566 lines
19 KiB
Plaintext
566 lines
19 KiB
Plaintext
|
|
HM2-POE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
--
|
|
-- *************************************************************
|
|
-- Hirschmann Power over Ethernet Management MIB
|
|
-- *************************************************************
|
|
--
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, NOTIFICATION-TYPE,
|
|
OBJECT-TYPE,
|
|
Integer32 FROM SNMPv2-SMI -- RFC 2578
|
|
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
|
|
hm2IfacePhysIndex FROM HM2-DEVMGMT-MIB
|
|
HmEnabledStatus, HmTimeHHMM24,
|
|
hm2ConfigurationMibs FROM HM2-TC-MIB;
|
|
|
|
hm2PoeMgmtMib MODULE-IDENTITY
|
|
LAST-UPDATED "201110310000Z" -- October 31, 2011
|
|
ORGANIZATION "Hirschmann Automation and Control GmbH"
|
|
CONTACT-INFO
|
|
"Postal: Stuttgarter Str. 45-51
|
|
72654 Neckartenzlingen
|
|
Germany
|
|
Phone: +49 7127 140
|
|
E-mail: hac.support@belden.com"
|
|
DESCRIPTION
|
|
"Hirschmann Power over Ethernet Management MIB. This MIB contains
|
|
the private extensions to the RFC 3621.
|
|
Copyright (C) 2011. All Rights Reserved."
|
|
REVISION "201110310000Z" -- October 31, 2011
|
|
DESCRIPTION
|
|
"Initial version."
|
|
::= { hm2ConfigurationMibs 12 }
|
|
|
|
--
|
|
-- *************************************************************
|
|
-- hm2PoeMgmtMib
|
|
-- *************************************************************
|
|
--
|
|
|
|
hm2PoeMgmtMibNotifications OBJECT IDENTIFIER ::= { hm2PoeMgmtMib 0 }
|
|
hm2PoeMgmtMibObjects OBJECT IDENTIFIER ::= { hm2PoeMgmtMib 1 }
|
|
-- hm2PoeMgmtMibConformance OBJECT IDENTIFIER ::= { hm2PoeMgmtMib 2 }
|
|
|
|
|
|
--
|
|
-- *************************************************************
|
|
-- hm2PoeMgmtMib groups
|
|
-- *************************************************************
|
|
--
|
|
|
|
hm2PoeMgmtGroup OBJECT IDENTIFIER ::= { hm2PoeMgmtMibObjects 1 }
|
|
|
|
|
|
--
|
|
-- *************************************************************
|
|
-- hm2PoeMgmtGlobalGroup
|
|
-- *************************************************************
|
|
--
|
|
|
|
hm2PoeMgmtGlobalGroup OBJECT IDENTIFIER ::= { hm2PoeMgmtGroup 1 }
|
|
|
|
hm2PoeMgmtAdminStatus OBJECT-TYPE
|
|
SYNTAX HmEnabledStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables/disables Power over Ethernet management on this device."
|
|
DEFVAL { enable }
|
|
::= { hm2PoeMgmtGlobalGroup 1 }
|
|
|
|
hm2PoeMgmtReservedPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reserved system power for active Power over Ethernet ports in Watts."
|
|
::= { hm2PoeMgmtGlobalGroup 2 }
|
|
|
|
hm2PoeMgmtDeliveredCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The measured current delivered over Ethernet ports in milliamperes"
|
|
::= { hm2PoeMgmtGlobalGroup 3 }
|
|
|
|
--
|
|
-- *************************************************************
|
|
-- hm2PoeMgmtPsuTable
|
|
-- *************************************************************
|
|
--
|
|
|
|
hm2PoeMgmtPsuTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hm2PoeMgmtPsuEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains objects for each power supply type of
|
|
the device (internal or external power supply)."
|
|
::= { hm2PoeMgmtGroup 2 }
|
|
|
|
hm2PoeMgmtPsuEntry OBJECT-TYPE
|
|
SYNTAX Hm2PoeMgmtPsuEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entries of the hm2PoeMgmtPsuTable."
|
|
INDEX { hm2PoeMgmtModulePowerSource }
|
|
::= { hm2PoeMgmtPsuTable 1 }
|
|
|
|
Hm2PoeMgmtPsuEntry ::= SEQUENCE {
|
|
hm2PoeMgmtPsuPower Integer32,
|
|
hm2PoeMgmtPsuReservedPower Integer32,
|
|
hm2PoeMgmtPsuDeliveredPower Integer32,
|
|
hm2PoeMgmtPsuDeliveredCurrent Integer32
|
|
}
|
|
|
|
hm2PoeMgmtPsuPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The power budget per psu type expressed in Watts. Psu types could
|
|
be internal or external."
|
|
::= { hm2PoeMgmtPsuEntry 1 }
|
|
|
|
hm2PoeMgmtPsuReservedPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The reserved power (depending on actual power classes)
|
|
per psu type expressed in Watts."
|
|
::= { hm2PoeMgmtPsuEntry 2 }
|
|
|
|
hm2PoeMgmtPsuDeliveredPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The measured usage power per psu type expressed in Watts."
|
|
::= { hm2PoeMgmtPsuEntry 3 }
|
|
|
|
hm2PoeMgmtPsuDeliveredCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The measured current delivered per psu type expressed in milliamperes"
|
|
::= { hm2PoeMgmtPsuEntry 4 }
|
|
|
|
--
|
|
-- *************************************************************
|
|
-- hm2PoeMgmtPortTable
|
|
-- *************************************************************
|
|
--
|
|
|
|
hm2PoeMgmtPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hm2PoeMgmtPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains objects for each Power over Ethernet interface of
|
|
the device."
|
|
::= { hm2PoeMgmtGroup 3 }
|
|
|
|
hm2PoeMgmtPortEntry OBJECT-TYPE
|
|
SYNTAX Hm2PoeMgmtPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entry of the hm2PoeMgmtPortTable."
|
|
INDEX { hm2IfacePhysIndex }
|
|
::= { hm2PoeMgmtPortTable 1 }
|
|
|
|
Hm2PoeMgmtPortEntry ::= SEQUENCE {
|
|
hm2PoeMgmtPortAdminEnable HmEnabledStatus,
|
|
hm2PoeMgmtPortConsumptionPower Integer32,
|
|
hm2PoeMgmtPortDetectionStatus INTEGER,
|
|
hm2PoeMgmtPortPowerPriority INTEGER,
|
|
hm2PoeMgmtPortPowerClassification INTEGER,
|
|
hm2PoeMgmtPortName SnmpAdminString,
|
|
hm2PoeMgmtPortAllowedClassBits BITS,
|
|
hm2PoeMgmtPortAutoShutdown HmEnabledStatus,
|
|
hm2PoeMgmtPortAutoShutdownTimeStart HmTimeHHMM24,
|
|
hm2PoeMgmtPortAutoShutdownTimeEnd HmTimeHHMM24,
|
|
hm2PoeMgmtPortClassValid INTEGER,
|
|
hm2PoeMgmtPortFastStartup HmEnabledStatus,
|
|
hm2PoeMgmtPortMaxConsumptionPower Integer32,
|
|
hm2PoeMgmtPortPowerLimit Integer32,
|
|
hm2PoeMgmtPortConsumptionCurrent Integer32
|
|
}
|
|
|
|
hm2PoeMgmtPortAdminEnable OBJECT-TYPE
|
|
SYNTAX HmEnabledStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"enable (1) An interface which can provide the PSE functions.
|
|
disable(2) The interface will act - as it would - if it had no PSE
|
|
function."
|
|
DEFVAL { enable }
|
|
::= { hm2PoeMgmtPortEntry 1 }
|
|
|
|
hm2PoeMgmtPortConsumptionPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Measured usage power per interface expressed in Milliwatts."
|
|
::= { hm2PoeMgmtPortEntry 2 }
|
|
|
|
hm2PoeMgmtPortDetectionStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
searching(2),
|
|
deliveringPower(3),
|
|
fault(4),
|
|
test(5),
|
|
otherFault(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the operational status of the port PD detection.
|
|
A value of disabled(1)- indicates that the PSE State diagram
|
|
is in the state DISABLED.
|
|
A value of deliveringPower(3) - indicates that the PSE State
|
|
diagram is in the state POWER_ON.
|
|
A value of fault(4) - indicates that the PSE State diagram is
|
|
in the state TEST_ERROR.
|
|
A value of test(5) - indicates that the PSE State diagram is
|
|
in the state TEST_MODE.
|
|
A value of otherFault(6) - indicates that the PSE State
|
|
diagram is in the state IDLE due to the variable
|
|
error_conditions.
|
|
A value of searching(2)- indicates the PSE State diagram is
|
|
in a state other than those listed above."
|
|
|
|
::= { hm2PoeMgmtPortEntry 3 }
|
|
|
|
hm2PoeMgmtPortPowerPriority OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
critical(1),
|
|
high(2),
|
|
low(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object controls the priority of the port from the point
|
|
of view of a power management algorithm. The priority that
|
|
is set by this variable could be used by a control mechanism
|
|
that prevents over current situations by disconnecting first
|
|
ports with lower power priority. Ports that connect devices
|
|
critical to the operation of the network - like the E911
|
|
telephones ports - should be set to higher priority."
|
|
|
|
DEFVAL { low }
|
|
::= { hm2PoeMgmtPortEntry 4 }
|
|
|
|
hm2PoeMgmtPortPowerClassification OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
class0(1),
|
|
class1(2),
|
|
class2(3),
|
|
class3(4),
|
|
class4(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Classification is a way to tag different terminals on the
|
|
Power over LAN network according to their power consumption.
|
|
Devices such as IP telephones, WLAN access points and others,
|
|
will be classified according to their power requirements.
|
|
|
|
The meaning of the classification labels is defined in the
|
|
IEEE specification.
|
|
|
|
This variable is valid only while a PD is being powered,
|
|
that is, while the attribute hm2PoeMgmtPortDetectionStatus
|
|
is reporting the enumeration deliveringPower."
|
|
DEFVAL { class0 }
|
|
::= { hm2PoeMgmtPortEntry 5 }
|
|
|
|
hm2PoeMgmtPortName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE(1..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A manager will set the value of this variable to indicate
|
|
the type of powered device that is connected to the port.
|
|
The default value supplied by the agent if no value has
|
|
ever been set should be a zero-length octet string."
|
|
DEFVAL { " " }
|
|
::= { hm2PoeMgmtPortEntry 6 }
|
|
|
|
hm2PoeMgmtPortAllowedClassBits OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
class0(0),
|
|
class1(1),
|
|
class2(2),
|
|
class3(3),
|
|
class4(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Bit mask which defines allowed classes per interface."
|
|
DEFVAL { { class0, class1, class2, class3, class4 } }
|
|
::= { hm2PoeMgmtPortEntry 7 }
|
|
|
|
hm2PoeMgmtPortAutoShutdown OBJECT-TYPE
|
|
SYNTAX HmEnabledStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables/disables automatic shutdown functionality per interface."
|
|
DEFVAL { disable }
|
|
::= { hm2PoeMgmtPortEntry 8 }
|
|
|
|
hm2PoeMgmtPortAutoShutdownTimeStart OBJECT-TYPE
|
|
SYNTAX HmTimeHHMM24
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Start time for the automatic shutdown functionality per interface."
|
|
DEFVAL { "00:00" }
|
|
::= { hm2PoeMgmtPortEntry 9 }
|
|
|
|
hm2PoeMgmtPortAutoShutdownTimeEnd OBJECT-TYPE
|
|
SYNTAX HmTimeHHMM24
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"End time for the automatic shutdown functionality per interface."
|
|
DEFVAL { "00:00" }
|
|
::= { hm2PoeMgmtPortEntry 10 }
|
|
|
|
hm2PoeMgmtPortClassValid OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
invalid(0),
|
|
valid(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Evaluates if class represented through pethPsePortPowerClassifications
|
|
is valid or not. Class is valid if PD is delivered with power or in case
|
|
of power exceeding through a connected device."
|
|
::= { hm2PoeMgmtPortEntry 11 }
|
|
|
|
hm2PoeMgmtPortFastStartup OBJECT-TYPE
|
|
SYNTAX HmEnabledStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables/disables Power over Ethernet fast startup mode on given port.
|
|
The default value is 'disable'."
|
|
DEFVAL { disable }
|
|
::= { hm2PoeMgmtPortEntry 12 }
|
|
|
|
hm2PoeMgmtPortMaxConsumptionPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum observed power consumption (hm2PoeMgmtPortMaxConsumptionPower)
|
|
value expressed in milliwatts used by the PD.
|
|
The value is reset to 0 if the PoE admin state is set to disable
|
|
or if a disconnect of the PD is detected."
|
|
::= { hm2PoeMgmtPortEntry 13 }
|
|
|
|
hm2PoeMgmtPortPowerLimit OBJECT-TYPE
|
|
SYNTAX Integer32 (0..30000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The power limit per port expressed in milliwatts. If set to
|
|
zero the power consumption limitation is disabled."
|
|
DEFVAL { 0 }
|
|
::= { hm2PoeMgmtPortEntry 14 }
|
|
|
|
hm2PoeMgmtPortConsumptionCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Measured current consumption per interface expressed in milliamperes (mA)."
|
|
::= { hm2PoeMgmtPortEntry 15 }
|
|
|
|
--
|
|
-- *************************************************************
|
|
-- hm2PoeMgmtModuleTable
|
|
-- *************************************************************
|
|
--
|
|
|
|
hm2PoeMgmtModuleTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hm2PoeMgmtModuleEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains objects for each plugged PoE module of
|
|
the device. If the device is non-modular and supports PoE it
|
|
contains only one entry."
|
|
::= { hm2PoeMgmtGroup 4 }
|
|
|
|
hm2PoeMgmtModuleEntry OBJECT-TYPE
|
|
SYNTAX Hm2PoeMgmtModuleEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entries of the hm2PoeMgmtModuleTable."
|
|
INDEX { hm2PoeMgmtModuleUnitIndex, hm2PoeMgmtModuleSlotIndex }
|
|
::= { hm2PoeMgmtModuleTable 1 }
|
|
|
|
Hm2PoeMgmtModuleEntry ::= SEQUENCE {
|
|
hm2PoeMgmtModuleUnitIndex Integer32,
|
|
hm2PoeMgmtModuleSlotIndex Integer32,
|
|
hm2PoeMgmtModulePower Integer32,
|
|
hm2PoeMgmtModuleMaximumPower Integer32,
|
|
hm2PoeMgmtModuleReservedPower Integer32,
|
|
hm2PoeMgmtModuleDeliveredPower Integer32,
|
|
hm2PoeMgmtModulePowerSource INTEGER,
|
|
hm2PoeMgmtModuleUsageThreshold Integer32,
|
|
hm2PoeMgmtModuleNotificationControlEnable HmEnabledStatus,
|
|
hm2PoeMgmtModuleDeliveredCurrent Integer32
|
|
}
|
|
|
|
hm2PoeMgmtModuleUnitIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unit number - for stacking devices."
|
|
::= { hm2PoeMgmtModuleEntry 1 }
|
|
|
|
hm2PoeMgmtModuleSlotIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Slot number of the plugged PoE module."
|
|
::= { hm2PoeMgmtModuleEntry 2 }
|
|
|
|
hm2PoeMgmtModulePower OBJECT-TYPE
|
|
SYNTAX Integer32 (0..1000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configurable power budget per module expressed in Watts. The default
|
|
value is hm2PoeMgmtModuleMaximumPower and depends on the hardware."
|
|
DEFVAL { 1000 }
|
|
::= { hm2PoeMgmtModuleEntry 3 }
|
|
|
|
hm2PoeMgmtModuleMaximumPower OBJECT-TYPE
|
|
SYNTAX Integer32 (0..1000)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum available power budget per module expressed in Watts. This
|
|
value depends on the device or module."
|
|
::= { hm2PoeMgmtModuleEntry 4 }
|
|
|
|
hm2PoeMgmtModuleReservedPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The reserved power (depending on actual power classes)
|
|
per module expressed in Watts."
|
|
::= { hm2PoeMgmtModuleEntry 5 }
|
|
|
|
hm2PoeMgmtModuleDeliveredPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The measured usage power per module expressed in Watts."
|
|
::= { hm2PoeMgmtModuleEntry 6 }
|
|
|
|
hm2PoeMgmtModulePowerSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
internal(0),
|
|
external(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the type of the PoE power source.
|
|
internal (0) means that the PoE power is used from the internal PSU and
|
|
external (1) means that a external PoE PSU must be installed and connected to this module."
|
|
::= { hm2PoeMgmtModuleEntry 7 }
|
|
|
|
hm2PoeMgmtModuleUsageThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (1..99)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The usage power threshold per module expressed in percent.
|
|
If this threshold is exceeded a alarm is initiated."
|
|
DEFVAL { 90 }
|
|
::= { hm2PoeMgmtModuleEntry 8 }
|
|
|
|
hm2PoeMgmtModuleNotificationControlEnable OBJECT-TYPE
|
|
SYNTAX HmEnabledStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object controls, on a per-module basis, whether
|
|
or not notifications from the agent are enabled. "
|
|
DEFVAL { enable }
|
|
::= { hm2PoeMgmtModuleEntry 9 }
|
|
|
|
hm2PoeMgmtModuleDeliveredCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The measured current consumption per module expressed in milliamperes (mA)."
|
|
::= { hm2PoeMgmtModuleEntry 10 }
|
|
|
|
--
|
|
-- *************************************************************
|
|
-- hm2PoeMgmtMibNotifications
|
|
-- *************************************************************
|
|
--
|
|
|
|
hm2PoeMgmtModulePowerUsageOnNotification NOTIFICATION-TYPE
|
|
OBJECTS { hm2PoeMgmtModuleDeliveredPower }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Notification indicate PSE Threshold usage indication
|
|
is on, the usage power is above the threshold.
|
|
At least 500 msec must elapse between notifications being
|
|
emitted by the same object instance."
|
|
::= { hm2PoeMgmtMibNotifications 1 }
|
|
|
|
hm2PoeMgmtModulePowerUsageOffNotification NOTIFICATION-TYPE
|
|
OBJECTS { hm2PoeMgmtModuleDeliveredPower }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Notification indicate PSE Threshold usage indication
|
|
is on, the usage power is below the threshold.
|
|
At least 500 msec must elapse between notifications being
|
|
emitted by the same object instance."
|
|
::= { hm2PoeMgmtMibNotifications 2 }
|
|
|
|
|
|
hm2PoeMgmtPortMaxConfiguredPowerLimitExceeded NOTIFICATION-TYPE
|
|
OBJECTS { hm2IfacePhysIndex, hm2PoeMgmtPortMaxConsumptionPower, hm2PoeMgmtPortPowerLimit }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap reports an exceeding of the configured power limit.
|
|
This notification indicates that a PD consumes more power
|
|
that the maximum configured on the port and the system reserved
|
|
the maximum power required for the negotiated class."
|
|
::= { hm2PoeMgmtMibNotifications 3 }
|
|
|
|
END
|
|
|