Observium_CE/mibs/hirschmann/HMIOMODULE-SNMP-MIB

454 lines
19 KiB
Plaintext

HMIOMODULE-SNMP-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-IDENTITY,
OBJECT-TYPE, NOTIFICATION-TYPE,
Integer32, IpAddress FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
DisplayString FROM SNMPv2-TC
hmChassis, hmChassisEvent FROM HMPRIV-MGMT-SNMP-MIB
InetPortNumber FROM INET-ADDRESS-MIB;
HmEnabledStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Status of a feature"
SYNTAX INTEGER {
enable(1), -- feature is enabled
disable(2) -- feature is disabled
}
-- *************************************************************************
-- Group IO Module
-- *************************************************************************
hmIOModuleGroup MODULE-IDENTITY
LAST-UPDATED "201011081500Z" -- 08 Nov 2010 15:00:00 GMT
ORGANIZATION "Hirschmann Automation and Control GmbH"
CONTACT-INFO
"Customer Support
Postal:
Hirschmann Automation and Control GmbH
Stuttgarter Str. 45-51
72654 Neckartenzlingen
Germany
Tel: +49 7127 14 1981
Web: http://www.hicomcenter.com/
E-Mail: hicomcenter@hirschmann.com"
DESCRIPTION
"The Hirschmann Private IO Module definitions for Platform devices."
-- Revision history.
REVISION
"201011081500Z" -- 08 Nov 2010 15:00:00 GMT
DESCRIPTION
"first release"
::= { hmChassis 13 }
-- *************************************************************************
-- Group Config
-- *************************************************************************
hmIOModuleConfigGroup OBJECT IDENTIFIER
::= { hmIOModuleGroup 1 }
-- *************************************************************************
-- Goup Common Config
-- *************************************************************************
hmIOModConfigCommon OBJECT IDENTIFIER
::= { hmIOModuleConfigGroup 1 }
hmIOModConfigDigInputAdminState OBJECT-TYPE
SYNTAX HmEnabledStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"enables sending SNMP traps or log events on input change.
(if disable(2) input task will do nothing)."
DEFVAL { disable }
::= { hmIOModConfigCommon 1 }
hmIOModConfigDigOutputAdminState OBJECT-TYPE
SYNTAX HmEnabledStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"enables polling of output values (if disable(2) output task will do nothing)."
DEFVAL { disable }
::= { hmIOModConfigCommon 2 }
hmIOModConfigDigInputRefreshInterval OBJECT-TYPE
SYNTAX Integer32 (500..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The refresh interval (in ms) of the input values.
Minimum 500ms, Maximum 10000ms (10s)."
DEFVAL { 1000 }
::= { hmIOModConfigCommon 3 }
hmIOModConfigDigOutputRefreshInterval OBJECT-TYPE
SYNTAX Integer32 (500..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The refresh interval (in ms) of the output values.
Minimum 500ms, Maximum 10000ms (10s)."
DEFVAL { 1000 }
::= { hmIOModConfigCommon 4 }
hmIOModConfigDigOutputRetryCount OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The retry count for the output values.
when after the number of configured retries no SNMP get request
was answered, the output value (hmIOModOutputValue) will be
set to invalid (3). Minimum 1, Maximum 10."
DEFVAL { 3 }
::= { hmIOModConfigCommon 5 }
-- *************************************************************************
-- Table Digital Input Config
-- *************************************************************************
hmIOModConfigDigInputTable OBJECT-TYPE
SYNTAX SEQUENCE OF HmIOModConfigDigInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"IO module config table for inputs"
::= { hmIOModuleConfigGroup 2 }
hmIOModConfigDigInputEntry OBJECT-TYPE
SYNTAX HmIOModConfigDigInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"IO module config entry for inputs"
INDEX {
hmIOModConfigDigInputModID,
hmIOModConfigDigInputID}
::= { hmIOModConfigDigInputTable 1 }
HmIOModConfigDigInputEntry ::= SEQUENCE {
hmIOModConfigDigInputModID Integer32,
hmIOModConfigDigInputID Integer32,
hmIOModConfigDigInputLogEvent HmEnabledStatus,
hmIOModConfigDigInputSnmpTrap HmEnabledStatus
}
hmIOModConfigDigInputModID OBJECT-TYPE
SYNTAX Integer32 (1..7)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The module ID of an input."
::= { hmIOModConfigDigInputEntry 1 }
hmIOModConfigDigInputID OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ID of an input."
::= { hmIOModConfigDigInputEntry 2 }
hmIOModConfigDigInputLogEvent OBJECT-TYPE
SYNTAX HmEnabledStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trigger an event log when input status changes.
If the value is disable (2), no event log entry will be written.
If the value is enable (1), an event log entry will be written when
the input state changes.
The input state will be checked acording to the refresh interval
entered in hmIOModConfigDigInputRefreshInterval."
DEFVAL { disable }
::= { hmIOModConfigDigInputEntry 3 }
hmIOModConfigDigInputSnmpTrap OBJECT-TYPE
SYNTAX HmEnabledStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trigger an SNMP trap log when input status changes.
If the value is disable (2), no SNMP trap will be sent.
If the value is enable (1), a SNMP trap will be sent when
the input state changes.
The SNMP trap will be sent to all receivers configured
in hmAgentSnmpTrapReceiverConfigTable.
The input state will be checked acording to the refresh interval entered
in hmIOModConfigDigInputRefreshInterval."
DEFVAL { disable }
::= { hmIOModConfigDigInputEntry 4 }
-- *************************************************************************
-- Table Digital Output Config
-- *************************************************************************
hmIOModConfigDigOutputTable OBJECT-TYPE
SYNTAX SEQUENCE OF HmIOModConfigDigOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"IO module config table for outputs"
::= { hmIOModuleConfigGroup 3 }
hmIOModConfigDigOutputEntry OBJECT-TYPE
SYNTAX HmIOModConfigDigOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"IO module config entry for outputs"
INDEX {
hmIOModConfigDigOutputModID,
hmIOModConfigDigOutputID }
::= { hmIOModConfigDigOutputTable 1 }
HmIOModConfigDigOutputEntry ::= SEQUENCE {
hmIOModConfigDigOutputModID Integer32,
hmIOModConfigDigOutputID Integer32,
hmIOModConfigDigOutputLogEvent HmEnabledStatus,
hmIOModConfigDigOutputSnmpTrap HmEnabledStatus,
hmIOModConfigDigOutputSourceIP IpAddress,
hmIOModConfigDigOutputSourceModID Integer32,
hmIOModConfigDigOutputSourceID Integer32,
hmIOModConfigDigOutputSourcePort InetPortNumber}
hmIOModConfigDigOutputModID OBJECT-TYPE
SYNTAX Integer32 (1..7)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The module ID of an output."
::= { hmIOModConfigDigOutputEntry 1 }
hmIOModConfigDigOutputID OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ID of an output."
::= { hmIOModConfigDigOutputEntry 2 }
hmIOModConfigDigOutputLogEvent OBJECT-TYPE
SYNTAX HmEnabledStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trigger an event log when output status changes.
If the value is disable (2), no event log entry will be written.
If the value is enable (1), an event log entry will be written when
the output state changes.
The output state will be checked acording to the refresh interval
entered in hmIOModConfigDigOutputRefreshInterval."
DEFVAL { disable }
::= { hmIOModConfigDigOutputEntry 3 }
hmIOModConfigDigOutputSnmpTrap OBJECT-TYPE
SYNTAX HmEnabledStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trigger an SNMP trap log when output status changes.
If the value is disable (2), no SNMP trap will be sent.
If the value is enable (1), a SNMP trap will be sent when
the output state changes.
The SNMP trap will be sent to all receivers configured
in hmAgentSnmpTrapReceiverConfigTable.
The output state will be checked acording to the refresh interval
entered in hmIOModConfigDigOutputRefreshInterval."
DEFVAL { disable }
::= { hmIOModConfigDigOutputEntry 4 }
hmIOModConfigDigOutputSourceIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of an input mirrored to the output.
Use 0.0.0.0 if the output should not be set.
In this case hmIOModOutputValue is invalid (3).
Use 127.0.0.1 if an local input should be used."
DEFVAL { "0.0.0.0" }
::= { hmIOModConfigDigOutputEntry 5 }
hmIOModConfigDigOutputSourceModID OBJECT-TYPE
SYNTAX Integer32 (1..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The module ID of an input mirrored to the output.
Ignored when hmIOModConfigDigOutputSourceIP is 0.0.0.0."
DEFVAL { 1 }
::= { hmIOModConfigDigOutputEntry 6 }
hmIOModConfigDigOutputSourceID OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ID of an input mirrored to the output.
Ignored when hmIOModConfigDigOutputSourceIP is 0.0.0.0."
DEFVAL { 1 }
::= { hmIOModConfigDigOutputEntry 7 }
hmIOModConfigDigOutputSourcePort OBJECT-TYPE
SYNTAX InetPortNumber
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SNMP port number being used by the input mirrored to the output.
This port would be the destination for the SNMP requests for
polling the state of the input."
DEFVAL { 161 }
::= { hmIOModConfigDigOutputEntry 8 }
-- *************************************************************************
-- Group Value
-- *************************************************************************
hmIOModuleValueGroup OBJECT IDENTIFIER
::= { hmIOModuleGroup 2 }
-- *************************************************************************
-- Table Digital Input Value
-- *************************************************************************
hmIOModValueDigInputTable OBJECT-TYPE
SYNTAX SEQUENCE OF HmIOModValueDigInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"IO module value table for inputs"
::= { hmIOModuleValueGroup 1 }
hmIOModValueDigInputEntry OBJECT-TYPE
SYNTAX HmIOModValueDigInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"IO module value entry for inputs"
INDEX {
hmIOModValueDigInputModID,
hmIOModValueDigInputID}
::= { hmIOModValueDigInputTable 1 }
HmIOModValueDigInputEntry ::= SEQUENCE {
hmIOModValueDigInputModID Integer32,
hmIOModValueDigInputID Integer32,
hmIOModValueDigInputValue INTEGER}
hmIOModValueDigInputModID OBJECT-TYPE
SYNTAX Integer32 (1..7)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The module ID of an input."
::= { hmIOModValueDigInputEntry 1 }
hmIOModValueDigInputID OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ID of an input."
::= { hmIOModValueDigInputEntry 2 }
hmIOModValueDigInputValue OBJECT-TYPE
SYNTAX INTEGER {
not-available (0),
high (1),
low (2)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the input.
If the value is not-available(0), then the IO module is not plugged in,
if the value is high(1), the input has high (+24V) value,
if the value is low(2), the input has low (0V) value."
::= { hmIOModValueDigInputEntry 3 }
-- *************************************************************************
-- Table Digital Output Value
-- *************************************************************************
hmIOModValueDigOutputTable OBJECT-TYPE
SYNTAX SEQUENCE OF HmIOModValueDigOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"IO module value table for outputs"
::= { hmIOModuleValueGroup 2 }
hmIOModValueDigOutputEntry OBJECT-TYPE
SYNTAX HmIOModValueDigOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"IO module value entry for outputs"
INDEX {
hmIOModValueDigOutputModID,
hmIOModValueDigOutputID }
::= { hmIOModValueDigOutputTable 1 }
HmIOModValueDigOutputEntry ::= SEQUENCE {
hmIOModValueDigOutputModID Integer32,
hmIOModValueDigOutputID Integer32,
hmIOModValueDigOutputValue INTEGER}
hmIOModValueDigOutputModID OBJECT-TYPE
SYNTAX Integer32 (1..7)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The module ID of an Output."
::= { hmIOModValueDigOutputEntry 1 }
hmIOModValueDigOutputID OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ID of an Output."
::= { hmIOModValueDigOutputEntry 2 }
hmIOModValueDigOutputValue OBJECT-TYPE
SYNTAX INTEGER {
not-available (0),
high (1),
low (2),
invalid (3),
not-configured (4)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Status of the output.
If the value is not-available(0), then the IO module is not plugged in,
if the value is high(1), the output has high (+24V) value,
if the value is low(2), the output has low (0V) value.
If the value is invalid (3), the output has low (0V) value and
the IO input source is configured but can not be read.
If the value is not-configured (4), the output has low (0V) value and
has no IO input source configured."
::= { hmIOModValueDigOutputEntry 3 }
-- *************************************************************************
-- TRAP's
-- *************************************************************************
hmIOModDigInputChangeTrap NOTIFICATION-TYPE
OBJECTS {
hmIOModValueDigInputValue}
STATUS current
DESCRIPTION
"This trap is sent if the state of an input changes.
This trap is sent only when hmIOModConfigDigInputSnmpTrap is set
to enabled (1)."
::= { hmChassisEvent 16 }
hmIOModDigOutputChangeTrap NOTIFICATION-TYPE
OBJECTS {
hmIOModValueDigOutputValue}
STATUS current
DESCRIPTION
"This trap is sent if the state of an input changes.
This trap is sent when hmIOModConfigDigOutputSnmpTrap is set
to enabled (1) or when the output value changes from or to invalid (3)"
::= { hmChassisEvent 17 }
END