Observium_CE/mibs/cisco/CISCO-IETF-MPLS-TE-EXT-STD-03-MIB

751 lines
25 KiB
Plaintext

CISCO-IETF-MPLS-TE-EXT-STD-03-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Unsigned32,
Counter32,
Counter64,
Gauge32,
zeroDotZero,
NOTIFICATION-TYPE
FROM SNMPv2-SMI
MODULE-COMPLIANCE,
OBJECT-GROUP,
NOTIFICATION-GROUP
FROM SNMPv2-CONF
TruthValue,
RowStatus,
RowPointer,
StorageType
FROM SNMPv2-TC
mplsStdMIB,
MplsTunnelIndex,
MplsTunnelInstanceIndex
FROM MPLS-TC-STD-MIB
mplsTunnelIndex,
mplsTunnelInstance,
mplsTunnelIngressLSRId,
mplsTunnelEgressLSRId
FROM MPLS-TE-STD-MIB
CMplsLocalId,
CMplsGlobalId,
CMplsNodeId,
CMplsIccId
FROM CISCO-MPLS-TC-EXT-STD-MIB
ciscoExperiment
FROM CISCO-SMI;
cmplsTeExtStdMIB MODULE-IDENTITY
LAST-UPDATED "201206060000Z"
ORGANIZATION "Multiprotocol Label Switching (MPLS) Working Group"
CONTACT-INFO
"Venkatesan Mahalingam
Dell Inc,
350 Holger way, San Jose, CA, USA
Email: venkat.mahalingams@gmail.com
Kannan KV Sampath
Aricent,
India
Email: Kannan.Sampath@aricent.com
Sam Aldrin
Huawei Technologies
2330 Central Express Way,
Santa Clara, CA 95051, USA
Email: aldrin.ietf@gmail.com
Thomas D. Nadeau
Juniper Networks
10 Technology Park Drive, Westford, MA 01886
Email: tnadeau@juniper.net"
DESCRIPTION
"Copyright (c) 2012 IETF Trust and the persons identified
as the document authors. All rights reserved.
This MIB module contains generic object definitions for
MPLS Traffic Engineering in transport networks.This module is a
cisco-ized version of the IETF draft:
draft-ietf-mpls-tp-te-mib-03"
REVISION "201204080000Z"
DESCRIPTION
"MPLS TE mib objects extension"
::= { ciscoExperiment 146 }
-- Top level components of this MIB module.
--
-- traps
cmplsTeExtNotifications OBJECT IDENTIFIER
::= { cmplsTeExtStdMIB 0 }
-- tables, scalars
cmplsTeExtObjects OBJECT IDENTIFIER
::= { cmplsTeExtStdMIB 1 }
-- conformance
cmplsTeExtConformance OBJECT IDENTIFIER
::= { cmplsTeExtStdMIB 2 }
-- Start of MPLS Transport Profile Node configuration table
cmplsNodeConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF CmplsNodeConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table allows the administrator to map a node or
LSR Identifier (IP compatible [Global_Node_ID] or ICC)
with a local identifier.
This table is created to reuse the existing
mplsTunnelTable for MPLS based transport network
tunnels also.
Since the MPLS tunnel's Ingress/Egress LSR identifiers'
size (Unsigned32) value is not compatible for
MPLS-TP tunnel i.e. Global_Node_Id of size 8 bytes and
ICC of size 6 bytes, there exists a need to map the
Global_Node_ID or ICC with the local identifier of size
4 bytes (Unsigned32) value in order
to index (Ingress/Egress LSR identifier)
the existing mplsTunnelTable."
::= { cmplsTeExtObjects 1 }
cmplsNodeConfigEntry OBJECT-TYPE
SYNTAX CmplsNodeConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents a mapping
identification for the operator or service provider
with node or LSR.
As per [RFC6370], this mapping is
represented as Global_Node_ID or ICC.
Note: Each entry in this table should have a unique
Global_ID and Node_ID combination."
INDEX { cmplsNodeConfigLocalId }
::= { cmplsNodeConfigTable 1 }
CmplsNodeConfigEntry ::= SEQUENCE {
cmplsNodeConfigLocalId CMplsLocalId,
cmplsNodeConfigGlobalId CMplsGlobalId,
cmplsNodeConfigNodeId CMplsNodeId,
cmplsNodeConfigIccId CMplsIccId,
cmplsNodeConfigRowStatus RowStatus,
cmplsNodeConfigStorageType StorageType
}
cmplsNodeConfigLocalId OBJECT-TYPE
SYNTAX CMplsLocalId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object allows the administrator to assign a unique
local identifier to map Global_Node_ID or ICC."
::= { cmplsNodeConfigEntry 1 }
cmplsNodeConfigGlobalId OBJECT-TYPE
SYNTAX CMplsGlobalId
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Global Operator Identifier.
This object value should be zero when
mplsNodeConfigIccId is configured with non-null value."
REFERENCE "MPLS-TP Identifiers [RFC6370]."
::= { cmplsNodeConfigEntry 2 }
cmplsNodeConfigNodeId OBJECT-TYPE
SYNTAX CMplsNodeId
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Node_ID within the operator.
This object value should be zero when mplsNodeConfigIccId
is configured with non-null value."
REFERENCE "MPLS-TP Identifiers [RFC6370]."
::= { cmplsNodeConfigEntry 3 }
cmplsNodeConfigIccId OBJECT-TYPE
SYNTAX CMplsIccId
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the operator or service provider to
configure a unique MPLS-TP ITU-T Carrier Code (ICC)
either for Ingress ID or Egress ID.
This object value should be zero when
mplsNodeConfigGlobalId and mplsNodeConfigNodeId are
assigned with non-zero value."
REFERENCE "MPLS-TP Identifiers [RFC6370]."
::= { cmplsNodeConfigEntry 4 }
cmplsNodeConfigRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the administrator to create, modify,
and/or delete a row in this table."
::= { cmplsNodeConfigEntry 5 }
cmplsNodeConfigStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates the storage type for this
object.
Conceptual rows having the value 'permanent'
need not allow write-access to any columnar
objects in the row."
DEFVAL { volatile }
::= { cmplsNodeConfigEntry 6 }
-- End of MPLS Transport Profile Node configuration table
--
-- Start of MPLS Transport Profile Node IP compatible
-- mapping table
cmplsNodeIpMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF CmplsNodeIpMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This read-only table allows the administrator to retrieve
the local identifier for a given Global_Node_ID in an IP
compatible operator environment.
This table MAY be used in on-demand and/or proactive
OAM operations to get the Ingress/Egress LSR identifier
(Local Identifier) from Src-Global_Node_ID
or Dst-Global_Node_ID and the Ingress and Egress LSR
identifiers are used to retrieve the tunnel entry.
This table returns nothing when the associated entry
is not defined in mplsNodeConfigTable."
::= { cmplsTeExtObjects 2 }
cmplsNodeIpMapEntry OBJECT-TYPE
SYNTAX CmplsNodeIpMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents a mapping of
Global_Node_ID with the local identifier.
An entry in this table is created automatically when
the Local identifier is associated with Global_ID and
Node_Id in the mplsNodeConfigTable.
Note: Each entry in this table should have a unique
Global_ID and Node_ID combination."
INDEX {
cmplsNodeIpMapGlobalId,
cmplsNodeIpMapNodeId
}
::= { cmplsNodeIpMapTable 1 }
CmplsNodeIpMapEntry ::= SEQUENCE {
cmplsNodeIpMapGlobalId CMplsGlobalId,
cmplsNodeIpMapNodeId CMplsNodeId,
cmplsNodeIpMapLocalId CMplsLocalId
}
cmplsNodeIpMapGlobalId OBJECT-TYPE
SYNTAX CMplsGlobalId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Global_ID."
::= { cmplsNodeIpMapEntry 1 }
cmplsNodeIpMapNodeId OBJECT-TYPE
SYNTAX CMplsNodeId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Node_ID within the
operator."
::= { cmplsNodeIpMapEntry 2 }
cmplsNodeIpMapLocalId OBJECT-TYPE
SYNTAX CMplsLocalId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an IP compatible local identifier
which is defined in mplsNodeConfigTable."
::= { cmplsNodeIpMapEntry 3 }
-- End MPLS Transport Profile Node IP compatible table
--
-- Start of MPLS Transport Profile Node ICC based table
cmplsNodeIccMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF CmplsNodeIccMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This read-only table allows the administrator to retrieve
the local identifier for a given ICC operator in an ICC
operator environment.
This table MAY be used in on-demand and/or proactive
OAM operations to get the Ingress/Egress LSR
identifier (Local Identifier) from Src-ICC
or Dst-ICC and the Ingress and Egress LSR
identifiers are used to retrieve the tunnel entry.
This table returns nothing when the associated entry
is not defined in mplsNodeConfigTable."
::= { cmplsTeExtObjects 3 }
cmplsNodeIccMapEntry OBJECT-TYPE
SYNTAX CmplsNodeIccMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents a mapping of ICC with
the local identifier.
An entry in this table is created automatically when
the Local identifier is associated with ICC in
the mplsNodeConfigTable."
INDEX { cmplsNodeIccMapIccId }
::= { cmplsNodeIccMapTable 1 }
CmplsNodeIccMapEntry ::= SEQUENCE {
cmplsNodeIccMapIccId CMplsIccId,
cmplsNodeIccMapLocalId CMplsLocalId
}
cmplsNodeIccMapIccId OBJECT-TYPE
SYNTAX CMplsIccId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object allows the operator or service provider to
configure a unique MPLS-TP ITU-T Carrier Code (ICC)
either for Ingress or Egress LSR ID.
The ICC is a string of one to six characters, each
character being either alphabetic (i.e. A-Z) or
numeric (i.e. 0-9) characters. Alphabetic characters
in the ICC should be represented with upper case
letters."
::= { cmplsNodeIccMapEntry 1 }
cmplsNodeIccMapLocalId OBJECT-TYPE
SYNTAX CMplsLocalId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an ICC based local identifier
which is defined in mplsNodeConfigTable."
::= { cmplsNodeIccMapEntry 2 }
-- End MPLS Transport Profile Node ICC based table
--
-- Start of MPLS Tunnel table extension
cmplsTunnelExtTable OBJECT-TYPE
SYNTAX SEQUENCE OF CmplsTunnelExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table represents MPLS-TP specific extensions to
mplsTunnelTable.
As per MPLS-TP Identifiers [RFC6370], LSP_ID for IP based
co-routed bidirectional tunnel,
A1-{Global_ID::Node_ID::Tunnel_Num}::Z9-{Global_ID::
Node_ID::Tunnel_Num}::LSP_Num
LSP_ID for IP based associated bidirectional tunnel,
A1-{Global_ID::Node_ID::Tunnel_Num::LSP_Num}::
Z9-{Global_ID::Node_ID::Tunnel_Num::LSP_Num}
mplsTunnelTable is reused for forming the LSP_ID
as follows,
Source Tunnel_Num is mapped with mplsTunnelIndex,
Source Node_ID is mapped with
mplsTunnelIngressLSRId, Destination Node_ID is
mapped with mplsTunnelEgressLSRId LSP_Num is mapped with
mplsTunnelInstance.
Source Global_Node_ID and/or ICC and Destination
Global_Node_ID and/or ICC are maintained in the
mplsNodeConfigTable and mplsNodeConfigLocalId is
used to create an entry in mplsTunnelTable."
REFERENCE "MPLS-TP Identifiers [RFC6370]."
::= { cmplsTeExtObjects 4 }
cmplsTunnelExtEntry OBJECT-TYPE
SYNTAX CmplsTunnelExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents MPLS-TP
specific additional tunnel configurations."
INDEX {
mplsTunnelIndex,
mplsTunnelInstance,
mplsTunnelIngressLSRId,
mplsTunnelEgressLSRId
}
::= { cmplsTunnelExtTable 1 }
CmplsTunnelExtEntry ::= SEQUENCE {
cmplsTunnelOppositeDirPtr RowPointer,
cmplsTunnelExtOppositeDirTnlValid TruthValue,
cmplsTunnelExtDestTnlIndex MplsTunnelIndex,
cmplsTunnelExtDestTnlLspIndex MplsTunnelInstanceIndex,
cmplsTunnelExtDestTnlValid TruthValue
}
cmplsTunnelOppositeDirPtr OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is applicable only for the bidirectional
tunnel that has the forward and reverse LSPs in the
same tunnel or in the different tunnels.
This object holds the opposite direction tunnel entry
if the bidirectional tunnel is setup by configuring two
tunnel entries in mplsTunnelTable.
The value of zeroDotZero indicates single tunnel entry
is used for bidirectional tunnel setup."
DEFVAL { zeroDotZero }
::= { cmplsTunnelExtEntry 1 }
cmplsTunnelExtOppositeDirTnlValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Denotes whether or not this tunnel uses
mplsTunnelOppositeDirPtr for identifying the opposite
direction tunnel information. Note that if this variable
is set to true then the mplsTunnelOppositeDirPtr should
point to the first accessible row of the opposite
direction tunnel."
DEFVAL { false }
::= { cmplsTunnelExtEntry 2 }
cmplsTunnelExtDestTnlIndex OBJECT-TYPE
SYNTAX MplsTunnelIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is applicable only for the bidirectional
tunnel that has the forward and reverse LSPs in the
same tunnel or in the different tunnels.
This object holds the same value as that of the
mplsTunnelIndex of mplsTunnelEntry if the forward and
reverse LSPs are in the same tunnel. Otherwise,
this object holds the value of the other direction
associated LSP's mplsTunnelIndex from a different
tunnel.
The values of this object and the
mplsTunnelExtDestTnlLspIndex object together can be used
to identify an opposite direction LSP i.e. if the
mplsTunnelIndex and mplsTunnelInstance hold the value
for forward LSP, this object and
mplsTunnelExtDestTnlLspIndex can be used to retrieve
the reverse direction LSP and vice versa.
This object and mplsTunnelExtDestTnlLspIndex values
provide the first two indices of tunnel entry and
the remaining indices can be derived as follows,
if both the forward and reverse LSPs are present in
the same tunnel, the opposite direction LSP's Ingress
and Egress Identifier will be same for both the LSPs,
else the Ingress and Egress Identifiers should be
swapped in order to index the other direction tunnel."
::= { cmplsTunnelExtEntry 3 }
cmplsTunnelExtDestTnlLspIndex OBJECT-TYPE
SYNTAX MplsTunnelInstanceIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is applicable only for the bidirectional
tunnel that has the forward and reverse LSPs in the
same tunnel or in the different tunnels.
This object should contain different value if both the
forward and reverse LSPs present in the same tunnel.
This object can contain same value or different values
if the forward and reverse LSPs present in the different
tunnels."
::= { cmplsTunnelExtEntry 4 }
cmplsTunnelExtDestTnlValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Denotes whether or not this tunnel uses
mplsTunnelExtDestTnlIndex and
mplsTunnelExtDestTnlLspIndex for identifying
the opposite direction tunnel information. Note that if
this variable is set to true then the
mplsTunnelExtDestTnlIndex and
mplsTunnelExtDestTnlLspIndex objects should have
the valid opposite direction tunnel indices."
DEFVAL { false }
::= { cmplsTunnelExtEntry 5 }
-- End of MPLS Tunnel table extension
cmplsTunnelReversePerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF CmplsTunnelReversePerfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table extends the mplsTunnelTable to provide
per-tunnel packet performance information for the reverse
direction of a bidirectional tunnel. It can be seen as
supplementing the mplsTunnelPerfTable, which augments the
mplsTunnelTable.
For links that do not transport packets, these packet
counters cannot be maintained. For such links, attempts
to read the objects in this table will return
noSuchInstance."
REFERENCE
"1. Multiprotocol Label Switching (MPLS) Traffic
Engineering (TE)Management Information Base (MIB),
RFC 3812."
::= { cmplsTeExtObjects 5 }
cmplsTunnelReversePerfEntry OBJECT-TYPE
SYNTAX CmplsTunnelReversePerfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table is created by the LSR for every
bidirectional MPLS tunnel where packets are visible to the
LSR."
INDEX {
mplsTunnelIndex,
mplsTunnelInstance,
mplsTunnelIngressLSRId,
mplsTunnelEgressLSRId
}
::= { cmplsTunnelReversePerfTable 1 }
CmplsTunnelReversePerfEntry ::= SEQUENCE {
cmplsTunnelReversePerfPackets Counter32,
cmplsTunnelReversePerfHCPackets Counter64,
cmplsTunnelReversePerfErrors Counter32,
cmplsTunnelReversePerfBytes Counter32,
cmplsTunnelReversePerfHCBytes Counter64
}
cmplsTunnelReversePerfPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of packets forwarded on the tunnel in the reverse
direction if it is bidirectional.
This object represents the 32-bit value of the least
significant part of the 64-bit value if both
mplsTunnelReversePerfHCPackets and this object
are returned.
For links that do not transport packets, this packet
counter cannot be maintained. For such links, this value
will return noSuchInstance."
::= { cmplsTunnelReversePerfEntry 1 }
cmplsTunnelReversePerfHCPackets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High-capacity counter for number of packets forwarded on
the tunnel in the reverse direction if it is
bidirectional.
For links that do not transport packets, this packet
counter cannot be maintained. For such links, this value
will return noSuchInstance."
::= { cmplsTunnelReversePerfEntry 2 }
cmplsTunnelReversePerfErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of errored packets received on the tunnel in
the reverse direction if it is bidirectional. For links
that do not transport packets, this packet counter cannot
be maintained. For such links, this value will return
noSuchInstance."
::= { cmplsTunnelReversePerfEntry 3 }
cmplsTunnelReversePerfBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of bytes forwarded on the tunnel in the reverse
direction if it is bidirectional.
This object represents the 32-bit value of the least
significant part of the 64-bit value if both
mplsTunnelReversePerfHCBytes and this object are returned.
For links that do not transport packets, this packet
counter cannot be maintained. For such links, this value
will return noSuchInstance."
::= { cmplsTunnelReversePerfEntry 4 }
cmplsTunnelReversePerfHCBytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High-capacity counter for number of bytes forwarded on the
tunnel in the reverse direction if it is bidirectional.
For links that do not transport packets, this packet
counter cannot be maintained. For such links, this value
will return noSuchInstance."
::= { cmplsTunnelReversePerfEntry 5 }
-- Notifications.
-- Notifications objects need to be added here.
-- End of notifications.
--
-- Module compliance.
cmplsTeExtGroups OBJECT IDENTIFIER
::= { cmplsTeExtConformance 1 }
cmplsTeExtCompliances OBJECT IDENTIFIER
::= { cmplsTeExtConformance 2 }
-- Compliance requirement for fully compliant implementations.
cmplsTeExtModuleFullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance statement for agents that provide full
support the MPLS-TE-EXT-STD-MIB module."
MODULE -- this module
MANDATORY-GROUPS { cmplsTunnelExtGroup }
GROUP cmplsTunnelExtIpOperatorGroup
DESCRIPTION
"This group is mandatory for devices which support
configuration of IP based identifier tunnels."
GROUP cmplsTunnelExtIccOperatorGroup
DESCRIPTION
"This group is mandatory for devices which support
configuration of ICC based tunnels."
::= { cmplsTeExtCompliances 1 }
-- Compliance requirement for read-only implementations.
cmplsTeExtModuleReadOnlyCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance statement for agents that provide full
support the MPLS-TE-EXT-STD-MIB module."
MODULE -- this module
MANDATORY-GROUPS { cmplsTunnelExtGroup }
GROUP cmplsTunnelExtIpOperatorGroup
DESCRIPTION
"This group is mandatory for devices which support
configuration of IP based identifier tunnels."
GROUP cmplsTunnelExtIccOperatorGroup
DESCRIPTION
"This group is mandatory for devices which support
configuration of ICC based tunnels."
::= { cmplsTeExtCompliances 2 }
-- Units of conformance.
cmplsTunnelExtGroup OBJECT-GROUP
OBJECTS {
cmplsTunnelOppositeDirPtr,
cmplsTunnelExtOppositeDirTnlValid,
cmplsTunnelExtDestTnlIndex,
cmplsTunnelExtDestTnlLspIndex,
cmplsTunnelExtDestTnlValid,
cmplsTunnelReversePerfPackets,
cmplsTunnelReversePerfHCPackets,
cmplsTunnelReversePerfErrors,
cmplsTunnelReversePerfBytes,
cmplsTunnelReversePerfHCBytes
}
STATUS current
DESCRIPTION
"Necessary, but not sufficient, set of objects to
implement tunnels. In addition, depending on the
operating environment, the following groups are
mandatory."
::= { cmplsTeExtGroups 1 }
cmplsTunnelExtIpOperatorGroup OBJECT-GROUP
OBJECTS {
cmplsNodeConfigGlobalId,
cmplsNodeConfigNodeId,
cmplsNodeConfigRowStatus,
cmplsNodeConfigStorageType,
cmplsNodeIpMapLocalId
}
STATUS current
DESCRIPTION
"Object(s) needed to implement IP compatible tunnels."
::= { cmplsTeExtGroups 2 }
cmplsTunnelExtIccOperatorGroup OBJECT-GROUP
OBJECTS {
cmplsNodeConfigIccId,
cmplsNodeConfigRowStatus,
cmplsNodeConfigStorageType,
cmplsNodeIccMapLocalId
}
STATUS current
DESCRIPTION
"Object(s) needed to implement ICC based tunnels."
::= { cmplsTeExtGroups 3 }
END