Observium_CE/mibs/cisco/ME1200-ARP-INSPECTION-MIB

515 lines
18 KiB
Plaintext

-- *****************************************************************
-- ARP-INSPECTION-MIB: ME1200 Private MIB
--
--
-- ****************************************************************
ME1200-ARP-INSPECTION-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
MODULE-IDENTITY, OBJECT-TYPE
FROM SNMPv2-SMI
TEXTUAL-CONVENTION
FROM SNMPv2-TC
me1200SwitchMgmt
FROM CISCOME1200-MIB
ME1200InterfaceIndex FROM ME1200-TC
ME1200RowEditorState FROM ME1200-TC
Integer32 FROM SNMPv2-SMI
IpAddress FROM SNMPv2-SMI
MacAddress FROM SNMPv2-TC
TruthValue FROM SNMPv2-TC
;
me1200ArpInspectionMib MODULE-IDENTITY
LAST-UPDATED "201403280000Z"
ORGANIZATION
"Cisco Systems, Inc"
CONTACT-INFO
"Cisco Systems, Inc
Customer Service
Postal: 170 W Tasman Drive
San Jose, CA 95134
USA
Tel: +1 800 553-NETS
E-mail: cs-me1200@cisco.com"
DESCRIPTION
"This is a private version of the ARP Inspection MIB"
REVISION "201403280000Z"
DESCRIPTION
"Change VLAN ID range specification from (0..4094) to (1..4095)"
REVISION "201403110000Z"
DESCRIPTION
"Definition of type InterfaceIndex changed from Unsigned32 to Integer32
as it is used as index in some tables"
REVISION "201402180000Z"
DESCRIPTION
"Do no use Unsigned32 for indexes"
REVISION "201401290000Z"
DESCRIPTION
"Locate all objects under ciscoME1200MIB"
REVISION "201310250000Z"
DESCRIPTION
"Initial version"
::= { me1200SwitchMgmt 63 }
ME1200ArpInspectionLogType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This enumeration indicates the ARP entry log type."
SYNTAX INTEGER { none(0), deny(1), permit(2), all(3) }
ME1200ArpInspectionRegisterStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This enumeration indicates the ARP entry registration type."
SYNTAX INTEGER { static(0), dynamic(1) }
me1200ArpInspectionMIBObjects OBJECT IDENTIFIER
::= { me1200ArpInspectionMib 1 }
me1200ArpInspectionConfig OBJECT IDENTIFIER
::= { me1200ArpInspectionMIBObjects 2 }
me1200ArpInspectionGlobals OBJECT IDENTIFIER
::= { me1200ArpInspectionConfig 1 }
me1200ArpInspectionGlobalsAdminState OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable the ARP Inspection global functionality."
::= { me1200ArpInspectionGlobals 1 }
me1200ArpInspectionPortConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF ME1200ArpInspectionPortConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is a table for managing ARP Inspection per port basis"
::= { me1200ArpInspectionConfig 2 }
me1200ArpInspectionPortConfigEntry OBJECT-TYPE
SYNTAX ME1200ArpInspectionPortConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each port has a set of parameters"
INDEX { me1200ArpInspectionPortConfigIfIndex }
::= { me1200ArpInspectionPortConfigTable 1 }
ME1200ArpInspectionPortConfigEntry ::= SEQUENCE {
me1200ArpInspectionPortConfigIfIndex ME1200InterfaceIndex,
me1200ArpInspectionPortConfigMode TruthValue,
me1200ArpInspectionPortConfigCheckVlan TruthValue,
me1200ArpInspectionPortConfigLogType ME1200ArpInspectionLogType
}
me1200ArpInspectionPortConfigIfIndex OBJECT-TYPE
SYNTAX ME1200InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Logical interface number of the physical port."
::= { me1200ArpInspectionPortConfigEntry 1 }
me1200ArpInspectionPortConfigMode OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable the ARP Inspection per-port functionality. Only when
both Global Mode and Port Mode on a given port are enabled, ARP
Inspection is enabled on this given port."
::= { me1200ArpInspectionPortConfigEntry 2 }
me1200ArpInspectionPortConfigCheckVlan OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable the ARP Inspection VLAN checking will log the inspected entries
by referring to arpInspectionVlanConfigTable setting. Disable the ARP
Inspection VLAN checking will log the inspected entries by referring to
arpInspectionPortConfigTable setting."
::= { me1200ArpInspectionPortConfigEntry 3 }
me1200ArpInspectionPortConfigLogType OBJECT-TYPE
SYNTAX ME1200ArpInspectionLogType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The capability to log the inspected entries per port basis. none(0)
will log nothing. deny(1) will log the denied entries. permit(2) will
log the permitted entries. all(3) will log all kinds of inspected
entries."
::= { me1200ArpInspectionPortConfigEntry 4 }
me1200ArpInspectionVlanConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF ME1200ArpInspectionVlanConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is a table for managing ARP Inspection per VLAN basis"
::= { me1200ArpInspectionConfig 3 }
me1200ArpInspectionVlanConfigEntry OBJECT-TYPE
SYNTAX ME1200ArpInspectionVlanConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each VLAN has a set of parameters"
INDEX { me1200ArpInspectionVlanConfigVlanId }
::= { me1200ArpInspectionVlanConfigTable 1 }
ME1200ArpInspectionVlanConfigEntry ::= SEQUENCE {
me1200ArpInspectionVlanConfigVlanId Integer32,
me1200ArpInspectionVlanConfigLogType ME1200ArpInspectionLogType,
me1200ArpInspectionVlanConfigAction ME1200RowEditorState
}
me1200ArpInspectionVlanConfigVlanId OBJECT-TYPE
SYNTAX Integer32 (1..4095)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VID of the VLAN."
::= { me1200ArpInspectionVlanConfigEntry 1 }
me1200ArpInspectionVlanConfigLogType OBJECT-TYPE
SYNTAX ME1200ArpInspectionLogType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The capability to log the inspected entries per VLAN basis. none(0)
will log nothing. deny(1) will log the denied entries. permit(2) will
log the permitted entries. all(3) will log all kinds of inspected
entries."
::= { me1200ArpInspectionVlanConfigEntry 2 }
me1200ArpInspectionVlanConfigAction OBJECT-TYPE
SYNTAX ME1200RowEditorState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Action"
::= { me1200ArpInspectionVlanConfigEntry 100 }
me1200ArpInspectionVlanConfigTableRowEditor OBJECT IDENTIFIER
::= { me1200ArpInspectionConfig 4 }
me1200ArpInspectionVlanConfigTableRowEditorVlanId OBJECT-TYPE
SYNTAX Integer32 (1..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The VID of the VLAN."
::= { me1200ArpInspectionVlanConfigTableRowEditor 1 }
me1200ArpInspectionVlanConfigTableRowEditorLogType OBJECT-TYPE
SYNTAX ME1200ArpInspectionLogType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The capability to log the inspected entries per VLAN basis. none(0)
will log nothing. deny(1) will log the denied entries. permit(2) will
log the permitted entries. all(3) will log all kinds of inspected
entries."
::= { me1200ArpInspectionVlanConfigTableRowEditor 2 }
me1200ArpInspectionVlanConfigTableRowEditorAction OBJECT-TYPE
SYNTAX ME1200RowEditorState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Action"
::= { me1200ArpInspectionVlanConfigTableRowEditor 100 }
me1200ArpInspectionStaticConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF ME1200ArpInspectionStaticConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is a table for managing static ARP Inspection configuration"
::= { me1200ArpInspectionConfig 5 }
me1200ArpInspectionStaticConfigEntry OBJECT-TYPE
SYNTAX ME1200ArpInspectionStaticConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry has a set of parameters"
INDEX { me1200ArpInspectionStaticConfigIfIndex, me1200ArpInspectionStaticConfigVlanId, me1200ArpInspectionStaticConfigMacAddress, me1200ArpInspectionStaticConfigIpAddress }
::= { me1200ArpInspectionStaticConfigTable 1 }
ME1200ArpInspectionStaticConfigEntry ::= SEQUENCE {
me1200ArpInspectionStaticConfigIfIndex ME1200InterfaceIndex,
me1200ArpInspectionStaticConfigVlanId Integer32,
me1200ArpInspectionStaticConfigMacAddress MacAddress,
me1200ArpInspectionStaticConfigIpAddress IpAddress,
me1200ArpInspectionStaticConfigAction ME1200RowEditorState
}
me1200ArpInspectionStaticConfigIfIndex OBJECT-TYPE
SYNTAX ME1200InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Logical interface number of the physical port."
::= { me1200ArpInspectionStaticConfigEntry 1 }
me1200ArpInspectionStaticConfigVlanId OBJECT-TYPE
SYNTAX Integer32 (1..4095)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VID of the VLAN."
::= { me1200ArpInspectionStaticConfigEntry 2 }
me1200ArpInspectionStaticConfigMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Assigned MAC address."
::= { me1200ArpInspectionStaticConfigEntry 3 }
me1200ArpInspectionStaticConfigIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Assigned IPv4 address."
::= { me1200ArpInspectionStaticConfigEntry 4 }
me1200ArpInspectionStaticConfigAction OBJECT-TYPE
SYNTAX ME1200RowEditorState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Action"
::= { me1200ArpInspectionStaticConfigEntry 100 }
me1200ArpInspectionStaticConfigTableRowEditor OBJECT IDENTIFIER
::= { me1200ArpInspectionConfig 6 }
me1200ArpInspectionStaticConfigTableRowEditorIfIndex OBJECT-TYPE
SYNTAX ME1200InterfaceIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Logical interface number of the physical port."
::= { me1200ArpInspectionStaticConfigTableRowEditor 1 }
me1200ArpInspectionStaticConfigTableRowEditorVlanId OBJECT-TYPE
SYNTAX Integer32 (1..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The VID of the VLAN."
::= { me1200ArpInspectionStaticConfigTableRowEditor 2 }
me1200ArpInspectionStaticConfigTableRowEditorMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Assigned MAC address."
::= { me1200ArpInspectionStaticConfigTableRowEditor 3 }
me1200ArpInspectionStaticConfigTableRowEditorIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Assigned IPv4 address."
::= { me1200ArpInspectionStaticConfigTableRowEditor 4 }
me1200ArpInspectionStaticConfigTableRowEditorAction OBJECT-TYPE
SYNTAX ME1200RowEditorState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Action"
::= { me1200ArpInspectionStaticConfigTableRowEditor 100 }
me1200ArpInspectionStatus OBJECT IDENTIFIER
::= { me1200ArpInspectionMIBObjects 3 }
me1200ArpInspectionDynamicAddressTable OBJECT-TYPE
SYNTAX SEQUENCE OF ME1200ArpInspectionDynamicAddressEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is a table for displaying all ARP Inspection entries"
::= { me1200ArpInspectionStatus 1 }
me1200ArpInspectionDynamicAddressEntry OBJECT-TYPE
SYNTAX ME1200ArpInspectionDynamicAddressEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry has a set of parameters"
INDEX { me1200ArpInspectionDynamicAddressIfIndex, me1200ArpInspectionDynamicAddressVlanId, me1200ArpInspectionDynamicAddressMacAddress, me1200ArpInspectionDynamicAddressIpAddress }
::= { me1200ArpInspectionDynamicAddressTable 1 }
ME1200ArpInspectionDynamicAddressEntry ::= SEQUENCE {
me1200ArpInspectionDynamicAddressIfIndex ME1200InterfaceIndex,
me1200ArpInspectionDynamicAddressVlanId Integer32,
me1200ArpInspectionDynamicAddressMacAddress MacAddress,
me1200ArpInspectionDynamicAddressIpAddress IpAddress,
me1200ArpInspectionDynamicAddressType ME1200ArpInspectionRegisterStatus
}
me1200ArpInspectionDynamicAddressIfIndex OBJECT-TYPE
SYNTAX ME1200InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Logical interface number of the physical port."
::= { me1200ArpInspectionDynamicAddressEntry 1 }
me1200ArpInspectionDynamicAddressVlanId OBJECT-TYPE
SYNTAX Integer32 (1..4095)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VID of the VLAN."
::= { me1200ArpInspectionDynamicAddressEntry 2 }
me1200ArpInspectionDynamicAddressMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Assigned MAC address."
::= { me1200ArpInspectionDynamicAddressEntry 3 }
me1200ArpInspectionDynamicAddressIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Assigned IPv4 address."
::= { me1200ArpInspectionDynamicAddressEntry 4 }
me1200ArpInspectionDynamicAddressType OBJECT-TYPE
SYNTAX ME1200ArpInspectionRegisterStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Either static(0) or dynamic(1) for the specific ARP entry."
::= { me1200ArpInspectionDynamicAddressEntry 5 }
me1200ArpInspectionControl OBJECT IDENTIFIER
::= { me1200ArpInspectionMIBObjects 4 }
me1200ArpInspectionControlGlobals OBJECT IDENTIFIER
::= { me1200ArpInspectionControl 1 }
me1200ArpInspectionControlGlobalsTranslateDynamicToStatic OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"To trigger the control action (only) when TRUE."
::= { me1200ArpInspectionControlGlobals 1 }
me1200ArpInspectionMIBConformance OBJECT IDENTIFIER
::= { me1200ArpInspectionMib 2 }
me1200ArpInspectionMIBCompliances OBJECT IDENTIFIER
::= { me1200ArpInspectionMIBConformance 1 }
me1200ArpInspectionMIBGroups OBJECT IDENTIFIER
::= { me1200ArpInspectionMIBConformance 2 }
me1200ArpInspectionGlobalsInfoGroup OBJECT-GROUP
OBJECTS { me1200ArpInspectionGlobalsAdminState }
STATUS current
DESCRIPTION
"A collection of objects suitable for bulk operations."
::= { me1200ArpInspectionMIBGroups 1 }
me1200ArpInspectionPortConfigTableInfoGroup OBJECT-GROUP
OBJECTS { me1200ArpInspectionPortConfigMode,
me1200ArpInspectionPortConfigCheckVlan,
me1200ArpInspectionPortConfigLogType }
STATUS current
DESCRIPTION
"A collection of objects suitable for bulk operations."
::= { me1200ArpInspectionMIBGroups 2 }
me1200ArpInspectionVlanConfigTableInfoGroup OBJECT-GROUP
OBJECTS { me1200ArpInspectionVlanConfigLogType,
me1200ArpInspectionVlanConfigAction }
STATUS current
DESCRIPTION
"A collection of objects suitable for bulk operations."
::= { me1200ArpInspectionMIBGroups 3 }
me1200ArpInspectionVlanConfigTableRowEditorInfoGroup OBJECT-GROUP
OBJECTS { me1200ArpInspectionVlanConfigTableRowEditorVlanId,
me1200ArpInspectionVlanConfigTableRowEditorLogType,
me1200ArpInspectionVlanConfigTableRowEditorAction }
STATUS current
DESCRIPTION
"A collection of objects suitable for bulk operations."
::= { me1200ArpInspectionMIBGroups 4 }
me1200ArpInspectionStaticConfigTableInfoGroup OBJECT-GROUP
OBJECTS { me1200ArpInspectionStaticConfigAction }
STATUS current
DESCRIPTION
"A collection of objects suitable for bulk operations."
::= { me1200ArpInspectionMIBGroups 5 }
me1200ArpInspectionStaticConfigTableRowEditorInfoGroup OBJECT-GROUP
OBJECTS { me1200ArpInspectionStaticConfigTableRowEditorIfIndex,
me1200ArpInspectionStaticConfigTableRowEditorVlanId,
me1200ArpInspectionStaticConfigTableRowEditorMacAddress,
me1200ArpInspectionStaticConfigTableRowEditorIpAddress,
me1200ArpInspectionStaticConfigTableRowEditorAction }
STATUS current
DESCRIPTION
"A collection of objects suitable for bulk operations."
::= { me1200ArpInspectionMIBGroups 6 }
me1200ArpInspectionDynamicAddressTableInfoGroup OBJECT-GROUP
OBJECTS { me1200ArpInspectionDynamicAddressType }
STATUS current
DESCRIPTION
"A collection of objects suitable for bulk operations."
::= { me1200ArpInspectionMIBGroups 7 }
me1200ArpInspectionControlGlobalsInfoGroup OBJECT-GROUP
OBJECTS { me1200ArpInspectionControlGlobalsTranslateDynamicToStatic }
STATUS current
DESCRIPTION
"A collection of objects suitable for bulk operations."
::= { me1200ArpInspectionMIBGroups 8 }
me1200ArpInspectionMibCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for the implementation."
MODULE -- this module
MANDATORY-GROUPS { me1200ArpInspectionGlobalsInfoGroup,
me1200ArpInspectionPortConfigTableInfoGroup,
me1200ArpInspectionVlanConfigTableInfoGroup,
me1200ArpInspectionVlanConfigTableRowEditorInfoGroup,
me1200ArpInspectionStaticConfigTableInfoGroup,
me1200ArpInspectionStaticConfigTableRowEditorInfoGroup,
me1200ArpInspectionDynamicAddressTableInfoGroup,
me1200ArpInspectionControlGlobalsInfoGroup }
::= { me1200ArpInspectionMIBCompliances 1 }
END