
} thisAlertData;"
|
||
::= { channel 2 }
|
||
|
||
|
||
channeltype OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eChOther(1),
|
||
eChAppleTalkPAP(7),
|
||
eChLPDServer(8),
|
||
eChNetwareRPrinter(9),
|
||
eChNetwarePServer(10),
|
||
eChPort9100(11),
|
||
eChDLCLLCPort(15),
|
||
eChBidirPortTCP(38)
|
||
}
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Identifies the type of MIO print data channel.
|
||
Additional information:
|
||
This object is for use by the I/O card only. After telling
|
||
the peripheral how many logical channels will be used,
|
||
the MIO card tells the printer the type of each of the
|
||
channels. The type information is passed using the channelType
|
||
object. Values are then saved by the peripheral and reported
|
||
when users request the value of prtChannelType."
|
||
::= { channelEntry 2 }
|
||
|
||
|
||
channelprotocolversion OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The version of the protocol used on this MIO print data
|
||
channel.
|
||
Additional information:
|
||
This object is for use by the I/O card only. After telling
|
||
the peripheral how many logical channels will be used,
|
||
the MIO card tells the printer the protocol version of each
|
||
of the channels. The protocol version information is passed
|
||
using the channelProtocolVersion object. Values are then saved
|
||
by the peripheral and reported when users request the value of
|
||
prtChannelProtocolVersion."
|
||
::= { channelEntry 3 }
|
||
|
||
|
||
channelstate OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eChOther(1),
|
||
eChPrintDataAccecped(3),
|
||
eChNoDataAccepted(4)
|
||
}
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The state of this print data channel. The value
|
||
determines whether control information and print data is
|
||
allowed through this channel or not.
|
||
Additional information:
|
||
This object is for use by the I/O card only. After telling the
|
||
peripheral how many logical channels will be used, the MIO
|
||
card tells the printer the state of each of the channels.
|
||
The state can change from time to time. The state information
|
||
is passed using the channelState object. Values are saved by
|
||
the peripheral and reported when users request the value of
|
||
prtChannelState."
|
||
::= { channelEntry 4 }
|
||
|
||
|
||
channelifindex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The value of ifIndex which corresponds to this channel.
|
||
Additional information:
|
||
This object is for use by the I/O card only. After telling
|
||
the peripheral how many logical channels will be used,
|
||
the MIO card tells the printer the value of the IfIndex
|
||
for each channel. The IfIndex is used as part of MIB-II.
|
||
The values are saved by the peripheral and reported when
|
||
users request the value of prtChannelIfIndex."
|
||
::= { channelEntry 5 }
|
||
|
||
|
||
channelstatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Sub-unit status is reported in the entries of the
|
||
principle table in the Group that represents the sub-
|
||
unit. For sub-units that report a status, there is a
|
||
status column in the table and the value of this column
|
||
is always an integer formed in the following way.
|
||
The SubUnitStatus is an integer that is the sum of 5
|
||
distinct values, Availability, Non-Critical, Critical,
|
||
On-line, and Transitioning. These values are:
|
||
Availability value
|
||
Available and Idle 0 000'b
|
||
Available and Standby 2 010'b
|
||
Available and Active 4 100'b
|
||
Available and Busy 6 110'b
|
||
Unavailable and OnRequest 1 001'b
|
||
Unavailable because Broken 3 011'b
|
||
Unknown 5 101'b
|
||
Non-Critical
|
||
No Non-Critical Alerts 0
|
||
Non-Critical Alerts 8
|
||
Critical
|
||
No Critical Alerts 0
|
||
Critical Alerts 16
|
||
On-Line
|
||
Intended state is On-Line 0
|
||
Intended state is Off-Line 32
|
||
Transitioning
|
||
At intended state 0
|
||
Transitioning to intended state 64
|
||
Additional information:
|
||
This object is for use by the I/O card only. After telling
|
||
the peripheral how many logical channels will be used,
|
||
the MIO card tells the printer the status of each of
|
||
the channels. The status can change from time to time.
|
||
The status information is passed using the channelStatus
|
||
object. Values are saved by the peripheral and reported
|
||
when users request the value of prtChannelStatus."
|
||
::= { channelEntry 6 }
|
||
|
||
|
||
pe-test-button-press OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eButton1Pressed(1),
|
||
eButton2Pressed(2),
|
||
eButton3Pressed(3),
|
||
eButton4Pressed(4),
|
||
eButton5Pressed(5),
|
||
eButton6Pressed(6),
|
||
eButton7Pressed(7),
|
||
eButton8Pressed(8),
|
||
eButton9Pressed(9),
|
||
eButton10Pressed(10)
|
||
}
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"OBSOLETE! Use CONTROL-PANEL-BUTTON-PRESS instead.
|
||
Writing this object simulates pressing a front panel
|
||
button. The mapping of a value to a device's front
|
||
panel button is device specific. For example, in the
|
||
LaserJet 5Si product, the mapping is:
|
||
eButton1Pressed - Online
|
||
eButton2Pressed - Menu
|
||
eButton3Pressed - Item
|
||
eButton4Pressed - Plus
|
||
eButton5Pressed - Select
|
||
This object should not be in the print engine test sub-
|
||
tree, but the implementing engineer made up an OID,
|
||
instead of getting one assigned. Please don't do that!"
|
||
::= { print-engine-test 6 }
|
||
|
||
|
||
prtgeneralconfigchanges OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Counts configuration changes that change the capabilities of
|
||
a printer, such as the addition/deletion of input/output bins,
|
||
the addition/deletion of interpreters, or changes in media
|
||
size. Such changes will often affect the capability of the
|
||
printer to service certain types of print jobs.
|
||
Management applications may cache infrequently changed
|
||
configuration information about sub-units on the printer.
|
||
This object should be incremented whenever the agent wishes
|
||
such applications to invalidate that cache and re-download
|
||
all of this configuration information, thereby signaling a
|
||
change in the printer's configuration.
|
||
|
||
For example, if an input tray that contained paper of
|
||
different dimensions was added, this counter would be
|
||
incremented.
|
||
As an additional example, this counter would not be
|
||
incremented when an input tray is removed or the level of an
|
||
input device changes.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
This is a 32 bit counter (unsigned). When it reaches
|
||
its maximum value, it will roll to zero."
|
||
::= { prtGeneralEntry 1 }
|
||
|
||
|
||
prtgeneralcurrentlocalization OBJECT-TYPE
|
||
SYNTAX INTEGER(1..11)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The value of the prtLocalizationIndex corresponding to the
|
||
current language, country, and character set to be used for
|
||
localized string values that are identified as being dependent
|
||
on the value of this object. Note that this object does not
|
||
apply to localized strings in the prtConsole group or to any
|
||
object that is not explicitly identified as being localized
|
||
according to prtGeneralCurrentLocalization.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML LOCALIZATION-LANGUAGE.
|
||
The value of this object is saved in NVRAM."
|
||
::= { prtGeneralEntry 2 }
|
||
|
||
|
||
prtgeneralreset OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePnotResetting(3),
|
||
ePpowerCycleReset(4),
|
||
ePresetToNVRAM(5),
|
||
ePresetToFactoryDefaults(6)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Setting this value to `powerCycleReset', `resetToNVRAM', or
|
||
`resetToFactoryDefaults' will result in the resetting of the
|
||
printer. When read, this object will always have the value
|
||
`notResetting(3)', and a SET of the value `notResetting' shall
|
||
have no effect on the printer. Some of the defined values are
|
||
optional. However, every implementation must support at least
|
||
the values `notResetting' and 'resetToNVRAM'.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML USER-NVRAM-RESET and POWER-ON-RESET.
|
||
All resets follow the same sequence of events except that a
|
||
a value of ePresetToFactoryDefaults first makes a call to
|
||
reset the NVRAM to factory defaults. Then, the following
|
||
sequence of events occur:
|
||
1. A delay is initiated while a reply is returned to the
|
||
requestor indicating OK.
|
||
2. The printer goes off-line.
|
||
3. The control panel is disabled.
|
||
4. The paper path is flushed.
|
||
5. The printer is reset per the request. The printer will
|
||
respond to PML requests up to this point in time.
|
||
Setting this object to ePpowerCycleReset causes Color LaserJet8550 to
|
||
perform its power on initialization routines. I/O cards are
|
||
reset (NVRAM on the cards is not changed; all I/O buffers are
|
||
flushed).
|
||
The tests normally run at power on time are executed.
|
||
Setting this object to ePresetToNVRAM causes the printer to
|
||
reset itself to its power on state without doing its normal
|
||
power on testing. The I/O cards are not reset and I/O buffers
|
||
remain intact.
|
||
Setting this object to ePresetToFactoryDefaults causes the
|
||
same action as a Cold Reset operation performed at the control
|
||
panel (except power on testing is not performed).
|
||
The I/O cards are not reset and I/O buffers remain intact."
|
||
::= { prtGeneralEntry 3 }
|
||
|
||
|
||
prtgeneralcurrentoperator OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..32))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The name of the person who is responsible for operating
|
||
this printer. It is suggested that this string include
|
||
information that would enable other humans to reach the operator,
|
||
such as a phone number. As a convention to facilitate automatic
|
||
notification of the operator by the agent or the network
|
||
management station, the phone number, fax number or email address
|
||
should be placed on a separate line starting with ASCII LF (hex
|
||
0x0A) and the ASCII text string (without the quotes): 'phone: ',
|
||
'fax: ', and 'email: ', respectively. Phone numbers may contain
|
||
digits, whitespace and parentheses, which shall be ignored. Phone
|
||
numbers may also include ASCII comma characters(hex 2C) that are
|
||
used to indicate a two-second pause during the dialing sequence.
|
||
If either the phone, fax, or email information is not available,
|
||
then a line should not be included for this information.
|
||
NOTE: For interoperability purposes, it is advisable to use email
|
||
addresses formatted according to RFC 822 requirements.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML SYSTEM-CONTACT.
|
||
The maximum
|
||
supported string length is 32 characters. If the user
|
||
entered string is too long, the device will store as
|
||
much as possible and will return the
|
||
<noError> status.
|
||
This object is saved in NVRAM."
|
||
::= { prtGeneralEntry 4 }
|
||
|
||
|
||
prtgeneralserviceperson OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..32))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The name of the person responsible for servicing this
|
||
printer. It is suggested that this string include information
|
||
that would enable other humans to reach the service person, such
|
||
as a phone number. As a convention to facilitate automatic
|
||
notification of the service person by the agent or a network
|
||
management station, the phone number, fax number or email address
|
||
should be placed on a separate line starting with ASCII LF (hex
|
||
0x0A) and the ASCII text string (without the quotes): 'phone: ',
|
||
'fax: ', and 'email: ', respectively. Phone numbers may contain
|
||
digits, whitespace and parentheses, which shall be ignored. Phone
|
||
numbers can also include one or more ASCII comma characters(hex
|
||
2C) to indicate a two-second pause during the dialing sequence.
|
||
If either the phone,fax, or email information is not available,
|
||
then a line should not included for this information.
|
||
NOTE: For interoperability purposes, it is advisable to use email
|
||
addresses formatted according to RFC 822 requirements.
|
||
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML SYSTEM-CONTACT.
|
||
The maximum
|
||
supported string length is 32 characters. If the user
|
||
entered string is too long, the device will store as
|
||
much as possible and will return the
|
||
<noError> status.
|
||
This object is saved in NVRAM."
|
||
::= { prtGeneralEntry 5 }
|
||
|
||
|
||
prtinputdefaultindex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The value of prtInputIndex corresponding to the default input
|
||
sub-unit: that is, this object selects the default source of
|
||
input media.
|
||
This value shall be -1 if there is no default input subunit specified
|
||
for the printer as a whole. In this case, the actual default
|
||
input subunit may be specified by means outside the scope of this
|
||
MIB, such as by each interpreter in a printer with multiple
|
||
interpreters.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
The default input tray is determined by the printer
|
||
based on DEFAULT-MEDIA-SIZE and DEFAULT-MEDIA-NAME. If multiple
|
||
trays have qualifying media, tray 1 is selected first, then the
|
||
non-empty tray with the highest capacity is selected; trays of
|
||
equal capacity are selected by lower tray number.
|
||
Trays 1-3 refer to the printer's trays that are so labeled.
|
||
Tray 4 is the first tray of the first external input paper
|
||
handling device."
|
||
::= { prtGeneralEntry 6 }
|
||
|
||
|
||
prtoutputdefaultindex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The value of prtOutputIndex corresponding to the default
|
||
output sub-unit; that is, this object selects the default
|
||
output destination.
|
||
This value shall be -1 if there is no default output subunit specified
|
||
for the printer as a whole. In this case, the actual default
|
||
output subunit may be specified by means outside the scope of this
|
||
MIB, such as by each interpreter in a printer with multiple
|
||
interpreters.
|
||
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtGeneralEntry 7 }
|
||
|
||
|
||
prtmarkerdefaultindex OBJECT-TYPE
|
||
SYNTAX INTEGER(1..65535)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The value of prtMarkerIndex corresponding to the
|
||
default marker sub-unit; that is, this object selects the
|
||
default marker.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtGeneralEntry 8 }
|
||
|
||
|
||
prtmediapathdefaultindex OBJECT-TYPE
|
||
SYNTAX INTEGER(1..3)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The value of prtMediaPathIndex corresponding to
|
||
the default media path; that is, the selection of the
|
||
default media path.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtGeneralEntry 9 }
|
||
|
||
|
||
prtconsolelocalization OBJECT-TYPE
|
||
SYNTAX INTEGER(1..16)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The value of the prtLocalizationIndex corresponding to
|
||
the language, country, and character set to be used for the
|
||
console. This localization applies both to the actual display
|
||
on the console as well as the encoding of these console
|
||
objects in management operations.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML LOCALIZATION-LANGUAGE.
|
||
The value of this object is saved in NVRAM.
|
||
If a localized string is currently being displayed on the
|
||
control panel by the device, changing this object will cause
|
||
the displayed string to be changed to its new value. If this
|
||
object is changed while the printer is processing a page that
|
||
contains localized strings has started, the results are
|
||
undefined."
|
||
::= { prtGeneralEntry 10 }
|
||
|
||
|
||
prtconsolenumberofdisplaylines OBJECT-TYPE
|
||
SYNTAX INTEGER(0..65535)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The number of lines on the printer's physical
|
||
display. This value is 0 if there are no lines on the
|
||
physical display or if there is no physical display
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML DISPLAY-NUMBER-OF-ROWS.
|
||
The printer has two physical lines on the display, however,
|
||
in many cases up to eight seperate lines of text may be
|
||
displayed by alternating pairs of lines every three seconds.
|
||
Thus the display really has eight logical lines for displaying
|
||
messages. This object will return the number of logical display
|
||
lines supported by the printer."
|
||
::= { prtGeneralEntry 11 }
|
||
|
||
|
||
prtconsolenumberofdisplaychars OBJECT-TYPE
|
||
SYNTAX INTEGER(0..65535)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The number of characters per line displayed on the physical
|
||
display. This value is 0 if there are no lines on the
|
||
physical display or if there is no physical display
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML DISPLAY-COLUMN-SIZE."
|
||
::= { prtGeneralEntry 12 }
|
||
|
||
|
||
prtconsoledisable OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePoperatorConsoleEnabled(3),
|
||
ePoperatorConsoleDisabled(4),
|
||
ePoperatorConsoleEnabledLevel1(5),
|
||
ePoperatorConsoleEnabledLevel2(6)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"If the object prtConsoleDisable has value
|
||
'operatorConsoleDisabled' then input is not accepted from the
|
||
operator console. If the object prtConsoleDisable has the value
|
||
'operatorConsoleEnabled' then input is accepted from the
|
||
operator console. If the object prtConsoleDisable has the value
|
||
'operatorConsoleEnabledLevel1','operatorConsoleEnabledLevel2' or
|
||
'operatorConsoleEnabledLevel3' then limited input is accepted
|
||
from the operator console; the limitations are product specific,
|
||
however, the limitations are generally less restrictive for
|
||
operatorConsoleEnabledLevel1 than for
|
||
operatorConsoleEnabledLeve2, which is less restrictive than
|
||
operatorConsoleEnabledLevel3.
|
||
The value of the prtConsoleDisable object is a type-2
|
||
enumeration.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML CONTROL-PANEL-LOCK.
|
||
If the object prtConsoleDisable has value
|
||
'ePoperatorConsoleDisabled' then manual input is not
|
||
accepted from the operator console. If the object
|
||
prtConsoleDisable has the value
|
||
'ePoperatorConsoleEnabled' then manual input is
|
||
accepted from the operator console.
|
||
|
||
The following menus are locked with these corresponding
|
||
values:
|
||
ePoperatorConsoleEnabled (no locking)
|
||
ePoperatorConsoleEnabledLevel1 (minimal locking)
|
||
RESETS MENU
|
||
CONFIGURATION MENU
|
||
I/O MENU
|
||
CALIBRATION MENU
|
||
|
||
ePoperatorConsoleEnabledLevel2 (moderate locking)
|
||
PAPER HANDLING MENU
|
||
menus in level 1
|
||
|
||
ePoperatorConsoleDisabled (maximum locking)
|
||
PRINTING MENU
|
||
INFORMATION MENU
|
||
Job Cancel
|
||
menus in Levels 1 and 2."
|
||
::= { prtGeneralEntry 13 }
|
||
|
||
|
||
prtgeneralbannerpage OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePnotPresent(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Used to enable or disable printing banner pages at the
|
||
beginning of jobs. This is a master switch which applies
|
||
to all jobs, regardless of interpreter.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtGeneralEntry 15 }
|
||
|
||
|
||
prtcoverdescription OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The manufacturer provided cover sub-mechanism name in the
|
||
localization specified by prtGeneralCurrentLocalization.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtCoverEntry 2 }
|
||
|
||
|
||
prtcoverstatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePCoverOpen(3),
|
||
ePCoverClosed(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The status of this cover sub-unit.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML NOT-READY-DOOR-OPEN."
|
||
::= { prtCoverEntry 3 }
|
||
|
||
|
||
prtlocalizationlanguage OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..2))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A two character language code from ISO 639. Examples
|
||
en, gb, ca, fr, de.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
The languages supported by Color LaserJet8550 are English,
|
||
French, German, Italian, Spanish, Swedish, Danish, Norwegian,
|
||
Dutch, Finnish, and Portuguese."
|
||
::= { prtLocalizationEntry 2 }
|
||
|
||
|
||
prtlocalizationcountry OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..2))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A two character country code from ISO 3166, a blank string
|
||
(two space characters) shall indicate that the country is
|
||
not defined. Examples: US, FR, DE, ...
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
The languages supported by Color LaserJet8550 (and corresponding
|
||
country) are English (United States), French (France), German
|
||
(Germany), Italian (Italy), Spanish (Spain), Swedish (Sweden),
|
||
Danish (Denmark), Norwegian (Norway), Dutch (Netherlands),
|
||
Finnish (Finland), Portuguese (Portugal), Turkish (Turkey),
|
||
Polish (Poland), Russian (Russia), Czech (Czechoslovakia),
|
||
Hungarian (Hungary)."
|
||
::= { prtLocalizationEntry 3 }
|
||
|
||
|
||
prtlocalizationcharacterset OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePcsHPRoman8(2004)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The coded character set used for this localization.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtLocalizationEntry 4 }
|
||
|
||
|
||
prtstoragerefindex OBJECT-TYPE
|
||
SYNTAX INTEGER(1..65535)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The value of the hrDeviceIndex of the printer device that this
|
||
storageEntry is associated with.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtStorageRefEntry 2 }
|
||
|
||
|
||
prtdevicerefindex OBJECT-TYPE
|
||
SYNTAX INTEGER(1..65535)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The value of the hrDeviceIndex of the printer device that this
|
||
deviceEntry is associated with.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtDeviceRefEntry 2 }
|
||
|
||
|
||
prtinputtype OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePunknown(2),
|
||
ePsheetFeedAutoRemovableTray(3),
|
||
ePsheetFeedAutoNonRemovableTray(4),
|
||
ePsheetFeedManual(5),
|
||
ePcontinuousRoll(6),
|
||
ePcontinuousFanFold(7)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The type of technology (discriminated primarily according to
|
||
feeder mechanism type) employed by the input sub-unit. Note,
|
||
the Optional Input Class provides for a descriptor field to
|
||
further qualify the other choice.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Tray 1 is the multi-purpose tray and is always present.
|
||
Tray 1 can operate in manual feed mode and supports
|
||
both sheets and envelopes. its type is
|
||
ePsheetFeedAutoNonRemovableTray.
|
||
Color LaserJet8550 base model does not support tray 2.
|
||
Trays 2 (8550 N and up) and 3 are the
|
||
drawers and, although they are usually not removed
|
||
from the printer, the printer cannot distinguish the
|
||
open and removed conditions. Therefore, when they are
|
||
open, they are considered to be removed and, for
|
||
this object, they are considered to be of type
|
||
ePsheetFeedAutoRemovableTray.
|
||
Tray 4 is the high capacity input device. ."
|
||
::= { prtInputEntry 2 }
|
||
|
||
|
||
prtinputdimunit OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePtenThousandthsOfInches(3),
|
||
ePmicrometers(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The unit of measurement for use calculating and relaying
|
||
dimensional values for this input sub-unit.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtInputEntry 3 }
|
||
|
||
|
||
prtinputmediadimfeeddirdeclared OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object provides the value of the declared dimension, in
|
||
the feed direction, of the media that is (or, if empty, was or
|
||
will be) in this input sub-unit. The feed direction is the
|
||
direction in which the media is fed on this sub-unit. This
|
||
dimension is measured in input sub-unit dimensional units
|
||
(prtInputDimUnit). If this input sub-unit can reliably sense
|
||
this value, the value is sensed by the printer and may not be
|
||
changed by management requests. Otherwise, the value may be
|
||
changed. The value (-1) means other and specifically means
|
||
that this sub-unit places no restriction on this parameter.
|
||
The value (-2) indicates unknown.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
For trays 2 (8550 N and up), 3 and 4 (which can
|
||
reliably sense this value) the objects behave exactly the
|
||
same as prtInputMediaDimFeedDirChosen.
|
||
Attempting to set this object for trays 2, 3 and 4 will cause
|
||
<noSuchName> to be returned.
|
||
The default values assume the trays are configured for
|
||
letter size paper.
|
||
For tray 1 the value is the dimension for the media size
|
||
currently declared."
|
||
::= { prtInputEntry 4 }
|
||
|
||
|
||
prtinputmediadimxfeeddirdeclared OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object provides the value of the declared dimension, in
|
||
the cross feed direction, of the media that is (or, if empty,
|
||
was or will be) in this input sub-unit. The cross feed
|
||
direction is ninety degrees relative to the feed direction
|
||
associated with this sub-unit. This dimension is measured in
|
||
input sub-unit dimensional units (prtInputDimUnit). If this
|
||
input sub-unit can reliably sense this value, the value is
|
||
sensed by the printer and may not be changed by management
|
||
requests. Otherwise, the value may be changed. The value (-1)
|
||
means other and specifically means that this sub-unit places
|
||
no restriction on this parameter. The value (-2) indicates
|
||
unknown.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
For trays 2 (8550 N and up), 3 and 4 (which can
|
||
reliably sense this value) the objects behave exactly the
|
||
same as prtInputMediaDimXFeedDirChosen.
|
||
Attempting to set this object for trays 2, 3 and 4 will cause
|
||
<noSuchName> to be returned.
|
||
The default values assume the trays are configured for
|
||
letter size paper.
|
||
For tray 1 the value is the dimension for the media size
|
||
currently declared."
|
||
::= { prtInputEntry 5 }
|
||
|
||
|
||
prtinputmediadimfeeddirchosen OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The printer will act as if media of the chosen dimension (in
|
||
the feed direction) is present in this input source. Note
|
||
that this value will be used even if the input tray is empty.
|
||
Feed dimension measurements are taken relative to the feed
|
||
direction associated with that sub-unit and are in input sub-unit
|
||
dimensional units (MediaUnit). If the printer supports the
|
||
declared dimension, the granted dimension is the same as
|
||
the declared dimension. If not, the granted dimension is
|
||
set to the closest dimension that the printer supports
|
||
when the declared dimension is set. The value (-1) means
|
||
other and specifically indicates that this sub-unit
|
||
places no restriction on this parameter. The value (-2)
|
||
indicates unknown.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
The objects for trays 2 (8550 N and up), 3 and 4
|
||
reflect the configuration of the corresponding drawers.
|
||
When the drawer is open, a value of -2 is returned.
|
||
The default values assume the trays are configured for
|
||
letter size paper.
|
||
The object for trays 1 returns the value of the
|
||
media size for which the tray is currently configured."
|
||
::= { prtInputEntry 6 }
|
||
|
||
|
||
prtinputmediadimxfeeddirchosen OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The printer will act as if media of the chosen dimension (in
|
||
the cross feed direction) is present in this input source.
|
||
Note that this value will be used even if the input tray is
|
||
empty. The cross feed direction is ninety degrees relative
|
||
to the feed direction associated with this sub-unit. This
|
||
dimension is measured in input sub-unit dimensional units
|
||
(MediaUnit). If the printer supports the declared
|
||
dimension, the granted dimension is the same as the
|
||
declared dimension. If not, the granted dimension is set
|
||
to the closest dimension that the printer supports when
|
||
the declared dimension is set. The value (-1) means other
|
||
and specifically indicates that this sub-unit places no
|
||
restriction on this parameter. The value (-2) indicates
|
||
unknown.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
The objects for trays 2 (8550 N and up), 3 and 4
|
||
reflect the configuration of the corresponding drawers.
|
||
When the drawer is open, a value of -2 is returned.
|
||
The default values assume the trays are configured for letter
|
||
size paper.
|
||
The object for trays 1 returns the value of the media
|
||
size for which the tray is currently configured."
|
||
::= { prtInputEntry 7 }
|
||
|
||
|
||
prtinputcapacityunit OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePtenThousandthsOfInches(3),
|
||
ePmicrometers(4),
|
||
ePsheets(8),
|
||
ePfeet(16),
|
||
ePmeters(17)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The unit of measurement for use in calculating and relaying
|
||
capacity values for this input sub-unit.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
A sheet is a single piece of 20 pound paper. "
|
||
::= { prtInputEntry 8 }
|
||
|
||
|
||
prtinputmaxcapacity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The maximum capacity of the input sub-unit in input
|
||
sub-unit capacity units (PrtCapacityUnitTC). There is no
|
||
convention associated with the media itself so this value
|
||
reflects claimed capacity. If this input sub-unit can
|
||
reliably sense this value, the value is sensed by the
|
||
printer and may not be changed by management requests;
|
||
otherwise, the value may be written (by a Remote
|
||
Control Panel or a Management Application).
|
||
The value (-1) means other and specifically
|
||
indicates that the sub-unit places no restrictions
|
||
on this parameter. The value (-2) means unknown.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML TRAYn-MAXIMUM-CAPACITY.
|
||
Color LaserJet8550 base model does not support tray 2.
|
||
The max capacity of the Matterhorn HCI is 1000."
|
||
::= { prtInputEntry 9 }
|
||
|
||
|
||
prtinputcurrentlevel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The current capacity of the input sub-unit in input
|
||
sub-unit capacity units (PrtCapacityUnitTC). If this input
|
||
sub-unit can reliably sense this value, the value is
|
||
sensed by the printer and may not be changed by
|
||
management requests; otherwise, the value may
|
||
be written (by a Remote Contol Panel or a
|
||
Management Application). The value (-1) means other and
|
||
specifically indicates that the sub-unit places no
|
||
restrictions on this parameter. The value (-2) means unknown.
|
||
The value (-3) means that the printer knows that at least one
|
||
unit remains.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
For trays 1, Color LaserJet8550 can only detect empty/not
|
||
empty trays. It returns -3 for not empty and 0 for
|
||
empty.
|
||
For trays 2 (8550 N and up) and 3, Color LaserJet8550 can detect
|
||
approximately the amount of media. The value returned
|
||
is based on the amount detected as follows:
|
||
0 - empty
|
||
1 - 1-110 sheets
|
||
50 - 50-260 sheets
|
||
200 - 200-490 sheets
|
||
430 - 430 sheets or more
|
||
For tray 4, Color LaserJet8550 can detect approximately the amount
|
||
of media. The value returned is based on the amount
|
||
detected as follows:
|
||
0 - empty
|
||
1 - 1 sheet to 25% of capacity
|
||
500 - 26% to 50% of capacity
|
||
1000 - 51% to 75% of capacity
|
||
1500 - 76% to 100% of capacity
|
||
If the tray drawer is open, a value of -2 (unknown)
|
||
will be returned."
|
||
::= { prtInputEntry 10 }
|
||
|
||
|
||
prtinputstatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The current status of this input sub-unit.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML STATUS-TRAY-MISSING and
|
||
STATUS-TRAY-EMPTY.
|
||
See SubUnitStatus in RFC1759 Printer MIB for details on
|
||
values reported by this object. Color LaserJet8550 will not include
|
||
values Available and Standby (2), Available and Active (4)
|
||
or Unknown (5)."
|
||
::= { prtInputEntry 11 }
|
||
|
||
|
||
prtinputmedianame OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A description of the media contained in this input sub-unit;
|
||
This description is intended for display to a human operator.
|
||
This description is not processed by the printer. It is used
|
||
to provide information not expressible in terms of the other
|
||
media attributes (e.g. prtInputMediaDimFeedDirChosen,
|
||
prtInputMediaDimXFeedDirChosen, prtInputMediaWeight,
|
||
prtInputMediaType). An example would be `legal tender bond
|
||
paper'.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML TRAYn-MEDIA-NAME.
|
||
If set to a string other than one contained by a MEDIAn-NAME
|
||
object, a status of <badValue> is
|
||
returned."
|
||
::= { prtInputEntry 12 }
|
||
|
||
|
||
prtinputname OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The name assigned to this input sub-unit.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML TRAYn-NAME."
|
||
::= { prtInputEntry 13 }
|
||
|
||
|
||
prtinputvendorname OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The vendor name of this input sub-unit.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtInputEntry 14 }
|
||
|
||
|
||
prtinputmodel OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The model name of this input sub-unit.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML objects PHDn-MODEL.
|
||
Color LaserJet8550 base model does not support tray 2."
|
||
::= { prtInputEntry 15 }
|
||
|
||
|
||
prtinputversion OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The version of this input sub-unit.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML objects PHDn-MANUFACTURING-INFO.
|
||
Color LaserJet8550 base model does not support tray 2."
|
||
::= { prtInputEntry 16 }
|
||
|
||
|
||
prtinputserialnumber OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The serial number assigned to this input sub-unit.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtInputEntry 17 }
|
||
|
||
|
||
prtinputdescription OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A free-form text description of this input
|
||
sub-unit in the localization specified by
|
||
prtGeneralCurrentLocalization.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtInputEntry 18 }
|
||
|
||
|
||
prtinputsecurity OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePon(3),
|
||
ePoff(4),
|
||
ePnotPresent(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates if this input sub-unit has some security
|
||
associated with it.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
No security mechanism provided."
|
||
::= { prtInputEntry 19 }
|
||
|
||
|
||
prtoutputtype OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePunknown(2),
|
||
ePremovableBin(3),
|
||
ePunRemovableBin(4),
|
||
ePcontinuousRollDevice(5),
|
||
ePmailBox(6),
|
||
ePcontinousFanFold(7)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The type of technology supported by this output sub-unit.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtOutputEntry 2 }
|
||
|
||
|
||
prtoutputcapacityunit OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePtenThousandthsOfInches(3),
|
||
ePmicrometers(4),
|
||
ePsheets(8),
|
||
ePfeet(16),
|
||
ePmeters(17)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The unit of measurement for use in calculating and relaying
|
||
capacity values for this output sub-unit.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
A sheet is a single piece of 20 pound paper."
|
||
::= { prtOutputEntry 3 }
|
||
|
||
|
||
prtoutputmaxcapacity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The maximum capacity of this output sub-unit in output
|
||
sub-unit capacity units (PrtCapacityUnitTC). There is no
|
||
convention associated with the media itself so this value
|
||
essentially reflects claimed capacity. If this output
|
||
sub-unit can reliably sense this value, the value is
|
||
sensed by the printer and may not be changed by management
|
||
requests; otherwise, the value may be written
|
||
(by a Remote Control Panel or a Management Application).
|
||
The value (-1) means other and specifically indicates
|
||
that the sub-unit places no restrictions on this parameter.
|
||
The value (-2) means unknown.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML OUTBINn-MAXIMUM-CAPACITY.
|
||
Output sub-unit 2 is not supported if any output paper
|
||
handling device is attached.
|
||
The capacity of sub-unit 4 depends on the mode of operation.
|
||
The capcities are as follows:
|
||
Stacker: 3000 letter papers (sub-units 5-11 do not exist)
|
||
Job Separator: 250 (sub-units 5-11 do not exist)
|
||
Stapler: 125 (sub-units 5 - 11 do not exist)
|
||
Mailbox: 250 (this is the default mode)"
|
||
::= { prtOutputEntry 4 }
|
||
|
||
|
||
prtoutputremainingcapacity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The remaining capacity of the possible output sub-unit
|
||
capacity in output sub-unit capacity units (PrtCapacityUnitTC)
|
||
of this output sub-unit. If this output sub-unit can
|
||
reliably sense this value, the value is sensed by the
|
||
printer and may not be modified by management requests;
|
||
otherwise, the value may be written (by
|
||
a Remote Control Panel or a Management
|
||
Application). The value (-1) means other and
|
||
specifically indicates that the sub-unit places no
|
||
restrictions on this parameter. The value (-2) means
|
||
unknown. The value (-3) means that the printer knows that
|
||
there remains capacity for at least one unit.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML NOT-READY-OUTBIN-FULL and
|
||
STATUS-OUTBIN-FULL.
|
||
The values reported for output sub-unit 1 (face-down, top bin)
|
||
will be either (-3) if it is not full or (0) if it is full.
|
||
Output sub-unit 2 (face-up, left side bin) does not have any
|
||
sensing, so it will always report unknown (-2).
|
||
The first output sub-unit (3) of the HCO reports either (62)
|
||
if it is not full, (125) when empty, or (0) if it is full.
|
||
In mailbox mode, the HCO sub-units (4-11) will report (250)
|
||
when empty, (125) when there's room for <250 sheets and (0)
|
||
when full.
|
||
In stacker and job separator modes all bins are treated as a
|
||
single output bin so sub-unit 4 will report (2000) when all
|
||
bins are empty. A value of (0) is reported when the topmost
|
||
bin is full (stacker mode) or when a bins is full
|
||
(separator mode).
|
||
When the stacker or separator has started filling, the value
|
||
reported is based on the number of bins that are empty,
|
||
partially filled and full.
|
||
A percentage is calculated based on the status of each bin.
|
||
Each full bin counts 1, each not empty/not full bin counts
|
||
0.5 and each empty bin counts 0. The result is mapped to an
|
||
estimate of the remaining capacity as follows (percent full
|
||
is included here for completeness, since that is how the
|
||
HCO reports it to the printer):
|
||
0.0 2000 (100%)
|
||
0.5 1900 ( 90%)
|
||
1.0 1800 ( 85%)
|
||
1.5 1700 ( 80%)
|
||
2.0 1500 ( 75%)
|
||
2.5 1400 ( 65%)
|
||
3.0 1300 ( 60%)
|
||
3.5 1200 ( 55%)
|
||
4.0 1000 ( 50%)
|
||
4.5 900 ( 40%)
|
||
5.0 800 ( 35%)
|
||
5.5 700 ( 30%)
|
||
6.0 500 ( 25%)
|
||
6.5 400 ( 15%)
|
||
7.0 300 ( 10%)
|
||
7.5 200 ( 5%)
|
||
8.0 0 ( 0%)
|
||
Note: Due to HCO mechanism limitations, the value reported may
|
||
not always be accurate (the bin status is detected only when
|
||
the media delivery head is moved to or past a physical bin).
|
||
Also, for stacker mode a bin is considered full as long as any
|
||
bin above it is not empty.
|
||
Default values assume all sub-units are empty and the HCO is
|
||
in mailbox mode."
|
||
::= { prtOutputEntry 5 }
|
||
|
||
|
||
prtoutputstatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The current status of this output sub-unit.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML NOT-READY-OUTBIN-MISSING and
|
||
STATUS-OUTBIN-MISSING.
|
||
The default values assume all bins are empty.
|
||
See SubUnitStatus in RFC1759 Printer MIB for details on
|
||
values reported by this object. Color LaserJet8550 will not include
|
||
values Available and Standby (2), Available and Active (4),
|
||
Unknown (5) or Transitioning to intended state (64)."
|
||
::= { prtOutputEntry 6 }
|
||
|
||
|
||
prtoutputname OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..19))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The name assigned to this output sub-unit.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML OUTBINn-NAME.
|
||
The characters must be in the range 20H to 7FH except 5C.
|
||
When this string is displayed on the control panel the
|
||
Roman-8 symbol set is used.
|
||
The object for bin 2 is not available when the HCO is attached."
|
||
::= { prtOutputEntry 7 }
|
||
|
||
|
||
prtoutputvendorname OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The vendor name of this output sub-unit.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
"
|
||
::= { prtOutputEntry 8 }
|
||
|
||
|
||
prtoutputmodel OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The name assigned to this output sub-unit.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
The value returned by this object depends on the
|
||
current mode of the device.
|
||
The possible values are as follows:
|
||
MULTIBIN MAILBOX C4785A
|
||
MULTIBIN STACKER C4785A
|
||
MULTIBIN SEPARATOR C4785A
|
||
STAPLER MODULE C3766A."
|
||
::= { prtOutputEntry 9 }
|
||
|
||
|
||
prtoutputversion OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The version of this output sub-unit.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Returns device-specific information about the configuration
|
||
of the output bin. May include information about the type of
|
||
processing that can be done to media sent to this bin;
|
||
processing includes but is not limited to binding, punching,
|
||
folding and sealing. Format of this object is specified by
|
||
the output device documentation."
|
||
::= { prtOutputEntry 10 }
|
||
|
||
|
||
prtoutputserialnumber OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The serial number assigned to this output sub-unit.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtOutputEntry 11 }
|
||
|
||
|
||
prtoutputdescription OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
" A free-form text description of this output sub-unit in the
|
||
localization specified by prtGeneralCurrentLocalization.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtOutputEntry 12 }
|
||
|
||
|
||
prtoutputsecurity OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePon(3),
|
||
ePoff(4),
|
||
ePnotPresent(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates if this output sub-unit has some security associated
|
||
with it and if that security is enabled or not.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
No security mechanism provided."
|
||
::= { prtOutputEntry 13 }
|
||
|
||
|
||
prtoutputstackingorder OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePunknown(2),
|
||
ePfirstToLast(3),
|
||
ePlastToFirst(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The current state of the stacking order for the
|
||
associated output sub-unit. `FirstToLast' means
|
||
that as pages are output the front of the next page is
|
||
placed against the back of the previous page.
|
||
`LasttoFirst' means that as pages are output the back
|
||
of the next page is placed against the front of the
|
||
previous page.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML OUTBINn-STACK-ORDER."
|
||
::= { prtOutputEntry 19 }
|
||
|
||
|
||
prtoutputpagedeliveryorientation OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePfaceUp(3),
|
||
ePfaceDown(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The reading surface that will be `up' when pages are
|
||
delivered to the associated output sub-unit. Values are
|
||
faceUp and faceDown. (Note: interpretation of these
|
||
values is in general context-dependent based on locale;
|
||
presentation of these values to an end-user should be
|
||
normalized to the expectations of the user).
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtOutputEntry 20 }
|
||
|
||
|
||
prtoutputbursting OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePon(3),
|
||
ePoff(4),
|
||
ePnotPresent(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object indicates that the outputting sub-unit
|
||
supports bursting, and if so, whether the feature is enabled.
|
||
Bursting is the process by which continuous media is separated
|
||
into individual sheets, typically by bursting along pre-formed
|
||
perforations.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Bursting is not supported.
|
||
For the base, outbins 1 and 2 are supported.
|
||
In stacker/stapler mode, outbins 1, 3, and 4 are
|
||
supported.
|
||
In MBM mode, outbins 1, 3 - 11 are supported."
|
||
::= { prtOutputEntry 21 }
|
||
|
||
|
||
prtoutputdecollating OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePon(3),
|
||
ePoff(4),
|
||
ePnotPresent(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object indicates that the output supports
|
||
supports decollating, and if so, whether the feature
|
||
is enabled. Decollating is the process by which the
|
||
individual parts within a multi-part form are separated
|
||
and sorted into separate stacks for each part.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Decollating is not supported."
|
||
::= { prtOutputEntry 22 }
|
||
|
||
|
||
prtoutputpagecollated OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePon(3),
|
||
ePoff(4),
|
||
ePnotPresent(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object indicates that the output sub-unit
|
||
supports page collation, and if so, whether the feature is
|
||
enabled. See glossary for definition of how this document defines
|
||
collation.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtOutputEntry 23 }
|
||
|
||
|
||
prtoutputoffsetstacking OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePon(3),
|
||
ePoff(4),
|
||
ePnotPresent(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object indicates that the output supports
|
||
supports offset stacking, and if so, whether the feature is
|
||
enabled. See glossary for how Offset Stacking is defined by this
|
||
document.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtOutputEntry 24 }
|
||
|
||
|
||
prtmarkermarktech OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePunknown(2),
|
||
ePelectrophotographicLED(3),
|
||
ePelectrophotographicLaser(4),
|
||
ePelectrophotographicOther(5),
|
||
ePimpactMovingHeadDotMatrix9pin(6),
|
||
ePimpactMovingHeadDotMatrix24pin(7),
|
||
ePimpactMovingHeadDotMatrixOther(8),
|
||
ePimpactMovingHeadFullyFormed(9),
|
||
ePimpactBand(10),
|
||
ePimpactOther(11),
|
||
ePinkjetAqueous(12),
|
||
ePinkjetSolid(13),
|
||
ePinkjetOther(14),
|
||
ePpen(15),
|
||
ePthermalTransfer(16),
|
||
ePthermalSensitive(17),
|
||
ePthermalDiffusion(18),
|
||
ePthermalOther(19),
|
||
ePelectroerosion(20),
|
||
ePelectrostatic(21),
|
||
ePphotographicMicrofiche(22),
|
||
ePphotographicImagesetter(23),
|
||
ePphotographicOther(24),
|
||
ePionDeposition(25),
|
||
ePeBeam(26),
|
||
ePtypesetter(27)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The type of marking technology used for this marking sub-unit.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtMarkerEntry 2 }
|
||
|
||
|
||
prtmarkercounterunit OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePtenThousandthsOfInches(3),
|
||
ePmicrometers(4),
|
||
ePcharacters(5),
|
||
ePlines(6),
|
||
ePimpressions(7),
|
||
ePsheets(8),
|
||
ePdotRow(9),
|
||
ePhours(11),
|
||
ePfeet(16),
|
||
ePmeters(17)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The unit that will be used by the printer when reporting
|
||
counter values for this marking sub-unit. The
|
||
time units of measure are provided for a device like a
|
||
strip recorder that does not or cannot track the physical
|
||
dimensions of the media and does not use characters,
|
||
lines or sheets.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtMarkerEntry 3 }
|
||
|
||
|
||
prtmarkerlifecount OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The count of the number of units of measure counted during
|
||
the life of printer using units of measure as specified by
|
||
prtMarkerCounterUnit.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML TOTAL-ENGINE-PAGE-COUNT.
|
||
In Color LaserJet8550 it is kept in NVRAM however the NVRAM value
|
||
is only updated every 10 impressions. NOTE: The value
|
||
returned by this OID will be incremented every page
|
||
but if power is lost between NVRAM updates, up to 9
|
||
impressions of the page count may be lost.
|
||
The counter will be reset to zero after 16,777,215
|
||
( 2^24-1) pages.
|
||
The page count is incremented when a sheet of media is
|
||
pulled from an input tray. A duplex printed sheet will
|
||
cause this counter to be incremented by two."
|
||
::= { prtMarkerEntry 4 }
|
||
|
||
|
||
prtmarkerpoweroncount OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The count of the number of units of measure counted since the
|
||
equipment was most recently powered on using units of measure as
|
||
specified by prtMarkerCounterUnit.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtMarkerEntry 5 }
|
||
|
||
|
||
prtmarkerprocesscolorants OBJECT-TYPE
|
||
SYNTAX INTEGER(0..65535)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The number of process colors supported by this marker. A
|
||
process color of 1 implies monochrome. The value of this
|
||
object and prtMarkerSpotColorants cannot both be 0. The value of
|
||
prtMarkerProcessColorants must be 0 or greater.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Color LaserJet8550 has four process colorants: Black, Cyan, Magenta,
|
||
and Yellow."
|
||
::= { prtMarkerEntry 6 }
|
||
|
||
|
||
prtmarkerspotcolorants OBJECT-TYPE
|
||
SYNTAX INTEGER(0..65535)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The number of spot colors supported by this marker. The
|
||
value of this object and prtMarkerProcessColorants cannot
|
||
both be 0. Must be 0 or greater.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtMarkerEntry 7 }
|
||
|
||
|
||
prtmarkeraddressabilityunit OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePtenThousandthsOfInches(3),
|
||
ePmicrometers(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The unit of measure of distances, as applied to the marker's
|
||
resolution.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtMarkerEntry 8 }
|
||
|
||
|
||
prtmarkeraddressabilityfeeddir OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The maximum number of addressable marking positions in the feed
|
||
direction per 10000 units of measure specified by
|
||
prtMarkerAddressabilityUnit. A value of (-1) implies 'other' or
|
||
'infinite' while a value of (-2) implies 'unknown'.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Use this object to specify resolution. Color LaserJet8550 only
|
||
supports 600 dpi."
|
||
::= { prtMarkerEntry 9 }
|
||
|
||
|
||
prtmarkeraddressabilityxfeeddir OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The maximum number of addressable marking positions in the cross
|
||
feed direction in 10000 units of measure specified by
|
||
prtMarkerAddressabilityUnit. A value of (-1) implies 'other' or
|
||
'infinite' while a value of (-2) implies 'unknown'.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Use this object to specify resolution. Color LaserJet8550 only
|
||
supports 600 dpi."
|
||
::= { prtMarkerEntry 10 }
|
||
|
||
|
||
prtmarkernorthmargin OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The margin, in units identified by prtMarkerAddressabilityUnit,
|
||
from the leading edge of the medium as the medium flows
|
||
through the marking engine with the side to be imaged
|
||
facing the observer. The leading edge is the North edge
|
||
and the other edges are defined by the normal compass
|
||
layout of directions with the compass facing the
|
||
observer. Printing within the area bounded by all four
|
||
margins is guaranteed for all interpreters. The value
|
||
(-2) means unknown.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtMarkerEntry 11 }
|
||
|
||
|
||
prtmarkersouthmargin OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The margin from the South edge (see prtMarkerNorthMargin)
|
||
of the medium in units identified by
|
||
prtMarkerAddressabilityUnit. Printing within the area bounded by
|
||
all four margins is guaranteed for all interpreters.
|
||
The value (-2) means unknown.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtMarkerEntry 12 }
|
||
|
||
|
||
prtmarkerwestmargin OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The margin from the West edge (see prtMarkerNorthMargin) of the
|
||
medium in units identified by prtMarkerAddressabilityUnit.
|
||
Printing within the area bounded by all four margins is
|
||
guaranteed for all interpreters. The value (-2) means
|
||
unknown.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtMarkerEntry 13 }
|
||
|
||
|
||
prtmarkereastmargin OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The margin from the East edge (see prtMarkerNorthMargin) of the
|
||
medium in units identified by prtMarkerAddressabilityUnit.
|
||
Printing within the area bounded by all four margins is
|
||
guaranteed for all interpreters. The value (-2) means
|
||
unknown.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtMarkerEntry 14 }
|
||
|
||
|
||
prtmarkerstatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The current status of this marker sub-unit.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML NOT-READY-DESTINATION-PRINT-ENGINE and
|
||
STATUS-DESTINATION-PRINT-ENGINE.
|
||
The default value assumes no malfunctions.
|
||
See SubUnitStatus in RFC1759 Printer MIB for details
|
||
on values reported by this object. Color LaserJet8550 will not
|
||
include values Available and Active (4) or Unknown (5)."
|
||
::= { prtMarkerEntry 15 }
|
||
|
||
|
||
prtmarkersuppliesmarkerindex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..65535)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The value of prtMarkerIndex corresponding to the
|
||
marking sub-unit with which this marker supply
|
||
sub-unit is associated.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtMarkerSuppliesEntry 2 }
|
||
|
||
|
||
prtmarkersuppliescolorantindex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..65535)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The value of prtMarkerColorantIndex
|
||
corresponding to the colorant with which this
|
||
marker supply sub-unit is associated. This value
|
||
shall be 0 if there is no colorant table.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtMarkerSuppliesEntry 3 }
|
||
|
||
|
||
prtmarkersuppliesclass OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePsupplyThatIsConsumed(3),
|
||
ePreceptacleThatIsFilled(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates whether this supply entity represents a supply
|
||
that is consumed or a receptacle that is filled.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtMarkerSuppliesEntry 4 }
|
||
|
||
|
||
prtmarkersuppliestype OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePunknown(2),
|
||
ePtoner(3),
|
||
ePwasteToner(4),
|
||
ePink(5),
|
||
ePinkCartridge(6),
|
||
ePinkRibbon(7),
|
||
ePwasteInk(8),
|
||
ePopc(9),
|
||
ePdeveloper(10),
|
||
ePfuserOil(11),
|
||
ePsolidWax(12),
|
||
ePribbonWax(13),
|
||
ePwasteWax(14),
|
||
ePfuser(15),
|
||
ePcoronaWire(16),
|
||
ePfuserOilWick(17),
|
||
ePcleanerUnit(18),
|
||
ePfuserCleaningPad(19),
|
||
ePtransferUnit(20),
|
||
ePtonerCartridge(21),
|
||
ePfuserOiler(22)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The type of this supply.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtMarkerSuppliesEntry 5 }
|
||
|
||
|
||
prtmarkersuppliesdescription OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The description of this supply container/receptacle in the
|
||
localization specified by prtGeneralCurrentLocalization.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtMarkerSuppliesEntry 6 }
|
||
|
||
|
||
prtmarkersuppliessupplyunit OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePtenThousandthsOfInches(3),
|
||
ePmicrometers(4),
|
||
ePimpressions(7),
|
||
ePsheets(8),
|
||
ePthousandthsOfOunces(12),
|
||
ePhours(11),
|
||
ePtenthsOfGrams(13),
|
||
ePhundrethsOfFluidOunces(14),
|
||
ePtenthsOfMilliliters(15),
|
||
ePfeet(16),
|
||
ePmeters(17)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Unit of measure of this marker supply container/receptacle.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtMarkerSuppliesEntry 7 }
|
||
|
||
|
||
prtmarkersuppliesmaxcapacity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The maximum capacity of this supply container/receptacle
|
||
expressed in prtMarkerSuppliesSupplyUnit. If this supply
|
||
container/receptacle can reliably sense this value, the
|
||
value is reported by the printer and is read-only;
|
||
otherwise, the value may be written (by a Remote Control
|
||
Panel or a Management Application). The value (-1) means
|
||
other and specifically indicates that the sub-unit places
|
||
no restrictions on this parameter. The value (-2) means
|
||
unknown.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtMarkerSuppliesEntry 8 }
|
||
|
||
|
||
prtmarkersupplieslevel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The current level if this supply is a container; the
|
||
remaining space if this supply is a receptacle. If this
|
||
supply container/receptacle can reliably sense this
|
||
value, the value is reported by the printer and is
|
||
read-only; otherwise, the value may be written (by a
|
||
Remote Control Panel or a Management Application). The
|
||
value (-1) means other and specifically indicates that
|
||
the sub-unit places no restrictions on this parameter.
|
||
The value (-2) means unknown. A value of (-3) means that the
|
||
printer knows that there is some supply/remaining space,
|
||
respectively.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Color LaserJet8550 detects two states for the toner:
|
||
Between the 'LOW' and 'LOW 2' thresholds will be
|
||
reported as -2.
|
||
At the 'LOW 2' threshold will be reported as 0.
|
||
The other consumables will report -2.
|
||
For Matterhorn, at printer initialization, all
|
||
consumables will default to -2. This value will not
|
||
change since Matterhorn cannot track consumables."
|
||
::= { prtMarkerSuppliesEntry 9 }
|
||
|
||
|
||
prtmediapathmaxspeedprintunit OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePtenThousandthsOfInchesPerHour(3),
|
||
ePmicrometersPerHour(4),
|
||
ePcharactersPerHour(5),
|
||
ePlinesPerHour(6),
|
||
ePimpressionsPerHour(7),
|
||
ePsheetsPerHour(8),
|
||
ePdotRowPerHour(9),
|
||
ePfeetPerHour(16),
|
||
ePmetersPerHour(17)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The unit of measure used in specifying the speed of all media
|
||
paths in the printer.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtMediaPathEntry 2 }
|
||
|
||
|
||
prtmediapathmediasizeunit OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePtenThousandthsOfInches(3),
|
||
ePmicrometers(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The units of measure of media size for use in calculating and
|
||
relaying dimensional values for all media paths in the printer.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtMediaPathEntry 3 }
|
||
|
||
|
||
prtmediapathmaxspeed OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The maximum printing speed of this media path expressed in
|
||
prtMediaPathMaxSpeedUnit's. A value of (-1) implies
|
||
'other'.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML PRINT-ENGINE-PERFORMANCE.
|
||
The page size for this performance is 8.5x11."
|
||
::= { prtMediaPathEntry 4 }
|
||
|
||
|
||
prtmediapathmaxmediafeeddir OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The maximum physical media size in the feed direction of this
|
||
media path expressed in units of measure specified by
|
||
PrtMediaPathMediaSizeUnit. A value of (-1) implies 'unlimited',
|
||
a value of (-2) implies 'unknown'.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
The value returned by this object depends on the value
|
||
of prtMediaPathMediaSizeUnit. It is 185000 if
|
||
prtMediaPathMediaSizeUnit is ePtenThousandthsOfInches or
|
||
469900 if prtMediaPathMediaSizeUnit is ePmicrometers."
|
||
::= { prtMediaPathEntry 5 }
|
||
|
||
|
||
prtmediapathmaxmediaxfeeddir OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The maximum physical media size across the feed direction of
|
||
this media path expressed in units of measure specified by
|
||
prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
The value returned by this object depends on the value
|
||
of prtMediaPathMediaSizeUnit. It is 120000 if
|
||
prtMediaPathMediaSizeUnit is ePtenThousandthsOfInches or
|
||
304800 if prtMediaPathMediaSizeUnit is ePmicrometers."
|
||
::= { prtMediaPathEntry 6 }
|
||
|
||
|
||
prtmediapathminmediafeeddir OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The minimum physical media size in the feed direction of this
|
||
media path expressed in units of measure specified by
|
||
prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
The value returned by this object depends on the value
|
||
of prtMediaPathMediaSizeUnit. For the simplex paper path it is
|
||
74803 if prtMediaPathMediaSizeUnit is ePtenThousandthsOfInches
|
||
or 189999 if prtMediaPathMediaSizeUnit is ePmicrometers.
|
||
For the duplex paper path it is 82677 if
|
||
prtMediaPathMediaSizeUnit is ePtenThousandthsOfInches or
|
||
210000 if prtMediaPathMediaSizeUnit is ePmicrometers.
|
||
This sizes correspond to a custom paper length for simplex,
|
||
A5 paper length for duplex ( Note: The simallest paper size for simplex must be fed portrait)."
|
||
::= { prtMediaPathEntry 7 }
|
||
|
||
|
||
prtmediapathminmediaxfeeddir OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The minimum physical media size across the feed direction of
|
||
this media path expressed in units of measure specified by
|
||
prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
The value returned by this object depends on the value
|
||
of prtMediaPathMediaSizeUnit. For the simplex paper path, it is
|
||
38740 if prtMediaPathMediaSizeUnit is ePtenThousandthsOfInches
|
||
or 98400 if prtMediaPathMediaSizeUnit is ePmicrometers.
|
||
For the duplex paper path it is 58267 if
|
||
prtMediaPathMediaSizeUnit is ePtenThousandthsOfInches or
|
||
148000 if prtMediaPathMediaSizeUnit is ePmicrometers.
|
||
This size corresponds to a custom paper width for the simplex,
|
||
A5 paper width for duplex."
|
||
::= { prtMediaPathEntry 8 }
|
||
|
||
|
||
prtmediapathtype OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePlongEdgeBindingDuplex(3),
|
||
ePshortEdgeBindingDuplex(4),
|
||
ePsimplex(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The type of the media path for this media path.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML DUPLEX-INSTALLED."
|
||
::= { prtMediaPathEntry 9 }
|
||
|
||
|
||
prtmediapathdescription OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The manufacturer-provided description of this media path in
|
||
the localization specified by prtGeneralCurrentLocalization.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtMediaPathEntry 10 }
|
||
|
||
|
||
prtmediapathstatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The current status of this media path.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
The default values assume the printer is idle.
|
||
See SubUnitStatus in RFC1759 Printer MIB for details on
|
||
values reported by this object. Color LaserJet8550 will not include values
|
||
Available and Standby (2), Available and Active (4),
|
||
Unknown (5), Non-CriticalAlerts (8) or Transitioning
|
||
to intended state (64)."
|
||
::= { prtMediaPathEntry 11 }
|
||
|
||
|
||
prtchanneltype OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePchIEEE1284Port(5),
|
||
ePchAppleTalkPAP(7),
|
||
ePchNetwarePServer(10),
|
||
ePchDLCLLCPort(15),
|
||
ePchBidirPortTCP(38)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The type of this print data channel. This
|
||
object provides the linkage to ChannelType-specific
|
||
groups that may (conceptually) extend the prtChannelTable
|
||
with additional details about that channel.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
This object, in conjunction with
|
||
prtChannelProtocolVersion, replaces the PML object
|
||
PORTn-DESCRIPTION.
|
||
MIO-based channels provide their own values.
|
||
There are 34 channel types for Color LaserJet8550; first two being
|
||
parallel, 3 - 18 are for the first card, and 19 - 34
|
||
are for the second card. If a card wants to use all
|
||
16 channels at a given time, it can. But a card could
|
||
use less than 16 channels at a given time."
|
||
::= { prtChannelEntry 2 }
|
||
|
||
|
||
prtchannelprotocolversion OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The version of the protocol used on this
|
||
channel. The format used for version numbering depends
|
||
on prtChannelType.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
This object, in conjunction with
|
||
prtChannelType, replaces the PML object PORTn-DESCRIPTION.
|
||
|
||
MIO-based channels provide their own values.
|
||
The channel 1 value includes (separated by semi colons)
|
||
different aspects of the spec: electrical;logical; and
|
||
physical connector."
|
||
::= { prtChannelEntry 3 }
|
||
|
||
|
||
prtchannelcurrentjobcntllangindex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The value of prtInterpreterIndex corresponding to the
|
||
Control Language Interpreter for this channel. This
|
||
interpreter defines the syntax used for control
|
||
functions, such as querying or changing environment
|
||
variables and identifying job boundaries (e.g. PJL,
|
||
PostScript, NPAP). Must be 1 or greater.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
This object points to the PJL language. It is
|
||
read-only because PJL (2) is the printer's only job
|
||
control language. It is the same for all channels."
|
||
::= { prtChannelEntry 4 }
|
||
|
||
|
||
prtchanneldefaultpagedesclangindex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The value of prtInterpreterIndex corresponding to the
|
||
Page Description Language Interpreter for this channel.
|
||
This interpreter defines the default Page Description
|
||
Language interpreter to be used for the print data unless
|
||
the Control Language is used to select a specific
|
||
interpreter (e.g., PCL, PostScript Language,
|
||
auto-sense). Must be 1 or greater.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML DEFAULT-PDL.
|
||
The default points to the automatic language switcher.
|
||
If this object is changed for one channel, all channels
|
||
will be changed."
|
||
::= { prtChannelEntry 5 }
|
||
|
||
|
||
prtchannelstate OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePprintDataAccepted(3),
|
||
ePnoDataAccepted(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The state of this print data channel. The value determines
|
||
whether control information and print data is allowed through
|
||
this channel or not.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
MIO-based channels provide their own values for this
|
||
object.
|
||
The base-printer's port always reports a value of
|
||
ePprintDataAccepted. If the printer is offline, that is
|
||
detected by reading the Host Resources General Printer Status
|
||
objects, not by reading this object."
|
||
::= { prtChannelEntry 6 }
|
||
|
||
|
||
prtchannelifindex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The value of ifIndex (in the ifTable; see the interface
|
||
section of MIB-2/RFC 1213) which corresponds to this channel.
|
||
When more than one row of the ifTable is relevant, this is
|
||
the index of the row representing the topmost layer in the
|
||
interface hierarchy. A value of zero indicates that no
|
||
interface is associated with this channel.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
MIO-based channels provide their own values for
|
||
this object."
|
||
::= { prtChannelEntry 7 }
|
||
|
||
|
||
prtchannelstatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The current status of the channel.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
See SubUnitStatus in RFC1759 Printer MIB for details
|
||
on values reported by this object. MIO-based channels provide
|
||
their own values for this object. Status for Color LaserJet8550's parallel
|
||
port will not include values Available and Standby (2),
|
||
Available and Active (4), Non-Critical Alerts (8) or
|
||
Transitioning to intended state (64)."
|
||
::= { prtChannelEntry 8 }
|
||
|
||
|
||
prtinterpreterlangfamily OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePlangPCL(3),
|
||
ePlangPJL(5),
|
||
ePlangPS(6),
|
||
ePlangAutomatic(37)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The family name of a Page Description Language (PDL) or
|
||
control language which this interpreter in the printer can
|
||
interpret or emulate.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PCL-NAME and FW-ROM-DATECODE ( sort of).
|
||
Also provides a place to supply PJL information and
|
||
overall ROM information ( by using the language
|
||
switcher as a separate language)."
|
||
::= { prtInterpreterEntry 2 }
|
||
|
||
|
||
prtinterpreterlanglevel OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..31))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The level of the language which this interpreter is
|
||
interpreting or emulating. This might contain a value like
|
||
'5e' for an interpreter which is emulating level 5e of the PCL
|
||
language. It might contain '2' for an interpreter which is
|
||
emulating level 2 of the PostScript language. Similarly it
|
||
might contain '2' for an interpreter which is emulating level
|
||
2 of the HPGL language.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtInterpreterEntry 3 }
|
||
|
||
|
||
prtinterpreterlangversion OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..31))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The date code or version of the language which this interpreter
|
||
is interpreting or emulating.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
This is a date code determined by the firmware build
|
||
engineer. The value of these objects will change from
|
||
build to build and the final value will be determined
|
||
at some later date. At that time the default values
|
||
will be changed to reflect the final value."
|
||
::= { prtInterpreterEntry 4 }
|
||
|
||
|
||
prtinterpreterdescription OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A string to identify this interpreter in the localization
|
||
specified by prtGeneralCurrentLocalization as opposed to the
|
||
language which is being interpreted. It is anticipated that
|
||
this string will allow manufacturers to unambiguously identify
|
||
their interpreters.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
None of these strings are localized."
|
||
::= { prtInterpreterEntry 5 }
|
||
|
||
|
||
prtinterpreterversion OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..31))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The date code, version number, or other product specific
|
||
information tied to this interpreter. This value is
|
||
associated with the interpreter, rather than with the version
|
||
of the language which is being interpreted or emulated.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Same as prtInterpreterLangVersion."
|
||
::= { prtInterpreterEntry 6 }
|
||
|
||
|
||
prtinterpreterdefaultorientation OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePportrait(3),
|
||
ePlandscape(4)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The current orientation default for this interpreter. This
|
||
value may be overridden for a particular job (e.g., by a
|
||
command in the input data stream).
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML DEFAULT-ORIENTATION.
|
||
Setting this object for one interpreter will change it
|
||
for all installed interpreters.
|
||
The automatic language switching and PJL interpreters
|
||
ignore the value of this object.
|
||
The value for PCL is either ePportrait or ePlandscape;
|
||
attempting to set it to a different value will cause
|
||
<badValue> to be returned."
|
||
::= { prtInterpreterEntry 7 }
|
||
|
||
|
||
prtinterpreterfeedaddressability OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The maximum interpreter addressability in the feed
|
||
direction in 10000 prtMarkerAddressabilityUnits (see
|
||
prtMarkerAddressabilityFeedDir ) for this interpreter.
|
||
The value (-1) means other and specifically indicates
|
||
that the sub-unit places no restrictions on this parameter.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtInterpreterEntry 8 }
|
||
|
||
|
||
prtinterpreterxfeedaddressability OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The maximum interpreter addressability in the cross feed
|
||
direction in 10000 prtMarkerAddressabilityUnits (see
|
||
prtMarkerAddressabilityXFeedDir) for this interpreter.
|
||
The value (-1) means other and specifically indicates
|
||
that the sub-unit places no restrictions on this
|
||
parameter.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtInterpreterEntry 9 }
|
||
|
||
|
||
prtinterpreterdefaultcharsetin OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePcsISOLatin2(5),
|
||
ePcsISOLatinCyrillic(8),
|
||
ePcsISOLatin5(12),
|
||
ePcsHalfWidthKatakana(15),
|
||
ePcsHPRoman8(2004)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The default coded character set for input octets
|
||
encountered outside a context in which the Page
|
||
Description Language established the interpretation
|
||
of the octets. (Input octets are presented to the
|
||
interpreter through a path defined in the channel group.)
|
||
This value shall be (2) if there is no default.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
This object refers to PCL symbol set."
|
||
::= { prtInterpreterEntry 10 }
|
||
|
||
|
||
prtinterpreterdefaultcharsetout OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePcsNoDefault(2),
|
||
ePcsASCII(3),
|
||
ePcsHPRoman8(2004),
|
||
ePcsAdobeStandardEncoding(2005)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The default character set for data coming from this interpreter
|
||
through the printer's output channel (i.e. the 'backchannel').
|
||
This value shall be (2) if there is no default.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
"
|
||
::= { prtInterpreterEntry 11 }
|
||
|
||
|
||
prtinterpretertwoway OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePyes(3),
|
||
ePno(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates whether or not this interpreter returns information
|
||
back to the host.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtInterpreterEntry 12 }
|
||
|
||
|
||
prtconsoledisplaybuffertext OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The content of a line in the logical display buffer of
|
||
the operator's console of the printer. When a write
|
||
operation occurs, normally a critical message, to one of
|
||
the LineText strings, the agent should make that line
|
||
displayable if a physical display is present. Writing
|
||
a zero length string clears the line. It is an
|
||
implementation-specific matter as to whether the agent allows
|
||
a line to be overwritten before it has been cleared.
|
||
Printer generated strings shall be in the localization
|
||
specified by prtConsoleLocalization. Management Application
|
||
generated strings should be localized by the Management
|
||
Application.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
Replaces PML STATUS-MSG-LINE1-PART1 and
|
||
STATUS-MSG-LINE2-PART1.
|
||
The ojbects BACKGROUND-STATUS-MSG-LINE1-PART1
|
||
and BACKGROUND-STATUS-MSG-LINE2-PART1 should be used
|
||
to write messages to the control panel display.
|
||
prtConsoleDisplayBufferText[1..8] maps to logical line
|
||
[1..8] of the display.
|
||
Unused lines on the control pannel should retrun NULL."
|
||
::= { prtConsoleDisplayBufferEntry 2 }
|
||
|
||
|
||
prtconsoleontime OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object, in conjunction with prtConsoleOffTime, defines
|
||
the current status of the light. If both prtConsoleOnTime and
|
||
prtConsoleOffTime are non-zero, the lamp is blinking and the
|
||
values presented define the on time and off time, respectively,
|
||
in milliseconds. If prtConsoleOnTime is zero and
|
||
prtConsoleOffTime is non-zero, the lamp is off. If
|
||
prtConsoleOffTime is zero and prtConsoleOnTime is non-zero,
|
||
the lamp is on. If both values are zero the status of the
|
||
lamp is undefined.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
There are three control panel LED's: Ready ( index 1),
|
||
Data ( index 2) and Attention ( index 3).
|
||
The Ready and Data led flash at the rate of 500
|
||
milliseconds on followed by 500 milliseconds off.
|
||
The Attention led flashes at the rate of 250
|
||
milliseconds on followed by 250 milliseconds off."
|
||
|
||
::= { prtConsoleLightEntry 2 }
|
||
|
||
|
||
prtconsoleofftime OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object, in conjunction with prtConsoleOnTime, defines
|
||
the current status of the light. If both prtConsoleOnTime and
|
||
prtConsoleOffTime are non-zero, the lamp is blinking and the
|
||
values presented define the on time and off time, respectively,
|
||
in milliseconds. If prtConsoleOnTime is zero and
|
||
prtConsoleOffTime is non-zero, the lamp is off. If
|
||
prtConsoleOffTime is zero and prtConsoleOnTime is non-zero,
|
||
the lamp is on. If both values are zero the status of the
|
||
lamp is undefined.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
There are three control panel LED's: Ready( index 1),
|
||
Data ( index 2) and Attention ( index 3).
|
||
The Ready and Data led flash at the rate of 500
|
||
milliseconds on followed by 500 milliseconds off.
|
||
The Attention led flashes at the rate of 250
|
||
milliseconds on followed by 250 milliseconds off."
|
||
|
||
::= { prtConsoleLightEntry 3 }
|
||
|
||
|
||
prtconsolecolor OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePunknown(2),
|
||
ePwhite(3),
|
||
ePred(4),
|
||
ePgreen(5),
|
||
ePblue(6),
|
||
ePcyan(7),
|
||
ePmagenta(8),
|
||
ePyellow(9),
|
||
ePorange(10)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The color of this light.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtConsoleLightEntry 4 }
|
||
|
||
|
||
prtconsoledescription OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The vendor description or label of this light in the
|
||
localization specified by prtConsoleLocalization.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
|
||
::= { prtConsoleLightEntry 5 }
|
||
|
||
|
||
prtalertseveritylevel OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePcriticalBinaryChangeEvent(3),
|
||
ePwarningUnaryChangeEvent(4),
|
||
ePwarningBinaryChangeEvent(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The level of severity of this alert table entry. The printer
|
||
determines the severity level assigned to each entry into the
|
||
table.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
The alert table in Color LaserJet8550 will hold up to 233 entries."
|
||
::= { prtAlertEntry 2 }
|
||
|
||
|
||
prtalerttraininglevel OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePuntrained(3),
|
||
ePtrained(4),
|
||
ePfieldService(5),
|
||
ePmanagement(6)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"See textual convention PrtAlertTrainingLevelTC
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
The alert table in Color LaserJet8550 will hold up to 233 entries.
|
||
The value of this object depends on the alert condition
|
||
as follows:
|
||
ePuntrained: Paper out.
|
||
ePtrained: Toner out.
|
||
ePfieldService: Marker failure.
|
||
ePmanagement: Configuration change."
|
||
::= { prtAlertEntry 3 }
|
||
|
||
|
||
prtalertgroup OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePhostResourcesMIBStorageTable(3),
|
||
ePhostResourcesMIBDeviceTable(4),
|
||
ePgeneralPrinter(5),
|
||
ePcover(6),
|
||
ePlocalization(7),
|
||
ePinput(8),
|
||
ePoutput(9),
|
||
ePmarker(10),
|
||
ePmarkerSupplies(11),
|
||
ePmarkerColorant(12),
|
||
ePmediaPath(13),
|
||
ePchannel(14),
|
||
ePinterpreter(15),
|
||
ePconsoleDisplayBuffer(16),
|
||
ePconsoleLights(17)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The type of sub-unit within the printer model that this alert
|
||
is related. Input, output, and markers are examples of
|
||
printer model groups, i.e., examples of types of sub-units.
|
||
Wherever possible, these enumerations match the
|
||
sub-identifier that identifies the relevant table in the
|
||
printmib.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
The alert table in Color LaserJet8550 will hold up to 233 entries."
|
||
::= { prtAlertEntry 4 }
|
||
|
||
|
||
prtalertgroupindex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"An index of the row within the principle table in the
|
||
group identified by prtAlertGroup that represents the
|
||
sub-unit of the printer that caused this alert. The
|
||
combination of the prtAlertGroup and the prtAlertGroupIndex defines
|
||
exactly which printer sub-unit caused the alert.; for
|
||
example, Input #3, Output #2, and Marker #1.
|
||
Every object in this MIB is indexed with hrDeviceIndex and
|
||
optionally, another index variable. If this other index
|
||
variable is present in the table that generated the alert, it
|
||
will be used as the value for this object. Otherwise, this
|
||
value shall be -1.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
The alert table in Color LaserJet8550 will hold up to 233 entries."
|
||
::= { prtAlertEntry 5 }
|
||
|
||
|
||
prtalertlocation OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The sub-unit location that is defined by the printer
|
||
manufacturer to further refine the location of this alert
|
||
within the designated sub-unit. The location is used in
|
||
conjunction with the Group and GroupIndex values; for
|
||
example, there is an alert in Input #2 at location number 7.
|
||
The value (-2) indicates unknown
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
The alert table in Color LaserJet8550 will hold up to 233 entries."
|
||
::= { prtAlertEntry 6 }
|
||
|
||
|
||
prtalertcode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePunknown(2),
|
||
ePcoverOpened(3),
|
||
ePcoverClosed(4),
|
||
ePinterlockOpened(5),
|
||
ePinterlockClosed(6),
|
||
ePconfigurationChanged(7),
|
||
ePjammed(8),
|
||
ePsubunitMissing(9),
|
||
ePsubunitLifeAlmostOver(10),
|
||
ePsubunitLifeOver(11),
|
||
ePsubunitAlmostEmpty(12),
|
||
ePsubunitEmpty(13),
|
||
ePsubunitAlmostFull(14),
|
||
ePsubunitFull(15),
|
||
ePsubunitNearLimit(16),
|
||
ePsubunitAtLimit(17),
|
||
ePsubunitOpened(18),
|
||
ePsubunitClosed(19),
|
||
ePsubunitTurnedOn(20),
|
||
ePsubunitTurnedOff(21),
|
||
ePsubunitOffline(22),
|
||
ePsubunitPowerSaver(23),
|
||
ePsubunitWarmingUp(24),
|
||
ePsubunitAdded(25),
|
||
ePsubunitRemoved(26),
|
||
ePsubunitRecousrceAdded(27),
|
||
ePsubunitResourceRemoved(28),
|
||
ePsubunitRecoverableFailure(29),
|
||
ePsubunitUnrecoverableFailure(30),
|
||
ePsubunitRecoverableStorageError(31),
|
||
ePsubunitUnrecoverableStorageError(32),
|
||
ePsubunitMotorFailure(33),
|
||
ePsubunitMemoryExhausted(34),
|
||
ePcoverOpened(501),
|
||
ePcoverClosed(502),
|
||
ePpoweredUp(503),
|
||
ePpoweredDown(504),
|
||
ePprinterNMSReset(505),
|
||
ePprinterManualReset(506),
|
||
ePprinterReadyToPrint(507),
|
||
ePinputMediaTrayMissing(801),
|
||
ePinputMediaSizeChanged(802),
|
||
ePinputMediaWeightChanged(803),
|
||
ePinputMediaTypeChanged(804),
|
||
ePinputMediaColorChanged(805),
|
||
ePinputMediaFormPartsChange(806),
|
||
ePinputMediaSupplyLow(807),
|
||
ePinputMediaSupplyEmpty(808),
|
||
ePinputMediaChangeRequest(809),
|
||
ePinputManualInputRequest(810),
|
||
ePinputTrayPositionFailure(811),
|
||
ePinputTrayElevationFailure(812),
|
||
ePinputCannotFeedSizeSelected(813),
|
||
ePoutputMediaTrayMissing(901),
|
||
ePoutputMediaTrayAlmostFull(902),
|
||
ePoutputMediaTrayFull(903),
|
||
ePoutputMailboxSelectFailure(904),
|
||
ePmarkerFuserUnderTemperature(1001),
|
||
ePmarkerFuserOverTemperature(1002),
|
||
ePmarkerFuserTimingFailure(1003),
|
||
ePmarkerFuserThermistorFailure(1004),
|
||
ePmarkerAdjustingPrintQuality(1005),
|
||
ePmarkerTonerEmpty(1101),
|
||
ePmarkerInkEmpty(1102),
|
||
ePmarkerPrintRibbonEmpty(1103),
|
||
ePmarkerTonerAlmostEmpty(1104),
|
||
ePmarkerInkAlmostEmpty(1105),
|
||
ePmarkerPrintRibbonAlmostEmpty(1106),
|
||
ePmarkerWasteTonerReceptacleAlmostFull(1107),
|
||
ePmarkerWasteInkReceptacleAlmostFull(1108),
|
||
ePmarkerWasteTonerReceptacleFull(1109),
|
||
ePmarkerWasteInkReceptacleFull(1110),
|
||
ePmarkerOpcLifeAlmostOver(1111),
|
||
ePmarkerOpcLifeOver(1112),
|
||
ePmarkerDeveloperAlmostEmpty(1113),
|
||
ePmarkerDeveloperEmpty(1114),
|
||
ePmarkerTonerCartridgeMissing(1115),
|
||
ePmediaPathMediaTrayMissing(1301),
|
||
ePmediaPathMediaTrayAlmostFull(1302),
|
||
ePmediaPathMediaTrayFull(1303),
|
||
ePinterpreterMemoryIncreased(1501),
|
||
ePinterpreterMemoryDecreased(1502),
|
||
ePinterpreterCartridgeAdded(1503),
|
||
ePinterpreterCartridgeDeleted(1504),
|
||
ePinterpreterResourceAdded(1505),
|
||
ePinterpreterResourceDeleted(1506),
|
||
ePinterpreterResourceUnavailable(1507),
|
||
ePinterpreterComplexPageEncountered(1509),
|
||
ePalertRemovalOfBinaryChangeEntry(1801)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"See associated textual convention PrtAlertCodeTC
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
The alert table in Color LaserJet8550 will hold up to 233 entries."
|
||
::= { prtAlertEntry 7 }
|
||
|
||
|
||
prtalertdescription OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A description of this alert entry in the localization
|
||
specified by prtGeneralCurrentLocalization. The description is
|
||
provided by the printer to further elaborate on the enumerated
|
||
alert or provide information in the case where the code is
|
||
classified as `other' or `unknown'. The printer is required
|
||
to return a description string but the string may be a null
|
||
string.
|
||
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
|
||
Additional information:
|
||
The alert table in Color LaserJet8550 will hold up to 233 entries."
|
||
::= { prtAlertEntry 8 }
|
||
|
||
|
||