3302 lines
124 KiB
Plaintext
3302 lines
124 KiB
Plaintext
--
|
|
-- Dell Management Module MIB
|
|
-- Management Information Base
|
|
--
|
|
-- This MIB is intended for use with the OpenManage Enterprise-Modular management software.
|
|
--
|
|
-- Note that the Dell Management Module MIB file is published in both types of SMI (Structure
|
|
-- of Managed Information). This copy of the Dell Management Module MIB file is the SMIv2 version of the MIB file.
|
|
--
|
|
-- Copyright (c) 2020 Dell Inc.
|
|
--
|
|
-- Last Changed Revision: 1
|
|
-- Last Changed Date: 2020-01-22 13:00:00 -0500 (Wed, 22 Jan 2020)
|
|
--
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Begin MIB
|
|
------------------------------------------------------------------------------
|
|
|
|
DELL-MM-MIB-SMIv2 DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, enterprises
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION, DisplayString
|
|
FROM SNMPv2-TC
|
|
OBJECT-GROUP,NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF;
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Textual Conventions
|
|
------------------------------------------------------------------------------
|
|
|
|
DellString ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"General string type."
|
|
SYNTAX OCTET STRING (SIZE (0..1023))
|
|
|
|
--
|
|
-- Management Module Types
|
|
--
|
|
DellMmType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management Module Types."
|
|
SYNTAX INTEGER {
|
|
other(1), -- the MM type is not one of the following
|
|
unknown(2), -- the MM type is unknown
|
|
mxMM(3) -- MX Chassis (MM)
|
|
|
|
}
|
|
|
|
DellStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status Information."
|
|
SYNTAX INTEGER {
|
|
other(1), -- the status of the object is not one of the following:
|
|
unknown(2), -- the status of the object is unknown
|
|
-- (not known or monitored)
|
|
ok(3), -- the status of the object is ok
|
|
nonCritical(4), -- the status of the object is warning, non-critical
|
|
critical(5), -- the status of the object is critical (failure)
|
|
nonRecoverable(6) -- the status of the object is non-recoverable (dead)
|
|
|
|
}
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- DellPowerReading is a string representation of a floating point value,
|
|
-- having exactly 3 digits of precision, and a maximum of 31 characters.
|
|
--
|
|
-- DellChassisPowerIndexRange defines the possible chassis power instances
|
|
-- in this MIB.
|
|
--
|
|
-- DellPSUIndexRange defines the possible Power Supply Unit (PSU)
|
|
-- instances, per chassis power instance, in this MIB.
|
|
--
|
|
-- DellPSUCapable is an enumeration of PSU presence and/or monitoring
|
|
-- capabilities.
|
|
--
|
|
-- DellTemperatureReading is an integer value, expressed in degrees Celsius.
|
|
-------------------------------------------------------------------------------
|
|
DellPowerReading ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Power Reading."
|
|
SYNTAX OCTET STRING (SIZE (0..32))
|
|
|
|
DellPowerIndexRange ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Integer with a range of (1..1)."
|
|
SYNTAX INTEGER (1..1)
|
|
|
|
DellPSUIndexRange ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Integer with a range of (1..6)."
|
|
SYNTAX INTEGER (1..6)
|
|
|
|
DellPSUCapable ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Power Supply Information."
|
|
SYNTAX INTEGER {
|
|
absent(1), -- power supply is not present
|
|
none(2), -- no power monitoring abilities
|
|
basic(3) -- basic power monitoring abilities
|
|
|
|
}
|
|
|
|
DellTemperatureReading ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Temperature Reading."
|
|
SYNTAX INTEGER
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- DellTimestamp is defined in the displayable format:
|
|
--
|
|
-- yyyymmddHHMMSS.uuuuuuDooo
|
|
--
|
|
-- where yyyy is the year, mm is the month number, dd is the day of the month,
|
|
-- HHMMSS are the hours, minutes and seconds, respectively, uuuuuu is the
|
|
-- number of microseconds, D is the UTC offset direction, and ooo is the
|
|
-- offset from UTC, in minutes.
|
|
--
|
|
-- Note: D is a plus (+) sign if east of UTC, and a minus (-) if west of UTC.
|
|
--
|
|
-- For example, Wednesday, May 25, 1994, at 1:30:15 PM EDT
|
|
-- would be represented as: 19940525133015.000000-300
|
|
-------------------------------------------------------------------------------
|
|
DellTimestamp ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time Stamp."
|
|
SYNTAX OCTET STRING (SIZE (26))
|
|
|
|
-- MIB Objects and Tables --------------------------------------------------------
|
|
|
|
dell OBJECT IDENTIFIER ::= { enterprises 674 }
|
|
server3 OBJECT IDENTIFIER ::= { dell 10892 }
|
|
dmmOutOfBandGroup OBJECT IDENTIFIER ::= { server3 6 }
|
|
|
|
dmmInformationGroup OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 1 }
|
|
dmmProductInfoGroup OBJECT IDENTIFIER ::= { dmmInformationGroup 1 }
|
|
dmmFirmwareGroup OBJECT IDENTIFIER ::= { dmmInformationGroup 2 }
|
|
|
|
dmmStatusGroup OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 2 }
|
|
|
|
dmmChassisStatusGroup OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 3 }
|
|
dmmStatusNowGroup OBJECT IDENTIFIER ::= { dmmChassisStatusGroup 1 }
|
|
|
|
dmmChassisPowerGroup OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 4 }
|
|
|
|
DmmPowerTableEntry ::= SEQUENCE
|
|
{
|
|
dmmPowerChassisIndex DellPowerIndexRange,
|
|
dmmPowerIdlePower DellPowerReading,
|
|
dmmPowerKWhCumulative DellPowerReading,
|
|
dmmPowerKWhCumulativeTime DellTimestamp,
|
|
dmmPowerWattsPeakUsage DellPowerReading,
|
|
dmmPowerWattsPeakTime DellTimestamp,
|
|
dmmPowerWattsMinUsage DellPowerReading,
|
|
dmmPowerWattsMinTime DellTimestamp,
|
|
dmmPowerWattsReading DellPowerReading
|
|
}
|
|
|
|
DmmPSUTableEntry ::= SEQUENCE
|
|
{
|
|
dmmPSUChassisIndex DellPowerIndexRange,
|
|
dmmPSUIndex DellPSUIndexRange,
|
|
dmmPSULocation DellString,
|
|
dmmPSUState DellString,
|
|
dmmPSUType DellString,
|
|
dmmPSUCapacity DellPowerReading,
|
|
dmmPSUVoltage DellPowerReading,
|
|
dmmPSUCurrStatus DellStatus
|
|
}
|
|
|
|
dmmChassisAlert2Group OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 5 }
|
|
dmmChassisAlert2Variables OBJECT IDENTIFIER ::= { dmmChassisAlert2Group 1 }
|
|
|
|
dmmGenericAlertGroup OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 6 }
|
|
dmmGenericAlertVariables OBJECT IDENTIFIER ::= { dmmGenericAlertGroup 1 }
|
|
|
|
conformanceGroup OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 7 }
|
|
conformanceMIBGroups OBJECT IDENTIFIER ::= { conformanceGroup 1 }
|
|
conformanceMIBnotificationGroup OBJECT IDENTIFIER ::= { conformanceGroup 2 }
|
|
|
|
|
|
-- Variables and Traps ------------------------------------------------------------------------
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- group: product information
|
|
-------------------------------------------------------------------------------
|
|
dmmProductInfoObjGroup OBJECT-GROUP
|
|
OBJECTS { dmmProductName, dmmProductShortName, dmmProductDescription, dmmProductManufacturer, dmmProductVersion,
|
|
dmmChassisServiceTag, dmmProductURL, dmmProductChassisAssetTag, dmmProductChassisName, dmmProductType,
|
|
dmmProductChassisDataCenter, dmmProductChassisAisle, dmmProductChassisRack, dmmProductChassisRackSlot,dmmProductChassisModel, dmmProductChassisExpressServiceCode, dmmProductChassisSystemID
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing information about the chassis management module."
|
|
::= { conformanceMIBGroups 1 }
|
|
|
|
dmmProductName OBJECT-TYPE
|
|
SYNTAX DellString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the product name of a chassis management module."
|
|
::= { dmmProductInfoGroup 1 }
|
|
|
|
dmmProductShortName OBJECT-TYPE
|
|
SYNTAX DellString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the short product name of a chassis management module. "
|
|
::= { dmmProductInfoGroup 2 }
|
|
|
|
dmmProductDescription OBJECT-TYPE
|
|
SYNTAX DellString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the product description of a chassis management module. "
|
|
::= { dmmProductInfoGroup 3 }
|
|
|
|
dmmProductManufacturer OBJECT-TYPE
|
|
SYNTAX DellString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the product manufacturer of a chassis management module. "
|
|
::= { dmmProductInfoGroup 4 }
|
|
|
|
dmmProductVersion OBJECT-TYPE
|
|
SYNTAX DellString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the product version of a chassis management module. "
|
|
::= { dmmProductInfoGroup 5 }
|
|
|
|
dmmChassisServiceTag OBJECT-TYPE
|
|
SYNTAX DellString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the Service Tag of the chassis. "
|
|
::= { dmmProductInfoGroup 6 }
|
|
|
|
dmmProductURL OBJECT-TYPE
|
|
SYNTAX DellString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the out-of-band UI URL of a chassis management module. "
|
|
::= { dmmProductInfoGroup 7 }
|
|
|
|
dmmProductChassisAssetTag OBJECT-TYPE
|
|
SYNTAX DellString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the Asset Tag of the chassis. "
|
|
::= { dmmProductInfoGroup 8 }
|
|
|
|
dmmProductChassisName OBJECT-TYPE
|
|
SYNTAX DellString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the name of the chassis. "
|
|
::= { dmmProductInfoGroup 9 }
|
|
|
|
dmmProductType OBJECT-TYPE
|
|
SYNTAX DellMmType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines type of a remote management module "
|
|
::= { dmmProductInfoGroup 10 }
|
|
|
|
dmmProductChassisDataCenter OBJECT-TYPE
|
|
SYNTAX DellString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the Data Center locator of the chassis. "
|
|
::= { dmmProductInfoGroup 11 }
|
|
|
|
dmmProductChassisAisle OBJECT-TYPE
|
|
SYNTAX DellString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the Aisle locator of the chassis. "
|
|
::= { dmmProductInfoGroup 12 }
|
|
|
|
dmmProductChassisRack OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the Rack locator of the chassis. "
|
|
::= { dmmProductInfoGroup 13 }
|
|
|
|
dmmProductChassisRackSlot OBJECT-TYPE
|
|
SYNTAX DellString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the Rack Slot locator of the chassis. "
|
|
::= { dmmProductInfoGroup 14 }
|
|
|
|
dmmProductChassisModel OBJECT-TYPE
|
|
SYNTAX DellString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the Model of the chassis."
|
|
::= { dmmProductInfoGroup 15 }
|
|
|
|
dmmProductChassisExpressServiceCode OBJECT-TYPE
|
|
SYNTAX DellString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the Express Service Code of the chassis."
|
|
::= { dmmProductInfoGroup 16 }
|
|
|
|
dmmProductChassisSystemID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the System ID of the chassis."
|
|
::= { dmmProductInfoGroup 17 }
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- group: firmware
|
|
-------------------------------------------------------------------------------
|
|
dmmFirmwareObjGroup OBJECT-GROUP
|
|
OBJECTS { dmmFirmwareVersion, dmmFirmwareVersion2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing information about the chassis firmware version."
|
|
::= { conformanceMIBGroups 2 }
|
|
|
|
dmmFirmwareVersion OBJECT-TYPE
|
|
SYNTAX DellString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the firmware version of chassis management module 1."
|
|
::= { dmmFirmwareGroup 1 }
|
|
|
|
dmmFirmwareVersion2 OBJECT-TYPE
|
|
SYNTAX DellString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the firmware version of chassis management module 2."
|
|
::= { dmmFirmwareGroup 2 }
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- group: chassis status
|
|
-------------------------------------------------------------------------------
|
|
|
|
dmmStatusObjGroup OBJECT-GROUP
|
|
OBJECTS { dmmGlobalSystemStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Object is providing information about the overall chassis status."
|
|
::= { conformanceMIBGroups 3 }
|
|
|
|
dmmGlobalSystemStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the overall chassis status
|
|
being monitored by the chassis management module."
|
|
::= { dmmStatusGroup 1 }
|
|
|
|
dmmStatusNowObjGroup OBJECT-GROUP
|
|
OBJECTS { dmmIOMCurrStatus, dmmRedCurrStatus, dmmPowerCurrStatus, dmmFanCurrStatus, dmmBladeCurrStatus,
|
|
dmmTempCurrStatus, dmmMMCurrStatus, dmmChassisFrontPanelAmbientTemperature
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing information about the chassis subsystem status."
|
|
::= { conformanceMIBGroups 4 }
|
|
|
|
|
|
dmmIOMCurrStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the IOM subsystem status
|
|
being monitored by the chassis management module."
|
|
::= { dmmStatusNowGroup 1 }
|
|
|
|
dmmRedCurrStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the Redundancy status
|
|
being monitored by the chassis management module."
|
|
::= { dmmStatusNowGroup 2 }
|
|
|
|
dmmPowerCurrStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the power subsystem health status
|
|
being monitored by the chassis management module."
|
|
::= { dmmStatusNowGroup 3 }
|
|
|
|
dmmFanCurrStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the Fan subsystem health status
|
|
being monitored by the chassis management module."
|
|
::= { dmmStatusNowGroup 4 }
|
|
|
|
dmmBladeCurrStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the Blade subsystem health status
|
|
being monitored by the chassis management module."
|
|
::= { dmmStatusNowGroup 5 }
|
|
|
|
dmmTempCurrStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the Temp Sensor subsystem health status
|
|
being monitored by the chassis management module."
|
|
::= { dmmStatusNowGroup 6 }
|
|
|
|
dmmMMCurrStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the health status
|
|
being monitored by the chassis management module."
|
|
::= { dmmStatusNowGroup 7 }
|
|
|
|
dmmChassisFrontPanelAmbientTemperature OBJECT-TYPE
|
|
SYNTAX DellTemperatureReading
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the ambient temperature
|
|
reading (in degrees Celsius) for the chassis front panel module."
|
|
::= { dmmStatusNowGroup 8 }
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- group: chassis power
|
|
-------------------------------------------------------------------------------
|
|
dmmChassisPowerObjGroup OBJECT-GROUP
|
|
OBJECTS { dmmPowerTable, dmmPSUTable
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing information about the chassis Power."
|
|
::= { conformanceMIBGroups 5 }
|
|
|
|
|
|
|
|
dmmPowerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DmmPowerTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This object defines the power table."
|
|
::= { dmmChassisPowerGroup 1 }
|
|
|
|
dmmPowerTableEntry OBJECT-TYPE
|
|
SYNTAX DmmPowerTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This object defines the power table entry."
|
|
INDEX { dmmPowerChassisIndex }
|
|
::= { dmmPowerTable 1 }
|
|
|
|
dmmPSUTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DmmPSUTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This object defines the PSU table."
|
|
::= { dmmChassisPowerGroup 2 }
|
|
|
|
dmmPSUTableEntry OBJECT-TYPE
|
|
SYNTAX DmmPSUTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This object defines the PSU table entry."
|
|
INDEX { dmmPSUChassisIndex, dmmPSUIndex }
|
|
::= { dmmPSUTable 1 }
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- table: power information
|
|
-------------------------------------------------------------------------------
|
|
dmmPowerTableObjEntry OBJECT-GROUP
|
|
OBJECTS { dmmPowerChassisIndex, dmmPowerIdlePower, dmmPowerKWhCumulative, dmmPowerKWhCumulativeTime, dmmPowerWattsPeakUsage,
|
|
dmmPowerWattsPeakTime, dmmPowerWattsMinUsage, dmmPowerWattsMinTime, dmmPowerWattsReading
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing information about the chassis Power Information."
|
|
::= { conformanceMIBGroups 6 }
|
|
|
|
dmmPowerChassisIndex OBJECT-TYPE
|
|
SYNTAX DellPowerIndexRange
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the index
|
|
(one-based) of the associated chassis."
|
|
::= { dmmPowerTableEntry 1 }
|
|
|
|
|
|
dmmPowerIdlePower OBJECT-TYPE
|
|
SYNTAX DellPowerReading
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the power (in Watts) required by
|
|
the chassis infrastructure, plus the sum of the minimum power requirements
|
|
for all currently powered-on servers."
|
|
::= { dmmPowerTableEntry 2 }
|
|
|
|
dmmPowerKWhCumulative OBJECT-TYPE
|
|
SYNTAX DellPowerReading
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the cumulative chassis power
|
|
usage (in KWh) since last reset."
|
|
::= { dmmPowerTableEntry 3 }
|
|
|
|
dmmPowerKWhCumulativeTime OBJECT-TYPE
|
|
SYNTAX DellTimestamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the timestamp of the most recent
|
|
chassis power accumulator reset."
|
|
::= { dmmPowerTableEntry 4 }
|
|
|
|
dmmPowerWattsPeakUsage OBJECT-TYPE
|
|
SYNTAX DellPowerReading
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the chassis peak power
|
|
usage (in Watts) since last reset."
|
|
::= { dmmPowerTableEntry 5 }
|
|
|
|
dmmPowerWattsPeakTime OBJECT-TYPE
|
|
SYNTAX DellTimestamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the timestamp of the most recent
|
|
chassis peak power usage."
|
|
::= { dmmPowerTableEntry 6 }
|
|
|
|
dmmPowerWattsMinUsage OBJECT-TYPE
|
|
SYNTAX DellPowerReading
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the chassis mimimum power
|
|
usage (in Watts) since last reset."
|
|
::= { dmmPowerTableEntry 7 }
|
|
|
|
dmmPowerWattsMinTime OBJECT-TYPE
|
|
SYNTAX DellTimestamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the timestamp of the most recent
|
|
chassis minimum power usage."
|
|
::= { dmmPowerTableEntry 8 }
|
|
|
|
dmmPowerWattsReading OBJECT-TYPE
|
|
SYNTAX DellPowerReading
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the instantaneous chassis power
|
|
usage (in Watts)."
|
|
::= { dmmPowerTableEntry 9 }
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- table: PSU info
|
|
-------------------------------------------------------------------------------
|
|
|
|
dmmPSUTableObjEntry OBJECT-GROUP
|
|
OBJECTS { dmmPSUChassisIndex, dmmPSUIndex, dmmPSULocation, dmmPSUState, dmmPSUType,
|
|
dmmPSUCapacity, dmmPSUVoltage, dmmPSUCurrStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing information about the chassis Power Supply."
|
|
::= { conformanceMIBGroups 7 }
|
|
|
|
dmmPSUChassisIndex OBJECT-TYPE
|
|
SYNTAX DellPowerIndexRange
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the index
|
|
(one-based) of the associated chassis."
|
|
::= { dmmPSUTableEntry 1 }
|
|
|
|
dmmPSUIndex OBJECT-TYPE
|
|
SYNTAX DellPSUIndexRange
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the index
|
|
(one-based) of the associated PSU."
|
|
::= { dmmPSUTableEntry 2 }
|
|
|
|
dmmPSULocation OBJECT-TYPE
|
|
SYNTAX DellString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the location
|
|
of the PSU."
|
|
::= { dmmPSUTableEntry 3 }
|
|
|
|
dmmPSUState OBJECT-TYPE
|
|
SYNTAX DellString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the enabled state of
|
|
of the PSU."
|
|
::= { dmmPSUTableEntry 4 }
|
|
|
|
dmmPSUType OBJECT-TYPE
|
|
SYNTAX DellString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the type
|
|
of the PSU."
|
|
::= { dmmPSUTableEntry 5 }
|
|
|
|
dmmPSUCapacity OBJECT-TYPE
|
|
SYNTAX DellPowerReading
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the capacity in watts
|
|
of the PSU."
|
|
::= { dmmPSUTableEntry 6 }
|
|
|
|
dmmPSUVoltage OBJECT-TYPE
|
|
SYNTAX DellPowerReading
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the input voltage
|
|
of the PSU."
|
|
::= { dmmPSUTableEntry 7 }
|
|
|
|
dmmPSUCurrStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This attribute defines the current status
|
|
of the PSU."
|
|
::= { dmmPSUTableEntry 8 }
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- group: Chassis Alerts 2
|
|
-------------------------------------------------------------------------------
|
|
dmmChassisAlert2VariablesObj OBJECT-GROUP
|
|
OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing information about the chassis Alerts."
|
|
::= { conformanceMIBGroups 8 }
|
|
|
|
dmmCA2MessageID OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Message ID of the alert."
|
|
::= { dmmChassisAlert2Variables 1 }
|
|
|
|
dmmCA2Message OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Message describing the alert."
|
|
::= { dmmChassisAlert2Variables 2 }
|
|
|
|
dmmCA2MessageArgs OBJECT-TYPE
|
|
SYNTAX DellString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Concatenated set of strings representing any message arguments
|
|
that were used to construct the alert message. Each message
|
|
argument string is enclosed in double quotes, and there is a
|
|
comma after the ending double quote of each message argument
|
|
string, except the last one. Any double quotes found within a
|
|
message argument string were preprocessed and changed to single
|
|
quotes."
|
|
::= { dmmChassisAlert2Variables 3 }
|
|
|
|
dmmCA2AlertStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Status of the alert."
|
|
::= { dmmChassisAlert2Variables 4 }
|
|
|
|
dmmCA2FQDD OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..512))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fully qualified device descriptor of device causing the alert."
|
|
::= { dmmChassisAlert2Variables 5 }
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- group: Generic Alerts
|
|
-------------------------------------------------------------------------------
|
|
dmmGenericAlertVariablesObj OBJECT-GROUP
|
|
OBJECTS { dmmDeviceServiceTag
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing information about the chassis Alerts."
|
|
::= { conformanceMIBGroups 9 }
|
|
|
|
dmmDeviceServiceTag OBJECT-TYPE
|
|
SYNTAX DellString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service tag of the device."
|
|
|
|
::= { dmmGenericAlertVariables 1 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Amperage Probe Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: AMP/16
|
|
------------------------------------------------------------------------------
|
|
|
|
dmmChassisAlert2NotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { alert2AmperageProbeNormal, alert2AmperageProbeWarning, alert2AmperageProbeFailure, alert2BatteryNormal,
|
|
alert2BatteryWarning, alert2BatteryFailure, alert2CableFailure, alert2CMCWarning, alert2CMCFailure, alert2FanInformation,
|
|
alert2FanWarning, alert2FanFailure, alert2HardwareConfigurationInformation, alert2HardwareConfigurationWarning,
|
|
alert2HardwareConfigurationFailure, alert2IOVirtualizationInformation, alert2IOVirtualizationWarning, alert2IOVirtualizationFailure,
|
|
alert2LinkStatusInformation, alert2LinkStatusWarning, alert2LinkStatusFailure, alert2PowerSupplyNormal, alert2PowerSupplyWarning,
|
|
alert2PowerSupplyFailure, alert2PowerSupplyAbsent, alert2PowerUsageInformation, alert2PowerUsageWarning, alert2PowerUsageFailure,
|
|
alert2RedundancyInformation, alert2RedundancyDegraded, alert2RedundancyLost, alert2SecurityInformation, alert2SecurityWarning,
|
|
alert2SecurityFailure, alert2SystemEventLogInformation, alert2SystemEventLogWarning, alert2SystemEventLogFailure,alert2SoftwareConfigurationInformation, alert2SoftwareConfigurationWarning, alert2SoftwareConfigurationFailure, alert2TemperatureProbeNormal, alert2TemperatureProbeWarning, alert2TemperatureProbeFailure, alert2VoltageProbeNormal,
|
|
alert2VoltageProbeWarning, alert2VoltageProbeFailure, alert2StorageBatteryInformation, alert2StorageBatteryWarning,
|
|
alert2StorageBatteryFailure, alert2StorageControllerInformation, alert2StorageControllerWarning, alert2StorageControllerFailure,
|
|
alert2StorageEnclosureInformation, alert2StorageEnclosureWarning, alert2StorageEnclosureFailure, alert2StorageFanInformation,
|
|
alert2StorageFanWarning, alert2StorageFanFailure, alert2StoragePhysicalDiskInformation, alert2StoragePhysicalDiskWarning,
|
|
alert2StoragePhysicalDiskFailure, alert2StoragePowerSupplyInformation, alert2StoragePowerSupplyWarning, alert2StoragePowerSupplyFailure,
|
|
alert2StorageSecurityInformation, alert2StorageSecurityWarning, alert2StorageSecurityFailure, alert2StorageManagementInformation,
|
|
alert2StorageManagementWarning, alert2StorageManagementFailure, alert2StorageTemperatureProbeInformation, alert2StorageTemperatureProbeWarning, alert2StorageTemperatureProbeFailure, alert2StorageVirtualDiskInformation,
|
|
alert2StorageVirtualDiskWarning, alert2StorageVirtualDiskFailure, alert2SoftwareChangeUpdateWarning, alert2CMCAuditInformation,
|
|
alert2CMCAuditWarning, alert2CMCAuditFailure, alert2IOVirtualizationAuditWarning, alert2LicenseInformation,
|
|
alert2LicenseWarning, alert2LicenseFailure, alert2PCIDeviceAuditWarning, alert2PowerSupplyAuditWarning,
|
|
alert2PowerSupplyAuditFailure, alert2PowerUsageAuditInformation, alert2PowerUsageAuditWarning, alert2PowerUsageAuditFailure,
|
|
alert2SoftwareChangeAuditFailure, alert2IOVConfigurationInformation, alert2IOVConfigurationWarning,
|
|
alert2PCIDeviceConfigurationInformation, alert2SWCConfigurationWarning, alert2SWCConfigurationFailure, alert2CMCTestTrap }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The two notifications which an SNMPv2 entity is required to
|
|
implement."
|
|
::= { conformanceMIBnotificationGroup 1 }
|
|
|
|
alert2AmperageProbeNormal NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current sensor reading is within range."
|
|
--#TYPE "System: Amperage Normal"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2179 }
|
|
|
|
alert2AmperageProbeWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current sensor has detected a warning value."
|
|
--#TYPE "System: Amperage Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2178 }
|
|
|
|
alert2AmperageProbeFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current sensor has detected a failure value."
|
|
--#TYPE "System: Amperage Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2177 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Battery Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: BAT/22
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2BatteryNormal NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Battery state has returned to normal;
|
|
or battery presence had been detected."
|
|
--#TYPE "System: Battery Normal"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2227 }
|
|
|
|
alert2BatteryWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Battery is low."
|
|
--#TYPE "System: Battery Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2226 }
|
|
|
|
alert2BatteryFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Battery has failed or battery is absent."
|
|
--#TYPE "System: Battery Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2225 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Cable Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: CBL/43
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2CableFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cable failure."
|
|
--#TYPE "System: Cable Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2393 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: MM/62
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2CMCWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis Management Module detected a warning."
|
|
--#TYPE "System: Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2546 }
|
|
|
|
alert2CMCFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis Management Module detected an error."
|
|
--#TYPE "System: Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2545 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Fan Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: FAN/13
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2FanInformation NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fan information."
|
|
--#TYPE "System: Fan Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2155 }
|
|
|
|
alert2FanWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fan warning."
|
|
--#TYPE "System: Fan Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2154 }
|
|
|
|
alert2FanFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fan failure."
|
|
--#TYPE "System: Fan Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2153 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Hardware Configuration Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: HWC/35
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2HardwareConfigurationInformation NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hardware configuration information."
|
|
--#TYPE "System: Hardware Configuration Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2331 }
|
|
|
|
alert2HardwareConfigurationWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hardware configuration warning."
|
|
--#TYPE "System: Hardware Configuration Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2330 }
|
|
|
|
alert2HardwareConfigurationFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hardware configuration failure or critical event."
|
|
--#TYPE "System: Hardware Configuration Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2329 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: IO Virtualization Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: IOV/63
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2IOVirtualizationInformation NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IO Virtualization information."
|
|
--#TYPE "System: IO Virtualization Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2555 }
|
|
|
|
alert2IOVirtualizationWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IO Virtualization warning."
|
|
--#TYPE "System: IO Virtualization Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2554 }
|
|
|
|
alert2IOVirtualizationFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IO Virtualization failure or critical event."
|
|
--#TYPE "System: IO Virtualization Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2553 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Link Status Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: LNK/25
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2LinkStatusInformation NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Link status information."
|
|
--#TYPE "System: Link Status Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2251 }
|
|
|
|
alert2LinkStatusWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Link status warning."
|
|
--#TYPE "System: Link Status Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2250 }
|
|
|
|
alert2LinkStatusFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Link status failure or critical event."
|
|
--#TYPE "System: Link Status Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2249 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Power Supply Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: PSU/17
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2PowerSupplyNormal NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Power supply has returned to normal."
|
|
--#TYPE "System: Power Supply Normal"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2187 }
|
|
|
|
alert2PowerSupplyWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Power supply has detected a warning."
|
|
--#TYPE "System: Power Supply Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2186 }
|
|
|
|
alert2PowerSupplyFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Power supply has detected a failure."
|
|
--#TYPE "System: Power Supply Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2185 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Power Supply Absent Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: PSUA/52
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2PowerSupplyAbsent NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Power supply is absent."
|
|
--#TYPE "System: Power Supply Absent"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2465 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Power Usage Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: PWR/28
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2PowerUsageInformation NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Power usage information."
|
|
--#TYPE "System: Power Usage Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2275 }
|
|
|
|
alert2PowerUsageWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Power usage warning."
|
|
--#TYPE "System: Power Usage Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2274 }
|
|
|
|
alert2PowerUsageFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Power usage failure."
|
|
--#TYPE "System: Power Usage Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2273 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Redundancy Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: RDU/53
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2RedundancyInformation NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Redundancy information."
|
|
--#TYPE "System: Redundancy Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2475 }
|
|
|
|
alert2RedundancyDegraded NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Redundancy is degraded."
|
|
--#TYPE "System: Redundancy Degraded"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2474 }
|
|
|
|
alert2RedundancyLost NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Redundancy is lost."
|
|
--#TYPE "System: Redundancy Lost"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2473 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Security Event Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: SEC/42
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2SecurityInformation NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Security information."
|
|
--#TYPE "System: Security Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2387 }
|
|
|
|
alert2SecurityWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Security warning."
|
|
--#TYPE "System: Security Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2386 }
|
|
|
|
alert2SecurityFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Security failure or critical event."
|
|
--#TYPE "System: Security Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2385 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: System Event Log Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: SEL/41
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2SystemEventLogInformation NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System Event Log information."
|
|
--#TYPE "System: System Event Log Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2379 }
|
|
|
|
alert2SystemEventLogWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System Event Log warning."
|
|
--#TYPE "System: System Event Log Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2378 }
|
|
|
|
alert2SystemEventLogFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System Event Log failure or critical event."
|
|
--#TYPE "System: System Event Log Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2377 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Software Configuration Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: SWC/36
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2SoftwareConfigurationInformation NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Software configuration information."
|
|
--#TYPE "System: Software Configuration Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2339 }
|
|
|
|
alert2SoftwareConfigurationWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Software configuration warning."
|
|
--#TYPE "System: Software Configuration Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2338 }
|
|
|
|
alert2SoftwareConfigurationFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Software configuration failure."
|
|
--#TYPE "System: Software Configuration Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2337 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Temperature Probe Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: TMP/14
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2TemperatureProbeNormal NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Temperature sensor value is within range."
|
|
--#TYPE "System: Temperature Normal"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2163 }
|
|
|
|
alert2TemperatureProbeWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Temperature sensor has detected a warning value."
|
|
--#TYPE "System: Temperature Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2162 }
|
|
|
|
alert2TemperatureProbeFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Temperature sensor has detected a failure value."
|
|
--#TYPE "System: Temperature Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2161 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Voltage Probe Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: VLT/15
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2VoltageProbeNormal NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Voltage sensor reading is within range."
|
|
--#TYPE "System: Voltage Normal"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2171 }
|
|
|
|
alert2VoltageProbeWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Voltage sensor has detected a warning value."
|
|
--#TYPE "System: Voltage Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2170 }
|
|
|
|
alert2VoltageProbeFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Voltage sensor has detected a failure value."
|
|
--#TYPE "System: Voltage Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 2169 }
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Storage: Battery Traps
|
|
--
|
|
-- Category: Storage/2
|
|
-- Subcategory: BAT/22
|
|
-------------------------------------------------------------------------------
|
|
|
|
alert2StorageBatteryInformation NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Battery information."
|
|
--#TYPE "Storage: Battery Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4275 }
|
|
|
|
alert2StorageBatteryWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Battery warning."
|
|
--#TYPE "Storage: Battery Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4274 }
|
|
|
|
alert2StorageBatteryFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Battery failure."
|
|
--#TYPE "Storage: Battery Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE FAILED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4273 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Storage: Controller Traps
|
|
--
|
|
-- Category: Storage/2
|
|
-- Subcategory: CTL/29
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2StorageControllerInformation NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Controller information."
|
|
--#TYPE "Storage: Controller Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4331 }
|
|
|
|
alert2StorageControllerWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Controller warning."
|
|
--#TYPE "Storage: Controller Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4330 }
|
|
|
|
alert2StorageControllerFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Controller failure."
|
|
--#TYPE "Storage: Controller Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE FAILED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4329 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Storage: Enclosure Traps
|
|
--
|
|
-- Category: Storage/2
|
|
-- Subcategory: ENC/30
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2StorageEnclosureInformation NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Enclosure information."
|
|
--#TYPE "Storage: Enclosure Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4339 }
|
|
|
|
alert2StorageEnclosureWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Enclosure warning."
|
|
--#TYPE "Storage: Enclosure Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4338 }
|
|
|
|
alert2StorageEnclosureFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Enclosure failure."
|
|
--#TYPE "Storage: Enclosure Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE FAILED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4337 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Storage: Fan Traps
|
|
--
|
|
-- Category: Storage/2
|
|
-- Subcategory: FAN/13
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2StorageFanInformation NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Fan information."
|
|
--#TYPE "Storage: Fan Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4203 }
|
|
|
|
alert2StorageFanWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Fan warning."
|
|
--#TYPE "Storage: Fan Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4202 }
|
|
|
|
alert2StorageFanFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Fan failure."
|
|
--#TYPE "Storage: Fan Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE FAILED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4201 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Storage: Physical Disk Traps
|
|
--
|
|
-- Category: Storage/2
|
|
-- Subcategory: PDR/31
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2StoragePhysicalDiskInformation NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Physical disk information."
|
|
--#TYPE "Storage: Physical Disk Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4347 }
|
|
|
|
alert2StoragePhysicalDiskWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Physical disk warning."
|
|
--#TYPE "Storage: Physical Disk Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4346 }
|
|
|
|
alert2StoragePhysicalDiskFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Physical disk failure."
|
|
--#TYPE "Storage: Physical Disk Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE FAILED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4345 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Storage: Power Supply Traps
|
|
--
|
|
-- Category: Storage/2
|
|
-- Subcategory: PSU/17
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2StoragePowerSupplyInformation NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Power supply information."
|
|
--#TYPE "Storage: Power Supply Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4235 }
|
|
|
|
alert2StoragePowerSupplyWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Power supply warning."
|
|
--#TYPE "Storage: Power Supply Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4234 }
|
|
|
|
alert2StoragePowerSupplyFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Power supply failure."
|
|
--#TYPE "Storage: Power Supply Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE FAILED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4233 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Storage: Security Event Traps
|
|
--
|
|
-- Category: Storage/2
|
|
-- Subcategory: SEC/42
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2StorageSecurityInformation NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Security information."
|
|
--#TYPE "Storage: Security Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4435 }
|
|
|
|
alert2StorageSecurityWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Security warning."
|
|
--#TYPE "Storage: Security Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4434 }
|
|
|
|
alert2StorageSecurityFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Security failure or critical event."
|
|
--#TYPE "Storage: Security Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4433 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Storage: Storage Management Status Traps
|
|
--
|
|
-- Category: Storage/2
|
|
-- Subcategory: STOR/10
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2StorageManagementInformation NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Management information.
|
|
There is no global status change associated with this trap."
|
|
--#TYPE "Storage: Storage Management Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4179 }
|
|
|
|
alert2StorageManagementWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Management has detected a device independent warning
|
|
condition. There is no global status change associated with this
|
|
trap."
|
|
--#TYPE "Storage: Storage Management Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4178 }
|
|
|
|
alert2StorageManagementFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Management has detected a device independent error condition.
|
|
There is no global status change associated with this trap."
|
|
--#TYPE "Storage: Storage Management Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE FAILED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4177 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Storage: Temperature Probe Traps
|
|
--
|
|
-- Category: Storage/2
|
|
-- Subcategory: TMP/14
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2StorageTemperatureProbeInformation NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Temperature probe information."
|
|
--#TYPE "Storage: Temperature Probe Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4211 }
|
|
|
|
alert2StorageTemperatureProbeWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Temperature probe warning."
|
|
--#TYPE "Storage: Temperature Probe Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4210 }
|
|
|
|
alert2StorageTemperatureProbeFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Temperature probe failure."
|
|
--#TYPE "Storage: Temperature Probe Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE FAILED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4209 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Storage: Virtual Disk Traps
|
|
--
|
|
-- Category: Storage/2
|
|
-- Subcategory: VDR/32
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2StorageVirtualDiskInformation NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Virtual disk information."
|
|
--#TYPE "Storage: Virtual Disk Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4355 }
|
|
|
|
alert2StorageVirtualDiskWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Virtual disk warning."
|
|
--#TYPE "Storage: Virtual Disk Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4354 }
|
|
|
|
alert2StorageVirtualDiskFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage Virtual disk failure."
|
|
--#TYPE "Storage: Virtual Disk Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE FAILED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 4353 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Updates: Software Change Traps
|
|
--
|
|
-- Category: Updates/3
|
|
-- Subcategory: SWU/21
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2SoftwareChangeUpdateWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Software change update warning."
|
|
--#TYPE "Updates: Software Change Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 6314 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Audit: Traps
|
|
--
|
|
-- Category: Audit/4
|
|
-- Subcategory: /62
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2CMCAuditInformation NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis Management Module audit information."
|
|
--#TYPE "Audit: Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 8691 }
|
|
|
|
alert2CMCAuditWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis Management Module audit warning."
|
|
--#TYPE "Audit: Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 8690 }
|
|
|
|
alert2CMCAuditFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis Management Module audit failure or critical event."
|
|
--#TYPE "Audit: Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 8689 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Audit: IO Virtualization Traps
|
|
--
|
|
-- Category: Audit/4
|
|
-- Subcategory: IOV/63
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2IOVirtualizationAuditWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IO Virtualization audit warning."
|
|
--#TYPE "Audit: IO Virtualization Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 8698 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Audit: License Traps
|
|
--
|
|
-- Category: Audit/4
|
|
-- Subcategory: LIC/40
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2LicenseInformation NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"License information."
|
|
--#TYPE "Audit: License Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 8515 }
|
|
|
|
alert2LicenseWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"License warning."
|
|
--#TYPE "Audit: License Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 8514 }
|
|
|
|
alert2LicenseFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"License failure."
|
|
--#TYPE "Audit: License Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 8513 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Audit: PCI Device Traps
|
|
--
|
|
-- Category: Audit/4
|
|
-- Subcategory: PCI/46
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2PCIDeviceAuditWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PCI device audit warning."
|
|
--#TYPE "Audit: PCI Device Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 8562 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Audit: Power Supply Traps
|
|
--
|
|
-- Category: Audit/4
|
|
-- Subcategory: PSU/17
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2PowerSupplyAuditWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Power Supply audit warning."
|
|
--#TYPE "Audit: Power Supply Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 8330 }
|
|
|
|
alert2PowerSupplyAuditFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Power Supply audit failure or critical event."
|
|
--#TYPE "Audit: Power Supply Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 8329 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Audit: Power Usage Traps
|
|
--
|
|
-- Category: Audit/4
|
|
-- Subcategory: PWR/28
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2PowerUsageAuditInformation NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Power usage audit information."
|
|
--#TYPE "Audit: Power Usage Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 8419 }
|
|
|
|
alert2PowerUsageAuditWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Power usage audit warning."
|
|
--#TYPE "Audit: Power Usage Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 8418 }
|
|
|
|
alert2PowerUsageAuditFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Power usage audit failure or critical event."
|
|
--#TYPE "Audit: Power Usage Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 8417 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Audit: Software Change Traps
|
|
--
|
|
-- Category: Audit/4
|
|
-- Subcategory: SWU/21
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2SoftwareChangeAuditFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Software change audit failure or critical event."
|
|
--#TYPE "Audit: Software Change Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 8361 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Configuration: IO Virtualization Traps
|
|
--
|
|
-- Category: Configuration/5
|
|
-- Subcategory: IOV/63
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2IOVConfigurationInformation NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IO Virtualization configuration information."
|
|
--#TYPE "Configuration: IO Virtualization Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 10747 }
|
|
|
|
alert2IOVConfigurationWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IO Virtualization configuration warning."
|
|
--#TYPE "Configuration: IO Virtualization Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 10746 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Configuration: PCI Device Traps
|
|
--
|
|
-- Category: Configuration/5
|
|
-- Subcategory: PCI/46
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2PCIDeviceConfigurationInformation NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PCI device configuration information."
|
|
--#TYPE "Configuration: PCI Device Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 10611 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Configuration: Software Configuration Traps
|
|
--
|
|
-- Category: Configuration/5
|
|
-- Subcategory: SWC/36
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2SWCConfigurationWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Software configuration warning."
|
|
--#TYPE "Configuration: Software Configuration Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 10530 }
|
|
|
|
alert2SWCConfigurationFailure NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Software configuration failure."
|
|
--#TYPE "Configuration: Software Configuration Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
|
|
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 10529 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Configuration: Test Traps
|
|
--
|
|
-- Category: Configuration/5
|
|
-- Subcategory: TST/19
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2CMCTestTrap NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmCA2FQDD,
|
|
dmmProductChassisName,
|
|
dmmChassisServiceTag}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test trap generated in response to a user request."
|
|
--#TYPE "Configuration: Test Trap"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "%s"
|
|
--#ARGUMENTS {1}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmChassisAlert2Group 0 10395 }
|
|
|
|
|
|
dmmGenericAlertNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { alertGenericCritical, alertGenericWarning, alertGenericNormal,
|
|
alertGenericInformational, alertGenericTestTrapEvent }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The two notifications which an SNMPv2 entity is required to
|
|
implement."
|
|
::= { conformanceMIBnotificationGroup 2 }
|
|
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Alert 1: Internal: Internal MM Traps
|
|
--
|
|
-- Category: Internal/1
|
|
-- Subcategory: Internal/1
|
|
------------------------------------------------------------------------------
|
|
alertGenericCritical NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmDeviceServiceTag
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MM generic critical system alert."
|
|
--#TYPE "Internal: MM System Alert"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d "
|
|
--#ARGUMENTS {0, 1, 3}
|
|
--#CATEGORY "Internal Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmGenericAlertGroup 0 100 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- MM Alert 2: Internal: Internal MM Traps
|
|
--
|
|
-- Category: Internal/1
|
|
-- Subcategory: Internal/2
|
|
------------------------------------------------------------------------------
|
|
alertGenericWarning NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmDeviceServiceTag
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MM generic warning system alert."
|
|
--#TYPE "Internal: MM System Alert"
|
|
--#SEVERITY WARNING
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d "
|
|
--#ARGUMENTS {0, 1, 3}
|
|
--#CATEGORY "Internal Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmGenericAlertGroup 0 200 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- MM Alert 3: Internal: Internal MM Traps
|
|
--
|
|
-- Category: Internal/1
|
|
-- Subcategory: Internal/3
|
|
------------------------------------------------------------------------------
|
|
alertGenericNormal NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmDeviceServiceTag
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MM generic normal system alert."
|
|
--#TYPE "Internal: MM System Alert"
|
|
--#SEVERITY NORMAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d "
|
|
--#ARGUMENTS {0, 1, 3}
|
|
--#CATEGORY "Internal Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmGenericAlertGroup 0 300 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- MM Alert 4: Internal: Internal MM Traps
|
|
--
|
|
-- Category: Internal/1
|
|
-- Subcategory: Internal/4
|
|
------------------------------------------------------------------------------
|
|
alertGenericInformational NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2MessageID,
|
|
dmmCA2Message,
|
|
dmmCA2MessageArgs,
|
|
dmmCA2AlertStatus,
|
|
dmmDeviceServiceTag
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MM generic information system alert."
|
|
--#TYPE "Internal: MM System Alert"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d "
|
|
--#ARGUMENTS {0, 1, 3}
|
|
--#CATEGORY "Internal Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS current
|
|
::= { dmmGenericAlertGroup 0 400 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- MM Alert 5: Internal: Internal MM Traps
|
|
--
|
|
-- Category: Internal/1
|
|
-- Subcategory: Internal/5
|
|
------------------------------------------------------------------------------
|
|
alertGenericTestTrapEvent NOTIFICATION-TYPE
|
|
OBJECTS { dmmCA2Message
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MM Generated a test trap event in response to a user request."
|
|
--#TYPE "Internal: Dell MM Test TRAP Event"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "%s"
|
|
--#ARGUMENTS {0}
|
|
--#CATEGORY "Status Events"
|
|
::= { dmmGenericAlertGroup 0 500 }
|
|
|
|
END
|
|
|
|
------------------------------------------------------------------------------
|
|
-- End MIB
|
|
------------------------------------------------------------------------------
|
|
|