-- EKINOPS-Pm801RR.TXT: MIB
|
||
--
|
||
--MIB Part Number:3MI00101ACAD
|
||
--MIB Version:02
|
||
--
|
||
-- Copyright (c) 2016 by Ekinops
|
||
-- All rights reserved.
|
||
--
|
||
-- *****************************************************************
|
||
|
||
EKINOPS-Pm801RR-MIB DEFINITIONS ::= BEGIN
|
||
|
||
IMPORTS
|
||
ekinops,
|
||
EkiState,
|
||
EkiOnOff,
|
||
EkiMode,
|
||
EkiProtocol,
|
||
EkiApiState,
|
||
EkiSynchroMode,
|
||
EkiMeasureType
|
||
FROM EKINOPS-MIB
|
||
MODULE-IDENTITY,
|
||
OBJECT-TYPE,
|
||
NOTIFICATION-TYPE,
|
||
Unsigned32,
|
||
Integer32,
|
||
Counter32,
|
||
IpAddress
|
||
FROM SNMPv2-SMI
|
||
TEXTUAL-CONVENTION,
|
||
DisplayString
|
||
FROM SNMPv2-TC;
|
||
|
||
modulePm801RR MODULE-IDENTITY
|
||
LAST-UPDATED "201606070000Z"
|
||
ORGANIZATION "Ekinops"
|
||
CONTACT-INFO
|
||
"Ekinops
|
||
|
||
3, rue Blaise Pascal
|
||
F-22300 Lannion / FRANCE
|
||
|
||
Tel : +33 (0)2 96 05 00 30
|
||
Fax : +33 (0)2 96 48 62 39
|
||
|
||
E-mail: support@ekinops.net"
|
||
DESCRIPTION
|
||
"MIB for the Ekinops Pm801RR hardware."
|
||
REVISION "201008260000Z"
|
||
DESCRIPTION
|
||
"Initial Version."
|
||
|
||
REVISION "201008260000Z"
|
||
DESCRIPTION
|
||
"Creation"
|
||
REVISION "201011030000Z"
|
||
DESCRIPTION
|
||
"Formula in comments, Event on XFP init"
|
||
REVISION "201207040000Z"
|
||
DESCRIPTION
|
||
"Minor cosmetic updates"
|
||
REVISION "201403250000Z"
|
||
DESCRIPTION
|
||
"Probcause,AlarmType - NMS completion"
|
||
REVISION "201412090000Z"
|
||
DESCRIPTION
|
||
"Labels cosmetic updates"
|
||
REVISION "201605230000Z"
|
||
DESCRIPTION
|
||
"New AlarmType – synthesisAlarm (12)"
|
||
REVISION "201606070000Z"
|
||
DESCRIPTION
|
||
"Capabilities objects of Table 5"
|
||
::= { ekinops 48 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF LEVEL 2
|
||
--- *****************************************************
|
||
|
||
|
||
pm801rralarms OBJECT IDENTIFIER ::= { modulePm801RR 2 }
|
||
pm801rrAlmOther OBJECT IDENTIFIER ::= { pm801rralarms 1 }
|
||
pm801rrAlmOtherNurg OBJECT IDENTIFIER ::= { pm801rrAlmOther 1 }
|
||
pm801rrAlmOtherUrg OBJECT IDENTIFIER ::= { pm801rrAlmOther 2 }
|
||
pm801rrAlmOtherCrit OBJECT IDENTIFIER ::= { pm801rrAlmOther 3 }
|
||
|
||
pm801rrAlmClient OBJECT IDENTIFIER ::= { pm801rralarms 2 }
|
||
pm801rrAlmClientNurg OBJECT IDENTIFIER ::= { pm801rrAlmClient 1 }
|
||
pm801rrAlmClientUrg OBJECT IDENTIFIER ::= { pm801rrAlmClient 2 }
|
||
pm801rrAlmClientCrit OBJECT IDENTIFIER ::= { pm801rrAlmClient 3 }
|
||
|
||
pm801rrAlmLine OBJECT IDENTIFIER ::= { pm801rralarms 3 }
|
||
pm801rrAlmLineNurg OBJECT IDENTIFIER ::= { pm801rrAlmLine 1 }
|
||
pm801rrAlmLineUrg OBJECT IDENTIFIER ::= { pm801rrAlmLine 2 }
|
||
pm801rrAlmLineCrit OBJECT IDENTIFIER ::= { pm801rrAlmLine 3 }
|
||
|
||
|
||
pm801rrmeasures OBJECT IDENTIFIER ::= { modulePm801RR 3 }
|
||
pm801rrMesrOther OBJECT IDENTIFIER ::= { pm801rrmeasures 1 }
|
||
pm801rrMesrClient OBJECT IDENTIFIER ::= { pm801rrmeasures 2 }
|
||
pm801rrMesrLine OBJECT IDENTIFIER ::= { pm801rrmeasures 3 }
|
||
|
||
|
||
pm801rrcontrolsWrite OBJECT IDENTIFIER ::= { modulePm801RR 6 }
|
||
pm801rrCtrlOther OBJECT IDENTIFIER ::= { pm801rrcontrolsWrite 1 }
|
||
pm801rrCtrlClient OBJECT IDENTIFIER ::= { pm801rrcontrolsWrite 2 }
|
||
pm801rrCtrlLine OBJECT IDENTIFIER ::= { pm801rrcontrolsWrite 3 }
|
||
|
||
pm801rrri OBJECT IDENTIFIER ::= { modulePm801RR 7 }
|
||
|
||
|
||
pm801rrConfig OBJECT IDENTIFIER ::= { modulePm801RR 9 }
|
||
|
||
pm801rrtraps OBJECT IDENTIFIER ::= { modulePm801RR 10 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- TEXTUAL-CONVENTION
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
Pm801rrBitRate ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION "different rates for a client and line ports"
|
||
SYNTAX INTEGER {
|
||
rateOC192(0),
|
||
rate10GBELAN(1),
|
||
rate10GBEWAN(2),
|
||
rate10GFC(3),
|
||
rate10FECG975(4),
|
||
rate10FECG709(5)
|
||
}
|
||
|
||
Pm801rrOtxMode ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION "Different modes on OTX-TLH on client and line ports"
|
||
SYNTAX INTEGER {
|
||
otx80mode(1),
|
||
otx60mode(2),
|
||
otxadjustmode(4)
|
||
}
|
||
|
||
Pm801rrOtxGrid ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION "Different grids on OTX-TLH on client and line ports"
|
||
SYNTAX INTEGER {
|
||
otxgrid200(200),
|
||
otxgrid100(100),
|
||
otxgrid50(50)
|
||
}
|
||
|
||
Pm801rrAdjustValue ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION "Different values in Adjust mode on OTX-TLH on client and line ports"
|
||
SYNTAX INTEGER {
|
||
otxadjustvalue0(0),
|
||
otxadjustvalue1(1),
|
||
otxadjustvalue2(2),
|
||
otxadjustvalue3(3),
|
||
otxadjustvalue4(4),
|
||
otxadjustvalue5(5),
|
||
otxadjustvalue6(6),
|
||
otxadjustvalue7(7),
|
||
otxadjustvalue8(8),
|
||
otxadjustvalue9(9),
|
||
otxadjustvalue10(10)
|
||
}
|
||
|
||
Pm801rrOtxChannel ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION "Channel selection on OTX-TLH on client and line ports"
|
||
SYNTAX INTEGER
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- REMOTE INVENTORY
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
pm801rrRinvReloadInventory OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reload the inventory: This OID triggers an
|
||
inventory reload."
|
||
::= { pm801rrri 2 }
|
||
|
||
|
||
pm801rrRinvHwPlatform OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Module platform description: This OID contains the
|
||
description of the Module."
|
||
::= { pm801rrri 4 }
|
||
|
||
pm801rrRinvSwPlatform OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"SW platform description: This OID contains the
|
||
description of the Software platform."
|
||
::= { pm801rrri 5 }
|
||
|
||
pm801rrRinvClientXFP OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Inventory for the XFP: This OID contains the inventory for the Client XFP"
|
||
::= { pm801rrri 6 }
|
||
|
||
|
||
pm801rrRinvLineXFP OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Inventory for the XFP: This OID contains the inventory for the Line XFP"
|
||
::= { pm801rrri 7 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- ALARMS
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synthAlm0 article
|
||
--- *****************************************************
|
||
pm801rrAlmsynthAlm0 OBJECT IDENTIFIER ::= { pm801rrAlmOtherCrit 0 }
|
||
|
||
|
||
|
||
|
||
pm801rrAlmDefFuseB OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Fuse B Fail :This OID indicates
|
||
that the fuse of the power input
|
||
B is in fail condition <Help>
|
||
Status of the Fuse B <Condtype>
|
||
DEF_FUSE_B <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmsynthAlm0 16 }
|
||
|
||
|
||
|
||
pm801rrAlmDefFuseA OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Fuse A Fail :This OID indicates
|
||
that the fuse of the power input
|
||
A is in fail condition <Help>
|
||
Status of the Fuse A <Condtype>
|
||
DEF_FUSE_A <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmsynthAlm0 15 }
|
||
|
||
|
||
|
||
pm801rrAlmModuleGlobFailure OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Module Failure :This OID is set
|
||
on detection of a failure originating
|
||
from the PM <Condtype> MODULE_GLOB_FAILURE
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmsynthAlm0 9 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synthAlm7 article
|
||
--- *****************************************************
|
||
pm801rrAlmsynthAlm7 OBJECT IDENTIFIER ::= { pm801rrAlmLineCrit 7 }
|
||
|
||
|
||
|
||
|
||
pm801rrAlmLineVccAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 VCC Alarm :This OID indicates
|
||
an overall VCC alarm is set over
|
||
the Line 2 XFP <Condtype> LINE_VCC_ALARM
|
||
<Probcause> powerProblem (36) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmsynthAlm7 15 }
|
||
|
||
|
||
|
||
pm801rrAlmLineVccWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 VCC Warning :This OID indicates
|
||
an overall VCC warning is set over
|
||
the Line 2 XFP <Condtype> LINE_VCC_WARNING
|
||
<Probcause> powerProblem (36) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmsynthAlm7 14 }
|
||
|
||
|
||
|
||
pm801rrAlmLineFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Port Failure :This OID
|
||
indicates a failure on the Line
|
||
2 port <Condtype> LINE_FAIL <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
synthesisAlarm (12) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pm801rrAlmsynthAlm7 12 }
|
||
|
||
|
||
|
||
pm801rrAlmLineDdmAlm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Alarm On Line 2 Optical Module
|
||
DDM :This OID indicates an alarm
|
||
is present coming out of Line 2
|
||
optical interface DDM <Help>
|
||
This alarm indicates if a DDM
|
||
Alarm has been detected on the
|
||
line 2 transceiver <Condtype> LINE_DDM_ALM
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmsynthAlm7 10 }
|
||
|
||
|
||
|
||
pm801rrAlmLineDdmWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Warning On Line 2 Optical Module
|
||
DDM :This OID indicates a warning
|
||
is present coming out of Line 2
|
||
optical interface DDM <Help>
|
||
This alarm indicates if a DDM
|
||
Warning has been detected on the
|
||
line 2 transceiver <Condtype> LINE_DDM_WARNING
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmsynthAlm7 9 }
|
||
|
||
|
||
|
||
pm801rrAlmLineXfpTxOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Optical Module Laser Shutdown
|
||
:This OID indicates the Line 2
|
||
optical output power is off <Help>
|
||
This status indicates if the line
|
||
2 transceiver laser is ON or OFF
|
||
<Condtype> LINE_XFP_TX_OFF <Probcause>
|
||
other (1) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmsynthAlm7 5 }
|
||
|
||
|
||
|
||
pm801rrAlmLineHwFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Port HW Failure :This OID
|
||
indicates a failure on Line 2 port,
|
||
most probably caused by a HW issue
|
||
<Condtype> LINE_HW_FAIL <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
synthesisAlarm (12) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pm801rrAlmsynthAlm7 4 }
|
||
|
||
|
||
|
||
pm801rrAlmLineInitNotCompl OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Optical Module Ready :This
|
||
OID indicates the optical interface
|
||
(XFP or OTX) is not operational
|
||
|
||
<Help> This status indicates
|
||
if the line 2 transceiver has
|
||
been correctly initialized <Condtype>
|
||
LINE_INIT_NOT_COMPL <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
<Event> ObjectCDINV
|
||
"
|
||
::= { pm801rrAlmsynthAlm7 2 }
|
||
|
||
|
||
|
||
pm801rrAlmLineXfpAbsent OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Optical Module Absent :This
|
||
OID indicates the Line 2 optical
|
||
interface (XFP or OTX) is not present
|
||
in the PM <Help> This alarm indicates
|
||
if the line 2 transceiver is present.
|
||
<Condtype> LINE_XFP_ABSENT <Probcause>
|
||
inputOutputDeviceError (24) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
<Event> ObjectCDINV
|
||
"
|
||
::= { pm801rrAlmsynthAlm7 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synthAlm8 article
|
||
--- *****************************************************
|
||
pm801rrAlmsynthAlm8 OBJECT IDENTIFIER ::= { pm801rrAlmClientCrit 8 }
|
||
|
||
|
||
|
||
|
||
pm801rrAlmClientVccAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 VCC Alarm :This OID indicates
|
||
an overall VCC alarm is set over
|
||
the Line 1 XFP <Condtype> CLIENT_VCC_ALARM
|
||
<Probcause> powerProblem (36) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmsynthAlm8 15 }
|
||
|
||
|
||
|
||
pm801rrAlmClientVccWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1VCC Warning :This OID indicates
|
||
an overall VCC warning is set over
|
||
the Line 1 XFP <Condtype> CLIENT_VCC_WARNING
|
||
<Probcause> powerProblem (36) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmsynthAlm8 14 }
|
||
|
||
|
||
|
||
pm801rrAlmClientFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Port Failure :This OID
|
||
indicates a failure on the Line
|
||
1 port <Condtype> CLIENT_FAIL <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
synthesisAlarm (12) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pm801rrAlmsynthAlm8 12 }
|
||
|
||
|
||
|
||
pm801rrAlmClientDdmAlm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Alarm On Line 1 Optical Module
|
||
DDM :This OID indicates an alarm
|
||
is present coming out of Line 1
|
||
optical interface DDM <Help>
|
||
This alarm indicates if a DDM
|
||
Alarm has been detected on the
|
||
line 1 transceiver <Condtype> CLIENT_DDM_ALM
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmsynthAlm8 10 }
|
||
|
||
|
||
|
||
pm801rrAlmClientDdmWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Warning On Line 1 Optical Module
|
||
DDM :This OID indicates a warning
|
||
is present coming out of Line 1
|
||
optical interface DDM <Help>
|
||
This alarm indicates if a DDM
|
||
Warning has been detected on the
|
||
line 1 transceiver <Condtype> CLIENT_DDM_WARNING
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmsynthAlm8 9 }
|
||
|
||
|
||
|
||
pm801rrAlmClientXfpTxOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Optical Module Laser Shutdown
|
||
:This OID indicates the Line 1
|
||
optical output power is off <Help>
|
||
This status indicates if the line
|
||
1 transceiver laser is ON or OFF
|
||
<Condtype> CLIENT_XFP_TX_OFF <Probcause>
|
||
other (1) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmsynthAlm8 5 }
|
||
|
||
|
||
|
||
pm801rrAlmClientHwFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Port HW Failure :This OID
|
||
indicates a failure on Line 1 port,
|
||
most probably caused by a HW issue.
|
||
<Condtype> CLIENT_HW_FAIL <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
synthesisAlarm (12) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pm801rrAlmsynthAlm8 4 }
|
||
|
||
|
||
|
||
pm801rrAlmClientInitNotCompl OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Optical Module Ready :This
|
||
OID indicates the optical interface
|
||
(XFP or OTX) is not operational
|
||
|
||
<Help> This status indicates
|
||
if the line 1 transceiver has
|
||
been correctly initialized <Condtype>
|
||
CLIENT_INIT_NOT_COMPL <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
<Event> ObjectCDINV
|
||
"
|
||
::= { pm801rrAlmsynthAlm8 2 }
|
||
|
||
|
||
|
||
pm801rrAlmClientXfpAbsent OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Optical Module Absent :This
|
||
OID indicates the Line 1 optical
|
||
interface (XFP or OTX) is not present
|
||
in the PM <Help> This alarm indicates
|
||
if the line 1 transceiver is present.
|
||
<Condtype> CLIENT_XFP_ABSENT <Probcause>
|
||
inputOutputDeviceError (24) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
<Event> ObjectCDINV
|
||
"
|
||
::= { pm801rrAlmsynthAlm8 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientXfpAlarm1 article
|
||
--- *****************************************************
|
||
pm801rrAlmclientXfpAlarm1 OBJECT IDENTIFIER ::= { pm801rrAlmClientUrg 16 }
|
||
|
||
|
||
|
||
|
||
pm801rrAlmClientRxPwrHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Optical Rx Power High :Alarm
|
||
indicating that the Line 1 XFP/OTX
|
||
received optical power is higher
|
||
than the threshold value written
|
||
in the Line 1 XFP/OTX EEPROM <Condtype>
|
||
CLIENT_RX_PWR_HIGH_ALA <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpAlarm1 16 }
|
||
|
||
|
||
|
||
pm801rrAlmClientRxPwrLowAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Optical Rx Power Low :Alarm
|
||
indicating that the Line 1 XFP/OTX
|
||
received optical power is lower
|
||
than the threshold value written
|
||
in the Line 1 XFP/OTX EEPROM <Condtype>
|
||
CLIENT_RX_PWR_LOW_ALA <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpAlarm1 15 }
|
||
|
||
|
||
|
||
pm801rrAlmClientTempHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Transceiver Temp High :Alarm
|
||
indicating that the Line 1 XFP/OTX
|
||
temperature is higher than the
|
||
threshold value written in the
|
||
Line 1 XFP/OTX EEPROM <Condtype>
|
||
CLIENT_TEMP_HIGH_ALA <Probcause>
|
||
temperatureUnacceptable (51) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpAlarm1 8 }
|
||
|
||
|
||
|
||
pm801rrAlmClientTempLowAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Transceiver Temp Low :Alarm
|
||
indicating that the Line 1 XFP/OTX
|
||
temperature is lower than the threshold
|
||
value written in the Line 1 XFP/OTX
|
||
EEPROM <Condtype> CLIENT_TEMP_LOW_ALA
|
||
<Probcause> temperatureUnacceptable
|
||
(51) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpAlarm1 7 }
|
||
|
||
|
||
|
||
pm801rrAlmClientTxBiasHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Transceiver Bias High :Alarm
|
||
indicating that the Line 1 XFP/OTX
|
||
transmitter laser bias current
|
||
is higher than the threshold value
|
||
written in the Line 1 XFP/OTX EEPROM
|
||
<Condtype> CLIENT_TX_BIAS_HIGH_ALA
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpAlarm1 4 }
|
||
|
||
|
||
|
||
pm801rrAlmClientTxBiasLowAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Transceiver Bias Low :Alarm
|
||
indicating that the Line 1 XFP/OTX
|
||
transmitter laser bias current
|
||
is lower than the threshold value
|
||
written in the Line 1 XFP/OTX EEPROM
|
||
<Condtype> CLIENT_TX_BIAS_LOW_ALA
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpAlarm1 3 }
|
||
|
||
|
||
|
||
pm801rrAlmClientTxPwrHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Optical Tx Power High :Alarm
|
||
indicating that the Line 1 XFP/OTX
|
||
transmitter transmitter output
|
||
power is higher than the threshold
|
||
value written in the Line 1 XFP/OTX
|
||
EEPROM <Condtype> CLIENT_TX_PWR_HIGH_ALA
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpAlarm1 2 }
|
||
|
||
|
||
|
||
pm801rrAlmClientTxPwrLowAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Optical Tx Power Low :Alarm
|
||
indicating that the Line 1 XFP/OTX
|
||
transmitter transmitter output
|
||
power is lower than the threshold
|
||
value written in the Line 1 XFP/OTX
|
||
EEPROM <Condtype> CLIENT_TX_PWR_LOW_ALA
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpAlarm1 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientXfpWarnings article
|
||
--- *****************************************************
|
||
pm801rrAlmclientXfpWarnings OBJECT IDENTIFIER ::= { pm801rrAlmClientNurg 17 }
|
||
|
||
|
||
|
||
|
||
pm801rrAlmClientRxPwrHighWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Optical Rx Power High Warning
|
||
:Warning indicating that the Line
|
||
1 XFP/OTX received optical power
|
||
is higher than the threshold value
|
||
written in the Line 1 XFP/OTX EEPROM
|
||
<Condtype> CLIENT_RX_PWR_HIGH_WNG
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpWarnings 16 }
|
||
|
||
|
||
|
||
pm801rrAlmClientRxPwrLowWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Optical Rx Power Low Warning
|
||
:Warning indicating that the Line
|
||
1 XFP/OTX received optical power
|
||
is lower than the threshold value
|
||
written in the Line 1 XFP/OTX EEPROM
|
||
<Condtype> CLIENT_RX_PWR_LOW_WNG
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpWarnings 15 }
|
||
|
||
|
||
|
||
pm801rrAlmClientTempHighWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Transceiver Temp High Warning
|
||
:Warning indicating that the Line
|
||
1 XFP/OTX temperature is higher
|
||
than the threshold value written
|
||
in the Line 1 XFP/OTX EEPROM <Condtype>
|
||
CLIENT_TEMP_HIGH_WNG <Probcause>
|
||
temperatureUnacceptable (51) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpWarnings 8 }
|
||
|
||
|
||
|
||
pm801rrAlmClientTempLowWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Transceiver Temp Low Warning
|
||
:Warning indicating that the Line
|
||
1 XFP/OTX temperature is lower
|
||
than the threshold value written
|
||
in the Line 1 XFP/OTX EEPROM <Condtype>
|
||
CLIENT_TEMP_LOW_WNG <Probcause>
|
||
temperatureUnacceptable (51) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpWarnings 7 }
|
||
|
||
|
||
|
||
pm801rrAlmClientTxBiasHighWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Transceiver Bias High Warning
|
||
:Warning indicating that the Line
|
||
1 XFP/OTX transmitter laser bias
|
||
current is higher than the threshold
|
||
value written in the Line 1 XFP/OTX
|
||
EEPROM <Condtype> CLIENT_TX_BIAS_HIGH_WNG
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpWarnings 4 }
|
||
|
||
|
||
|
||
pm801rrAlmClientTxBiasLowWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Transceiver Bias Low Warning
|
||
:Warning indicating that the Line
|
||
1 XFP/OTX transmitter laser bias
|
||
current is lower than the threshold
|
||
value written in the Line 1 XFP/OTX
|
||
EEPROM <Condtype> CLIENT_TX_BIAS_LOW_WNG
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpWarnings 3 }
|
||
|
||
|
||
|
||
pm801rrAlmClientTxPwrHighWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Optical Tx Power High Warning
|
||
:Warning indicating that the Line
|
||
1 XFP/OTX transmitter transmitter
|
||
output power is higher than the
|
||
threshold value written in the
|
||
Line 1 XFP/OTX EEPROM <Condtype>
|
||
CLIENT_TX_PWR_HIGH_WNG <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpWarnings 2 }
|
||
|
||
|
||
|
||
pm801rrAlmClientTxPwrLowWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Optical Tx Power Low Warning
|
||
:Warning indicating that the Line
|
||
1 XFP/OTX transmitter transmitter
|
||
output power is lower than the
|
||
threshold value written in the
|
||
Line 1 XFP/OTX EEPROM <Condtype>
|
||
CLIENT_TX_PWR_LOW_WNG <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpWarnings 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientXfpAlarms2 article
|
||
--- *****************************************************
|
||
pm801rrAlmclientXfpAlarms2 OBJECT IDENTIFIER ::= { pm801rrAlmClientCrit 19 }
|
||
|
||
|
||
|
||
|
||
pm801rrAlmClientApdSupplyFault OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Rx Photodiode Power Failed
|
||
:This OID indicates a failure on
|
||
the Line 1 APD power supply <Condtype>
|
||
CLIENT_APD_SUPPLY_FAULT <Probcause>
|
||
receiverFailure (42) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpAlarms2 16 }
|
||
|
||
|
||
|
||
pm801rrAlmClientTecFault OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Optical Tx Temp Regul.
|
||
Failed :This OID indicates a failure
|
||
on the Line 1 TEC module <Condtype>
|
||
CLIENT_TEC_FAULT <Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpAlarms2 15 }
|
||
|
||
|
||
|
||
pm801rrAlmClientWavelengthUnlocked OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Optical Tx Wavelength Unlocked
|
||
:This OID indicates that the Line
|
||
1 wavelength error is exceeding
|
||
the manufacturer tolerance <Condtype>
|
||
CLIENT_WAVELENGTH_UNLOCKED <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpAlarms2 14 }
|
||
|
||
|
||
|
||
pm801rrAlmClientChannelNotAcquired OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 DWDM Channel Not Acquired
|
||
:This OID indicates the transceiver
|
||
didn't tune the DWDM Channel succesfully.
|
||
<Help> This status indicates
|
||
the transceiver has not tuned
|
||
the DWDM Channel succesfully.
|
||
<Condtype> CLIENT_CHANNEL_NOT_ACQUIRED
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpAlarms2 10 }
|
||
|
||
|
||
|
||
pm801rrAlmClientTxNr OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Optical Tx Not Ready :This
|
||
OID indicates a condition has arisen
|
||
leading to invalid data on the
|
||
Line 1 transmitting side <Condtype>
|
||
CLIENT_TX_NR <Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpAlarms2 8 }
|
||
|
||
|
||
|
||
pm801rrAlmClientTxFault OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Optical Tx Failure :This
|
||
OID indicates a fault condition
|
||
on the Line 1 laser detected by
|
||
the safety syste <Condtype> CLIENT_TX_FAULT
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpAlarms2 7 }
|
||
|
||
|
||
|
||
pm801rrAlmClientTxCdrNotLocked OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Optical Tx CDR Unlocked
|
||
:This OID indicates a loss of lock
|
||
on the Line 1 transmitting side
|
||
CDR has been detected. <Condtype>
|
||
CLIENT_TX_CDR_NOT_LOCKED <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpAlarms2 6 }
|
||
|
||
|
||
|
||
pm801rrAlmClientRxNr OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Optical Rx Not Ready :This
|
||
OID indicates that a condition
|
||
has arisen leading to invalid
|
||
data on the Line 1 receiving side.
|
||
<Condtype> CLIENT_RX_NR <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpAlarms2 5 }
|
||
|
||
|
||
|
||
pm801rrAlmClientRxLos OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Loss Of Optical Signal
|
||
:This bit indicates an absence
|
||
of signal on the XFP/OTX <Help>
|
||
This alarm indicates if an optical
|
||
signal is detected on the line
|
||
1 transceiver input <Condtype>
|
||
CLIENT_RX_LOS <Probcause> receiveFailure
|
||
(41) <Alarmtype> physicalViolation
|
||
(9) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpAlarms2 4 }
|
||
|
||
|
||
|
||
pm801rrAlmClientRxCdrNotLocked OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Optical Rx CDR Unlocked
|
||
:This OID indicates that a loss
|
||
of lock on the Line 1 receiving
|
||
side CDR has been detected <Condtype>
|
||
CLIENT_RX_CDR_NOT_LOCKED <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpAlarms2 3 }
|
||
|
||
|
||
|
||
pm801rrAlmClientResetComplete OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Not Used :This bit indicates that
|
||
the internal reset process is completed
|
||
and the data are available <Condtype>
|
||
CLIENT_RESET_COMPLETE <Probcause>
|
||
other (1) <Alarmtype> other (1)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientXfpAlarms2 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientOtxTlhAlarms3 article
|
||
--- *****************************************************
|
||
pm801rrAlmclientOtxTlhAlarms3 OBJECT IDENTIFIER ::= { pm801rrAlmClientUrg 22 }
|
||
|
||
|
||
|
||
|
||
pm801rrAlmClientLaserTempHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Laser Temp. High Alarm
|
||
:Alarm indicating the Line 1 OTX
|
||
TLH laser temperature is higher
|
||
than the threshold written in the
|
||
EEPROM <Condtype> CLIENT_LASER_TEMP_HIGH_ALA
|
||
<Probcause> temperatureUnacceptable
|
||
(51) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientOtxTlhAlarms3 14 }
|
||
|
||
|
||
|
||
pm801rrAlmClientFreqDevHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Freq. Deviation High Alarm
|
||
:Alarm indicating the Line 1 OTX
|
||
TLH frequency deviation is higher
|
||
than the threshold written in the
|
||
EEPROM <Condtype> CLIENT_FREQ_DEV_HIGH_ALA
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientOtxTlhAlarms3 12 }
|
||
|
||
|
||
|
||
pm801rrAlmClientCdrNotReady OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 CDR Not Ready :This OID
|
||
indicates the Clock Data Recovery
|
||
unit is not yet initialized
|
||
<Help> This alarm indicates
|
||
the Clock Data Recovery unit is
|
||
not yet initialized. <Condtype>
|
||
CLIENT_CDR_NOT_READY <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientOtxTlhAlarms3 9 }
|
||
|
||
|
||
|
||
pm801rrAlmClientAgingHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 OTX TLH Aging High Alarm
|
||
:Alarm indicating the Line 1 OTX
|
||
TLH aging is higher than the threshold
|
||
written in the EEPROM <Condtype>
|
||
CLIENT_AGING_HIGH_ALA <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientOtxTlhAlarms3 6 }
|
||
|
||
|
||
|
||
pm801rrAlmClientModulatorAgingHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Modulator Aging High Alarm
|
||
:Alarm indicating the Line 1 OTX
|
||
TLH modulator aging is higher than
|
||
the threshold written in the EEPROM
|
||
<Condtype> CLIENT_MODULATOR_AGING_HIGH_ALA
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientOtxTlhAlarms3 5 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientOtxTlhWarnings article
|
||
--- *****************************************************
|
||
pm801rrAlmclientOtxTlhWarnings OBJECT IDENTIFIER ::= { pm801rrAlmClientNurg 23 }
|
||
|
||
|
||
|
||
|
||
pm801rrAlmClientLaserTempHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Laser Temp. High Warning
|
||
:Warning indicating the Line 1
|
||
OTX TLH laser temperature is higher
|
||
than the threshold written in the
|
||
EEPROM <Condtype> CLIENT_LASER_TEMP_HIGH_WARNING
|
||
<Probcause> temperatureUnacceptable
|
||
(51) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientOtxTlhWarnings 14 }
|
||
|
||
|
||
|
||
pm801rrAlmClientFreqDevHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Freq. Deviation High Warning
|
||
:Warning indicating the Line 1
|
||
OTX TLH frequency deviation is
|
||
higher than the threshold written
|
||
in the EEPROM <Condtype> CLIENT_FREQ_DEV_HIGH_WARNING
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientOtxTlhWarnings 12 }
|
||
|
||
|
||
|
||
pm801rrAlmClientAgingHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 OTX TLH Aging High Warning
|
||
:Warning indicating the Line 1
|
||
OTX TLH aging is higher than the
|
||
threshold written in the EEPROM
|
||
<Condtype> CLIENT_AGING_HIGH_WARNING
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientOtxTlhWarnings 6 }
|
||
|
||
|
||
|
||
pm801rrAlmClientModulatorAgingHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Modulator Aging High Warning
|
||
:Warning indicating the Line 1
|
||
OTX TLH modulator aging is higher
|
||
than the threshold written in the
|
||
EEPROM <Condtype> CLIENT_MODULATOR_AGING_HIGH_WARNING
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmclientOtxTlhWarnings 5 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineXfpAlarm1 article
|
||
--- *****************************************************
|
||
pm801rrAlmlineXfpAlarm1 OBJECT IDENTIFIER ::= { pm801rrAlmLineUrg 24 }
|
||
|
||
|
||
|
||
|
||
pm801rrAlmLineRxPwrHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Optical Rx Power High :Alarm
|
||
indicating that the Line 2 XFP/OTX
|
||
received optical power is higher
|
||
than the threshold value written
|
||
in the Line 2 XFP/OTX EEPROM <Condtype>
|
||
LINE_RX_PWR_HIGH_ALA <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpAlarm1 16 }
|
||
|
||
|
||
|
||
pm801rrAlmLineRxPwrLowAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Optical Rx Power Low :Alarm
|
||
indicating that the Line 2 XFP/OTX
|
||
received optical power is lower
|
||
than the threshold value written
|
||
in the Line 2 XFP/OTX EEPROM <Condtype>
|
||
LINE_RX_PWR_LOW_ALA <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpAlarm1 15 }
|
||
|
||
|
||
|
||
pm801rrAlmLineTempHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Transceiver Temp High :Alarm
|
||
indicating that the Line 2 XFP/OTX
|
||
temperature is higher than the
|
||
threshold value written in the
|
||
Line 2 XFP/OTX EEPROM <Condtype>
|
||
LINE_TEMP_HIGH_ALA <Probcause>
|
||
temperatureUnacceptable (51) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpAlarm1 8 }
|
||
|
||
|
||
|
||
pm801rrAlmLineTempLowAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Transceiver Temp Low :Alarm
|
||
indicating that the Line 2 XFP/OTX
|
||
temperature is lower than the threshold
|
||
value written in the Line 2 XFP/OTX
|
||
EEPROM <Condtype> LINE_TEMP_LOW_ALA
|
||
<Probcause> temperatureUnacceptable
|
||
(51) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpAlarm1 7 }
|
||
|
||
|
||
|
||
pm801rrAlmLineTxBiasHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Transceiver Bias High :Alarm
|
||
indicating that the Line 2 XFP/OTX
|
||
transmitter laser bias current
|
||
is higher than the threshold value
|
||
written in the Line 2 XFP/OTX EEPROM
|
||
<Condtype> LINE_TX_BIAS_HIGH_ALA
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpAlarm1 4 }
|
||
|
||
|
||
|
||
pm801rrAlmLineTxBiasLowAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Transceiver Bias Low :Alarm
|
||
indicating that the Line 2 XFP/OTX
|
||
transmitter laser bias current
|
||
is lower than the threshold value
|
||
written in the Line 2 XFP/OTX EEPROM
|
||
<Condtype> LINE_TX_BIAS_LOW_ALA
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpAlarm1 3 }
|
||
|
||
|
||
|
||
pm801rrAlmLineTxPwrHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Optical Tx Power High :Alarm
|
||
indicating that the Line 2 XFP/OTX
|
||
transmitter transmitter output
|
||
power is higher than the threshold
|
||
value written in the Line 2 XFP/OTX
|
||
EEPROM <Condtype> LINE_TX_PWR_HIGH_ALA
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpAlarm1 2 }
|
||
|
||
|
||
|
||
pm801rrAlmLineTxPwrLowAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Optical Tx Power Low :Alarm
|
||
indicating that the Line 2 XFP/OTX
|
||
transmitter transmitter output
|
||
power is lower than the threshold
|
||
value written in the Line 2 XFP/OTX
|
||
EEPROM <Condtype> LINE_TX_PWR_LOW_ALA
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpAlarm1 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineXfpWarnings article
|
||
--- *****************************************************
|
||
pm801rrAlmlineXfpWarnings OBJECT IDENTIFIER ::= { pm801rrAlmLineNurg 25 }
|
||
|
||
|
||
|
||
|
||
pm801rrAlmLineRxPwrHighWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Optical Rx Power High Warning
|
||
:Warning indicating that the Line
|
||
2 XFP/OTX received optical power
|
||
is higher than the threshold value
|
||
written in the Line 2 XFP/OTX EEPROM
|
||
<Condtype> LINE_RX_PWR_HIGH_WNG
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpWarnings 16 }
|
||
|
||
|
||
|
||
pm801rrAlmLineRxPwrLowWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Optical Rx Power Low Warning
|
||
:Warning indicating that the Line
|
||
2 XFP/OTX received optical power
|
||
is lower than the threshold value
|
||
written in the Line 2 XFP/OTX EEPROM
|
||
<Condtype> LINE_RX_PWR_LOW_WNG
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpWarnings 15 }
|
||
|
||
|
||
|
||
pm801rrAlmLineTempHighWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Transceiver Temp High Warning
|
||
:Warning indicating that the Line
|
||
2 XFP/OTX temperature is higher
|
||
than the threshold value written
|
||
in the Line 2 XFP/OTX EEPROM <Condtype>
|
||
LINE_TEMP_HIGH_WNG <Probcause>
|
||
temperatureUnacceptable (51) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpWarnings 8 }
|
||
|
||
|
||
|
||
pm801rrAlmLineTempLowWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Transceiver Temp Low Warning
|
||
:Warning indicating that the Line
|
||
2 XFP/OTX temperature is lower
|
||
than the threshold value written
|
||
in the Line 2 XFP/OTX EEPROM <Condtype>
|
||
LINE_TEMP_LOW_WNG <Probcause> temperatureUnacceptable
|
||
(51) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpWarnings 7 }
|
||
|
||
|
||
|
||
pm801rrAlmLineTxBiasHighWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Transceiver Bias High Warning
|
||
:Warning indicating that the Line
|
||
2 XFP/OTX transmitter laser bias
|
||
current is higher than the threshold
|
||
value written in the Line 2 XFP/OTX
|
||
EEPROM <Condtype> LINE_TX_BIAS_HIGH_WNG
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpWarnings 4 }
|
||
|
||
|
||
|
||
pm801rrAlmLineTxBiasLowWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Transceiver Bias Low Warning
|
||
:Warning indicating that the Line
|
||
2 XFP/OTX transmitter laser bias
|
||
current is lower than the threshold
|
||
value written in the Line 2 XFP/OTX
|
||
EEPROM <Condtype> LINE_TX_BIAS_LOW_WNG
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpWarnings 3 }
|
||
|
||
|
||
|
||
pm801rrAlmLineTxPwrHighWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Optical Tx Power High Warning
|
||
:Warning indicating that the Line
|
||
2 XFP/OTX transmitter transmitter
|
||
output power is higher than the
|
||
threshold value written in the
|
||
Line 2 XFP/OTX EEPROM <Condtype>
|
||
LINE_TX_PWR_HIGH_WNG <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpWarnings 2 }
|
||
|
||
|
||
|
||
pm801rrAlmLineTxPwrLowWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Optical Tx Power Low Warning
|
||
:Warning indicating that the Line
|
||
2 XFP/OTX transmitter transmitter
|
||
output power is lower than the
|
||
threshold value written in the
|
||
Line 2 XFP/OTX EEPROM <Condtype>
|
||
LINE_TX_PWR_LOW_WNG <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpWarnings 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineXfpAlarms2 article
|
||
--- *****************************************************
|
||
pm801rrAlmlineXfpAlarms2 OBJECT IDENTIFIER ::= { pm801rrAlmLineCrit 27 }
|
||
|
||
|
||
|
||
|
||
pm801rrAlmLineApdSupplyFault OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Rx Photodiode Power Failed
|
||
:This OID indicates a failure on
|
||
the Line 2 APD power supply <Condtype>
|
||
LINE_APD_SUPPLY_FAULT <Probcause>
|
||
receiverFailure (42) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpAlarms2 16 }
|
||
|
||
|
||
|
||
pm801rrAlmLineTecFault OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Optical Tx Temp Regul.
|
||
Failed :This OID indicates a failure
|
||
on the Line 2 TEC module <Condtype>
|
||
LINE_TEC_FAULT <Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpAlarms2 15 }
|
||
|
||
|
||
|
||
pm801rrAlmLineWavelengthUnlocked OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Optical Tx Wavelength Unlocked
|
||
:This OID indicates that the Line
|
||
2 wavelength error is exceeding
|
||
the manufacturer tolerance <Condtype>
|
||
LINE_WAVELENGTH_UNLOCKED <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpAlarms2 14 }
|
||
|
||
|
||
|
||
pm801rrAlmLineChannelNotAcquired OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 DWDM Channel Not Acquired
|
||
:This OID indicates the transceiver
|
||
didn't tune the DWDM Channel succesfully.
|
||
<Help> This status indicates
|
||
the transceiver has not tuned
|
||
the DWDM Channel succesfully.
|
||
<Condtype> LINE_CHANNEL_NOT_ACQUIRED
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpAlarms2 10 }
|
||
|
||
|
||
|
||
pm801rrAlmLineTxNr OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Optical Tx Not Ready :This
|
||
OID indicates a condition has arisen
|
||
leading to invalid data on the
|
||
Line 2 transmitting side <Condtype>
|
||
LINE_TX_NR <Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpAlarms2 8 }
|
||
|
||
|
||
|
||
pm801rrAlmLineTxFault OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Optical Tx Failure :This
|
||
OID indicates a fault condition
|
||
on the Line 2 laser detected by
|
||
the safety syste <Condtype> LINE_TX_FAULT
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpAlarms2 7 }
|
||
|
||
|
||
|
||
pm801rrAlmLineTxCdrNotLocked OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Optical Tx CDR Unlocked
|
||
:This OID indicates a loss of lock
|
||
on the Line 2 transmitting side
|
||
CDR has been detected. <Condtype>
|
||
LINE_TX_CDR_NOT_LOCKED <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpAlarms2 6 }
|
||
|
||
|
||
|
||
pm801rrAlmLineRxNr OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Optical Rx Not Ready :This
|
||
OID indicates that a condition
|
||
has arisen leading to invalid
|
||
data on the Line 2 receiving side.
|
||
<Condtype> LINE_RX_NR <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpAlarms2 5 }
|
||
|
||
|
||
|
||
pm801rrAlmLineRxLos OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Loss Of Optical Signal
|
||
:This bit indicates an absence
|
||
of signal on the XFP/OTX <Help>
|
||
This alarm indicates if an optical
|
||
signal is detected on the line
|
||
2 transceiver input <Condtype>
|
||
LINE_RX_LOS <Probcause> receiveFailure
|
||
(41) <Alarmtype> physicalViolation
|
||
(9) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpAlarms2 4 }
|
||
|
||
|
||
|
||
pm801rrAlmLineRxCdrNotLocked OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Optical Rx CDR Unlocked
|
||
:This OID indicates that a loss
|
||
of lock on the Line 2 receiving
|
||
side CDR has been detected <Condtype>
|
||
LINE_RX_CDR_NOT_LOCKED <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpAlarms2 3 }
|
||
|
||
|
||
|
||
pm801rrAlmLineResetComplete OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Not Used :This bit indicates that
|
||
the internal reset process is completed
|
||
and the data are available <Condtype>
|
||
LINE_RESET_COMPLETE <Probcause>
|
||
other (1) <Alarmtype> other (1)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmlineXfpAlarms2 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the rrLineOtxTlhAlarms3 article
|
||
--- *****************************************************
|
||
pm801rrAlmrrLineOtxTlhAlarms3 OBJECT IDENTIFIER ::= { pm801rrAlmLineUrg 30 }
|
||
|
||
|
||
|
||
|
||
pm801rrAlmLineLaserTempHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Laser Temp. High Alarm
|
||
:Alarm indicating the Line 2 OTX
|
||
TLH laser temperature is higher
|
||
than the threshold written in the
|
||
EEPROM <Condtype> LINE_LASER_TEMP_HIGH_ALA
|
||
<Probcause> temperatureUnacceptable
|
||
(51) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmrrLineOtxTlhAlarms3 14 }
|
||
|
||
|
||
|
||
pm801rrAlmLineFreqDevHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Freq. Deviation High Alarm
|
||
:Alarm indicating the Line 2 OTX
|
||
TLH frequency deviation is higher
|
||
than the threshold written in the
|
||
EEPROM <Condtype> LINE_FREQ_DEV_HIGH_ALA
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmrrLineOtxTlhAlarms3 12 }
|
||
|
||
|
||
|
||
pm801rrAlmLineCdrNotReady OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 CDR Not Ready :This OID
|
||
indicates the Clock Data Recovery
|
||
unit is not yet initialized
|
||
<Help> This alarm indicates
|
||
the Clock Data Recovery unit is
|
||
not yet initialized. <Condtype>
|
||
LINE_CDR_NOT_READY <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmrrLineOtxTlhAlarms3 9 }
|
||
|
||
|
||
|
||
pm801rrAlmLineAgingHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 OTX TLH Aging High Alarm
|
||
:Alarm indicating the Line 2 OTX
|
||
TLH aging is higher than the threshold
|
||
written in the EEPROM <Condtype>
|
||
LINE_AGING_HIGH_ALA <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmrrLineOtxTlhAlarms3 6 }
|
||
|
||
|
||
|
||
pm801rrAlmLineModulatorAgingHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Modulator Aging High Alarm
|
||
:Alarm indicating the Line 2 OTX
|
||
TLH modulator aging is higher than
|
||
the threshold written in the EEPROM
|
||
<Condtype> LINE_MODULATOR_AGING_HIGH_ALA
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmrrLineOtxTlhAlarms3 5 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the rrLineOtxTlhWarnings article
|
||
--- *****************************************************
|
||
pm801rrAlmrrLineOtxTlhWarnings OBJECT IDENTIFIER ::= { pm801rrAlmLineNurg 31 }
|
||
|
||
|
||
|
||
|
||
pm801rrAlmLineLaserTempHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Laser Temp. High Warning
|
||
:Warning indicating the Line 2
|
||
OTX TLH laser temperature is higher
|
||
than the threshold written in the
|
||
EEPROM <Condtype> LINE_LASER_TEMP_HIGH_WARNING
|
||
<Probcause> temperatureUnacceptable
|
||
(51) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmrrLineOtxTlhWarnings 14 }
|
||
|
||
|
||
|
||
pm801rrAlmLineFreqDevHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Freq. Deviation High Warning
|
||
:Warning indicating the Line 2
|
||
OTX TLH frequency deviation is
|
||
higher than the threshold written
|
||
in the EEPROM <Condtype> LINE_FREQ_DEV_HIGH_WARNING
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmrrLineOtxTlhWarnings 12 }
|
||
|
||
|
||
|
||
pm801rrAlmLineAgingHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 OTX TLH Aging High Warning
|
||
:Warning indicating the Line 2
|
||
OTX TLH aging is higher than the
|
||
threshold written in the EEPROM
|
||
<Condtype> LINE_AGING_HIGH_WARNING
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmrrLineOtxTlhWarnings 6 }
|
||
|
||
|
||
|
||
pm801rrAlmLineModulatorAgingHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Modulator Aging High Warning
|
||
:Warning indicating the Line 2
|
||
OTX TLH modulator aging is higher
|
||
than the threshold written in the
|
||
EEPROM <Condtype> LINE_MODULATOR_AGING_HIGH_WARNING
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm801rrAlmrrLineOtxTlhWarnings 5 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- CONTROLS
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synth0 article
|
||
--- *****************************************************
|
||
pm801rrCtrlsynth0 OBJECT IDENTIFIER ::= { pm801rrCtrlOther 0 }
|
||
|
||
|
||
|
||
|
||
pm801rrCtrlConfClear OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Clear Configuration Tables :This
|
||
bit clears the configuration tables
|
||
from configuration in the flash.
|
||
<Help> This control restores
|
||
the default configuration of the
|
||
module
|
||
"
|
||
::= { pm801rrCtrlsynth0 13 }
|
||
|
||
|
||
|
||
pm801rrCtrlConfFlash OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Write Configuration Tables :This
|
||
bit saves the current configuration
|
||
of the module as configuration
|
||
in the flash. <Help> This control
|
||
saves the customer configuration
|
||
on the module
|
||
"
|
||
::= { pm801rrCtrlsynth0 9 }
|
||
|
||
|
||
|
||
pm801rrCtrlConfLoad OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Load Configuration Tables :When
|
||
set this enables loading from flash
|
||
configuration1 into the module.
|
||
"
|
||
::= { pm801rrCtrlsynth0 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synth4 article
|
||
--- *****************************************************
|
||
pm801rrCtrlsynth4 OBJECT IDENTIFIER ::= { pm801rrCtrlOther 4 }
|
||
|
||
|
||
|
||
|
||
pm801rrCtrlCorrelatOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Disable Alarm Correlation :This
|
||
OID disables the alarm correlation
|
||
in the PM
|
||
"
|
||
::= { pm801rrCtrlsynth4 2 }
|
||
|
||
|
||
|
||
pm801rrCtrlCorrelatOn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Enable Alarm Correlation :This
|
||
OID enables the alarm correlation
|
||
in the PM
|
||
"
|
||
::= { pm801rrCtrlsynth4 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the swMgnt article
|
||
--- *****************************************************
|
||
pm801rrCtrlswMgnt OBJECT IDENTIFIER ::= { pm801rrCtrlOther 5 }
|
||
|
||
|
||
|
||
|
||
pm801rrCtrlWarmReset OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Software Warm Reset :This OID,
|
||
when set, causes a warm reset of
|
||
the Software. This reset is not
|
||
traffic affecting, and the configuration
|
||
of the Sofwtare remains unchanged.
|
||
<Help> This control initiates
|
||
a warm reset of the module.
|
||
"
|
||
::= { pm801rrCtrlswMgnt 3 }
|
||
|
||
|
||
|
||
pm801rrCtrlColdReset OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Software Cold Reset :This OID,
|
||
when set, causes a cold reset of
|
||
the Software. This reset is traffic
|
||
affecting, and the configuration
|
||
of Software is reloaded on start-up.
|
||
<Help> This control initiates
|
||
a cold reset of the module.
|
||
"
|
||
::= { pm801rrCtrlswMgnt 2 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientXfpOnoff article
|
||
--- *****************************************************
|
||
pm801rrCtrlclientXfpOnoff OBJECT IDENTIFIER ::= { pm801rrCtrlClient 16 }
|
||
|
||
|
||
|
||
|
||
pm801rrCtrlClientXfpOnoff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
XFP/OTX Laser Shut Down :This
|
||
OID switches off the Line 1 XFP/OTX
|
||
<Help> This control defines the
|
||
laser state of the line 1 transceiver
|
||
"
|
||
::= { pm801rrCtrlclientXfpOnoff 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientXfpLineLoop article
|
||
--- *****************************************************
|
||
pm801rrCtrlclientXfpLineLoop OBJECT IDENTIFIER ::= { pm801rrCtrlClient 17 }
|
||
|
||
|
||
|
||
|
||
pm801rrCtrlClientXfpLineLoop OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
XFP/OTX Loop :This OID operates
|
||
a loopback on the Line 1 XFP/OTX
|
||
<Help> This control defines the
|
||
line loop back of the line 1 transceiver
|
||
"
|
||
::= { pm801rrCtrlclientXfpLineLoop 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientXfiLoop article
|
||
--- *****************************************************
|
||
pm801rrCtrlclientXfiLoop OBJECT IDENTIFIER ::= { pm801rrCtrlClient 18 }
|
||
|
||
|
||
|
||
|
||
pm801rrCtrlClientXfiLoop OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
XFP/OTX XFI Loop :This OID operates
|
||
a XFI loopback on the Line 1 XFP/OTX
|
||
<Help> This control defines
|
||
the XFI loop back of the line
|
||
transceiver
|
||
"
|
||
::= { pm801rrCtrlclientXfiLoop 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientTunableChannel article
|
||
--- *****************************************************
|
||
|
||
pm801rrCtrlclientTunableChannel OBJECT-TYPE
|
||
SYNTAX Pm801rrOtxChannel
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
ITU Channel :This OID selects
|
||
the ITU channel of the Line 1
|
||
OTX TLH Laser <Help> This control
|
||
defines the ITU channel of the
|
||
Line 1 OTX TLH Laser
|
||
"
|
||
::= { pm801rrCtrlClient 19 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientPhotodiodeMode article
|
||
--- *****************************************************
|
||
|
||
pm801rrCtrlclientPhotodiodeMode OBJECT-TYPE
|
||
SYNTAX Pm801rrOtxMode
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
OTX TLH Rx Sens. Mode :This OID
|
||
defines the Rx sensiblity mode
|
||
of the Line 1 OTX TLH <Help>
|
||
This control defines the receiver
|
||
sensibility mode of the Line 1
|
||
OTX TLH Laser (OTX60, OTX80 or
|
||
Custom)
|
||
"
|
||
::= { pm801rrCtrlClient 20 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientPhotodiodeValue article
|
||
--- *****************************************************
|
||
|
||
pm801rrCtrlclientPhotodiodeValue OBJECT-TYPE
|
||
SYNTAX Pm801rrAdjustValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
OTX TLH Rx Sensibility :This OID
|
||
sets the Rx sensibility of the
|
||
Line 1 OTX TLH (custom mode only)
|
||
<Help> This control defines
|
||
the receiver sensibility value
|
||
(only in Custom mode) of the Line
|
||
1 OTX TLH Laser
|
||
"
|
||
::= { pm801rrCtrlClient 21 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientPowerLaser article
|
||
--- *****************************************************
|
||
|
||
pm801rrCtrlclientPowerLaser OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Laser Output Power [3-5] :This
|
||
OID sets the output power value
|
||
on the laser of the Line 1 OTX
|
||
TLH (AV=Power*10+158) (Unit =
|
||
dBm) <Help> This control defines
|
||
the start-up output power of the
|
||
Line 1 OTX TLH
|
||
"
|
||
::= { pm801rrCtrlClient 22 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientOtxVlhReset article
|
||
--- *****************************************************
|
||
pm801rrCtrlclientOtxVlhReset OBJECT IDENTIFIER ::= { pm801rrCtrlLine 23 }
|
||
|
||
|
||
|
||
|
||
pm801rrCtrlClientOtxVlhReset OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
OTX-VLH Reset :This OID resets
|
||
the OTX-VLH module <Help> This
|
||
control resets the OTX-TLH and
|
||
its parameters
|
||
"
|
||
::= { pm801rrCtrlclientOtxVlhReset 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineXfpOnoff article
|
||
--- *****************************************************
|
||
pm801rrCtrllineXfpOnoff OBJECT IDENTIFIER ::= { pm801rrCtrlLine 24 }
|
||
|
||
|
||
|
||
|
||
pm801rrCtrlLineXfpOnoff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
XFP/OTX Laser Shut Down :This
|
||
OID switches off the Line 2 XFP/OTX
|
||
<Help> This control defines the
|
||
laser state of the line 2 transceiver
|
||
"
|
||
::= { pm801rrCtrllineXfpOnoff 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineXfpLineLoop article
|
||
--- *****************************************************
|
||
pm801rrCtrllineXfpLineLoop OBJECT IDENTIFIER ::= { pm801rrCtrlLine 25 }
|
||
|
||
|
||
|
||
|
||
pm801rrCtrlLineXfpLineLoop OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
XFP/OTX Loop :This OID operates
|
||
a loopback on the Line 2 XFP/OTX
|
||
<Help> This control defines the
|
||
line loop back of the line 2 transceiver
|
||
"
|
||
::= { pm801rrCtrllineXfpLineLoop 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineXfiLoop article
|
||
--- *****************************************************
|
||
pm801rrCtrllineXfiLoop OBJECT IDENTIFIER ::= { pm801rrCtrlLine 26 }
|
||
|
||
|
||
|
||
|
||
pm801rrCtrlLineXfiLoop OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
XFP/OTX XFI Loop :This OID operates
|
||
a XFI loopback on the Line 2 XFP/OTX
|
||
<Help> This control defines
|
||
the XFI loop back of the line
|
||
2 transceiver
|
||
"
|
||
::= { pm801rrCtrllineXfiLoop 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineTunableChannel article
|
||
--- *****************************************************
|
||
|
||
pm801rrCtrllineTunableChannel OBJECT-TYPE
|
||
SYNTAX Pm801rrOtxChannel
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
ITU Channel :This OID selects
|
||
the ITU channel of the Line 2
|
||
OTX TLH Laser <Help> This control
|
||
defines the ITU channel of the
|
||
Line 2 OTX TLH Laser
|
||
"
|
||
::= { pm801rrCtrlLine 27 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the linePhotodiodeMode article
|
||
--- *****************************************************
|
||
|
||
pm801rrCtrllinePhotodiodeMode OBJECT-TYPE
|
||
SYNTAX Pm801rrOtxMode
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
OTX TLH Rx Sens. Mode :This OID
|
||
defines the Rx sensiblity mode
|
||
of the Line 2 OTX TLH <Help>
|
||
This control defines the receiver
|
||
sensibility mode of the Line 2
|
||
OTX TLH Laser (OTX60, OTX80 or
|
||
Custom)
|
||
"
|
||
::= { pm801rrCtrlLine 28 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the linePhotodiodeValue article
|
||
--- *****************************************************
|
||
|
||
pm801rrCtrllinePhotodiodeValue OBJECT-TYPE
|
||
SYNTAX Pm801rrAdjustValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
OTX TLH Rx Sensibility :This OID
|
||
sets the Rx sensibility of the
|
||
Line 2 OTX TLH (custom mode only)
|
||
<Help> This control defines
|
||
the receiver sensibility value
|
||
(only in Custom mode) of the Line
|
||
2 OTX TLH Laser
|
||
"
|
||
::= { pm801rrCtrlLine 29 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the linePowerLaser article
|
||
--- *****************************************************
|
||
|
||
pm801rrCtrllinePowerLaser OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Laser Output Power [3-5] :This
|
||
OID sets the output power value
|
||
on the laser of the Line 2 OTX
|
||
TLH (AV=Power*10+158) (Unit =
|
||
dBm) <Help> This control defines
|
||
the start-up output power of the
|
||
Line 2 OTX TLH
|
||
"
|
||
::= { pm801rrCtrlLine 30 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineOtxVlhReset article
|
||
--- *****************************************************
|
||
pm801rrCtrllineOtxVlhReset OBJECT IDENTIFIER ::= { pm801rrCtrlLine 31 }
|
||
|
||
|
||
|
||
|
||
pm801rrCtrlLineOtxVlhReset OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
OTX-VLH Reset :This OID resets
|
||
the OTX-VLH module <Help> This
|
||
control resets the OTX-TLH and
|
||
its parameters
|
||
"
|
||
::= { pm801rrCtrllineOtxVlhReset 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the ledTest article
|
||
--- *****************************************************
|
||
pm801rrCtrlledTest OBJECT IDENTIFIER ::= { pm801rrCtrlOther 64 }
|
||
|
||
|
||
|
||
|
||
pm801rrCtrlLedOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Leds Off :This OID switches off
|
||
all the Leds as a test feature.
|
||
<Help> This control initiates
|
||
a test leds turning all the LEDs
|
||
to OFF
|
||
"
|
||
::= { pm801rrCtrlledTest 3 }
|
||
|
||
|
||
|
||
pm801rrCtrlRedLed OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Red Leds Test :This OID switches
|
||
on all the red Leds as a test feature.
|
||
<Help> This control initiates
|
||
a test leds turning all the LEDs
|
||
to red
|
||
"
|
||
::= { pm801rrCtrlledTest 2 }
|
||
|
||
|
||
|
||
pm801rrCtrlGreenLed OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Green Leds Test :This OID switches
|
||
on all the green Leds as a test
|
||
feature. <Help> This control
|
||
initiates a test leds turning
|
||
all the LEDs to green
|
||
"
|
||
::= { pm801rrCtrlledTest 1 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- MEASURES
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientTemperature article
|
||
--- *****************************************************
|
||
|
||
pm801rrMesrclientTemperature OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Optical Module Temperature
|
||
:This OID gives the temperature
|
||
of the Client XFP/OTX, read from
|
||
the DDM (Digital Diagnostic Monitoring)
|
||
(Temperature = AV/256) (Unit =
|
||
C) <Help> This measure gives
|
||
the temperature of the line 1
|
||
transceiver
|
||
"
|
||
::= { pm801rrMesrClient 16 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientTxBias article
|
||
--- *****************************************************
|
||
|
||
pm801rrMesrclientTxBias OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 XFP/OTX Tx Bias Current
|
||
:This OID gives the bias value
|
||
of the Client XFP/OTX, read from
|
||
the DDM (Digital Diagnostic Monitoring)
|
||
(Bias = AV/500) (Unit = mA) <Help>
|
||
This measure gives the bias of
|
||
the line 1 transceiver
|
||
"
|
||
::= { pm801rrMesrClient 18 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientTxPower article
|
||
--- *****************************************************
|
||
|
||
pm801rrMesrclientTxPower OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Optical Module Tx Power
|
||
:This OID gives the transmit power
|
||
value of the Client XFP/OTX, read
|
||
from the DDM (Digital Diagnostic
|
||
Monitoring) (Power = 10*log(AV)-40)
|
||
(Unit = dBm) <Help> This measure
|
||
gives the Tx optical power of the
|
||
line 1 transceiver
|
||
"
|
||
::= { pm801rrMesrClient 19 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientRxPower article
|
||
--- *****************************************************
|
||
|
||
pm801rrMesrclientRxPower OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Optical Module Rx Power
|
||
:This OID gives the receive power
|
||
value of the Client XFP/OTX, read
|
||
from the DDM (Digital Diagnostic
|
||
Monitoring) (Power = 10*log(AV)-40)
|
||
(Unit = dBm) <Help> This measure
|
||
gives the Rx optical power of the
|
||
line 1 transceiver
|
||
"
|
||
::= { pm801rrMesrClient 20 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineTemperature article
|
||
--- *****************************************************
|
||
|
||
pm801rrMesrlineTemperature OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Optical Module Temperature
|
||
:This OID gives the temperature
|
||
of the Line XFP/OTX, read from
|
||
the DDM (Digital Diagnostic Monitoring)
|
||
(Temperature = AV/256) (Unit =
|
||
C) <Help> This measure gives
|
||
the temperature of the line 2
|
||
transceiver
|
||
"
|
||
::= { pm801rrMesrLine 24 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineTxBias article
|
||
--- *****************************************************
|
||
|
||
pm801rrMesrlineTxBias OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 XFP/OTX Tx Bias Current
|
||
:This OID gives the bias value
|
||
of the Line XFP/OTX, read from
|
||
the DDM (Digital Diagnostic Monitoring)
|
||
(Bias = AV/500) (Unit = mA) <Help>
|
||
This measure gives the bias of
|
||
the line 2 transceiver
|
||
"
|
||
::= { pm801rrMesrLine 26 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineTxPower article
|
||
--- *****************************************************
|
||
|
||
pm801rrMesrlineTxPower OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Optical Module Tx Power
|
||
:This OID gives the transmit power
|
||
value of the Line XFP/OTX, read
|
||
from the DDM (Digital Diagnostic
|
||
Monitoring) (Power = 10*log(AV)-40)
|
||
(Unit = dBm) <Help> This measure
|
||
gives the Tx optical power of the
|
||
line 2 transceiver
|
||
"
|
||
::= { pm801rrMesrLine 27 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineRxPower article
|
||
--- *****************************************************
|
||
|
||
pm801rrMesrlineRxPower OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Optical Module Rx Power
|
||
:This OID gives the receive power
|
||
value of the Line XFP/OTX, read
|
||
from the DDM (Digital Diagnostic
|
||
Monitoring) (Power = 10*log(AV)-40)
|
||
(Unit = dBm) <Help> This measure
|
||
gives the Rx optical power of the
|
||
line 2 transceiver
|
||
"
|
||
::= { pm801rrMesrLine 28 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientAging article
|
||
--- *****************************************************
|
||
|
||
pm801rrMesrclientAging OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 OTX TLH Aging :This OID
|
||
gives the aging of the Line 1 OTX
|
||
TLH, read from the DDM (Digital
|
||
Diagnostic Monitoring) (Aging
|
||
= AV) (Unit = %) <Help> This
|
||
measure gives the aging of the
|
||
line 1 OTX TLH
|
||
"
|
||
::= { pm801rrMesrClient 32 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientLaserTemperature article
|
||
--- *****************************************************
|
||
|
||
pm801rrMesrclientLaserTemperature OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 OTX TLH Laser Temperature
|
||
:This OID gives the laser temperature
|
||
of the Line 1 OTX TLH, read from
|
||
the DDM (Digital Diagnostic Monitoring)
|
||
(Temperature = AV/256) (Unit
|
||
= C) <Help> This measure gives
|
||
the laser temperature of the line
|
||
1 OTX TLH
|
||
"
|
||
::= { pm801rrMesrClient 33 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientFreqDeviation article
|
||
--- *****************************************************
|
||
|
||
pm801rrMesrclientFreqDeviation OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 OTX TLH Frequency Deviation
|
||
:This OID gives the frequency deviation
|
||
of the Line 1 OTX TLH, read from
|
||
the DDM (Digital Diagnostic Monitoring)
|
||
(Deviation = (AV-32768)*100) (Unit
|
||
= MHz) <Help> This measure gives
|
||
the frequency deviation of the
|
||
line 1 OTX TLH
|
||
"
|
||
::= { pm801rrMesrClient 34 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientLaserWvlength article
|
||
--- *****************************************************
|
||
|
||
pm801rrMesrclientLaserWvlength OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Optical Module Wavelength
|
||
:This OID gives the laser wavelength
|
||
of the Line 1 OTX TLH, read from
|
||
the DDM (Digital Diagnostic Monitoring)
|
||
(Wavelength=299792458/((193,100+(AV-32768
|
||
)*12,5)*10 3)) (Unit = nm) <Help>
|
||
This measure gives the laser
|
||
wavelength of the line 1 OTX TLH
|
||
"
|
||
::= { pm801rrMesrClient 35 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineAging article
|
||
--- *****************************************************
|
||
|
||
pm801rrMesrlineAging OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 OTX TLH Aging :This OID
|
||
gives the aging of the Line 2 OTX
|
||
TLH, read from the DDM (Digital
|
||
Diagnostic Monitoring) (Aging
|
||
= AV) (Unit = %) <Help> This
|
||
measure gives the aging of the
|
||
line 2 OTX TLH
|
||
"
|
||
::= { pm801rrMesrLine 40 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineLaserTemperature article
|
||
--- *****************************************************
|
||
|
||
pm801rrMesrlineLaserTemperature OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 OTX TLH Laser Temperature
|
||
:This OID gives the laser temperature
|
||
of the Line 2 OTX TLH, read from
|
||
the DDM (Digital Diagnostic Monitoring)
|
||
(Temperature = AV/256) (Unit
|
||
= C) <Help> This measure gives
|
||
the laser temperature of the line
|
||
2 OTX TLH
|
||
"
|
||
::= { pm801rrMesrLine 41 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineFreqDeviation article
|
||
--- *****************************************************
|
||
|
||
pm801rrMesrlineFreqDeviation OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 OTX TLH Frequency Deviation
|
||
:This OID gives the frequency deviation
|
||
of the Line 2 OTX TLH, read from
|
||
the DDM (Digital Diagnostic Monitoring)
|
||
(Deviation = (AV-32768)*100) (Unit
|
||
= MHz) <Help> This measure gives
|
||
the frequency deviation of the
|
||
line 2 OTX TLH
|
||
"
|
||
::= { pm801rrMesrLine 42 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineLaserWvlength article
|
||
--- *****************************************************
|
||
|
||
pm801rrMesrlineLaserWvlength OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Optical Module Wavelength
|
||
:This OID gives the laser wavelength
|
||
of the Line 2 OTX TLH, read from
|
||
the DDM (Digital Diagnostic Monitoring)
|
||
(Wavelength=299792458/((193,100+(AV-32768
|
||
)*12,5)*10 3)) (Unit = nm) <Help>
|
||
This measure gives the laser wavelength
|
||
of the line 2 OTX TLH
|
||
"
|
||
::= { pm801rrMesrLine 43 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- CONFIG
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group lsd
|
||
--- *****************************************************
|
||
|
||
pm801rrCfgLsd OBJECT IDENTIFIER ::= { pm801rrConfig 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table 0012
|
||
--- *****************************************************
|
||
|
||
pm801rrtableclientLsd OBJECT IDENTIFIER ::= { pm801rrCfgLsd 1 }
|
||
|
||
|
||
|
||
pm801rrCfglsdMode OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
LSD mode on Client/Line Port
|
||
:This OID enables/disables the
|
||
automatic laser shutdown on the
|
||
Client and Line ports
|
||
"
|
||
::= { pm801rrtableclientLsd 2 }
|
||
|
||
|
||
|
||
pm801rrCfgclientXfpAlarms OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
LSD contributors on Client port
|
||
:This OID configures the contributors
|
||
for the automatic laser shutdown
|
||
of the client port
|
||
"
|
||
::= { pm801rrtableclientLsd 3 }
|
||
|
||
|
||
|
||
pm801rrCfgclientXfpAbsence OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
LSD contributors on Client port
|
||
:This OID configures the contributors
|
||
for the automatic laser shutdown
|
||
of the client port
|
||
"
|
||
::= { pm801rrtableclientLsd 4 }
|
||
|
||
|
||
|
||
pm801rrCfglineXfpAlarms OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
LSD contributors on Line port
|
||
:This OID configures the contributors
|
||
for the automatic laser shutdown
|
||
of the line port
|
||
"
|
||
::= { pm801rrtableclientLsd 5 }
|
||
|
||
|
||
|
||
pm801rrCfglineXfpAbsence OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
LSD contributors on Line port
|
||
:This OID configures the contributors
|
||
for the automatic laser shutdown
|
||
of the line port
|
||
"
|
||
::= { pm801rrtableclientLsd 6 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group startUp
|
||
--- *****************************************************
|
||
|
||
pm801rrCfgStartUp OBJECT IDENTIFIER ::= { pm801rrConfig 2 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table 2111
|
||
--- *****************************************************
|
||
|
||
pm801rrtableclientStartup OBJECT IDENTIFIER ::= { pm801rrCfgStartUp 1 }
|
||
|
||
|
||
|
||
pm801rrCfgclientXfpCtrl OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Line 1 Port
|
||
:This register configures the
|
||
default initialisation settings
|
||
on the client port.
|
||
"
|
||
::= { pm801rrtableclientStartup 2 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table 2191
|
||
--- *****************************************************
|
||
|
||
pm801rrtablelineStartup OBJECT IDENTIFIER ::= { pm801rrCfgStartUp 2 }
|
||
|
||
|
||
|
||
pm801rrCfglineXfpCtrl OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Line 2 Port
|
||
:This register configures the
|
||
default initialisation settings
|
||
on the line port.
|
||
"
|
||
::= { pm801rrtablelineStartup 2 }
|
||
|
||
|
||
|
||
pm801rrCfgprotocolSelect OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Bitrate selection on Line/Client
|
||
port :This OID register configure
|
||
the bitrate for the client and
|
||
line interface (0=9,953 Gb/s -
|
||
1=10,3125 Gb/s - 2=9,953 Gb/s -
|
||
3=10,518 Gb/s - 4=10,664 Gb/s -
|
||
5=10,709 Gb/s).
|
||
"
|
||
::= { pm801rrtablelineStartup 18 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table 2511
|
||
--- *****************************************************
|
||
|
||
pm801rrtableclientOtxtlh OBJECT IDENTIFIER ::= { pm801rrCfgStartUp 3 }
|
||
|
||
|
||
|
||
pm801rrCfgclientDitherControl OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Dither Line
|
||
1 :This register configures the
|
||
default initialisation settings
|
||
on the dither of the client port.
|
||
"
|
||
::= { pm801rrtableclientOtxtlh 2 }
|
||
|
||
|
||
|
||
pm801rrCfgclientDitherRate OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Line 1 OTX TLH FM amplitude
|
||
:This register configures the start-up
|
||
width of the frequency modulation
|
||
of the line 1 OTX TLH
|
||
"
|
||
::= { pm801rrtableclientOtxtlh 3 }
|
||
|
||
|
||
|
||
pm801rrCfgclientDitherFhz OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Line 1 OTX TLH FM frequency
|
||
:This register configures the start-up
|
||
frequency of the frequency modulation
|
||
of the line 1 OTX TLH
|
||
"
|
||
::= { pm801rrtableclientOtxtlh 4 }
|
||
|
||
|
||
|
||
pm801rrCfgclientPwrLaser OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Defaut Line 1 OTX TLH output Power
|
||
:This register configures the start-up
|
||
output power of the line 1 OTX
|
||
TLH (Unit = dBm)
|
||
"
|
||
::= { pm801rrtableclientOtxtlh 5 }
|
||
|
||
|
||
|
||
pm801rrCfgclientFCurrent OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Line 1 OTX TLH Channel
|
||
:This register configures the start-up
|
||
laser channel of the line 1 OTX
|
||
TLH
|
||
"
|
||
::= { pm801rrtableclientOtxtlh 6 }
|
||
|
||
|
||
|
||
pm801rrCfgclientGridCurrent OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Line 1 OTX TLH Grid :This
|
||
register configures the start-up
|
||
laser grid of the line 1 OTX TLH
|
||
"
|
||
::= { pm801rrtableclientOtxtlh 7 }
|
||
|
||
|
||
|
||
pm801rrCfgclientF0 OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Line 1 OTX TLH lowest
|
||
Freq :This register configures
|
||
the start-up lowest frequency supported
|
||
on the line 1 OTX TLH
|
||
"
|
||
::= { pm801rrtableclientOtxtlh 8 }
|
||
|
||
|
||
|
||
pm801rrCfgclientPhotodiodeMode OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Line 1 OTX TLH APD mode
|
||
:This register configures the start-up
|
||
APD mode of the line 1 OTX TLH
|
||
"
|
||
::= { pm801rrtableclientOtxtlh 10 }
|
||
|
||
|
||
|
||
pm801rrCfgclientPhotodiodeValue OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Line 1 OTX TLH APD atten.
|
||
:This register configures the start-up
|
||
APD attenuation on the line 1 OTX
|
||
TLH
|
||
"
|
||
::= { pm801rrtableclientOtxtlh 11 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table 2591
|
||
--- *****************************************************
|
||
|
||
pm801rrtablelineOtxtlh OBJECT IDENTIFIER ::= { pm801rrCfgStartUp 4 }
|
||
|
||
|
||
|
||
pm801rrCfglineDitherControl OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Dither Line
|
||
2 :This register configures the
|
||
default initialisation settings
|
||
on the dither of the client port.
|
||
"
|
||
::= { pm801rrtablelineOtxtlh 2 }
|
||
|
||
|
||
|
||
pm801rrCfglineDitherRate OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Line 2 OTX TLH FM amplitude
|
||
:This register configures the start-up
|
||
width of the frequency modulation
|
||
of the line 2 OTX TLH
|
||
"
|
||
::= { pm801rrtablelineOtxtlh 3 }
|
||
|
||
|
||
|
||
pm801rrCfglineDitherFhz OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Line 2 OTX TLH FM frequency
|
||
:This register configures the start-up
|
||
frequency of the frequency modulation
|
||
of the line 2 OTX TLH
|
||
"
|
||
::= { pm801rrtablelineOtxtlh 4 }
|
||
|
||
|
||
|
||
pm801rrCfglinePwrLaser OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Defaut Line 2 OTX TLH output Power
|
||
:This register configures the start-up
|
||
output power of the line 2 OTX
|
||
TLH (Unit = dBm)
|
||
"
|
||
::= { pm801rrtablelineOtxtlh 5 }
|
||
|
||
|
||
|
||
pm801rrCfglineFCurrent OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Line 2 OTX TLH Channel
|
||
:This register configures the start-up
|
||
laser channel of the line 2 OTX
|
||
TLH
|
||
"
|
||
::= { pm801rrtablelineOtxtlh 6 }
|
||
|
||
|
||
|
||
pm801rrCfglineGridCurrent OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Line 2 OTX TLH Grid :This
|
||
register configures the start-up
|
||
laser grid of the line 2 OTX TLH
|
||
"
|
||
::= { pm801rrtablelineOtxtlh 7 }
|
||
|
||
|
||
|
||
pm801rrCfglineF0 OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Line 2 OTX TLH lowest
|
||
Freq :This register configures
|
||
the start-up lowest frequency supported
|
||
on the line 2 OTX TLH
|
||
"
|
||
::= { pm801rrtablelineOtxtlh 8 }
|
||
|
||
|
||
|
||
pm801rrCfglinePhotodiodeMode OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Line 2 OTX TLH APD mode
|
||
:This register configures the start-up
|
||
APD mode of the line 2 OTX TLH
|
||
"
|
||
::= { pm801rrtablelineOtxtlh 10 }
|
||
|
||
|
||
|
||
pm801rrCfglinePhotodiodeValue OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Line 2 OTX TLH APD atten.
|
||
:This register configures the start-up
|
||
APD attenuation on the line 2 OTX
|
||
TLH
|
||
"
|
||
::= { pm801rrtablelineOtxtlh 11 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group labels
|
||
--- *****************************************************
|
||
|
||
pm801rrCfgLabels OBJECT IDENTIFIER ::= { pm801rrConfig 3 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table NO_VALUE
|
||
--- *****************************************************
|
||
|
||
pm801rrCfgLabelclientTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm801rrCfgLabelclientEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of Article
|
||
"
|
||
::= { pm801rrCfgLabels 1 }
|
||
|
||
|
||
pm801rrCfgLabelclientEntry OBJECT-TYPE
|
||
SYNTAX Pm801rrCfgLabelclientEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the labels
|
||
table
|
||
"
|
||
INDEX { pm801rrCfgLabelclientIndex }
|
||
::= { pm801rrCfgLabelclientTable 1 }
|
||
|
||
|
||
Pm801rrCfgLabelclientEntry ::=
|
||
SEQUENCE {
|
||
pm801rrCfgLabelclientIndex
|
||
INTEGER,
|
||
pm801rrCfgLabelclientPortn
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pm801rrCfgLabelclientIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the labelclient
|
||
table
|
||
"
|
||
::= { pm801rrCfgLabelclientEntry 1 }
|
||
|
||
|
||
pm801rrCfgLabelclientPortn OBJECT-TYPE
|
||
SYNTAX DisplayString( SIZE(1..16))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default settings on the label
|
||
of the Ports :These registers
|
||
configures the default initialisation
|
||
settings of the labels of the ports.
|
||
"
|
||
::= { pm801rrCfgLabelclientEntry 3 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table NO_VALUE
|
||
--- *****************************************************
|
||
|
||
pm801rrCfgLabellineTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm801rrCfgLabellineEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of Article
|
||
"
|
||
::= { pm801rrCfgLabels 2 }
|
||
|
||
|
||
pm801rrCfgLabellineEntry OBJECT-TYPE
|
||
SYNTAX Pm801rrCfgLabellineEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the labels
|
||
table
|
||
"
|
||
INDEX { pm801rrCfgLabellineIndex }
|
||
::= { pm801rrCfgLabellineTable 1 }
|
||
|
||
|
||
Pm801rrCfgLabellineEntry ::=
|
||
SEQUENCE {
|
||
pm801rrCfgLabellineIndex
|
||
INTEGER,
|
||
pm801rrCfgLabellinePortn
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pm801rrCfgLabellineIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the labelline
|
||
table
|
||
"
|
||
::= { pm801rrCfgLabellineEntry 1 }
|
||
|
||
|
||
pm801rrCfgLabellinePortn OBJECT-TYPE
|
||
SYNTAX DisplayString( SIZE(1..16))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default settings on the label
|
||
of the lines :These registers
|
||
configures the default initialisation
|
||
settings of the labels of the lines.
|
||
"
|
||
::= { pm801rrCfgLabellineEntry 3 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group startuptablefive
|
||
--- *****************************************************
|
||
|
||
pm801rrCfgStartuptablefive OBJECT IDENTIFIER ::= { pm801rrConfig 4 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table 0005
|
||
--- *****************************************************
|
||
|
||
pm801rrCfgOtxtlhcapabilitiesTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm801rrCfgOtxtlhcapabilitiesEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of Article
|
||
"
|
||
::= { pm801rrCfgStartuptablefive 1 }
|
||
|
||
|
||
pm801rrCfgOtxtlhcapabilitiesEntry OBJECT-TYPE
|
||
SYNTAX Pm801rrCfgOtxtlhcapabilitiesEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the startuptablefive
|
||
table
|
||
"
|
||
INDEX { pm801rrCfgOtxtlhcapabilitiesIndex }
|
||
::= { pm801rrCfgOtxtlhcapabilitiesTable 1 }
|
||
|
||
|
||
Pm801rrCfgOtxtlhcapabilitiesEntry ::=
|
||
SEQUENCE {
|
||
pm801rrCfgOtxtlhcapabilitiesIndex
|
||
INTEGER,
|
||
pm801rrCfgComponentTypePortn
|
||
Unsigned32,
|
||
pm801rrCfgMiscellaneousPortn
|
||
Unsigned32,
|
||
pm801rrCfgFirstChannelPortn
|
||
Unsigned32,
|
||
pm801rrCfgLastChannelPortn
|
||
Unsigned32,
|
||
pm801rrCfgGridPortn
|
||
Unsigned32
|
||
}
|
||
|
||
|
||
pm801rrCfgOtxtlhcapabilitiesIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the otxtlhcapabilities
|
||
table
|
||
"
|
||
::= { pm801rrCfgOtxtlhcapabilitiesEntry 1 }
|
||
|
||
|
||
pm801rrCfgComponentTypePortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Component parameters :This OID
|
||
defines the component parameters
|
||
"
|
||
::= { pm801rrCfgOtxtlhcapabilitiesEntry 3 }
|
||
|
||
|
||
pm801rrCfgMiscellaneousPortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Miscellaneous default settings
|
||
:This OID defines the miscellaneous
|
||
parameters
|
||
"
|
||
::= { pm801rrCfgOtxtlhcapabilitiesEntry 4 }
|
||
|
||
|
||
pm801rrCfgFirstChannelPortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Number of the first channel of
|
||
the component :This OID defines
|
||
the first channel number of the
|
||
PM
|
||
"
|
||
::= { pm801rrCfgOtxtlhcapabilitiesEntry 5 }
|
||
|
||
|
||
pm801rrCfgLastChannelPortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Number of the last channel of
|
||
the component :This OID defines
|
||
the last channel number of the
|
||
PM
|
||
"
|
||
::= { pm801rrCfgOtxtlhcapabilitiesEntry 6 }
|
||
|
||
|
||
pm801rrCfgGridPortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Grid value of the component :This
|
||
OID defines the grid of the PM
|
||
"
|
||
::= { pm801rrCfgOtxtlhcapabilitiesEntry 7 }
|
||
|
||
|
||
|
||
pm801rrCfgWriteConfiguration OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Write configuration to module:This OID
|
||
writes the complete configuration to the module"
|
||
::= { pm801rrConfig 257 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- TRAP OBJECTS
|
||
--- *****************************************************
|
||
|
||
pm801rrtrapBoardNumber OBJECT-TYPE
|
||
SYNTAX INTEGER(1..64)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Last module which generates a trap"
|
||
::= { pm801rrtraps 4 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- GLOBAL TRAPS
|
||
--- *****************************************************
|
||
|
||
pm801rrLineTrapNotUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pm801rrAlmLineDdmWarning, pm801rrtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM801RR Line Not Urgent ON"
|
||
--&ACTIONS { log, minor }
|
||
--&MATCH { pm801rrAlmLineDdmWarning "on", pm801rrtrapBoardNumber "$2"}
|
||
--&MESG "DDM Warning appears on Line Port of PM801RR in Slot $2 ($A)"
|
||
DESCRIPTION "Not urgent Line default is activated"
|
||
::= { pm801rrtraps 30 }
|
||
|
||
pm801rrLineTrapNotUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pm801rrAlmLineDdmWarning, pm801rrtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM801RR Line Not Urgent OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS { "PM801RR Line Not Urgent ON" }
|
||
--&MATCH { pm801rrAlmLineDdmWarning "on", pm801rrtrapBoardNumber "$2"}
|
||
--&MESG "DDM Warning disappears on Line Port of PM801RR in Slot $2 ($A)"
|
||
DESCRIPTION "Not urgent Line default disappeared"
|
||
::= { pm801rrtraps 31 }
|
||
|
||
pm801rrLineTrapUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pm801rrAlmLineDdmAlm, pm801rrtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM801RR Line Urgent ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pm801rrAlmLineDdmAlm "on", pm801rrtrapBoardNumber "$2"}
|
||
--&MESG "DDM Alarm appears on Line Port of PM801RR in Slot $2 ($A)"
|
||
DESCRIPTION "Urgent Line default is activated"
|
||
::= { pm801rrtraps 32 }
|
||
|
||
pm801rrLineTrapUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pm801rrAlmLineDdmAlm, pm801rrtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM801RR Line Urgent OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS { "PM801RR Line Urgent ON" }
|
||
--&MATCH { pm801rrAlmLineDdmAlm "on", pm801rrtrapBoardNumber "$2"}
|
||
--&MESG "DDM Alarm disappears on Line Port of PM801RR in Slot $2 ($A)"
|
||
DESCRIPTION "Urgent Line default disappeared"
|
||
::= { pm801rrtraps 33 }
|
||
|
||
pm801rrLineTrapCritGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pm801rrAlmLineFail, pm801rrAlmLineHwFail, pm801rrtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM801RR Line Fail ON"
|
||
--&ACTIONS { log, critical }
|
||
--&MATCH { pm801rrAlmLineFail "on", pm801rrAlmLineHwFail "*", pm801rrtrapBoardNumber "$3"}
|
||
--&MESG "Line Port Down on PM801RR in Slot $3 ($A)"
|
||
|
||
--&FILTNAME "PM801RR Line HW Fail ON (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pm801rrAlmLineFail "*", pm801rrAlmLineHwFail "on", pm801rrtrapBoardNumber "$3"}
|
||
--&MESG "Line Port Down on PM801RR in Slot $3 ($A)"
|
||
DESCRIPTION "Critical Line default is activated"
|
||
::= { pm801rrtraps 34 }
|
||
|
||
pm801rrLineTrapCritGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pm801rrAlmLineFail, pm801rrAlmLineHwFail, pm801rrtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM801RR Line Fail OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS { "PM801RR Line Fail ON" }
|
||
--&MATCH { pm801rrAlmLineFail "on", pm801rrAlmLineHwFail "*", pm801rrtrapBoardNumber "$3"}
|
||
--&MESG "Line Port Up on PM801RR in Slot $3 ($A)"
|
||
|
||
--&FILTNAME "PM801RR Line HW Fail OFF (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pm801rrAlmLineFail "*", pm801rrAlmLineHwFail "on", pm801rrtrapBoardNumber "$3"}
|
||
--&MESG "Line Port Up on PM801RR in Slot $3 ($A)"
|
||
DESCRIPTION "Critical Line default disappeared"
|
||
::= { pm801rrtraps 35 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- PORTS TRAPS
|
||
--- *****************************************************
|
||
|
||
pm801rrClientTrapNotUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pm801rrAlmClientDdmWarning, pm801rrtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM801RR Client Not Urgent ON"
|
||
--&ACTIONS { log, minor }
|
||
--&MATCH { pm801rrAlmClientDdmWarning "on", pm801rrtrapBoardNumber "$2"}
|
||
--&MESG "DDM Warning appears on Client Port of PM801RR in Slot $2 ($A)"
|
||
DESCRIPTION "Not urgent client default is activated"
|
||
::= { pm801rrtraps 40 }
|
||
|
||
pm801rrClientTrapNotUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pm801rrAlmClientDdmWarning, pm801rrtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM801RR Client Not Urgent OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS { "PM801RR Client Not Urgent ON" }
|
||
--&MATCH { pm801rrAlmClientDdmWarning "on", pm801rrtrapBoardNumber "$2"}
|
||
--&MESG "DDM Warning appears on Client Port of PM801RR in Slot $2 ($A)"
|
||
DESCRIPTION "Not urgent client default disappeared"
|
||
::= { pm801rrtraps 41 }
|
||
|
||
pm801rrClientTrapUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pm801rrAlmClientDdmAlm, pm801rrtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM801RR Client Urgent ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pm801rrAlmClientDdmAlm "on", pm801rrtrapBoardNumber "$2"}
|
||
--&MESG "DDM Alarm appears on Client Port of PM801RR in Slot $2 ($A)"
|
||
DESCRIPTION "Urgent client default is activated"
|
||
::= { pm801rrtraps 42 }
|
||
|
||
pm801rrClientTrapUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pm801rrAlmClientDdmAlm, pm801rrtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM801RR Client Urgent OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS { "PM801RR Client Urgent ON" }
|
||
--&MATCH { pm801rrAlmClientDdmAlm "on", pm801rrtrapBoardNumber "$2"}
|
||
--&MESG "DDM Alarm disappears on Client Port of PM801RR in Slot $2 ($A)"
|
||
DESCRIPTION "Urgent client default disappeared"
|
||
::= { pm801rrtraps 43 }
|
||
|
||
pm801rrClientTrapCritGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pm801rrAlmClientFail, pm801rrAlmClientHwFail, pm801rrtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM801RR Client Fail ON"
|
||
--&ACTIONS { log, critical }
|
||
--&MATCH { pm801rrAlmClientFail "on", pm801rrAlmClientHwFail "*", pm801rrtrapBoardNumber "$3"}
|
||
--&MESG "Client Port Down on PM801RR in Slot $3 ($A)"
|
||
|
||
--&FILTNAME "PM801RR Client HW Fail ON (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pm801rrAlmClientFail "*", pm801rrAlmClientHwFail "on", pm801rrtrapBoardNumber "$3"}
|
||
--&MESG "Client Port Down on PM801RR in Slot $3 ($A)"
|
||
DESCRIPTION "Critical client default is activated"
|
||
::= { pm801rrtraps 44 }
|
||
|
||
pm801rrClientTrapCritGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pm801rrAlmClientFail, pm801rrAlmClientHwFail, pm801rrtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM801RR Client Fail OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS { "PM801RR Client Fail ON" }
|
||
--&MATCH { pm801rrAlmClientFail "on", pm801rrAlmClientHwFail "*", pm801rrtrapBoardNumber "$3"}
|
||
--&MESG "Client Port Up on PM801RR in Slot $3 ($A)"
|
||
|
||
--&FILTNAME "PM801RR Client HW Fail OFF (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pm801rrAlmClientFail "*", pm801rrAlmClientHwFail "on", pm801rrtrapBoardNumber "$3"}
|
||
--&MESG "Client Port Up on PM801RR in Slot $3 ($A)"
|
||
DESCRIPTION "Critical client default disappeared"
|
||
::= { pm801rrtraps 45 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- HW TRAPS
|
||
--- *****************************************************
|
||
|
||
pm801rrPowerTrapUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pm801rrAlmDefFuseB, pm801rrAlmDefFuseA , pm801rrtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM801RR Fuse A Fail ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pm801rrAlmDefFuseB "*", pm801rrAlmDefFuseA "on", pm801rrtrapBoardNumber "$3"}
|
||
--&MESG "Power Input A Fail on PM801RR in Slot $3 ($A)"
|
||
|
||
--&FILTNAME "PM801RR Fuse B Fail ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pm801rrAlmDefFuseB "on", pm801rrAlmDefFuseA "*", pm801rrtrapBoardNumber "$3"}
|
||
--&MESG "Power Input B Fail on PM801RR in Slot $3 ($A)"
|
||
DESCRIPTION "Urgent power supply default is activated"
|
||
::= { pm801rrtraps 50 }
|
||
pm801rrPowerTrapUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pm801rrAlmDefFuseB, pm801rrAlmDefFuseA , pm801rrtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM801RR Fuse A&B Fail OFF"
|
||
--&ACTIONS { log, normal}
|
||
--&CLEARS { "PM801RR Fuse A Fail ON", "PM801RR Fuse B Fail ON" }
|
||
--&MATCH { pm801rrAlmDefFuseB "on", pm801rrAlmDefFuseA "on", pm801rrtrapBoardNumber "$3"}
|
||
--&MESG "Power Inputs A and B Present on PM801RR in Slot $3 ($A)"
|
||
DESCRIPTION "Urgent power supply default disappeared"
|
||
::= { pm801rrtraps 51 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
END
|