Observium_CE/mibs/ekinops/EKINOPS-PmOa-MIB

2938 lines
78 KiB
Plaintext
Raw Blame History

-- *****************************************************************
-- EKINOPS-pmoa.TXT: MIB
--
--MIB Part Number:3MI00200AJAD
--MIB Version:01
--
-- Copyright (c) 2016 by Ekinops
-- All rights reserved.
--
-- *****************************************************************
EKINOPS-PmOa-MIB DEFINITIONS ::= BEGIN
IMPORTS
ekinops,
EkiState,
EkiOnOff,
EkiMode,
EkiProtocol,
EkiApiState,
EkiSynchroMode,
EkiMeasureType
FROM EKINOPS-MIB
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
Unsigned32,
Integer32,
Counter32,
IpAddress
FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
DisplayString
FROM SNMPv2-TC;
modulepmoa MODULE-IDENTITY
LAST-UPDATED "201605230000Z"
ORGANIZATION "Ekinops"
CONTACT-INFO
"Ekinops
3, rue Blaise Pascal
F-22300 Lannion / FRANCE
Tel : +33 (0)2 96 05 00 30
Fax : +33 (0)2 96 48 62 39
E-mail: support@ekinops.net"
DESCRIPTION
"MIB for the Ekinops pmoa hardware."
REVISION "200601050000Z"
DESCRIPTION
"Initial Version."
REVISION "200711210000Z"
DESCRIPTION
"UPdate Ekinops address, Helps on objects, Ports labels"
REVISION "200902050000Z"
DESCRIPTION
"Add ext Pumps features"
REVISION "200904080000Z"
DESCRIPTION
"Cosmetic for mib compilers"
REVISION "200909140000Z"
DESCRIPTION
"CondType parameters insertion"
REVISION "200912140000Z"
DESCRIPTION
"Correction on traps"
REVISION "201002240000Z"
DESCRIPTION
"Probcause,AlarmType - NMS"
REVISION "201007150000Z"
DESCRIPTION
"Add inventory objet for the NMS"
REVISION "201010290000Z"
DESCRIPTION
"Formula in comments, Objects removal"
REVISION "201011030000Z"
DESCRIPTION
"Modify inventory objet for the NMS"
REVISION "201207040000Z"
DESCRIPTION
"Minor cosmetic updates"
REVISION "201210050000Z"
DESCRIPTION
"Minor labels changes"
REVISION "201403260000Z"
DESCRIPTION
"Probcause,AlarmType - NMS completion"
REVISION "201411240000Z"
DESCRIPTION
"Labels cosmetic updates"
REVISION "201605230000Z"
DESCRIPTION
"New AlarmType <20> synthesisAlarm (12)"
::= { ekinops 9 }
--- *****************************************************
--- LEAF LEVEL 2
--- *****************************************************
pmoaalarms OBJECT IDENTIFIER ::= { modulepmoa 2 }
pmoaAlmOther OBJECT IDENTIFIER ::= { pmoaalarms 1 }
pmoaAlmOtherNurg OBJECT IDENTIFIER ::= { pmoaAlmOther 1 }
pmoaAlmOtherUrg OBJECT IDENTIFIER ::= { pmoaAlmOther 2 }
pmoaAlmOtherCrit OBJECT IDENTIFIER ::= { pmoaAlmOther 3 }
pmoaAlmClient OBJECT IDENTIFIER ::= { pmoaalarms 2 }
pmoaAlmClientNurg OBJECT IDENTIFIER ::= { pmoaAlmClient 1 }
pmoaAlmClientUrg OBJECT IDENTIFIER ::= { pmoaAlmClient 2 }
pmoaAlmClientCrit OBJECT IDENTIFIER ::= { pmoaAlmClient 3 }
pmoaAlmLine OBJECT IDENTIFIER ::= { pmoaalarms 3 }
pmoaAlmLineNurg OBJECT IDENTIFIER ::= { pmoaAlmLine 1 }
pmoaAlmLineUrg OBJECT IDENTIFIER ::= { pmoaAlmLine 2 }
pmoaAlmLineCrit OBJECT IDENTIFIER ::= { pmoaAlmLine 3 }
pmoameasures OBJECT IDENTIFIER ::= { modulepmoa 3 }
pmoaMesrOther OBJECT IDENTIFIER ::= { pmoameasures 1 }
pmoaMesrClient OBJECT IDENTIFIER ::= { pmoameasures 2 }
pmoaMesrLine OBJECT IDENTIFIER ::= { pmoameasures 3 }
pmoacontrolsWrite OBJECT IDENTIFIER ::= { modulepmoa 6 }
pmoaCtrlOther OBJECT IDENTIFIER ::= { pmoacontrolsWrite 1 }
pmoaCtrlClient OBJECT IDENTIFIER ::= { pmoacontrolsWrite 2 }
pmoaCtrlLine OBJECT IDENTIFIER ::= { pmoacontrolsWrite 3 }
pmoari OBJECT IDENTIFIER ::= { modulepmoa 7 }
pmoaConfig OBJECT IDENTIFIER ::= { modulepmoa 9 }
pmoatraps OBJECT IDENTIFIER ::= { modulepmoa 10 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- TEXTUAL-CONVENTION
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
PmoapreampMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Different modes on OA preamp"
SYNTAX INTEGER {
oapreampdefaultmode(0),
oapreampconstantcurrentmode(1),
oapreampconstantpowermode(2)
}
PmoaboosterMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Different modes on OA booster"
SYNTAX INTEGER {
oaboosterdefaultmode(0),
oaboosterconstantcurrentmode(1),
oaboosterconstantpowermode(2)
}
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- REMOTE INVENTORY
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
pmoaRinvReloadInventory OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reload the inventory: This OID triggers an
inventory reload."
::= { pmoari 2 }
pmoaRinvModulePlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module platform description: This OID contains the
description of the Module."
::= { pmoari 3 }
pmoaRinvSwPlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SW platform description: This OID contains the
description of the Software platform."
::= { pmoari 4 }
pmoaRinvSwFoa OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical device driver description: This OID contains
the description of the driver of the optical devices
(Booster and Pre-Amp)"
::= { pmoari 5 }
pmoaRinvBoosterTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmoaRinvBoosterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of the Boosters on the selected module"
::= { pmoari 6 }
pmoaRinvBoosterEntry OBJECT-TYPE
SYNTAX PmoaRinvBoosterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Row definition for the Boosters table"
INDEX { pmoaRinvBoosterIndex }
::= { pmoaRinvBoosterTable 1 }
PmoaRinvBoosterEntry::=
SEQUENCE {
pmoaRinvBoosterIndex
Integer32,
pmoaRinvBooster
DisplayString
}
pmoaRinvBoosterIndex OBJECT-TYPE
SYNTAX Integer32(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for Booster table"
::= { pmoaRinvBoosterEntry 1 }
pmoaRinvBooster OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Inventory for the Booster: This OID contains the inventory for the Booster"
::= { pmoaRinvBoosterEntry 2 }
pmoaRinvPreAmpTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmoaRinvPreAmpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of the PreAmps on the selected module"
::= { pmoari 7 }
pmoaRinvPreAmpEntry OBJECT-TYPE
SYNTAX PmoaRinvPreAmpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Row definition for the PreAmp table"
INDEX { pmoaRinvPreAmpIndex }
::= { pmoaRinvPreAmpTable 1 }
PmoaRinvPreAmpEntry::=
SEQUENCE {
pmoaRinvPreAmpIndex
Integer32,
pmoaRinvPreAmp
DisplayString
}
pmoaRinvPreAmpIndex OBJECT-TYPE
SYNTAX Integer32(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for PreAmp table"
::= { pmoaRinvPreAmpEntry 1 }
pmoaRinvPreAmp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Inventory for the PreAmp: This OID contains the inventory for the PreAmp"
::= { pmoaRinvPreAmpEntry 2 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- ALARMS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the synthAlm0 article
--- *****************************************************
pmoaAlmsynthAlm0 OBJECT IDENTIFIER ::= { pmoaAlmOtherCrit 0 }
pmoaAlmDefFuseB OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Fuse B Fail :This OID indicates
that the fuse of the power input
B is in fail condition <Help>
Status of the Fuse B <Condtype>
DEF_FUSE_B <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoaAlmsynthAlm0 16 }
pmoaAlmDefFuseA OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Fuse A Fail :This OID indicates
that the fuse of the power input
A is in fail condition <Help>
Status of the Fuse A <Condtype>
DEF_FUSE_A <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoaAlmsynthAlm0 15 }
pmoaAlmExtPumpNotLocked OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
External Pump1 Not Detected :This
OID indicates that the first external
pump is not detected by the amplifier
module <Help> This alarm indicates
if the first external pump is detected
by the amplifier module <Condtype>
EXT_PUMP_NOT_LOCKED <Probcause>
pumpFailure (39) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoaAlmsynthAlm0 12 }
pmoaAlmDwEdfaInitNotCompl OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Not Initialized :This
OID indicates that the initialisation
of the Pre-Amp is not completed
<Help> This status indicates
if the Pre-Amp has been correctly
initialized <Condtype> DW_EDFA_INIT_NOT_COMPL
<Probcause> other (1) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmoaAlmsynthAlm0 11 }
pmoaAlmUpEdfaInitNotCompl OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Not Initialized :This
OID indicates that the initialisation
of the Booster is not completed
<Help> This status indicates
if the Booster has been correctly
initialized <Condtype> UP_EDFA_INIT_NOT_COMPL
<Probcause> other (1) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmoaAlmsynthAlm0 10 }
pmoaAlmModGlobFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Module Failure :This OID is set
on detection of a failure originating
from the PM <Condtype> MOD_GLOB_FAIL
<Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmoaAlmsynthAlm0 9 }
pmoaAlmMaintenanceMode OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Maintenance Mode :This OID indicates
that the PM is in maintenance mode
<Help> This status indiates if
the module is currently in maintenance
mode <Condtype> MAINTENANCE_MODE
<Probcause> other (1) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmoaAlmsynthAlm0 1 }
--- *****************************************************
--- LEAF for the synthAlm2 article
--- *****************************************************
pmoaAlmsynthAlm2 OBJECT IDENTIFIER ::= { pmoaAlmOtherNurg 2 }
pmoaAlmConfTableLoad OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
PM Configuration Load :This OID
is at 1 during the loading of
configuration tables in the modules
RAM. <Condtype> CONF_TABLE_LOAD
<Probcause> other (1) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmoaAlmsynthAlm2 3 }
pmoaAlmInvUpload OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Inventory Upload :This OID is
at 1 during the uploading of PM
inventory information. <Condtype>
INV_UPLOAD <Probcause> other (1)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pmoaAlmsynthAlm2 2 }
pmoaAlmConfTableSave OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
PM Configuration Save :This OID
is at 1 during the saving of a
new configuration table in the
module Flash memory. <Condtype>
CONF_TABLE_SAVE <Probcause> other
(1) <Alarmtype> other (1) <Polarity>
(2)
"
::= { pmoaAlmsynthAlm2 1 }
--- *****************************************************
--- LEAF for the synthAlm7 article
--- *****************************************************
pmoaAlmsynthAlm7 OBJECT IDENTIFIER ::= { pmoaAlmLineCrit 7 }
pmoaAlmLineFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Port Failure :This OID indicates
a failure on the line port <Condtype>
LINE_FAIL <Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmoaAlmsynthAlm7 12 }
pmoaAlmLineDdmAlm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Alarm On Line Optical Module DDM
:This OID indicates an alarm is
present coming out of Line optical
interface DDM <Condtype> LINE_DDM_ALM
<Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmoaAlmsynthAlm7 10 }
pmoaAlmLineDdmWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Warning On Line Optical Module
DDM :This OID indicates a warning
is present coming out of Line optical
interface DDM <Condtype> LINE_DDM_WARNING
<Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmoaAlmsynthAlm7 9 }
pmoaAlmLineTxOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Optical Output Shutdown
:This OID indicates the Booster
optical output power is on <Help>
This status indicates if the Booster
laser pump is ON or OFF <Condtype>
LINE_TX_OFF <Probcause> other (1)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmoaAlmsynthAlm7 5 }
pmoaAlmLineHwFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Port HW Failure :This OID
indicates a failure on line port,
most probably caused by a HW issue
<Condtype> LINE_HW_FAIL <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pmoaAlmsynthAlm7 4 }
--- *****************************************************
--- LEAF for the synthAlm8 article
--- *****************************************************
pmoaAlmsynthAlm8 OBJECT IDENTIFIER ::= { pmoaAlmClientCrit 8 }
pmoaAlmClientFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Port Failure :This OID
indicates a failure on the Client
port <Condtype> CLIENT_FAIL <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pmoaAlmsynthAlm8 12 }
pmoaAlmClientDdmAlm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Alarm On Client Optical Module
DDM :This OID indicates an alarm
is present coming out of Client
optical interface DDM <Condtype>
CLIENT_DDM_ALM <Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmoaAlmsynthAlm8 10 }
pmoaAlmClientDdmWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Warning On Client Optical Module
DDM :This OID indicates a warning
is present coming out of Client
optical interface DDM <Condtype>
CLIENT_DDM_WARNING <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pmoaAlmsynthAlm8 9 }
pmoaAlmClientTxOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Optical Output Shutdown
:This OID indicates the Pre-Amp
optical output power is on <Help>
This status indicates if the Pre-Amp
laser pump transceiver laser is
ON or OFF <Condtype> CLIENT_TX_OFF
<Probcause> other (1) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoaAlmsynthAlm8 5 }
pmoaAlmClientHwFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Port HW Failure :This OID
indicates a failure on Client port,
most probably caused by a HW issue
<Condtype> CLIENT_HW_FAIL <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pmoaAlmsynthAlm8 4 }
--- *****************************************************
--- LEAF for the clientEdfaAlarms1 article
--- *****************************************************
pmoaAlmclientEdfaAlarms1 OBJECT IDENTIFIER ::= { pmoaAlmClientUrg 32 }
pmoaAlmClientBiasHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Bias High Alarm :This
OID indicates that the Bias is
higher than the alarm theshold
of the Pre-Amp Optical Module
<Help> This alarm indicates
if the Pre-Amp bias is too high
<Condtype> CLIENT_BIAS_HIGH_ALARM
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoaAlmclientEdfaAlarms1 8 }
pmoaAlmClientBiasLowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Bias Low Alarm :This OID
indicates that the Bias is lower
than the alarm theshold of the
Pre-Amp Optical Module <Help>
This alarm indicates if the Pre-Amp
bias is too low <Condtype> CLIENT_BIAS_LOW_ALARM
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoaAlmclientEdfaAlarms1 7 }
pmoaAlmClientOutputPwrHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Tx Pwr High Alarm :This
OID indicates that the Transmit
Power is higher than the alarm
theshold of the Pre-Amp Optical
Module <Help> This alarm indicates
if the Pre-Amp tx power is too
high <Condtype> CLIENT_OUTPUT_PWR_HIGH_ALARM
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoaAlmclientEdfaAlarms1 6 }
pmoaAlmClientOutputPwrLowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Tx Pwr Low Alarm :This
OID indicates that the Transmit
Power is lower than the alarm theshold
of the Pre-Amp Optical Module
<Help> This alarm indicates if
the Pre-Amp tx power is too low
<Condtype> CLIENT_OUTPUT_PWR_LOW_ALARM
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoaAlmclientEdfaAlarms1 5 }
pmoaAlmClientInputPwrHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Rx Pwr High Alarm :This
OID indicates that the Receive
Power is higher than the alarm
theshold of the Booster Optical
Module <Help> This alarm indicates
if the Booster rx power is too
high <Condtype> CLIENT_INPUT_PWR_HIGH_ALARM
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmoaAlmclientEdfaAlarms1 4 }
pmoaAlmClientInputPwrLowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Rx Pwr Low Alarm :This
OID indicates that the Receive
Power is lower than the alarm
theshold of the Booster Optical
Module <Help> This alarm indicates
if the Booster rx power is too
low <Condtype> CLIENT_INPUT_PWR_LOW_ALARM
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmoaAlmclientEdfaAlarms1 3 }
pmoaAlmClientGainHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Gain High Alarm :This
OID indicates that the Gain is
higher than the alarm threshold
of the Pre-Amp Module <Help>
This alarm indicates if the Pre-Amp
gain is too high <Condtype> CLIENT_GAIN_HIGH_ALARM
<Probcause> performanceDegraded
(35) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoaAlmclientEdfaAlarms1 2 }
pmoaAlmClientGainLowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Gain Low Alarm :This OID
indicates that the Gain is lower
than the alarm theshold of the
Pre-Amp Module <Help> This alarm
indicates if the Pre-Amp gain is
too low <Condtype> CLIENT_GAIN_LOW_ALARM
<Probcause> performanceDegraded
(35) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoaAlmclientEdfaAlarms1 1 }
--- *****************************************************
--- LEAF for the clientEdfaWarnings article
--- *****************************************************
pmoaAlmclientEdfaWarnings OBJECT IDENTIFIER ::= { pmoaAlmClientNurg 33 }
pmoaAlmClientBiasHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Bias High Warning :This
OID indicates that the Bias is
higher than the Warning theshold
of the Pre-Amp Optical Module
<Help> This warning indicates
if the Pre-Amp bias is too high
<Condtype> CLIENT_BIAS_HIGH_WARNING
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoaAlmclientEdfaWarnings 8 }
pmoaAlmClientBiasLowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Bias Low Warning :This
OID indicates that the Bias is
lower than the Warning theshold
of the Pre-Amp Optical Module
<Help> This warning indicates
if the Pre-Amp bias is too low
<Condtype> CLIENT_BIAS_LOW_WARNING
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoaAlmclientEdfaWarnings 7 }
pmoaAlmClientOutputPwrHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Tx Pwr High Warning :This
OID indicates that the Transmit
Power is higher than the Warning
theshold of the Pre-Amp Optical
Module <Help> This warning indicates
if the Pre-Amp tx power is too
high <Condtype> CLIENT_OUTPUT_PWR_HIGH_WARNING
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoaAlmclientEdfaWarnings 6 }
pmoaAlmClientOutputPwrLowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Tx Pwr Low Warning :This
OID indicates that the Transmit
Power is lower than the Warning
theshold of the Pre-Amp Optical
Module <Help> This warning indicates
if the Pre-Amp tx power is too
low <Condtype> CLIENT_OUTPUT_PWR_LOW_WARNING
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoaAlmclientEdfaWarnings 5 }
pmoaAlmClientInputPwrHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Rx Pwr High Warning :This
OID indicates that the Receive
Power is higher than the Warning
theshold of the Booster Optical
Module <Help> This warning indicates
if the Booster rx power is too
high <Condtype> CLIENT_INPUT_PWR_HIGH_WARNING
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmoaAlmclientEdfaWarnings 4 }
pmoaAlmClientInputPwrLowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Rx Pwr Low Warning :This
OID indicates that the Receive
Power is lower than the Warning
theshold of the Booster Optical
Module <Help> This warning indicates
if the Booster rx power is too
low <Condtype> CLIENT_INPUT_PWR_LOW_WARNING
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmoaAlmclientEdfaWarnings 3 }
pmoaAlmClientGainHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Gain High Warning :This
OID indicates that the Gain is
higher than the Warning threshold
of the Pre-Amp Module <Help>
This alarm indicates if the Pre-Amp
gain is too high <Condtype> CLIENT_GAIN_HIGH_WARNING
<Probcause> performanceDegraded
(35) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoaAlmclientEdfaWarnings 2 }
pmoaAlmClientGainLowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Gain Low Warning :This
OID indicates that the Gain is
lower than the Warning theshold
of the Pre-Amp Module <Help>
This alarm indicates if the Pre-Amp
gain is too low <Condtype> CLIENT_GAIN_LOW_WARNING
<Probcause> performanceDegraded
(35) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoaAlmclientEdfaWarnings 1 }
--- *****************************************************
--- LEAF for the clientEdfaAlarms2 article
--- *****************************************************
pmoaAlmclientEdfaAlarms2 OBJECT IDENTIFIER ::= { pmoaAlmClientCrit 35 }
pmoaAlmClientExtPumpEdfaLowCurrent OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp External Pump1 Low Current
:This OID indicates that the EDFA
pump current of the first external
pump linked to the Pre-Amp is too
low <Help> This alarm indicates
that the EDFA pump current of the
first external pump linked to the
Pre-Amp is too low <Condtype> CLIENT_EXT_PUMP_EDFA_LOW_CURRENT
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoaAlmclientEdfaAlarms2 5 }
pmoaAlmClientEdfaLos OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Loss Of Signal :This OID
indicates a Loss of Signal on the
Booster Optical Module <Help>
This alarm indicates if an optical
signal is detected on the Booster
input <Condtype> CLIENT_EDFA_LOS
<Probcause> receiveFailure (41)
<Alarmtype> physicalViolation (9)
<Polarity> (2)
"
::= { pmoaAlmclientEdfaAlarms2 4 }
pmoaAlmClientEdfaLaserFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Pump Laser Fail :This
OID indicates a Transmit Laser
Fail on the Pre-Amp Optical Module
<Help> This alarm indicates if
the laser of the Pre-Amp is in
fail condition <Condtype> CLIENT_EDFA_LASER_FAIL
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoaAlmclientEdfaAlarms2 3 }
pmoaAlmClientEdfaTecFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp TEC Fail :This OID indicates
that the TEC is in fail condition
on the Pre-Amp Optical Module
<Help> This alarm indicates if
the TEC of the Pre-Amp is in fail
condition <Condtype> CLIENT_EDFA_TEC_FAIL
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoaAlmclientEdfaAlarms2 2 }
pmoaAlmClientEdfaNr OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Optical Module Not Ready
:This OID indicates that the Pre-Amp
Optical Module is not ready <Help>
This status indicates if the Pre-Amp
has been correctly initialized
<Condtype> CLIENT_EDFA_NR <Probcause>
equipmentMalfunction (16) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoaAlmclientEdfaAlarms2 1 }
--- *****************************************************
--- LEAF for the lineEdfaAlarms1 article
--- *****************************************************
pmoaAlmlineEdfaAlarms1 OBJECT IDENTIFIER ::= { pmoaAlmLineUrg 40 }
pmoaAlmLineBiasHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Bias High Alarm :This
OID indicates that the Bias is
higher than the alarm theshold
of the Booster Optical Module
<Help> This alarm indicates
if the Booster bias is too high
<Condtype> LINE_BIAS_HIGH_ALARM
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoaAlmlineEdfaAlarms1 8 }
pmoaAlmLineBiasLowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Bias Low Alarm :This OID
indicates that the Bias is lower
than the alarm theshold of the
Booster Optical Module <Help>
This alarm indicates if the Booster
bias is too low <Condtype> LINE_BIAS_LOW_ALARM
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoaAlmlineEdfaAlarms1 7 }
pmoaAlmLineOutputPwrHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Tx Pwr High Alarm :This
OID indicates that the Transmit
Power is higher than the alarm
theshold of the Booster Optical
Module <Help> This alarm indicates
if the Booster tx power is too
high <Condtype> LINE_OUTPUT_PWR_HIGH_ALARM
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoaAlmlineEdfaAlarms1 6 }
pmoaAlmLineOutputPwrLowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Tx Pwr Low Alarm :This
OID indicates that the Transmit
Power is lower than the alarm theshold
of the Booster Optical Module
<Help> This alarm indicates if
the Booster tx power is too low
<Condtype> LINE_OUTPUT_PWR_LOW_ALARM
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoaAlmlineEdfaAlarms1 5 }
pmoaAlmLineInputPwrHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Rx Pwr High Alarm :This
OID indicates that the Receive
Power is higher than the alarm
theshold of the Pre-Amp Optical
Module <Help> This alarm indicates
if the Pre-Amp rx power is too
high <Condtype> LINE_INPUT_PWR_HIGH_ALARM
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmoaAlmlineEdfaAlarms1 4 }
pmoaAlmLineInputPwrLowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Rx Pwr Low Alarm :This
OID indicates that the Receive
Power is lower than the alarm
theshold of the Pre-Amp Optical
Module <Help> This alarm indicates
if the Pre-Amp rx power is too
low <Condtype> LINE_INPUT_PWR_LOW_ALARM
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmoaAlmlineEdfaAlarms1 3 }
pmoaAlmLineGainHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Gain High Alarm :This
OID indicates that the Gain is
higher than the alarm threshold
of the Booster Module <Help>
This alarm indicates if the Booster
gain is too high <Condtype> LINE_GAIN_HIGH_ALARM
<Probcause> performanceDegraded
(35) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoaAlmlineEdfaAlarms1 2 }
pmoaAlmLineGainLowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Gain Low Alarm :This OID
indicates that the Gain is lower
than the alarm theshold of the
Booster Module <Help> This alarm
indicates if the Booster gain is
too low <Condtype> LINE_GAIN_LOW_ALARM
<Probcause> performanceDegraded
(35) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoaAlmlineEdfaAlarms1 1 }
--- *****************************************************
--- LEAF for the lineEdfaWarnings article
--- *****************************************************
pmoaAlmlineEdfaWarnings OBJECT IDENTIFIER ::= { pmoaAlmLineNurg 41 }
pmoaAlmLineBiasHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Bias High Warning :This
OID indicates that the Bias is
higher than the Warning theshold
of the Booster Optical Module
<Help> This warning indicates
if the Booster bias is too high
<Condtype> LINE_BIAS_HIGH_WARNING
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoaAlmlineEdfaWarnings 8 }
pmoaAlmLineBiasLowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Bias Low Warning :This
OID indicates that the Bias is
lower than the Warning theshold
of the Booster Optical Module
<Help> This warning indicates
if the Booster bias is too low
<Condtype> LINE_BIAS_LOW_WARNING
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoaAlmlineEdfaWarnings 7 }
pmoaAlmLineOutputPwrHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Tx Pwr High Warning :This
OID indicates that the Transmit
Power is higher than the Warning
theshold of the Booster Optical
Module <Help> This warning indicates
if the Booster tx power is too
high <Condtype> LINE_OUTPUT_PWR_HIGH_WARNING
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoaAlmlineEdfaWarnings 6 }
pmoaAlmLineOutputPwrLowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Tx Pwr Low Warning :This
OID indicates that the Transmit
Power is lower than the Warning
theshold of the Booster Optical
Module <Help> This warning indicates
if the Booster tx power is too
low <Condtype> LINE_OUTPUT_PWR_LOW_WARNING
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoaAlmlineEdfaWarnings 5 }
pmoaAlmLineInputPwrHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Rx Pwr High Warning :This
OID indicates that the Receive
Power is higher than the Warning
theshold of the Pre-Amp Optical
Module <Help> This warning indicates
if the Pre-Amp rx power is too
high <Condtype> LINE_INPUT_PWR_HIGH_WARNING
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmoaAlmlineEdfaWarnings 4 }
pmoaAlmLineInputPwrLowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Rx Pwr Low Warning :This
OID indicates that the Receive
Power is lower than the Warning
theshold of the Pre-Amp Optical
Module <Help> This warning indicates
if the Pre-Amp rx power is too
low <Condtype> LINE_INPUT_PWR_LOW_WARNING
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmoaAlmlineEdfaWarnings 3 }
pmoaAlmLineGainHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Gain High Warning :This
OID indicates that the Gain is
higher than the Warning threshold
of the Booster Module <Help>
This alarm indicates if the Booster
gain is too high <Condtype> LINE_GAIN_HIGH_WARNING
<Probcause> performanceDegraded
(35) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoaAlmlineEdfaWarnings 2 }
pmoaAlmLineGainLowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Gain Low Warning :This
OID indicates that the Gain is
lower than the Warning theshold
of the Booster Module <Help>
This alarm indicates if the Booster
gain is too low <Condtype> LINE_GAIN_LOW_WARNING
<Probcause> performanceDegraded
(35) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoaAlmlineEdfaWarnings 1 }
--- *****************************************************
--- LEAF for the lineEdfaAlarms2 article
--- *****************************************************
pmoaAlmlineEdfaAlarms2 OBJECT IDENTIFIER ::= { pmoaAlmLineCrit 43 }
pmoaAlmLineExtPumpEdfaLowCurrent OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster External Pump1 Low Current
:This OID indicates that the EDFA
pump current of the first external
pump linked to the Booster is too
low <Help> This alarm indicates
that the EDFA pump current of the
first external pump linked to the
Booster is too low. <Condtype>
LINE_EXT_PUMP_EDFA_LOW_CURRENT
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoaAlmlineEdfaAlarms2 5 }
pmoaAlmLineEdfaLos OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Loss Of Signal :This OID
indicates a Loss of Signal on the
Pre-Amp Optical Module <Help>
This alarm indicates if an optical
signal is detected on the Pre-Amp
input <Condtype> LINE_EDFA_LOS
<Probcause> receiveFailure (41)
<Alarmtype> physicalViolation (9)
<Polarity> (2)
"
::= { pmoaAlmlineEdfaAlarms2 4 }
pmoaAlmLineEdfaLaserFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Pump Laser Fail :This
OID indicates a Transmit Laser
Fail on the Booster Optical Module
<Help> This alarm indicates if
the laser of the Booster is in
fail condition <Condtype> LINE_EDFA_LASER_FAIL
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoaAlmlineEdfaAlarms2 3 }
pmoaAlmLineEdfaTecFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster TEC Fail :This OID indicates
that the TEC is in fail condition
on the Booster Optical Module
<Help> This alarm indicates if
the TEC of the Booster is in fail
condition <Condtype> LINE_EDFA_TEC_FAIL
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoaAlmlineEdfaAlarms2 2 }
pmoaAlmLineEdfaNr OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Optical Module Not Ready
:This OID indicates that the Booster
Optical Module is not ready <Help>
This status indicates if the Booster
has been correctly initialized
<Condtype> LINE_EDFA_NR <Probcause>
equipmentMalfunction (16) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoaAlmlineEdfaAlarms2 1 }
--- *****************************************************
--- LEAF for the foaAlarms article
--- *****************************************************
pmoaAlmfoaAlarms OBJECT IDENTIFIER ::= { pmoaAlmOtherUrg 74 }
pmoaAlmTempHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Temperature High Alarm :This OID
indicates that the PM temperature
is higher than the alarm threshold
<Condtype> TEMP_HIGH_ALARM <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoaAlmfoaAlarms 8 }
pmoaAlmTermpLowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Temperature Low Alarm :This OID
indicates that the PM temperature
if lower than the alarm threshold
<Condtype> TERMP_LOW_ALARM <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoaAlmfoaAlarms 7 }
pmoaAlm3v3HighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
3V3 High Alarm :This OID indicates
that the PM 3V3 voltage is higher
than the alarm threshold <Condtype>
3V3_HIGH_ALARM <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoaAlmfoaAlarms 6 }
pmoaAlm3v3LowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
3V3 Low Alarm :This OID indicates
that the PM 3V3 voltage is lower
than the alarm threshold <Condtype>
3V3_LOW_ALARM <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoaAlmfoaAlarms 5 }
--- *****************************************************
--- LEAF for the foaWarnings article
--- *****************************************************
pmoaAlmfoaWarnings OBJECT IDENTIFIER ::= { pmoaAlmOtherNurg 75 }
pmoaAlmTempHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Temperature High Warning :This
OID indicates that the PM temperature
if higher than the Warning threshold
<Condtype> TEMP_HIGH_WARNING <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoaAlmfoaWarnings 8 }
pmoaAlmTermpLowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Temperature Low Warning :This
OID indicates that the PM temperature
if lower than the Warning threshold
<Condtype> TERMP_LOW_WARNING <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoaAlmfoaWarnings 7 }
pmoaAlm3v3HighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
3V3 High Warning :This OID indicates
that the PM 3V3 voltage is higher
than the Warning threshold <Condtype>
3V3_HIGH_WARNING <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoaAlmfoaWarnings 6 }
pmoaAlm3v3LowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
3V3 Low Warning :This OID indicates
that the PM 3V3 voltage is lower
than the Warning threshold <Condtype>
3V3_LOW_WARNING <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoaAlmfoaWarnings 5 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- CONTROLS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the synth0 article
--- *****************************************************
pmoaCtrlsynth0 OBJECT IDENTIFIER ::= { pmoaCtrlOther 0 }
pmoaCtrlConfClear OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Clear Configuration Tables :This
bit clears the configuration tables
from configuration in the flash.
<Help> This control restores
the default configuration of the
module
"
::= { pmoaCtrlsynth0 13 }
pmoaCtrlConfFlash OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Write Configuration Tables :This
bit saves the current configuration
of the module as configuration
in the flash. <Help> This control
saves the customer configuration
on the module
"
::= { pmoaCtrlsynth0 9 }
pmoaCtrlConfLoad OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Load Configuration Tables :When
set this enables loading from flash
configuration1 into the module.
"
::= { pmoaCtrlsynth0 1 }
--- *****************************************************
--- LEAF for the swMgnt article
--- *****************************************************
pmoaCtrlswMgnt OBJECT IDENTIFIER ::= { pmoaCtrlOther 5 }
pmoaCtrlWarmReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
PM Warm Reset :This OID, when
set, causes a warm reset of the
Software. This reset is not traffic
affecting, and the configuration
of the Sofwtare remains unchanged.
<Help> This control initiates
a warm reset of the module.
"
::= { pmoaCtrlswMgnt 3 }
pmoaCtrlColdReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
PM Cold Reset :This OID, when
set, causes a cold reset of the
Software. This reset is traffic
affecting, and the configuration
of Software is reloaded on start-up.
<Help> This control initiates
a cold reset of the module.
"
::= { pmoaCtrlswMgnt 2 }
--- *****************************************************
--- LEAF for the clientEdfaLaserOff article
--- *****************************************************
pmoaCtrlclientEdfaLaserOff OBJECT IDENTIFIER ::= { pmoaCtrlClient 32 }
pmoaCtrlClientEdfaLaserOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Pre-Amp Pump Laser Shutdown :This
OID switches OFF the laser of the
Pre-Amp Optical Module <Help>
This control defines the laser
state of the Pre-Amp
"
::= { pmoaCtrlclientEdfaLaserOff 1 }
--- *****************************************************
--- LEAF for the clientEdfaMode article
--- *****************************************************
pmoaCtrlclientEdfaMode OBJECT-TYPE
SYNTAX PmoapreampMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Pre-Amp Module Mode :This OID
selects the mode of the Pre-Amp
Module <Help> This control defines
the Pre-Amp Mode (0: Default mode,
2:Constant output power)
"
::= { pmoaCtrlClient 33 }
--- *****************************************************
--- LEAF for the clientIlasSettingValue article
--- *****************************************************
pmoaCtrlclientIlasSettingValue OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Pre-Amp Laser Current Value :This
OID sets the value of the laser
current of the Pre-Amp Module (active
only in constant current mode)
(AV = Current *100) (Unit = mA)
<Help> This control defines the
Pre-Amp Laser current in mA (valid
only in constant current mode)
"
::= { pmoaCtrlClient 34 }
--- *****************************************************
--- LEAF for the clientPlasSettingValue article
--- *****************************************************
pmoaCtrlclientPlasSettingValue OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Pre-Amp Pump Power Value :This
OID sets the value of the laser
power of the Pre-Amp Optical Module
(active only in constant power
mode) (AV=(Power/0,005) + 32768)
(Unit = dBm) <Help> This control
defines the Pre-Amp laser power
in dBm (valid only in constant
output power mode)
"
::= { pmoaCtrlClient 35 }
--- *****************************************************
--- LEAF for the clientGainSettingValue article
--- *****************************************************
pmoaCtrlclientGainSettingValue OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Pre-Amp Gain Value :This OID sets
the value of the gain of the Pre-Amp
Module (active only in constant
gain mode) (AV=(Gain/0,005) + 32768)
(Unit = dB)
"
::= { pmoaCtrlClient 36 }
--- *****************************************************
--- LEAF for the clientEffPwrOutSettingValue article
--- *****************************************************
pmoaCtrlclientEffPwrOutSettingValue OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Pre-Amp Effective Output Power
:This OID sets the value of the
effective output power (without
noise power) of the Pre-Amp Module
(active only in input power function
mode) (AV=(Power/0,005) + 32768)
(Unit = dBm) <Help> This control
defines the Pre-Amp effective output
power in dBm (valid only in Effective
Ouput power mode).
"
::= { pmoaCtrlClient 37 }
--- *****************************************************
--- LEAF for the lineEdfaLaserOff article
--- *****************************************************
pmoaCtrllineEdfaLaserOff OBJECT IDENTIFIER ::= { pmoaCtrlLine 40 }
pmoaCtrlLineEdfaLaserOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Booster Pump Laser Shutdown :This
OID switches OFF the laser of the
Booster Optical Module <Help>
This control defines the laser
state of the Booster
"
::= { pmoaCtrllineEdfaLaserOff 1 }
--- *****************************************************
--- LEAF for the lineEdfaMode article
--- *****************************************************
pmoaCtrllineEdfaMode OBJECT-TYPE
SYNTAX PmoaboosterMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Booster Module Mode :This OID
selects the mode of the Booster
Module <Help> This control defines
the Booster Mode (0: Default mode,
2:Constant output power)
"
::= { pmoaCtrlLine 41 }
--- *****************************************************
--- LEAF for the lineIlasSettingValue article
--- *****************************************************
pmoaCtrllineIlasSettingValue OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Booster Laser Current Value :This
OID sets the value of the laser
current of the Booster Module (active
only in constant current mode)
(AV = Current *100) (Unit = mA)
<Help> This control defines the
Booster Laser current in mA (valid
only in constant current mode)
"
::= { pmoaCtrlLine 42 }
--- *****************************************************
--- LEAF for the linePlasSettingValue article
--- *****************************************************
pmoaCtrllinePlasSettingValue OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Booster Pump Power Value :This
OID sets the value of the laser
power of the Booster Optical Module
(active only in constant power
mode) (AV=(Power/0,005) + 32768)
(Unit = dBm) <Help> This control
defines the Booster laser power
in dBm (valid only in constant
output power mode)
"
::= { pmoaCtrlLine 43 }
--- *****************************************************
--- LEAF for the lineGainSettingValue article
--- *****************************************************
pmoaCtrllineGainSettingValue OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Booster Gain Value :This OID sets
the value of the gain of the Booster
Module (active only in constant
gain mode) (AV=(Gain/0,005) + 32768)
(Unit = dB)
"
::= { pmoaCtrlLine 44 }
--- *****************************************************
--- LEAF for the lineEffPwrOutSettingValue article
--- *****************************************************
pmoaCtrllineEffPwrOutSettingValue OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Booster Effective Output Power
:This OID sets the value of the
effective output power (without
noise power) of the Booster Module
(active only in input power function
mode) (AV=(Power/0,005) + 32768)
(Unit = dBm)
"
::= { pmoaCtrlLine 45 }
--- *****************************************************
--- LEAF for the powerDown article
--- *****************************************************
pmoaCtrlpowerDown OBJECT IDENTIFIER ::= { pmoaCtrlOther 72 }
pmoaCtrlSoftPowerDown OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Module Software Shutdown :This
OID shuts down the PM Software
<Help> This control initiates
a shut down of software.
"
::= { pmoaCtrlpowerDown 1 }
--- *****************************************************
--- LEAF for the ledTest article
--- *****************************************************
pmoaCtrlledTest OBJECT IDENTIFIER ::= { pmoaCtrlOther 73 }
pmoaCtrlLedOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Leds Off :This OID switches off
all the Leds as a test feature.
<Help> This control initiates
a test leds turning all the LEDs
to OFF
"
::= { pmoaCtrlledTest 3 }
pmoaCtrlRedLed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Red Leds Test :This OID switches
on all the red Leds as a test feature.
<Help> This control initiates
a test leds turning all the LEDs
to red
"
::= { pmoaCtrlledTest 2 }
pmoaCtrlGreenLed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Green Leds Test :This OID switches
on all the green Leds as a test
feature. <Help> This control
initiates a test leds turning
all the LEDs to green
"
::= { pmoaCtrlledTest 1 }
--- *****************************************************
--- LEAF for the maintMode article
--- *****************************************************
pmoaCtrlmaintMode OBJECT IDENTIFIER ::= { pmoaCtrlOther 75 }
pmoaCtrlMaintenance OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Module Maintenance Mode :This
OID sets the PM in maintenance
mode <Help> This control enables
the maintenance mode of the module
"
::= { pmoaCtrlmaintMode 1 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- MEASURES
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the clientEdfaBiasMeas article
--- *****************************************************
pmoaMesrclientEdfaBiasMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Pump Laser Current :This
OID gives the pump laser current
of the Pre-Amp Optical Module (Current
=AV/100) (Unit = mA) <Help> This
measure gives the bias of the Pre-Amp
pump laser
"
::= { pmoaMesrClient 32 }
--- *****************************************************
--- LEAF for the clientEdfaTxpwrMeas article
--- *****************************************************
pmoaMesrclientEdfaTxpwrMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Tx Power :This OID gives
the transmit power value of the
Pre-Amp Optical Module (Power =(AV-32768)*0,005)
(Unit = dBm) <Help> This measure
gives the Tx optical power of the
Pre-Amp
"
::= { pmoaMesrClient 33 }
--- *****************************************************
--- LEAF for the clientEdfaRxpwrMeas article
--- *****************************************************
pmoaMesrclientEdfaRxpwrMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Rx Power :This OID gives
the receive power value of the
Booster Optical Module (Power
=(AV-32768)*0,005) (Unit = dBm)
<Help> This measure gives the
Rx optical power of the Booster
"
::= { pmoaMesrClient 34 }
--- *****************************************************
--- LEAF for the clientEdfaGainMeas article
--- *****************************************************
pmoaMesrclientEdfaGainMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Gain :This OID gives the
gain value of the Pre-Amp Module
(Gain =(AV-32768)*0,005) (Unit
= dB) <Help> This measure gives
the optical gain of the Pre-Amp
"
::= { pmoaMesrClient 35 }
--- *****************************************************
--- LEAF for the lineEdfaBiasMeas article
--- *****************************************************
pmoaMesrlineEdfaBiasMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Pump Laser Current :This
OID gives the pump laser current
of the Booster Optical Module
(Current =AV/100) (Unit = mA)
<Help> This measure gives the
bias of the Booster pump laser
"
::= { pmoaMesrLine 40 }
--- *****************************************************
--- LEAF for the lineEdfaTxpwrMeas article
--- *****************************************************
pmoaMesrlineEdfaTxpwrMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Tx Power :This OID gives
the transmit power value of the
Booster Optical Module (Power =(AV-32768)*0,005)
(Unit = dBm) <Help> This measure
gives the Tx optical power of the
Booster
"
::= { pmoaMesrLine 41 }
--- *****************************************************
--- LEAF for the lineEdfaRxpwrMeas article
--- *****************************************************
pmoaMesrlineEdfaRxpwrMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Rx Power :This OID gives
the receive power value of the
Pre-Amp Optical Module (Power
=(AV-32768)*0,005) (Unit = dBm)
<Help> This measure gives the
Rx optical power of the Pre-Amp
"
::= { pmoaMesrLine 42 }
--- *****************************************************
--- LEAF for the lineEdfaGainMeas article
--- *****************************************************
pmoaMesrlineEdfaGainMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Gain :This OID gives the
gain value of the Booster Module
(Gain =(AV-32768)*0,005) (Unit
= dB) <Help> This measure gives
the optical gain of the Booster
"
::= { pmoaMesrLine 43 }
--- *****************************************************
--- LEAF for the tempMeas article
--- *****************************************************
pmoaMesrtempMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Module Temperature :This OID gives
the temperature of the PM (Temperature
=AV/256) (Unit = C) <Help> This
measure gives the temperature of
the module
"
::= { pmoaMesrOther 72 }
--- *****************************************************
--- LEAF for the 3v3Meas article
--- *****************************************************
pmoaMesr3v3Meas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Module 3.3 Voltage :This OID gives
the 3V3 voltage of the PM (Voltage
=AV/10000) (Unit = V) <Help>
This measure gives the 3V3 voltage
of the module
"
::= { pmoaMesrOther 73 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- CONFIG
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the table Group noValue
--- *****************************************************
pmoaCfgNoValue OBJECT IDENTIFIER ::= { pmoaConfig 1 }
--- *****************************************************
--- LEAF for the table 2111
--- *****************************************************
pmoatableclientStartup OBJECT IDENTIFIER ::= { pmoaCfgNoValue 1 }
pmoaCfgclientEdfaLaserCtrl OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Client Laser
:This OID configures the default
initialisation settings on the
client laser.
"
::= { pmoatableclientStartup 2 }
pmoaCfgclientEdfaLaserMode OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Client mode
:This OID configures the default
mode on the client amplifier.
"
::= { pmoatableclientStartup 3 }
--- *****************************************************
--- LEAF for the table Group lineStartUp
--- *****************************************************
pmoaCfgLineStartUp OBJECT IDENTIFIER ::= { pmoaConfig 2 }
--- *****************************************************
--- LEAF for the table 2191
--- *****************************************************
pmoatablelineStartup OBJECT IDENTIFIER ::= { pmoaCfgLineStartUp 1 }
pmoaCfglineEdfaLaserCtrl OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Line Laser
:This OID configures the default
initialisation settings on the
line laser.
"
::= { pmoatablelineStartup 2 }
pmoaCfglineEdfaLaserMode OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Line mode
:This OID configures the default
mode on the line amplifier.
"
::= { pmoatablelineStartup 3 }
--- *****************************************************
--- LEAF for the table Group labels
--- *****************************************************
pmoaCfgLabels OBJECT IDENTIFIER ::= { pmoaConfig 3 }
--- *****************************************************
--- LEAF for the table NO_VALUE
--- *****************************************************
pmoaCfgLabelclientTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmoaCfgLabelclientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pmoaCfgLabels 1 }
pmoaCfgLabelclientEntry OBJECT-TYPE
SYNTAX PmoaCfgLabelclientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the labels
table
"
INDEX { pmoaCfgLabelclientIndex }
::= { pmoaCfgLabelclientTable 1 }
PmoaCfgLabelclientEntry ::=
SEQUENCE {
pmoaCfgLabelclientIndex
INTEGER,
pmoaCfgLabelclientPortn
DisplayString
}
pmoaCfgLabelclientIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the labelclient
table
"
::= { pmoaCfgLabelclientEntry 1 }
pmoaCfgLabelclientPortn OBJECT-TYPE
SYNTAX DisplayString( SIZE(1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on the label
of the Ports :These registers
configures the default initialisation
settings of the labels of the ports.
"
::= { pmoaCfgLabelclientEntry 3 }
--- *****************************************************
--- LEAF for the table NO_VALUE
--- *****************************************************
pmoaCfgLabellineTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmoaCfgLabellineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pmoaCfgLabels 2 }
pmoaCfgLabellineEntry OBJECT-TYPE
SYNTAX PmoaCfgLabellineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the labels
table
"
INDEX { pmoaCfgLabellineIndex }
::= { pmoaCfgLabellineTable 1 }
PmoaCfgLabellineEntry ::=
SEQUENCE {
pmoaCfgLabellineIndex
INTEGER,
pmoaCfgLabellinePortn
DisplayString
}
pmoaCfgLabellineIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the labelline
table
"
::= { pmoaCfgLabellineEntry 1 }
pmoaCfgLabellinePortn OBJECT-TYPE
SYNTAX DisplayString( SIZE(1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on the label
of the lines :These registers
configures the default initialisation
settings of the labels of the lines.
"
::= { pmoaCfgLabellineEntry 3 }
pmoaCfgWriteConfiguration OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Write configuration to module:This OID
writes the complete configuration to the module"
::= { pmoaConfig 257 }
--- *****************************************************
--- TRAP OBJECTS
--- *****************************************************
pmoatrapBoardNumber OBJECT-TYPE
SYNTAX INTEGER(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last module which generates a trap"
::= { pmoatraps 4 }
--- *****************************************************
--- GLOBAL TRAPS
--- *****************************************************
pmoaLineTrapNotUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmoaAlmLineDdmWarning, pmoatrapBoardNumber}
STATUS current
--&FILTNAME "PMOA Line Not Urgent ON"
--&ACTIONS { log, minor }
--&MATCH { pmoaAlmLineDdmWarning "on", pmoatrapBoardNumber "$2"}
--&MESG "DDM Warning appears on Pre-Amp input or Booster Output of PMOA-BP in slot $2 ($A)"
DESCRIPTION "Not urgent Line default is activated"
::= { pmoatraps 30 }
pmoaLineTrapNotUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmoaAlmLineDdmWarning, pmoatrapBoardNumber}
STATUS current
--&FILTNAME "PMOA Line Not Urgent OFF"
--&ACTIONS { log, normal }
--&CLEARS {"PMOA Line Not Urgent ON"}
--&MATCH { pmoaAlmLineDdmWarning "on", pmoatrapBoardNumber "$2"}
--&MESG "DDM Warning disappears on Pre-Amp input or Booster Output of PMOA-BP in slot $2 ($A)"
DESCRIPTION "Not urgent Line default disappeared"
::= { pmoatraps 31 }
pmoaLineTrapUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmoaAlmLineDdmAlm, pmoatrapBoardNumber}
STATUS current
--&FILTNAME "PMOA Line Urgent ON"
--&ACTIONS { log, major }
--&MATCH { pmoaAlmLineDdmAlm "on", pmoatrapBoardNumber "$2"}
--&MESG "DDM Alarm appears on Pre-Amp input or Booster Output of PMOA-BP in slot $2 ($A)"
DESCRIPTION "Urgent Line default is activated"
::= { pmoatraps 32 }
pmoaLineTrapUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmoaAlmLineDdmAlm, pmoatrapBoardNumber}
STATUS current
--&FILTNAME "PMOA Line Urgent OFF"
--&ACTIONS { log, normal }
--&CLEARS {"PMOA Line Urgent ON"}
--&MATCH { pmoaAlmLineDdmAlm "on", pmoatrapBoardNumber "$2"}
--&MESG "DDM Alarm disappears on Pre-Amp input or Booster Output of PMOA-BP in slot $2 ($A)"
DESCRIPTION "Urgent Line default disappeared"
::= { pmoatraps 33 }
pmoaLineTrapCritGoesOn NOTIFICATION-TYPE
OBJECTS {pmoaAlmLineFail, pmoaAlmLineHwFail, pmoatrapBoardNumber}
STATUS current
--&FILTNAME "PMOA Line Fail ON"
--&ACTIONS { log, critical }
--&MATCH { pmoaAlmLineFail "on", pmoaAlmLineHwFail "*", pmoatrapBoardNumber "$3"}
--&MESG "Critical Alarm appears on Pre-Amp input or Booster Output of PMOA-BP in slot $3 ($A)"
--&FILTNAME "PMOA Line HW Fail ON (Hidden)"
--&ACTIONS { info }
--&MATCH { pmoaAlmLineFail "*", pmoaAlmLineHwFail "on", pmoatrapBoardNumber "$3"}
--&MESG "Critical Alarm appears on Pre-Amp input or Booster Output of PMOA-BP in slot $3 ($A)"
DESCRIPTION "Critical Line default is activated"
::= { pmoatraps 34 }
pmoaLineTrapCritGoesOff NOTIFICATION-TYPE
OBJECTS {pmoaAlmLineFail, pmoaAlmLineHwFail, pmoatrapBoardNumber}
STATUS current
--&FILTNAME "PMOA Line Fail OFF"
--&ACTIONS { log, normal }
--&CLEARS {"PMOA Line Fail ON"}
--&MATCH { pmoaAlmLineFail "on", pmoaAlmLineHwFail "*", pmoatrapBoardNumber "$3"}
--&MESG "Critical Alarm disappears on Pre-Amp input or Booster Output of PMOA-BP in slot $3 ($A)"
--&FILTNAME "PMOA Line HW Fail OFF (Hidden)"
--&ACTIONS { info }
--&MATCH { pmoaAlmLineFail "*", pmoaAlmLineHwFail "on", pmoatrapBoardNumber "$3"}
--&MESG "Critical Alarm disappears on Pre-Amp input or Booster Output of PMOA-BP in slot $3 ($A)"
DESCRIPTION "Critical Line default disappeared"
::= { pmoatraps 35 }
--- *****************************************************
--- PORTS TRAPS
--- *****************************************************
pmoaClientTrapNotUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmoaAlmClientDdmWarning, pmoatrapBoardNumber}
STATUS current
--&FILTNAME "PMOA Client Not Urgent ON"
--&ACTIONS { log, minor }
--&MATCH { pmoaAlmClientDdmWarning "on", pmoatrapBoardNumber "$2"}
--&MESG "DDM Warning appears on Booster input or Pre-Amp Output of PMOA-BP in slot $2 ($A)"
DESCRIPTION "Not urgent client default is activated"
::= { pmoatraps 40 }
pmoaClientTrapNotUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmoaAlmClientDdmWarning, pmoatrapBoardNumber}
STATUS current
--&FILTNAME "PMOA Client Not Urgent OFF"
--&ACTIONS { log, normal }
--&CLEARS {"PMOA Client Not Urgent ON"}
--&MATCH { pmoaAlmClientDdmWarning "on", pmoatrapBoardNumber "$2"}
--&MESG "DDM Warning disappears on Booster input or Pre-Amp Output of PMOA-BP in slot $2 ($A)"
DESCRIPTION "Not urgent client default disappeared"
::= { pmoatraps 41 }
pmoaClientTrapUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmoaAlmClientDdmAlm, pmoatrapBoardNumber}
STATUS current
--&FILTNAME "PMOA Client Urgent ON"
--&ACTIONS { log, major }
--&MATCH { pmoaAlmClientDdmAlm "on", pmoatrapBoardNumber "$2"}
--&MESG "DDM Alarm appears on Booster input or Pre-Amp Output of PMOA-BP in slot $2 ($A)"
DESCRIPTION "Urgent client default is activated"
::= { pmoatraps 42 }
pmoaClientTrapUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmoaAlmClientDdmAlm, pmoatrapBoardNumber}
STATUS current
--&FILTNAME "PMOA Client Urgent OFF"
--&ACTIONS { log, normal }
--&CLEARS {"PMOA Client Urgent ON"}
--&MATCH { pmoaAlmClientDdmAlm "on", pmoatrapBoardNumber "$2"}
--&MESG "DDM Alarm disappears on Booster input or Pre-Amp Output of PMOA-BP in slot $2 ($A)"
DESCRIPTION "Urgent client default disappeared"
::= { pmoatraps 43 }
pmoaClientTrapCritGoesOn NOTIFICATION-TYPE
OBJECTS {pmoaAlmClientFail, pmoaAlmClientHwFail, pmoatrapBoardNumber}
STATUS current
--&FILTNAME "PMOA Client Fail ON"
--&ACTIONS { log, critical }
--&MATCH { pmoaAlmClientFail "on", pmoaAlmClientHwFail "*", pmoatrapBoardNumber "$3"}
--&MESG "Critical Alarm appears on Booster input or Pre-Amp Output of PMOA-BP in slot $3 ($A)"
--&FILTNAME "PMOA Client HW Fail ON (Hidden)"
--&ACTIONS { info }
--&MATCH { pmoaAlmClientFail "*", pmoaAlmClientHwFail "on", pmoatrapBoardNumber "$3"}
--&MESG "Critical Alarm appears on Booster input or Pre-Amp Output of PMOA-BP in slot $3 ($A)"
DESCRIPTION "Critical client default is activated"
::= { pmoatraps 44 }
pmoaClientTrapCritGoesOff NOTIFICATION-TYPE
OBJECTS {pmoaAlmClientFail, pmoaAlmClientHwFail, pmoatrapBoardNumber}
STATUS current
--&FILTNAME "PMOA Client Fail OFF"
--&ACTIONS { log, normal }
--&CLEARS {"PMOA Client Fail ON"}
--&MATCH { pmoaAlmClientFail "on", pmoaAlmClientHwFail "*", pmoatrapBoardNumber "$3"}
--&MESG "Critical Alarm disappears on Booster input or Pre-Amp Output of PMOA-BP in slot $3 ($A)"
--&FILTNAME "PMOA Client HW Fail OFF (Hidden)"
--&ACTIONS { info }
--&MATCH { pmoaAlmClientFail "*", pmoaAlmClientHwFail "on", pmoatrapBoardNumber "$3"}
--&MESG "Critical Alarm disappears on Booster input or Pre-Amp Output of PMOA-BP in slot $3 ($A)"
DESCRIPTION "Critical client default disappeared"
::= { pmoatraps 45 }
--- *****************************************************
--- HW TRAPS
--- *****************************************************
pmoaPowerTrapUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmoaAlmDefFuseB, pmoaAlmDefFuseA , pmoatrapBoardNumber}
STATUS current
--&FILTNAME "PMOA Fuse A Fail ON"
--&ACTIONS { log, major }
--&MATCH { pmoaAlmDefFuseB "*", pmoaAlmDefFuseA "on", pmoatrapBoardNumber "$3"}
--&MESG "Power Input A Fail on PMOA-BP in Slot $3 ($A)"
--&FILTNAME "PMOA Fuse B Fail ON"
--&ACTIONS { log, major }
--&MATCH { pmoaAlmDefFuseB "on", pmoaAlmDefFuseA "*", pmoatrapBoardNumber "$3"}
--&MESG "Power Input B Fail on PMOA-BP in Slot $3 ($A)"
DESCRIPTION "Urgent power supply default is activated"
::= { pmoatraps 50 }
pmoaPowerTrapUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmoaAlmDefFuseB, pmoaAlmDefFuseA , pmoatrapBoardNumber}
STATUS current
--&FILTNAME "PMOA Fuse A&B Fail OFF"
--&ACTIONS { log, normal}
--&CLEARS { "PMOA Fuse A Fail ON", "PMOA Fuse B Fail ON" }
--&MATCH { pmoaAlmDefFuseB "on", pmoaAlmDefFuseA "on", pmoatrapBoardNumber "$3"}
--&MESG "Power Inputs A and B Present on PMOA-BP in Slot $3 ($A)"
DESCRIPTION "Urgent power supply default disappeared"
::= { pmoatraps 51 }
END