Observium_CE/mibs/ciscosb/CISCOSB-BLTH-MIB

122 lines
3.5 KiB
Plaintext

CISCOSB-BLTH-MIB DEFINITIONS ::= BEGIN
-- Date: 30 Mar 2022
IMPORTS
OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI
DisplayString FROM SNMPv2-TC
InterfaceIndex FROM IF-MIB
MacAddress FROM BRIDGE-MIB
switch001 FROM CISCOSB-MIB;
rlBlth MODULE-IDENTITY
LAST-UPDATED "202204300000Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO
"Postal: 170 West Tasman Drive
San Jose , CA 95134-1706
USA
Website: Cisco Small Business Support Community <http://www.cisco.com/go/smallbizsupport>"
DESCRIPTION
"The private MIB module definition for CISCOSB Bluetooth."
REVISION "202204300000Z"
DESCRIPTION
"Initial revision."
::= { switch001 246 }
rlBlthIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlBlthIfTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The (conceptual) table listing the Bluetooth group Entry."
::= {rlBlth 1}
rlBlthIfTableEntry OBJECT-TYPE
SYNTAX RlBlthIfTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The (conceptual) table listing the Bluetooth entry."
INDEX { rlBlthIfIndex}
::= { rlBlthIfTable 1 }
RlBlthIfTableEntry::=SEQUENCE {
rlBlthIfIndex InterfaceIndex,
rlBlthPin DisplayString,
rlBlthDeviceName DisplayString,
rlBlthDongleMAC MacAddress,
rlBlthDonglePresent INTEGER,
rlBlthBus DisplayString,
rlBlthState INTEGER,
rlBlthPartnerName DisplayString
}
rlBlthIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Key to Bluetooth if table"
::= { rlBlthIfTableEntry 1 }
rlBlthPin OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Stores the Bluetooth PIN used by Bluetooth Adapter"
::= { rlBlthIfTableEntry 2 }
rlBlthDeviceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Stores the device name used by Bluetooth Adapter"
::= { rlBlthIfTableEntry 3 }
rlBlthDongleMAC OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bluetooth Dongle MAC"
::= { rlBlthIfTableEntry 4 }
rlBlthDonglePresent OBJECT-TYPE
SYNTAX INTEGER{no(0), yes(1)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Represents if Bluetooth Dongle is connected"
::= { rlBlthIfTableEntry 5 }
rlBlthBus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Stores the Bluetooth Bus type"
::= { rlBlthIfTableEntry 6 }
rlBlthState OBJECT-TYPE
SYNTAX INTEGER{notready(0), discoverable(1), connected(2), admindown(3)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Stores the Bluetooth state"
::= { rlBlthIfTableEntry 7 }
rlBlthPartnerName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bluetooth partner name"
::= { rlBlthIfTableEntry 8 }
END