-- QOS-MIB: ME1200 Private MIB
|
|
--
|
|
--
|
|
-- ****************************************************************
|
|
|
|
ME1200-QOS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
MODULE-IDENTITY, OBJECT-TYPE
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION
|
|
FROM SNMPv2-TC
|
|
me1200SwitchMgmt
|
|
FROM CISCOME1200-MIB
|
|
Dscp FROM DIFFSERV-DSCP-TC
|
|
InetAddressIPv6 FROM INET-ADDRESS-MIB
|
|
ME1200EtherType FROM ME1200-TC
|
|
ME1200InterfaceIndex FROM ME1200-TC
|
|
ME1200Percent FROM ME1200-TC
|
|
ME1200PortList FROM ME1200-TC
|
|
ME1200RowEditorState FROM ME1200-TC
|
|
ME1200Unsigned16 FROM ME1200-TC
|
|
ME1200Unsigned8 FROM ME1200-TC
|
|
Integer32 FROM SNMPv2-SMI
|
|
IpAddress FROM SNMPv2-SMI
|
|
Unsigned32 FROM SNMPv2-SMI
|
|
MacAddress FROM SNMPv2-TC
|
|
TruthValue FROM SNMPv2-TC
|
|
;
|
|
|
|
me1200QosMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201408140000Z"
|
|
ORGANIZATION
|
|
"Cisco Systems, Inc"
|
|
CONTACT-INFO
|
|
"Cisco Systems, Inc
|
|
Customer Service
|
|
Postal: 170 W Tasman Drive
|
|
San Jose, CA 95134
|
|
USA
|
|
Tel: +1 800 553-NETS
|
|
E-mail: cs-me1200@cisco.com"
|
|
DESCRIPTION
|
|
"This is a private MIB for QoS"
|
|
REVISION "201408140000Z"
|
|
DESCRIPTION
|
|
"Updated various range specifications"
|
|
REVISION "201403110000Z"
|
|
DESCRIPTION
|
|
"Definition of type InterfaceIndex changed from Unsigned32 to Integer32
|
|
as it is used as index in some tables"
|
|
REVISION "201402180000Z"
|
|
DESCRIPTION
|
|
"Do no use Unsigned32 for indexes"
|
|
REVISION "201401290000Z"
|
|
DESCRIPTION
|
|
"Locate all objects under ciscoME1200MIB"
|
|
REVISION "201310080000Z"
|
|
DESCRIPTION
|
|
"Initial version"
|
|
::= { me1200SwitchMgmt 14 }
|
|
|
|
|
|
ME1200ASRType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Represents an Any/Specific/Range selector."
|
|
SYNTAX INTEGER { any(0), specific(1), range(2) }
|
|
|
|
ME1200BitType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Represents a bit selector."
|
|
SYNTAX INTEGER { any(0), zero(1), one(2) }
|
|
|
|
ME1200DestMacType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Represents a destination MAC type selector."
|
|
SYNTAX INTEGER { any(0), unicast(1), multicast(2), broadcast(3) }
|
|
|
|
ME1200DscpClassify ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An integer that indicates the DSCP classify mode."
|
|
SYNTAX INTEGER { none(0), zero(1), selected(2), all(3) }
|
|
|
|
ME1200DscpRemark ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An integer that indicates the DSCP remark mode."
|
|
SYNTAX INTEGER { disabled(0), rewrite(1), remap(2), remapDp(3) }
|
|
|
|
ME1200MaxSelector ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An integer that selects between 'Maximum Drop Probability' or 'Maximum
|
|
Fill Level'."
|
|
SYNTAX INTEGER { maximumDropProbability(0), maximumFillLevel(1) }
|
|
|
|
ME1200QceFrameType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An integer that indicates the QCE frame type key."
|
|
SYNTAX INTEGER { any(0), etype(1), llc(2), snap(3), ipv4(4), ipv6(5) }
|
|
|
|
ME1200QceUserType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An integer that indicates the QCE user type. If the value is zero it
|
|
indicates a static configuration. If the value is non-zero it indicates
|
|
a dynamic configuration made by another subsystem."
|
|
SYNTAX INTEGER { admin(0), voiceVlan(1) }
|
|
|
|
ME1200TagRemarkingMode ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An integer that indicates the tag remarking mode."
|
|
SYNTAX INTEGER { classified(0), default(2), mapped(3) }
|
|
|
|
ME1200VcapKeyType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Represents a VCAP key type selector."
|
|
SYNTAX INTEGER { normal(0), doubleTag(1), ipAddr(2), macIpAddr(3) }
|
|
|
|
ME1200VlanTagPriority ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VLAN priority."
|
|
SYNTAX INTEGER { any(0), value0(1), value1(2), value2(3), value3(4), value4(5), value5(6), value6(7), value7(8), range0to1(9), range2to3(10), range4to5(11), range6to7(12), range0to3(13), range4to7(14) }
|
|
|
|
ME1200VlanTagType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Represents a VLAN tag type selector."
|
|
SYNTAX INTEGER { any(0), untagged(1), tagged(2), cTagged(3), sTagged(4) }
|
|
|
|
me1200QosMIBObjects OBJECT IDENTIFIER
|
|
::= { me1200QosMIB 1 }
|
|
|
|
me1200QosConfig OBJECT IDENTIFIER
|
|
::= { me1200QosMIBObjects 2 }
|
|
|
|
me1200QosGlobals OBJECT IDENTIFIER
|
|
::= { me1200QosConfig 1 }
|
|
|
|
me1200QosStormPolicers OBJECT IDENTIFIER
|
|
::= { me1200QosGlobals 1 }
|
|
|
|
me1200QosStormPolicerUnicast OBJECT IDENTIFIER
|
|
::= { me1200QosStormPolicers 1 }
|
|
|
|
me1200QosStormPolicerUnicastEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the storm policer is enabled."
|
|
::= { me1200QosStormPolicerUnicast 1 }
|
|
|
|
me1200QosStormPolicerUnicastRate OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configure the storm policer rate in frames/second. Valid values are: 1,
|
|
2, 4, 8, 16, 32, 64, 128, 256, 512, 1000, 2000, 4000, 8000, 16000,
|
|
32000, 64000, 128000, 256000, 512000, 1024000"
|
|
::= { me1200QosStormPolicerUnicast 2 }
|
|
|
|
me1200QosStormPolicerMulticast OBJECT IDENTIFIER
|
|
::= { me1200QosStormPolicers 2 }
|
|
|
|
me1200QosStormPolicerMulticastEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the storm policer is enabled."
|
|
::= { me1200QosStormPolicerMulticast 1 }
|
|
|
|
me1200QosStormPolicerMulticastRate OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configure the storm policer rate in frames/second. Valid values are: 1,
|
|
2, 4, 8, 16, 32, 64, 128, 256, 512, 1000, 2000, 4000, 8000, 16000,
|
|
32000, 64000, 128000, 256000, 512000, 1024000"
|
|
::= { me1200QosStormPolicerMulticast 2 }
|
|
|
|
me1200QosStormPolicerBroadcast OBJECT IDENTIFIER
|
|
::= { me1200QosStormPolicers 3 }
|
|
|
|
me1200QosStormPolicerBroadcastEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the storm policer is enabled."
|
|
::= { me1200QosStormPolicerBroadcast 1 }
|
|
|
|
me1200QosStormPolicerBroadcastRate OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configure the storm policer rate in frames/second. Valid values are: 1,
|
|
2, 4, 8, 16, 32, 64, 128, 256, 512, 1000, 2000, 4000, 8000, 16000,
|
|
32000, 64000, 128000, 256000, 512000, 1024000"
|
|
::= { me1200QosStormPolicerBroadcast 2 }
|
|
|
|
me1200QosWredTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200QosWredEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the configuration of WRED for queue 0 through 5"
|
|
::= { me1200QosGlobals 2 }
|
|
|
|
me1200QosWredEntry OBJECT-TYPE
|
|
SYNTAX ME1200QosWredEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row contains the configuration for a specific queue"
|
|
INDEX { me1200QosWredQueue }
|
|
::= { me1200QosWredTable 1 }
|
|
|
|
ME1200QosWredEntry ::= SEQUENCE {
|
|
me1200QosWredQueue Integer32,
|
|
me1200QosWredEnable TruthValue,
|
|
me1200QosWredMinimumFillLevel ME1200Percent,
|
|
me1200QosWredMaximum ME1200Percent,
|
|
me1200QosWredMaxSelector ME1200MaxSelector
|
|
}
|
|
|
|
me1200QosWredQueue OBJECT-TYPE
|
|
SYNTAX Integer32 (0..7)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Queue index."
|
|
::= { me1200QosWredEntry 1 }
|
|
|
|
me1200QosWredEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, RED is enabled for this queue"
|
|
::= { me1200QosWredEntry 2 }
|
|
|
|
me1200QosWredMinimumFillLevel OBJECT-TYPE
|
|
SYNTAX ME1200Percent
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls the lower RED fill level threshold in percent of the whole
|
|
queue. If the queue filling level is below this threshold, the drop
|
|
probability is zero. Valid range is 0-100"
|
|
::= { me1200QosWredEntry 3 }
|
|
|
|
me1200QosWredMaximum OBJECT-TYPE
|
|
SYNTAX ME1200Percent
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls the upper RED drop probability or fill level threshold for
|
|
frames marked with Drop Precedence Level 1 (yellow frames). Valid range
|
|
is 1-100"
|
|
::= { me1200QosWredEntry 4 }
|
|
|
|
me1200QosWredMaxSelector OBJECT-TYPE
|
|
SYNTAX ME1200MaxSelector
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selects whether 'Maximum' controls 'Maximum Drop Probability' or
|
|
'Maximum Fill Level'."
|
|
::= { me1200QosWredEntry 5 }
|
|
|
|
me1200QosDscpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200QosDscpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table has 64 entries, one for each DSCP value"
|
|
::= { me1200QosGlobals 3 }
|
|
|
|
me1200QosDscpEntry OBJECT-TYPE
|
|
SYNTAX ME1200QosDscpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row contains the configuration for a specific DSCP"
|
|
INDEX { me1200QosDscpDscp }
|
|
::= { me1200QosDscpTable 1 }
|
|
|
|
ME1200QosDscpEntry ::= SEQUENCE {
|
|
me1200QosDscpDscp Dscp,
|
|
me1200QosDscpTrust TruthValue,
|
|
me1200QosDscpCos Unsigned32,
|
|
me1200QosDscpDpl ME1200Unsigned8,
|
|
me1200QosDscpIngressTranslation Dscp,
|
|
me1200QosDscpClassify TruthValue,
|
|
me1200QosDscpEgressTranslation Dscp,
|
|
me1200QosDscpEgressTranslationDp1 Dscp
|
|
}
|
|
|
|
me1200QosDscpDscp OBJECT-TYPE
|
|
SYNTAX Dscp
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DSCP index."
|
|
::= { me1200QosDscpEntry 1 }
|
|
|
|
me1200QosDscpTrust OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, this DSCP value is trusted. Packets arriving on interfaces
|
|
where 'TrustDscp' is enabled will be classified to the corresponding
|
|
CoS and DPL in this table."
|
|
::= { me1200QosDscpEntry 2 }
|
|
|
|
me1200QosDscpCos OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CoS value which the DSCP value maps to. Valid range is 0-7."
|
|
::= { me1200QosDscpEntry 3 }
|
|
|
|
me1200QosDscpDpl OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DPL (Drop Precedence Level) which the DSCP value maps to. Valid
|
|
range is 0-1."
|
|
::= { me1200QosDscpEntry 4 }
|
|
|
|
me1200QosDscpIngressTranslation OBJECT-TYPE
|
|
SYNTAX Dscp
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The new classified DSCP value which the original DSCP value is replaced
|
|
with if 'DscpTranslate' is enabled on the interface"
|
|
::= { me1200QosDscpEntry 5 }
|
|
|
|
me1200QosDscpClassify OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, then packets received on interfaces where 'DscpClassify' is
|
|
set to 'selected' will be classified to a new DSCP value based on the
|
|
classified CoS and DPL value configured in the qosCosDscpTable."
|
|
::= { me1200QosDscpEntry 6 }
|
|
|
|
me1200QosDscpEgressTranslation OBJECT-TYPE
|
|
SYNTAX Dscp
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The new DSCP value that will be written into the packet at egress if
|
|
'DscpRemark' on the interface is set to 'remap' or 'remap-dp'. If
|
|
'remap-dp' is set then only packets classified to Dpl 0 will use this
|
|
table."
|
|
::= { me1200QosDscpEntry 7 }
|
|
|
|
me1200QosDscpEgressTranslationDp1 OBJECT-TYPE
|
|
SYNTAX Dscp
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The new DSCP value that will be written into the packet at egress if
|
|
'DscpRemark' on the interface is set to 'remap-dp'. Only packets
|
|
classified to Dpl 1 will use this table."
|
|
::= { me1200QosDscpEntry 8 }
|
|
|
|
me1200QosCosToDscpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200QosCosToDscpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table has QOS_CLASS_CNT entries, one for each Cos value"
|
|
::= { me1200QosGlobals 4 }
|
|
|
|
me1200QosCosToDscpEntry OBJECT-TYPE
|
|
SYNTAX ME1200QosCosToDscpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row contains the configuration for a specific Cos"
|
|
INDEX { me1200QosCosToDscpCos }
|
|
::= { me1200QosCosToDscpTable 1 }
|
|
|
|
ME1200QosCosToDscpEntry ::= SEQUENCE {
|
|
me1200QosCosToDscpCos Integer32,
|
|
me1200QosCosToDscpDscp Dscp,
|
|
me1200QosCosToDscpDscpDp1 Dscp
|
|
}
|
|
|
|
me1200QosCosToDscpCos OBJECT-TYPE
|
|
SYNTAX Integer32 (0..7)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CoS index."
|
|
::= { me1200QosCosToDscpEntry 1 }
|
|
|
|
me1200QosCosToDscpDscp OBJECT-TYPE
|
|
SYNTAX Dscp
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DSCP value which the classified CoS value maps to when the
|
|
classified DPL is 0."
|
|
::= { me1200QosCosToDscpEntry 2 }
|
|
|
|
me1200QosCosToDscpDscpDp1 OBJECT-TYPE
|
|
SYNTAX Dscp
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DSCP value which the classified CoS value maps to when the
|
|
classified DPL is 1."
|
|
::= { me1200QosCosToDscpEntry 3 }
|
|
|
|
me1200QosQce OBJECT IDENTIFIER
|
|
::= { me1200QosGlobals 10 }
|
|
|
|
me1200QosQceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200QosQceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the configuration of QCEs. The index is QceId."
|
|
::= { me1200QosQce 1 }
|
|
|
|
me1200QosQceEntry OBJECT-TYPE
|
|
SYNTAX ME1200QosQceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row contains the configuration of a single QCE."
|
|
INDEX { me1200QosQceQceId }
|
|
::= { me1200QosQceTable 1 }
|
|
|
|
ME1200QosQceEntry ::= SEQUENCE {
|
|
me1200QosQceQceId Integer32,
|
|
me1200QosQceNextQceId Unsigned32,
|
|
me1200QosQcePortList ME1200PortList,
|
|
me1200QosQceDestMacType ME1200DestMacType,
|
|
me1200QosQceDestMac MacAddress,
|
|
me1200QosQceDestMacMask MacAddress,
|
|
me1200QosQceSrcMac MacAddress,
|
|
me1200QosQceSrcMacMask MacAddress,
|
|
me1200QosQceVlanTagType ME1200VlanTagType,
|
|
me1200QosQceVlanIdOp ME1200ASRType,
|
|
me1200QosQceVlanId ME1200Unsigned16,
|
|
me1200QosQceVlanIdRange ME1200Unsigned16,
|
|
me1200QosQcePcp ME1200VlanTagPriority,
|
|
me1200QosQceDei ME1200BitType,
|
|
me1200QosQceInnerVlanTagType ME1200VlanTagType,
|
|
me1200QosQceInnerVlanIdOp ME1200ASRType,
|
|
me1200QosQceInnerVlanId ME1200Unsigned16,
|
|
me1200QosQceInnerVlanIdRange ME1200Unsigned16,
|
|
me1200QosQceInnerPcp ME1200VlanTagPriority,
|
|
me1200QosQceInnerDei ME1200BitType,
|
|
me1200QosQceFrameType ME1200QceFrameType,
|
|
me1200QosQceEtype ME1200EtherType,
|
|
me1200QosQceLlcDsap ME1200Unsigned8,
|
|
me1200QosQceLlcDsapMask ME1200Unsigned8,
|
|
me1200QosQceLlcSsap ME1200Unsigned8,
|
|
me1200QosQceLlcSsapMask ME1200Unsigned8,
|
|
me1200QosQceLlcControl ME1200Unsigned8,
|
|
me1200QosQceLlcControlMask ME1200Unsigned8,
|
|
me1200QosQceSnapPid ME1200Unsigned16,
|
|
me1200QosQceSnapPidMask ME1200Unsigned16,
|
|
me1200QosQceIpv4Fragment ME1200BitType,
|
|
me1200QosQceIpv4DscpOp ME1200ASRType,
|
|
me1200QosQceIpv4Dscp ME1200Unsigned16,
|
|
me1200QosQceIpv4DscpRange ME1200Unsigned16,
|
|
me1200QosQceIpv4Protocol ME1200Unsigned8,
|
|
me1200QosQceIpv4ProtocolMask ME1200Unsigned8,
|
|
me1200QosQceIpv4SrcIp IpAddress,
|
|
me1200QosQceIpv4SrcIpMask IpAddress,
|
|
me1200QosQceIpv4DestIp IpAddress,
|
|
me1200QosQceIpv4DestIpMask IpAddress,
|
|
me1200QosQceIpv4SrcPortOp ME1200ASRType,
|
|
me1200QosQceIpv4SrcPort ME1200Unsigned16,
|
|
me1200QosQceIpv4SrcPortRange ME1200Unsigned16,
|
|
me1200QosQceIpv4DestPortOp ME1200ASRType,
|
|
me1200QosQceIpv4DestPort ME1200Unsigned16,
|
|
me1200QosQceIpv4DestPortRange ME1200Unsigned16,
|
|
me1200QosQceIpv6DscpOp ME1200ASRType,
|
|
me1200QosQceIpv6Dscp ME1200Unsigned16,
|
|
me1200QosQceIpv6DscpRange ME1200Unsigned16,
|
|
me1200QosQceIpv6Protocol ME1200Unsigned8,
|
|
me1200QosQceIpv6ProtocolMask ME1200Unsigned8,
|
|
me1200QosQceIpv6SrcIp InetAddressIPv6,
|
|
me1200QosQceIpv6SrcIpMask InetAddressIPv6,
|
|
me1200QosQceIpv6DestIp InetAddressIPv6,
|
|
me1200QosQceIpv6DestIpMask InetAddressIPv6,
|
|
me1200QosQceIpv6SrcPortOp ME1200ASRType,
|
|
me1200QosQceIpv6SrcPort ME1200Unsigned16,
|
|
me1200QosQceIpv6SrcPortRange ME1200Unsigned16,
|
|
me1200QosQceIpv6DestPortOp ME1200ASRType,
|
|
me1200QosQceIpv6DestPort ME1200Unsigned16,
|
|
me1200QosQceIpv6DestPortRange ME1200Unsigned16,
|
|
me1200QosQceActionCosEnable TruthValue,
|
|
me1200QosQceActionCos Unsigned32,
|
|
me1200QosQceActionDplEnable TruthValue,
|
|
me1200QosQceActionDpl ME1200Unsigned8,
|
|
me1200QosQceActionDscpEnable TruthValue,
|
|
me1200QosQceActionDscp ME1200Unsigned8,
|
|
me1200QosQceActionPcpDeiEnable TruthValue,
|
|
me1200QosQceActionPcp Unsigned32,
|
|
me1200QosQceActionDei ME1200Unsigned8,
|
|
me1200QosQceActionPolicyEnable TruthValue,
|
|
me1200QosQceActionPolicy Unsigned32,
|
|
me1200QosQceAction ME1200RowEditorState
|
|
}
|
|
|
|
me1200QosQceQceId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"QCE Id index."
|
|
::= { me1200QosQceEntry 1 }
|
|
|
|
me1200QosQceNextQceId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"QCE Id of the next QCE."
|
|
::= { me1200QosQceEntry 2 }
|
|
|
|
me1200QosQcePortList OBJECT-TYPE
|
|
SYNTAX ME1200PortList
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of ports that are member of this QCE."
|
|
::= { me1200QosQceEntry 4 }
|
|
|
|
me1200QosQceDestMacType OBJECT-TYPE
|
|
SYNTAX ME1200DestMacType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the destination MAC type to match."
|
|
::= { me1200QosQceEntry 5 }
|
|
|
|
me1200QosQceDestMac OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the 48 bits destination MAC address. The packets destination
|
|
address is AND-ed with the value of DestMacMask and then compared
|
|
against the value of this object. If this object value and the value of
|
|
DestMacMask is 00-00-00-00-00-00, this entry matches any destination
|
|
MAC address. This object can only be configured if DestMacType is
|
|
any(0) and DestMacMask is ff-ff-ff-ff-ff-ff."
|
|
::= { me1200QosQceEntry 6 }
|
|
|
|
me1200QosQceDestMacMask OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the 48 bits destination MAC address mask.Valid values are
|
|
00-00-00-00-00-00 or ff-ff-ff-ff-ff-ff."
|
|
::= { me1200QosQceEntry 7 }
|
|
|
|
me1200QosQceSrcMac OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the 48 bits source MAC address. The packets source address is
|
|
AND-ed with the value of SrcMacMask and then compared against the value
|
|
of this object. If this object value and the value of SrcMacMask is
|
|
00-00-00-00-00-00, this entry matches any source MAC address. This
|
|
object can only be configured if SrcMacMask is ff-ff-ff-ff-ff-ff."
|
|
::= { me1200QosQceEntry 8 }
|
|
|
|
me1200QosQceSrcMacMask OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the 48 bits source MAC address mask. Valid values are
|
|
00-00-00-00-00-00 or ff-ff-ff-ff-ff-ff."
|
|
::= { me1200QosQceEntry 9 }
|
|
|
|
me1200QosQceVlanTagType OBJECT-TYPE
|
|
SYNTAX ME1200VlanTagType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the VLAN tag type to match."
|
|
::= { me1200QosQceEntry 10 }
|
|
|
|
me1200QosQceVlanIdOp OBJECT-TYPE
|
|
SYNTAX ME1200ASRType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates how a packets's VLAN ID is to be compared."
|
|
::= { me1200QosQceEntry 11 }
|
|
|
|
me1200QosQceVlanId OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VLAN ID to be compared. If the VlanIdOp object in the same row is
|
|
range(2), this object will be the starting VLAN ID of the range. Valid
|
|
range is 1-4095. This object can only be configured if VlanIdOp is not
|
|
any(0)."
|
|
::= { me1200QosQceEntry 12 }
|
|
|
|
me1200QosQceVlanIdRange OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VLAN ID to be compared. If the VlanIdOp object in the same row is
|
|
range(2), this object will be the ending VLAN ID of the range. Valid
|
|
range is 1-4095. This object can only be configured if VlanIdOp is
|
|
range(2)."
|
|
::= { me1200QosQceEntry 13 }
|
|
|
|
me1200QosQcePcp OBJECT-TYPE
|
|
SYNTAX ME1200VlanTagPriority
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PCP value(s) to be compared."
|
|
::= { me1200QosQceEntry 14 }
|
|
|
|
me1200QosQceDei OBJECT-TYPE
|
|
SYNTAX ME1200BitType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DEI value to be compared. Valid range is 0-1."
|
|
::= { me1200QosQceEntry 15 }
|
|
|
|
me1200QosQceInnerVlanTagType OBJECT-TYPE
|
|
SYNTAX ME1200VlanTagType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the inner VLAN tag type to match."
|
|
::= { me1200QosQceEntry 16 }
|
|
|
|
me1200QosQceInnerVlanIdOp OBJECT-TYPE
|
|
SYNTAX ME1200ASRType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates how a packets's inner VLAN ID is to be compared."
|
|
::= { me1200QosQceEntry 17 }
|
|
|
|
me1200QosQceInnerVlanId OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The inner VLAN ID to be compared. If the InnerVlanIdOp object in the
|
|
same row is range(2), this object will be the starting VLAN ID of the
|
|
range. Valid range is 1-4095. This object can only be configured if
|
|
InnerVlanIdOp is not any(0)."
|
|
::= { me1200QosQceEntry 18 }
|
|
|
|
me1200QosQceInnerVlanIdRange OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The inner VLAN ID to be compared. If the InnerVlanIdOp object in the
|
|
same row is range(2), this object will be the ending VLAN ID of the
|
|
range. Valid range is 1-4095. This object can only be configured if
|
|
InnerVlanIdOp is range(2)."
|
|
::= { me1200QosQceEntry 19 }
|
|
|
|
me1200QosQceInnerPcp OBJECT-TYPE
|
|
SYNTAX ME1200VlanTagPriority
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The inner PCP value(s) to be compared."
|
|
::= { me1200QosQceEntry 20 }
|
|
|
|
me1200QosQceInnerDei OBJECT-TYPE
|
|
SYNTAX ME1200BitType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The inner DEI value to be compared. Valid range is 0-1."
|
|
::= { me1200QosQceEntry 21 }
|
|
|
|
me1200QosQceFrameType OBJECT-TYPE
|
|
SYNTAX ME1200QceFrameType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the packet's frame type. Modifying the frame type on an
|
|
existing QCE will restore the content of all frame type dependent
|
|
configuration to default."
|
|
::= { me1200QosQceEntry 100 }
|
|
|
|
me1200QosQceEtype OBJECT-TYPE
|
|
SYNTAX ME1200EtherType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the packet's 16 bit Ethernet type field. Valid values are:
|
|
0(match any), 0x600-0xFFFF but excluding 0x800(IPv4) and
|
|
0x86DD(IPv6).This object can only be configured if FrameType is
|
|
etype(1)."
|
|
::= { me1200QosQceEntry 101 }
|
|
|
|
me1200QosQceLlcDsap OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the packets's 8 bit LLC DSAP field. The packets LLC DSAP
|
|
field is AND-ed with the value of LlcDsapMask and then compared against
|
|
the value of this object. If this object value and the value of
|
|
LlcDsapMask is 0x00, this entry matches any LLC DSAP. Valid range is
|
|
0x00-0xFF. This object can only be configured if FrameType is llc(2)."
|
|
::= { me1200QosQceEntry 200 }
|
|
|
|
me1200QosQceLlcDsapMask OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the 8 bit LLC DSAP mask. Valid values are 0x00 or 0xFF. This
|
|
object can only be configured if FrameType is llc(2)."
|
|
::= { me1200QosQceEntry 201 }
|
|
|
|
me1200QosQceLlcSsap OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the packets's 8 bit LLC SSAP field. The packets LLC SSAP
|
|
field is AND-ed with the value of LlcSsapMask and then compared against
|
|
the value of this object. If this object value and the value of
|
|
LlcSsapMask is 0x00, this entry matches any LLC SSAP. Valid range is
|
|
0x00-0xFF. This object can only be configured if FrameType is llc(2)."
|
|
::= { me1200QosQceEntry 202 }
|
|
|
|
me1200QosQceLlcSsapMask OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the 8 bit LLC SSAP mask. Valid values are 0x00 or 0xFF. This
|
|
object can only be configured if FrameType is llc(2)."
|
|
::= { me1200QosQceEntry 203 }
|
|
|
|
me1200QosQceLlcControl OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the packets's 8 bit LLC Control field. The packets LLC
|
|
Control field is AND-ed with the value of LlcControlMask and then
|
|
compared against the value of this object. If this object value and the
|
|
value of LlcControlMask is 0x00, this entry matches any LLC Control.
|
|
Valid range is 0x00-0xFF. This object can only be configured if
|
|
FrameType is llc(2)."
|
|
::= { me1200QosQceEntry 204 }
|
|
|
|
me1200QosQceLlcControlMask OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the 8 bit LLC Control mask. Valid values are 0x00 or 0xFF.
|
|
This object can only be configured if FrameType is llc(2)."
|
|
::= { me1200QosQceEntry 205 }
|
|
|
|
me1200QosQceSnapPid OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the packet's 16 bit SNAP PID field. The packets SNAP PID
|
|
field is AND-ed with the value of SnapPidMask and then compared against
|
|
the value of this object. If this object value and the value of
|
|
SnapPidMask is 0x0000, this entry matches any ethertype. This object
|
|
can only be configured if FrameType is snap(3)."
|
|
::= { me1200QosQceEntry 302 }
|
|
|
|
me1200QosQceSnapPidMask OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the 16 bit SNAP PID mask. Valid values are 0x0000 or 0xFFFF.
|
|
This object can only be configured if FrameType is snap(3)."
|
|
::= { me1200QosQceEntry 303 }
|
|
|
|
me1200QosQceIpv4Fragment OBJECT-TYPE
|
|
SYNTAX ME1200BitType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates how an IPv4 fragment bit is to be compared. This object can
|
|
only be configured if FrameType is ipv4(4)."
|
|
::= { me1200QosQceEntry 400 }
|
|
|
|
me1200QosQceIpv4DscpOp OBJECT-TYPE
|
|
SYNTAX ME1200ASRType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates how an IPv4 DSCP field is to be compared. This object can
|
|
only be configured if FrameType is ipv4(4)."
|
|
::= { me1200QosQceEntry 401 }
|
|
|
|
me1200QosQceIpv4Dscp OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DSCP value to be compared. If the Ipv4DscpOp object in the same row
|
|
is range(2), this object will be the starting DSCP value of the range.
|
|
Valid range is 0-63. This object can only be configured if FrameType is
|
|
ipv4(4) and Ipv4DscpOp is not any(0)."
|
|
::= { me1200QosQceEntry 402 }
|
|
|
|
me1200QosQceIpv4DscpRange OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DSCP value to be compared. If the Ipv4DscpOp object in the same row
|
|
is range(2), this object will be the ending DSCP value of the range.
|
|
Valid range is 0-63. This object can only be configured if FrameType is
|
|
ipv4(4) and Ipv4DscpOp is range(2)."
|
|
::= { me1200QosQceEntry 403 }
|
|
|
|
me1200QosQceIpv4Protocol OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The protocol number field in the IPv4 header used to indicate a higher
|
|
layer protocol. The packets protocol number field is AND-ed with the
|
|
value of Ipv4ProtocolMask and then compared with the value of this
|
|
object. If Ipv4Protocol and Ipv4protocolMask are 0, this entry matches
|
|
any IPv4 protocol. Valid range is 0-255. This object can only be
|
|
configured if FrameType is ipv4(4)."
|
|
::= { me1200QosQceEntry 404 }
|
|
|
|
me1200QosQceIpv4ProtocolMask OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specified IPv4 protocol number mask. Valid values are 0 or 255.
|
|
This object can only be configured if FrameType is ipv4(4)."
|
|
::= { me1200QosQceEntry 405 }
|
|
|
|
me1200QosQceIpv4SrcIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specified IPv4 source address. The packets source address is AND-ed
|
|
with the value of Ipv4SrcIpMask and then compared with the value of
|
|
this object. If Ipv4SrcIP and Ipv4SrcIpMask are 0.0.0.0, this entry
|
|
matches any IPv4 source address. This object can only be configured if
|
|
FrameType is ipv4(4)."
|
|
::= { me1200QosQceEntry 406 }
|
|
|
|
me1200QosQceIpv4SrcIpMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specified IPv4 source address mask. This object can only be
|
|
configured if FrameType is ipv4(4)."
|
|
::= { me1200QosQceEntry 407 }
|
|
|
|
me1200QosQceIpv4DestIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specified IPv4 destination address. The packets destination address
|
|
is AND-ed with the value of Ipv4DestIpMask and then compared with the
|
|
value of this object. If Ipv4DestIP and Ipv4DestIpMask are 0.0.0.0,
|
|
this entry matches any IPv4 destination address. This object can only
|
|
be configured if FrameType is ipv4(4)."
|
|
::= { me1200QosQceEntry 408 }
|
|
|
|
me1200QosQceIpv4DestIpMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specified IPv4 destination address mask. This object can only be
|
|
configured if FrameType is ipv4(4)."
|
|
::= { me1200QosQceEntry 409 }
|
|
|
|
me1200QosQceIpv4SrcPortOp OBJECT-TYPE
|
|
SYNTAX ME1200ASRType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates how a packet's source TCP/UDP port number is to be compared.
|
|
This object can only be configured if FrameType is ipv4(4)."
|
|
::= { me1200QosQceEntry 410 }
|
|
|
|
me1200QosQceIpv4SrcPort OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source port number of the TCP or UDP protocol. If the Ipv4SrcPortOp
|
|
object in the same row is range(2), this object will be the starting
|
|
port number of the port range. Valid range is 0-65535. This object can
|
|
only be configured if FrameType is ipv4(4) and Ipv4SrcPortOp is not
|
|
any(0)."
|
|
::= { me1200QosQceEntry 411 }
|
|
|
|
me1200QosQceIpv4SrcPortRange OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source port number of the TCP or UDP protocol. If the Ipv4SrcPortOp
|
|
object in the same row is range(2), this object will be the ending port
|
|
number of the port range. Valid range is 0-65535. This object can only
|
|
be configured if FrameType is ipv4(4) and Ipv4SrcPortOp is range(2)."
|
|
::= { me1200QosQceEntry 412 }
|
|
|
|
me1200QosQceIpv4DestPortOp OBJECT-TYPE
|
|
SYNTAX ME1200ASRType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates how a packet's destination TCP/UDP port number is to be
|
|
compared. This object can only be configured if FrameType is ipv4(4)."
|
|
::= { me1200QosQceEntry 413 }
|
|
|
|
me1200QosQceIpv4DestPort OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The destination port number of the TCP or UDP protocol. If the
|
|
Ipv4DestPortOp object in the same row is range(2), this object will be
|
|
the starting port number of the port range. Valid range is 0-65535.
|
|
This object can only be configured if FrameType is ipv4(4) and
|
|
Ipv4DestPortOp is not any(0)."
|
|
::= { me1200QosQceEntry 414 }
|
|
|
|
me1200QosQceIpv4DestPortRange OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source port number of the TCP or UDP protocol. If the
|
|
Ipv4DestPortOp object in the same row is range(2), this object will be
|
|
the ending port number of the port range. Valid range is 0-65535. This
|
|
object can only be configured if FrameType is ipv4(4) and
|
|
Ipv4DestPortOp is range(2)."
|
|
::= { me1200QosQceEntry 415 }
|
|
|
|
me1200QosQceIpv6DscpOp OBJECT-TYPE
|
|
SYNTAX ME1200ASRType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates how an IPv6 DSCP field is to be compared. This object can
|
|
only be configured if FrameType is ipv6(5)."
|
|
::= { me1200QosQceEntry 500 }
|
|
|
|
me1200QosQceIpv6Dscp OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DSCP value to be compared. If the Ipv6DscpOp object in the same row
|
|
is range(2), this object will be the starting DSCP value of the range.
|
|
Valid range is 0-63. This object can only be configured if FrameType is
|
|
ipv6(5) and Ipv6DscpOp is not any(0)."
|
|
::= { me1200QosQceEntry 501 }
|
|
|
|
me1200QosQceIpv6DscpRange OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DSCP value to be compared. If the Ipv6DscpOp object in the same row
|
|
is range(2), this object will be the ending DSCP value of the range.
|
|
Valid range is 0-63. This object can only be configured if FrameType is
|
|
ipv6(5) and Ipv6DscpOp is range(2)."
|
|
::= { me1200QosQceEntry 502 }
|
|
|
|
me1200QosQceIpv6Protocol OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The protocol number field in the IPv6 header used to indicate a higher
|
|
layer protocol. The packets protocol number field is AND-ed with the
|
|
value of Ipv6ProtocolMask and then compared with the value of this
|
|
object. If Ipv46rotocol and Ipv6protocolMask are 0, this entry matches
|
|
any IPv6 protocol. Valid range is 0-255. This object can only be
|
|
configured if FrameType is ipv6(5)."
|
|
::= { me1200QosQceEntry 503 }
|
|
|
|
me1200QosQceIpv6ProtocolMask OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specified IPv6 protocol number mask. Valid values are 0 or 255.
|
|
This object can only be configured if FrameType is ipv6(5)."
|
|
::= { me1200QosQceEntry 504 }
|
|
|
|
me1200QosQceIpv6SrcIp OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specified IPv6 source address. The packets source address is AND-ed
|
|
with the value of Ipv6SrcIpMask and then compared with the value of
|
|
this object. If Ipv6SrcIP and Ipv6SrcIpMask are all zeros, this entry
|
|
matches any IPv6 source address. Only the least significant 32 bits of
|
|
this object are used. This object can only be configured if FrameType
|
|
is ipv6(5)."
|
|
::= { me1200QosQceEntry 506 }
|
|
|
|
me1200QosQceIpv6SrcIpMask OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specified IPv6 source address mask. Only the least significant 32
|
|
bits of this object are used. This object can only be configured if
|
|
FrameType is ipv6(5)."
|
|
::= { me1200QosQceEntry 508 }
|
|
|
|
me1200QosQceIpv6DestIp OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specified IPv6 destination address. The packets destination address
|
|
is AND-ed with the value of Ipv6DestIpMask and then compared with the
|
|
value of this object. If Ipv6DestIP and Ipv6DestIpMask are all zeros,
|
|
this entry matches any IPv6 destination address. Only the least
|
|
significant 32 bits of this object are used. This object can only be
|
|
configured if FrameType is ipv6(5)."
|
|
::= { me1200QosQceEntry 510 }
|
|
|
|
me1200QosQceIpv6DestIpMask OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specified IPv6 destination address mask. Only the least significant
|
|
32 bits of this object are used. This object can only be configured if
|
|
FrameType is ipv6(5)."
|
|
::= { me1200QosQceEntry 512 }
|
|
|
|
me1200QosQceIpv6SrcPortOp OBJECT-TYPE
|
|
SYNTAX ME1200ASRType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates how a packet's source TCP/UDP port number is to be compared.
|
|
This object can only be configured if FrameType is ipv6(5)."
|
|
::= { me1200QosQceEntry 513 }
|
|
|
|
me1200QosQceIpv6SrcPort OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source port number of the TCP or UDP protocol. If the Ipv6SrcPortOp
|
|
object in the same row is range(2), this object will be the starting
|
|
port number of the port range. Valid range is 0-65535. This object can
|
|
only be configured if FrameType is ipv6(5) and Ipv6SrcPortOp is not
|
|
any(0)."
|
|
::= { me1200QosQceEntry 514 }
|
|
|
|
me1200QosQceIpv6SrcPortRange OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source port number of the TCP or UDP protocol. If the Ipv6SrcPortOp
|
|
object in the same row is range(2), this object will be the ending port
|
|
number of the port range. Valid range is 0-65535. This object can only
|
|
be configured if FrameType is ipv6(5) and Ipv6SrcPortOp is range(2)."
|
|
::= { me1200QosQceEntry 515 }
|
|
|
|
me1200QosQceIpv6DestPortOp OBJECT-TYPE
|
|
SYNTAX ME1200ASRType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates how a packet's destination TCP/UDP port number is to be
|
|
compared. This object can only be configured if FrameType is ipv6(5)."
|
|
::= { me1200QosQceEntry 516 }
|
|
|
|
me1200QosQceIpv6DestPort OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The destination port number of the TCP or UDP protocol. If the
|
|
Ipv6DestPortOp object in the same row is range(2), this object will be
|
|
the starting port number of the port range. Valid range is 0-65535.
|
|
This object can only be configured if FrameType is ipv6(5) and
|
|
Ipv6DestPortOp is not any(0)."
|
|
::= { me1200QosQceEntry 517 }
|
|
|
|
me1200QosQceIpv6DestPortRange OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source port number of the TCP or UDP protocol. If the
|
|
Ipv6DestPortOp object in the same row is range(2), this object will be
|
|
the ending port number of the port range. Valid range is 0-65535. This
|
|
object can only be configured if FrameType is ipv6(5) and
|
|
Ipv6DestPortOp is range(2)."
|
|
::= { me1200QosQceEntry 518 }
|
|
|
|
me1200QosQceActionCosEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the packet is classified to the CoS value in ActionCos."
|
|
::= { me1200QosQceEntry 1000 }
|
|
|
|
me1200QosQceActionCos OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CoS value used for classification. Valid range is 0-7."
|
|
::= { me1200QosQceEntry 1001 }
|
|
|
|
me1200QosQceActionDplEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the packet is classified to the DPL value in ActionDpl."
|
|
::= { me1200QosQceEntry 1002 }
|
|
|
|
me1200QosQceActionDpl OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DPL value used for classification. Valid range is 0-1."
|
|
::= { me1200QosQceEntry 1003 }
|
|
|
|
me1200QosQceActionDscpEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the packet is classified to the DSCP value in ActionDscp."
|
|
::= { me1200QosQceEntry 1004 }
|
|
|
|
me1200QosQceActionDscp OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DSCP value used for classification. Valid range is 0-1."
|
|
::= { me1200QosQceEntry 1005 }
|
|
|
|
me1200QosQceActionPcpDeiEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the packet is classified to the PCP value in ActionPcp and the
|
|
DEI value in ActionDei."
|
|
::= { me1200QosQceEntry 1006 }
|
|
|
|
me1200QosQceActionPcp OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PCP value used for classification. Valid range is 0-7."
|
|
::= { me1200QosQceEntry 1007 }
|
|
|
|
me1200QosQceActionDei OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DEI value used for classification. Valid range is 0-1."
|
|
::= { me1200QosQceEntry 1008 }
|
|
|
|
me1200QosQceActionPolicyEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the packet is classified to the policy number in ActionPolicy."
|
|
::= { me1200QosQceEntry 1009 }
|
|
|
|
me1200QosQceActionPolicy OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The policy number used for classification. Valid range is 0-63."
|
|
::= { me1200QosQceEntry 1010 }
|
|
|
|
me1200QosQceAction OBJECT-TYPE
|
|
SYNTAX ME1200RowEditorState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Action"
|
|
::= { me1200QosQceEntry 10000 }
|
|
|
|
me1200QosQceTableRowEditor OBJECT IDENTIFIER
|
|
::= { me1200QosQce 2 }
|
|
|
|
me1200QosQceTableRowEditorQceId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"QCE Id index."
|
|
::= { me1200QosQceTableRowEditor 1 }
|
|
|
|
me1200QosQceTableRowEditorNextQceId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"QCE Id of the next QCE."
|
|
::= { me1200QosQceTableRowEditor 2 }
|
|
|
|
me1200QosQceTableRowEditorPortList OBJECT-TYPE
|
|
SYNTAX ME1200PortList
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of ports that are member of this QCE."
|
|
::= { me1200QosQceTableRowEditor 4 }
|
|
|
|
me1200QosQceTableRowEditorDestMacType OBJECT-TYPE
|
|
SYNTAX ME1200DestMacType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the destination MAC type to match."
|
|
::= { me1200QosQceTableRowEditor 5 }
|
|
|
|
me1200QosQceTableRowEditorDestMac OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the 48 bits destination MAC address. The packets destination
|
|
address is AND-ed with the value of DestMacMask and then compared
|
|
against the value of this object. If this object value and the value of
|
|
DestMacMask is 00-00-00-00-00-00, this entry matches any destination
|
|
MAC address. This object can only be configured if DestMacType is
|
|
any(0) and DestMacMask is ff-ff-ff-ff-ff-ff."
|
|
::= { me1200QosQceTableRowEditor 6 }
|
|
|
|
me1200QosQceTableRowEditorDestMacMask OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the 48 bits destination MAC address mask.Valid values are
|
|
00-00-00-00-00-00 or ff-ff-ff-ff-ff-ff."
|
|
::= { me1200QosQceTableRowEditor 7 }
|
|
|
|
me1200QosQceTableRowEditorSrcMac OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the 48 bits source MAC address. The packets source address is
|
|
AND-ed with the value of SrcMacMask and then compared against the value
|
|
of this object. If this object value and the value of SrcMacMask is
|
|
00-00-00-00-00-00, this entry matches any source MAC address. This
|
|
object can only be configured if SrcMacMask is ff-ff-ff-ff-ff-ff."
|
|
::= { me1200QosQceTableRowEditor 8 }
|
|
|
|
me1200QosQceTableRowEditorSrcMacMask OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the 48 bits source MAC address mask. Valid values are
|
|
00-00-00-00-00-00 or ff-ff-ff-ff-ff-ff."
|
|
::= { me1200QosQceTableRowEditor 9 }
|
|
|
|
me1200QosQceTableRowEditorVlanTagType OBJECT-TYPE
|
|
SYNTAX ME1200VlanTagType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the VLAN tag type to match."
|
|
::= { me1200QosQceTableRowEditor 10 }
|
|
|
|
me1200QosQceTableRowEditorVlanIdOp OBJECT-TYPE
|
|
SYNTAX ME1200ASRType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates how a packets's VLAN ID is to be compared."
|
|
::= { me1200QosQceTableRowEditor 11 }
|
|
|
|
me1200QosQceTableRowEditorVlanId OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VLAN ID to be compared. If the VlanIdOp object in the same row is
|
|
range(2), this object will be the starting VLAN ID of the range. Valid
|
|
range is 1-4095. This object can only be configured if VlanIdOp is not
|
|
any(0)."
|
|
::= { me1200QosQceTableRowEditor 12 }
|
|
|
|
me1200QosQceTableRowEditorVlanIdRange OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VLAN ID to be compared. If the VlanIdOp object in the same row is
|
|
range(2), this object will be the ending VLAN ID of the range. Valid
|
|
range is 1-4095. This object can only be configured if VlanIdOp is
|
|
range(2)."
|
|
::= { me1200QosQceTableRowEditor 13 }
|
|
|
|
me1200QosQceTableRowEditorPcp OBJECT-TYPE
|
|
SYNTAX ME1200VlanTagPriority
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PCP value(s) to be compared."
|
|
::= { me1200QosQceTableRowEditor 14 }
|
|
|
|
me1200QosQceTableRowEditorDei OBJECT-TYPE
|
|
SYNTAX ME1200BitType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DEI value to be compared. Valid range is 0-1."
|
|
::= { me1200QosQceTableRowEditor 15 }
|
|
|
|
me1200QosQceTableRowEditorInnerVlanTagType OBJECT-TYPE
|
|
SYNTAX ME1200VlanTagType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the inner VLAN tag type to match."
|
|
::= { me1200QosQceTableRowEditor 16 }
|
|
|
|
me1200QosQceTableRowEditorInnerVlanIdOp OBJECT-TYPE
|
|
SYNTAX ME1200ASRType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates how a packets's inner VLAN ID is to be compared."
|
|
::= { me1200QosQceTableRowEditor 17 }
|
|
|
|
me1200QosQceTableRowEditorInnerVlanId OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The inner VLAN ID to be compared. If the InnerVlanIdOp object in the
|
|
same row is range(2), this object will be the starting VLAN ID of the
|
|
range. Valid range is 1-4095. This object can only be configured if
|
|
InnerVlanIdOp is not any(0)."
|
|
::= { me1200QosQceTableRowEditor 18 }
|
|
|
|
me1200QosQceTableRowEditorInnerVlanIdRange OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The inner VLAN ID to be compared. If the InnerVlanIdOp object in the
|
|
same row is range(2), this object will be the ending VLAN ID of the
|
|
range. Valid range is 1-4095. This object can only be configured if
|
|
InnerVlanIdOp is range(2)."
|
|
::= { me1200QosQceTableRowEditor 19 }
|
|
|
|
me1200QosQceTableRowEditorInnerPcp OBJECT-TYPE
|
|
SYNTAX ME1200VlanTagPriority
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The inner PCP value(s) to be compared."
|
|
::= { me1200QosQceTableRowEditor 20 }
|
|
|
|
me1200QosQceTableRowEditorInnerDei OBJECT-TYPE
|
|
SYNTAX ME1200BitType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The inner DEI value to be compared. Valid range is 0-1."
|
|
::= { me1200QosQceTableRowEditor 21 }
|
|
|
|
me1200QosQceTableRowEditorFrameType OBJECT-TYPE
|
|
SYNTAX ME1200QceFrameType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the packet's frame type. Modifying the frame type on an
|
|
existing QCE will restore the content of all frame type dependent
|
|
configuration to default."
|
|
::= { me1200QosQceTableRowEditor 100 }
|
|
|
|
me1200QosQceTableRowEditorEtype OBJECT-TYPE
|
|
SYNTAX ME1200EtherType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the packet's 16 bit Ethernet type field. Valid values are:
|
|
0(match any), 0x600-0xFFFF but excluding 0x800(IPv4) and
|
|
0x86DD(IPv6).This object can only be configured if FrameType is
|
|
etype(1)."
|
|
::= { me1200QosQceTableRowEditor 101 }
|
|
|
|
me1200QosQceTableRowEditorLlcDsap OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the packets's 8 bit LLC DSAP field. The packets LLC DSAP
|
|
field is AND-ed with the value of LlcDsapMask and then compared against
|
|
the value of this object. If this object value and the value of
|
|
LlcDsapMask is 0x00, this entry matches any LLC DSAP. Valid range is
|
|
0x00-0xFF. This object can only be configured if FrameType is llc(2)."
|
|
::= { me1200QosQceTableRowEditor 200 }
|
|
|
|
me1200QosQceTableRowEditorLlcDsapMask OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the 8 bit LLC DSAP mask. Valid values are 0x00 or 0xFF. This
|
|
object can only be configured if FrameType is llc(2)."
|
|
::= { me1200QosQceTableRowEditor 201 }
|
|
|
|
me1200QosQceTableRowEditorLlcSsap OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the packets's 8 bit LLC SSAP field. The packets LLC SSAP
|
|
field is AND-ed with the value of LlcSsapMask and then compared against
|
|
the value of this object. If this object value and the value of
|
|
LlcSsapMask is 0x00, this entry matches any LLC SSAP. Valid range is
|
|
0x00-0xFF. This object can only be configured if FrameType is llc(2)."
|
|
::= { me1200QosQceTableRowEditor 202 }
|
|
|
|
me1200QosQceTableRowEditorLlcSsapMask OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the 8 bit LLC SSAP mask. Valid values are 0x00 or 0xFF. This
|
|
object can only be configured if FrameType is llc(2)."
|
|
::= { me1200QosQceTableRowEditor 203 }
|
|
|
|
me1200QosQceTableRowEditorLlcControl OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the packets's 8 bit LLC Control field. The packets LLC
|
|
Control field is AND-ed with the value of LlcControlMask and then
|
|
compared against the value of this object. If this object value and the
|
|
value of LlcControlMask is 0x00, this entry matches any LLC Control.
|
|
Valid range is 0x00-0xFF. This object can only be configured if
|
|
FrameType is llc(2)."
|
|
::= { me1200QosQceTableRowEditor 204 }
|
|
|
|
me1200QosQceTableRowEditorLlcControlMask OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the 8 bit LLC Control mask. Valid values are 0x00 or 0xFF.
|
|
This object can only be configured if FrameType is llc(2)."
|
|
::= { me1200QosQceTableRowEditor 205 }
|
|
|
|
me1200QosQceTableRowEditorSnapPid OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the packet's 16 bit SNAP PID field. The packets SNAP PID
|
|
field is AND-ed with the value of SnapPidMask and then compared against
|
|
the value of this object. If this object value and the value of
|
|
SnapPidMask is 0x0000, this entry matches any ethertype. This object
|
|
can only be configured if FrameType is snap(3)."
|
|
::= { me1200QosQceTableRowEditor 302 }
|
|
|
|
me1200QosQceTableRowEditorSnapPidMask OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the 16 bit SNAP PID mask. Valid values are 0x0000 or 0xFFFF.
|
|
This object can only be configured if FrameType is snap(3)."
|
|
::= { me1200QosQceTableRowEditor 303 }
|
|
|
|
me1200QosQceTableRowEditorIpv4Fragment OBJECT-TYPE
|
|
SYNTAX ME1200BitType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates how an IPv4 fragment bit is to be compared. This object can
|
|
only be configured if FrameType is ipv4(4)."
|
|
::= { me1200QosQceTableRowEditor 400 }
|
|
|
|
me1200QosQceTableRowEditorIpv4DscpOp OBJECT-TYPE
|
|
SYNTAX ME1200ASRType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates how an IPv4 DSCP field is to be compared. This object can
|
|
only be configured if FrameType is ipv4(4)."
|
|
::= { me1200QosQceTableRowEditor 401 }
|
|
|
|
me1200QosQceTableRowEditorIpv4Dscp OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DSCP value to be compared. If the Ipv4DscpOp object in the same row
|
|
is range(2), this object will be the starting DSCP value of the range.
|
|
Valid range is 0-63. This object can only be configured if FrameType is
|
|
ipv4(4) and Ipv4DscpOp is not any(0)."
|
|
::= { me1200QosQceTableRowEditor 402 }
|
|
|
|
me1200QosQceTableRowEditorIpv4DscpRange OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DSCP value to be compared. If the Ipv4DscpOp object in the same row
|
|
is range(2), this object will be the ending DSCP value of the range.
|
|
Valid range is 0-63. This object can only be configured if FrameType is
|
|
ipv4(4) and Ipv4DscpOp is range(2)."
|
|
::= { me1200QosQceTableRowEditor 403 }
|
|
|
|
me1200QosQceTableRowEditorIpv4Protocol OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The protocol number field in the IPv4 header used to indicate a higher
|
|
layer protocol. The packets protocol number field is AND-ed with the
|
|
value of Ipv4ProtocolMask and then compared with the value of this
|
|
object. If Ipv4Protocol and Ipv4protocolMask are 0, this entry matches
|
|
any IPv4 protocol. Valid range is 0-255. This object can only be
|
|
configured if FrameType is ipv4(4)."
|
|
::= { me1200QosQceTableRowEditor 404 }
|
|
|
|
me1200QosQceTableRowEditorIpv4ProtocolMask OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specified IPv4 protocol number mask. Valid values are 0 or 255.
|
|
This object can only be configured if FrameType is ipv4(4)."
|
|
::= { me1200QosQceTableRowEditor 405 }
|
|
|
|
me1200QosQceTableRowEditorIpv4SrcIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specified IPv4 source address. The packets source address is AND-ed
|
|
with the value of Ipv4SrcIpMask and then compared with the value of
|
|
this object. If Ipv4SrcIP and Ipv4SrcIpMask are 0.0.0.0, this entry
|
|
matches any IPv4 source address. This object can only be configured if
|
|
FrameType is ipv4(4)."
|
|
::= { me1200QosQceTableRowEditor 406 }
|
|
|
|
me1200QosQceTableRowEditorIpv4SrcIpMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specified IPv4 source address mask. This object can only be
|
|
configured if FrameType is ipv4(4)."
|
|
::= { me1200QosQceTableRowEditor 407 }
|
|
|
|
me1200QosQceTableRowEditorIpv4DestIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specified IPv4 destination address. The packets destination address
|
|
is AND-ed with the value of Ipv4DestIpMask and then compared with the
|
|
value of this object. If Ipv4DestIP and Ipv4DestIpMask are 0.0.0.0,
|
|
this entry matches any IPv4 destination address. This object can only
|
|
be configured if FrameType is ipv4(4)."
|
|
::= { me1200QosQceTableRowEditor 408 }
|
|
|
|
me1200QosQceTableRowEditorIpv4DestIpMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specified IPv4 destination address mask. This object can only be
|
|
configured if FrameType is ipv4(4)."
|
|
::= { me1200QosQceTableRowEditor 409 }
|
|
|
|
me1200QosQceTableRowEditorIpv4SrcPortOp OBJECT-TYPE
|
|
SYNTAX ME1200ASRType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates how a packet's source TCP/UDP port number is to be compared.
|
|
This object can only be configured if FrameType is ipv4(4)."
|
|
::= { me1200QosQceTableRowEditor 410 }
|
|
|
|
me1200QosQceTableRowEditorIpv4SrcPort OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source port number of the TCP or UDP protocol. If the Ipv4SrcPortOp
|
|
object in the same row is range(2), this object will be the starting
|
|
port number of the port range. Valid range is 0-65535. This object can
|
|
only be configured if FrameType is ipv4(4) and Ipv4SrcPortOp is not
|
|
any(0)."
|
|
::= { me1200QosQceTableRowEditor 411 }
|
|
|
|
me1200QosQceTableRowEditorIpv4SrcPortRange OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source port number of the TCP or UDP protocol. If the Ipv4SrcPortOp
|
|
object in the same row is range(2), this object will be the ending port
|
|
number of the port range. Valid range is 0-65535. This object can only
|
|
be configured if FrameType is ipv4(4) and Ipv4SrcPortOp is range(2)."
|
|
::= { me1200QosQceTableRowEditor 412 }
|
|
|
|
me1200QosQceTableRowEditorIpv4DestPortOp OBJECT-TYPE
|
|
SYNTAX ME1200ASRType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates how a packet's destination TCP/UDP port number is to be
|
|
compared. This object can only be configured if FrameType is ipv4(4)."
|
|
::= { me1200QosQceTableRowEditor 413 }
|
|
|
|
me1200QosQceTableRowEditorIpv4DestPort OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The destination port number of the TCP or UDP protocol. If the
|
|
Ipv4DestPortOp object in the same row is range(2), this object will be
|
|
the starting port number of the port range. Valid range is 0-65535.
|
|
This object can only be configured if FrameType is ipv4(4) and
|
|
Ipv4DestPortOp is not any(0)."
|
|
::= { me1200QosQceTableRowEditor 414 }
|
|
|
|
me1200QosQceTableRowEditorIpv4DestPortRange OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source port number of the TCP or UDP protocol. If the
|
|
Ipv4DestPortOp object in the same row is range(2), this object will be
|
|
the ending port number of the port range. Valid range is 0-65535. This
|
|
object can only be configured if FrameType is ipv4(4) and
|
|
Ipv4DestPortOp is range(2)."
|
|
::= { me1200QosQceTableRowEditor 415 }
|
|
|
|
me1200QosQceTableRowEditorIpv6DscpOp OBJECT-TYPE
|
|
SYNTAX ME1200ASRType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates how an IPv6 DSCP field is to be compared. This object can
|
|
only be configured if FrameType is ipv6(5)."
|
|
::= { me1200QosQceTableRowEditor 500 }
|
|
|
|
me1200QosQceTableRowEditorIpv6Dscp OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DSCP value to be compared. If the Ipv6DscpOp object in the same row
|
|
is range(2), this object will be the starting DSCP value of the range.
|
|
Valid range is 0-63. This object can only be configured if FrameType is
|
|
ipv6(5) and Ipv6DscpOp is not any(0)."
|
|
::= { me1200QosQceTableRowEditor 501 }
|
|
|
|
me1200QosQceTableRowEditorIpv6DscpRange OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DSCP value to be compared. If the Ipv6DscpOp object in the same row
|
|
is range(2), this object will be the ending DSCP value of the range.
|
|
Valid range is 0-63. This object can only be configured if FrameType is
|
|
ipv6(5) and Ipv6DscpOp is range(2)."
|
|
::= { me1200QosQceTableRowEditor 502 }
|
|
|
|
me1200QosQceTableRowEditorIpv6Protocol OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The protocol number field in the IPv6 header used to indicate a higher
|
|
layer protocol. The packets protocol number field is AND-ed with the
|
|
value of Ipv6ProtocolMask and then compared with the value of this
|
|
object. If Ipv46rotocol and Ipv6protocolMask are 0, this entry matches
|
|
any IPv6 protocol. Valid range is 0-255. This object can only be
|
|
configured if FrameType is ipv6(5)."
|
|
::= { me1200QosQceTableRowEditor 503 }
|
|
|
|
me1200QosQceTableRowEditorIpv6ProtocolMask OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specified IPv6 protocol number mask. Valid values are 0 or 255.
|
|
This object can only be configured if FrameType is ipv6(5)."
|
|
::= { me1200QosQceTableRowEditor 504 }
|
|
|
|
me1200QosQceTableRowEditorIpv6SrcIp OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specified IPv6 source address. The packets source address is AND-ed
|
|
with the value of Ipv6SrcIpMask and then compared with the value of
|
|
this object. If Ipv6SrcIP and Ipv6SrcIpMask are all zeros, this entry
|
|
matches any IPv6 source address. Only the least significant 32 bits of
|
|
this object are used. This object can only be configured if FrameType
|
|
is ipv6(5)."
|
|
::= { me1200QosQceTableRowEditor 506 }
|
|
|
|
me1200QosQceTableRowEditorIpv6SrcIpMask OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specified IPv6 source address mask. Only the least significant 32
|
|
bits of this object are used. This object can only be configured if
|
|
FrameType is ipv6(5)."
|
|
::= { me1200QosQceTableRowEditor 508 }
|
|
|
|
me1200QosQceTableRowEditorIpv6DestIp OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specified IPv6 destination address. The packets destination address
|
|
is AND-ed with the value of Ipv6DestIpMask and then compared with the
|
|
value of this object. If Ipv6DestIP and Ipv6DestIpMask are all zeros,
|
|
this entry matches any IPv6 destination address. Only the least
|
|
significant 32 bits of this object are used. This object can only be
|
|
configured if FrameType is ipv6(5)."
|
|
::= { me1200QosQceTableRowEditor 510 }
|
|
|
|
me1200QosQceTableRowEditorIpv6DestIpMask OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specified IPv6 destination address mask. Only the least significant
|
|
32 bits of this object are used. This object can only be configured if
|
|
FrameType is ipv6(5)."
|
|
::= { me1200QosQceTableRowEditor 512 }
|
|
|
|
me1200QosQceTableRowEditorIpv6SrcPortOp OBJECT-TYPE
|
|
SYNTAX ME1200ASRType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates how a packet's source TCP/UDP port number is to be compared.
|
|
This object can only be configured if FrameType is ipv6(5)."
|
|
::= { me1200QosQceTableRowEditor 513 }
|
|
|
|
me1200QosQceTableRowEditorIpv6SrcPort OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source port number of the TCP or UDP protocol. If the Ipv6SrcPortOp
|
|
object in the same row is range(2), this object will be the starting
|
|
port number of the port range. Valid range is 0-65535. This object can
|
|
only be configured if FrameType is ipv6(5) and Ipv6SrcPortOp is not
|
|
any(0)."
|
|
::= { me1200QosQceTableRowEditor 514 }
|
|
|
|
me1200QosQceTableRowEditorIpv6SrcPortRange OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source port number of the TCP or UDP protocol. If the Ipv6SrcPortOp
|
|
object in the same row is range(2), this object will be the ending port
|
|
number of the port range. Valid range is 0-65535. This object can only
|
|
be configured if FrameType is ipv6(5) and Ipv6SrcPortOp is range(2)."
|
|
::= { me1200QosQceTableRowEditor 515 }
|
|
|
|
me1200QosQceTableRowEditorIpv6DestPortOp OBJECT-TYPE
|
|
SYNTAX ME1200ASRType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates how a packet's destination TCP/UDP port number is to be
|
|
compared. This object can only be configured if FrameType is ipv6(5)."
|
|
::= { me1200QosQceTableRowEditor 516 }
|
|
|
|
me1200QosQceTableRowEditorIpv6DestPort OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The destination port number of the TCP or UDP protocol. If the
|
|
Ipv6DestPortOp object in the same row is range(2), this object will be
|
|
the starting port number of the port range. Valid range is 0-65535.
|
|
This object can only be configured if FrameType is ipv6(5) and
|
|
Ipv6DestPortOp is not any(0)."
|
|
::= { me1200QosQceTableRowEditor 517 }
|
|
|
|
me1200QosQceTableRowEditorIpv6DestPortRange OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source port number of the TCP or UDP protocol. If the
|
|
Ipv6DestPortOp object in the same row is range(2), this object will be
|
|
the ending port number of the port range. Valid range is 0-65535. This
|
|
object can only be configured if FrameType is ipv6(5) and
|
|
Ipv6DestPortOp is range(2)."
|
|
::= { me1200QosQceTableRowEditor 518 }
|
|
|
|
me1200QosQceTableRowEditorActionCosEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the packet is classified to the CoS value in ActionCos."
|
|
::= { me1200QosQceTableRowEditor 1000 }
|
|
|
|
me1200QosQceTableRowEditorActionCos OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CoS value used for classification. Valid range is 0-7."
|
|
::= { me1200QosQceTableRowEditor 1001 }
|
|
|
|
me1200QosQceTableRowEditorActionDplEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the packet is classified to the DPL value in ActionDpl."
|
|
::= { me1200QosQceTableRowEditor 1002 }
|
|
|
|
me1200QosQceTableRowEditorActionDpl OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DPL value used for classification. Valid range is 0-1."
|
|
::= { me1200QosQceTableRowEditor 1003 }
|
|
|
|
me1200QosQceTableRowEditorActionDscpEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the packet is classified to the DSCP value in ActionDscp."
|
|
::= { me1200QosQceTableRowEditor 1004 }
|
|
|
|
me1200QosQceTableRowEditorActionDscp OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DSCP value used for classification. Valid range is 0-1."
|
|
::= { me1200QosQceTableRowEditor 1005 }
|
|
|
|
me1200QosQceTableRowEditorActionPcpDeiEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the packet is classified to the PCP value in ActionPcp and the
|
|
DEI value in ActionDei."
|
|
::= { me1200QosQceTableRowEditor 1006 }
|
|
|
|
me1200QosQceTableRowEditorActionPcp OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PCP value used for classification. Valid range is 0-7."
|
|
::= { me1200QosQceTableRowEditor 1007 }
|
|
|
|
me1200QosQceTableRowEditorActionDei OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DEI value used for classification. Valid range is 0-1."
|
|
::= { me1200QosQceTableRowEditor 1008 }
|
|
|
|
me1200QosQceTableRowEditorActionPolicyEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the packet is classified to the policy number in ActionPolicy."
|
|
::= { me1200QosQceTableRowEditor 1009 }
|
|
|
|
me1200QosQceTableRowEditorActionPolicy OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The policy number used for classification. Valid range is 0-63."
|
|
::= { me1200QosQceTableRowEditor 1010 }
|
|
|
|
me1200QosQceTableRowEditorAction OBJECT-TYPE
|
|
SYNTAX ME1200RowEditorState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Action"
|
|
::= { me1200QosQceTableRowEditor 10000 }
|
|
|
|
me1200QosQcePrecedenceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200QosQcePrecedenceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the precedence of QCEs ordered by their position in
|
|
the QCL."
|
|
::= { me1200QosQce 3 }
|
|
|
|
me1200QosQcePrecedenceEntry OBJECT-TYPE
|
|
SYNTAX ME1200QosQcePrecedenceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row contains the precedence of a single QCE."
|
|
INDEX { me1200QosQcePrecedenceIndex }
|
|
::= { me1200QosQcePrecedenceTable 1 }
|
|
|
|
ME1200QosQcePrecedenceEntry ::= SEQUENCE {
|
|
me1200QosQcePrecedenceIndex Integer32,
|
|
me1200QosQcePrecedenceQceId Unsigned32
|
|
}
|
|
|
|
me1200QosQcePrecedenceIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"QCE precedence index. Indicates the position in QCL."
|
|
::= { me1200QosQcePrecedenceEntry 1 }
|
|
|
|
me1200QosQcePrecedenceQceId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"QCE Id."
|
|
::= { me1200QosQcePrecedenceEntry 2 }
|
|
|
|
me1200QosInterface OBJECT IDENTIFIER
|
|
::= { me1200QosConfig 2 }
|
|
|
|
me1200QosIfConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200QosIfConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides QoS configuration for QoS manageable interfaces"
|
|
::= { me1200QosInterface 1 }
|
|
|
|
me1200QosIfConfigEntry OBJECT-TYPE
|
|
SYNTAX ME1200QosIfConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row contains the configuration for a specific interface"
|
|
INDEX { me1200QosIfConfigIfIndex }
|
|
::= { me1200QosIfConfigTable 1 }
|
|
|
|
ME1200QosIfConfigEntry ::= SEQUENCE {
|
|
me1200QosIfConfigIfIndex ME1200InterfaceIndex,
|
|
me1200QosIfConfigCos Unsigned32,
|
|
me1200QosIfConfigDpl ME1200Unsigned8,
|
|
me1200QosIfConfigPcp Unsigned32,
|
|
me1200QosIfConfigDei ME1200Unsigned8,
|
|
me1200QosIfConfigTrustTag TruthValue,
|
|
me1200QosIfConfigTrustDscp TruthValue,
|
|
me1200QosIfConfigDwrrCount ME1200Unsigned8,
|
|
me1200QosIfConfigTagRemarkingMode ME1200TagRemarkingMode,
|
|
me1200QosIfConfigTagPcp Unsigned32,
|
|
me1200QosIfConfigTagDei ME1200Unsigned8,
|
|
me1200QosIfConfigDscpTranslate TruthValue,
|
|
me1200QosIfConfigDscpClassify ME1200DscpClassify,
|
|
me1200QosIfConfigDscpRemark ME1200DscpRemark,
|
|
me1200QosIfConfigQceAddressMode TruthValue,
|
|
me1200QosIfConfigQceKeyType ME1200VcapKeyType
|
|
}
|
|
|
|
me1200QosIfConfigIfIndex OBJECT-TYPE
|
|
SYNTAX ME1200InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical interface index."
|
|
::= { me1200QosIfConfigEntry 1 }
|
|
|
|
me1200QosIfConfigCos OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The default CoS value a packet is classified to. Valid range is 0-7."
|
|
::= { me1200QosIfConfigEntry 2 }
|
|
|
|
me1200QosIfConfigDpl OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The default DPL (Drop Precedence Level) a packet is classified to.
|
|
Valid range is 0-1."
|
|
::= { me1200QosIfConfigEntry 3 }
|
|
|
|
me1200QosIfConfigPcp OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The default PCP value a packet is classified to. Valid range is 0-7."
|
|
::= { me1200QosIfConfigEntry 4 }
|
|
|
|
me1200QosIfConfigDei OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The default DEI value a packet is classified to. Valid range is 0-1."
|
|
::= { me1200QosIfConfigEntry 5 }
|
|
|
|
me1200QosIfConfigTrustTag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true and the packet is VLAN tagged, then the CoS and DPL assigned to
|
|
the packet is the PCP and DEI value in the packet mapped to a CoS and
|
|
DPL value defined in the qosTagToCosTable."
|
|
::= { me1200QosIfConfigEntry 6 }
|
|
|
|
me1200QosIfConfigTrustDscp OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true and the packet type is IPv4 or IPv6 and the packet DSCP value
|
|
is trusted in qosDscpTable, then the CoS and DPL assigned to the packet
|
|
is the DSCP value in the packet mapped to a CoS and DPL value defined
|
|
in the qosDscpTable."
|
|
::= { me1200QosIfConfigEntry 7 }
|
|
|
|
me1200QosIfConfigDwrrCount OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of queues that are running Deficit Weighted Round Robin
|
|
scheduling. This value is restricted to 0 or 6."
|
|
::= { me1200QosIfConfigEntry 8 }
|
|
|
|
me1200QosIfConfigTagRemarkingMode OBJECT-TYPE
|
|
SYNTAX ME1200TagRemarkingMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selects the tag remarking mode for egress. Valid values are:
|
|
|
|
'classified' : Remark the tag with the classified values of PCP and
|
|
DEI.
|
|
|
|
'default' : Remark the tag with the configured TagPcp and TagDei.
|
|
|
|
'mapped' : Remark the tag with the values from the classified CoS and
|
|
DPL mapped through the qosCosToTagTable"
|
|
::= { me1200QosIfConfigEntry 9 }
|
|
|
|
me1200QosIfConfigTagPcp OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PCP value to put in the packet if TagRemarkingMode is set to
|
|
'default'. Valid range is 0-7."
|
|
::= { me1200QosIfConfigEntry 10 }
|
|
|
|
me1200QosIfConfigTagDei OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DEI value to put in the packet if TagRemarkingMode is set to
|
|
'default'. Valid range is 0-1."
|
|
::= { me1200QosIfConfigEntry 11 }
|
|
|
|
me1200QosIfConfigDscpTranslate OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true then the classified DSCP value is the DSCP value in the packed
|
|
mapped to a new DSCP value defined in qosDscpTable.IngressTranslation."
|
|
::= { me1200QosIfConfigEntry 12 }
|
|
|
|
me1200QosIfConfigDscpClassify OBJECT-TYPE
|
|
SYNTAX ME1200DscpClassify
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selects if and how the classified DSCP is based on the classified CoS
|
|
and DPL for IPv4 and IPv6 packets on ingress.
|
|
|
|
If a packet is selected for being classified to a new DSCP, the
|
|
classification in based on the classified CoS mapped to a new DSCP
|
|
value through the qosCosToDscpTable. If the classified DPL is 1, the
|
|
new DSCP value is taken from the DscpDp1 entry, otherwise it is taken
|
|
from the Dscp entry. Valid values are:
|
|
|
|
'none' : Always classify to the DSCP value in the received packet and
|
|
ignore the classified CoS and DPL.
|
|
|
|
'zero' : If the DSCP value in the received packet is 0, then classify
|
|
to a new DSCP value based on the classified CoS and DPL.
|
|
|
|
'selected' : If the DSCP value in the received packet is enabled in
|
|
qosDscpTable.Classify, then classify to a new DSCP value based on the
|
|
classified CoS and DPL.
|
|
|
|
'all' : Always classify to a new DSCP value based on the classified CoS
|
|
and DPL.
|
|
|
|
"
|
|
::= { me1200QosIfConfigEntry 13 }
|
|
|
|
me1200QosIfConfigDscpRemark OBJECT-TYPE
|
|
SYNTAX ME1200DscpRemark
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selects if and how the classified DSCP is written into the packet at
|
|
egress. Valid values are:
|
|
|
|
'disabled' : Do not write the classified DSCP into the packet.
|
|
|
|
'rewrite' : Write the classified DSCP into the packet.
|
|
|
|
'remap' : Remap the classified DSCP through qosDscpTable, and write the
|
|
value from EgressTranslation into the packet.
|
|
|
|
'remap-dp' : Remap the classified DSCP through qosDscpTable. If the
|
|
classified DPL is 0 then write the value from EgressTranslation into
|
|
the packet, otherwise write the value from EgressTranslationDp1 into
|
|
the packet.
|
|
|
|
"
|
|
::= { me1200QosIfConfigEntry 14 }
|
|
|
|
me1200QosIfConfigQceAddressMode OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If false, the QCE classification for this interface is based on source
|
|
(SMAC/SIP) addresses. If true, the QCE classification for this
|
|
interface is based on destination (DMAC/DIP) addresses. This parameter
|
|
is only used when the QceKeyType is Normal."
|
|
::= { me1200QosIfConfigEntry 15 }
|
|
|
|
me1200QosIfConfigQceKeyType OBJECT-TYPE
|
|
SYNTAX ME1200VcapKeyType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The key type specifying the key generated for packets received on the
|
|
interface. Valid values are:
|
|
|
|
'normal' : Half key, match outer tag, SIP and SMAC.
|
|
|
|
'double-tag' : Quarter key, match inner and outer tag.
|
|
|
|
'ip-addr' : Half key, match inner and outer tag, SIP and DIP. For
|
|
non-IP frames, match outer tag only.
|
|
|
|
'mac-ip-addr' : Full key, match inner and outer tag, SMAC, DMAC, SIP
|
|
and DIP.
|
|
|
|
Filtering on DMAC type (unicast/multicast/broadcast) is supported for
|
|
any key type."
|
|
::= { me1200QosIfConfigEntry 16 }
|
|
|
|
me1200QosIfTagToCosTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200QosIfTagToCosEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the mapping of (interface, PCP, DEI) to (CoS, DPL)
|
|
values.The mappings given by this table is used for all tagged packets
|
|
received on an interface if and only if that interface has the value of
|
|
TrustTag set to 'true'"
|
|
::= { me1200QosInterface 2 }
|
|
|
|
me1200QosIfTagToCosEntry OBJECT-TYPE
|
|
SYNTAX ME1200QosIfTagToCosEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row contains the mapping from (interface, PCP, DEI) to (CoS, DPL)
|
|
values."
|
|
INDEX { me1200QosIfTagToCosIfIndex, me1200QosIfTagToCosPcp, me1200QosIfTagToCosDei }
|
|
::= { me1200QosIfTagToCosTable 1 }
|
|
|
|
ME1200QosIfTagToCosEntry ::= SEQUENCE {
|
|
me1200QosIfTagToCosIfIndex ME1200InterfaceIndex,
|
|
me1200QosIfTagToCosPcp Integer32,
|
|
me1200QosIfTagToCosDei Integer32,
|
|
me1200QosIfTagToCosCos Unsigned32,
|
|
me1200QosIfTagToCosDpl ME1200Unsigned8
|
|
}
|
|
|
|
me1200QosIfTagToCosIfIndex OBJECT-TYPE
|
|
SYNTAX ME1200InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical interface index."
|
|
::= { me1200QosIfTagToCosEntry 1 }
|
|
|
|
me1200QosIfTagToCosPcp OBJECT-TYPE
|
|
SYNTAX Integer32 (0..7)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PCP index."
|
|
::= { me1200QosIfTagToCosEntry 2 }
|
|
|
|
me1200QosIfTagToCosDei OBJECT-TYPE
|
|
SYNTAX Integer32 (0..1)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DEI index."
|
|
::= { me1200QosIfTagToCosEntry 3 }
|
|
|
|
me1200QosIfTagToCosCos OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CoS value which this entry maps to. Valid range is 0-7."
|
|
::= { me1200QosIfTagToCosEntry 4 }
|
|
|
|
me1200QosIfTagToCosDpl OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DPL (Drop Precedence Level) value which this entry maps to. Valid
|
|
range is 0-1."
|
|
::= { me1200QosIfTagToCosEntry 5 }
|
|
|
|
me1200QosIfCosToTagTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200QosIfCosToTagEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the mapping of (interface, CoS, DPL) to (PCP, DEI)
|
|
values.The mappings given by this table is used for packets transmitted
|
|
on an interface if and only if that interface has the value of
|
|
TagRemarkingMode set to 'mapped'"
|
|
::= { me1200QosInterface 3 }
|
|
|
|
me1200QosIfCosToTagEntry OBJECT-TYPE
|
|
SYNTAX ME1200QosIfCosToTagEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row contains the mapping from (interface, CoS, DPL) to (PCP, DEI)
|
|
values."
|
|
INDEX { me1200QosIfCosToTagIfIndex, me1200QosIfCosToTagCos, me1200QosIfCosToTagDpl }
|
|
::= { me1200QosIfCosToTagTable 1 }
|
|
|
|
ME1200QosIfCosToTagEntry ::= SEQUENCE {
|
|
me1200QosIfCosToTagIfIndex ME1200InterfaceIndex,
|
|
me1200QosIfCosToTagCos Integer32,
|
|
me1200QosIfCosToTagDpl Integer32,
|
|
me1200QosIfCosToTagPcp Unsigned32,
|
|
me1200QosIfCosToTagDei ME1200Unsigned8
|
|
}
|
|
|
|
me1200QosIfCosToTagIfIndex OBJECT-TYPE
|
|
SYNTAX ME1200InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical interface index."
|
|
::= { me1200QosIfCosToTagEntry 1 }
|
|
|
|
me1200QosIfCosToTagCos OBJECT-TYPE
|
|
SYNTAX Integer32 (0..7)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CoS index."
|
|
::= { me1200QosIfCosToTagEntry 2 }
|
|
|
|
me1200QosIfCosToTagDpl OBJECT-TYPE
|
|
SYNTAX Integer32 (0..3)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DPL index."
|
|
::= { me1200QosIfCosToTagEntry 3 }
|
|
|
|
me1200QosIfCosToTagPcp OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PCP value which this entry maps to. Valid range is 0-7."
|
|
::= { me1200QosIfCosToTagEntry 4 }
|
|
|
|
me1200QosIfCosToTagDei OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DEI value which this entry maps to. Valid range is 0-1."
|
|
::= { me1200QosIfCosToTagEntry 5 }
|
|
|
|
me1200QosIfPolicerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200QosIfPolicerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides policer configuration for an interface"
|
|
::= { me1200QosInterface 4 }
|
|
|
|
me1200QosIfPolicerEntry OBJECT-TYPE
|
|
SYNTAX ME1200QosIfPolicerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row contains the configuration for a specific policer"
|
|
INDEX { me1200QosIfPolicerIfIndex }
|
|
::= { me1200QosIfPolicerTable 1 }
|
|
|
|
ME1200QosIfPolicerEntry ::= SEQUENCE {
|
|
me1200QosIfPolicerIfIndex ME1200InterfaceIndex,
|
|
me1200QosIfPolicerEnable TruthValue,
|
|
me1200QosIfPolicerFrameRate TruthValue,
|
|
me1200QosIfPolicerFlowControl TruthValue,
|
|
me1200QosIfPolicerCir Unsigned32
|
|
}
|
|
|
|
me1200QosIfPolicerIfIndex OBJECT-TYPE
|
|
SYNTAX ME1200InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical interface index."
|
|
::= { me1200QosIfPolicerEntry 1 }
|
|
|
|
me1200QosIfPolicerEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the port policer is enabled."
|
|
::= { me1200QosIfPolicerEntry 2 }
|
|
|
|
me1200QosIfPolicerFrameRate OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the rate is measured in fps instead of kbps."
|
|
::= { me1200QosIfPolicerEntry 3 }
|
|
|
|
me1200QosIfPolicerFlowControl OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, and flow control is enabled on the interface, then issue flow
|
|
control pause frames instead of discarding frames."
|
|
::= { me1200QosIfPolicerEntry 4 }
|
|
|
|
me1200QosIfPolicerCir OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Committed Information Rate. Measured in kbps if FrameRate is false and
|
|
fps if FrameRate is true. Valid range is 100-3300000."
|
|
::= { me1200QosIfPolicerEntry 5 }
|
|
|
|
me1200QosIfQueuePolicerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200QosIfQueuePolicerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides queue policer configuration for interfaces"
|
|
::= { me1200QosInterface 5 }
|
|
|
|
me1200QosIfQueuePolicerEntry OBJECT-TYPE
|
|
SYNTAX ME1200QosIfQueuePolicerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row contains the configuration for a specific queue policer"
|
|
INDEX { me1200QosIfQueuePolicerIfIndex, me1200QosIfQueuePolicerQueue }
|
|
::= { me1200QosIfQueuePolicerTable 1 }
|
|
|
|
ME1200QosIfQueuePolicerEntry ::= SEQUENCE {
|
|
me1200QosIfQueuePolicerIfIndex ME1200InterfaceIndex,
|
|
me1200QosIfQueuePolicerQueue Integer32,
|
|
me1200QosIfQueuePolicerEnable TruthValue,
|
|
me1200QosIfQueuePolicerCir Unsigned32
|
|
}
|
|
|
|
me1200QosIfQueuePolicerIfIndex OBJECT-TYPE
|
|
SYNTAX ME1200InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical interface index."
|
|
::= { me1200QosIfQueuePolicerEntry 1 }
|
|
|
|
me1200QosIfQueuePolicerQueue OBJECT-TYPE
|
|
SYNTAX Integer32 (0..7)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Queue index."
|
|
::= { me1200QosIfQueuePolicerEntry 2 }
|
|
|
|
me1200QosIfQueuePolicerEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the queue policer is enabled."
|
|
::= { me1200QosIfQueuePolicerEntry 3 }
|
|
|
|
me1200QosIfQueuePolicerCir OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Committed Information Rate. Measured in kbps. Valid range is
|
|
100-3300000."
|
|
::= { me1200QosIfQueuePolicerEntry 6 }
|
|
|
|
me1200QosIfShaperTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200QosIfShaperEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides shaper configuration for an interface"
|
|
::= { me1200QosInterface 6 }
|
|
|
|
me1200QosIfShaperEntry OBJECT-TYPE
|
|
SYNTAX ME1200QosIfShaperEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row contains the configuration for a specific shaper"
|
|
INDEX { me1200QosIfShaperIfIndex }
|
|
::= { me1200QosIfShaperTable 1 }
|
|
|
|
ME1200QosIfShaperEntry ::= SEQUENCE {
|
|
me1200QosIfShaperIfIndex ME1200InterfaceIndex,
|
|
me1200QosIfShaperEnable TruthValue,
|
|
me1200QosIfShaperCir Unsigned32
|
|
}
|
|
|
|
me1200QosIfShaperIfIndex OBJECT-TYPE
|
|
SYNTAX ME1200InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical interface index."
|
|
::= { me1200QosIfShaperEntry 1 }
|
|
|
|
me1200QosIfShaperEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the port shaper is enabled."
|
|
::= { me1200QosIfShaperEntry 2 }
|
|
|
|
me1200QosIfShaperCir OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Committed Information Rate. Measured in kbps. Valid range is
|
|
100-3300000."
|
|
::= { me1200QosIfShaperEntry 3 }
|
|
|
|
me1200QosIfQueueShaperTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200QosIfQueueShaperEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides queue shaper configuration for interfaces"
|
|
::= { me1200QosInterface 7 }
|
|
|
|
me1200QosIfQueueShaperEntry OBJECT-TYPE
|
|
SYNTAX ME1200QosIfQueueShaperEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row contains the configuration for a specific queue shaper"
|
|
INDEX { me1200QosIfQueueShaperIfIndex, me1200QosIfQueueShaperQueue }
|
|
::= { me1200QosIfQueueShaperTable 1 }
|
|
|
|
ME1200QosIfQueueShaperEntry ::= SEQUENCE {
|
|
me1200QosIfQueueShaperIfIndex ME1200InterfaceIndex,
|
|
me1200QosIfQueueShaperQueue Integer32,
|
|
me1200QosIfQueueShaperEnable TruthValue,
|
|
me1200QosIfQueueShaperExcess TruthValue,
|
|
me1200QosIfQueueShaperCir Unsigned32
|
|
}
|
|
|
|
me1200QosIfQueueShaperIfIndex OBJECT-TYPE
|
|
SYNTAX ME1200InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical interface index."
|
|
::= { me1200QosIfQueueShaperEntry 1 }
|
|
|
|
me1200QosIfQueueShaperQueue OBJECT-TYPE
|
|
SYNTAX Integer32 (0..7)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Queue index."
|
|
::= { me1200QosIfQueueShaperEntry 2 }
|
|
|
|
me1200QosIfQueueShaperEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the queue shaper is enabled."
|
|
::= { me1200QosIfQueueShaperEntry 3 }
|
|
|
|
me1200QosIfQueueShaperExcess OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, then allow this queue to get a share of the excess bandwidth.
|
|
Excess bandwidth is allowed if this shaper is closed and no other
|
|
queues with open shapers have frames for transmission."
|
|
::= { me1200QosIfQueueShaperEntry 4 }
|
|
|
|
me1200QosIfQueueShaperCir OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Committed Information Rate. Measured in kbps. Valid range is
|
|
100-3300000."
|
|
::= { me1200QosIfQueueShaperEntry 5 }
|
|
|
|
me1200QosIfSchedulerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200QosIfSchedulerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the mapping of (interface, queue) to weight
|
|
values.The mappings given by this table is used when an interface has
|
|
the value of DwrrCount greater than 0. Read the qosSchedulerStatusTable
|
|
in order to get the 'real' weights in percent as used by the hardware"
|
|
::= { me1200QosInterface 8 }
|
|
|
|
me1200QosIfSchedulerEntry OBJECT-TYPE
|
|
SYNTAX ME1200QosIfSchedulerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row contains the scheduler configuration for a specific queue."
|
|
INDEX { me1200QosIfSchedulerIfIndex, me1200QosIfSchedulerQueue }
|
|
::= { me1200QosIfSchedulerTable 1 }
|
|
|
|
ME1200QosIfSchedulerEntry ::= SEQUENCE {
|
|
me1200QosIfSchedulerIfIndex ME1200InterfaceIndex,
|
|
me1200QosIfSchedulerQueue Integer32,
|
|
me1200QosIfSchedulerWeight ME1200Percent
|
|
}
|
|
|
|
me1200QosIfSchedulerIfIndex OBJECT-TYPE
|
|
SYNTAX ME1200InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical interface index."
|
|
::= { me1200QosIfSchedulerEntry 1 }
|
|
|
|
me1200QosIfSchedulerQueue OBJECT-TYPE
|
|
SYNTAX Integer32 (0..7)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Queue index."
|
|
::= { me1200QosIfSchedulerEntry 2 }
|
|
|
|
me1200QosIfSchedulerWeight OBJECT-TYPE
|
|
SYNTAX ME1200Percent
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The weight for this queue. Valid range is 1-100."
|
|
::= { me1200QosIfSchedulerEntry 3 }
|
|
|
|
me1200QosStatus OBJECT IDENTIFIER
|
|
::= { me1200QosMIBObjects 3 }
|
|
|
|
me1200QosStatusGlobals OBJECT IDENTIFIER
|
|
::= { me1200QosStatus 1 }
|
|
|
|
me1200QosStatusQceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200QosStatusQceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the QCE status in the hardware table."
|
|
::= { me1200QosStatusGlobals 1 }
|
|
|
|
me1200QosStatusQceEntry OBJECT-TYPE
|
|
SYNTAX ME1200QosStatusQceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row contains the status of a single QCE."
|
|
INDEX { me1200QosStatusQceIndex }
|
|
::= { me1200QosStatusQceTable 1 }
|
|
|
|
ME1200QosStatusQceEntry ::= SEQUENCE {
|
|
me1200QosStatusQceIndex Integer32,
|
|
me1200QosStatusQceUserId ME1200QceUserType,
|
|
me1200QosStatusQceQceId Unsigned32,
|
|
me1200QosStatusQceConflict TruthValue
|
|
}
|
|
|
|
me1200QosStatusQceIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"QCE precedence index. Indicates the position in QCL."
|
|
::= { me1200QosStatusQceEntry 2 }
|
|
|
|
me1200QosStatusQceUserId OBJECT-TYPE
|
|
SYNTAX ME1200QceUserType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"User Id."
|
|
::= { me1200QosStatusQceEntry 3 }
|
|
|
|
me1200QosStatusQceQceId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"QCE Id."
|
|
::= { me1200QosStatusQceEntry 4 }
|
|
|
|
me1200QosStatusQceConflict OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, a resource conflict is detected."
|
|
::= { me1200QosStatusQceEntry 100 }
|
|
|
|
me1200QosStatusInterface OBJECT IDENTIFIER
|
|
::= { me1200QosStatus 2 }
|
|
|
|
me1200QosStatusIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200QosStatusIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides QoS status for QoS manageable interfaces"
|
|
::= { me1200QosStatusInterface 1 }
|
|
|
|
me1200QosStatusIfEntry OBJECT-TYPE
|
|
SYNTAX ME1200QosStatusIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row contains the status for a specific interface"
|
|
INDEX { me1200QosStatusIfIfIndex }
|
|
::= { me1200QosStatusIfTable 1 }
|
|
|
|
ME1200QosStatusIfEntry ::= SEQUENCE {
|
|
me1200QosStatusIfIfIndex ME1200InterfaceIndex,
|
|
me1200QosStatusIfCos Unsigned32
|
|
}
|
|
|
|
me1200QosStatusIfIfIndex OBJECT-TYPE
|
|
SYNTAX ME1200InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical interface index."
|
|
::= { me1200QosStatusIfEntry 1 }
|
|
|
|
me1200QosStatusIfCos OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Some subsystems are allowed to modify the default CoS value for an
|
|
interface. This object shows the actual default CoS value a packet is
|
|
classified to."
|
|
::= { me1200QosStatusIfEntry 2 }
|
|
|
|
me1200QosStatusIfSchedulerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200QosStatusIfSchedulerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the mapping of (interface, queue) to weight
|
|
values.The mappings given by this table are the 'real' weights in
|
|
percent as used by the hardware"
|
|
::= { me1200QosStatusInterface 2 }
|
|
|
|
me1200QosStatusIfSchedulerEntry OBJECT-TYPE
|
|
SYNTAX ME1200QosStatusIfSchedulerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row contains the scheduler status for a specific queue."
|
|
INDEX { me1200QosStatusIfSchedulerIfIndex, me1200QosStatusIfSchedulerQueue }
|
|
::= { me1200QosStatusIfSchedulerTable 1 }
|
|
|
|
ME1200QosStatusIfSchedulerEntry ::= SEQUENCE {
|
|
me1200QosStatusIfSchedulerIfIndex ME1200InterfaceIndex,
|
|
me1200QosStatusIfSchedulerQueue Integer32,
|
|
me1200QosStatusIfSchedulerWeight ME1200Percent
|
|
}
|
|
|
|
me1200QosStatusIfSchedulerIfIndex OBJECT-TYPE
|
|
SYNTAX ME1200InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical interface index."
|
|
::= { me1200QosStatusIfSchedulerEntry 1 }
|
|
|
|
me1200QosStatusIfSchedulerQueue OBJECT-TYPE
|
|
SYNTAX Integer32 (0..7)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Queue index."
|
|
::= { me1200QosStatusIfSchedulerEntry 2 }
|
|
|
|
me1200QosStatusIfSchedulerWeight OBJECT-TYPE
|
|
SYNTAX ME1200Percent
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The weight for this queue. Valid range is 1-100."
|
|
::= { me1200QosStatusIfSchedulerEntry 3 }
|
|
|
|
me1200QosControl OBJECT IDENTIFIER
|
|
::= { me1200QosMIBObjects 4 }
|
|
|
|
me1200QosControlGlobals OBJECT IDENTIFIER
|
|
::= { me1200QosControl 1 }
|
|
|
|
me1200QosControlGlobalsConflictResolve OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set to true to resolve resource conflicts.
|
|
|
|
If different components, such as ACEs, ECEs, VCEs, QCEs, competes for
|
|
the same resources in the switch, it is possible that some of resources
|
|
needed by one or more QCE are not available. These conflicts, if any,
|
|
are shown in the qosQceStatusTable.
|
|
|
|
To solve these conflicts, you must delete one or more of the competing
|
|
settings and set ConflictResolve to true. The switch will then reapply
|
|
the current QCE configuration."
|
|
::= { me1200QosControlGlobals 1 }
|
|
|
|
me1200QosMIBConformance OBJECT IDENTIFIER
|
|
::= { me1200QosMIB 3 }
|
|
|
|
me1200QosMIBCompliances OBJECT IDENTIFIER
|
|
::= { me1200QosMIBConformance 1 }
|
|
|
|
me1200QosMIBGroups OBJECT IDENTIFIER
|
|
::= { me1200QosMIBConformance 2 }
|
|
|
|
me1200QosStormPolicerUnicastInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200QosStormPolicerUnicastEnable,
|
|
me1200QosStormPolicerUnicastRate }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200QosMIBGroups 1 }
|
|
|
|
me1200QosStormPolicerMulticastInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200QosStormPolicerMulticastEnable,
|
|
me1200QosStormPolicerMulticastRate }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200QosMIBGroups 2 }
|
|
|
|
me1200QosStormPolicerBroadcastInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200QosStormPolicerBroadcastEnable,
|
|
me1200QosStormPolicerBroadcastRate }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200QosMIBGroups 3 }
|
|
|
|
me1200QosWredTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200QosWredEnable, me1200QosWredMinimumFillLevel, me1200QosWredMaximum,
|
|
me1200QosWredMaxSelector }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200QosMIBGroups 4 }
|
|
|
|
me1200QosDscpTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200QosDscpTrust, me1200QosDscpCos, me1200QosDscpDpl,
|
|
me1200QosDscpIngressTranslation, me1200QosDscpClassify,
|
|
me1200QosDscpEgressTranslation, me1200QosDscpEgressTranslationDp1 }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200QosMIBGroups 5 }
|
|
|
|
me1200QosCosToDscpTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200QosCosToDscpDscp, me1200QosCosToDscpDscpDp1 }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200QosMIBGroups 6 }
|
|
|
|
me1200QosQceTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200QosQceNextQceId, me1200QosQcePortList, me1200QosQceDestMacType,
|
|
me1200QosQceDestMac, me1200QosQceDestMacMask, me1200QosQceSrcMac,
|
|
me1200QosQceSrcMacMask, me1200QosQceVlanTagType, me1200QosQceVlanIdOp,
|
|
me1200QosQceVlanId, me1200QosQceVlanIdRange, me1200QosQcePcp, me1200QosQceDei,
|
|
me1200QosQceInnerVlanTagType, me1200QosQceInnerVlanIdOp,
|
|
me1200QosQceInnerVlanId, me1200QosQceInnerVlanIdRange,
|
|
me1200QosQceInnerPcp, me1200QosQceInnerDei, me1200QosQceFrameType,
|
|
me1200QosQceEtype, me1200QosQceLlcDsap, me1200QosQceLlcDsapMask,
|
|
me1200QosQceLlcSsap, me1200QosQceLlcSsapMask, me1200QosQceLlcControl,
|
|
me1200QosQceLlcControlMask, me1200QosQceSnapPid, me1200QosQceSnapPidMask,
|
|
me1200QosQceIpv4Fragment, me1200QosQceIpv4DscpOp, me1200QosQceIpv4Dscp,
|
|
me1200QosQceIpv4DscpRange, me1200QosQceIpv4Protocol,
|
|
me1200QosQceIpv4ProtocolMask, me1200QosQceIpv4SrcIp,
|
|
me1200QosQceIpv4SrcIpMask, me1200QosQceIpv4DestIp,
|
|
me1200QosQceIpv4DestIpMask, me1200QosQceIpv4SrcPortOp,
|
|
me1200QosQceIpv4SrcPort, me1200QosQceIpv4SrcPortRange,
|
|
me1200QosQceIpv4DestPortOp, me1200QosQceIpv4DestPort,
|
|
me1200QosQceIpv4DestPortRange, me1200QosQceIpv6DscpOp,
|
|
me1200QosQceIpv6Dscp, me1200QosQceIpv6DscpRange,
|
|
me1200QosQceIpv6Protocol, me1200QosQceIpv6ProtocolMask,
|
|
me1200QosQceIpv6SrcIp, me1200QosQceIpv6SrcIpMask, me1200QosQceIpv6DestIp,
|
|
me1200QosQceIpv6DestIpMask, me1200QosQceIpv6SrcPortOp,
|
|
me1200QosQceIpv6SrcPort, me1200QosQceIpv6SrcPortRange,
|
|
me1200QosQceIpv6DestPortOp, me1200QosQceIpv6DestPort,
|
|
me1200QosQceIpv6DestPortRange, me1200QosQceActionCosEnable,
|
|
me1200QosQceActionCos, me1200QosQceActionDplEnable,
|
|
me1200QosQceActionDpl, me1200QosQceActionDscpEnable,
|
|
me1200QosQceActionDscp, me1200QosQceActionPcpDeiEnable,
|
|
me1200QosQceActionPcp, me1200QosQceActionDei,
|
|
me1200QosQceActionPolicyEnable, me1200QosQceActionPolicy,
|
|
me1200QosQceAction }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200QosMIBGroups 7 }
|
|
|
|
me1200QosQceTableRowEditorInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200QosQceTableRowEditorQceId,
|
|
me1200QosQceTableRowEditorNextQceId,
|
|
me1200QosQceTableRowEditorPortList,
|
|
me1200QosQceTableRowEditorDestMacType,
|
|
me1200QosQceTableRowEditorDestMac,
|
|
me1200QosQceTableRowEditorDestMacMask,
|
|
me1200QosQceTableRowEditorSrcMac,
|
|
me1200QosQceTableRowEditorSrcMacMask,
|
|
me1200QosQceTableRowEditorVlanTagType,
|
|
me1200QosQceTableRowEditorVlanIdOp,
|
|
me1200QosQceTableRowEditorVlanId,
|
|
me1200QosQceTableRowEditorVlanIdRange,
|
|
me1200QosQceTableRowEditorPcp, me1200QosQceTableRowEditorDei,
|
|
me1200QosQceTableRowEditorInnerVlanTagType,
|
|
me1200QosQceTableRowEditorInnerVlanIdOp,
|
|
me1200QosQceTableRowEditorInnerVlanId,
|
|
me1200QosQceTableRowEditorInnerVlanIdRange,
|
|
me1200QosQceTableRowEditorInnerPcp,
|
|
me1200QosQceTableRowEditorInnerDei,
|
|
me1200QosQceTableRowEditorFrameType,
|
|
me1200QosQceTableRowEditorEtype, me1200QosQceTableRowEditorLlcDsap,
|
|
me1200QosQceTableRowEditorLlcDsapMask,
|
|
me1200QosQceTableRowEditorLlcSsap,
|
|
me1200QosQceTableRowEditorLlcSsapMask,
|
|
me1200QosQceTableRowEditorLlcControl,
|
|
me1200QosQceTableRowEditorLlcControlMask,
|
|
me1200QosQceTableRowEditorSnapPid,
|
|
me1200QosQceTableRowEditorSnapPidMask,
|
|
me1200QosQceTableRowEditorIpv4Fragment,
|
|
me1200QosQceTableRowEditorIpv4DscpOp,
|
|
me1200QosQceTableRowEditorIpv4Dscp,
|
|
me1200QosQceTableRowEditorIpv4DscpRange,
|
|
me1200QosQceTableRowEditorIpv4Protocol,
|
|
me1200QosQceTableRowEditorIpv4ProtocolMask,
|
|
me1200QosQceTableRowEditorIpv4SrcIp,
|
|
me1200QosQceTableRowEditorIpv4SrcIpMask,
|
|
me1200QosQceTableRowEditorIpv4DestIp,
|
|
me1200QosQceTableRowEditorIpv4DestIpMask,
|
|
me1200QosQceTableRowEditorIpv4SrcPortOp,
|
|
me1200QosQceTableRowEditorIpv4SrcPort,
|
|
me1200QosQceTableRowEditorIpv4SrcPortRange,
|
|
me1200QosQceTableRowEditorIpv4DestPortOp,
|
|
me1200QosQceTableRowEditorIpv4DestPort,
|
|
me1200QosQceTableRowEditorIpv4DestPortRange,
|
|
me1200QosQceTableRowEditorIpv6DscpOp,
|
|
me1200QosQceTableRowEditorIpv6Dscp,
|
|
me1200QosQceTableRowEditorIpv6DscpRange,
|
|
me1200QosQceTableRowEditorIpv6Protocol,
|
|
me1200QosQceTableRowEditorIpv6ProtocolMask,
|
|
me1200QosQceTableRowEditorIpv6SrcIp,
|
|
me1200QosQceTableRowEditorIpv6SrcIpMask,
|
|
me1200QosQceTableRowEditorIpv6DestIp,
|
|
me1200QosQceTableRowEditorIpv6DestIpMask,
|
|
me1200QosQceTableRowEditorIpv6SrcPortOp,
|
|
me1200QosQceTableRowEditorIpv6SrcPort,
|
|
me1200QosQceTableRowEditorIpv6SrcPortRange,
|
|
me1200QosQceTableRowEditorIpv6DestPortOp,
|
|
me1200QosQceTableRowEditorIpv6DestPort,
|
|
me1200QosQceTableRowEditorIpv6DestPortRange,
|
|
me1200QosQceTableRowEditorActionCosEnable,
|
|
me1200QosQceTableRowEditorActionCos,
|
|
me1200QosQceTableRowEditorActionDplEnable,
|
|
me1200QosQceTableRowEditorActionDpl,
|
|
me1200QosQceTableRowEditorActionDscpEnable,
|
|
me1200QosQceTableRowEditorActionDscp,
|
|
me1200QosQceTableRowEditorActionPcpDeiEnable,
|
|
me1200QosQceTableRowEditorActionPcp,
|
|
me1200QosQceTableRowEditorActionDei,
|
|
me1200QosQceTableRowEditorActionPolicyEnable,
|
|
me1200QosQceTableRowEditorActionPolicy,
|
|
me1200QosQceTableRowEditorAction }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200QosMIBGroups 8 }
|
|
|
|
me1200QosQcePrecedenceTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200QosQcePrecedenceQceId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200QosMIBGroups 9 }
|
|
|
|
me1200QosIfConfigTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200QosIfConfigCos, me1200QosIfConfigDpl, me1200QosIfConfigPcp,
|
|
me1200QosIfConfigDei, me1200QosIfConfigTrustTag,
|
|
me1200QosIfConfigTrustDscp, me1200QosIfConfigDwrrCount,
|
|
me1200QosIfConfigTagRemarkingMode, me1200QosIfConfigTagPcp,
|
|
me1200QosIfConfigTagDei, me1200QosIfConfigDscpTranslate,
|
|
me1200QosIfConfigDscpClassify, me1200QosIfConfigDscpRemark,
|
|
me1200QosIfConfigQceAddressMode, me1200QosIfConfigQceKeyType }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200QosMIBGroups 10 }
|
|
|
|
me1200QosIfTagToCosTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200QosIfTagToCosCos, me1200QosIfTagToCosDpl }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200QosMIBGroups 11 }
|
|
|
|
me1200QosIfCosToTagTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200QosIfCosToTagPcp, me1200QosIfCosToTagDei }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200QosMIBGroups 12 }
|
|
|
|
me1200QosIfPolicerTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200QosIfPolicerEnable, me1200QosIfPolicerFrameRate,
|
|
me1200QosIfPolicerFlowControl, me1200QosIfPolicerCir }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200QosMIBGroups 13 }
|
|
|
|
me1200QosIfQueuePolicerTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200QosIfQueuePolicerEnable, me1200QosIfQueuePolicerCir }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200QosMIBGroups 14 }
|
|
|
|
me1200QosIfShaperTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200QosIfShaperEnable, me1200QosIfShaperCir }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200QosMIBGroups 15 }
|
|
|
|
me1200QosIfQueueShaperTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200QosIfQueueShaperEnable, me1200QosIfQueueShaperExcess,
|
|
me1200QosIfQueueShaperCir }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200QosMIBGroups 16 }
|
|
|
|
me1200QosIfSchedulerTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200QosIfSchedulerWeight }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200QosMIBGroups 17 }
|
|
|
|
me1200QosStatusQceTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200QosStatusQceUserId, me1200QosStatusQceQceId,
|
|
me1200QosStatusQceConflict }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200QosMIBGroups 18 }
|
|
|
|
me1200QosStatusIfTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200QosStatusIfCos }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200QosMIBGroups 19 }
|
|
|
|
me1200QosStatusIfSchedulerTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200QosStatusIfSchedulerWeight }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200QosMIBGroups 20 }
|
|
|
|
me1200QosControlGlobalsInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200QosControlGlobalsConflictResolve }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200QosMIBGroups 21 }
|
|
|
|
me1200QosMIBCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for the implementation."
|
|
|
|
MODULE -- this module
|
|
|
|
MANDATORY-GROUPS { me1200QosStormPolicerUnicastInfoGroup,
|
|
me1200QosStormPolicerMulticastInfoGroup,
|
|
me1200QosStormPolicerBroadcastInfoGroup,
|
|
me1200QosWredTableInfoGroup, me1200QosDscpTableInfoGroup,
|
|
me1200QosCosToDscpTableInfoGroup, me1200QosQceTableInfoGroup,
|
|
me1200QosQceTableRowEditorInfoGroup,
|
|
me1200QosQcePrecedenceTableInfoGroup,
|
|
me1200QosIfConfigTableInfoGroup, me1200QosIfTagToCosTableInfoGroup,
|
|
me1200QosIfCosToTagTableInfoGroup,
|
|
me1200QosIfPolicerTableInfoGroup,
|
|
me1200QosIfQueuePolicerTableInfoGroup,
|
|
me1200QosIfShaperTableInfoGroup,
|
|
me1200QosIfQueueShaperTableInfoGroup,
|
|
me1200QosIfSchedulerTableInfoGroup,
|
|
me1200QosStatusQceTableInfoGroup, me1200QosStatusIfTableInfoGroup,
|
|
me1200QosStatusIfSchedulerTableInfoGroup,
|
|
me1200QosControlGlobalsInfoGroup }
|
|
|
|
::= { me1200QosMIBCompliances 1 }
|
|
|
|
END
|