-- Copyright (C) 2005 by H3C TECHNOLOGIES. All rights reserved.
--
-- Description: HGMP Information MIB for LAN Switch
-- Reference:
-- Version: V1.8
-- History:
-- V1.0 2001.5.15 Created Ye dalu
-- V1.1 2004/7/20 Modify Object Name from HwNDPNbEntry
-- to HwNDPPortNbEntry
-- V1.2 2004/8/09 add notification hgmpNetTopChange
-- V1.3 2004-09-24 modify value of STATUS clause from 'mandatory' to 'current' by gaolong
-- V1.4 2004-10-12 updated by gaolong
-- Import NOTIFICATION-TYPE.
-- V1.5 2004-11-02 updated by gaolong
-- Import Counter32.
-- V1.6 2005-12-9 added by zhanglin KF0176
-- add hgmpClusterProtocolMac
-- add hgmpWhitelistNbTable
-- add hgmpWhitelistTable
-- add hgmpBlacklistTable
-- 2005-12-20 added by zushuzhi 03030
-- add hgmpMemberPriPortTable
-- add hgmpNTDPTopLinkStatus
-- V1.7 2006-04-30 modified by gaolong
-- relocate hgmpProtocolMac, hgmpTopologyManagement, hgmpMemberPriPortTable
-- and the objects below them.
-- relocate hgmpNTDPTopLinkStatus in hgmpNTDPTopLinkStatus.
-- V1.8 2006-05-08 modify the description of hgmpNTDPCollectTopTime by shanfeng
-- ==================================================================
-- ==================================================================
--
-- Varibles and types be imported
--
-- ==================================================================
HUAWEI-HGMP-MIB DEFINITIONS ::= BEGIN
IMPORTS
huaweiUtility
FROM HUAWEI-3COM-OID-MIB
IpAddress, Integer32, OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY,
NOTIFICATION-TYPE, Counter32, Unsigned32
FROM SNMPv2-SMI
RowStatus, MacAddress, TEXTUAL-CONVENTION, DisplayString
FROM SNMPv2-TC;
hwCluster MODULE-IDENTITY
LAST-UPDATED "200512061452Z"
ORGANIZATION
"Hangzhou H3C Tech. Co., Ltd."
CONTACT-INFO
"Platform Team Hangzhou H3C Tech. Co., Ltd.
Hai-Dian District Beijing P.R. China
http://www.h3c.com
Zip:100085
"
DESCRIPTION
"This MIB contains objects to manage the hgmp operations,
which are used on lanswitch products."
::= { huaweiUtility 7 }
-- ==================================================================
--
-- ======================= definition begin =========================
--
-- ==================================================================
--
-- cluster definitions
--
hwClusterObject OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This MIB contains objects to manage the cluster operations, which
are used on lanswitch products."
::= { hwCluster 1 }
hgmpSetVLANSecurity OBJECT-TYPE
SYNTAX INTEGER
{
noSecurity(0),
security(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure whether to perform the VLAN check inside the cluster."
DEFVAL { security }
::= { hwClusterObject 1 }
hgmpHandShakeInterval OBJECT-TYPE
SYNTAX Integer32(1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Handshaking interval of the cluster member switches."
DEFVAL { 10 }
::= { hwClusterObject 2 }
hgmpHandShakeHoldtime OBJECT-TYPE
SYNTAX Integer32(1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Holdtime of administrator switch and member switch in the cluster."
DEFVAL { 60 }
::= { hwClusterObject 3 }
hgmpGrpMemberTableChange OBJECT-TYPE
SYNTAX Integer32(0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Add 1 to the member list after it changes. The administrator checks if
the value has changed. If not, he will not read the list once more."
DEFVAL { 0 }
::= { hwClusterObject 4 }
hgmpMemberDisconRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Disconnection times of the member and administrator switches divided by
member number times 1000."
DEFVAL { 0 }
::= { hwClusterObject 5 }
hgmpCmdLanswitchFlag OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Administrator switch flag"
DEFVAL { false }
::= { hwClusterObject 6 }
hgmpCmdClusterName OBJECT-TYPE
SYNTAX OCTET STRING(SIZE (0..8))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Cluster name of the administrator switch"
::= { hwClusterObject 7 }
hgmpMngPriIpSegCMIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The private management IP address of the administrator switch,
which can not be modified after the cluster has been created."
::= { hwClusterObject 8 }
hgmpMngPriIpMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The private management IP address mask assigned by the administrator
switch, which cannot be modified after the cluster has been created."
::= { hwClusterObject 9 }
hgmpFtpServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The cluster members can access the Ftp Server through the administrator
switch, which can only be configured and accessed on the administrator
switch."
::= { hwClusterObject 10 }
hgmpTftpServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The cluster members can access the Tftp Server through the administrator
switch, which can only be configured and accessed on the administrator
switch."
::= { hwClusterObject 11 }
hgmpSnmpHost OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Snmp Host to send the cluster trap packets, which can only be
configured and accessed on the administrator switch."
::= { hwClusterObject 12 }
hgmpLogHost OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Log host of the cluster, which can only be configured and accessed on
the administrator switch."
::= { hwClusterObject 13 }
--
-- TABLE: Group member table
--
hgmpGrpMemberTable OBJECT-TYPE
SYNTAX SEQUENCE OF HgmpGrpMemberEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of cluster member switches"
::= { hwClusterObject 14 }
hgmpGrpMemberEntry OBJECT-TYPE
SYNTAX HgmpGrpMemberEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX
{
hgmpGrpMemberDeviceId
}
::= { hgmpGrpMemberTable 1 }
HgmpGrpMemberEntry ::=
SEQUENCE
{
hgmpGrpMemberDeviceId OCTET STRING,
hgmpGrpMemberSerial Integer32,
hgmpGrpMemberIpAddr IpAddress,
hgmpGrpMemberName OCTET STRING,
hgmpGrpMemberPassword OCTET STRING,
hgmpGrpMemberPlatform OCTET STRING,
hgmpGrpMemberStatus INTEGER,
hgmpGrpMemberDisconCount Integer32,
hgmpGrpMemberEnrollTime Integer32,
hgmpGrpMemberOperate RowStatus
}
hgmpGrpMemberDeviceId OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"4 bytes reserved as 0x0 + 6 bytes of MAC address, expressed as
a character string of the hexadecimal number."
::= { hgmpGrpMemberEntry 1 }
hgmpGrpMemberSerial OBJECT-TYPE
SYNTAX Integer32(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When adding member switch to the cluster, the administrator switch
will assign an unique integer to identify it."
::= { hgmpGrpMemberEntry 2 }
hgmpGrpMemberIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The private IP addresses of the member switches for the communication
inside the cluster."
::= { hgmpGrpMemberEntry 3 }
hgmpGrpMemberName OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hostname of the member switch"
::= { hgmpGrpMemberEntry 4 }
hgmpGrpMemberPassword OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Member password for joining a cluster"
::= { hgmpGrpMemberEntry 5 }
hgmpGrpMemberPlatform OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Set the hardware platform. A null string indicates the information
does not exist in the device adjacency table."
::= { hgmpGrpMemberEntry 6 }
hgmpGrpMemberStatus OBJECT-TYPE
SYNTAX INTEGER
{
normal(0),
fault(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Member status on the administrator switch, use for displaying the
network management status."
DEFVAL { fault }
::= { hgmpGrpMemberEntry 7 }
hgmpGrpMemberDisconCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of inside communication disconnection between the member switch
and the administrator switch."
::= { hgmpGrpMemberEntry 8 }
hgmpGrpMemberEnrollTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enrollment time of the member, measured in seconds."
::= { hgmpGrpMemberEntry 9 }
hgmpGrpMemberOperate OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Operation indication field, indicates the operation of adding/removing
a member by the network management agent."
::= { hgmpGrpMemberEntry 10 }
--
-- TABLE: Member reset table
--
hgmpMemberResetTable OBJECT-TYPE
SYNTAX SEQUENCE OF HgmpMemberResetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Reset a member switch in the cluster."
::= { hwClusterObject 15 }
hgmpMemberResetEntry OBJECT-TYPE
SYNTAX HgmpMemberResetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX
{
hgmpMemberResetMAC
}
::= { hgmpMemberResetTable 1 }
HgmpMemberResetEntry ::=
SEQUENCE
{
hgmpMemberResetMAC OCTET STRING,
hgmpMemberEraseflash INTEGER
}
hgmpMemberResetMAC OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The management MAC address of the switch to be reset, which is the
unique identifier of the switch."
::= { hgmpMemberResetEntry 1 }
hgmpMemberEraseflash OBJECT-TYPE
SYNTAX INTEGER
{
noErase(0),
erase(1),
cannotget(65535)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether to erase the configuration file from the flash after
resetting the switch. Read this node, cannotget(65535) will be
returned."
::= { hgmpMemberResetEntry 2 }
hgmpEventsV2 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Definition point for cluster notifications."
::= { hwClusterObject 0 }
hgmpMemberfailure NOTIFICATION-TYPE
OBJECTS
{
hgmpGrpMemberDeviceId
}
STATUS current
DESCRIPTION
"When a cluster member failure, send a snmp trap to the network
management."
::= { hgmpEventsV2 1 }
hgmpMemberRecover NOTIFICATION-TYPE
OBJECTS
{
hgmpGrpMemberDeviceId
}
STATUS current
DESCRIPTION
"When a cluster member recover, send a snmp trap to the network
management."
::= { hgmpEventsV2 2 }
hgmpMemberStatusChange NOTIFICATION-TYPE
OBJECTS
{
hgmpGrpMemberDeviceId,
hgmpNTDPCacheClusterRole
}
STATUS current
DESCRIPTION
"When a cluster member status change, send a snmp trap to the
network management."
::= { hgmpEventsV2 3 }
hgmpNetTopChange NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"When net topology of this cluster change, send a snmp trap
to the network management."
::= { hgmpEventsV2 4 }
hgmpClusterRole OBJECT-TYPE
SYNTAX INTEGER
{
roleCMDSW(1),
roleMEMBERSW(2),
roleBAKSW(3),
roleCASW(16),
roleUNISW(17)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This switch's role in cluster."
DEFVAL { roleUNISW }
::= { hwClusterObject 16 }
hgmpClusterMaxPoolNum OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Max switch members that the cluster can support(include
administrator switch)."
::= { hwClusterObject 17 }
hgmpClusterCmdSwMac OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MAC address of administrator switch. It will be filled with
zero when not be a member of cluster."
::= { hwClusterObject 18 }
hgmpRun OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable cluster on this switch."
DEFVAL { true }
::= { hwClusterObject 19 }
--
-- cluster protocol MAC
--
hgmpProtocolMac OBJECT IDENTIFIER ::= { hwClusterObject 22 }
hgmpClusterProtocolMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Protocol MAC of HGMP protocol family. All multicast packets of this
protocol family use this MAC as destination MAC."
DEFVAL { '0180C200000A'H }
::= { hgmpProtocolMac 1 }
--
-- hgmp topology management
--
hgmpTopologyManagement OBJECT IDENTIFIER ::= { hwClusterObject 23 }
--
-- TABLE: Whitelist Table
--
hgmpWhitelistTable OBJECT-TYPE
SYNTAX SEQUENCE OF HgmpWhitelistEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cluster switches white list table. White list topology is the
topology which has been affirmed by network administrator in a
cluster, and all devices in white list topology are recorded in this
table. Against to white list table, black list table records the
devices which are denied to join in cluster. Adding a black list
device to white list table will cause a failure."
::= { hgmpTopologyManagement 1 }
hgmpWhitelistEntry OBJECT-TYPE
SYNTAX HgmpWhitelistEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry items"
INDEX
{
hgmpWhitelistDeviceId
}
::= { hgmpWhitelistTable 1 }
HgmpWhitelistEntry ::=
SEQUENCE
{
hgmpWhitelistDeviceId OCTET STRING,
hgmpWhitelistSerial Integer32,
hgmpWhitelistRowStatus RowStatus
}
hgmpWhitelistDeviceId OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(10))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique identifier indicating a white list switch. Value format of the
this object is 'XXXXYYYYYY', in which 'XXXX' is reserved as 4 bytes of
0x0, 'YYYYYY' is a MAC address.
For example, if the MAC is 000f-e459-000a, the value of this object is
an octet string: '00' '00' '00' '00' '00' '0f' 'e4' '59' '00' '0a'."
::= { hgmpWhitelistEntry 1 }
hgmpWhitelistSerial OBJECT-TYPE
SYNTAX Integer32(0..2047 | 65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When adding member switch to the cluster, the administrator switch
will assign an unique integer to identify it. 0xffff means invalid
value for this object."
::= { hgmpWhitelistEntry 2 }
hgmpWhitelistRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status of this table."
::= { hgmpWhitelistEntry 3 }
--
-- TABLE: Whitelist neighbor table
--
hgmpWhitelistNbTable OBJECT-TYPE
SYNTAX SEQUENCE OF HgmpWhitelistNbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cluster switches white list neighboring information table. White
list neighbor table records all neighbor devices for every white
list device. In fact, white list neighbor table displays the whole
white list topology."
::= { hgmpTopologyManagement 2 }
hgmpWhitelistNbEntry OBJECT-TYPE
SYNTAX HgmpWhitelistNbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry items"
INDEX
{
hgmpWhitelistDeviceId,
hgmpWhitelistNbIndex
}
::= { hgmpWhitelistNbTable 1 }
HgmpWhitelistNbEntry ::=
SEQUENCE
{
hgmpWhitelistNbIndex Integer32,
hgmpWhitelistNbDeviceId OCTET STRING,
hgmpWhitelistPortName OCTET STRING,
hgmpWhitelistNbPortName OCTET STRING
}
hgmpWhitelistNbIndex OBJECT-TYPE
SYNTAX Integer32(1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of a switch which is the neighbor of a white list switch
identified by 'hgmpWhitelistDeviceId'."
::= { hgmpWhitelistNbEntry 1 }
hgmpWhitelistNbDeviceId OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique identifier indicating a neighbor switch of a white list
switch. Value format of the this object is 'XXXXYYYYYY', in which
'XXXX' is reserved as 4 bytes of 0x0, 'YYYYYY' is a MAC address.
For example, if the MAC is 000f-e459-000a, the value of this object
is an octet string: '00' '00' '00' '00' '00' '0f' 'e4' '59' '00' '0a'."
::= { hgmpWhitelistNbEntry 2 }
hgmpWhitelistPortName OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..47))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the port which a white list switch connects to the
neighbor specified by 'hgmpWhitelistNbIndex'."
::= { hgmpWhitelistNbEntry 3 }
hgmpWhitelistNbPortName OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..47))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the port which a neighbor device connects to the white
list switch specified by 'hgmpWhitelistDeviceId'."
::= { hgmpWhitelistNbEntry 4 }
--
-- TABLE: Blacklist table
--
hgmpBlacklistTable OBJECT-TYPE
SYNTAX SEQUENCE OF HgmpBlacklistEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cluster switches black list table. The black list table records all
black list devices, and a device in black list is not permitted to
join in any cluster."
::= { hgmpTopologyManagement 3 }
hgmpBlacklistEntry OBJECT-TYPE
SYNTAX HgmpBlacklistEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry items"
INDEX
{
hgmpBlacklistDeviceId
}
::= { hgmpBlacklistTable 1 }
HgmpBlacklistEntry ::=
SEQUENCE
{
hgmpBlacklistDeviceId OCTET STRING,
hgmpBlacklistAccessDeviceId OCTET STRING,
hgmpBlacklistAccessPortName OCTET STRING,
hgmpBlacklistRowStatus RowStatus
}
hgmpBlacklistDeviceId OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(10))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique identifier indicating a black list switch. Value format of the
this object is 'XXXXYYYYYY', in which 'XXXX' is reserved as 4 bytes
of 0x0, 'YYYYYY' is a MAC address.
For example, if the MAC is 000f-e459-000a, the value of this object is
an octet string: '00' '00' '00' '00' '00' '0f' 'e4' '59' '00' '0a'."
::= { hgmpBlacklistEntry 1 }
hgmpBlacklistAccessDeviceId OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique identifier indicating the access device of a black list switch.
Tracing from a black list device to the cluster commander switch, the
device which the black list switch directly connects to is the access
device.
Value format of the this object is 'XXXXYYYYYY', in which 'XXXX' is
reserved as 4 bytes of 0x0, 'YYYYYY' is a MAC address. 10 bytes of 0xff
means invalid value for this object.
For example, if the MAC is 000f-e459-000a, the value of this object is
an octet string: '00' '00' '00' '00' '00' '0f' 'e4' '59' '00' '0a'."
::= { hgmpBlacklistEntry 2 }
hgmpBlacklistAccessPortName OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..47))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port which the access device connecting to the black list switch
is named access port, the object returns the access port name.
An empty string means invalid value for this object."
::= { hgmpBlacklistEntry 3 }
hgmpBlacklistRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status of this table."
::= { hgmpBlacklistEntry 4 }
--
-- TABLE: Member private port number table
--
hgmpMemberPriPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF HgmpMemberPriPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains port number for different network protocols
on each member switch. The port number can be used to access
a specified member switch with specified protocol and private
IP address."
::= { hwClusterObject 24 }
hgmpMemberPriPortEntry OBJECT-TYPE
SYNTAX HgmpMemberPriPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a specified member private port entry. The
indexes of the entry are hgmpGrpMemberDevId and
hgmpMemberPriPortProto, which indicate entries in the table."
INDEX
{
hgmpMemberDevId,
hgmpMemberPriPortProto
}
::= { hgmpMemberPriPortTable 1 }
HgmpMemberPriPortEntry ::=
SEQUENCE
{
hgmpMemberDevId OCTET STRING,
hgmpMemberPriPortProto Unsigned32,
hgmpMemberPriPortProtoDescr DisplayString,
hgmpMemberPriPortNum Unsigned32
}
hgmpMemberDevId OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique identifier indicating the switch in cluster.
Value format of the this object is 'XXXXYYYYYY', in which 'XXXX' is
is reserved as 4 bytes of 0x0, 'YYYYYY' is a MAC address."
::= { hgmpMemberPriPortEntry 1 }
hgmpMemberPriPortProto OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of this table. Each instance value of this object
corresponds to a different protocol."
::= { hgmpMemberPriPortEntry 2 }
hgmpMemberPriPortProtoDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It describes the hgmpMemberPriPortProtocol object value.
For example, it is 'SNMP' when hgmpMemberPriPortProtocol value
is 1."
::= { hgmpMemberPriPortEntry 3 }
hgmpMemberPriPortNum OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The private port number of member switch, used by specified
hgmpMemberPriPortProto. By using the private IP address,
specified protocol and port number, other devices outside
cluster can access member switch. The private IP address
can be acquired by reading hgmpGrpMemberIpAddr."
::= { hgmpMemberPriPortEntry 4 }
--
-- stack definitions
--
hwStackObject OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This MIB contains objects to manage the stack operations, which is
used on lanswitch products."
::= { hwCluster 2 }
hgmpStackMemberTableChange OBJECT-TYPE
SYNTAX Integer32(0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Change identifier of the stack member table."
DEFVAL { 0 }
::= { hwStackObject 1 }
hgmpStackMemberDisconRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Disconnection rate of the stack member switches."
DEFVAL { 0 }
::= { hwStackObject 2 }
hgmpMainLanswitchFlag OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of the local switch in the stack."
DEFVAL { false }
::= { hwStackObject 3 }
hgmpStackIpPoolStartIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The first address of the management IP network segment assigned by
the master switch, which cannot be modified in the case that there
is IP address assignment."
::= { hwStackObject 4 }
hgmpStackIpPoolLength OBJECT-TYPE
SYNTAX INTEGER(1..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The length of the management IP segment assigned by the master
switch, which cannot be modified in the case that there is IP
address assignment."
::= { hwStackObject 5 }
hgmpStackIpPoolMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The mask of the management IP segment assigned by the master switch,
which cannot be modified in the case that there is IP address assignment."
DEFVAL { 'FFFF0000'H }
::= { hwStackObject 10 }
--
-- TABLE: Stack member table
--
hgmpStackMemberTable OBJECT-TYPE
SYNTAX SEQUENCE OF HgmpStackMemberEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Stack member table."
::= { hwStackObject 6 }
hgmpStackMemberEntry OBJECT-TYPE
SYNTAX HgmpStackMemberEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX
{
hgmpStackMemberDeviceId
}
::= { hgmpStackMemberTable 1 }
HgmpStackMemberEntry ::=
SEQUENCE
{
hgmpStackMemberDeviceId OCTET STRING,
hgmpStackMemberSerial Integer32,
hgmpStackMemberIpAddr IpAddress,
hgmpStackMemberName OCTET STRING,
hgmpStackMemberPassword OCTET STRING,
hgmpStackMemberPlatform OCTET STRING,
hgmpStackMemberStatus INTEGER,
hgmpStackMemberDisconCount Integer32,
hgmpStackMemberEnrollTime Integer32
}
hgmpStackMemberDeviceId OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"2 bytes address type of the switch + 2 bytes zero + MAC address,
expressed as a hexadecimal number string."
::= { hgmpStackMemberEntry 1 }
hgmpStackMemberSerial OBJECT-TYPE
SYNTAX Integer32(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When adding a member switch to the stack, the master switch will
assign an unique integer to identify it."
::= { hgmpStackMemberEntry 2 }
hgmpStackMemberIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The private member IP address for the communication inside the stack."
::= { hgmpStackMemberEntry 3 }
hgmpStackMemberName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hostname of the member switch."
::= { hgmpStackMemberEntry 4 }
hgmpStackMemberPassword OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Member password for joining a stack."
::= { hgmpStackMemberEntry 5 }
hgmpStackMemberPlatform OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Set the hardware platform. A null string indicates the information
does not exist in the device adjacency table."
::= { hgmpStackMemberEntry 6 }
hgmpStackMemberStatus OBJECT-TYPE
SYNTAX INTEGER
{
normal(0),
fault(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Member status on the master switch, use for displaying the network
management status."
DEFVAL { fault }
::= { hgmpStackMemberEntry 7 }
hgmpStackMemberDisconCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of inside communication disconnection between the member switch
and the master switch."
::= { hgmpStackMemberEntry 8 }
hgmpStackMemberEnrollTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enrollment time of the member, measured in seconds."
::= { hgmpStackMemberEntry 9 }
hgmpStackRole OBJECT-TYPE
SYNTAX INTEGER
{
roleCMDSW(1),
roleMEMBERSW(2),
roleBAKSW(3),
roleCASW(16),
roleUNISW(17)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This switch's role status in stack."
DEFVAL { roleUNISW }
::= { hwStackObject 7 }
hgmpStackMaxPoolNum OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Max switch members in one stack that the switch support (include
main switch)."
::= { hwStackObject 8 }
hgmpStackMainSwMac OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MAC address of main switch. It will be 00.00.00 when not be a
member of stack."
::= { hwStackObject 9 }
--
-- Neighbor protocol objects
--
hwNDPObject OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This MIB contains objects to manage the ndp operations, which are
used on lanswitch products."
::= { hwCluster 5 }
hwNDPStatus OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"NDP protocol module enable flag"
DEFVAL { enable }
::= { hwNDPObject 1 }
hwNDPHelloTimer OBJECT-TYPE
SYNTAX Integer32 (5..254)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"NDP packet transmission interval, measured in seconds."
DEFVAL { 60 }
::= { hwNDPObject 2 }
hwNDPAgingTime OBJECT-TYPE
SYNTAX Integer32(5..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"How long the NDP information of the local switch can be hold in
the adjacent switch, measured in seconds."
DEFVAL { 180 }
::= { hwNDPObject 3 }
hwNDPChange OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Change identifier of the Neighbor table"
DEFVAL { 0 }
::= { hwNDPObject 4 }
hwNDPPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwNDPPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configure to enable/disable the interface NDP of the switch."
::= { hwNDPObject 5 }
hwNDPPortEntry OBJECT-TYPE
SYNTAX HwNDPPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX
{
hwNDPIfIndex
}
::= { hwNDPPortTable 1 }
HwNDPPortEntry ::=
SEQUENCE
{
hwNDPIfIndex Integer32,
hwNDPPortStatus INTEGER
}
hwNDPIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique identifier of an interface of the device."
::= { hwNDPPortEntry 1 }
hwNDPPortStatus OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If it is enable, the device will send and receive the NDP
packets via the interface. To disable the NDP function on the
interface, set the entry as false."
DEFVAL { enable }
::= { hwNDPPortEntry 2 }
hwNDPPortNbTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwNDPPortNbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"NDP neighbor information on the switch."
::= { hwNDPObject 6 }
hwNDPPortNbEntry OBJECT-TYPE
SYNTAX HwNDPPortNbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX
{
hwNDPIfIndex,
hwNDPPortNbDeviceId,
hwNDPPortNbPortName
}
::= { hwNDPPortNbTable 1 }
HwNDPPortNbEntry ::=
SEQUENCE
{
hwNDPPortNbDeviceId OCTET STRING,
hwNDPPortNbPortName OCTET STRING,
hwNDPPortNbDeviceName OCTET STRING,
hwNDPPortNbPortMode INTEGER,
hwNDPPortNbProductVer OCTET STRING,
hwNDPPortNbHardVer OCTET STRING,
hwNDPPortNbBootromVer OCTET STRING,
hwNDPPortNbSoftVer OCTET STRING,
hwNDPPortNbAgingtime Integer32
}
hwNDPPortNbDeviceId OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"2 bytes address type of the member switch + 2 bytes zero + MAC
address, expressed as a character string of the hexadecimal
number."
::= { hwNDPPortNbEntry 1 }
hwNDPPortNbPortName OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..47))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique identifier of a port. A null string indicates that the
field was not included in in the latest NDP packet. Interface
type + card number / slot number / sequence number."
::= { hwNDPPortNbEntry 2 }
hwNDPPortNbDeviceName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Device name. A null string indicates that the field was not
included in the latest NDP packet."
::= { hwNDPPortNbEntry 3 }
hwNDPPortNbPortMode OBJECT-TYPE
SYNTAX INTEGER
{
full(1),
half(2),
auto(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The neighbor port duplex mode."
::= { hwNDPPortNbEntry 4 }
hwNDPPortNbProductVer OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Product version. A null string indicates that the field was
not included in the latest NDP packet."
::= { hwNDPPortNbEntry 5 }
hwNDPPortNbHardVer OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hardware version. A null string indicates that the field was
not included in the latest NDP packet."
::= { hwNDPPortNbEntry 6 }
hwNDPPortNbBootromVer OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bootrom version. A null string indicates that the field was
not included in the latest NDP packet."
::= { hwNDPPortNbEntry 7 }
hwNDPPortNbSoftVer OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Software version. A null string indicates that the field was
not included in the latest NDP packet."
::= { hwNDPPortNbEntry 8 }
hwNDPPortNbAgingtime OBJECT-TYPE
SYNTAX Integer32 (5..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"How long the NDP information of the local switch can be hold
in the adjacent switch, measured in seconds."
::= { hwNDPPortNbEntry 9 }
--
-- NTDP management objects
--
hwNTDPObject OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This MIB contains objects to manage the ntdp operations, which
are used on lanswitch products."
::= { hwCluster 4 }
hgmpNTDPCollectTopTime OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Topology collection interval of the administrator switch of
the cluster, measured in minutes."
DEFVAL { 0 }
::= { hwNTDPObject 1 }
hgmpNTDPHopRange OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Range of the topology collection of the administrator switch"
DEFVAL { 3 }
::= { hwNTDPObject 2 }
hgmpNTDPRun OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable the NTDP function on the switch."
DEFVAL { true }
::= { hwNTDPObject 3 }
hgmpNTDPPortDelay OBJECT-TYPE
SYNTAX Integer32 (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the delay to forward the topology request via the ports,
measured in milliseconds."
DEFVAL { 20 }
::= { hwNTDPObject 4 }
hgmpNTDPHopDelay OBJECT-TYPE
SYNTAX Integer32 (1..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the delay to forward the topology request from every hop,
measured in milliseconds."
DEFVAL { 200 }
::= { hwNTDPObject 5 }
hgmpNTDPLastTopCollectDuration OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Duration of the latest overall topology collection, a
performance count measured in seconds."
DEFVAL { 0 }
::= { hwNTDPObject 6 }
hgmpNTDPCacheChange OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Add 1 when the device table changes. The network administrator
will check if it has changed before accessing the table. If it
has not changed, he will not access again."
DEFVAL { 0 }
::= { hwNTDPObject 7 }
hgmpNTDPTOPTableChange OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Add 1 when the topology table changes. The network
administrator will check if it has changed before accessing
the table. If it has not changed, he will not access again."
DEFVAL { 0 }
::= { hwNTDPObject 8 }
hgmpNTDPInterfaceTable OBJECT-TYPE
SYNTAX SEQUENCE OF HgmpNTDPInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Enable/Disable the NTDP on the switch port."
::= { hwNTDPObject 9 }
hgmpNTDPInterfaceEntry OBJECT-TYPE
SYNTAX HgmpNTDPInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX
{
hgmpNTDPInterfaceIfIndex
}
::= { hgmpNTDPInterfaceTable 1 }
HgmpNTDPInterfaceEntry ::=
SEQUENCE
{
hgmpNTDPInterfaceIfIndex Integer32,
hgmpNTDPInterfaceEnable INTEGER
}
hgmpNTDPInterfaceIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique identifier an interface of the device."
::= { hgmpNTDPInterfaceEntry 1 }
hgmpNTDPInterfaceEnable OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If it is true, the device will send and receive the NTDP
packets via the interface. To disable the NTDP function on the
interface, set the entry as false."
DEFVAL { true }
::= { hgmpNTDPInterfaceEntry 2 }
hgmpNTDPCacheTable OBJECT-TYPE
SYNTAX SEQUENCE OF HgmpNTDPCacheEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Access the information about the switch from the topology table."
::= { hwNTDPObject 10 }
hgmpNTDPCacheEntry OBJECT-TYPE
SYNTAX HgmpNTDPCacheEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX
{
hgmpNTDPCacheHashIndex,
hgmpNTDPCacheDeviceID
}
::= { hgmpNTDPCacheTable 1 }
HgmpNTDPCacheEntry ::=
SEQUENCE
{
hgmpNTDPCacheHashIndex Integer32,
hgmpNTDPCacheDeviceID OCTET STRING,
hgmpNTDPCacheClusterName OCTET STRING,
hgmpNTDPCacheClusterRole INTEGER,
hgmpNTDPCacheCapabilities INTEGER,
hgmpNTDPCacheVersion OCTET STRING,
hgmpNTDPCachePlatform OCTET STRING,
hgmpNTDPCacheMngVLAN INTEGER,
hgmpNTDPCacheHop INTEGER
}
hgmpNTDPCacheHashIndex OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Our NTDP information is saved in the HASH table on the
administrator switch. Using DeviceID as index will lead to the
comparison of a large amount of character strings, which puts
too many burdens on the administrator switch. A HAHSIndex is
added to reduce the character string comparison to the
least range."
::= { hgmpNTDPCacheEntry 1 }
hgmpNTDPCacheDeviceID OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"2 bytes address type of the member switch + 2 bytes zero + MAC
address, expressed as a character string of the
hexadecimal number."
::= { hgmpNTDPCacheEntry 2 }
hgmpNTDPCacheClusterName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the cluster including the device."
::= { hgmpNTDPCacheEntry 3 }
hgmpNTDPCacheClusterRole OBJECT-TYPE
SYNTAX INTEGER
{
roleCOSW(1),
roleMSW(2),
roleBKSW(3),
roleCASW(16),
roleUNISW(17)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cluster role of the current device, which can be a
administrator switch (0x01), member switch(0x02), backup
switch(0x03), candidate switch(0x10) or an independent
switch (incapable of cluster member) (0x11)."
DEFVAL { 17 }
::= { hgmpNTDPCacheEntry 4 }
hgmpNTDPCacheCapabilities OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The capabilities of the device. FF indicates that the field
was not included in in the latest NTDP packet."
DEFVAL { 255 }
::= { hgmpNTDPCacheEntry 5 }
hgmpNTDPCacheVersion OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version information of the corresponding device. A null
string indicates that the field was not included in in the
latest NTDP packet."
::= { hgmpNTDPCacheEntry 6 }
hgmpNTDPCachePlatform OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hardware platform. A null string indicates that the field
was not included in the latest NTDP packet."
::= { hgmpNTDPCacheEntry 7 }
hgmpNTDPCacheMngVLAN OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The management VLAN ID of the device."
DEFVAL { 1 }
::= { hgmpNTDPCacheEntry 8 }
hgmpNTDPCacheHop OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hops to this switch."
::= { hgmpNTDPCacheEntry 9 }
hgmpNTDPTopTable OBJECT-TYPE
SYNTAX SEQUENCE OF HgmpNTDPTopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Access the topology structure collected by the NTDP."
::= { hwNTDPObject 11 }
hgmpNTDPTopEntry OBJECT-TYPE
SYNTAX HgmpNTDPTopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX
{
hgmpNTDPTopHashIndex,
hgmpNTDPTopEdgeStartDevID,
hgmpNTDPTopEdgeIndex
}
::= { hgmpNTDPTopTable 1 }
HgmpNTDPTopEntry ::=
SEQUENCE
{
hgmpNTDPTopHashIndex Integer32,
hgmpNTDPTopEdgeStartDevID OCTET STRING,
hgmpNTDPTopEdgeIndex Integer32,
hgmpNTDPTopEdgeEndDevID OCTET STRING,
hgmpNTDPTopEdgeStartPort OCTET STRING,
hgmpNTDPTopEdgeStartPortFullDuplex INTEGER,
hgmpNTDPTopEdgeStartPortSpeed Integer32,
hgmpNTDPTopEdgeEndPort OCTET STRING,
hgmpNTDPTopLinkStatus INTEGER
}
hgmpNTDPTopHashIndex OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Our NTDP information is saved in the HASH table on the
administrator switch. Using DeviceID as index will lead to the
comparison of a large amount of character strings, which puts
too many burdens on the administrator switch. A HAHSIndex is
added to reduce the character string comparison to the
least range."
::= { hgmpNTDPTopEntry 1 }
hgmpNTDPTopEdgeStartDevID OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"2 bytes address type of the member switch + 2 bytes zero + MAC
address, expressed as a character string of the hexadecimal number."
::= { hgmpNTDPTopEntry 2 }
hgmpNTDPTopEdgeIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Edge index of this entry in the data structure."
::= { hgmpNTDPTopEntry 3 }
hgmpNTDPTopEdgeEndDevID OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"2 bytes address type of the member switch + 2 bytes zero + MAC
address, expressed as a character string of the hexadecimal number."
::= { hgmpNTDPTopEntry 4 }
hgmpNTDPTopEdgeStartPort OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..47))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the first port of a topology edge. Interface
type + card number / slot number / sequence number."
::= { hgmpNTDPTopEntry 5 }
hgmpNTDPTopEdgeStartPortFullDuplex OBJECT-TYPE
SYNTAX INTEGER
{
half(0),
full(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The full-duplex status of the first port on a topology edge."
DEFVAL { half }
::= { hgmpNTDPTopEntry 6 }
hgmpNTDPTopEdgeStartPortSpeed OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The speed of the first port on a topology edge."
DEFVAL { 0 }
::= { hgmpNTDPTopEntry 7 }
hgmpNTDPTopEdgeEndPort OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..47))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the last port of a topology edge. Interface
type + card number / slot number / sequence number."
::= { hgmpNTDPTopEntry 8 }
hgmpNTDPTopLinkStatus OBJECT-TYPE
SYNTAX INTEGER
{
forwarding(1),
blocking(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"In STP or RSTP, it describes link status according to port STP
steady status. In MSTP it describes STP steady status of the
instance which management VLAN belongs to. Either
'hgmpNTDPTopEdgeStartPort' or 'hgmpNTDPTopEdgeEndPort' STP
steady status is 'blocking', this object is 'blocking',
otherwise is 'forwarding'.
If STP or MSTP is disabled, this object is 'forwarding'."
::= { hgmpNTDPTopEntry 11 }
hgmpStackEventsV2 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Definition point for Stack notifications."
::= { hwStackObject 0 }
hgmpStackMemberfailure NOTIFICATION-TYPE
OBJECTS
{
hgmpStackMemberDeviceId
}
STATUS current
DESCRIPTION
"When a stack member failure, send a snmp trap to the network
management."
::= { hgmpStackEventsV2 1 }
hgmpStackMemberRecover NOTIFICATION-TYPE
OBJECTS
{
hgmpStackMemberDeviceId
}
STATUS current
DESCRIPTION
"When a stack member Recover, send a snmp trap to the network
management."
::= { hgmpStackEventsV2 2 }
hgmpStackMemberStatusChange NOTIFICATION-TYPE
OBJECTS
{
hgmpStackMemberDeviceId,
hgmpNTDPCacheClusterRole
}
STATUS current
DESCRIPTION
"When a stack member status change, send a snmp trap to the network
management."
::= { hgmpStackEventsV2 3 }
END