-- CISCO-DMN-DSG-Cueing.mib: MIB file for Board Cueing information.
|
|
--
|
|
-- August 2010, Hemant Kumar R
|
|
--
|
|
-- Copyright (c) 2010 by Cisco Systems, Inc.
|
|
-- All rights reserved.
|
|
--*****************************************************************
|
|
|
|
CISCO-DMN-DSG-Cueing-MIB
|
|
|
|
DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
OBJECT-TYPE,
|
|
MODULE-IDENTITY, Integer32
|
|
FROM SNMPv2-SMI
|
|
OBJECT-GROUP, MODULE-COMPLIANCE
|
|
FROM SNMPv2-CONF
|
|
ciscoDSGUtilities
|
|
FROM CISCO-DMN-DSG-ROOT-MIB;
|
|
|
|
|
|
ciscoDSGCueing MODULE-IDENTITY
|
|
LAST-UPDATED "201008300800Z" -- August 30 2010 08:00:00 GMT
|
|
ORGANIZATION "Cisco Systems, Inc."
|
|
CONTACT-INFO
|
|
"Cisco Systems, Inc.
|
|
Customer Service
|
|
Postal: 170 W Tasman Drive
|
|
San Jose, CA 95134
|
|
USA
|
|
Tel: +1 800 553 NETS
|
|
|
|
E-mail: cs-ipsla@cisco.com"
|
|
DESCRIPTION "Cisco Cueing MIB."
|
|
|
|
REVISION "201008300800Z"
|
|
DESCRIPTION "V01.00.00 2010-08-30
|
|
Initial Version."
|
|
|
|
::= { ciscoDSGUtilities 33 }
|
|
|
|
cueingTable OBJECT IDENTIFIER ::= { ciscoDSGCueing 11 }
|
|
|
|
--*****************************
|
|
-- Cueing Branch
|
|
--*****************************
|
|
cueingMode OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
trigger(1),
|
|
tone(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selection of Cueing Mode."
|
|
::= { ciscoDSGCueing 1 }
|
|
|
|
cueingTrigPol OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
low(1),
|
|
high(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selection of Cueing Trigger Polarity."
|
|
::= { ciscoDSGCueing 2 }
|
|
|
|
cueingRepeatCnt OBJECT-TYPE
|
|
SYNTAX Integer32 (1..3)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cueing Tone repeat count."
|
|
::= { ciscoDSGCueing 3 }
|
|
|
|
cueingTone OBJECT-TYPE
|
|
SYNTAX Integer32 (0..80)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cueing Tone duration in milliseconds."
|
|
::= { ciscoDSGCueing 4 }
|
|
|
|
cueingSilence OBJECT-TYPE
|
|
SYNTAX Integer32 (0..80)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Silence duration in milliseconds."
|
|
::= { ciscoDSGCueing 5 }
|
|
|
|
cueingRelayMode OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
alarm(1),
|
|
trigger(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selection of Relay Mode."
|
|
::= { ciscoDSGCueing 6 }
|
|
|
|
cueingRelayTrigBit OBJECT-TYPE
|
|
SYNTAX Integer32 (1..8)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selection of Relay trigger bit."
|
|
::= { ciscoDSGCueing 7 }
|
|
|
|
cueingTestToneSequence OBJECT-TYPE
|
|
SYNTAX Integer32 (0..999)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cueing test tone sequence."
|
|
::= { ciscoDSGCueing 8 }
|
|
|
|
cueingTestToneStartStop OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
start(1),
|
|
stop(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cueing test tone start/stop."
|
|
::= { ciscoDSGCueing 9 }
|
|
|
|
cueingTestToneGo OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
no(1),
|
|
yes(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cueing test tone go."
|
|
::= { ciscoDSGCueing 10 }
|
|
|
|
--*****************************
|
|
-- Cueing Table Branch
|
|
--*****************************
|
|
|
|
--**************************************
|
|
-- Cueing Tone Sequence Table Branch
|
|
--**************************************
|
|
cueingToneSeqTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CueingToneSeqEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cueing Tone sequence Table."
|
|
::= { cueingTable 1}
|
|
|
|
cueingToneSeqEntry OBJECT-TYPE
|
|
SYNTAX CueingToneSeqEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry for Cueing tone table."
|
|
INDEX { cueingToneSeqNum }
|
|
::= { cueingToneSeqTable 1 }
|
|
|
|
CueingToneSeqEntry ::= SEQUENCE
|
|
{
|
|
cueingToneSeqNum Integer32,
|
|
cueingToneSeqState INTEGER,
|
|
cueingToneSeqTones Integer32,
|
|
cueingToneSeqMode INTEGER,
|
|
cueingToneSeqDelay Integer32
|
|
}
|
|
|
|
cueingToneSeqNum OBJECT-TYPE
|
|
SYNTAX Integer32 (1..16)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cueing Tone sequence number selection."
|
|
::= { cueingToneSeqEntry 1 }
|
|
|
|
cueingToneSeqState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(1),
|
|
enable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contact Tone Sequence state selection."
|
|
::= { cueingToneSeqEntry 2 }
|
|
|
|
cueingToneSeqTones OBJECT-TYPE
|
|
SYNTAX Integer32 (0..999)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cueing Tone sequence tones."
|
|
::= { cueingToneSeqEntry 3 }
|
|
|
|
cueingToneSeqMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
start(1),
|
|
stop(2),
|
|
both(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contact Tone Sequence mode selection."
|
|
::= { cueingToneSeqEntry 4 }
|
|
|
|
cueingToneSeqDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cueing Tone sequence delay in seconds."
|
|
::= { cueingToneSeqEntry 5 }
|
|
|
|
END
|