Observium_CE/mibs/ciena/WWP-APPLICATIONS-MIB

240 lines
6.2 KiB
Plaintext

--
-- WWP-APPLICAIONS-MIB.my
--
--
WWP-APPLICATIONS-MIB DEFINITIONS ::= BEGIN
IMPORTS
IpAddress, Integer32, OBJECT-TYPE, MODULE-IDENTITY
FROM SNMPv2-SMI
DisplayString, RowStatus
FROM SNMPv2-TC
wwpModules
FROM WWP-SMI;
wwpApplicationsMIB MODULE-IDENTITY
LAST-UPDATED "200104031700Z"
ORGANIZATION "World Wide Packets, Inc"
CONTACT-INFO
" Mib Meister
Postal: World Wide Packets
P.O. Box 950
Veradale, WA 99037
USA
Phone: +1 509 242 9000
Email: mib.meister@worldwidepackets.com"
DESCRIPTION
"The MIB module for the WWP Applications specific information."
REVISION "200104031700Z"
DESCRIPTION
"Initial creation."
::= { wwpModules 6 }
--
-- Node definitions
--
wwpApplicationsMIBObjects OBJECT IDENTIFIER ::= { wwpApplicationsMIB 1 }
wwpWeb OBJECT IDENTIFIER ::= { wwpApplicationsMIBObjects 2 }
wwpTelnet OBJECT IDENTIFIER ::= { wwpApplicationsMIBObjects 3 }
wwpDns OBJECT IDENTIFIER ::= { wwpApplicationsMIBObjects 4 }
wwpLog OBJECT IDENTIFIER ::= { wwpApplicationsMIBObjects 5 }
-- Notifications
wwpApplicationsMIBNotificationPrefix OBJECT IDENTIFIER ::= { wwpApplicationsMIB 2 }
wwpApplicationsMIBNotifications OBJECT IDENTIFIER ::=
{ wwpApplicationsMIBNotificationPrefix 0 }
-- Conformance information
wwpApplicationsMIBConformance OBJECT IDENTIFIER ::= { wwpApplicationsMIB 3 }
wwpApplicationsMIBCompliances OBJECT IDENTIFIER ::= { wwpApplicationsMIBConformance 1 }
wwpApplicationsMIBGroups OBJECT IDENTIFIER ::= { wwpApplicationsMIBConformance 2 }
wwpWebEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables or disables device mgt via the web."
DEFVAL { enable }
::= { wwpWeb 1 }
wwpWebMaxLogins OBJECT-TYPE
SYNTAX Integer32 (0..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the maximum number of users the can be logged
into the web server."
DEFVAL { 5 }
::= { wwpWeb 2 }
wwpWebInactivityTimeout OBJECT-TYPE
SYNTAX Integer32 (0..3600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the period in seconds after which the user will
be logged off if no activiy has taken place."
DEFVAL { 60 }
::= { wwpWeb 3 }
--
-- Telnet Application
--
wwpTelnetEnableServer OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables users to connect to the device via Telnet."
DEFVAL { enable }
::= { wwpTelnet 1 }
wwpTelnetMaxConnections OBJECT-TYPE
SYNTAX Integer32 (0..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the maximum number of telnet sessions that can
be active at any given time."
::= { wwpTelnet 2 }
wwpTelnetTimeout OBJECT-TYPE
SYNTAX Integer32 (0..1800)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the time in seconds after which the user will
be logged out if no activity is detected."
DEFVAL { 300 }
::= { wwpTelnet 3 }
wwpTelnetEnableClient OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether the user is able to telnet out
of the device to any other telnet server accessible
on the network."
DEFVAL { enable }
::= { wwpTelnet 4 }
wwpDnsEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables or disables the DNS support."
DEFVAL { enable }
::= { wwpDns 1 }
wwpDnsDomainName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DNS domain name."
::= { wwpDns 2 }
wwpDnsServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF WwpDnsServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of DNS servers."
::= { wwpDns 3 }
wwpDnsServerEntry OBJECT-TYPE
SYNTAX WwpDnsServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DNS server entry."
INDEX { wwpDnsServerIpAddr }
::= { wwpDnsServerTable 1 }
WwpDnsServerEntry ::= SEQUENCE {
wwpDnsServerIpAddr IpAddress,
wwpDnsServerPrimary INTEGER,
wwpDnsServerRowStatus RowStatus
}
wwpDnsServerIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DNS server IP address."
::= { wwpDnsServerEntry 1 }
wwpDnsServerPrimary OBJECT-TYPE
SYNTAX INTEGER {
primary(1),
secondary(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether this is the primary or secondary
DNS server. The system will first attempt the primary
DNS server, if not successful, it will attempt
others in the list. Only one primary dns server
may be specified."
::= { wwpDnsServerEntry 2 }
wwpDnsServerRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"To create a row in this table, a manager must
set this object to either createAndGo(4)."
::= { wwpDnsServerEntry 3 }
wwpLogServerAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The address of the wwpLogserver. At this moment we can just
have one server."
::= { wwpLog 1 }
wwpLogServerPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The log port for the wwpLogserver."
::= { wwpLog 2 }
END
--
-- WWP-APPLICATIONS-MIB
--