Observium_CE/mibs/ciena/WWP-LEOS-OAM-MIB

1956 lines
121 KiB
Plaintext

-- This file was included in WWP MIB release 04-10-01-0027
--
-- WWP-LEOS-OAM-MIB.my
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
WWP-LEOS-OAM-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
Integer32, Unsigned32, Counter32, Counter64, OBJECT-TYPE,
NOTIFICATION-TYPE, MODULE-IDENTITY
FROM SNMPv2-SMI
TimeStamp, TruthValue
FROM SNMPv2-TC
wwpModulesLeos
FROM WWP-SMI
wwpLeosEtherPortDesc, wwpLeosEtherPortOperStatus
FROM WWP-LEOS-PORT-MIB;
-- 1.3.6.1.4.1.6141.2.60.400
wwpLeosOamMibModule MODULE-IDENTITY
LAST-UPDATED "200801030000Z" -- January 3,2008 at 00:00GMT
ORGANIZATION "Ciena, Inc"
CONTACT-INFO
" Mib Meister
115 North Sullivan Road
Spokane Valley, WA 99037
USA
Phone: +1 509 242 9000
Email: support@ciena.com"
DESCRIPTION
"The MIB module for managing the new Ethernet OAM features
introduced by the Ethernet in the First Mile task force (IEEE
802.3ah). The functionality presented here is based on IEEE
802.3ah [802.3ah], released in October, 2004.
In particular, this MIB focused on the changes to Clause 30 of
the draft that are not specific to any physical layer. These
changes are primarily reflected in the new OAM features
developed under this project, that can be applied to any
Ethernet like interface. The OAM features are described in
Clause 57 of [802.3ah].
The following reference is used throughout this MIB module:
[802.3ah] refers to:
IEEE Std 802.3ah-2004: 'Draft amendment to -
Information technology - Telecommunications and
information exchange between systems - Local and
metropolitan are networks - Specific requirements - Part
3: Carrier sense multiple access with collision detection
(CSMA/CD) access method and physical layer specifications
- Media Access Control Parameters, Physical Layers and
Management Parameters for subscriber access networks',
October 2004.
[802-2001] refers to:
'IEEE Standard for LAN/MAN (Local Area
Network/Metropolitan Area Network): Overview and
Architecture', IEEE 802, June 2001.
Copyright (c) The Internet Society (2005). This version of
this MIB module is part of RFC XXXX; See the RFC itself for
full legal notices."
REVISION "200801030000Z"
DESCRIPTION
"Initial creation."
::= { wwpModulesLeos 400 }
--
-- Node definitions
--
-- 1.3.6.1.4.1.6141.2.60.400.1
wwpLeosOamMIB OBJECT IDENTIFIER ::= { wwpLeosOamMibModule 1 }
-- 1.3.6.1.4.1.6141.2.60.400.1.1
wwpLeosOamConf OBJECT IDENTIFIER ::= { wwpLeosOamMIB 1 }
-- 1.3.6.1.4.1.6141.2.60.400.1.1.1
wwpLeosOamGroups OBJECT IDENTIFIER ::= { wwpLeosOamConf 1 }
-- 1.3.6.1.4.1.6141.2.60.400.1.1.1.1
--wwpLeosOamObjectGroup OBJECT-GROUP
-- OBJECTS { object1 }
-- STATUS current
-- DESCRIPTION
-- "Description."
-- ::= { wwpLeosOamGroups 1 }
-- 1.3.6.1.4.1.6141.2.60.400.1.1.1.2
--wwpLeosOamNotificationGroup NOTIFICATION-GROUP
-- NOTIFICATIONS { notification1 }
-- STATUS current
-- DESCRIPTION
-- "Description."
-- ::= { wwpLeosOamGroups 2 }
-- 1.3.6.1.4.1.6141.2.60.400.1.1.2
wwpLeosOamCompls OBJECT IDENTIFIER ::= { wwpLeosOamConf 2 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2
wwpLeosOamObjs OBJECT IDENTIFIER ::= { wwpLeosOamMIB 2 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.1
wwpLeosOamTable OBJECT-TYPE
SYNTAX SEQUENCE OF WwpLeosOamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Primary controls and status for the OAM capabilities of an
Ethernet like interface. There will be one row in this table
for each Ethernet like interface in the system that supports
the Ethernet OAM functions defined in [802.3ah]."
::= { wwpLeosOamObjs 1 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.1.1
wwpLeosOamEntry OBJECT-TYPE
SYNTAX WwpLeosOamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table. Contains an Ethernet like interface
in the system that supports the Ethernet OAM functions
defined in [802.3ah]."
INDEX { wwpLeosOamPort }
::= { wwpLeosOamTable 1 }
WwpLeosOamEntry ::=
SEQUENCE {
wwpLeosOamAdminState
INTEGER,
wwpLeosOamOperStatus
INTEGER,
wwpLeosOamMode
INTEGER,
wwpLeosMaxOamPduSize
Integer32,
wwpLeosOamConfigRevision
Unsigned32,
wwpLeosOamFunctionsSupported
BITS,
wwpLeosOamPort
Integer32,
wwpLeosOamPduTimer
INTEGER,
wwpLeosOamLinkLostTimer
INTEGER,
wwpLeosOamPeerStatusNotifyState
INTEGER
}
-- 1.3.6.1.4.1.6141.2.60.400.1.2.1.1.1
wwpLeosOamAdminState OBJECT-TYPE
SYNTAX INTEGER
{
disabled(1),
enabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to provision the default administrative OAM mode for this
interface. This object represents the desired state of OAM for this interface.
The wwpLeosOamAdminState always starts in the disabled(1) state
until an explicit management action or configuration
information retained by the system causes a transition to the
enabled(2) state.
Note that the value of this object is ignored when the
interface is not operating in full-duplex mode. OAM is not
supported on half-duplex links."
::= { wwpLeosOamEntry 1 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.1.1.2
wwpLeosOamOperStatus OBJECT-TYPE
SYNTAX INTEGER
{
disabled(1),
linkfault(2),
passiveWait(3),
activeSendLocal(4),
sendLocalAndRemote(5),
sendLocalAndRemoteOk(6),
oamPeeringLocallyRejected(7),
oamPeeringRemotelyRejected(8),
operational(9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"At initialization and failure conditions, two OAM entities on
the same full-duplex Ethernet link begin a discovery phase to
determine what OAM capabilities may be used on that link. The
progress of this initialization is controlled by the OAM
sub layer.
This value is always disabled(1) if OAM is disabled on this
interface via the wwpLeosOamAdminState.
If the link has detected a fault and is transmitting OAMPDUs
with a link fault indication, the value is linkFault(2).
The passiveWait(3) state is returned only by OAM entities in
passive mode (wwpLeosOamMode) and reflects the state in which the
OAM entity is waiting to see if the peer device is OAM
capable. The activeSendLocal(4) is used by active mode
devices (wwpLeosOamMode) and reflects the OAM entity actively
trying to discover whether the peer has OAM capability but has
not yet made that determination.
The state sendLocalAndRemote(5) reflects that the local OAM
entity has discovered the peer but has not yet accepted or
rejected the configuration of the peer. The local device can,
for whatever reason, decide that the peer device is
unacceptable and decline OAM peering. If the local OAM entity
rejects the peer OAM entity, the state becomes
oamPeeringLocallyRejected(7). If the OAM peering is allowed
by the local device, the state moves to
sendLocalAndRemoteOk(6). Note that both the
sendLocalAndRemote(5) and oamPeeringLocallyRejected(7) states
fall within the state SEND_LOCAL_REMOTE of the Discovery state
diagram [802.3ah, Figure 57-5], with the difference being
whether the local OAM client has actively rejected the peering
or has just not indicated any decision yet. Whether a peering
decision has been made is indicated via the local flags field
in the OAMPDU (reflected in the aOAMLocalFlagsField of
30.3.6.1.10).
If the remote OAM entity rejects the peering, the state
becomes oamPeeringRemotelyRejected(8). Note that both the
sendLocalAndRemoteOk(6) and oamPeeringRemotelyRejected(8)
states fall within the state SEND_LOCAL_REMOTE_OK of the
Discovery state diagram [802.3ah, Figure 57-5], with the
difference being whether the remote OAM client has rejected
the peering or has just not yet decided. This is indicated
via the remote flags field in the OAM PDU (reflected in the
aOAMRemoteFlagsField of 30.3.6.1.11).
When the local OAM entity learns that both it and the remote
OAM entity have accepted the peering, the state moves to
operational(9) corresponding to the SEND_ANY state of the
Discovery state diagram [802.3ah, Figure 57-5]. "
::= { wwpLeosOamEntry 2 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.1.1.3
wwpLeosOamMode OBJECT-TYPE
SYNTAX INTEGER
{
active(1),
passive(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures the mode of OAM operation for this
Ethernet like interface. OAM on Ethernet interfaces may be in
'active' mode or 'passive' mode. These two modes differ in
that active mode provides additional capabilities to initiate
monitoring activities with the remote OAM peer entity, while
passive mode generally waits for the peer to initiate OAM
actions with it. As an example, an active OAM entity can put
the remote OAM entity in a loopback state, where a passive OAM
entity cannot.
The default value of wwpLeosOamMode is dependent on the type of
system on which this Ethernet like interface resides. The
default value should be 'active(1)' unless it is known that
this system should take on a subservient role to the other
device connected over this interface.
Changing this value results in incrementing the configuration
revision field of locally generated OAMPDUs (30.3.6.1.12) and
potentially re-doing the OAM discovery process if the
wwpLeosOamOperStatus was already operational(9). "
::= { wwpLeosOamEntry 3 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.1.1.4
wwpLeosMaxOamPduSize OBJECT-TYPE
SYNTAX Integer32
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The largest OAMPDU that the OAM entity supports. OAM
entities exchange maximum OAMPDU sizes and negotiate to use
the smaller of the two maximum OAMPDU sizes between the peers.
This value is determined by the local implementation."
::= { wwpLeosOamEntry 4 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.1.1.5
wwpLeosOamConfigRevision OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The configuration revision of the OAM entity as reflected in
the latest OAMPDU sent by the OAM entity. The configuration revision
is used by OAM entities to indicate configuration changes have
occurred which might require the peer OAM entity to re-evaluate
whether the peering is allowed. See local_satisfied in
[802.3ah, 57.3.1.2]."
::= { wwpLeosOamEntry 5 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.1.1.6
wwpLeosOamFunctionsSupported OBJECT-TYPE
SYNTAX BITS
{
unidirectionalSupport(0),
loopbackSupport(1),
eventSupport(2),
variableSupport(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The OAM functions supported on this Ethernet like interface.
OAM consists of separate functional sets beyond the basic
discovery process which is always required. These functional
groups can be supported independently by any implementation.
These values are communicated to the peer via the local
configuration field of Information OAMPDUs. "
::= { wwpLeosOamEntry 6 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.1.1.7
wwpLeosOamPort OBJECT-TYPE
SYNTAX Integer32 (1..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An Ethernet port on the switch."
::= { wwpLeosOamEntry 7 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.1.1.8
wwpLeosOamPduTimer OBJECT-TYPE
SYNTAX INTEGER (100..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time in milliseconds between Information OAMPDUs
being transmitted via the Ethernet port."
::= { wwpLeosOamEntry 8 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.1.1.9
wwpLeosOamLinkLostTimer OBJECT-TYPE
SYNTAX INTEGER (500..5000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time in milliseconds to wait for an Information OAMPDU
via the Ethernet port, from a peer, before declaring the link lost."
::= { wwpLeosOamEntry 9 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.1.1.10
wwpLeosOamPeerStatusNotifyState OBJECT-TYPE
SYNTAX INTEGER
{
on(1),
off(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether or not a change in peer status, IE whether or not a Link Lost
Timer is active for the peer, should result in a system event being
generated."
::= { wwpLeosOamEntry 10 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.2
wwpLeosOamPeerTable OBJECT-TYPE
SYNTAX SEQUENCE OF WwpLeosOamPeerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about the OAM peer for a particular Ethernet like
interface. OAM entities communicate with a single OAM peer
entity on full-duplex Ethernet links on which OAM is enabled
and operating properly.
In certain states, the OAM peer information is not available.
Whether peer information is available is communicated via the
wwpLeosOamPeerStatus object. When this object is inactive, all
other information in the row is to be considered invalid."
::= { wwpLeosOamObjs 2 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.2.1
wwpLeosOamPeerEntry OBJECT-TYPE
SYNTAX WwpLeosOamPeerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table, containing information on the peer OAM
entity for a single Ethernet like interface.
Note that there is at most one OAM peer for each Ethernet like
interface. There is exactly one row in this table for each
Ethernet like interface supporting OAM. "
INDEX { wwpLeosOamLocalPort }
::= { wwpLeosOamPeerTable 1 }
WwpLeosOamPeerEntry ::=
SEQUENCE {
wwpLeosOamPeerStatus INTEGER,
wwpLeosOamPeerMacAddress OCTET STRING,
wwpLeosOamPeerVendorOui OCTET STRING,
wwpLeosOamPeerVendorInfo Unsigned32,
wwpLeosOamPeerMode INTEGER,
wwpLeosOamPeerMaxOamPduSize Integer32,
wwpLeosOamPeerConfigRevision Unsigned32,
wwpLeosOamPeerFunctionsSupported BITS,
wwpLeosOamLocalPort Integer32
}
-- 1.3.6.1.4.1.6141.2.60.400.1.2.2.1.1
wwpLeosOamPeerStatus OBJECT-TYPE
SYNTAX INTEGER
{
active(1),
inactive(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates whether the information in this row
should be considered valid. When active(1), the information
is valid and represents the current peer of the OAM entity.
When inactive(2), the information in this row is invalid.
A value of inactive(2) is returned if the wwpLeosOamOperStatus is
disabled, passiveWait, or activeSendLocal. For all other
values of wwpLeosOamOperStatus, a value of active(1) is returned."
::= { wwpLeosOamPeerEntry 1 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.2.1.2
wwpLeosOamPeerMacAddress OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MAC address of the peer OAM entity. The MAC address is
derived from the most recently received OAMPDU. This value is
initialized to all zeros (0x000000000000). This value is
invalid if the wwpLeosOamPeerStatus is inactive.
An OAMPDU is indicated by a valid frame with (1) destination
MAC address equal to that of the reserved MAC address for Slow
Protocols (See 43B of [802.3ah]), (2) a lengthOrType field
equal to the reserved type for Slow Protocols, (3) and a Slow
Protocols subtype equal to that of the subtype reserved for
OAM."
::= { wwpLeosOamPeerEntry 2 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.2.1.3
wwpLeosOamPeerVendorOui OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(3))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The OUI of the OAM peer as reflected in the latest
Information OAMPDU received with a Local Information TLV. The
OUI can be used to identify the vendor of the remote OAM
entity. This value is initialized to all zeros (0x000000).
This value is considered invalid if the wwpLeosOamPeerStatus is
inactive.
An Information OAMPDU is indicated by a valid frame with (1)
destination MAC address equal to that of the reserved MAC
address for Slow Protocols (See 43B of [802.3ah]), (2) a
lengthOrType field equal to the reserved type for Slow Protocols, (3) a Slow Protocols subtype equal to that of the
subtype reserved for OAM, (4) a OAM code that equals the code
reserved for Information OAMPDUs."
::= { wwpLeosOamPeerEntry 3 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.2.1.4
wwpLeosOamPeerVendorInfo OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Vendor Info of the OAM peer as reflected in the latest
Information OAMPDU received with a Local Information TLV. The
vendor information field is within the Local Information TLV,
and can be used to determine additional information about the
peer entity. The format of the vendor information is
unspecified within the 32-bit field. This value is initialized
to all zeros (0x00000000). This value is invalid if the
wwpLeosOamPeerStatus is inactive.
An Information OAMPDU is indicated by a valid frame with (1)
destination MAC address equal to that of the reserved MAC
address for Slow Protocols (See 43B of [802.3ah]), (2) a
lengthOrType field equal to the reserved type for Slow
Protocols, (3) a Slow Protocols subtype equal to that of the
subtype reserved for OAM, and (4) a OAM code that equals the
code reserved for Information OAMPDUs. "
::= { wwpLeosOamPeerEntry 4 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.2.1.5
wwpLeosOamPeerMode OBJECT-TYPE
SYNTAX INTEGER
{
active(1),
passive(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mode of the OAM peer as reflected in the latest
Information OAMPDU received with a Local Information TLV. The
mode of the peer can be determined from the Configuration
field in the Local Information TLV of the last Information
OAMPDU received from the peer. This value is initialized to
unknown(3), and is not valid if the wwpLeosOamPeerStatus is
inactive.
An Information OAMPDU is indicated by a valid frame with (1)
destination MAC address equal to that of the reserved MAC
address for Slow Protocols (See 43B of [802.3ah]), (2) a
lengthOrType field equal to the reserved type for Slow
Protocols, (3) a Slow Protocols subtype equal to that of the
subtype reserved for OAM, and (4) a OAM code that equals the
code reserved for Information OAMPDUs."
::= { wwpLeosOamPeerEntry 5 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.2.1.6
wwpLeosOamPeerMaxOamPduSize OBJECT-TYPE
SYNTAX Integer32
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum size of OAMPDU supported by the peer as reflected
in the latest Information OAMPDU received with a Local
Information TLV. Ethernet OAM on this interface must not use
OAMPDUs that exceed this size. The maximum OAMPDU size can be
determined from the PDU Configuration field of the Local
Information TLV of the last Information OAMPDU received from
the peer. This value is initialized to 64, and is invalid if
the wwpLeosOamPeerStatus is inactive.
An Information OAMPDU is indicated by a valid frame with (1)
destination MAC address equal to that of the reserved MAC
address for Slow Protocols (See 43B of [802.3ah]), (2) a
lengthOrType field equal to the reserved type for Slow
Protocols, (3) a Slow Protocols subtype equal to that of the
subtype reserved for OAM, and (4) a OAM code that equals the
code reserved for Information OAMPDUs."
::= { wwpLeosOamPeerEntry 6 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.2.1.7
wwpLeosOamPeerConfigRevision OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The configuration revision of the OAM peer as reflected in
the latest OAMPDU. This attribute is changed by the peer
whenever it has a local configuration change for Ethernet OAM
this interface. This value is initialized to all zeros
(0x00000000), and is invalid if the wwpLeosOamPeerStatus is
inactive.
The configuration revision can be determined from the Revision
field of the Local Information TLV of the most recently
received Information OAMPDU with a Local Information TLV.
An Information OAMPDU is indicated by a valid frame with (1)
destination MAC address equal to that of the reserved MAC
address for Slow Protocols (See 43B of [802.3ah]), (2) a
lengthOrType field equal to the reserved type for Slow
Protocols, (3) a Slow Protocols subtype equal to that of the
subtype reserved for OAM, and (4) a OAM code that equals the
code reserved for Information OAMPDUs."
::= { wwpLeosOamPeerEntry 7 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.2.1.8
wwpLeosOamPeerFunctionsSupported OBJECT-TYPE
SYNTAX BITS
{
unidirectionalSupport(0),
loopbackSupport(1),
eventSupport(2),
variableSupport(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The OAM functions supported on this Ethernet like interface.
OAM consists of separate functionality sets above the basic
discovery process. This value indicates the capabilities of
the peer OAM entity with respect to these functions. This
value is initialized so all bits are clear, and is invalid if
the wwpLeosOamPeerStatus is inactive.
The capbilities of the OAM peer can be determined from the
configuration field of the Local Information TLV of the most
recently received Information OAMPDU with a Local Information
TLV.
An Information OAMPDU is indicated by a valid frame with (1)
destination MAC address equal to that of the reserved MAC
address for Slow Protocols (See 43B of [802.3ah]), (2) a
lengthOrType field equal to the reserved type for Slow
Protocols, (3) a Slow Protocols subtype equal to that of the
subtype reserved for OAM, and (4) a OAM code that equals the
code reserved for Information OAMPDUs. "
::= { wwpLeosOamPeerEntry 8 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.2.1.9
wwpLeosOamLocalPort OBJECT-TYPE
SYNTAX Integer32 (1..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An Ethernet port on the local switch."
::= { wwpLeosOamPeerEntry 9 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.3
wwpLeosOamLoopbackTable OBJECT-TYPE
SYNTAX SEQUENCE OF WwpLeosOamLoopbackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains methods to control the loopback state of
the local link as well as indicating the status of the
loopback function.
Loopback can be used to place the remote OAM entity in a state
where every received frame (except OAMPDUs) are echoed back
over the same interface on which they were received. In this
state, at the remote entity, 'normal' traffic is disabled as
only the looped back frames are transmitted on the interface.
Loopback is thus an intrusive operation that prohibits normal
data flow and should be used accordingly."
::= { wwpLeosOamObjs 3 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.3.1
wwpLeosOamLoopbackEntry OBJECT-TYPE
SYNTAX WwpLeosOamLoopbackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table, containing information on the loopback
status for a single Ethernet like interface. There is an
entry in this table for every Ethernet like interface on which
supports OAM and loopback function within OAM (as indicated in
wwpLeosOamFunctionsSupported)."
INDEX { wwpLeosOamLoopbackPort }
::= { wwpLeosOamLoopbackTable 1 }
WwpLeosOamLoopbackEntry ::=
SEQUENCE {
wwpLeosOamLoopbackCommand
INTEGER,
wwpLeosOamLoopbackStatus
INTEGER,
wwpLeosOamLoopbackIgnoreRx
INTEGER,
wwpLeosOamLoopbackPort
Integer32
}
-- 1.3.6.1.4.1.6141.2.60.400.1.2.3.1.1
wwpLeosOamLoopbackCommand OBJECT-TYPE
SYNTAX INTEGER
{
noLoopback(1),
startRemoteLoopback(2),
stopRemoteLoopback(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute initiates or terminates remote loopback with
an OAM peer. Writing startRemoteLoopback(2) to this attribute
cause the local OAM client to send a loopback OAMPDU to the
OAM peer with the loopback enable flags set. Writing
stopRemoteLoopback(3) to this attribute will cause the local
OAM client to send a loopback OAMPDU to the OAM peer with the
loopback enable flags cleared. Writing noLoopback to this
attribute has no effect.
Writes to this attribute are ignored unless the OAM status of
this interface is 'operational' (wwpLeosOamOperStatus).
The attribute always returns noLoopback on a read. To
determine the loopback status, use the attribute
wwpLeosOamLoopbackStatus. "
::= { wwpLeosOamLoopbackEntry 1 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.3.1.2
wwpLeosOamLoopbackStatus OBJECT-TYPE
SYNTAX INTEGER
{
noLoopback(1),
initiatingLoopback(2),
remoteLoopback(3),
terminatingLoopback(4),
localLoopback(5),
unknown(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The loopback status of the OAM entity. This status is
determined by a combination of the local parser and
multiplexer states, the remote parser and multiplexer states,
as well as by the actions of the local OAM client. When
operating in normal mode with no loopback in progress, the
status reads noLoopback(1).
If the OAM client has sent an Loopback OAMPDU and is waiting
for a response, where the local parser and multiplexer states
are DISCARD (see [802.3ah, 57.2.11.1]), the status is
'initiatingLoopback'. In this case, the local OAM entity has
yet to receive any acknowledgement that the remote OAM entity
has received its loopback command request.
If the local OAM client knows that the remote OAM entity is in
loopback mode (via the remote state information as described
in [802.3ah, 57.2.11.1, 30.3.6.1.15]), the status is remoteLoopback(3). If the local OAM client is in the process
of terminating the remote loopback [802.3ah, 57.2.11.3,
30.3.6.1.14], with its local multiplexer and parser states in
DISCARD, the status is terminatingLoopback(4). If the remote
OAM client has put the local OAM entity in loopback mode as
indicated by its local parser state, the status is
localLoopback(5).
The unknown(6) status indicates the parser and multiplexer
combination is unexpected. This status may be returned if the
OAM loopback is in a transition state but should not persist.
The values of this attribute correspond to the following
values of the local and remote parser and multiplexer states.
value LclPrsr LclMux RmtPrsr RmtMux
noLoopback FWD FWD FWD FWD
initLoopback DISCARD DISCARD FWD FWD
rmtLoopback DISCARD FWD LPBK DISCARD
tmtngLoopback DISCARD DISCARD LPBK DISCARD
lclLoopback LPBK DISCARD DISCARD FWD
unknown *** any other combination ***"
::= { wwpLeosOamLoopbackEntry 2 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.3.1.3
wwpLeosOamLoopbackIgnoreRx OBJECT-TYPE
SYNTAX INTEGER
{
ignore(1),
process(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Since OAM loopback is a disruptive operation (user traffic
does not pass), this attribute provides a mechanism to provide
controls over whether received OAM loopback commands are
processed or ignored. When the value is ignore(1), received
loopback commands are ignored. When the value is process(2),
OAM loopback commands are processed. The default value is to
ignore loopback commands (ignore(1)).
The attribute has no meaning if the local OAM entity does not
support the loopback function (as defined in
wwpLeosOamFunctionsSupported). "
::= { wwpLeosOamLoopbackEntry 3 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.3.1.4
wwpLeosOamLoopbackPort OBJECT-TYPE
SYNTAX Integer32 (1..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An Ethernet port on the switch"
::= { wwpLeosOamLoopbackEntry 4 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.4
wwpLeosOamStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF WwpLeosOamStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Statistics for the OAM function on a particular Ethernet like
interface."
::= { wwpLeosOamObjs 4 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.4.1
wwpLeosOamStatsEntry OBJECT-TYPE
SYNTAX WwpLeosOamStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table, containing statistics information on
the Ethernet OAM function for a single Ethernet like
interface."
INDEX { wwpLeosOamStatsPort }
::= { wwpLeosOamStatsTable 1 }
WwpLeosOamStatsEntry ::=
SEQUENCE {
wwpLeosOamInformationTx
Counter32,
wwpLeosOamInformationRx
Counter32,
wwpLeosOamUniqueEventNotificationTx
Counter32,
wwpLeosOamUniqueEventNotificationRx
Counter32,
wwpLeosOamLoopbackControlTx
Counter32,
wwpLeosOamLoopbackControlRx
Counter32,
wwpLeosOamVariableRequestTx
Counter32,
wwpLeosOamVariableRequestRx
Counter32,
wwpLeosOamVariableResponseTx
Counter32,
wwpLeosOamVariableResponseRx
Counter32,
wwpLeosOamOrgSpecificTx
Counter32,
wwpLeosOamOrgSpecificRx
Counter32,
wwpLeosOamUnsupportedCodesTx
Counter32,
wwpLeosOamUnsupportedCodesRx
Counter32,
wwpLeosOamframesLostDueToOam
Counter32,
wwpLeosOamStatsPort
Integer32,
wwpLeosOamDuplicateEventNotificationTx
Counter32,
wwpLeosOamDuplicateEventNotificationRx
Counter32
}
-- 1.3.6.1.4.1.6141.2.60.400.1.2.4.1.1
wwpLeosOamInformationTx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of Information OAMPDUs transmitted on
this interface.
An Information OAMPDU is indicated by a valid frame with (1)
destination MAC address equal to that of the reserved MAC
address for Slow Protocols (See 43B of [802.3ah]), (2) a
lengthOrType field equal to the reserved type for Slow
Protocols, (3) a Slow Protocols subtype equal to that of the
subtype reserved for OAM, and (4) an OAMPDU code equals the
OAM Information code.
Discontinuities of this counter can occur at re-initialization
of the management system, and at other times as indicated by
the value of the ifCounterDiscontinuityTime."
::= { wwpLeosOamStatsEntry 1 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.4.1.2
wwpLeosOamInformationRx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of Information OAMPDUs received on this
interface.
An Information OAMPDU is indicated by a valid frame with (1)
destination MAC address equal to that of the reserved MAC
address for Slow Protocols (See 43B of [802.3ah]), (2) a
lengthOrType field equal to the reserved type for Slow
Protocols, (3) a Slow Protocols subtype equal to that of the
subtype reserved for OAM, and (4) an OAMPDU code equals the
OAM Information code.
Discontinuities of this counter can occur at re-initialization
of the management system, and at other times as indicated by
the value of the ifCounterDiscontinuityTime. "
::= { wwpLeosOamStatsEntry 2 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.4.1.3
wwpLeosOamUniqueEventNotificationTx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of unique Event OAMPDUs transmitted on
this interface. Event notifications may be sent in duplicate
to increase the probability of successfully being received,
given the possibility that a frame may be lost in transit.
An Event Notification OAMPDU is indicated by a valid frame
with (1) destination MAC address equal to that of the reserved
MAC address for Slow Protocols (See 43B of [802.3ah]), (2) a
lengthOrType field equal to the reserved type for Slow
Protocols, (3) a Slow Protocols subtype equal to that of the
subtype reserved for OAM, and (4) an OAMPDU code equals the
OAM Event code.
A unique Event Notification OAMPDU is indicated as an Event
Notification OAMPDU with a Sequence Number field that is
distinct from the previously transmitted Event Notification
OAMPDU Sequence Number.
Discontinuities of this counter can occur at re-initialization
of the management system, and at other times as indicated by
the value of the ifCounterDiscontinuityTime."
::= { wwpLeosOamStatsEntry 3 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.4.1.4
wwpLeosOamUniqueEventNotificationRx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of unique Event OAMPDUs received on
this interface. Event notification OAMPDUs may be sent in
duplicate to increase the probability of successfully being
received, given the possibility that a frame may be lost in
transit.
An Event Notification OAMPDU is indicated by a valid frame
with (1) destination MAC address equal to that of the reserved
MAC address for Slow Protocols (See 43B of [802.3ah]), (2) a
lengthOrType field equal to the reserved type for Slow
Protocols, (3) a Slow Protocols subtype equal to that of the
subtype reserved for OAM, and (4) an OAMPDU code equals the
OAM Event code.
A unique Event Notification OAMPDU is indicated as an Event
Notification OAMPDU with a Sequence Number field that is
distinct from the previously received Event Notification
OAMPDU Sequence Number.
Discontinuities of this counter can occur at re-initialization
of the management system, and at other times as indicated by
the value of the ifCounterDiscontinuityTime."
::= { wwpLeosOamStatsEntry 4 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.4.1.5
wwpLeosOamLoopbackControlTx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of Loopback Control OAMPDUs transmitted
on this interface.
An Loopback Control OAMPDU is indicated by a valid frame with
(1) destination MAC address equal to that of the reserved MAC
address for Slow Protocols (See 43B of [802.3ah]), (2) a
lengthOrType field equal to the reserved type for Slow
Protocols, (3) a Slow Protocols subtype equal to that of the
subtype reserved for OAM, and (4) an OAMPDU code equals the
OAM Loopback Control code.
Discontinuities of this counter can occur at re-initialization
of the management system, and at other times as indicated by
the value of the ifCounterDiscontinuityTime. "
REFERENCE "[802.3ah], 30.3.6.1.26."
::= { wwpLeosOamStatsEntry 5 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.4.1.6
wwpLeosOamLoopbackControlRx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of Loopback Control OAMPDUs transmitted
on this interface.
An Loopback Control OAMPDU is indicated by a valid frame with
(1) destination MAC address equal to that of the reserved MAC
address for Slow Protocols (See 43B of [802.3ah]), (2) a
lengthOrType field equal to the reserved type for Slow
Protocols, (3) a Slow Protocols subtype equal to that of the
subtype reserved for OAM, and (4) an OAMPDU code equals the
OAM Loopback Control code.
Discontinuities of this counter can occur at re-initialization
of the management system, and at other times as indicated by
the value of the ifCounterDiscontinuityTime. "
REFERENCE "[802.3ah], 30.3.6.1.27."
::= { wwpLeosOamStatsEntry 6 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.4.1.7
wwpLeosOamVariableRequestTx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of Variable Request OAMPDUs transmitted
on this interface.
An Variable Request OAMPDU is indicated by a valid frame with
(1) destination MAC address equal to that of the reserved MAC
address for Slow Protocols (See 43B of [802.3ah]), (2) a
lengthOrType field equal to the reserved type for Slow
Protocols, (3) a Slow Protocols subtype equal to that of the
subtype reserved for OAM, and (4) an OAMPDU code equals the
OAM Variable Request code.
Discontinuities of this counter can occur at re-initialization
of the management system, and at other times as indicated by
the value of the ifCounterDiscontinuityTime. "
REFERENCE "[802.3ah], 30.3.6.1.28."
::= { wwpLeosOamStatsEntry 7 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.4.1.8
wwpLeosOamVariableRequestRx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of Variable Request OAMPDUs received on
this interface.
An Variable Request OAMPDU is indicated by a valid frame with
(1) destination MAC address equal to that of the reserved MAC
address for Slow Protocols (See 43B of [802.3ah]), (2) a
lengthOrType field equal to the reserved type for Slow
Protocols, (3) a Slow Protocols subtype equal to that of the
subtype reserved for OAM, and (4) an OAMPDU code equals the
OAM Variable Request code.
Discontinuities of this counter can occur at re-initialization
of the management system, and at other times as indicated by
the value of the ifCounterDiscontinuityTime."
::= { wwpLeosOamStatsEntry 8 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.4.1.9
wwpLeosOamVariableResponseTx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of Variable Response OAMPDUs
transmitted on this interface.
An Variable Response OAMPDU is indicated by a valid frame with
(1) destination MAC address equal to that of the reserved MAC
address for Slow Protocols (See 43B of [802.3ah]), (2) a
lengthOrType field equal to the reserved type for Slow
Protocols, (3) a Slow Protocols subtype equal to that of the
subtype reserved for OAM, and (4) an OAMPDU code equals the
OAM Variable Response code.
Discontinuities of this counter can occur at re-initialization
of the management system, and at other times as indicated by
the value of the ifCounterDiscontinuityTime. "
::= { wwpLeosOamStatsEntry 9 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.4.1.10
wwpLeosOamVariableResponseRx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of Variable Response OAMPDUs received
on this interface.
An Variable Response OAMPDU is indicated by a valid frame with
(1) destination MAC address equal to that of the reserved MAC
address for Slow Protocols (See 43B of [802.3ah]), (2) a
lengthOrType field equal to the reserved type for Slow
Protocols, (3) a Slow Protocols subtype equal to that of the
subtype reserved for OAM, and (4) an OAMPDU code equals the
OAM Variable Response code.
Discontinuities of this counter can occur at re-initialization
of the management system, and at other times as indicated by
the value of the ifCounterDiscontinuityTime. "
::= { wwpLeosOamStatsEntry 10 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.4.1.11
wwpLeosOamOrgSpecificTx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of Organization Specific OAMPDUs
transmitted on this interface.
An Organization Specific OAMPDU is indicated by a valid frame
with (1) destination MAC address equal to that of the reserved
MAC address for Slow Protocols (See 43B of [802.3ah]), (2) a
lengthOrType field equal to the reserved type for Slow
Protocols, (3) a Slow Protocols subtype equal to that of the
subtype reserved for OAM, and (4) an OAMPDU code equals the
OAM Organization Specific code.
Discontinuities of this counter can occur at re-initialization
of the management system, and at other times as indicated by
the value of the ifCounterDiscontinuityTime. "
::= { wwpLeosOamStatsEntry 11 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.4.1.12
wwpLeosOamOrgSpecificRx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of Organization Specific OAMPDUs
received on this interface.
An Organization Specific OAMPDU is indicated by a valid frame
with (1) destination MAC address equal to that of the reserved
MAC address for Slow Protocols (See 43B of [802.3ah]), (2) a
lengthOrType field equal to the reserved type for Slow
Protocols, (3) a Slow Protocols subtype equal to that of the
subtype reserved for OAM, and (4) an OAMPDU code equals the
OAM Organization Specific code.
Discontinuities of this counter can occur at re-initialization
of the management system, and at other times as indicated by
the value of the ifCounterDiscontinuityTime. "
::= { wwpLeosOamStatsEntry 12 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.4.1.13
wwpLeosOamUnsupportedCodesTx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of OAMPDUs transmitted on this
interface with an unsupported op-code.
An unsupported op-code OAMPDU is indicated by a valid frame
with (1) destination MAC address equal to that of the reserved
MAC address for Slow Protocols (See 43B of [802.3ah]), (2) a
lengthOrType field equal to the reserved type for Slow
Protocols, (3) a Slow Protocols subtype equal to that of the
subtype reserved for OAM, and (4) an OAMPDU code equals the
op-code for a function that is not supported by the device.
Discontinuities of this counter can occur at re-initialization
of the management system, and at other times as indicated by
the value of the ifCounterDiscontinuityTime. "
::= { wwpLeosOamStatsEntry 13 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.4.1.14
wwpLeosOamUnsupportedCodesRx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of OAMPDUs received on this interface
with an unsupported op-code.
An unsupported op-code OAMPDU is indicated by a valid frame
with (1) destination MAC address equal to that of the reserved
MAC address for Slow Protocols (See 43B of [802.3ah]), (2) a
lengthOrType field equal to the reserved type for Slow
Protocols, (3) a Slow Protocols subtype equal to that of the
subtype reserved for OAM, and (4) an OAMPDU code equals the
opcode for a function that is not supported by the device.
Discontinuities of this counter can occur at re-initialization
of the management system, and at other times as indicated by
the value of the ifCounterDiscontinuityTime."
::= { wwpLeosOamStatsEntry 14 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.4.1.15
wwpLeosOamframesLostDueToOam OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of frames that were dropped by the OAM
multiplexer. Since the OAM multiplexer has multiple inputs
and a single output, there may be cases where frames are
dropped due to transmit resource contention. This counter is
incremented whenever a frame is dropped by the OAM layer.
When this counter is incremented, no other counters in this
MIB are incremented.
Discontinuities of this counter can occur at re-initialization
of the management system, and at other times as indicated by
the value of the ifCounterDiscontinuityTime."
::= { wwpLeosOamStatsEntry 15 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.4.1.16
wwpLeosOamStatsPort OBJECT-TYPE
SYNTAX Integer32 (1..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An Ethernet port on the switch"
::= { wwpLeosOamStatsEntry 16 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.4.1.17
wwpLeosOamDuplicateEventNotificationTx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of duplicate Event OAMPDUs transmitted
on this interface. Event notification OAMPDUs may be sent in
duplicate to increase the probability of successfully being
received, given the possibility that a frame may be lost in
transit.
An Event Notification OAMPDU is indicated by a valid frame
with (1) destination MAC address equal to that of the reserved
MAC address for Slow Protocols (See 43B of [802.3ah]), (2) a
lengthOrType field equal to the reserved type for Slow
Protocols, (3) a Slow Protocols subtype equal to that of the
subtype reserved for OAM, and (4) an OAMPDU code equals the
OAM Event code.
A duplicate Event Notification OAMPDU is indicated as an Event
Notification OAMPDU with a Sequence Number field that is
identical to the previously transmitted Event Notification
OAMPDU Sequence Number.
Discontinuities of this counter can occur at re-initialization
of the management system, and at other times as indicated by
the value of the ifCounterDiscontinuityTime."
::= { wwpLeosOamStatsEntry 17 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.4.1.18
wwpLeosOamDuplicateEventNotificationRx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of duplicate Event OAMPDUs received on
this interface. Event notification OAMPDUs may be sent in
duplicate to increase the probability of successfully being
received, given the possibility that a frame may be lost in
transit.
An Event Notification OAMPDU is indicated by a valid frame
with (1) destination MAC address equal to that of the reserved
MAC address for Slow Protocols (See 43B of [802.3ah]), (2) a
lengthOrType field equal to the reserved type for Slow
Protocols, (3) a Slow Protocols subtype equal to that of the
subtype reserved for OAM, and (4) an OAMPDU code equals the
OAM Event code.
A duplicate Event Notification OAMPDU is indicated as an Event
Notification OAMPDU with a Sequence Number field that is
identical to the previously received Event Notification OAMPDU
Sequence Number.
Discontinuities of this counter can occur at re-initialization
of the management system, and at other times as indicated by
the value of the ifCounterDiscontinuityTime. "
::= { wwpLeosOamStatsEntry 18 }
-- 1.3.6.1.4.1.6141.2.60.400.1.2.5
wwpLeosOamSystemEnableDisable OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Global Enable/disable OAM on the switch"
::= { wwpLeosOamObjs 5 }
wwpLeosOamEventConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF WwpLeosOamEventConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Ethernet OAM includes the ability to generate and receive
event notifications to indicate various link problems. This
table contains the mechanisms to configure the thresholds to
generate the standard Ethernet OAM Event.
These events are:
- Errored Symbol Period Event. Generated when the number of
symbol errors exceeds a threshold within a given window
defined by a number of symbols (e.g. 1,000 symbols out of
1,000,000 had errors).
- Errored Frame Period Event. Generated when the number of
frame errors exceeds a threshold within a given window
defined by a number of frames (e.g. 10 frames out of 1000
had errors).
- Errored Frame Event. Generated when the number of frame
errors exceeds a threshold within a given window defined
by a period of time (e.g. 10 frames in 1 second had
errors).
- Errored Frame Seconds Summary Event. Generated when the
number of errored frame seconds exceeds a threshold within
a given time period (e.g. 10 errored frame seconds within
the last 100 seconds). An errored frame second is defined
as a 1 second interval which had >0 frame errors.
"
::= { wwpLeosOamObjs 6 }
-- 1.3.6.1.4.1.6141.2.60.400.1.3.1.1
wwpLeosOamEventConfigEntry OBJECT-TYPE
SYNTAX WwpLeosOamEventConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Event configuration information is available for every
Ethernet like interface that supports OAM and the event
function of OAM as indicated in the wwpLeosOamFunctionsSupported
attribute.
Event configuration controls when the local management entity
sends Event Notification OAMPDUs to its OAM peer. "
INDEX { wwpLeosOamEventPort }
::= { wwpLeosOamEventConfigTable 1 }
WwpLeosOamEventConfigEntry ::=
SEQUENCE {
wwpLeosOamEventPort Integer32,
wwpLeosOamErrFramePeriodWindow Unsigned32,
wwpLeosOamErrFramePeriodThreshold Unsigned32,
wwpLeosOamErrFramePeriodEvNotifEnable INTEGER,
wwpLeosOamErrFrameWindow Unsigned32,
wwpLeosOamErrFrameThreshold Unsigned32,
wwpLeosOamErrFrameEvNotifEnable INTEGER,
wwpLeosOamErrFrameSecsSummaryWindow Integer32,
wwpLeosOamErrFrameSecsSummaryThreshold Integer32,
wwpLeosOamErrFrameSecsEvNotifEnable INTEGER,
wwpLeosOamDyingGaspEnable INTEGER,
wwpLeosOamCriticalEventEnable INTEGER
}
wwpLeosOamEventPort OBJECT-TYPE
SYNTAX Integer32 (1..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An Ethernet port on the switch"
::= { wwpLeosOamEventConfigEntry 1 }
-- 1.3.6.1.4.1.6141.2.60.400.1.3.1.1.1
wwpLeosOamErrFramePeriodWindow OBJECT-TYPE
SYNTAX Unsigned32 (14880..8928000)
UNITS "frames"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of frames over which the threshold is defined.
The default value of the window is the number of minimum size
Ethernet frames that can be received over the physical layer in
one second.
If wwpLeosOamErrFramePeriodThreshold frame errors occur within a
window of wwpLeosOamErrFramePeriodWindow frames, an Event
Notification OAMPDU should be generated with an Errored Frame
Period Event TLV indicating the threshold has been crossed in
this window. "
REFERENCE "[802.3ah], 30.3.6.1.38"
::= { wwpLeosOamEventConfigEntry 2 }
-- 1.3.6.1.4.1.6141.2.60.400.1.3.1.1.2
wwpLeosOamErrFramePeriodThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967293)
UNITS "frames"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of frame errors that must occur for this event to
be triggered. The default value is one frame error.
If wwpLeosOamErrFramePeriodThreshold frame errors occur within a
window of wwpLeosOamErrFramePeriodWindow frames, an Event
Notification OAMPDU should be generated with an Errored Frame
Period Event TLV indicating the threshold has been crossed in
this window. "
REFERENCE "[802.3ah], 30.3.6.1.38"
::= { wwpLeosOamEventConfigEntry 3 }
-- 1.3.6.1.4.1.6141.2.60.400.1.3.1.1.3
wwpLeosOamErrFramePeriodEvNotifEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the occurrence of an Errored Frame Period
Event should result in an Event Notification OAMPDU generated
by the OAM layer.
By default, this object should have the value enabled(1) for
Ethernet like interfaces that support OAM. If the OAM layer
does not support event notifications (as indicated via the
wwpLeosOamFunctionsSupported attribute), this value is ignored. "
::= { wwpLeosOamEventConfigEntry 4 }
-- 1.3.6.1.4.1.6141.2.60.400.1.3.1.1.4
wwpLeosOamErrFrameWindow OBJECT-TYPE
SYNTAX Unsigned32 (10..600)
UNITS "tenths of a second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The amount of time (in 100ms increments) over which the
threshold is defined. The default value is 10 (1 second).
If wwpLeosOamErrFrameThreshold frame errors occur within a window
of wwpLeosOamErrFrameWindow seconds (measured in tenths of
seconds), an Event Notification OAMPDU should be generated with
an Errored Frame Event TLV indicating the threshold has been
crossed in this window. "
REFERENCE "[802.3ah], 30.3.6.1.36"
::= { wwpLeosOamEventConfigEntry 5 }
-- 1.3.6.1.4.1.6141.2.60.400.1.3.1.1.5
wwpLeosOamErrFrameThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967293)
UNITS "frames"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of frame errors that must occur for this event to
be triggered. The default value is one frame error.
If wwpLeosOamErrFrameThreshold frame errors occur within a window
of wwpLeosOamErrFrameWindow (in tenths of seconds), an Event
Notification OAMPDU should be generated with an Errored Frame
Event TLV indicating the threshold has been crossed in this
window. "
REFERENCE "[802.3ah], 30.3.6.1.36"
::= { wwpLeosOamEventConfigEntry 6 }
-- 1.3.6.1.4.1.6141.2.60.400.1.3.1.1.6
wwpLeosOamErrFrameEvNotifEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the occurrence of an Errored Frame Event
should result in an Event Notification OAMPDU generated by the
OAM layer.
By default, this object should have the value enabled(1) for
Ethernet like interfaces that support OAM. If the OAM layer
does not support event notifications (as indicated via the
wwpLeosOamFunctionsSupported attribute), this value is ignored. "
::= { wwpLeosOamEventConfigEntry 7 }
-- 1.3.6.1.4.1.6141.2.60.400.1.3.1.1.7
wwpLeosOamErrFrameSecsSummaryWindow OBJECT-TYPE
SYNTAX Integer32 (100..9000)
UNITS "tenths of a second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The amount of time (in 100ms intervals) over which the
threshold is defined. The default value is 100 (10 seconds).
If wwpLeosOamErrFrameSecsSummaryThreshold frame errors occur
within a window of wwpLeosOamErrFrameSecsSummaryWindow (in tenths
of seconds), an Event Notification OAMPDU should be generated
with an Errored Frame Seconds Summary Event TLV indicating the
threshold has been crossed in this window. "
REFERENCE "[802.3ah], 30.3.6.1.40"
::= { wwpLeosOamEventConfigEntry 8 }
-- 1.3.6.1.4.1.6141.2.60.400.1.3.1.1.8
wwpLeosOamErrFrameSecsSummaryThreshold OBJECT-TYPE
SYNTAX Integer32 (0..65535)
UNITS "errored frame seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of errored frame seconds that must occur for this
event to be triggered. The default value is one errored frame
second.
If wwpLeosOamErrFrameSecsSummaryThreshold frame errors occur
within a window of wwpLeosOamErrFrameSecsSummaryWindow (in tenths
of seconds), an Event Notification OAMPDU should be generated
with an Errored Frame Seconds Summary Event TLV indicating the
threshold has been crossed in this window. "
REFERENCE "[802.3ah], 30.3.6.1.40"
::= { wwpLeosOamEventConfigEntry 9 }
-- 1.3.6.1.4.1.6141.2.60.400.1.3.1.1.9
wwpLeosOamErrFrameSecsEvNotifEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the occurrence of an Errored Frame Seconds
Summary Event should result in an Event Notification OAMPDU
generated by the OAM layer.
By default, this object should have the value enabled(1) for
Ethernet like interfaces that support OAM. If the OAM layer
does not support event notifications (as indicated via the
wwpLeosOamFunctionsSupported attribute), this value is ignored."
::= { wwpLeosOamEventConfigEntry 10 }
-- 1.3.6.1.4.1.6141.2.60.400.1.3.1.1.10
wwpLeosOamDyingGaspEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the local device should attempt to indicate
a dying gasp fault via the OAMPDU flags field to its peer OAM
entity. If the system does not support dying gasp capability,
setting this object has no effect, and reading the object
should always result in 'disabled(2)'.
By default, this object should have the value enabled(1) for
Ethernet like interfaces that support OAM. If the OAM layer
does not support event notifications (as indicated via the
OamFunctionsSupported attribute), this value is ignored."
::= { wwpLeosOamEventConfigEntry 11 }
-- 1.3.6.1.4.1.6141.2.60.400.1.3.1.1.11
wwpLeosOamCriticalEventEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the local device should attempt to indicate
a critical event has occurred via the OAMPDU flags field to its peer OAM
entity. If the system does not support dying gasp capability,
setting this object has no effect, and reading the object
should always result in 'disabled(2)'.
By default, this object should have the value enabled(1) for
Ethernet like interfaces that support OAM. If the OAM layer
does not support event notifications (as indicated via the
OamFunctionsSupported attribute), this value is ignored."
::= { wwpLeosOamEventConfigEntry 12 }
-- 1.3.6.1.4.1.6141.2.60.400.1.3.2
wwpLeosOamEventLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF WwpLeosOamEventLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table records a history of the events that have occurred
at the Ethernet OAM level. These events can include locally
detected events, which may result in locally generated
OAMPDUs, and remotely detected events, which are detected by
the OAM peer entity and signaled to the local entity via
Ethernet OAM. Ethernet OAM events can be signaled by Event
Notification OAMPDUs or by the flags field in any OAMPDU. "
::= { wwpLeosOamObjs 7 }
-- 1.3.6.1.4.1.6141.2.60.400.1.3.2.1
wwpLeosOamEventLogEntry OBJECT-TYPE
SYNTAX WwpLeosOamEventLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the wwpLeosOamEventLogTable."
INDEX { wwpLeosOamEventLogPort, wwpLeosOamEventLogIndex }
::= { wwpLeosOamEventLogTable 1 }
WwpLeosOamEventLogEntry ::=
SEQUENCE {
wwpLeosOamEventLogPort Integer32,
wwpLeosOamEventLogIndex Unsigned32,
wwpLeosOamEventLogTimestamp TimeStamp,
wwpLeosOamEventLogOui OCTET STRING,
wwpLeosOamEventLogType Unsigned32,
wwpLeosOamEventLogLocation INTEGER,
wwpLeosOamEventLogWindowHi Unsigned32,
wwpLeosOamEventLogWindowLo Unsigned32,
wwpLeosOamEventLogThresholdHi Unsigned32,
wwpLeosOamEventLogThresholdLo Unsigned32,
wwpLeosOamEventLogValue Counter64,
wwpLeosOamEventLogRunningTotal Counter64,
wwpLeosOamEventLogEventTotal Unsigned32
}
wwpLeosOamEventLogPort OBJECT-TYPE
SYNTAX Integer32 (1..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An Ethernet port on the switch"
::= { wwpLeosOamEventLogEntry 1 }
wwpLeosOamEventLogIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An arbitrary integer for identifying individual events
within the event log. "
::= { wwpLeosOamEventLogEntry 2 }
wwpLeosOamEventLogTimestamp OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time of the logged event. For
locally generated events, the time of the event can be
accurately retrieved from sysUpTime. For remotely generated
events, the time of the event is indicated by the reception of
the Event Notification OAMPDU indicating the event occurred on
the peer. A system may attempt to adjust the timestamp value
to more accurately reflect the time of the event at the peer
OAM entity by using other information, such as that found in
the timestamp found of the Event Notification TLVs, which
provides an indication of the relative time between events at
the peer entity. "
::= { wwpLeosOamEventLogEntry 3 }
wwpLeosOamEventLogOui OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(3))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The OUI of the entity defining the object type. All IEEE
802.3 defined events (as appearing in [802.3ah] except for the
Organizationally Unique Event TLVs) use the IEEE 802.3 OUI of
0x0180C2. Organizations defining their own Event Notification
TLVs include their OUI in the Event Notification TLV which
gets reflected here. "
::= { wwpLeosOamEventLogEntry 4 }
wwpLeosOamEventLogType OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of event that generated this entry in the event log.
When the OUI is the IEEE 802.3 OUI of 0x0180C2, the following
event types are defined:
erroredSymbolEvent(1),
erroredFramePeriodEvent (2),
erroredFrameEvent(3),
erroredFrameSecondsEvent(4),
linkFault(256),
dyingGaspEvent(257),
criticalLinkEvent(258)
The first four are considered threshold crossing events as
they are generated when a metric exceeds a given value within
a specified window. The other three are not threshold
crossing events.
When the OUI is not 0x0180C2, then some other organization has
defined the event space. If event subtyping is known to the
implementation, it may be reflected here. Otherwise, this
value should return all F's (0xFFFFFFFF).
"
REFERENCE "[802.3ah], 30.3.6.1.10 and 57.5.3."
::= { wwpLeosOamEventLogEntry 5 }
wwpLeosOamEventLogLocation OBJECT-TYPE
SYNTAX INTEGER { local(1), remote(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Whether this event occurred locally, or was received from the
OAM peer via Ethernet OAM."
::= { wwpLeosOamEventLogEntry 6 }
wwpLeosOamEventLogWindowHi OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the event represents a threshold crossing event, the two
objects wwpLeosOamEventWindowHi and wwpLeosOamEventWindowLo form an
unsigned 64-bit integer yielding the window over which the
value was measured for the threshold crossing event (e.g. 5,
when 11 occurrences happened in 5 seconds while the threshold
was 10). The two objects are combined as:
wwpLeosOamEventLogWindow = ((2^32) * wwpLeosOamEventLogWindowHi)
+ wwpLeosOamEventLogWindowLo
Otherwise, this value is returned as all F's (0xFFFFFFFF) and
adds no useful information. "
REFERENCE "[802.3ah], 30.3.6.1.37 and 57.5.3.2."
::= { wwpLeosOamEventLogEntry 7 }
wwpLeosOamEventLogWindowLo OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the event represents a threshold crossing event, the two
objects wwpLeosOamEventWindowHi and wwpLeosOamEventWindowLo form an
unsigned 64-bit integer yielding the window over which the
value was measured for the threshold crossing event (e.g. 5,
when 11 occurrences happened in 5 seconds while the threshold
was 10). The two objects are combined as:
wwpLeosOamEventLogWindow = ((2^32) * wwpLeosOamEventLogWindowHi)
+ wwpLeosOamEventLogWindowLo
Otherwise, this value is returned as all F's (0xFFFFFFFF) and
adds no useful information. "
REFERENCE "[802.3ah], 30.3.6.1.37 and 57.5.3.2."
::= { wwpLeosOamEventLogEntry 8 }
wwpLeosOamEventLogThresholdHi OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the event represents a threshold crossing event, the two
objects wwpLeosOamEventThresholdHi and wwpLeosOamEventThresholdLo
form an unsigned 64-bit integer yielding the value that was
crossed for the threshold crossing event (e.g. 10, when 11
occurrences happened in 5 seconds while the threshold was 10).
The two objects are combined as:
wwpLeosOamEventLogThreshold = ((2^32) * wwpLeosOamEventLogThresholdHi)
+ wwpLeosOamEventLogThresholdLo
Otherwise, this value is returned as all F's (0xFFFFFFFF) and
adds no useful information. "
REFERENCE "[802.3ah], 30.3.6.1.37 and 57.5.3.2."
::= { wwpLeosOamEventLogEntry 9 }
-- 1.3.6.1.4.1.6141.2.400.1.2.7.1.10
wwpLeosOamEventLogThresholdLo OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the event represents a threshold crossing event, the two
objects wwpLeosOamEventThresholdHi and wwpLeosOamEventThresholdLo
form an unsigned 64-bit integer yielding the value that was
crossed for the threshold crossing event (e.g. 10, when 11
occurrences happened in 5 seconds while the threshold was 10).
The two objects are combined as:
wwpLeosOamEventLogThreshold = ((2^32) * wwpLeosOamEventLogThresholdHi)
+ wwpLeosOamEventLogThresholdLo
Otherwise, this value is returned as all F's (0xFFFFFFFF) and
adds no useful information. "
REFERENCE "[802.3ah], 30.3.6.1.37 and 57.5.3.2."
::= { wwpLeosOamEventLogEntry 10 }
wwpLeosOamEventLogValue OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the event represents a threshold crossing event, this
value indicates the value of the parameter within the given
window that generated this event (e.g. 11, when 11 occurrences
happened in 5 seconds while the threshold was 10).
Otherwise, this value is returned as all F's
(0xFFFFFFFFFFFFFFFF) and adds no useful information.
"
REFERENCE "[802.3ah], 30.3.6.1.37 and 57.5.3.2."
::= { wwpLeosOamEventLogEntry 11 }
wwpLeosOamEventLogRunningTotal OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value represents the total number of times this
occurrence has happened since the last reset (e.g. 3253, when
3253 symbol errors have occurred since the last reset, which
has resulted in 51 symbol error threshold crossing events
since the last reset). "
REFERENCE "[802.3ah], 30.3.6.1.37 and 57.5.3.2."
::= { wwpLeosOamEventLogEntry 12 }
wwpLeosOamEventLogEventTotal OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value represents the total number of times one or more
of these occurrences have resulted in an event (e.g. 51 when
3253 symbol errors have occurred since the last reset, which
has resulted in 51 symbol error threshold crossing events
since the last reset)."
REFERENCE "[802.3ah], 30.3.6.1.37 and 57.5.3.2."
::= { wwpLeosOamEventLogEntry 13 }
--
-- OAM Global Attributes
--
wwpLeosOamGlobal OBJECT IDENTIFIER ::= { wwpLeosOamObjs 8 }
wwpLeosOamStatsClear OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'true' will cause the values of all objects maintained within the wwpLeosOamStatsTable to reset to the value of zero.
When read, this object always returns the value of false."
::= { wwpLeosOamGlobal 1 }
--
-- Notifications
--
wwpLeosOamNotifMIBNotificationPrefix OBJECT IDENTIFIER ::= { wwpLeosOamMIB 3 }
wwpLeosOamNotifMIBNotification OBJECT IDENTIFIER ::= { wwpLeosOamNotifMIBNotificationPrefix 0 }
wwpLeosOamLinkEventTrap NOTIFICATION-TYPE
OBJECTS {
wwpLeosOamEventLogPort,
wwpLeosOamEventLogType,
wwpLeosOamEventLogLocation
}
STATUS current
DESCRIPTION "A wwpLeosOamLinkEventTrap notification is sent whenever a local or
remote link event is detected and recorded in the wwpLeosOamEventLogTable."
::= { wwpLeosOamNotifMIBNotification 1 }
wwpLeosOamLinkLostTimerActiveTrap NOTIFICATION-TYPE
OBJECTS {
wwpLeosOamPort,
wwpLeosEtherPortDesc,
wwpLeosEtherPortOperStatus,
wwpLeosOamOperStatus,
wwpLeosOamPeerStatus,
wwpLeosOamPeerMacAddress
}
STATUS current
DESCRIPTION "A wwpLeowsOamLinkLostTimerActiveTrap notification is sent whenever a
link lost timer becomes active for a port."
::= { wwpLeosOamNotifMIBNotification 2 }
wwpLeosOamLinkLostTimerExpiredTrap NOTIFICATION-TYPE
OBJECTS {
wwpLeosOamPort,
wwpLeosEtherPortDesc,
wwpLeosEtherPortOperStatus,
wwpLeosOamOperStatus,
wwpLeosOamPeerStatus,
wwpLeosOamPeerMacAddress
}
STATUS current
DESCRIPTION "A wwpLeowsOamLinkLostTimerActiveTrap notification is sent whenever a
link lost timer expires for a port."
::= { wwpLeosOamNotifMIBNotification 3 }
END
--
-- WWP-LEOS-OAM-MIB.my
--