Observium_CE/mibs/cabletron/Cabletron-MIB

4541 lines
92 KiB
Plaintext

--
-- Cabletron Management Information Base
-- For the MMAC Intelligent Repeater (IRBM & IRM2)
-- By: Howard Brown
-- Rev: 1.2
-- Date: July 20, 1991
--
-- NOTE: Not all devices support all objects
--
-- REVISION HISTORY
--
-- Rev. 0.1 - Initial REV.
--
-- Rev. 0.2 - Revised to simplify and reflect IRM
--
-- Rev. 0.3 - Revised and updated.
-- (1) Changed Errors to Collisions where appropriate.
-- (2) Removed the redundant entries
-- (3) Renumbered boards to reflect reality
-- (4) Renamed err_limit to alarm_limit to reflect proper
-- use.
--
-- Rev. 0.4 - Revised and updated. Now fully reflects IRBM, IRM
-- MIB seperated.
-- (1) Added topological port types
-- (2) Added statistics by topological port type.
-- (3) Spread port status to 3 variables ( admin, link,
-- network)
-- (4) Added source address support
-- (5) Added Redundancy
-- (6) Added SNMP controlled device discovery
-- (7) Moved Alarm control to its own section of the MIB.
-- (8) Redefined alarms
-- (9) Defined TRAP types
--
-- Rev. 0.5 - Reflects the IRBM as of release 0.0.1
--
-- Rev. 0.5a - Working version - Reflects as built for 0.0.4
--
-- Rev. 0.6 - Reflects the IRBM as of 0.1.1
-- Formal description of the Cabletron MIB
--
-- Rev 1.0 - Reflects the IRBM, IRM2, MRXI, and MiniMMAC products as
-- of their first customer ship (NOT BETA)
-- Put into concise format and run thru the Mosy compiler
-- Rev 1.1 - Fixed the first round of bugs
-- (1) Added missing token ring based objects to RepeaterRev2.device
-- (2) Added the PC card variable
-- (3) fixed typos
-- (4) added more complete definition of RepeaterRev2 tree
--
-- Rev 1.2 - Removed the duplicate names
--
Cabletron-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises, Counter FROM RFC1155-SMI
OBJECT-TYPE, IpAddress FROM SNMPv2-SMI;
cabletron OBJECT IDENTIFIER ::= { enterprises 52 }
commsDevice OBJECT IDENTIFIER ::= { cabletron 1 }
layerMgmt OBJECT IDENTIFIER ::= { cabletron 2 }
common OBJECT IDENTIFIER ::= { commsDevice 1 }
repeater OBJECT IDENTIFIER ::= { commsDevice 2 }
bridge OBJECT IDENTIFIER ::= { commsDevice 3 }
router OBJECT IDENTIFIER ::= { commsDevice 4 }
product OBJECT IDENTIFIER ::= { commsDevice 5 }
subsystem OBJECT IDENTIFIER ::= { commsDevice 6 }
commonRev1 OBJECT IDENTIFIER ::= { common 1 }
sysOIDs OBJECT IDENTIFIER ::= { common 2 }
repeaterRev1 OBJECT IDENTIFIER ::= { repeater 1 }
repeaterRev2 OBJECT IDENTIFIER ::= { repeater 2 }
-- Common MIB Structure
-- ---------------------
--
-- The Common MIB is a group of objects that are common to
-- all communications devices. This section will describe these
-- objects.
--
-- Instance Identifiers for Common objects
-- ----------------------------------------
--
-- There is only one instance of an Common object in any
-- device. Thus the Instance Identifier is 0.
deviceType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object defines the board type for the Management
board in the device. (eg. IRBM, IRM). See appendix A for
value."
::= { commonRev1 1 }
deviceName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"An ASCII name of the device that this agent manages."
::= { commonRev1 2 }
deviceIPAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Internet address of this device."
::= { commonRev1 3 }
currentTime OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The current time of day as measured by the device"
::= { commonRev1 4 }
currentDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Character representation of the current date"
::= { commonRev1 5 }
mACAddress OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC (Ethernet) address of the MMAC. This
can also be obtained from address translation MIB. The
Instance Identifier for the MAC address is interface
number. For the IRBM, their are 2."
::= { commonRev1 6 }
-- SysOIDs definitions
--
-- This section defines the values returned by the System OID
-- in the Internet MIB. These are NOT objects in the MIB but
-- come from the OID tree assigned to Cabletron.
--
--
-- Formal Definitions
sysOtherType OBJECT IDENTIFIER ::= { sysOIDs 1 }
-- All devices that do not fit into the following classes
--
sysIRMType OBJECT IDENTIFIER ::= { sysOIDs 2 }
-- All devices that fit into the IRM slot of an MMAC
sysRepType OBJECT IDENTIFIER ::= { sysOIDs 3 }
-- All standalone Repeater devices
sysBDGType OBJECT IDENTIFIER ::= { sysOIDs 4 }
-- All standalone bridges
-- sysIRM Object Identifiers
soidIRMSNMP OBJECT IDENTIFIER ::= { sysIRMType 1 }
soidIRBM OBJECT IDENTIFIER ::= { sysIRMType 2 }
soidIRM2 OBJECT IDENTIFIER ::= { sysIRMType 3 }
-- sysRepType Object identifiers
soidMINIMMAC OBJECT IDENTIFIER ::= { sysRepType 1 }
soidMRXI OBJECT IDENTIFIER ::= { sysRepType 2 }
-- Formal definitions for RepeaterRev1
device OBJECT IDENTIFIER ::= { repeaterRev1 1 }
board OBJECT IDENTIFIER ::= { repeaterRev1 2 }
port OBJECT IDENTIFIER ::= { repeaterRev1 3 }
sourceAddr OBJECT IDENTIFIER ::= { repeaterRev1 7 }
redundancy OBJECT IDENTIFIER ::= { repeaterRev1 8 }
alarm OBJECT IDENTIFIER ::= { repeaterRev1 9 }
-- device Object Definitions
--
-- This section defines the objects under the Device node.
--
-- Instance Identifiers for device objects
--
-- Again there is only one instance of an device object in
-- any device. Thus the Instance Identifier is 0.
--
-- device Objects
deviceMMACType OBJECT-TYPE
SYNTAX INTEGER
{
mMAC8(0),
mMAC3(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the type of MMAC."
::= { device 2 }
deviceSlots OBJECT-TYPE
SYNTAX INTEGER
{
mMAC8(8),
mMAC3(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of available device slots in this device,
including the IRM slot."
::= { device 3 }
deviceOccupiedSlots OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slots that contain MIM boards.
This field is bit encoded (eg. If a bit is set then
that board is present. For example, a value of 3 indicates
that there are boards in the IRM slot and the first MIM
slot."
::= { device 4 }
devicePortsOn OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of operating ports on the device."
::= { device 5 }
deviceTotalPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of repeater ports on the MMAC."
::= { device 6 }
deviceTotalPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets detected on all ports of this
device."
::= { device 7 }
deviceTotalErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sum of all of the errors listed including
alignment,CRC, runts, giants, and Out of window
collisions."
::= { device 8 }
deviceTransmitColl OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of transmit collisions detected by this
MMAC."
::= { device 9 }
deviceRecColls OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of receive collsions detected by this MMAC."
::= { device 10 }
deviceAlign OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of packets with alignement errors detected.
"
::= { device 11 }
deviceCRC OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of packets with bad CRC detected. "
::= { device 12 }
deviceRunt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of runt frames detected by this device."
::= { device 13 }
deviceOOWColl OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of out-of-window collisions detected by this"
::= { device 14 }
deviceNoResources OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of No resource condtions detected."
::= { device 15 }
deviceRecBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of bytes detected on the network."
::= { device 16 }
deviceGiantFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of longer than 1518 bytes."
::= { device 17 }
deviceRestart OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If this object is set to 0 the device is restarted."
::= { device 18 }
deviceResetCounter OBJECT-TYPE
SYNTAX Counter
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If this object is set to 0, all of the devices Counters
are reset to 0."
::= { device 19 }
deviceRedundantCts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of redundant circuits available for use."
::= { device 20 }
deviceTimeBase OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of seconds used as the interval for
performing all of the rate alarm checks. The minimum is 10
secs."
::= { device 24 }
deviceResetRedundancy OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this object to a 1 will reset redundancy for the
entire box."
::= { device 25 }
deviceSrcAddrAgingTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of minutes that a source address is not detected before
it is removed from the source address table."
::= { device 26 }
deviceSrcAddrTraps OBJECT-TYPE
SYNTAX INTEGER
{
trapsoff(1),
trapson(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls sending of source address related traps."
::= { device 27 }
deviceSrcAddrLocked OBJECT-TYPE
SYNTAX INTEGER
{
lockoff(1),
lockon(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If this is set to 2, any source addresses
that are detected on station ports that are not in the table
will cause the port to be turned off."
::= { device 28 }
deviceEnetBoardMap OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slots that contain Ethernet MIM boards."
-- This field is bit encoded (e.g. If a bit is set then that board
-- is present and is an Ethernet MIM.) For example, a value of 3 indicates
-- that there are boards in the IRM slot and the first MIM slot and that
-- these boards are Ethernet MIMs.
::= { device 29 }
deviceTokenRingBoardMap OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slots that contain Token Ring MIM boards."
-- This field is bit encoded (e.g. If a bit is set then that board
-- is present and is a Token Ring MIM.) For example, a value of 2 indicates
-- that there is a board in the first MIM slot and the board is a Token Ring
-- MIM.
::= { device 30 }
deviceFDDIBoardMap OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slots that contain FDDI MIM boards."
-- This field is bit encoded (e.g. If a bit is set then that board
-- is present and is a FDDI MIM.) For example, a value of 2 indicates
-- that there is a board in the first MIM slot and the board is a FDDI
-- MIM.
::= { device 31 }
-- sourceAddr object definitions
--
-- The sourceAddr object section contains objects that can
-- be accessed by source address.
--
-- Instance Identifier for sourceAddr objects
--
-- The instance identifier for these variables is the
-- source address the user is interested in. Each octet of the
-- source address forms a term in the instance identifier (see
-- below)
sourceAddrBoard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The board number of the port that the supplied source
address has been found on."
::= { sourceAddr 1 }
sourceAddrPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port number of the port that the supplied source
address has been found on."
::= { sourceAddr 2 }
-- redundancy Object Definitions
--
-- This section defines the objects that are associated
-- with cable level redundancy. The concepts for this are
-- described in other documentation. It should be noted here
-- that the port specific objects for redundancy can be found
-- in the PORT section of the MIB.
-- The maximum number of redundant circuits can be found in the
-- DEVICE section of the MIB.
--
-- Instance Identifiers for redundancy Objects
--
-- There are two types of instance identifiers for
-- redundancy objects. First, are the global objects that apply
-- to all redundant circuits. These have an instance identifier
-- of 0. The second kind of object is circuit specific, the
-- instance identifier for these is the circuit number.
redundancyPollInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of seconds between polls for redundancy."
::= { redundancy 1 }
redundancyTestTod OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time of day at which the redundant circuits should be tested."
::= { redundancy 2 }
redundancyPerformTest OBJECT-TYPE
SYNTAX INTEGER
{
performTest(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Test the redundant circuit."
::= { redundancy 3 }
redundancyCircuitName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name of the indicated circuit."
::= { redundancy 4 }
redundancyRetryCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of unanswered polls allowed for the indicated
circuit before the current connection is declared bad."
::= { redundancy 5 }
redundancyNumBPs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of board/port combinations associated with the
indicated circuit."
::= { redundancy 6 }
redundancyCircuitBoards OBJECT-TYPE
-- Note:The instance identifier for this object is the circuit
-- number followed by an index. The index has no other meaning
-- than to be used as an index for the purposes of the GET NEXT
-- operation.
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The boards associated with the indicated circuit, accessed by index."
::= { redundancy 7 }
redundancyCircuitPort OBJECT-TYPE
-- Note:The instance identifier for this object is the circuit
-- number followed by an index. The index has no other meaning
-- than to be used as an index for the purposes of the GET NEXT
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ports associated with the indicated circuit, accessed by index."
::= { redundancy 8 }
redundancyCircuitTypes OBJECT-TYPE
-- Note:The instance identifier for this object is the circuit
-- number followed by an index. The index has no other meaning
-- than to be used as an index for the purposes of the GET NEXT
-- operation.
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of each port associated with the indicated circuit,
accessed by index."
::= { redundancy 9 }
redundancyCircuitNumAddr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of addresses associated with the indicated circuit."
::= { redundancy 10 }
redundancyCircuitMACAddrAdd OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Adds the ethernet address to the polling list for the
indicated circuit."
::= { redundancy 11 }
redundancyCircuitMACAddrDel OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Removes the ethernet address from the polling list for the
indicated circuit."
::= { redundancy 12 }
redundancyCircuitMACAddrDisp OBJECT-TYPE
-- Note:The instance identifier for this object is the circuit
-- number followed by an index. The index has no other meaning
-- than to be used as an index for the purposes of the GET NEXT
-- operation.
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ethernet addresses associated with the indicated circuit,
accessed by index."
::= { redundancy 13 }
redundancyCircuitEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enables and disables the indicated circuit."
::= { redundancy 14 }
redundancyCircuitReset OBJECT-TYPE
SYNTAX INTEGER
{
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset the indicated circuit. Return all of the associated
board and ports to NOT-USED, remove associated addresses
from the polling list, reset the circuit name and retry
count to default values ."
::= { redundancy 15 }
-- alarm Object definitions
--
-- This section defines the objects that can cause alarms
-- to be generated. All of the alarm objects presented are
-- objects that derive there values from other parts of the MIB
-- and hence the structure of this section of the MIB mirrors
-- the sections that generate the raw data.
--
-- For each section there are 3 sources of alarms:Traffic
-- levels, collsion rates (as they relate to traffic), and
-- error rates (also related to traffic). All alarms are
-- qualified by the Devicetimebase (ie. the rates are measured
-- for a particular length of time).
--
-- Formal defintions for the structure below alarm
devAlrm OBJECT IDENTIFIER ::= { alarm 1 }
bdAlrm OBJECT IDENTIFIER ::= { alarm 2 }
portAlrm OBJECT IDENTIFIER ::= { alarm 3 }
-- devAlrm object defintions
--
-- This section defines the objects that will control
-- alarms associated with the device.
--
-- devAlrm Instance Identifiers
-- There is only one set of device level alarms per MMAC
-- thus the instance identifiers for DevAlrm objects is 0.
--
-- Formal defintions below devAlrm
devTraffic OBJECT IDENTIFIER ::= { devAlrm 1 }
devColls OBJECT IDENTIFIER ::= { devAlrm 2 }
devError OBJECT IDENTIFIER ::= { devAlrm 3 }
-- devTraffic Object Definitions
--
-- This section define the devTraffic objects. These
-- objects control the device level traffic alarm generation.
devTrafficEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable the sending of device level traffic traps."
::= { devTraffic 1 }
devTrafficThreshold OBJECT-TYPE
SYNTAX Counter
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The threshold of packets within the
devicetimebase that will cause a traffic alarm."
::= { devTraffic 2 }
-- devColls Object Defintions
--
-- This section defines the objects that control the
-- device level collision alarm.
devCollsEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable the sending of device level collsion alarms."
::= { devColls 1 }
devCollsThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object represents the number of collisions per
good packet measured by the device that will generate
an alarm. valid values are 1 to 15"
::= { devColls 2 }
-- devErrorS Object Defintions
--
-- This section defines the objects that control the
-- device level error alarm.
devErrorEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable the sending of device level error alarms."
::= { devError 1 }
devErrorThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object represents the percentage of errors per
good packet that will generate an alarm."
::= { devError 2 }
devErrorSource OBJECT-TYPE
SYNTAX INTEGER
-- The INTEGER is a bit encoded version of which errors to
-- include in the error sum. The bits are encoded as follows:
-- CRC_errors - Bit 0 - Least Significant Bit
-- runts - Bit 1
-- OOW_colls - Bit 2
-- align_errs - Bit 3
-- No_resource - Bit 4
-- Giants - Bit 5
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The type of error used for the error alarm."
::= { devError 3 }
-- bdAlrm object defintions
--
-- This section defines the objects that will control
-- alarms associated with the board.
--
-- bdAlrm Instance Identifiers
--
--
-- There is set of board level alarms per board thus the
-- instance identifiers for bdAlrm objects is teh board number.
--
-- Formal defintions below bdAlrm
bdTraffic OBJECT IDENTIFIER ::= { bdAlrm 1 }
bdColls OBJECT IDENTIFIER ::= { bdAlrm 2 }
bdError OBJECT IDENTIFIER ::= { bdAlrm 3 }
-- bdTraffic Object Definitions
--
--
-- This section define the bdTraffic objects. These
-- objects control the board level traffic alarm generation.
bdTrafficEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable the sending of board level traffic traps for
this board."
::= { bdTraffic 1 }
bdTrafficThreshold OBJECT-TYPE
SYNTAX Counter
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The threshold of packets within the Devicetimebase that
will cause a traffic alarm."
::= { bdTraffic 2 }
-- bdColls Object Defintions
--
-- This section defines the objects that control the board
-- level collision alarm.
bdCollsEnable OBJECT-TYPE
SYNTAX INTEGER
{ disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable the sending of board level collsion alarms."
::= { bdColls 1 }
bdCollsThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object represents the number of collisions per
good packet measured by the board that will generate an
alarm. valid values are 1 to 15"
::= { bdColls 2 }
-- bdErrorS Object Defintions
--
-- This section defines the objects that control the board
-- level error alarm.
bdErrorEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable the sending of board level error alarms."
::= { bdError 1 }
bdErrorThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object represents the percentage of errors per
good packet that will generate an alarm."
::= { bdError 2 }
bdErrorSource OBJECT-TYPE
SYNTAX INTEGER
-- The INTEGER is a bit encoded version of which errors to
-- include in the error sum. The bits are encoded as follows:
--
-- CRC_errors - Bit 0 - Least Significant Bit
-- runts - Bit 1
-- OOW_colls - Bit 2
-- align_errs - Bit 3
-- No_resource - Bit 4
-- Giants - Bit 5
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The type of error used for the error alarm."
::= { bdError 3 }
-- portAlrm object defintions
--
-- This section defines the objects that will control
-- alarms associated with the port.
--
-- portAlrm Instance Identifiers
--
-- There is set of port level alarms per board thus the
-- instance identifiers for portAlrm objects is teh board
-- number.
--
-- Formal defintions below portAlrm
--
portTraffic OBJECT IDENTIFIER ::= { portAlrm 1 }
portColls OBJECT IDENTIFIER ::= { portAlrm 2 }
portError OBJECT IDENTIFIER ::= { portAlrm 3 }
-- portTraffic Object Definitions
--
-- This section define the portTraffic objects. These
-- objects control the port level traffic alarm generation.
--
portTrafficEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable the sending of port level traffic traps for this
port."
::= { portTraffic 1 }
portTrafficThreshold OBJECT-TYPE
SYNTAX Counter
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The threshold of packets within the Devicetimebase that
will cause a traffic alarm."
::= { portTraffic 2 }
-- portColls Object Defintions
--
-- This section defines the objects that control the port
-- level collision alarm.
--
portCollsEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable the sending of port level collsion alarms."
::= { portColls 1 }
portCollsThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object represents the number of collisions per
good packet measured by the port that will generate an
alarm."
::= { portColls 2 }
-- portErrorS Object Defintions
--
-- This section defines the objects that control the port
-- level error alarm.
portErrorEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable the sending of port level error alarms."
::= { portError 1 }
portErrorThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object represents the percentage of errors per
good packet that will generate an alarm."
::= { portError 2 }
portErrorSource OBJECT-TYPE
SYNTAX INTEGER
-- The INTEGER is a bit encoded version of which errors to
-- include in the error sum. The bits are encoded as follows:
-- CRC_errors - Bit 0 - Least Significant Bit
-- runts - Bit 1
-- OOW_colls - Bit 2
-- align_errs - Bit 3
-- No_resource - Bit 4
-- Giants - Bit 5
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The type of error used for the error alarm."
::= { portError 3 }
-- RepeaterRev2 Formal declarations
rr2device OBJECT IDENTIFIER ::= { repeaterRev2 1 }
network OBJECT IDENTIFIER ::= { repeaterRev2 2 }
rr2board OBJECT IDENTIFIER ::= { repeaterRev2 3 }
rr2port OBJECT IDENTIFIER ::= { repeaterRev2 4 }
repeaterTables OBJECT IDENTIFIER ::= { repeaterRev2 5 }
commonD OBJECT IDENTIFIER ::= { rr2device 1 }
ethernetD OBJECT IDENTIFIER ::= { rr2device 2 }
tokenRingD OBJECT IDENTIFIER ::= { rr2device 3 }
deviceTRTokenRingPortsOn OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Token Ring Ports (i.e. station, Ring In and
Ring Out ports) enabled on this device."
::= { tokenRingD 1 }
deviceTRTotalTokenRingPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of Token Ring Ports (i.e. station, Ring In and
Ring Out ports) on this device."
::= { tokenRingD 2 }
deviceTRTotalTokenRingRingPortsOn OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of Ring In and Ring Out ports (active) enabled on
this device."
::= { tokenRingD 3 }
deviceTRTotalTokenRingRingPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of Ring In and Ring Out ports on this
device."
::= { tokenRingD 4 }
deviceTRTotalTokenRingRings OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of (Token Ring) rings formed on this device."
::= { tokenRingD 5 }
-- board Object Definitions
--
-- This section will describe the management objects
-- associated with a board. The board variables have been broken down into
-- Network type independent and Network Type Dependent variables.
--
-- Formal Definitions within board
commonB OBJECT IDENTIFIER ::= { rr2board 1 }
ethernetB OBJECT IDENTIFIER ::= { rr2board 2 }
tokenRingB OBJECT IDENTIFIER ::= { rr2board 3 }
fddiB OBJECT IDENTIFIER ::= { rr2board 4 }
--
-- Instance Identifiers for board s
--
-- The Instance Identifiers for board objects is the
-- number of the slot in the MMAC cage. The current valid range
-- is from 1-8. The IRM being in slot 1. B indicates the
-- instance of a board number.
--
--
-- common board Objects
boardIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot number of this board."
::= { commonB 1 }
boardName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name of the board. This field will only contain
printable ASCII characters."
::= { commonB 2 }
boardType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the MIM. (eg. FOT, TPT, etc). See appendix A for
encoding."
::= { commonB 3 }
boardTotalPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of ports supported on this board."
::= { commonB 4 }
boardSTATUS OBJECT-TYPE
SYNTAX INTEGER
{
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"The administrative status of this MIM."
::= { commonB 5 }
boardPortsOn OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of operating ports on the board."
::= { commonB 6 }
-- Ethernet board Objects
boardTotalPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of packets this board has seen since
the last reset."
::= { ethernetB 1 }
boardErrorPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that have experienced an error.
VAlid only on the IRBM, IRM2, and MiniMMAC."
::= { ethernetB 2 }
boardTransColl OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of transmit collisions this board has
detected."
::= { ethernetB 3 }
boardRecColl OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of Receive mode collisions this board has
detected."
::= { ethernetB 4 }
boardAlign OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of mis-aligned frames this board has
detected. Only valid for the IRBM, IRM2, and MiniMMAC."
::= { ethernetB 5 }
boardCRC OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of packets with bad CRC detected. Only valid
on IRBM, IRM2, and MiniMMAC."
::= { ethernetB 6 }
boardRunt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of runt frames detected by this board. Valid
fr the IRBM, IRM2, and MiniMMAC only."
::= { ethernetB 7 }
boardOOWColl OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of out-of-window collisions detected by this
board. Only valid on the IRBM, IRM2, and MiniMMAC."
::= { ethernetB 8 }
boardNoResources OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of times The no resources condition was
detected for this board."
::= { ethernetB 9 }
boardRecBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of bytes detected on the network. Valid only
on the IRBM, IRM2, and MiniMMAC."
::= { ethernetB 10 }
boardGiants OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets longer than 1518 bytes detected on
this board."
::= { ethernetB 11 }
-- Token Ring board Objects
boardTotalRingPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of ring ports on this board. Currently, zero or
two."
::= { tokenRingB 1 }
boardTotalStationPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of station ports on this board."
::= { tokenRingB 2 }
boardModeStatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The board is configured for 2 == Auto Mode or 1 == Management Mode"
::= { tokenRingB 3 }
boardTotalRingPortsOn OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of enabled ring ports on this board."
::= { tokenRingB 4 }
boardTotalStationPortsOn OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of enabled station ports on this board."
::= { tokenRingB 5 }
boardSpeed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Speed 4 == 4 Mhz
Speed 16 == 16 Mhz"
::= { tokenRingB 6 }
boardRingSpeedFault OBJECT-TYPE
SYNTAX INTEGER {
noFaultDetected (1),
faultDetected (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Data speed of station mismatches configuration speed of board.
board is automatically bypassed."
::= { tokenRingB 7 }
-- Port Object Definitions
--
-- This section will define the objects associated with
-- ports. Here again the objects are deperateed into common objects and
-- network type specific objects.
--
-- Formal Definitions within Port
commonP OBJECT IDENTIFIER ::= { rr2port 1 }
ethernetP OBJECT IDENTIFIER ::= { rr2port 2 }
tokenRingP OBJECT IDENTIFIER ::= { rr2port 3 }
fddiP OBJECT IDENTIFIER ::= { rr2port 4 }
--
--
-- Instance Identifiers for port s
--
-- The instance identifiers for port objects are board#
-- and port#. The format of the port identifier is thus:Board_num.Port_num or B.P
portIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot number of this port."
::= { commonP 1 }
portMediaType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the port. (eg. FOT, TPT, etc). See appendix
A for values."
::= { commonP 2 }
portAdminState OBJECT-TYPE
SYNTAX INTEGER
{
off(1),
on( 2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The administrative status of this port."
::= { commonP 3 }
portSourceAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A source address that has been seen on this port."
::= { commonP 4 }
-- Ethernet port Objects
portTopologyType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The topological type of the port.
{
Station(1)
Link(2)
}"
::= { ethernetP 1 }
portLinkStatus OBJECT-TYPE
SYNTAX INTEGER
{
linkSignalInactive(1),
linkSignalActive(2),
linkSignalNotSupported(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the link signal for this port"
::= { ethernetP 2 }
portStatus OBJECT-TYPE
SYNTAX INTEGER
{
active(1),
segmented(2)
}
ACCESS read-only
STATUS mandatory
::= { ethernetP 3 }
portTotalPkts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of packets this port has seen since
the last reset."
::= { ethernetP 4 }
portErrorPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that have experienced an error.
Valid only on the IRBM, IRM2, and MiniMMAC"
::= { ethernetP 5 }
portXmitColls OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of Transmit mode collisions this port has
detected. Only valid on IRBM, IRM2, and MiniMMAC."
::= { ethernetP 6 }
portRecColls OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of Receive mode collisions this port has
detected. Only valid on IRBM, IRM2, and MiniMMAC."
::= { ethernetP 7 }
portAlign OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of mis-aligned frames this port has
detected. Only valid for the IRBM, IRM2, and MiniMMAC."
::= { ethernetP 8 }
portCRC OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of packets with bad CRC detected. Only valid
on IRBM, IRM2, and MiniMMAC."
::= { ethernetP 9 }
portRunt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of runt frames detected by this port. Valid
for the IRBM, IRM2, and MiniMMAC only."
::= { ethernetP 10 }
portOOWColl OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of out-of-window collisions detected by this
port. Only valid on the IRBM, IRM2, and MiniMMAC."
::= { ethernetP 11 }
portNoResorces OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of times the no resource condition is
detected on this port."
::= { ethernetP 12 }
portRecBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of bytes detected on the network. Valid only
on the IRBM, IRM2, and MiniMMAC."
::= { ethernetP 13 }
portGiants OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of frames longer than 1518 bytes detected on this
port."
::= { ethernetP 14 }
portRedundCrt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The redundant circuit with which this port is
associated."
::= { ethernetP 15 }
portRedundType OBJECT-TYPE
SYNTAX INTEGER
{
notUsed(1),
primary(3),
backup(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The type of port this port is in the redundant circuit."
::= { ethernetP 16 }
portRedundStatus OBJECT-TYPE
SYNTAX INTEGER
{
notUsed(1),
active(2),
inactive(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The current state of this port is in the redundant
circuit."
::= { ethernetP 17 }
portForceLinkType OBJECT-TYPE
SYNTAX INTEGER
{
notForced(1),
forced(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable forces a port to be a link port."
::= { ethernetP 18 }
-- Token Ring Port Objects
--
-- Token Ring Port Objects are further broken down into station objects
-- and Ring-In/Ring-Out objects. The formal defintions is:
stationP OBJECT IDENTIFIER ::= { tokenRingP 1 }
ringP OBJECT IDENTIFIER ::= { tokenRingP 2 }
stationPortLinkStatus OBJECT-TYPE
SYNTAX INTEGER {
linkSignalInactive(1),
linkSignalActive(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"When station is supplying phantom current the Link Signal is
active. When there is no phantom current the Link Signal is inactive."
::= { stationP 1 }
stationPortLinkStateTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The amount of time (in seconds) elapsed since the station port
last changed state."
::= { stationP 2 }
-- This section will define the objects associated with Ring In and Ring
-- Out ports, e.g. TRMIM-10R.
ringPortLinkStatus OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Off (wrapped).
On (active)."
::= { ringP 1 }
ringPortLinkStateTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The amount of time (in seconds) elapsed since ring port last
changed state."
::= { ringP 2 }
-- Product specific Objects
--
-- For each of the individual repeaters/bridges there are
-- several objects that particular to that product. below is a
-- description of these objects.
--
-- Formal description of Product specfics
productRev1 OBJECT IDENTIFIER ::= { product 1 }
iRBM OBJECT IDENTIFIER ::= { productRev1 1 }
-- iRBM specific Objects
-- These objects are particular to the iRBM.
iRBMRevision OBJECT-TYPE
SYNTAX INTEGER
{
rev0(0),
rev1(1),
rev2(2),
rev3(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The revision of the IRBM board"
::= { iRBM 1 }
iRBMPortAssociation OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls how front panel ports are associated with the
bridge or the repeater. The valid values are:
Value AUI Port Fiber Port
0 Bridge Redundant
1 Redundant Bridge
2 Bridge Repeater
3 Repeater Bridge
4 Redundant Repeater
5 Repeater Redundant
Note: only values 0 and 1 are valid for rev 2 boards and
before."
::= { iRBM 2 }
-- Subsystem defined objects
mMAC OBJECT IDENTIFIER ::= { subsystem 1 }
-- MMAC Objects
fnb OBJECT IDENTIFIER ::= { mMAC 1 }
fnbConnectedLeft OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Connected Left board (board n + 1) has the following states:
Detached == 1 (Management (only management) detached,
read/write).
Attached == 2 (Management/AutoMode attached,
read/write).
Faulted == 3 (Management/AutoMode tried to attach
but failed read ONLY)."
::= { fnb 1 }
fnbConnectedRight OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Connected Right board (board n - 1) has the following states:
Detached == 1 (Management (only management) detached,
read/write).
Attached == 2 (Management/AutoMode attached,
read/write ).
Faulted == 3 (Management/AutoMode tried to attach
but failed read ONLY)."
::= { fnb 2 }
fnbBoardBypassState OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Off == 1 (NOT bypassed).
On == 2 (bypassed)."
::= { fnb 3 }
-- TrapTypes
--
-- This section will describe the trap types that the
-- repeater section of the IRBM can generate. These are not
-- objects, but Object identifers used to indicate the specfic
-- trap. They are taken from the object space and are thus
-- documented here.
--
-- The SNMP protocol provides a mechanism for
-- asynchronusly notifying management stations of significant
-- changes in the network. This mechanism is the SNMP trap
-- message. This document will describe the general format for
-- all trap messages that Cabletron products will generate as
-- well as the specific traps that the will be generated by the
-- IRBM.
--
-- Trap Formats
--
-- The SNMP trap messages are composed of two user
-- definable areas: the specific trap type and the VarBindings
-- (eg. the interesting information). The specific trap type is
-- an INTEGER that is used to determine the specific trap that
-- has occurred. The "interesting information" contains a group
-- of objects identifiers (OID) and their values that provide
-- information about the trap.
--
--
-- Trap Description
--
-- PortSegmenting
--
-- Specfic Trap Type Code - 0x101
--
-- When a port goes from operational to segmented, a trap
-- will be generated. For these purposes, the port state will
-- be sampled every XXX seconds, thus it will be statistically
-- possible to miss oscillating circuits.
--
-- The interesting information will include:
-- - Board number
-- - Port number
--
-- Trap Description
--
-- PortUnsegementing
-- Specfic Trap Type Code - 0x102
--
-- When it is detected that a previously segmented port
-- has gone operational, a trap will be generated. This is
-- also sampled, thus a trap may not be generated for each
-- transition.
--
-- The interesting information will include:
-- - Board number
-- - Port number
--
--
--
-- Trap Description
--
-- PortLinkUp
--
-- Specfic Trap Type Code - 0x103
--
-- This trap will be generated when it is determined that
-- MAU has been attached to the MMAC. This is only appropriate
-- for MIMs that support the concept of a link state.
--
-- The interesting information will include:
-- - Board number
-- - Port number
--
-- Trap Description
--
-- PortLinkDown
--
-- Specfic Trap Type Code - 0x104
--
-- This trap will be generated when a previously attached
-- MAU is removed or powered down. Again, this is only
-- appropriate for MIM's that support link state.
--
-- The interesting information will include:
-- - Board number
-- - Port number
--
-- Trap Description
-- NewSourceAddress
-- Specfic Trap Type Code - 0x105
--
-- This trap will be generated when the MMAC detects the
-- existence of a new source address on one of it's ports.
--
-- The interesting information will include:
--
-- - Board number
-- - Port number
-- - The new source address
--
-- Trap Description
-- SourceAddressTimeout
--
-- Specfic Trap Type Code - 0x106
--
-- This trap will indicate that the MMAC has not detected
-- a packet generated by this source address within a certain
-- timeout.
--
--
--
-- The interesting information will include:
--
-- - Board number
-- - Port number
-- - Source address that timed out.
--
-- Trap Description
--
-- BoardRemoval
--
-- Specfic Trap Type Code - 0x107
--
-- This trap will be generated when the MMAC detects that
-- MIM has been removed.
--
-- The interesting information will include:
--
-- - Board number
--
-- Trap Description
-- BoardInsertion
--
-- Specfic Trap Type Code - 0x108
--
--
-- This trap will be generated when the MMAC determines
-- that a new board has been inserted.
--
-- The interesting information will include:
--
-- - Board number
-- - Board type
--
-- Trap Description
-- ActivePortInRedundantCircuitFailed
--
-- Specfic Trap Type Code - 0x109
--
-- This trap will be generated when the active port in a
-- redundant circuit has failed polling. This will indicate the
-- activation of redundancy.
--
-- The interesting information will include:
--
-- - Board number
-- - Port number
-- - Circuit number
--
-- Trap Description
-- RedundantPortActivated
--
-- Specfic Trap Type Code - 0x10a
--
--
--
-- This trap indicates that a new port has been activated
-- in a redundant circuit. This does NOT indicate that this
-- port is usable, but is being tested. If the port fails the
-- above (3.9) trap will be generated.
--
-- The interesting information will include:
--
-- - Board number
-- - Port number
-- - Circuit number
--
-- Trap Description
-- RedundantPortTestFailed
--
-- Specfic Trap Type Code - 0x10b
--
--
--
-- This trap will be generated when the MMAC executes it's
-- periodic redundancy diagnostics and finds on of the ports in
-- a redundant circuit has failed. This message will not
-- indicate that redundancy has been activated, just that the
-- port has failed and should be fixed before it is needed.
--
-- The interesting information will include:
--
-- - Board number
-- - Port number
-- - Circuit number
--
-- Trap Description
-- deviceTrafficThresholdExceeded
--
-- Specfic Trap Type Code - 0x10c
--
-- This trap will be generated when the traffic (good
-- packets per time interval) has been exceed for the entire
-- MMAC.
--
-- The interesting information will include:
--
-- - threshold value
-- - timebase value
--
-- Trap Description
-- deviceErrorThresholdExceeded
--
-- Specfic Trap Type Code - 0x10d
--
-- This trap will be generated when packets of the
-- selected error type exceeds a threshold percentage of the
-- good packets for a particular interval for the entire MMAC.
--
-- The interesting information will include:
--
-- - threshold value
--
--
-- - selected error type
-- - timebase
--
-- Trap Description
-- deviceCollsionThresholdExceeded
--
-- Specfic Trap Type Code - 0x10e
--
-- This trap will be generated when collsions exceed a
-- threshold percentage of the good packets for a particular
-- interval for the entire MMAC.
--
-- The interesting information will include:
--
-- - threshold value
-- - timebase
--
-- Trap Description
-- BoardTrafficThresholdExceeded
--
-- Specfic Trap Type Code - 0x10f
--
-- This trap will be generated when the traffic (good
-- packets per time interval) has been exceed for a particular
-- MIM.
--
-- The interesting information will include:
--
-- - threshold value
-- - timebase value
-- - board number
--
-- Trap Description
-- BoardErrorThresholdExceeded
--
-- Specfic Trap Type Code - 0x110
--
-- This trap will be generated when packets of the
-- selected error type exceeds a threshold percentage of the
-- good packets for a particular interval for a particular MIM.
-- This will most likely indicate a bad MIM.
--
-- The interesting information will include:
-- - threshold value
-- - selected error type
-- - timebase
-- - Board number
--
-- Trap Description
-- BoardCollisionThresholdExceeded
--
--
--
-- Specfic Trap Type Code - 0x111
--
--
-- This trap will be generated when collisions exceed a
-- threshold percentage of the good packets for a particular
-- interval for a particular MIM.
--
-- The interesting information will include:
--
-- - threshold value
-- - timebase
-- - Board number
--
-- Trap Description
-- PortTrafficThresholdExceeded
--
-- Specfic Trap Type Code - 0x112
--
--
-- This trap will be generated when the traffic (good
-- packets per time interval) has been exceed for a particular
-- port.
--
-- The interesting information will include:
--
-- - threshold value
-- - timebase value
-- - board number
-- - port number
--
-- Trap Description
-- PortErrorThresholdExceeded
--
-- Specfic Trap Type Code - 0x1113
--
--
--
-- This trap will be generated when packets of the
-- selected error type exceeds a threshold percentage of the
-- good packets for a particular interval for a particular
-- port.
--
-- The interesting information will include:
--
-- - threshold value
-- - selected error type
-- - timebase
-- - board number
-- - port number
--
--
-- Trap Description
-- PortCollisionThresholdExceeded
--
-- Specfic Trap Type Code - 0x114
--
-- This trap will be generated when collisions exceed a
-- threshold percentage of the good packets for a particular
-- interval for a particular port.
--
-- The interesting information will include:
--
-- - threshold value
-- - timebase
-- - board number
-- - port number
--
-- Trap Description
-- PortTypeChanged
--
-- Specfic Trap Type Code - 0x115
--
-- This trap indicates that a port has changed from a
-- station port to a link port or vice versa.
--
-- The interesting information is:
--
-- - Board number
-- - Port Number
-- - New type value
--
-- Trap Description
-- LockSTATUSChanged
--
-- Specfic Trap Type Code - 0x116
--
-- This trap is generated when the status of the address lock
-- changes.
--
-- The interesting information is:
--
-- - New lock status
--
--
-- Trap Description
-- PortSecurityViolation
--
-- Specfic Trap Type Code - 0x117
--
-- This trap is generated when a source address other than those
-- locked to a port is seen.
--
-- The interesting information is:
--
-- - Board number
-- - Port Number
-- - Violating Address
--
--
-- Trap Description
-- PortViolationReset
--
-- Specfic Trap Type Code - 0x118
--
-- This trap is generated when management intervention has
-- reset a port after a violation has occured.
--
-- The interesting information is:
--
-- - Board Number
-- - Port Number
--
-- Trap Description
-- EnvTempWarm
--
-- Specfic Trap Type Code - 0x119
--
-- This trap is generated when the device detects that the temperature
-- within the device has reached a WARM condition.
--
--
-- The interesting information is:
--
-- None
--
-- Trap Description
-- EnvTempHot
--
-- Specfic Trap Type Code - 0x11A
--
-- This trap is generated when the device detects a temperature
-- that is classified as HOT.
--
--
-- The interesting information is:
--
-- None
--
-- Trap Description
-- EnvVoltageLow
--
-- Specfic Trap Type Code - 0x11B
--
-- This trap is generated when a board detects that it's power supply
-- voltage is LOW.
--
--
-- The interesting information is:
--
-- - Board
--
-- Appendix A - Media type values
--
-- Board Type Value
--
-- MMAC Board & Port types
-- IRM 0x01
-- NB25,NB20 0x02
-- NB35 0x03
-- THIN_MIM 0x10,0x50
--
-- TRMIM_12 0x30
--
-- TRMIM_RPT 0x31
-- TRMIM_24 0x32
-- TRMIM_22 0x33
-- TRMIM_34 0x34
--
-- TRMIM_32 0x35
-- TRFOT_28 0x36
-- TRFOT_26 0x37
-- TRFOT_22 0x38
-- TRFOT_18 0x39
-- TRFOT_12 0x3A
-- TRFOT_16 0x3B
--
-- TPMIM_T1 0x41
-- TPMIM_T 0x42
-- TPMIM_T3 0x43
--
-- TPMIM_24 0x60
-- TPMIM_22 0x61
-- TPMIM_34 0x62
-- TPMIM_32 0x63
--
-- FO_22 0x70
-- FO_16 0x80
-- FOIRL 0x90
-- FOM_18 0x90
--
-- FOM_12 0x92
-- FOM_16 0x93
-- FOM_28 0x94
-- FOM_22 0x96
-- FOM_26 0x97
--
-- MT8MIM 0xA0
--
-- IRM2 0xB0
-- IRBM 0xB1
-- TRMBM 0xB4
-- IRM/SNMP 0xB5
--
-- FOT_12 0xC0
--
-- TPT 0xD0
--
-- FOT_6 0xE0
-- NOMIM 0xFF
--
--
-- Device Codes
-- MiniMMAC 0x10010
--
-- Multi-Port Interfaces Modules
-- MPIM-X 0x20000
-- MPIM-A 0x20001
-- MPIM-C 0x20002
-- MPIM-T 0x20003
-- MPIM-F2 0x20004
-- MPIM-F1 0x20005
-- MPIM-T1 0x20006
-- MPIM-B 0x20007 - BLANK
--
--
-- Single-Port Interface Modules
--
-- SPIM-A 0x20001
-- SPIM-C 0x20002
-- SPIM-T 0x20003
-- SPIM-F2 0x20004
-- SPIM-F1 0x20005
-- SPIM-T1 0x20006
-- SPIM-B 0x20007 - BLANK
--
-- MRXI Interface modules
--
-- MRXI 0x30043
-- MRXI-28 0x300A0
-- MRXI-2 0x30042
--
-- Cabletron Management Information Base
-- For the Ethernet Bridge (IRBM, NB25E, and NB20E)
-- By: Gayle Delaney
-- Revision 0.7
-- Date: February 21, 1991
--
--
-- REVISION HISTORY
--
-- Rev. 0.1 - Initial revision.
-- Compatible with versions 0.00.02 and 0.00.03 of the SNMP NB25E
-- bridge.
--
-- Rev. 0.2 - Revised and updated.
-- Added Bridgerev1 to object identifiers.
--
-- Rev. 0.3 - Revised and updated.
-- Added PortRuntPackets, PortOversizePackets, and PortFrFilt.
-- Changed syntax of all four AcqCreate objects and AcqDelete
-- object to INTEGER.
-- Changed syntax of all four PermCreate object and PermDelete
-- object to INTEGER.
--
-- Rev. 0.4 - Revised and updated.
-- Added trap object identifiers.
--
-- Rev. 0.5 - Changed certain device and port objects to counter types.
--
-- Rev. 0.6 - Added AcqSrcAddress and PermSrcAddress.
--
-- Rev. 0.7 - Updated DeviceRestoreSettings and Traps.
bridgeRev1 OBJECT IDENTIFIER ::= { bridge 1 }
bdgdevice OBJECT IDENTIFIER ::= { bridgeRev1 1 }
bdgPort OBJECT IDENTIFIER ::= { bridgeRev1 2 }
filterDB OBJECT IDENTIFIER ::= { bridgeRev1 3 }
trapTypes OBJECT IDENTIFIER ::= { bridgeRev1 4 }
bdgTables OBJECT IDENTIFIER ::= { bridgeRev1 5 }
acqDB OBJECT IDENTIFIER ::= { filterDB 1 }
permDB OBJECT IDENTIFIER ::= { filterDB 2 }
specialDB OBJECT IDENTIFIER ::= { filterDB 3 }
acqStats OBJECT IDENTIFIER ::= { acqDB 1 }
acqOptions OBJECT IDENTIFIER ::= { acqDB 2 }
permStats OBJECT IDENTIFIER ::= { permDB 1 }
permOptions OBJECT IDENTIFIER ::= { permDB 2 }
specStats OBJECT IDENTIFIER ::= { specialDB 1 }
specFilters OBJECT IDENTIFIER ::= { specialDB 2 }
-- Device Object Definitions
--
-- This section defines the objects under the Device node.
--
-- Instance Identifiers for Device Objects
--
-- There is only one instance of a Device object, thus the Instance
-- Identifier is 0.
--
-- Device Objects
bdgdeviceDisableBdg OBJECT-TYPE
SYNTAX INTEGER
{
disableBridge (0),
enableBridge (1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates if the bridge will be disabled."
::= { bdgdevice 1 }
bdgdeviceRestoreSettings OBJECT-TYPE
SYNTAX INTEGER
{
restoreSettings (0)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Restore the following settings to their default values:
Bridge Name to ETHERNET_BRIDGE,
Location to LOCAL,
Port 1 Name to PORT_1,
Port 2 Name to PORT_2,
Port 1 Network Name to LAN_1,
Port 2 Network Name to LAN_2,
Ageing Time for Acquired Database to 300 seconds,
Erase the acquired database,
Erase the permanent database,
Place sixteen default multicast addresses into
the permanent and acquired databases,
Type of Spanning Tree to 802.1,
Type of Filtering to IEEE 802.1,
Bridge Max Age to 20 seconds,
Bridge Forward Delay to 15 seconds,
Bridge Hello Time to 2 seconds,
Bridge Priority to 8000,
Port 1 Priority to 80,
Port 2 Priority to 80,
Port 1 Path Cost to 100,
Port 2 Path Cost to 100,
Restart the bridge."
::= { bdgdevice 2 }
bdgdeviceBdgName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined name (up to 32 characters long) of the bridge.
The default bridge name is ETHERNET_BRIDGE."
::= { bdgdevice 4 }
bdgdeviceNumPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of ports present on the bridge."
::= { bdgdevice 5 }
bdgdeviceType OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of bridge, NB25E, IRBM, or NB20E."
::= { bdgdevice 6 }
bdgdeviceVersion OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The release version of the firmware installed in the bridge."
::= { bdgdevice 7 }
bdgdeviceLocation OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined name to indicate the location of the bridge on
the network. The default location name is LOCAL."
::= { bdgdevice 8 }
bdgdeviceStatus OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the bridge, ON-LINE, STAND BY or DISABLED."
::= { bdgdevice 9 }
bdgdeviceRestartBdg OBJECT-TYPE
SYNTAX INTEGER
{
restartBridge (0)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Force the bridge to undergo a software reset."
::= { bdgdevice 10 }
bdgdeviceFrFwd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames forwarded by the bridge."
::= { bdgdevice 11 }
bdgdeviceFrRx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames received by the bridge."
::= { bdgdevice 12 }
bdgdeviceFrFlt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames filtered by the bridge."
::= { bdgdevice 13 }
bdgdeviceErr OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of network errors that have occurred."
::= { bdgdevice 14 }
bdgdeviceSwitchSetting OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current switch settings read from the bridge
hardware."
::= { bdgdevice 15 }
bdgdeviceNumRestarts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the bridge has been powered up or restarted."
::= { bdgdevice 16 }
bdgdeviceTypeFiltering OBJECT-TYPE
SYNTAX INTEGER
{
ieee8021 (0),
specialDB (1),
both (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The type of filtering to be performed by the bridge. The default
is IEEE 802.1."
::= { bdgdevice 17 }
bdgdeviceSTAProtocol OBJECT-TYPE
SYNTAX INTEGER
{
ieee8021 (0),
dec (1),
none (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The spanning tree algorithm under which the bridge is operating.
The selections are as follows:
- IEEE 802.1 compliant spanning tree algorithm
environment (802.1)
- DEC LAN Bridge 100 environment (DEC)
- Without the spanning tree algorithm enabled (NONE)
The default is 802.1."
::= { bdgdevice 18 }
bdgdeviceBridgeID OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The unique identifier of the bridge. The first two bytes of the
identifier are the bridge priority and the last six bytes are the
Ethernet address."
::= { bdgdevice 19 }
bdgdeviceTopChgCnt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the bridge's Topology Change Flag has been
changed since the bridge was powered up or initialized."
::= { bdgdevice 20 }
bdgdeviceRootCost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The cost of the path to the root from this bridge."
::= { bdgdevice 21 }
bdgdeviceRootPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port identifier for the port which offers the lowest cost
path to the root, i.e. that port for which the sum of the values
of the designated cost and path cost parameters held for the port
is lowest."
::= { bdgdevice 22 }
bdgdeviceHelloTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time interval between the transmission of Configuration
BPDU's by a bridge which is attempting to become the root or is
the root."
::= { bdgdevice 23 }
bdgdeviceBdgMaxAge OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value of the Max Age parameter when the bridge is the root
or is attempting to become the root. A time of 6 to 40 seconds is
allowed. The default is 20 seconds."
::= { bdgdevice 24 }
bdgdeviceBdgFwdDly OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value of the forward delay parameter when the bridge is the
root or is attempting to become the root. A time of 4 to 30
seconds is allowed."
::= { bdgdevice 25 }
bdgdeviceTimeTopChg OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time in seconds that has elapsed since the bridge's Topology
Change Flag last recorded the value of a topology change."
::= { bdgdevice 26 }
bdgdeviceTopChg OBJECT-TYPE
SYNTAX INTEGER
{
noTopologyChangeInProgress (0),
topologyChangeInProgress (1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates if a bridge topology change is in progress."
::= { bdgdevice 27 }
bdgdeviceDesigRoot OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The unique identifier of the bridge recorded as the root."
::= { bdgdevice 28 }
bdgdeviceMaxAge OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum age of received protocol information before it is
discarded."
::= { bdgdevice 29 }
bdgdeviceHoldTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The minimum time period elapsing between the transmission of
configuration BPDU's through a given bridge port."
::= { bdgdevice 30 }
bdgdeviceFwdDly OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time spent in the listening state while moving from the
blocking state to the learning state, or the time spent in the
learning state while moving from the listening state to the
forwarding state."
::= { bdgdevice 31 }
bdgdeviceBdgHello OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value of the Hello Time parameter when the bridge is the
root or is attempting to become the root. A time of 1 to 10
seconds is allowed. The default is 2 seconds."
::= { bdgdevice 32 }
bdgdeviceBdgPriority OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The part of the bridge address that contains the identifier used
in the spanning tree for priority comparisons. Allowed range is 0
through FFFF. The default is 8000."
::= { bdgdevice 33 }
bdgdeviceResetCounts OBJECT-TYPE
SYNTAX INTEGER
{
resetCounts (0)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset all counters to zero."
::= { bdgdevice 34 }
bdgdeviceUptime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time, in seconds, that has elapsed since the bridge was last
reset or initialized."
::= { bdgdevice 35 }
bdgdeviceTrapType OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the object identifier of the first VarBinding in the
last trap generated by the bridge."
::= { bdgdevice 36 }
-- Port Object Definitions
--
-- This section defines the objects under the Port node.
--
-- Instance Identifiers for Port Objects
--
-- The Instance Identifier for port objects is the number of the port on
-- the bridge. Valid instance identifiers for the ports on the IRBM,
-- NB25E, and NB20E bridges are 1 and 2.
--
-- Port Objects
bdgPortAddress OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Ethernet address of the port."
::= { bdgPort 1 }
bdgPortName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined name assigned to the port. The default port 1
name is PORT_1 and the default Port 2 name is PORT_2."
::= { bdgPort 2 }
bdgPortType OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IEEE specification the port meets, e.g. 802.3."
::= { bdgPort 3 }
bdgPortStatus OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status in which the port is operating. The status messages
for Ports 1 and 2 are:
OFF - The port is off, due to a failed network interface
chip associated with that port.
OK/SQE ON - The port is communicating with the network
and the transceiver making the connection to the network
has SQE enabled.
OK/SQE OFF - The port is communicating with the network
and the transceiver making the connection to the network
has SQE disabled.
CARRIER LOST - Communication with the network has not
been established or has been lost."
::= { bdgPort 4 }
bdgPortNetName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined name assigned to a network segment connected to
the port. The default network name for Port 1 is LAN_1 and the
default network name for Port 2 is LAN_2."
::= { bdgPort 5 }
bdgPortFrRx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames received at the specified port."
::= { bdgPort 6 }
bdgPortDisInb OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of valid frames that were received at the port
but then discarded by the bridge in the forwarding process."
::= { bdgPort 7 }
bdgPortFwdOutb OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames forwarded successfully to the appropriate
port."
::= { bdgPort 8 }
bdgPortDisLOB OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that were discarded by the bridge because
of a lack of buffer space to maintain the data."
::= { bdgPort 9 }
bdgPortDisTDE OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames that were intended for forwarding but were
discarded when the maximum time period set for transmission was
exceeded before forwarding was possible."
::= { bdgPort 10 }
bdgPortDisErr OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames that could not be transmitted because the
frame was too large for the attached network (1526 bytes,
including preamble, for 802.3 networks)."
::= { bdgPort 11 }
bdgPortColl OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of collisions that have occurred on the network at
the specified port."
::= { bdgPort 12 }
bdgPortTxAbrt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of transmissions that have been aborted due to
excessive collisions (over 16 attempts to transmit the same
packet)."
::= { bdgPort 13 }
bdgPortOowColl OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of collisions out of the standard collision window
(51.2 uS). This indicates a network problem."
::= { bdgPort 14 }
bdgPortCRCErr OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets detected with Cyclical Redundancy Check
failures."
::= { bdgPort 15 }
bdgPortFrAlErr OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of errors due to misaligned packets."
::= { bdgPort 16 }
bdgPortPriority OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The part of the port identifier which is used with the spanning
tree algorithm when determining which port in a LAN segment has
priority. The default is 80."
::= { bdgPort 17 }
bdgPortState OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current state of the port, DISABLED, LISTENING, LEARNING,
FORWARDING or BLOCKING."
::= { bdgPort 18 }
bdgPortPathCost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The contributory cost of the applicable port to the overall cost
of the path when the specified port is the root port. Allowable
range is 1 to 65535. The default is 100."
::= { bdgPort 19 }
bdgPortDesigCost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The cost of the path of this port to the root bridge on the
network."
::= { bdgPort 20 }
bdgPortDesigBrdg OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The network address of the bridge that is assumed to be the root
bridge on the network."
::= { bdgPort 21 }
bdgPortDesigPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port identifier of the bridge port believed to be the
designated port for the LAN associated with the port."
::= { bdgPort 22 }
bdgPortTopChgAck OBJECT-TYPE
SYNTAX INTEGER
{
noTopologyChangeIsOccurring (0),
topologyChangeIsOccurring (1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of the topology change acknowledgement flag in the
next configuration BPDU to be transmitted on the associated port."
::= { bdgPort 23 }
bdgPortDesigRoot OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The unique bridge identifier of the bridge that is assumed to be
the root bridge on the network."
::= { bdgPort 24 }
bdgPortRuntPackets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets received at the indicated bdgPort that were
less than the IEEE 802.3 minimum Ethernet frame size of 64 bytes."
::= { bdgPort 25 }
bdgPortOversizePackets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets received at the indicated port that were
greater than the IEEE 802.3 maximum Ethernet frame size of 1518
bytes."
::= { bdgPort 26 }
bdgPortFrFilt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames received at the indicated port that were
filtered by the bridge."
::= { bdgPort 27 }
-- Acquired Database Statistical Object Definitions
--
-- This section defines the objects under the Acquired Database
-- Statistics node.
--
-- Instance Identifiers for Acquired Database Statistical Objects
--
-- There is only one instance of an Acquired Database Statistical object,
-- thus the Instance Identifier is 0.
--
-- Acquired Database Statistical Objects
acqTotalEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of entries in the acquired database."
::= { acqStats 1 }
acqMaxEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of entries allowed in the acquired database."
::= { acqStats 2 }
acqStaticEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of addresses added to the Acquired database by the
user or network manager."
::= { acqStats 3 }
acqStaticAgeTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The length of time allowed for a static entry in the Acquired
database to be inactive before it is dropped from the database.
This time is fixed at zero."
::= { acqStats 4 }
acqDynEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of entries that have been accumulated in the Acquired
database through the bridge's learning process."
::= { acqStats 5 }
acqDynAgeTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The length of time allowed for a dynamic entry in the acquired
database to be inactive before it is dropped from the database. A
time from 10 - 1,000,000 seconds is allowed. The default is 300
seconds."
::= { acqStats 6 }
acqEraseDatabase OBJECT-TYPE
SYNTAX INTEGER
{
eraseAcquiredDatabase (0)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set to zero to erase all entries in the acquired database."
::= { acqStats 7 }
-- Acquired Database Option Object Definitions
--
-- This section defines the objects under the Acquired Database
-- Option node.
--
-- Instance Identifiers for Acquired Database Option Objects
--
-- The instance identifier for the acquired database option objects is
-- the 6-byte Ethernet address of the device to be added, deleted or
-- displayed to/from the acquired database.
--
-- Acquired Database Option Objects
acqCreate00 OBJECT-TYPE
SYNTAX INTEGER
{
createAcquiredEntryFilterPort1FilterPort2 (0)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add an entry to the acquired database to filter packets entering
ports 1 and 2 if those packets are destined for the specified
address."
::= { acqOptions 1 }
acqCreate20 OBJECT-TYPE
SYNTAX INTEGER
{
createAcquiredEntryForwardPort1FilterPort2 (0)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add an entry to the acquired database to forward packets
entering port1 to port2 and filter packets entering port2 if
those packets are destined for the specified address."
::= { acqOptions 2 }
acqCreate01 OBJECT-TYPE
SYNTAX INTEGER
{
createAcquiredEntryFilterPort1ForwardPort2 (0)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add an entry to the acquired database to filter packets entering
port 1 and forward packets entering port 2 to port 1 if those
packets are destined for the specified address."
::= { acqOptions 3 }
acqCreate21 OBJECT-TYPE
SYNTAX INTEGER
{
createAcquiredEntryForwardPort1ForwardPort2 (0)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add an entry to the acquired database to forward packets
entering port 1 to port 2 and to forward packets entering port 2
to port 1 if those packets are destined for the specified
address."
::= { acqOptions 4 }
acqDelete OBJECT-TYPE
SYNTAX INTEGER
{
deleteAcquiredEntry (0)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Delete an entry from the acquired database."
::= { acqOptions 5 }
acqDispType OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display the entry type, STATIC or DYNAMIC."
::= { acqOptions 6 }
acqDispOutp1 OBJECT-TYPE
SYNTAX INTEGER
{
filter (0),
relay (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The outbound port for packets entering port 1."
::= { acqOptions 7 }
acqDispOutp2 OBJECT-TYPE
SYNTAX INTEGER
{
filter (0),
relay (1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The outbound port for packets entering port 2."
::= { acqOptions 8 }
acqSrcAddress OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The source address of this acquired database entry, i.e. the
instance."
::= { acqOptions 9 }
-- Permanent Database Statistical Object Definitions
--
-- This section defines the objects under the Permanent Database
-- Statistics node.
--
-- Instance Identifiers for Permanent Database Statistical Objects
--
-- There is only one instance of an Permanent Database Statistical
-- object, thus the Instance Identifier is 0.
--
-- Permanent Database Statistical Objects
permMaxEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of entries allowed in the permanent database."
::= { permStats 1 }
permCurrEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of entries currently recorded in the bridge's
permanent database."
::= { permStats 2 }
permEraseDatabase OBJECT-TYPE
SYNTAX INTEGER
{
erasePermanentDatabase (0)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Erase all entries in the permanent database."
::= { permStats 3 }
-- Permanent Database Option Object Definitions
--
-- This section defines the objects under the Permanent Database
-- Option node.
--
-- Instance Identifiers for Permanent Database Option Objects
--
-- The instance identifier for the permanent database option objects is
-- the 6-byte Ethernet address of the device to be added, deleted or
-- displayed to/from the permanent database.
--
-- Permanent Database Option Objects
permCreate00 OBJECT-TYPE
SYNTAX INTEGER
{
createPermanentEntryFilterPort1FilterPort2 (0)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add an entry to the permanent database to filter packets
entering ports 1 and 2 if those packets are destined for the
specified address."
::= { permOptions 1 }
permCreate20 OBJECT-TYPE
SYNTAX INTEGER
{
createPermanentEntryForwardPort1FilterPort2 (0)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add an entry to the permanent database to forward packets
entering port 1 and filter packets entering port 2 if those
packets are destined for the specified address."
::= { permOptions 2 }
permCreate01 OBJECT-TYPE
SYNTAX INTEGER
{
createPermanentEntryFilterPort1ForwardPort2 (0)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add an entry to the permanent database to filter packets
entering port 1 and forward packets entering port 2 if those
packets are destined for the specified address."
::= { permOptions 3 }
permCreate21 OBJECT-TYPE
SYNTAX INTEGER
{
createPermanentEntryForwardPort1ForwardPort2 (0)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add an entry to the permanent database to forward packets
entering ports 1 and 2 if those packets are destined for the
specified address."
::= { permOptions 4 }
permDelete OBJECT-TYPE
SYNTAX INTEGER
{
deletePermanentEntry (0)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Delete an entry from the permanent database."
::= { permOptions 5 }
permDispType OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display the entry type, STATIC or DYNAMIC."
::= { permOptions 6 }
permDispOutp1 OBJECT-TYPE
SYNTAX INTEGER
{
filter (0),
relay (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The outbound port for packets entering port 1."
::= { permOptions 7 }
permDispOutp2 OBJECT-TYPE
SYNTAX INTEGER
{
filter (0),
relay (1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The outbound port for packets entering port 2."
::= { permOptions 8 }
permSrcAddress OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The source address in this permanent database entry, i.e. the
instance."
::= { permOptions 9 }
-- Special Database Statistical Object Definitions
--
-- This section defines the objects under the Special Database
-- Statistical node.
--
-- Instance Identifiers for Special Database Statistical Objects
--
-- There is only one instance of a Special Database Statistical object,
-- thus the Instance Identifier is 0.
--
-- Special Database Statistical Objects
specNumEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of filters in the special database."
::= { specStats 1 }
specMaxEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of filters the special database can contain."
::= { specStats 2 }
specNextFilterNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of the next available filter that can be added to the
special database."
::= { specStats 3 }
-- Special Database Filter Object Definitions
--
-- This section defines the objects under the Special Database
-- Filter node.
--
-- Instance Identifiers for Special Database Filter Objects
--
-- The instance identifier of the special database filter objects
-- is the filter number, values from 1 through 10 are allowed.
--
-- Special Database Filter Objects
specEnable OBJECT-TYPE
SYNTAX INTEGER
{
disableFilter (0),
enableFilter (1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or disable the filter."
::= { specFilters 1 }
specPort1 OBJECT-TYPE
SYNTAX INTEGER
{
filter (0),
relay (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set port 1 to filter or forward packets."
::= { specFilters 2 }
specPort2 OBJECT-TYPE
SYNTAX INTEGER
{
filter (0),
relay (1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set port 2 to filter or forward packets."
::= { specFilters 3 }
specDestAddress OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set the special database to filter packets with a specific
destination address."
::= { specFilters 4 }
specSrcAddress OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set the special database to filter packets with a specific
source address."
::= { specFilters 5 }
specType OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set the special database to filter packets with a specific type
field."
::= { specFilters 6 }
specDataField OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set the special database to filter packets based on the first
sixteen bytes of data in the packet."
::= { specFilters 7 }
specDeleteFilter OBJECT-TYPE
SYNTAX INTEGER
{
deleteFilter (0)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Delete a filter from the special database."
::= { specFilters 8 }
-- TRAP TYPES OBJECT DEFINITIONS
--
-- This section describes the trap types that the bridge can generate. These
-- are not objects, but Object Identifiers used to indicate the specific trap.
-- They are taken from the object space and are thus documented here.
--
-- The SNMP trap messages are composed of two user definable areas:
-- a) the specific trap type and
-- b) the VarBindings (e.g. the interesting information)
--
-- The specific trap type is an integer that is used to determine the
-- specific trap which has occurred. The "interesting information" contains
-- a group of object identifiers and their values that provide information
-- about the trap.
--
-- Trap Decription
--
-- BridgeStatus
--
-- Specific Trap Type Code - 0x0301
--
-- When the bridge status changes, a trap will be generated. The
-- interesting information includes the current status of the bridge.
--
--
-- Trap Description
--
-- AcqDbaseFull
--
-- Specific Trap Type Code - 0x0302
--
-- When the acquired portion of the bridge's filtering database is full, a
-- trap is generated. The interesting information included with this trap
-- is the number of entries in the acquired database.
-- Formal definition of the Layer Management MIB. (e.g. PC cards )
lmcommon OBJECT IDENTIFIER ::= { layerMgmt 1 }
mAC OBJECT IDENTIFIER ::= { layerMgmt 2 }
ieee8023 OBJECT IDENTIFIER ::= { mAC 1 }
pcIF OBJECT IDENTIFIER ::= { ieee8023 1 }
pcIfRev OBJECT IDENTIFIER ::= { pcIF 1 }
pcDeviceName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Name of the PC device"
::= { pcIfRev 1 }
pcBoardType OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An object Identifier that indicates the type of the PC
board. This will include MAC type and Media type."
::= { pcIfRev 2 }
pcOwnerName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The owner of this PC."
::= { pcIfRev 3 }
pcLocation OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A text description of the location of this PC."
::= { pcIfRev 4 }
pcMMACAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC address of the MMAC that this PC is connected to."
::= { pcIfRev 5 }
pcMMACBoard OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot number of the board in the MMAC that this PC is
connected to."
::= { pcIfRev 6 }
pcMMACPort OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of the port on the board of the MMAC that this
PC is connected to."
::= { pcIfRev 7 }
pcApplication OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A text description of the network application running on
this PC."
::= { pcIfRev 8 }
pcDriverRev OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The revision of the LAN card driver."
::= { pcIfRev 9 }
pcOnboardMemory OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Kilobytes of memory (eg. a 16K board would
reply 16)"
::= { pcIfRev 10 }
pcComment OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A user-defined character string."
::= { pcIfRev 11 }
pcMACAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC address of the PC card."
::= { pcIfRev 12 }
pcFramesXmit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of MAC frames transmitted by this PC card."
::= { pcIfRev 13 }
pcBytesXmit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number bytes transmitted by this PC card."
::= { pcIfRev 14 }
pcMcastXmit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of multicasted frames sent by this PC card."
::= { pcIfRev 15 }
pcBcastXmit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of broadcast frames from this PC card."
::= { pcIfRev 16 }
pcDeferXmit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of transmit packets that were deferred due to
busy media."
::= { pcIfRev 17 }
pcSglColl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of transmit packet experiencing a single
collision."
::= { pcIfRev 18 }
pcMultiColl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of transmit packets that have experienced
multiple collisions."
::= { pcIfRev 19 }
pcTotXmitErrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of transmit errors."
::= { pcIfRev 20 }
pcLateColls OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of transmit packets that experienced late
collisions."
::= { pcIfRev 21 }
pcXcessColls OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of transmit packets aborted due to excess
collisions."
::= { pcIfRev 22 }
pcCarrErr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of transmit packets that experience carrier
sense errors (ie. lose carrier during transmission)."
::= { pcIfRev 23 }
pcFramesRec OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames received."
::= { pcIfRev 24 }
pcBytesRec OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bytes received by this station."
::= { pcIfRev 25 }
pcMcastRec OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of multicasted frames received."
::= { pcIfRev 26 }
pcBcastRec OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of broadcast packets received."
::= { pcIfRev 27 }
pcTotRecErrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of receive errors."
::= { pcIfRev 28 }
pcTooLong OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets received that are too long (over 1518
bytes)."
::= { pcIfRev 29 }
pcTooShort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that are too short. (under 64 bytes
long)."
::= { pcIfRev 30 }
pcAlignErrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of alignment errors in receive packets."
::= { pcIfRev 31 }
pcCRCErrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of receive packets with CRC errors."
::= { pcIfRev 32 }
pcLenErrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets whose length is not equal to the
number of bytes received."
::= { pcIfRev 33 }
pcIntRecErr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of receive packets that experienced internal
errors (eg. no receive buffers)."
::= { pcIfRev 34 }
pcSqeErr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of SQE errors."
::= { pcIfRev 35 }