-- Box Services MIB overview:
|
|
-- Box Services MIB falls under dnOS MIB node of the private subtree.
|
|
|
|
DNOS-BOXSERVICES-PRIVATE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- Broadcom DNOS Box Services MIB
|
|
-- Copyright 2017-2020 Broadcom.
|
|
-- This SNMP Management Information Specification
|
|
-- embodies Broadcom's confidential and proprietary
|
|
-- intellectual property. Broadcom retains all title
|
|
-- and ownership in the Specification including any revisions.
|
|
|
|
-- This Specification is supplied "AS IS", Broadcom
|
|
-- makes no warranty, either expressed or implied,
|
|
-- as to the use, operation, condition, or performance of the
|
|
-- Specification.
|
|
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
|
|
Unsigned32, Integer32, Gauge32 FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION, TruthValue FROM SNMPv2-TC
|
|
DisplayString FROM RFC1213-MIB
|
|
CounterBasedGauge64 FROM HCNUM-TC
|
|
DeciInteger32, MilliInteger32, DBmHundreths FROM DNOS-TC
|
|
dnOS FROM DELL-REF-MIB;
|
|
|
|
fastPathBoxServices MODULE-IDENTITY
|
|
LAST-UPDATED "202106020000Z" -- 02 Jun 2021 12:00:00 GMT
|
|
ORGANIZATION "Dell"
|
|
CONTACT-INFO ""
|
|
|
|
DESCRIPTION
|
|
"The Broadcom Private MIB for DNOS Box Services Feature."
|
|
|
|
-- Revision history.
|
|
REVISION
|
|
"202106020000Z" -- 02 Jun 2021 12:00:00 GMT
|
|
DESCRIPTION
|
|
"boxServicesFiberPortsOpticsInfoTable(19) is added to display the Fiber port optics information."
|
|
REVISION
|
|
"202005210000Z" -- 21 May 2020 12:00:00 GMT
|
|
DESCRIPTION
|
|
"Support for Fiber port optics Diagonostics."
|
|
REVISION
|
|
"201806300000Z" -- 30 June 2018 12:00:00 GMT
|
|
DESCRIPTION
|
|
"General cleanup to make MIB more conformant with SMIv2."
|
|
REVISION
|
|
"201708040000Z" -- 04 Aug 2017 12:00:00 GMT
|
|
DESCRIPTION
|
|
"Max Access of Dying Gasp trap updated."
|
|
REVISION
|
|
"201101260000Z" -- 26 Jan 2011 12:00:00 GMT
|
|
DESCRIPTION
|
|
"Postal address updated."
|
|
REVISION
|
|
"200802220000Z" -- 22 Feb 2008 12:00:00 GMT
|
|
DESCRIPTION
|
|
"Dell branding related changes."
|
|
|
|
|
|
::= { dnOS 43 }
|
|
|
|
BoxsTemperatureStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temperature state"
|
|
SYNTAX INTEGER {
|
|
low(0),
|
|
normal(1),
|
|
warning(2),
|
|
critical(3),
|
|
shutdown(4),
|
|
notpresent(5),
|
|
notoperational(6)
|
|
}
|
|
|
|
--**************************************************************************************
|
|
-- boxServicesGroup
|
|
--
|
|
-- This group provides configuration and status of the Box Services
|
|
-- feature.
|
|
--
|
|
--**************************************************************************************
|
|
|
|
boxServicesGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 1 }
|
|
|
|
--**************************************************************************************
|
|
-- Some scalars
|
|
|
|
boxServicesNormalTempRangeMin OBJECT-TYPE
|
|
SYNTAX Integer32 (-100..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Lower boundary of normal temperature range."
|
|
::= { boxServicesGroup 1 }
|
|
|
|
boxServicesNormalTempRangeMax OBJECT-TYPE
|
|
SYNTAX Integer32 (-100..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Upper boundary of normal temperature range."
|
|
::= { boxServicesGroup 2 }
|
|
|
|
boxServicesTemperatureTrapEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Enable or disable temperature change event trap, raised when
|
|
temperature crosses boundaries of normal range"
|
|
::= { boxServicesGroup 3 }
|
|
|
|
boxServicesPSMStateTrapEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Enable or disable Power Supply Module state change trap."
|
|
::= { boxServicesGroup 4 }
|
|
|
|
boxServicesFanStateTrapEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Enable or disable Fan state change trap."
|
|
::= { boxServicesGroup 5 }
|
|
|
|
boxsPwrUsageHistoryUnitSampleInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (30..86400)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Interval at which power consumption data needs to be collected."
|
|
|
|
::= { boxServicesGroup 10 }
|
|
|
|
boxsPwrUsageHistoryUnitMaxSamples OBJECT-TYPE
|
|
SYNTAX INTEGER (1..168)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum number of samples to keep."
|
|
::= { boxServicesGroup 11 }
|
|
|
|
|
|
boxServicesThermalShutdownSensor OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of the sensor which initiated thermal shutdown."
|
|
::= { boxServicesGroup 13 }
|
|
|
|
boxServicesThermalShutdownTemperature OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temperature of the sensor which initiated thermal shutdown."
|
|
::= { boxServicesGroup 14 }
|
|
|
|
--**************************************************************************************
|
|
-- boxServicesFans
|
|
|
|
boxServicesFansTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BoxServicesFansEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fan Table"
|
|
::= { boxServicesGroup 6 }
|
|
|
|
boxServicesFansEntry OBJECT-TYPE
|
|
SYNTAX BoxServicesFansEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Box Services Fan Entry"
|
|
INDEX { boxServicesFanUnitIndex , boxServicesFansIndex }
|
|
::= { boxServicesFansTable 1 }
|
|
|
|
BoxServicesFansEntry ::= SEQUENCE {
|
|
boxServicesFanUnitIndex
|
|
Unsigned32,
|
|
boxServicesFansIndex
|
|
Integer32,
|
|
boxServicesFanItemType
|
|
INTEGER,
|
|
boxServicesFanItemState
|
|
INTEGER,
|
|
boxServicesFanSpeed
|
|
Integer32,
|
|
boxServicesFanDutyLevel
|
|
Integer32
|
|
}
|
|
|
|
boxServicesFanUnitIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..12)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unit index for an entry in the Box Services Fan Table"
|
|
::= { boxServicesFansEntry 6 }
|
|
|
|
boxServicesFansIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..15)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique index of fan table entry"
|
|
::= { boxServicesFansEntry 1 }
|
|
|
|
boxServicesFanItemType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fixed(1),
|
|
removable(2),
|
|
fixedAC(3),
|
|
removableDC(4),
|
|
fixedDC(5),
|
|
removableAC(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of fan"
|
|
::= { boxServicesFansEntry 2 }
|
|
|
|
boxServicesFanItemState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notpresent(1),
|
|
operational(2),
|
|
failed(3),
|
|
powering(4),
|
|
nopower(5),
|
|
notpowering(6),
|
|
incompatible(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of fan. nopower(5) - This state means the fan
|
|
is present but no AC is connected."
|
|
::= { boxServicesFansEntry 3 }
|
|
|
|
boxServicesFanSpeed OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The speed of fan"
|
|
::= { boxServicesFansEntry 4}
|
|
|
|
boxServicesFanDutyLevel OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The duty level of fan, in percents"
|
|
::= { boxServicesFansEntry 5}
|
|
|
|
boxsDyingGaspEventReason OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Dying Gasp Event Reason code string"
|
|
::= { boxServicesGroup 17 }
|
|
|
|
--**************************************************************************************
|
|
-- boxServicesPowSupplies
|
|
|
|
boxServicesPowSuppliesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BoxServicesPowSuppliesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Power Supply"
|
|
::= { boxServicesGroup 7 }
|
|
|
|
boxServicesPowSuppliesEntry OBJECT-TYPE
|
|
SYNTAX BoxServicesPowSuppliesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Box Services Power Supply Entry"
|
|
INDEX { boxServicesPowerSuppUnitIndex, boxServicesPowSupplyIndex }
|
|
::= { boxServicesPowSuppliesTable 1 }
|
|
|
|
BoxServicesPowSuppliesEntry ::= SEQUENCE {
|
|
boxServicesPowerSuppUnitIndex
|
|
Unsigned32,
|
|
boxServicesPowSupplyIndex
|
|
Integer32,
|
|
boxServicesPowSupplyItemType
|
|
INTEGER,
|
|
boxServicesPowSupplyItemState
|
|
INTEGER
|
|
}
|
|
|
|
boxServicesPowerSuppUnitIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..12)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unit index for an entry in the Box Services Power Supply Table"
|
|
::= { boxServicesPowSuppliesEntry 4 }
|
|
|
|
boxServicesPowSupplyIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..7)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique index of Power Supply Table entry"
|
|
::= { boxServicesPowSuppliesEntry 1 }
|
|
|
|
boxServicesPowSupplyItemType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fixed(1),
|
|
removable(2),
|
|
fixedAC(3),
|
|
removableDC(4),
|
|
fixedDC(5),
|
|
removableAC(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of Power Supply"
|
|
::= { boxServicesPowSuppliesEntry 2 }
|
|
|
|
|
|
boxServicesPowSupplyItemState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notpresent(1),
|
|
operational(2),
|
|
failed(3),
|
|
powering(4),
|
|
nopower(5),
|
|
notpowering(6),
|
|
incompatible(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of Power Supply.
|
|
nopower(5) - This state means the Power Supply is present
|
|
but no AC is connected.
|
|
incompatible(7) - This state is possible on boards capable
|
|
of pluggable Power Supplies."
|
|
::= { boxServicesPowSuppliesEntry 3 }
|
|
|
|
|
|
-- Box Services Unit Power Usage History table
|
|
boxsUnitPwrUsageHistoryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BoxsUnitPwrUsageHistoryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table providing configuration and status of Power Usage History feature"
|
|
::= { boxServicesGroup 9 }
|
|
|
|
boxsUnitPwrUsageHistoryEntry OBJECT-TYPE
|
|
SYNTAX BoxsUnitPwrUsageHistoryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Power Usage History Table for a Unit."
|
|
INDEX { boxsPwrUsageHistoryUnitIndex, boxsPwrUsageHistoryUnitSampleIndex }
|
|
::= { boxsUnitPwrUsageHistoryTable 1 }
|
|
|
|
|
|
BoxsUnitPwrUsageHistoryEntry::=
|
|
SEQUENCE {
|
|
boxsPwrUsageHistoryUnitIndex
|
|
INTEGER,
|
|
boxsPwrUsageHistoryUnitSampleIndex
|
|
INTEGER,
|
|
boxsPwrUsageHistoryUnitSampleTime
|
|
DisplayString,
|
|
boxsPwrUsageHistoryUnitPowerConsumption
|
|
Integer32,
|
|
boxsPwrUsageHistoryStackPowerConsumption
|
|
Integer32
|
|
}
|
|
|
|
boxsPwrUsageHistoryUnitIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a unique index for an entry in the boxsUnitPwrUsageHistoryTable.
|
|
A non-zero value indicates the unitIndex for the corresponding unit
|
|
entry in the Power Usage History Table."
|
|
::= { boxsUnitPwrUsageHistoryEntry 1 }
|
|
|
|
boxsPwrUsageHistoryUnitSampleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..168)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a unique index for an entry in the boxsUnitPwrUsageHistoryTable.
|
|
A non-zero value indicates the sampleIndex for the corresponding sample
|
|
entry in the Power Usage History Table."
|
|
::= { boxsUnitPwrUsageHistoryEntry 2 }
|
|
|
|
boxsPwrUsageHistoryUnitSampleTime OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time at which the Sample was collected."
|
|
::= { boxsUnitPwrUsageHistoryEntry 3}
|
|
|
|
boxsPwrUsageHistoryUnitPowerConsumption OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Power Consumption (mWatts) at the time of collecting the given sample."
|
|
|
|
::= { boxsUnitPwrUsageHistoryEntry 4 }
|
|
|
|
boxsPwrUsageHistoryStackPowerConsumption OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Power Consumption (mWatts) per Stack at the time of collecting the given sample."
|
|
::= { boxsUnitPwrUsageHistoryEntry 5 }
|
|
|
|
--**************************************************************************************
|
|
-- boxServicesTempSensors
|
|
|
|
boxServicesTempSensorsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BoxServicesTempSensorsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Temperature sensor"
|
|
::= { boxServicesGroup 8 }
|
|
|
|
boxServicesTempSensorsEntry OBJECT-TYPE
|
|
SYNTAX BoxServicesTempSensorsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Box Services Temperature Sensor Entry"
|
|
INDEX { boxServicesUnitIndex, boxServicesTempSensorIndex }
|
|
::= { boxServicesTempSensorsTable 1 }
|
|
|
|
BoxServicesTempSensorsEntry ::= SEQUENCE {
|
|
boxServicesUnitIndex
|
|
Unsigned32,
|
|
boxServicesTempSensorIndex
|
|
Unsigned32,
|
|
boxServicesTempSensorType
|
|
INTEGER,
|
|
boxServicesTempSensorState
|
|
BoxsTemperatureStatus,
|
|
boxServicesTempSensorTemperature
|
|
Integer32
|
|
}
|
|
|
|
boxServicesUnitIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..12)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unit index for an entry in the Box Services Temperature Sensor Table"
|
|
::= { boxServicesTempSensorsEntry 1 }
|
|
|
|
boxServicesTempSensorIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..15)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique index of temperature sensor table entry"
|
|
::= { boxServicesTempSensorsEntry 2 }
|
|
|
|
boxServicesTempSensorType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fixed(1),
|
|
removable(2),
|
|
fixedAC(3),
|
|
removableDC(4),
|
|
fixedDC(5),
|
|
removableAC(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of temperature sensor"
|
|
::= { boxServicesTempSensorsEntry 3 }
|
|
|
|
boxServicesTempSensorState OBJECT-TYPE
|
|
SYNTAX BoxsTemperatureStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The state of temperature sensor"
|
|
::= { boxServicesTempSensorsEntry 4 }
|
|
|
|
boxServicesTempSensorTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temperature value reported by sensor"
|
|
::= { boxServicesTempSensorsEntry 5 }
|
|
|
|
boxServicesTempUnitTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BoxServicesTempUnitEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Temperature status table"
|
|
::= { boxServicesGroup 15 }
|
|
|
|
boxServicesTempUnitEntry OBJECT-TYPE
|
|
SYNTAX BoxServicesTempUnitEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Box Services Temperature Unit Entry"
|
|
INDEX { boxServicesTempUnitIndex }
|
|
::= { boxServicesTempUnitTable 1 }
|
|
|
|
BoxServicesTempUnitEntry ::= SEQUENCE {
|
|
boxServicesTempUnitIndex
|
|
Unsigned32,
|
|
boxServicesTempUnitState
|
|
BoxsTemperatureStatus,
|
|
boxServicesTempUnitTemperature
|
|
Integer32
|
|
}
|
|
|
|
boxServicesTempUnitIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..12)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unit index for an entry in the Box Services Temperature Unit Table"
|
|
::= { boxServicesTempUnitEntry 1 }
|
|
|
|
boxServicesTempUnitState OBJECT-TYPE
|
|
SYNTAX BoxsTemperatureStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temperature state of the unit"
|
|
::= { boxServicesTempUnitEntry 2 }
|
|
|
|
boxServicesTempUnitTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest temperature currently reported by any sensor on the unit"
|
|
::= { boxServicesTempUnitEntry 3 }
|
|
|
|
|
|
boxServicesFiberPortsOpticsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BoxServicesFiberPortsOpticsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fiber ports optics data table"
|
|
::= { boxServicesGroup 18 }
|
|
|
|
boxServicesFiberPortsOpticsEntry OBJECT-TYPE
|
|
SYNTAX BoxServicesFiberPortsOpticsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Box Services Fiber ports optics Entry"
|
|
INDEX { boxServicesFiberPortIndex }
|
|
::= { boxServicesFiberPortsOpticsTable 1 }
|
|
|
|
BoxServicesFiberPortsOpticsEntry ::= SEQUENCE {
|
|
boxServicesFiberPortIndex
|
|
Unsigned32,
|
|
boxServicesFiberPortOpticsTemperature
|
|
DeciInteger32,
|
|
boxServicesFiberPortOpticsVoltage
|
|
MilliInteger32,
|
|
boxServicesFiberPortOpticsCurrent
|
|
DeciInteger32,
|
|
boxServicesFiberPortOpticsPowerOut
|
|
DBmHundreths,
|
|
boxServicesFiberPortOpticsPowerIn
|
|
DBmHundreths,
|
|
boxServicesFiberPortOpticsTxFault
|
|
TruthValue,
|
|
boxServicesFiberPortOpticsLos
|
|
TruthValue,
|
|
boxServicesFiberPortOpticsFaultStatus
|
|
DisplayString
|
|
}
|
|
|
|
boxServicesFiberPortIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port index for an entry in the Box Services Fiber ports optics table"
|
|
::= { boxServicesFiberPortsOpticsEntry 1 }
|
|
|
|
boxServicesFiberPortOpticsTemperature OBJECT-TYPE
|
|
SYNTAX DeciInteger32
|
|
UNITS "DEGREES"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temperature measured at this fiber port in degrees Celsius."
|
|
::= { boxServicesFiberPortsOpticsEntry 2 }
|
|
|
|
boxServicesFiberPortOpticsVoltage OBJECT-TYPE
|
|
SYNTAX MilliInteger32
|
|
UNITS "Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The voltage measured at this fiber port."
|
|
::= { boxServicesFiberPortsOpticsEntry 3 }
|
|
|
|
boxServicesFiberPortOpticsCurrent OBJECT-TYPE
|
|
SYNTAX DeciInteger32
|
|
UNITS "Milliamps"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current measured at this fiber port."
|
|
::= { boxServicesFiberPortsOpticsEntry 4 }
|
|
|
|
boxServicesFiberPortOpticsPowerOut OBJECT-TYPE
|
|
SYNTAX DBmHundreths
|
|
UNITS "dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output power measured at this fiber port."
|
|
::= { boxServicesFiberPortsOpticsEntry 5 }
|
|
|
|
boxServicesFiberPortOpticsPowerIn OBJECT-TYPE
|
|
SYNTAX DBmHundreths
|
|
UNITS "dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input power measured at this fiber port."
|
|
::= { boxServicesFiberPortsOpticsEntry 6 }
|
|
|
|
boxServicesFiberPortOpticsTxFault OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TX fault status of fiber port."
|
|
::= { boxServicesFiberPortsOpticsEntry 7 }
|
|
|
|
boxServicesFiberPortOpticsLos OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The LOS status of fiber port."
|
|
::= { boxServicesFiberPortsOpticsEntry 8 }
|
|
|
|
boxServicesFiberPortOpticsFaultStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The fault status of fiber port."
|
|
::= { boxServicesFiberPortsOpticsEntry 9 }
|
|
|
|
boxServicesFiberPortsOpticsInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BoxServicesFiberPortsOpticsInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fiber ports optics info data table"
|
|
::= { boxServicesGroup 19 }
|
|
|
|
boxServicesFiberPortsOpticsInfoEntry OBJECT-TYPE
|
|
SYNTAX BoxServicesFiberPortsOpticsInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Box Services Fiber ports optics info Entry"
|
|
INDEX { boxServicesFiberPortsOpticsInfoPortIndex }
|
|
::= { boxServicesFiberPortsOpticsInfoTable 1 }
|
|
|
|
BoxServicesFiberPortsOpticsInfoEntry ::= SEQUENCE {
|
|
boxServicesFiberPortsOpticsInfoPortIndex
|
|
Unsigned32,
|
|
boxServicesFiberPortsOpticsInfoVendorName
|
|
DisplayString,
|
|
boxServicesFiberPortsOpticsInfoLinkLength50um
|
|
Unsigned32,
|
|
boxServicesFiberPortsOpticsInfoLinkLength62dot5um
|
|
Unsigned32,
|
|
boxServicesFiberPortsOpticsInfoSerialNumber
|
|
DisplayString,
|
|
boxServicesFiberPortsOpticsInfoPartNumber
|
|
DisplayString,
|
|
boxServicesFiberPortsOpticsInfoNominalBitRate
|
|
Unsigned32,
|
|
boxServicesFiberPortsOpticsInfoRevision
|
|
DisplayString,
|
|
boxServicesFiberPortsOpticsInfoCompliance
|
|
DisplayString
|
|
}
|
|
|
|
boxServicesFiberPortsOpticsInfoPortIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port index for an entry in the Box Services Fiber ports optics info table"
|
|
::= { boxServicesFiberPortsOpticsInfoEntry 1 }
|
|
|
|
boxServicesFiberPortsOpticsInfoVendorName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Vendor Name of the fiber port."
|
|
::= { boxServicesFiberPortsOpticsInfoEntry 2 }
|
|
|
|
boxServicesFiberPortsOpticsInfoLinkLength50um OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Link Length(50um) of the fiber port."
|
|
::= { boxServicesFiberPortsOpticsInfoEntry 3 }
|
|
|
|
boxServicesFiberPortsOpticsInfoLinkLength62dot5um OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Link Length(62.5um) of the fiber port."
|
|
::= { boxServicesFiberPortsOpticsInfoEntry 4 }
|
|
|
|
boxServicesFiberPortsOpticsInfoSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Serial Number of the fiber port."
|
|
::= { boxServicesFiberPortsOpticsInfoEntry 5 }
|
|
|
|
boxServicesFiberPortsOpticsInfoPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Part Number of the fiber port."
|
|
::= { boxServicesFiberPortsOpticsInfoEntry 6 }
|
|
|
|
boxServicesFiberPortsOpticsInfoNominalBitRate OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Nominal Bit Rate (Mbps) of the fiber port."
|
|
::= { boxServicesFiberPortsOpticsInfoEntry 7 }
|
|
|
|
boxServicesFiberPortsOpticsInfoRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Revision of the fiber port."
|
|
::= { boxServicesFiberPortsOpticsInfoEntry 8 }
|
|
|
|
boxServicesFiberPortsOpticsInfoCompliance OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Compliance of the fiber port."
|
|
::= { boxServicesFiberPortsOpticsInfoEntry 9 }
|
|
|
|
|
|
|
|
--**************************************************************************************
|
|
-- boxServicesNotificationsGroup
|
|
--
|
|
-- This group provides notification definitions for the Box Services
|
|
-- feature.
|
|
--
|
|
--**************************************************************************************
|
|
|
|
boxServicesNotificationsGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 2 }
|
|
|
|
--**************************************************************************************
|
|
-- boxServices notification definitions
|
|
|
|
boxsItemStateChangeEvent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
insertion(1),
|
|
removal(2),
|
|
becomeoperational(3),
|
|
failure(4),
|
|
losepower(5)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This event describes states of the fan or Power Supply.
|
|
insertion - hot-pluggable fan or Power Supply was inserted
|
|
removal - hot-pluggable fan or Power Supply was removed
|
|
becomeoperational - fan or Power Supply became operational after failure state
|
|
failure - fan or Power Supply failure happened, i.e. it is not able to perform its functions
|
|
losepower - a Power Supply was operational, but the power to it has been disconnected or has failed"
|
|
::= { boxServicesNotificationsGroup 1 }
|
|
|
|
boxsTemperatureChangeEvent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
abovethreshold(1),
|
|
belowthreshold(2),
|
|
withinnormalrange(3)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This event describes change of the temperature.
|
|
To avoid flipping on boundary conditions, it is allowed to send the trap
|
|
taking into account some margin around thresholds.
|
|
|
|
abovethreshold - temperature increased and crossed upper threshold value
|
|
belowthreshold - temperature decreased and crossed lower threshold value
|
|
withinnormalrange - temperature returned to normal range (between threshold)"
|
|
::= { boxServicesNotificationsGroup 2 }
|
|
|
|
boxsTemperatureStatusCurrentEvent OBJECT-TYPE
|
|
SYNTAX BoxsTemperatureStatus
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This event describes the current status of a switch."
|
|
::= { boxServicesNotificationsGroup 3 }
|
|
|
|
boxsTemperatureStatusPreviousEvent OBJECT-TYPE
|
|
SYNTAX BoxsTemperatureStatus
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This event describes the previous status of a switch."
|
|
::= { boxServicesNotificationsGroup 4 }
|
|
|
|
--**************************************************************************************
|
|
-- Traps
|
|
--**************************************************************************************
|
|
|
|
fastPathBoxServicesTraps OBJECT IDENTIFIER ::= { fastPathBoxServices 0 }
|
|
|
|
boxsFanStateChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
boxServicesFansIndex,
|
|
boxsItemStateChangeEvent
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trap is sent when fan state change happens."
|
|
::= { fastPathBoxServicesTraps 1 }
|
|
|
|
boxsPowSupplyStateChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
boxServicesPowSupplyIndex,
|
|
boxsItemStateChangeEvent
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trap is sent when Power Supply state change happens."
|
|
::= { fastPathBoxServicesTraps 2 }
|
|
|
|
boxsTemperatureChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
boxServicesTempSensorIndex,
|
|
boxsTemperatureChangeEvent
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Trap is sent when temperature is changing and crossing any of the thresholds"
|
|
::= { fastPathBoxServicesTraps 3 }
|
|
|
|
boxsThermalShutdown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
boxServicesThermalShutdownSensor,
|
|
boxServicesThermalShutdownTemperature
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trap is sent when thermal shutdown is initiated."
|
|
::= { fastPathBoxServicesTraps 4 }
|
|
|
|
boxsTemperatureStateChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
boxServicesTempUnitIndex,
|
|
boxsTemperatureStatusCurrentEvent,
|
|
boxsTemperatureStatusPreviousEvent
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trap is sent when the system temperature crosses a threshold.
|
|
To avoid rapid flapping between states, a hysteresis may
|
|
be applied."
|
|
::= { fastPathBoxServicesTraps 5 }
|
|
|
|
boxsDyingGaspEventChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
boxsDyingGaspEventReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trap is sent when the Dying Gasp event is generated."
|
|
::= { fastPathBoxServicesTraps 6 }
|
|
|
|
--**************************************************************************************
|
|
-- Locator LED manage group
|
|
--
|
|
-- This group provides manage definitions for the Locator LED feature.
|
|
--
|
|
--**************************************************************************************
|
|
|
|
boxsLocatorLedConfigGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 4 }
|
|
|
|
boxsLocatorLedUnit OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Spesifies unit number where Locator LED should blink on.
|
|
This is write-only value. It always returns '0' on request."
|
|
::= { boxsLocatorLedConfigGroup 1 }
|
|
|
|
boxsLocatorLedTime OBJECT-TYPE
|
|
SYNTAX INTEGER (20..3600)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates time period in seconds for Locator LED blinking.
|
|
The range is from 20 to 3600 seconds with a default value
|
|
of 20 seconds. This is write-only value. It always returns
|
|
'0' on request."
|
|
::= { boxsLocatorLedConfigGroup 2 }
|
|
|
|
boxsLocatorLedEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Starts the Locator LED blinking. If boxsLocatorLedUnit has
|
|
not been set, the manager unit number will be used. If
|
|
boxsLocatorLedTime has not been set, the default value (20 seconds)
|
|
will be used. This is write-only value. It always returns '0'
|
|
on request."
|
|
::= { boxsLocatorLedConfigGroup 3 }
|
|
|
|
END
|