-- Copyright (C) BTI Systems Inc. 2003-2010. All Rights Reserved.
--
-- The information contained herein is the property of BTI Systems Inc.
-- and is strictly confidential. Except as expressly authorized in
-- writing by BTI Systems Inc., the holder shall keep all information
-- contained herein confidential, shall disclose the information only
-- to its employees with a need to know, and shall protect the
-- information, in whole or in part, from disclosure and dissemination
-- to third parties with the same degree of care it uses to protect
-- its own confidential information, but with no less than reasonable
-- care. Except as expressly authorized in writing by BTI Systems Inc.,
-- the holder is granted no rights to use the information contained
-- herein.
------------------------------------------------------------------------
------------------------------------------------------------------------
BTI-OL-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, IpAddress,
Unsigned32
FROM SNMPv2-SMI
RowStatus, DisplayString, TEXTUAL-CONVENTION, DateAndTime
FROM SNMPv2-TC
btiModules
FROM BTI-MIB
opticalLayer, olEvtNotifications, olCondNotifications, trapSeqNum,
evtDateAndTime, evtDescription, evtObjectType, evtCodeType,
condReportType, condDateAndTime, condSeverity, condServiceAffecting,
condDescription, condObjectType, condCodeType, tcaIntervalType,
tcaDateAndTime, tcaMontype, tcaValue, tcaThreshold
FROM BTI-7000-MIB
CpType, BERType, AdminStatus, OperStatus, OperStatQlfr,
HoursAndMinutes, FiberType, FixedX10, FixedX100, PMIntervalType,
PMValidity, InitializeCmd
FROM BTI-TC-MIB;
olMib MODULE-IDENTITY
LAST-UPDATED "201208171200Z" -- Friday, August 17, 12:00:00 EST 2012
ORGANIZATION "BTI Systems Inc."
CONTACT-INFO "Technical Support
BTI Systems Inc.
50 Northside Road
Ottawa, Ontario, Canada K2H 5Z6
(613) 248-9154
support@btisystems.com"
DESCRIPTION "The external MIB definitions for the managenent of
the BTI Dynamic Optical Layer components including DLA-series
amplifiers and ROB-series ROADM modules."
REVISION "201208171200Z" -- Friday, August 17, 12:00:00 EST 2012
DESCRIPTION "MIB Updates for BTI 7000 Rel 10.1.0:
- deleted un-implemented table olDegreeTable
- added new traps for Connection Mismatch feature:
olPortCondNotification.0.17 - olPortCondNotification.0.20
- added new WCH traps for refined add-channel power monitoring:
wchCondNotifications.0.13 - wchCondNotifications.0.18"
REVISION "201202101200Z" -- Friday, February 10, 12:00:00 EST 2012
DESCRIPTION "MIB Updates for BTI 7000 Rel 9.2.0:
- added new object olPortRemoteId"
REVISION "201109261200Z" -- Monday, September 26, 12:00:00 EST 2011
DESCRIPTION "Initial version of the Optical Layer MIB."
::= { btiModules 6 }
------------------------------------------------------------------------
-- Optical Layer Textual Conventions
------------------------------------------------------------------------
OlGroupType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Identifies the configuration type of an optical layer
grouping."
SYNTAX INTEGER { none (1), -- Applies to an un-configured group
noEqlzTerm (2), -- Non-equalizing terminal
eqlzTerm (3), -- Channel equalizing terminal
noEqlzLine (4), -- Line amplifier node
eqlzLine (5), -- Channel equalizing line node
roadm (6) } -- Reconfigurable add drop node
OlPortType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Identifies the type of managed optical interface port
on an optical layer module."
SYNTAX INTEGER { line (1),
client (2),
dcm (3),
channel (4),
expansion (5) }
------------------------------------------------------------------------
-- The Optical Layer Group table is used to provision, de-provision,
-- edit and review optical layer module groupings.
------------------------------------------------------------------------
olGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF OlGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table lists all provisioned optical layer
module groupings on the node."
::= { opticalLayer 1 }
olGroupEntry OBJECT-TYPE
SYNTAX OlGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the optical layer
group table."
INDEX { olGroupIdx }
::= { olGroupTable 1 }
OlGroupEntry ::= SEQUENCE { olGroupIdx INTEGER,
olGroupType INTEGER,
olGroupId DisplayString,
olGroupCustom1 DisplayString,
olGroupCustom2 DisplayString,
olGroupCustom3 DisplayString,
olGroupRowStatus RowStatus }
olGroupIdx OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A number which uniquely identifies the optical layer
group within the node."
::= { olGroupEntry 1 }
olGroupType OBJECT-TYPE
SYNTAX OlGroupType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The optical layer group configuration type. This is a
mandatory object that must be specified when a row of
the table is created. The value of none is not
applicable for this object."
::= { olGroupEntry 2 }
olGroupId OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Textual data recorded by the user to briefly identify
the provisioned optical layer group in a manner useful
to the user."
DEFVAL { "" }
::= { olGroupEntry 3 }
olGroupCustom1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { olGroupEntry 4 }
olGroupCustom2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { olGroupEntry 5 }
olGroupCustom3 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { olGroupEntry 6 }
olGroupRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
optical layer group table."
::= { olGroupEntry 100 }
------------------------------------------------------------------------
-- The Optical Layer Equipment table is used to manage assignments of
-- provisioned equipment modules to optical layer groupings. Create an
-- entry in the table to assign a provisioned equipment module to an
-- optical layer group. Delete the entry to unassign the equipment.
------------------------------------------------------------------------
olEqptTable OBJECT-TYPE
SYNTAX SEQUENCE OF OlEqptEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table lists all provisioned equipment modules
that are assigned to an optical layer grouping."
::= { opticalLayer 3 }
olEqptEntry OBJECT-TYPE
SYNTAX OlEqptEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the optical layer
equipment table."
INDEX { olEqptCpTypeIdx, -- CP Type
olEqptShelfIdx, -- Shelf Num
olEqptSlotIdx } -- Slot Num
::= { olEqptTable 1 }
OlEqptEntry ::= SEQUENCE { olEqptCpTypeIdx CpType,
olEqptShelfIdx INTEGER,
olEqptSlotIdx INTEGER,
olEqptGroupNum INTEGER,
olEqptDegreeNum INTEGER,
olEqptRowStatus RowStatus }
olEqptCpTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of circuit pack of the equipment module that
is assigned to the optical layer group."
::= { olEqptEntry 1 }
olEqptShelfIdx OBJECT-TYPE
SYNTAX INTEGER (0|1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the equipment module that
is assigned to the optical layer group. For equipment
modules that do not reside in a shelf (40-channel
Mux/Demux), the value of this object is 0."
::= { olEqptEntry 2 }
olEqptSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot of the equipment module that is
assigned to the optical layer group. For equipment
modules that do not reside in an active shelf slot
(ex. 40-channel Mux/Demux), this object represents
the module index among modules attributed to shelf 0."
::= { olEqptEntry 3 }
olEqptGroupNum OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The optical layer group to which the equipment modules
is assigned."
::= { olEqptEntry 4 }
olEqptDegreeNum OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The optical layer group degree to which the equipment
module is assigned."
::= { olEqptEntry 5 }
olEqptRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries
in the optical layer equipment table, which in turn,
controls the assigning and unassigning of equipment
modules to/from an optical layer grouping."
::= { olEqptEntry 100 }
------------------------------------------------------------------------
-- The Optical Layer Port table is used to manage optical ports on
-- equipment modules assigned to optical layer groupings. Most entries
-- in the optical layer port table are auto-created when the supporting
-- equipment module is assigned to an optical layer group. Manual
-- provisioning and de-provisioning of client port C2 is supported on
-- ROB packs assigned to a Channel-equalizing Terminal or Reconfigurable
-- Add/Drop node group configuration.
------------------------------------------------------------------------
olPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF OlPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table lists all managed ports on equipment modules
assigned to optical layer groupings."
::= { opticalLayer 4 }
olPortEntry OBJECT-TYPE
SYNTAX OlPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the optical layer port
table."
INDEX { olPortCpTypeIdx, -- CP Type
olPortShelfIdx, -- Shelf Num
olPortSlotIdx, -- Slot Num
olPortTypeIdx, -- Port Type
olPortIdx } -- Port Num
::= { olPortTable 1 }
OlPortEntry ::= SEQUENCE { olPortCpTypeIdx CpType,
olPortShelfIdx INTEGER,
olPortSlotIdx INTEGER,
olPortTypeIdx OlPortType,
olPortIdx INTEGER,
olPortId DisplayString,
olPortCustom1 DisplayString,
olPortCustom2 DisplayString,
olPortCustom3 DisplayString,
olPortDWDMType INTEGER,
olPortGrid INTEGER,
olPortWavelength FixedX100,
olPortFrequency FixedX100,
olPortOperStatus OperStatus,
olPortOperStatQlfr OperStatQlfr,
olPortRemoteId DisplayString,
olPortExpCnxDegree INTEGER,
olPortActCnxDegree INTEGER,
olPortRowStatus RowStatus }
olPortCpTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of circuit pack on which the optical layer
port is located."
::= { olPortEntry 1 }
olPortShelfIdx OBJECT-TYPE
SYNTAX INTEGER (0|1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the optical layer
port is located."
::= { olPortEntry 2 }
olPortSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot on which the optical layer
port is located."
::= { olPortEntry 3 }
olPortTypeIdx OBJECT-TYPE
SYNTAX OlPortType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of optical layer port according to the
function it provides."
::= { olPortEntry 4 }
olPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..600)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the optical layer port of the specified
port type."
::= { olPortEntry 5 }
olPortId OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Textual data recorded by the user to briefly identify
the provisioned optical layer port in a manner useful
to the user."
DEFVAL { "" }
::= { olPortEntry 6 }
olPortCustom1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { olPortEntry 7 }
olPortCustom2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { olPortEntry 8 }
olPortCustom3 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { olPortEntry 9 }
olPortDWDMType OBJECT-TYPE
SYNTAX INTEGER { native (1),
alien (2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to configure the port for the type of DWDM composite
to which it is inter-connection. By default, all ports are
inter-connected with native optical layer DWDM composites.
For some configurations, client port 2 of ROB2 pack and
ROB4 modules may be configured for alien DWDM type."
DEFVAL { native }
::= { olPortEntry 10 }
olPortGrid OBJECT-TYPE
SYNTAX INTEGER { ghz100 (1),
ghz50 (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The DWDM grid spacing on the port."
DEFVAL { ghz100 }
::= { olPortEntry 11 }
olPortWavelength OBJECT-TYPE
SYNTAX FixedX100
UNITS "nanometers/100"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The wavelength of the channel carried by the port.
This object exists only in table entries for channel
ports on Mux/Demux modules."
::= { olPortEntry 12 }
olPortFrequency OBJECT-TYPE
SYNTAX FixedX100
UNITS "terahertz/100"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The frequency of the channel carried by the port.
This object exists only in table entries for channel
ports on Mux/Demux modules."
::= { olPortEntry 13 }
olPortOperStatus OBJECT-TYPE
SYNTAX OperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The reported operational status of the optical layer port."
::= { olPortEntry 14 }
olPortOperStatQlfr OBJECT-TYPE
SYNTAX OperStatQlfr
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is a textual list of qualifiers about the reported
operational status of the optical layer port."
::= { olPortEntry 15 }
olPortRemoteId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Identifies the remote node and port to which the
optical layer port is connected, in the format
prescribed by the PSM network management system."
DEFVAL { "" }
::= { olPortEntry 16 }
olPortExpCnxDegree OBJECT-TYPE
SYNTAX INTEGER (2..4)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The expected degree number of the equipment that is
inter-connected on the port."
::= { olPortEntry 17 }
olPortActCnxDegree OBJECT-TYPE
SYNTAX INTEGER (2..4)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The actual degree number of the equipment that is
inter-connected on the port."
::= { olPortEntry 18 }
olPortRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries
in the Optical Layer Port table. Manual creation and
deletion is supported only for the client 2 port on
ROB packs assigned to a Channel-equalizing Terminal
or Reconfigurable Add/Drop node group."
::= { olPortEntry 100 }
------------------------------------------------------------------------
-- The equipment connection table lists all intra-group optical fiber
-- patch connections that must be in place to inter-connect equipment
-- modules assigned to optical layer groupings.
------------------------------------------------------------------------
eqptConnTable OBJECT-TYPE
SYNTAX SEQUENCE OF EqptConnEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table lists all intra-group optical fiber patch
connections between ports on equipment modules assigned
to optical layer groupings."
::= { opticalLayer 5 }
eqptConnEntry OBJECT-TYPE
SYNTAX EqptConnEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the equipment connection
table."
INDEX { eqptConnSrcCpTypeIdx, -- Source CP Type
eqptConnSrcShelfIdx, -- Source Shelf Num
eqptConnSrcSlotIdx, -- Source Slot Num
eqptConnSrcPortTypeIdx, -- Source Port Type
eqptConnSrcIdx, -- Source Port Num
eqptConnDstCpTypeIdx, -- Destination CP Type
eqptConnDstShelfIdx, -- Destination Shelf Num
eqptConnDstSlotIdx, -- Destination Slot Num
eqptConnDstPortTypeIdx, -- Destination Port Type
eqptConnDstIdx } -- Destination Port Num
::= { eqptConnTable 1 }
EqptConnEntry ::= SEQUENCE { eqptConnSrcCpTypeIdx CpType,
eqptConnSrcShelfIdx INTEGER,
eqptConnSrcSlotIdx INTEGER,
eqptConnSrcPortTypeIdx OlPortType,
eqptConnSrcIdx INTEGER,
eqptConnDstCpTypeIdx CpType,
eqptConnDstShelfIdx INTEGER,
eqptConnDstSlotIdx INTEGER,
eqptConnDstPortTypeIdx OlPortType,
eqptConnDstIdx INTEGER,
eqptConnType INTEGER,
eqptConnRowStatus RowStatus }
eqptConnSrcCpTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of circuit pack on which the source port
of the equipment connection is located."
::= { eqptConnEntry 1 }
eqptConnSrcShelfIdx OBJECT-TYPE
SYNTAX INTEGER (0|1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the source port
of the equipment connection is located."
::= { eqptConnEntry 2 }
eqptConnSrcSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot on which the source port
of the equipment connection is located."
::= { eqptConnEntry 3 }
eqptConnSrcPortTypeIdx OBJECT-TYPE
SYNTAX OlPortType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of the source port of the equipment connection,
according to the function it provides."
::= { eqptConnEntry 4 }
eqptConnSrcIdx OBJECT-TYPE
SYNTAX INTEGER (1..600)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the specified port type
of the source port of the equipment connection."
::= { eqptConnEntry 5 }
eqptConnDstCpTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of circuit pack on which the destination port
of the equipment connection is located."
::= { eqptConnEntry 6 }
eqptConnDstShelfIdx OBJECT-TYPE
SYNTAX INTEGER (0|1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the destination port
of the equipment connection is located."
::= { eqptConnEntry 7 }
eqptConnDstSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot on which the destination port
of the equipment connection is located."
::= { eqptConnEntry 8 }
eqptConnDstPortTypeIdx OBJECT-TYPE
SYNTAX OlPortType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of the destination port of the equipment
connection, according to the function it provides."
::= { eqptConnEntry 9 }
eqptConnDstIdx OBJECT-TYPE
SYNTAX INTEGER (1..600)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the specified port type
of the destination port of the equipment connection."
::= { eqptConnEntry 10 }
eqptConnType OBJECT-TYPE
SYNTAX INTEGER { duplex (1),
loopback (2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The type of optical fiber patch cable for the equipment
connection entry."
::= { eqptConnEntry 11 }
eqptConnRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The equipment connection table RowStatus object is not
readable or writeable because all entries in the table
are automatically created and deleted as equipment
modules are assigned and unassigned to optical layer
groupings. This equipment connection row status object
is used only in database change notifications to
indicate if the row has been created or deleted."
::= { eqptConnEntry 100 }
------------------------------------------------------------------------
-- The Optical Layer OSC table is used to configure and monitor OSC
-- managed objects on optical layer equipment modules.
------------------------------------------------------------------------
olOSCTable OBJECT-TYPE
SYNTAX SEQUENCE OF OlOSCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table lists all OSC managed objects that have
been created on the optical layer equipment modules."
::= { opticalLayer 6 }
olOSCEntry OBJECT-TYPE
SYNTAX OlOSCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the optical laye OSC table."
INDEX { olOSCCpTypeIdx, -- CP Type
olOSCShelfIdx, -- Shelf Num
olOSCSlotIdx, -- Slot Num
olOSCLineIdx } -- Line Num
::= { olOSCTable 1 }
OlOSCEntry ::= SEQUENCE { olOSCCpTypeIdx CpType,
olOSCShelfIdx INTEGER,
olOSCSlotIdx INTEGER,
olOSCLineIdx INTEGER,
olOSCAdminStatus AdminStatus,
olOSCOperStatus OperStatus,
olOSCOperStatQlfr OperStatQlfr,
olOSCAutoEnableTimer HoursAndMinutes,
olOSCActAutoEnableTimer HoursAndMinutes,
olOSCId DisplayString,
olOSCCustom1 DisplayString,
olOSCCustom2 DisplayString,
olOSCCustom3 DisplayString,
olOSCFEIMMon INTEGER,
olOSCExpFESysName DisplayString,
olOSCExpFEIPAddr IpAddress,
olOSCExpFEGrp INTEGER,
olOSCExpFEDegr INTEGER,
olOSCFESysName DisplayString,
olOSCFEIPAddr IpAddress,
olOSCFEGrp INTEGER,
olOSCFEDegr INTEGER,
olOSCFEGrpType OlGroupType,
olOSCRowStatus RowStatus }
olOSCCpTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of circuit pack on which the OSC is located."
::= { olOSCEntry 1 }
olOSCShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf in which the OSC is located."
::= { olOSCEntry 2 }
olOSCSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot in which the OSC is located."
::= { olOSCEntry 3 }
olOSCLineIdx OBJECT-TYPE
SYNTAX INTEGER (1)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The line number of the OSC."
::= { olOSCEntry 4 }
olOSCAdminStatus OBJECT-TYPE
SYNTAX AdminStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The administrative status of the OSC. The default value
is autoEnabled if the supporting equipment is enabled
or autoEnabled, otherwise it is disabled."
::= { olOSCEntry 5 }
olOSCOperStatus OBJECT-TYPE
SYNTAX OperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The reported operational status of the OSC."
::= { olOSCEntry 6 }
olOSCOperStatQlfr OBJECT-TYPE
SYNTAX OperStatQlfr
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is a textual list of qualifiers about the reported
operational status of the OSC."
::= { olOSCEntry 7 }
olOSCAutoEnableTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies the auto-enable timer for the targeted OSC.
This value only applies if the olOSCAdminStatus object
is set to autoEnabled, in which case the default value is
008-00, otherwise, it is 000-00."
::= { olOSCEntry 8 }
olOSCActAutoEnableTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the time remaining on the auto-enable timer if
it is actively counting down. Otherwise, the value returned
is 000-00."
::= { olOSCEntry 9 }
olOSCId OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Textual data recorded by the user to briefly identify the
OSC object in a manner useful to the user."
DEFVAL { "" }
::= { olOSCEntry 10 }
olOSCCustom1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { olOSCEntry 11 }
olOSCCustom2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { olOSCEntry 12 }
olOSCCustom3 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { olOSCEntry 13 }
olOSCFEIMMon OBJECT-TYPE
SYNTAX INTEGER { enabled (1),
disabled (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object is used to control the monitoring of the Far
End Node Mismatch Identifier condition. When enabled, the
received far-end node identification attributes will be
monitored and compared to the expected far-end node
identification attribites, and a condition is raised if
attributes do no match."
DEFVAL { disabled }
::= { olOSCEntry 14 }
olOSCExpFESysName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The expected far-end node system identifier."
DEFVAL { "" }
::= { olOSCEntry 15 }
olOSCExpFEIPAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The expected far-end node IP address."
DEFVAL { 0 }
::= { olOSCEntry 16 }
olOSCExpFEGrp OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The expected far-end node optical layer group number."
DEFVAL { 0 }
::= { olOSCEntry 17 }
olOSCExpFEDegr OBJECT-TYPE
SYNTAX INTEGER (0..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The expected far-end node optical layer degree number."
DEFVAL { 0 }
::= { olOSCEntry 18 }
olOSCFESysName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The actual far-end node system identifier."
::= { olOSCEntry 19 }
olOSCFEIPAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The actual far-end node IP address."
::= { olOSCEntry 20 }
olOSCFEGrp OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The actual far-end node optical layer group number."
::= { olOSCEntry 21 }
olOSCFEDegr OBJECT-TYPE
SYNTAX INTEGER (0..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The actual far-end node optical layer degree number."
::= { olOSCEntry 22 }
olOSCFEGrpType OBJECT-TYPE
SYNTAX OlGroupType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The actual far-end node optical layer group
configuration type."
::= { olOSCEntry 23 }
olOSCRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The Optical Layer OSC table RowStatus object is not
readable or writeable because all entries in the table
are automatically created and deleted when the
supporting DLA or ROB equipment is provisioned. This
optical layer OSC row status object is used only in
database change notifications to indicate if the
row has been created or deleted."
::= { olOSCEntry 100 }
------------------------------------------------------------------------
-- The ODCC table is used to provision and administer the OSC data
-- communications channel on an optical layer OSC object which is used
-- for management communications.
------------------------------------------------------------------------
odccTable OBJECT-TYPE
SYNTAX SEQUENCE OF OdccEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table lists all provisioned ODCC objects on
equipment modules assigned to optical layer groupings."
::= { opticalLayer 7 }
odccEntry OBJECT-TYPE
SYNTAX OdccEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the ODCC table."
INDEX { odccCpTypeIdx, -- CP Type
odccShelfIdx, -- Shelf Num
odccSlotIdx, -- Slot Num
odccLineIdx } -- Line Num
::= { odccTable 1 }
OdccEntry ::= SEQUENCE { odccCpTypeIdx CpType,
odccShelfIdx INTEGER,
odccSlotIdx INTEGER,
odccLineIdx INTEGER,
odccAdminStatus AdminStatus,
odccRowStatus RowStatus }
odccCpTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of circuit pack on which the ODCC is located."
::= { odccEntry 1 }
odccShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf in which the ODCC is located."
::= { odccEntry 2 }
odccSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot in which the ODC is located."
::= { odccEntry 3 }
odccLineIdx OBJECT-TYPE
SYNTAX INTEGER (1)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The line number of the ODCC."
::= { odccEntry 4 }
odccAdminStatus OBJECT-TYPE
SYNTAX AdminStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The administrative status of the ODCC. The default value
is disabled if the supporting ODC is disabled, otherwise
it is enabled."
::= { odccEntry 5 }
odccRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
ODCC table, which in turn controls the provisioning
and de-provisioning of ODCC objects."
::= { odccEntry 100 }
------------------------------------------------------------------------
-- The WDM table is used to configure and monitor WDM managed
-- objects on equipment modules assigned to optical layer groupings.
------------------------------------------------------------------------
wdmTable OBJECT-TYPE
SYNTAX SEQUENCE OF WdmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table lists all WDM managed objects that
have been created on optical layer equipment."
::= { opticalLayer 8 }
wdmEntry OBJECT-TYPE
SYNTAX WdmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the WDM table."
INDEX { wdmCpTypeIdx, -- CP Type
wdmShelfIdx, -- Shelf Num
wdmSlotIdx, -- Slot Num
wdmLineIdx } -- Line Num
::= { wdmTable 1 }
WdmEntry ::= SEQUENCE { wdmCpTypeIdx CpType,
wdmShelfIdx INTEGER,
wdmSlotIdx INTEGER,
wdmLineIdx INTEGER,
wdmAdminStatus AdminStatus,
wdmOperStatus OperStatus,
wdmOperStatQlfr OperStatQlfr,
wdmAutoEnableTimer HoursAndMinutes,
wdmActAutoEnableTimer HoursAndMinutes,
wdmId DisplayString,
wdmCustom1 DisplayString,
wdmCustom2 DisplayString,
wdmCustom3 DisplayString,
wdmFiberType INTEGER,
wdmSpanLength Unsigned32,
wdmSpanLossRxHighTh FixedX10,
wdmSpanLossSpecMax FixedX10,
wdmNumChannels INTEGER,
wdmRowStatus RowStatus }
wdmCpTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of circuit pack on which the WDM is located."
::= { wdmEntry 1 }
wdmShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf in which the WDM is located."
::= { wdmEntry 2 }
wdmSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot in which the WDM is located."
::= { wdmEntry 3 }
wdmLineIdx OBJECT-TYPE
SYNTAX INTEGER (1)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The line number of the WDM."
::= { wdmEntry 4 }
wdmAdminStatus OBJECT-TYPE
SYNTAX AdminStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The administrative status of the WDM. The default value
is autoEnabled if the supporting equipment is enabled
or autoEnabled, otherwise it is disabled."
::= { wdmEntry 5 }
wdmOperStatus OBJECT-TYPE
SYNTAX OperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The reported operational status of the WDM."
::= { wdmEntry 6 }
wdmOperStatQlfr OBJECT-TYPE
SYNTAX OperStatQlfr
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is a textual list of qualifiers about the reported
operational status of the WDM."
::= { wdmEntry 7 }
wdmAutoEnableTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies the auto-enable timer for the targeted WDM.
This value only applies if the wdmAdminStatus object
is set to autoEnabled, in which case the default value is
008-00, otherwise, it is 000-00."
::= { wdmEntry 8 }
wdmActAutoEnableTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the time remaining on the auto-enable timer if
it is actively counting down. Otherwise, the value returned
is 000-00."
::= { wdmEntry 9 }
wdmId OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Textual data recorded by the user to briefly identify the
WDM object in a manner useful to the user."
DEFVAL { "" }
::= { wdmEntry 10 }
wdmCustom1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { wdmEntry 11 }
wdmCustom2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { wdmEntry 12 }
wdmCustom3 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { wdmEntry 13 }
wdmFiberType OBJECT-TYPE
SYNTAX INTEGER { smf (1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The fiber type of the span fiber."
DEFVAL { smf }
::= { wdmEntry 14 }
wdmSpanLength OBJECT-TYPE
SYNTAX Unsigned32
UNITS "kilometers"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The measured length of the receive span fiber."
::= { wdmEntry 15 }
wdmSpanLossRxHighTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The high threshold setting for the loss on the receive
fiber of the Line span. The setting for this object is
used to evaluate the olPortLossRxHighThCond trap. When
the value of this object is set to 0, the
olPortLossRxHighThCond trap is disabled."
::= { wdmEntry 16 }
wdmSpanLossSpecMax OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The specified maximum supported loss on the Line span.
The value of this object is dependent on the optical
layer group configurations of the local and far-end nodes."
::= { wdmEntry 17 }
wdmNumChannels OBJECT-TYPE
SYNTAX INTEGER (0..44)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The actual number of channels that the WDM is currently
provisioned to carry."
::= { wdmEntry 18 }
wdmRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The WDM table RowStatus object is not readable or
writeable because all entries in the table are
automatically created and deleted when the supporting
DLA or ROB circuit pack is assigned and unassigned
to an optical layer grouping. This WDM row status
object is used only in database change notifications
to indicate if the row has been created or deleted."
::= { wdmEntry 100 }
------------------------------------------------------------------------
-- The Wavelength Channel Cross Connection table is used to provision
-- and retrieve wavelength channel cross-connections. Wavelength channel
-- cross-connections are configured to route add/drop and pass-through
-- optical channels through ROB-equipped optical layer groupings.
------------------------------------------------------------------------
wchXCTable OBJECT-TYPE
SYNTAX SEQUENCE OF WchXCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table lists all configured wavelength channel
cross-connections configured on optical layer equipment."
::= { opticalLayer 9 }
wchXCEntry OBJECT-TYPE
SYNTAX WchXCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the wavelength channel
cross-connection table."
INDEX { wchXCSrcCpTypeIdx, -- Source CP Type
wchXCSrcShelfIdx, -- Source Shelf Num
wchXCSrcSlotIdx, -- Source Slot Num
wchXCSrcPortTypeIdx, -- Source Port Type
wchXCSrcPortIdx, -- Source Port Num
wchXCSrcChannelIdx, -- Source Channel Num
wchXCDstCpTypeIdx, -- Destination CP Type
wchXCDstShelfIdx, -- Destination Shelf Num
wchXCDstSlotIdx, -- Destination Slot Num
wchXCDstPortTypeIdx, -- Destination Port Type
wchXCDstPortIdx, -- Destination Port Num
wchXCDstChannelIdx } -- Destination Channel Num
::= { wchXCTable 1 }
WchXCEntry ::= SEQUENCE { wchXCSrcCpTypeIdx CpType,
wchXCSrcShelfIdx INTEGER,
wchXCSrcSlotIdx INTEGER,
wchXCSrcPortTypeIdx OlPortType,
wchXCSrcPortIdx INTEGER,
wchXCSrcChannelIdx INTEGER,
wchXCDstCpTypeIdx CpType,
wchXCDstShelfIdx INTEGER,
wchXCDstSlotIdx INTEGER,
wchXCDstPortTypeIdx OlPortType,
wchXCDstPortIdx INTEGER,
wchXCDstChannelIdx INTEGER,
wchXCServiceName DisplayString,
wchXCRowStatus RowStatus }
wchXCSrcCpTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of circuit pack on which the source wavelength
channel of the cross-connection is located."
::= { wchXCEntry 1 }
wchXCSrcShelfIdx OBJECT-TYPE
SYNTAX INTEGER (0|1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the source wavelength
channel of the cross-connection is located."
::= { wchXCEntry 2 }
wchXCSrcSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot on which the source wavelength
channel of the cross-connection is located."
::= { wchXCEntry 3 }
wchXCSrcPortTypeIdx OBJECT-TYPE
SYNTAX OlPortType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of port on which the source wavelength channel
of the cross-connection is located."
::= { wchXCEntry 4 }
wchXCSrcPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..600)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on which the source wavelength channel
of the cross-connection is located."
::= { wchXCEntry 5 }
wchXCSrcChannelIdx OBJECT-TYPE
SYNTAX INTEGER (135..610)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The channel number of the source wavelength channel of the
cross-connection."
::= { wchXCEntry 6 }
wchXCDstCpTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of circuit pack on which the destination wavelength
channel of the cross-connection is located."
::= { wchXCEntry 7 }
wchXCDstShelfIdx OBJECT-TYPE
SYNTAX INTEGER (0|1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the destination wavelength
channel of the cross-connection is located."
::= { wchXCEntry 8 }
wchXCDstSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot on which the destination wavelength
channel of the cross-connection is located."
::= { wchXCEntry 9 }
wchXCDstPortTypeIdx OBJECT-TYPE
SYNTAX OlPortType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of port on which the destination wavelength channel
of the cross-connection is located."
::= { wchXCEntry 10 }
wchXCDstPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..600)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on which the destination wavelength
channel of the cross-connection is located."
::= { wchXCEntry 11 }
wchXCDstChannelIdx OBJECT-TYPE
SYNTAX INTEGER (135..610)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The channel number of the destination wavelength channel
of the cross-connection."
::= { wchXCEntry 12 }
wchXCServiceName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Name of end-to-end wavelength service of which this cross-
connection is a part."
DEFVAL { "" }
::= { wchXCEntry 13 }
wchXCRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries
in the wavelength channel cross-connection table."
::= { wchXCEntry 100 }
------------------------------------------------------------------------
-- The Wavelength Channel table is used to manage wavelength channel
-- objects which support provisioned wavelength channel cross-connections.
------------------------------------------------------------------------
wchTable OBJECT-TYPE
SYNTAX SEQUENCE OF WchEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table lists all managed wavelength channels on
equipment modules assigned to optical layer groupings."
::= { opticalLayer 10 }
wchEntry OBJECT-TYPE
SYNTAX WchEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the wavelength channel
table."
INDEX { wchCpTypeIdx, -- CP Type
wchShelfIdx, -- Shelf Num
wchSlotIdx, -- Slot Num
wchPortTypeIdx, -- Port Type
wchPortIdx, -- Port Num
wchIdx } -- Channel Num
::= { wchTable 1 }
WchEntry ::= SEQUENCE { wchCpTypeIdx CpType,
wchShelfIdx INTEGER,
wchSlotIdx INTEGER,
wchPortTypeIdx OlPortType,
wchPortIdx INTEGER,
wchIdx INTEGER,
wchAdminStatus AdminStatus,
wchOperStatus OperStatus,
wchOperStatQlfr OperStatQlfr,
wchAutoEnableTimer HoursAndMinutes,
wchActAutoEnableTimer HoursAndMinutes,
wchId DisplayString,
wchCustom1 DisplayString,
wchCustom2 DisplayString,
wchCustom3 DisplayString,
wchBitrate INTEGER,
wchGrid INTEGER,
wchWavelength FixedX100,
wchFrequency FixedX100,
wchRowStatus RowStatus }
wchCpTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of circuit pack on which the wavelength channel
is located."
::= { wchEntry 1 }
wchShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the wavelength channel
is located."
::= { wchEntry 2 }
wchSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot on which the wavelength channel
is located."
::= { wchEntry 3 }
wchPortTypeIdx OBJECT-TYPE
SYNTAX OlPortType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of port on which the wavelength channel is
located."
::= { wchEntry 4 }
wchPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on which the wavelength channel
is located."
::= { wchEntry 5 }
wchIdx OBJECT-TYPE
SYNTAX INTEGER (135..610)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the targeted wavelength channel."
::= { wchEntry 6 }
wchAdminStatus OBJECT-TYPE
SYNTAX AdminStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The administrative status of the wavelength channel.
The default value is autoEnabled if the supporting WDM
is enabled or autoEnabled, otherwise it is disabled."
::= { wchEntry 7 }
wchOperStatus OBJECT-TYPE
SYNTAX OperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The reported operational status of the wavelength channel."
::= { wchEntry 8 }
wchOperStatQlfr OBJECT-TYPE
SYNTAX OperStatQlfr
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is a textual list of qualifiers about the reported
operational status of the wavelength channel."
::= { wchEntry 9 }
wchAutoEnableTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies the auto-enable timer for the targeted wavelength
channel. This value only applies if the wchAdminStatus object
is set to autoEnabled, in which case the default value is
008-00, otherwise, it is 000-00."
::= { wchEntry 10 }
wchActAutoEnableTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the time remaining on the auto-enable timer if
it is actively counting down. Otherwise, the value returned
is 000-00."
::= { wchEntry 11 }
wchId OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Textual data recorded by the user to briefly identify the
wavelength channel object in a manner useful to the user."
DEFVAL { "" }
::= { wchEntry 12 }
wchCustom1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { wchEntry 13 }
wchCustom2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { wchEntry 14 }
wchCustom3 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { wchEntry 15 }
wchBitrate OBJECT-TYPE
SYNTAX INTEGER { tenGig (1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The bitrate of the signal carried by the wavelength channel.
A value of tenGig applies to all signal bitrates of
10Gb/sec or less."
DEFVAL { tenGig }
::= { wchEntry 16 }
wchGrid OBJECT-TYPE
SYNTAX INTEGER { ghz100 (1),
ghz50 (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The minimum grid spacing with which the channel is compatible."
DEFVAL { ghz100 }
::= { wchEntry 17 }
wchWavelength OBJECT-TYPE
SYNTAX FixedX100
UNITS "nanometers/100"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The wavelength of the channel."
::= { wchEntry 18 }
wchFrequency OBJECT-TYPE
SYNTAX FixedX100
UNITS "terahertz/100"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The frequency of the channel."
::= { wchEntry 19 }
wchRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The Wavelength Channel table RowStatus object is not readable or
writeable because all entries in the Wavelength Channel table are
automatically created and deleted when an wavelength channel
cross-connection involving the wavelength channel is created or
deleted. This Wavelength Channel row status object is used only
in database change notifications to indicate if the row has
been created or deleted."
::= { wchEntry 100 }
------------------------------------------------------------------------
-- The objects of the Optical Layer Group Merge branch are used to invoke
-- an optical layer group merge operation.
------------------------------------------------------------------------
olGroupMerge OBJECT IDENTIFIER ::= { opticalLayer 11 }
olGroupMergeCmd OBJECT-TYPE
SYNTAX INTEGER { idle (1),
invoke (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object is used to invoke an optical layer group
merge operation. The optical layer group merge is
activated when this object is set to invoke(2). The
values of the olGroupMergePrimary and olGroupMergeSecondary
objects must be set in the same set request as this object.
When a get is performed on this object, the value returned
is idle(1)."
::= { olGroupMerge 1 }
olGroupMergePrimary OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The identifier of the primary optical layer group
of the merge."
::= { olGroupMerge 2 }
olGroupMergeSecondary OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The identifier of the secondary optical layer group
of the merge."
::= { olGroupMerge 3 }
------------------------------------------------------------------------
-- The Optical Layer Performance branch contains all tables used to
-- access performance monitoring measurements and configuration for
-- monitored optical layer objects.
------------------------------------------------------------------------
olPerformance OBJECT IDENTIFIER ::= { opticalLayer 12 }
-----------------------------------------------------------------------
-- Objects used to retrieve current optical layer OSC
-- Performance Monitoring statistics.
-----------------------------------------------------------------------
olOSCCrntPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF OlOSCCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of current performance monitoring statistics
collected for the optical layer OSC objects on the NE."
::= { olPerformance 1 }
olOSCCrntPMEntry OBJECT-TYPE
SYNTAX OlOSCCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the optical layer OSC current
performance monitoring table. Each row of this table
contains a full set of PM statistics and related data
for a current measurement interval for a given optical
layer OSC object."
INDEX { olOSCCrntPMCpTypeIdx,
olOSCCrntPMShelfIdx,
olOSCCrntPMSlotIdx,
olOSCCrntPMLineIdx,
olOSCCrntPMIntervalTypeIdx }
::= { olOSCCrntPMTable 1 }
OlOSCCrntPMEntry ::= SEQUENCE { olOSCCrntPMCpTypeIdx CpType,
olOSCCrntPMShelfIdx INTEGER,
olOSCCrntPMSlotIdx INTEGER,
olOSCCrntPMLineIdx INTEGER,
olOSCCrntPMIntervalTypeIdx PMIntervalType,
olOSCCrntPMOPRValue FixedX10,
olOSCCrntPMOPRTimeStamp DateAndTime,
olOSCCrntPMOPRValidity PMValidity,
olOSCCrntPMOPTValue FixedX10,
olOSCCrntPMOPTTimeStamp DateAndTime,
olOSCCrntPMOPTValidity PMValidity,
olOSCCrntPMOBRValue FixedX10,
olOSCCrntPMOBRTimeStamp DateAndTime,
olOSCCrntPMOBRValidity PMValidity,
olOSCCrntPMCVSValue Unsigned32,
olOSCCrntPMCVSTimeStamp DateAndTime,
olOSCCrntPMCVSValidity PMValidity,
olOSCCrntPMCVSInitialize InitializeCmd,
olOSCCrntPMESSValue Unsigned32,
olOSCCrntPMESSTimeStamp DateAndTime,
olOSCCrntPMESSValidity PMValidity,
olOSCCrntPMESSInitialize InitializeCmd,
olOSCCrntPMSESSValue Unsigned32,
olOSCCrntPMSESSTimeStamp DateAndTime,
olOSCCrntPMSESSValidity PMValidity,
olOSCCrntPMSESSInitialize InitializeCmd,
olOSCCrntPMSEFSSValue Unsigned32,
olOSCCrntPMSEFSSTimeStamp DateAndTime,
olOSCCrntPMSEFSSValidity PMValidity,
olOSCCrntPMSEFSSInitialize InitializeCmd,
olOSCCrntPMUASSValue Unsigned32,
olOSCCrntPMUASSTimeStamp DateAndTime,
olOSCCrntPMUASSValidity PMValidity,
olOSCCrntPMUASSInitialize InitializeCmd }
olOSCCrntPMCpTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of circuit pack on which the optical layer OSC
targeted for PMs is located."
::= { olOSCCrntPMEntry 1 }
olOSCCrntPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf in which the optical layer OSC
targeted for PMs is located."
::= { olOSCCrntPMEntry 2 }
olOSCCrntPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot in which the optical layer OSC
targeted for PMs is located."
::= { olOSCCrntPMEntry 3 }
olOSCCrntPMLineIdx OBJECT-TYPE
SYNTAX INTEGER (1)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The line number of the OSC targeted for PMs."
::= { olOSCCrntPMEntry 4 }
olOSCCrntPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { olOSCCrntPMEntry 5 }
olOSCCrntPMOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The OSC optical power received on the Line port."
::= { olOSCCrntPMEntry 6 }
olOSCCrntPMOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power received value."
::= { olOSCCrntPMEntry 7 }
olOSCCrntPMOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power received
value."
::= { olOSCCrntPMEntry 8 }
olOSCCrntPMOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The OSC optical power transmitted at the output of the
Line port."
::= { olOSCCrntPMEntry 9 }
olOSCCrntPMOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power transmitted
value."
::= { olOSCCrntPMEntry 10 }
olOSCCrntPMOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power
transmitted value."
::= { olOSCCrntPMEntry 11 }
olOSCCrntPMOBRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The OSC optical back-reflected power."
::= { olOSCCrntPMEntry 12 }
olOSCCrntPMOBRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical back-reflected
power value."
::= { olOSCCrntPMEntry 13 }
olOSCCrntPMOBRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical back-reflected
power value."
::= { olOSCCrntPMEntry 14 }
olOSCCrntPMCVSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of coding violations at the section layer of
the received OSC signal."
::= { olOSCCrntPMEntry 15 }
olOSCCrntPMCVSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer coding violations
value."
::= { olOSCCrntPMEntry 16 }
olOSCCrntPMCVSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer coding
violations value."
::= { olOSCCrntPMEntry 17 }
olOSCCrntPMCVSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the olOSCCrntPMCVSValue object
to 0."
::= { olOSCCrntPMEntry 18 }
olOSCCrntPMESSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of errored seconds at the section layer of
the received OSC signal."
::= { olOSCCrntPMEntry 19 }
olOSCCrntPMESSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer errored seconds
value."
::= { olOSCCrntPMEntry 20 }
olOSCCrntPMESSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer errored
seconds value."
::= { olOSCCrntPMEntry 21 }
olOSCCrntPMESSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the olOSCCrntPMESSValue object
to 0."
::= { olOSCCrntPMEntry 22 }
olOSCCrntPMSESSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of severely errored seconds at the section layer
of the received OSC signal."
::= { olOSCCrntPMEntry 23 }
olOSCCrntPMSESSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer severely errored
seconds value."
::= { olOSCCrntPMEntry 24 }
olOSCCrntPMSESSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer severely
errored seconds value."
::= { olOSCCrntPMEntry 25 }
olOSCCrntPMSESSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the olOSCCrntPMSESSValue object
to 0."
::= { olOSCCrntPMEntry 26 }
olOSCCrntPMSEFSSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of severely errored framing seconds at the section
layer of the received OSC signal."
::= { olOSCCrntPMEntry 27 }
olOSCCrntPMSEFSSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer severely errored
framing seconds value."
::= { olOSCCrntPMEntry 28 }
olOSCCrntPMSEFSSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer severely
errored framing seconds value."
::= { olOSCCrntPMEntry 29 }
olOSCCrntPMSEFSSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the olOSCCrntPMSEFSSValue object
to 0."
::= { olOSCCrntPMEntry 30 }
olOSCCrntPMUASSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of unavailable seconds at the section layer
of the received OSC signal."
::= { olOSCCrntPMEntry 31 }
olOSCCrntPMUASSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer unavailable
seconds value."
::= { olOSCCrntPMEntry 32 }
olOSCCrntPMUASSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer unavailable
seconds value."
::= { olOSCCrntPMEntry 33 }
olOSCCrntPMUASSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the olOSCCrntPMUASSValue
object to 0."
::= { olOSCCrntPMEntry 34 }
-----------------------------------------------------------------------
-- Objects used to retrieve historical Optical Layer OSC
-- Performance Monitoring statistics.
-----------------------------------------------------------------------
olOSCHistPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF OlOSCHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of historical performance monitoring statistics
collected for the optical layer OSC objects on the NE."
::= { olPerformance 2 }
olOSCHistPMEntry OBJECT-TYPE
SYNTAX OlOSCHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the optical layer OSC historical
performance monitoring table. Each row of this table
contains a full set of PM statistics and related data
for a historical measurement interval for a given optical
layer OSC object."
INDEX { olOSCHistPMCpTypeIdx,
olOSCHistPMShelfIdx,
olOSCHistPMSlotIdx,
olOSCHistPMLineIdx,
olOSCHistPMIntervalTypeIdx,
olOSCHistPMIntervalIdx }
::= { olOSCHistPMTable 1 }
OlOSCHistPMEntry ::= SEQUENCE { olOSCHistPMCpTypeIdx CpType,
olOSCHistPMShelfIdx INTEGER,
olOSCHistPMSlotIdx INTEGER,
olOSCHistPMLineIdx INTEGER,
olOSCHistPMIntervalTypeIdx PMIntervalType,
olOSCHistPMIntervalIdx INTEGER,
olOSCHistPMOPRValue FixedX10,
olOSCHistPMOPRTimeStamp DateAndTime,
olOSCHistPMOPRValidity PMValidity,
olOSCHistPMOPTValue FixedX10,
olOSCHistPMOPTTimeStamp DateAndTime,
olOSCHistPMOPTValidity PMValidity,
olOSCHistPMOBRValue FixedX10,
olOSCHistPMOBRTimeStamp DateAndTime,
olOSCHistPMOBRValidity PMValidity,
olOSCHistPMCVSValue Unsigned32,
olOSCHistPMCVSTimeStamp DateAndTime,
olOSCHistPMCVSValidity PMValidity,
olOSCHistPMCVSInitialize InitializeCmd,
olOSCHistPMESSValue Unsigned32,
olOSCHistPMESSTimeStamp DateAndTime,
olOSCHistPMESSValidity PMValidity,
olOSCHistPMESSInitialize InitializeCmd,
olOSCHistPMSESSValue Unsigned32,
olOSCHistPMSESSTimeStamp DateAndTime,
olOSCHistPMSESSValidity PMValidity,
olOSCHistPMSESSInitialize InitializeCmd,
olOSCHistPMSEFSSValue Unsigned32,
olOSCHistPMSEFSSTimeStamp DateAndTime,
olOSCHistPMSEFSSValidity PMValidity,
olOSCHistPMSEFSSInitialize InitializeCmd,
olOSCHistPMUASSValue Unsigned32,
olOSCHistPMUASSTimeStamp DateAndTime,
olOSCHistPMUASSValidity PMValidity,
olOSCHistPMUASSInitialize InitializeCmd }
olOSCHistPMCpTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of circuit pack on which the optical layer OSC
targeted for PMs is located."
::= { olOSCHistPMEntry 1 }
olOSCHistPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf in which the optical layer OSC
targeted for PMs is located."
::= { olOSCHistPMEntry 2 }
olOSCHistPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot in which the optical layer OSC
targeted for PMs is located."
::= { olOSCHistPMEntry 3 }
olOSCHistPMLineIdx OBJECT-TYPE
SYNTAX INTEGER (1)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The line number of the OSC targeted for PMs."
::= { olOSCHistPMEntry 4 }
olOSCHistPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { olOSCHistPMEntry 5 }
olOSCHistPMIntervalIdx OBJECT-TYPE
SYNTAX INTEGER (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific PM bin number. The range is 1 to 96 for the
15-minute historical bins. For the 1-day historical bin, the
value is 1."
::= { olOSCHistPMEntry 6 }
olOSCHistPMOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The OSC optical power received on the Line port."
::= { olOSCHistPMEntry 7 }
olOSCHistPMOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power received value."
::= { olOSCHistPMEntry 8 }
olOSCHistPMOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power received
value."
::= { olOSCHistPMEntry 9 }
olOSCHistPMOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The OSC optical power transmitted at the output of the
Line port."
::= { olOSCHistPMEntry 10 }
olOSCHistPMOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power transmitted
value."
::= { olOSCHistPMEntry 11 }
olOSCHistPMOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power
transmitted value."
::= { olOSCHistPMEntry 12 }
olOSCHistPMOBRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The OSC optical back-reflected power."
::= { olOSCHistPMEntry 13 }
olOSCHistPMOBRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical back-reflected
power value."
::= { olOSCHistPMEntry 14 }
olOSCHistPMOBRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical back-reflected
power value."
::= { olOSCHistPMEntry 15 }
olOSCHistPMCVSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of coding violations at the section layer of
the received OSC signal."
::= { olOSCHistPMEntry 16 }
olOSCHistPMCVSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer coding violations
value."
::= { olOSCHistPMEntry 17 }
olOSCHistPMCVSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer coding
violations value."
::= { olOSCHistPMEntry 18 }
olOSCHistPMCVSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the olOSCHistPMCVSValue object
to 0."
::= { olOSCHistPMEntry 19 }
olOSCHistPMESSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of errored seconds at the section layer of
the received OSC signal."
::= { olOSCHistPMEntry 20 }
olOSCHistPMESSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer errored seconds
value."
::= { olOSCHistPMEntry 21 }
olOSCHistPMESSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer errored
seconds value."
::= { olOSCHistPMEntry 22 }
olOSCHistPMESSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the olOSCHistPMESSValue object
to 0."
::= { olOSCHistPMEntry 23 }
olOSCHistPMSESSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of severely errored seconds at the section layer
of the received OSC signal."
::= { olOSCHistPMEntry 24 }
olOSCHistPMSESSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer severely errored
seconds value."
::= { olOSCHistPMEntry 25 }
olOSCHistPMSESSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer severely
errored seconds value."
::= { olOSCHistPMEntry 26 }
olOSCHistPMSESSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the olOSCHistPMSESSValue object
to 0."
::= { olOSCHistPMEntry 27 }
olOSCHistPMSEFSSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of severely errored framing seconds at the section
layer of the received OSC signal."
::= { olOSCHistPMEntry 28 }
olOSCHistPMSEFSSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer severely errored
framing seconds value."
::= { olOSCHistPMEntry 29 }
olOSCHistPMSEFSSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer severely
errored framing seconds value."
::= { olOSCHistPMEntry 30 }
olOSCHistPMSEFSSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the olOSCHistPMSEFSSValue object
to 0."
::= { olOSCHistPMEntry 31 }
olOSCHistPMUASSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of unavailable seconds at the section layer
of the received OSC signal."
::= { olOSCHistPMEntry 32 }
olOSCHistPMUASSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer unavailable
seconds value."
::= { olOSCHistPMEntry 33 }
olOSCHistPMUASSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer unavailable
seconds value."
::= { olOSCHistPMEntry 34 }
olOSCHistPMUASSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the olOSCHistPMUASSValue
object to 0."
::= { olOSCHistPMEntry 35 }
-----------------------------------------------------------------------
-- Objects used to manage Optical Layer OSC Performance
-- Monitoring Threshold Levels
-----------------------------------------------------------------------
olOSCPMThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF OlOSCPMThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of threshold levels for performance monitoring
counter values on Optical Layer OSC objects, that are
used in the generation of threshold crossing alerts."
::= { olPerformance 3 }
olOSCPMThresholdEntry OBJECT-TYPE
SYNTAX OlOSCPMThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the optical layer OSC performance
monitoring threshold table. Each row of this table
contains a set of PM thresholds for a given interval
type that applies to an individual optical layer OSC
object."
INDEX { olOSCPMThresholdCpTypeIdx,
olOSCPMThresholdShelfIdx,
olOSCPMThresholdSlotIdx,
olOSCPMThresholdLineIdx,
olOSCPMThresholdIntervalTypeIdx }
::= { olOSCPMThresholdTable 1 }
OlOSCPMThresholdEntry ::= SEQUENCE { olOSCPMThresholdCpTypeIdx CpType,
olOSCPMThresholdShelfIdx INTEGER,
olOSCPMThresholdSlotIdx INTEGER,
olOSCPMThresholdLineIdx INTEGER,
olOSCPMThresholdIntervalTypeIdx PMIntervalType,
olOSCPMThresholdCVSValue Unsigned32,
olOSCPMThresholdESSValue Unsigned32,
olOSCPMThresholdSESSValue Unsigned32,
olOSCPMThresholdSEFSSValue Unsigned32,
olOSCPMThresholdUASSValue Unsigned32 }
olOSCPMThresholdCpTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of circuit pack on which the optical layer
OSC targeted for PM thresholds is located."
::= { olOSCPMThresholdEntry 1 }
olOSCPMThresholdShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf in which the optical layer
OSC targeted for PM thresholds is located."
::= { olOSCPMThresholdEntry 2 }
olOSCPMThresholdSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot in which the optical layer OSC
targeted for PM thresholds is located."
::= { olOSCPMThresholdEntry 3 }
olOSCPMThresholdLineIdx OBJECT-TYPE
SYNTAX INTEGER (1)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The line number of the OSC targeted for PM thresholds."
::= { olOSCPMThresholdEntry 4 }
olOSCPMThresholdIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length. Thresholds
are supported for the 15-minute and 1-day PM bins only."
::= { olOSCPMThresholdEntry 5 }
olOSCPMThresholdCVSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of coding violations at the
section layer."
::= { olOSCPMThresholdEntry 6 }
olOSCPMThresholdESSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of errored seconds at the
section layer."
::= { olOSCPMThresholdEntry 7 }
olOSCPMThresholdSESSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of severely errored seconds at the
section layer."
::= { olOSCPMThresholdEntry 8 }
olOSCPMThresholdSEFSSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of severely errored framing
seconds at the section layer."
::= { olOSCPMThresholdEntry 9 }
olOSCPMThresholdUASSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of unavailable seconds at the
section layer."
::= { olOSCPMThresholdEntry 10 }
-----------------------------------------------------------------------
-- Objects used to retrieve current Performance Monitoring statistics
-- for Optical Layer Ports.
-----------------------------------------------------------------------
olPortCrntPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF OlPortCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of current performance monitoring statistics
collected for ports on equipment modules assigned
to optical layer groupings."
::= { olPerformance 4 }
olPortCrntPMEntry OBJECT-TYPE
SYNTAX OlPortCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the optical layer port current
performance monitoring table. Each row of this table
contains a full set of PM statistics and related data
for a current measurement interval for a given optical
layer port."
INDEX { olPortCrntPMCpTypeIdx,
olPortCrntPMShelfIdx,
olPortCrntPMSlotIdx,
olPortCrntPMTypeIdx,
olPortCrntPMIdx,
olPortCrntPMIntervalTypeIdx }
::= { olPortCrntPMTable 1 }
OlPortCrntPMEntry ::= SEQUENCE { olPortCrntPMCpTypeIdx CpType,
olPortCrntPMShelfIdx INTEGER,
olPortCrntPMSlotIdx INTEGER,
olPortCrntPMTypeIdx OlPortType,
olPortCrntPMIdx INTEGER,
olPortCrntPMIntervalTypeIdx PMIntervalType,
olPortCrntPMOPRValue FixedX10,
olPortCrntPMOPRTimeStamp DateAndTime,
olPortCrntPMOPRValidity PMValidity,
olPortCrntPMOPRMinValue FixedX10,
olPortCrntPMOPRMinTimeStamp DateAndTime,
olPortCrntPMOPRMinValidity PMValidity,
olPortCrntPMOPRMaxValue FixedX10,
olPortCrntPMOPRMaxTimeStamp DateAndTime,
olPortCrntPMOPRMaxValidity PMValidity,
olPortCrntPMOPRAvgValue FixedX10,
olPortCrntPMOPRAvgTimeStamp DateAndTime,
olPortCrntPMOPRAvgValidity PMValidity,
olPortCrntPMOPRStdDevValue FixedX10,
olPortCrntPMOPRStdDevTimeStamp DateAndTime,
olPortCrntPMOPRStdDevValidity PMValidity,
olPortCrntPMOPTValue FixedX10,
olPortCrntPMOPTTimeStamp DateAndTime,
olPortCrntPMOPTValidity PMValidity,
olPortCrntPMOPTMinValue FixedX10,
olPortCrntPMOPTMinTimeStamp DateAndTime,
olPortCrntPMOPTMinValidity PMValidity,
olPortCrntPMOPTMaxValue FixedX10,
olPortCrntPMOPTMaxTimeStamp DateAndTime,
olPortCrntPMOPTMaxValidity PMValidity,
olPortCrntPMOPTAvgValue FixedX10,
olPortCrntPMOPTAvgTimeStamp DateAndTime,
olPortCrntPMOPTAvgValidity PMValidity,
olPortCrntPMOPTStdDevValue FixedX10,
olPortCrntPMOPTStdDevTimeStamp DateAndTime,
olPortCrntPMOPTStdDevValidity PMValidity,
olPortCrntPMLossRxValue FixedX10,
olPortCrntPMLossRxTimeStamp DateAndTime,
olPortCrntPMLossRxValidity PMValidity,
olPortCrntPMLossTxValue FixedX10,
olPortCrntPMLossTxTimeStamp DateAndTime,
olPortCrntPMLossTxValidity PMValidity,
olPortCrntPMInitializeAll InitializeCmd }
olPortCrntPMCpTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of circuit pack on which the port
targeted for PMs is located."
::= { olPortCrntPMEntry 1 }
olPortCrntPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf in which the port
targeted for PMs is located."
::= { olPortCrntPMEntry 2 }
olPortCrntPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot in which the port
targeted for PMs is located."
::= { olPortCrntPMEntry 3 }
olPortCrntPMTypeIdx OBJECT-TYPE
SYNTAX OlPortType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of port targeted for PMs."
::= { olPortCrntPMEntry 4 }
olPortCrntPMIdx OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the specified
port type targeted for PMs."
::= { olPortCrntPMEntry 5 }
olPortCrntPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { olPortCrntPMEntry 6 }
olPortCrntPMOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The instantaneous optical power received on the port."
::= { olPortCrntPMEntry 7 }
olPortCrntPMOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the instantaneous optical
power received value."
::= { olPortCrntPMEntry 8 }
olPortCrntPMOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided instantaneous
optical power received value."
::= { olPortCrntPMEntry 9 }
olPortCrntPMOPRMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power received on the port over
the interval."
::= { olPortCrntPMEntry 10 }
olPortCrntPMOPRMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical
power received value."
::= { olPortCrntPMEntry 11 }
olPortCrntPMOPRMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum
optical power received value."
::= { olPortCrntPMEntry 12 }
olPortCrntPMOPRMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power received on the port over
the interval."
::= { olPortCrntPMEntry 13 }
olPortCrntPMOPRMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical
power received value."
::= { olPortCrntPMEntry 14 }
olPortCrntPMOPRMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum
optical power received value."
::= { olPortCrntPMEntry 15 }
olPortCrntPMOPRAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power received on the port over
the interval."
::= { olPortCrntPMEntry 16 }
olPortCrntPMOPRAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical
power received value."
::= { olPortCrntPMEntry 17 }
olPortCrntPMOPRAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average
optical power received value."
::= { olPortCrntPMEntry 18 }
olPortCrntPMOPRStdDevValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The standard deviation from the average of the optical
power received on the port over the interval."
::= { olPortCrntPMEntry 19 }
olPortCrntPMOPRStdDevTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the standard deviation value
for the optical power received."
::= { olPortCrntPMEntry 20 }
olPortCrntPMOPRStdDevValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided standard deviation
value for the optical power received."
::= { olPortCrntPMEntry 21 }
olPortCrntPMOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The instantaneous optical power transmitted on the port."
::= { olPortCrntPMEntry 22 }
olPortCrntPMOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the instantaneous optical
power transmitted value."
::= { olPortCrntPMEntry 23 }
olPortCrntPMOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided instantaneous
optical power transmitted value."
::= { olPortCrntPMEntry 24 }
olPortCrntPMOPTMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power transmitted on the port over
the interval."
::= { olPortCrntPMEntry 25 }
olPortCrntPMOPTMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical
power transmitted value."
::= { olPortCrntPMEntry 26 }
olPortCrntPMOPTMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum
optical power transmitted value."
::= { olPortCrntPMEntry 27 }
olPortCrntPMOPTMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power transmitted on the port over
the interval."
::= { olPortCrntPMEntry 28 }
olPortCrntPMOPTMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical
power transmitted value."
::= { olPortCrntPMEntry 29 }
olPortCrntPMOPTMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum
optical power transmitted value."
::= { olPortCrntPMEntry 30 }
olPortCrntPMOPTAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power transmitted on the port over
the interval."
::= { olPortCrntPMEntry 31 }
olPortCrntPMOPTAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical
power transmitted value."
::= { olPortCrntPMEntry 32 }
olPortCrntPMOPTAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average
optical power transmitted value."
::= { olPortCrntPMEntry 33 }
olPortCrntPMOPTStdDevValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The standard deviation from the average of the optical
power transmitted on the port over the interval."
::= { olPortCrntPMEntry 34 }
olPortCrntPMOPTStdDevTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the standard deviation value
for the optical power transmitted."
::= { olPortCrntPMEntry 35 }
olPortCrntPMOPTStdDevValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided standard deviation
value for the optical power transmitted."
::= { olPortCrntPMEntry 36 }
olPortCrntPMLossRxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power loss measured on the port in the
receive direction. For a Line port, this represents
the span loss. For a DCM port, this is the DCM loss.
For a client port, this is the loss of the receive
inter-connection fiber."
::= { olPortCrntPMEntry 37 }
olPortCrntPMLossRxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the receive loss value."
::= { olPortCrntPMEntry 38 }
olPortCrntPMLossRxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided receive loss
value."
::= { olPortCrntPMEntry 39 }
olPortCrntPMLossTxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power loss measured on the port in the
transmit direction. For a Line port, this represents
the far-end span loss. For a client port, this is the
loss of the transmit inter-connection fiber."
::= { olPortCrntPMEntry 40 }
olPortCrntPMLossTxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the transmit loss value."
::= { olPortCrntPMEntry 41 }
olPortCrntPMLossTxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided transmit loss
value."
::= { olPortCrntPMEntry 42 }
olPortCrntPMInitializeAll OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize all binned PM values for a given
entry in the table."
::= { olPortCrntPMEntry 43 }
-----------------------------------------------------------------------
-- Objects used to retrieve historical performance monitoring statistics
-- for ports on equipment modules assigned to optical layer groupings.
-----------------------------------------------------------------------
olPortHistPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF OlPortHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of historical performance monitoring statistics
collected for optical layer ports."
::= { olPerformance 5 }
olPortHistPMEntry OBJECT-TYPE
SYNTAX OlPortHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the Optical Layer Port
Historical Performance Monitoring table. Each row of
this table contains a full set of PM statistics and
related data for an historical measurement interval
for a given optical layer port."
INDEX { olPortHistPMCpTypeIdx,
olPortHistPMShelfIdx,
olPortHistPMSlotIdx,
olPortHistPMTypeIdx,
olPortHistPMIdx,
olPortHistPMIntervalTypeIdx,
olPortHistPMIntervalIdx }
::= { olPortHistPMTable 1 }
OlPortHistPMEntry ::= SEQUENCE { olPortHistPMCpTypeIdx CpType,
olPortHistPMShelfIdx INTEGER,
olPortHistPMSlotIdx INTEGER,
olPortHistPMTypeIdx OlPortType,
olPortHistPMIdx INTEGER,
olPortHistPMIntervalTypeIdx PMIntervalType,
olPortHistPMIntervalIdx INTEGER,
olPortHistPMOPRValue FixedX10,
olPortHistPMOPRTimeStamp DateAndTime,
olPortHistPMOPRValidity PMValidity,
olPortHistPMOPRMinValue FixedX10,
olPortHistPMOPRMinTimeStamp DateAndTime,
olPortHistPMOPRMinValidity PMValidity,
olPortHistPMOPRMaxValue FixedX10,
olPortHistPMOPRMaxTimeStamp DateAndTime,
olPortHistPMOPRMaxValidity PMValidity,
olPortHistPMOPRAvgValue FixedX10,
olPortHistPMOPRAvgTimeStamp DateAndTime,
olPortHistPMOPRAvgValidity PMValidity,
olPortHistPMOPRStdDevValue FixedX10,
olPortHistPMOPRStdDevTimeStamp DateAndTime,
olPortHistPMOPRStdDevValidity PMValidity,
olPortHistPMOPTValue FixedX10,
olPortHistPMOPTTimeStamp DateAndTime,
olPortHistPMOPTValidity PMValidity,
olPortHistPMOPTMinValue FixedX10,
olPortHistPMOPTMinTimeStamp DateAndTime,
olPortHistPMOPTMinValidity PMValidity,
olPortHistPMOPTMaxValue FixedX10,
olPortHistPMOPTMaxTimeStamp DateAndTime,
olPortHistPMOPTMaxValidity PMValidity,
olPortHistPMOPTAvgValue FixedX10,
olPortHistPMOPTAvgTimeStamp DateAndTime,
olPortHistPMOPTAvgValidity PMValidity,
olPortHistPMOPTStdDevValue FixedX10,
olPortHistPMOPTStdDevTimeStamp DateAndTime,
olPortHistPMOPTStdDevValidity PMValidity,
olPortHistPMLossRxValue FixedX10,
olPortHistPMLossRxTimeStamp DateAndTime,
olPortHistPMLossRxValidity PMValidity,
olPortHistPMLossTxValue FixedX10,
olPortHistPMLossTxTimeStamp DateAndTime,
olPortHistPMLossTxValidity PMValidity,
olPortHistPMInitializeAll InitializeCmd }
olPortHistPMCpTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of circuit pack on which the port
targeted for PMs is located."
::= { olPortHistPMEntry 1 }
olPortHistPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf in which the port
targeted for PMs is located."
::= { olPortHistPMEntry 2 }
olPortHistPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot in which the port
targeted for PMs is located."
::= { olPortHistPMEntry 3 }
olPortHistPMTypeIdx OBJECT-TYPE
SYNTAX OlPortType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of port targeted for PMs."
::= { olPortHistPMEntry 4 }
olPortHistPMIdx OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the specified
port type targeted for PMs."
::= { olPortHistPMEntry 5 }
olPortHistPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { olPortHistPMEntry 6 }
olPortHistPMIntervalIdx OBJECT-TYPE
SYNTAX INTEGER (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific PM bin number. The range is 1 to 96 for the
15-minute historical bins. For the 1-day historical bin, the
value is 1."
::= { olPortHistPMEntry 7 }
olPortHistPMOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The instantaneous optical power received on the port."
::= { olPortHistPMEntry 8 }
olPortHistPMOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the instantaneous optical
power received value."
::= { olPortHistPMEntry 9 }
olPortHistPMOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided instantaneous
optical power received value."
::= { olPortHistPMEntry 10 }
olPortHistPMOPRMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power received on the port over
the interval."
::= { olPortHistPMEntry 11 }
olPortHistPMOPRMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical
power received value."
::= { olPortHistPMEntry 12 }
olPortHistPMOPRMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum
optical power received value."
::= { olPortHistPMEntry 13 }
olPortHistPMOPRMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power received on the port over
the interval."
::= { olPortHistPMEntry 14 }
olPortHistPMOPRMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical
power received value."
::= { olPortHistPMEntry 15 }
olPortHistPMOPRMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum
optical power received value."
::= { olPortHistPMEntry 16 }
olPortHistPMOPRAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power received on the port over
the interval."
::= { olPortHistPMEntry 17 }
olPortHistPMOPRAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical
power received value."
::= { olPortHistPMEntry 18 }
olPortHistPMOPRAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average
optical power received value."
::= { olPortHistPMEntry 19 }
olPortHistPMOPRStdDevValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The standard deviation from the average of the optical
power received on the port over the interval."
::= { olPortHistPMEntry 20 }
olPortHistPMOPRStdDevTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the standard deviation value
for the optical power received."
::= { olPortHistPMEntry 21 }
olPortHistPMOPRStdDevValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided standard deviation
value for the optical power received."
::= { olPortHistPMEntry 22 }
olPortHistPMOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The instantaneous optical power transmitted on the port."
::= { olPortHistPMEntry 23 }
olPortHistPMOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the instantaneous optical
power transmitted value."
::= { olPortHistPMEntry 24 }
olPortHistPMOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided instantaneous
optical power transmitted value."
::= { olPortHistPMEntry 25 }
olPortHistPMOPTMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power transmitted on the port over
the interval."
::= { olPortHistPMEntry 26 }
olPortHistPMOPTMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical
power transmitted value."
::= { olPortHistPMEntry 27 }
olPortHistPMOPTMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum
optical power transmitted value."
::= { olPortHistPMEntry 28 }
olPortHistPMOPTMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power transmitted on the port over
the interval."
::= { olPortHistPMEntry 29 }
olPortHistPMOPTMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical
power transmitted value."
::= { olPortHistPMEntry 30 }
olPortHistPMOPTMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum
optical power transmitted value."
::= { olPortHistPMEntry 31 }
olPortHistPMOPTAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power transmitted on the port over
the interval."
::= { olPortHistPMEntry 32 }
olPortHistPMOPTAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical
power transmitted value."
::= { olPortHistPMEntry 33 }
olPortHistPMOPTAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average
optical power transmitted value."
::= { olPortHistPMEntry 34 }
olPortHistPMOPTStdDevValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The standard deviation from the average of the optical
power transmitted on the port over the interval."
::= { olPortHistPMEntry 35 }
olPortHistPMOPTStdDevTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the standard deviation value
for the optical power transmitted."
::= { olPortHistPMEntry 36 }
olPortHistPMOPTStdDevValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided standard deviation
value for the optical power transmitted."
::= { olPortHistPMEntry 37 }
olPortHistPMLossRxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power loss measured on the port in the
receive direction. For a Line port, this represents
the span loss. For a DCM port, this is the DCM loss.
For a client port, this is the loss of the receive
inter-connection fiber."
::= { olPortHistPMEntry 38 }
olPortHistPMLossRxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the receive loss value."
::= { olPortHistPMEntry 39 }
olPortHistPMLossRxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided receive loss
value."
::= { olPortHistPMEntry 40 }
olPortHistPMLossTxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power loss measured on the port in the
transmit direction. For a Line port, this represents
the far-end span loss. For a client port, this is the
loss of the transmit inter-connection fiber."
::= { olPortHistPMEntry 41 }
olPortHistPMLossTxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the transmit loss value."
::= { olPortHistPMEntry 42 }
olPortHistPMLossTxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided transmit loss
value."
::= { olPortHistPMEntry 43 }
olPortHistPMInitializeAll OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize all binned PM values for a given
entry in the table."
::= { olPortHistPMEntry 44 }
-----------------------------------------------------------------------
-- Objects used to retrieve current performance monitoring statistics
-- for wavelength channels on equipment modules assigned to optical
-- layer groupings.
-----------------------------------------------------------------------
wchCrntPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF WchCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of current performance monitoring statistics
collected for wavelength channels."
::= { olPerformance 6 }
wchCrntPMEntry OBJECT-TYPE
SYNTAX WchCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the Wavelength Channel Current
Performance Monitoring table. Each row of this table
contains a full set of PM statistics and related data
for a current measurement interval for a wavelength
channel object in an optical layer grouping."
INDEX { wchCrntPMCpTypeIdx,
wchCrntPMShelfIdx,
wchCrntPMSlotIdx,
wchCrntPMPortTypeIdx,
wchCrntPMPortIdx,
wchCrntPMIdx,
wchCrntPMIntervalTypeIdx }
::= { wchCrntPMTable 1 }
WchCrntPMEntry ::= SEQUENCE { wchCrntPMCpTypeIdx CpType,
wchCrntPMShelfIdx INTEGER,
wchCrntPMSlotIdx INTEGER,
wchCrntPMPortTypeIdx OlPortType,
wchCrntPMPortIdx INTEGER,
wchCrntPMIdx INTEGER,
wchCrntPMIntervalTypeIdx PMIntervalType,
wchCrntPMOPRValue FixedX10,
wchCrntPMOPRTimeStamp DateAndTime,
wchCrntPMOPRValidity PMValidity,
wchCrntPMOPRMinValue FixedX10,
wchCrntPMOPRMinTimeStamp DateAndTime,
wchCrntPMOPRMinValidity PMValidity,
wchCrntPMOPRMinInitialize InitializeCmd,
wchCrntPMOPRMaxValue FixedX10,
wchCrntPMOPRMaxTimeStamp DateAndTime,
wchCrntPMOPRMaxValidity PMValidity,
wchCrntPMOPRMaxInitialize InitializeCmd,
wchCrntPMOPTValue FixedX10,
wchCrntPMOPTTimeStamp DateAndTime,
wchCrntPMOPTValidity PMValidity,
wchCrntPMOPTMinValue FixedX10,
wchCrntPMOPTMinTimeStamp DateAndTime,
wchCrntPMOPTMinValidity PMValidity,
wchCrntPMOPTMinInitialize InitializeCmd,
wchCrntPMOPTMaxValue FixedX10,
wchCrntPMOPTMaxTimeStamp DateAndTime,
wchCrntPMOPTMaxValidity PMValidity,
wchCrntPMOPTMaxInitialize InitializeCmd }
wchCrntPMCpTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of circuit pack on which the wavelength channel
targeted for PMs is located."
::= { wchCrntPMEntry 1 }
wchCrntPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf in which the wavelength channel
targeted for PMs is located."
::= { wchCrntPMEntry 2 }
wchCrntPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot in which the wavelength channel
targeted for PMs is located."
::= { wchCrntPMEntry 3 }
wchCrntPMPortTypeIdx OBJECT-TYPE
SYNTAX OlPortType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of port in which the wavelength channel targeted
for PMs is located."
::= { wchCrntPMEntry 4 }
wchCrntPMPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the specified port type in
which the wavelength channel targeted for PMs is located."
::= { wchCrntPMEntry 5 }
wchCrntPMIdx OBJECT-TYPE
SYNTAX INTEGER (135..610)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the wavelength channel targeted for PMs."
::= { wchCrntPMEntry 6 }
wchCrntPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { wchCrntPMEntry 7 }
wchCrntPMOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The instantaneous optical power received on the
channel."
::= { wchCrntPMEntry 8 }
wchCrntPMOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the instantaneous optical
power received value."
::= { wchCrntPMEntry 9 }
wchCrntPMOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided instantaneous
optical power received value."
::= { wchCrntPMEntry 10 }
wchCrntPMOPRMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The minimum optical power received on the channel
over the interval. Can be set to the value 0 to initialize."
::= { wchCrntPMEntry 11 }
wchCrntPMOPRMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical
power received value."
::= { wchCrntPMEntry 12 }
wchCrntPMOPRMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum
optical power received value."
::= { wchCrntPMEntry 13 }
wchCrntPMOPRMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the wchCrntPMOPRMinValue
object."
::= { wchCrntPMEntry 14 }
wchCrntPMOPRMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The maximum optical power received on the
channel over the interval. Can be set to the
value 0 to initialize."
::= { wchCrntPMEntry 15 }
wchCrntPMOPRMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical
power received value."
::= { wchCrntPMEntry 16 }
wchCrntPMOPRMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum
optical power received value."
::= { wchCrntPMEntry 17 }
wchCrntPMOPRMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the wchCrntPMOPRMaxValue
object."
::= { wchCrntPMEntry 18 }
wchCrntPMOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The instantaneous optical power transmitted on the
channel."
::= { wchCrntPMEntry 19 }
wchCrntPMOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the instantaneous optical
power transmitted value."
::= { wchCrntPMEntry 20 }
wchCrntPMOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided instantaneous
optical power transmitted value."
::= { wchCrntPMEntry 21 }
wchCrntPMOPTMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The minimum optical power transmitted on the channel
over the interval. Can be set to the value 0 to initialize."
::= { wchCrntPMEntry 22 }
wchCrntPMOPTMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical
power transmitted value."
::= { wchCrntPMEntry 23 }
wchCrntPMOPTMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum
optical power transmitted value."
::= { wchCrntPMEntry 24 }
wchCrntPMOPTMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the wchCrntPMOPTMinValue
object."
::= { wchCrntPMEntry 25 }
wchCrntPMOPTMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The maximum optical power transmitted on the channel
over the interval. Can be set to the value 0 to initialize."
::= { wchCrntPMEntry 26 }
wchCrntPMOPTMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical
power transmitted value."
::= { wchCrntPMEntry 27 }
wchCrntPMOPTMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum
optical power transmitted value."
::= { wchCrntPMEntry 28 }
wchCrntPMOPTMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the wchCrntPMOPTMaxValue
object."
::= { wchCrntPMEntry 29 }
-----------------------------------------------------------------------
-- Objects used to retrieve historical performance monitoring
-- statistics for wavelength channels on equipment modules assigned
-- to optical layer groupings.
-----------------------------------------------------------------------
wchHistPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF WchHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of historical performance monitoring statistics
collected for wavelength channels."
::= { olPerformance 7 }
wchHistPMEntry OBJECT-TYPE
SYNTAX WchHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the Wavelength Channel
Historical Performance Monitoring table. Each row of
this table contains a full set of PM statistics and
related data for a wavelength channel object in an
optical layer grouping."
INDEX { wchHistPMCpTypeIdx,
wchHistPMShelfIdx,
wchHistPMSlotIdx,
wchHistPMPortTypeIdx,
wchHistPMPortIdx,
wchHistPMIdx,
wchHistPMIntervalTypeIdx,
wchHistPMIntervalIdx }
::= { wchHistPMTable 1 }
WchHistPMEntry ::= SEQUENCE { wchHistPMCpTypeIdx CpType,
wchHistPMShelfIdx INTEGER,
wchHistPMSlotIdx INTEGER,
wchHistPMPortTypeIdx OlPortType,
wchHistPMPortIdx INTEGER,
wchHistPMIdx INTEGER,
wchHistPMIntervalTypeIdx PMIntervalType,
wchHistPMIntervalIdx INTEGER,
wchHistPMOPRValue FixedX10,
wchHistPMOPRTimeStamp DateAndTime,
wchHistPMOPRValidity PMValidity,
wchHistPMOPRMinValue FixedX10,
wchHistPMOPRMinTimeStamp DateAndTime,
wchHistPMOPRMinValidity PMValidity,
wchHistPMOPRMinInitialize InitializeCmd,
wchHistPMOPRMaxValue FixedX10,
wchHistPMOPRMaxTimeStamp DateAndTime,
wchHistPMOPRMaxValidity PMValidity,
wchHistPMOPRMaxInitialize InitializeCmd,
wchHistPMOPTValue FixedX10,
wchHistPMOPTTimeStamp DateAndTime,
wchHistPMOPTValidity PMValidity,
wchHistPMOPTMinValue FixedX10,
wchHistPMOPTMinTimeStamp DateAndTime,
wchHistPMOPTMinValidity PMValidity,
wchHistPMOPTMinInitialize InitializeCmd,
wchHistPMOPTMaxValue FixedX10,
wchHistPMOPTMaxTimeStamp DateAndTime,
wchHistPMOPTMaxValidity PMValidity,
wchHistPMOPTMaxInitialize InitializeCmd }
wchHistPMCpTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of circuit pack on which the wavelength channel
targeted for PMs is located."
::= { wchHistPMEntry 1 }
wchHistPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf in which the wavelength channel
targeted for PMs is located."
::= { wchHistPMEntry 2 }
wchHistPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot in which the wavelength channel
targeted for PMs is located."
::= { wchHistPMEntry 3 }
wchHistPMPortTypeIdx OBJECT-TYPE
SYNTAX OlPortType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of port in which the wavelength channel targeted
for PMs is located."
::= { wchHistPMEntry 4 }
wchHistPMPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the specified port type in
which the wavelength channel targeted for PMs is located."
::= { wchHistPMEntry 5 }
wchHistPMIdx OBJECT-TYPE
SYNTAX INTEGER (135..610)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the wavelength channel targeted for PMs."
::= { wchHistPMEntry 6 }
wchHistPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { wchHistPMEntry 7 }
wchHistPMIntervalIdx OBJECT-TYPE
SYNTAX INTEGER (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific PM bin number. The range is 1 to 96 for the
15-minute historical bins. For the 1-day historical bin, the
value is 1."
::= { wchHistPMEntry 8 }
wchHistPMOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The instantaneous optical power received on the
channel."
::= { wchHistPMEntry 9 }
wchHistPMOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the instantaneous optical
power received value."
::= { wchHistPMEntry 10 }
wchHistPMOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided instantaneous
optical power received value."
::= { wchHistPMEntry 11 }
wchHistPMOPRMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The minimum optical power received on the channel
over the interval. Can be set to the value 0 to initialize
the object."
::= { wchHistPMEntry 12 }
wchHistPMOPRMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical
power received value."
::= { wchHistPMEntry 13 }
wchHistPMOPRMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum
optical power received value."
::= { wchHistPMEntry 14 }
wchHistPMOPRMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the wchHistPMOPRMinValue
object."
::= { wchHistPMEntry 15 }
wchHistPMOPRMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The maximum optical power received on the
channel over the interval. Can be set to the
value 0 to initialize the object."
::= { wchHistPMEntry 16 }
wchHistPMOPRMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical
power received value."
::= { wchHistPMEntry 17 }
wchHistPMOPRMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum
optical power received value."
::= { wchHistPMEntry 18 }
wchHistPMOPRMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the wchHistPMOPRMaxValue
object."
::= { wchHistPMEntry 19 }
wchHistPMOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The instantaneous optical power transmitted on the
channel."
::= { wchHistPMEntry 20 }
wchHistPMOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the instantaneous optical
power transmitted value."
::= { wchHistPMEntry 21 }
wchHistPMOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided instantaneous
optical power transmitted value."
::= { wchHistPMEntry 22 }
wchHistPMOPTMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The minimum optical power transmitted on the channel
over the interval. Can be set to the value 0 to initialize
the object."
::= { wchHistPMEntry 23 }
wchHistPMOPTMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical
power transmitted value."
::= { wchHistPMEntry 24 }
wchHistPMOPTMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum
optical power transmitted value."
::= { wchHistPMEntry 25 }
wchHistPMOPTMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the wchHistPMOPTMinValue
object."
::= { wchHistPMEntry 26 }
wchHistPMOPTMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The maximum optical power transmitted on the channel
over the interval. Can be set to the value 0 to initialize
the object."
::= { wchHistPMEntry 27 }
wchHistPMOPTMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical
power transmitted value."
::= { wchHistPMEntry 28 }
wchHistPMOPTMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum
optical power transmitted value."
::= { wchHistPMEntry 29 }
wchHistPMOPTMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the wchHistPMOPTMaxValue
object."
::= { wchHistPMEntry 30 }
-----------------------------------------------------------------------
-- Optical Layer Trap Definitions.
-----------------------------------------------------------------------
olOSCEvtNotifications OBJECT IDENTIFIER ::= { olEvtNotifications 1 }
olPortEvtNotifications OBJECT IDENTIFIER ::= { olEvtNotifications 2 }
wdmEvtNotifications OBJECT IDENTIFIER ::= { olEvtNotifications 3 }
wchEvtNotifications OBJECT IDENTIFIER ::= { olEvtNotifications 4 }
olOSCCondNotifications OBJECT IDENTIFIER ::= { olCondNotifications 1 }
olPortCondNotifications OBJECT IDENTIFIER ::= { olCondNotifications 2 }
wdmCondNotifications OBJECT IDENTIFIER ::= { olCondNotifications 3 }
wchCondNotifications OBJECT IDENTIFIER ::= { olCondNotifications 4 }
-----------------------------------------------------------------------
-- Optical Layer Event Traps.
-----------------------------------------------------------------------
olOSCStatusChangeEvt NOTIFICATION-TYPE
OBJECTS { olOSCCpTypeIdx,
olOSCShelfIdx,
olOSCSlotIdx,
olOSCLineIdx,
olOSCOperStatus,
olOSCOperStatQlfr,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "Notification of a change in the operational status or
operational status qualifier or an optical layer OSC
facility."
::= { olOSCEvtNotifications 0 1 }
olOSCTcaEvt NOTIFICATION-TYPE
OBJECTS { olOSCCpTypeIdx,
olOSCShelfIdx,
olOSCSlotIdx,
olOSCLineIdx,
tcaIntervalType,
tcaDateAndTime,
tcaMontype,
tcaValue,
tcaThreshold,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "This trap provides a threshold crossing alert for a
performance monitoring statistic on an optical layer
OSC facility."
::= { olOSCEvtNotifications 0 2 }
olPortStatusChangeEvt NOTIFICATION-TYPE
OBJECTS { olPortCpTypeIdx,
olPortShelfIdx,
olPortSlotIdx,
olPortTypeIdx,
olPortIdx,
olPortOperStatus,
olPortOperStatQlfr,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "Notification of a change in the operational status or
operational status qualifier or an optical layer port."
::= { olPortEvtNotifications 0 1 }
wdmStatusChangeEvt NOTIFICATION-TYPE
OBJECTS { wdmCpTypeIdx,
wdmShelfIdx,
wdmSlotIdx,
wdmLineIdx,
olPortIdx,
wdmOperStatus,
wdmOperStatQlfr,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "Notification of a change in the operational status or
operational status qualifier or an optical layer WDM
object."
::= { wdmEvtNotifications 0 1 }
wchStatusChangeEvt NOTIFICATION-TYPE
OBJECTS { wchCpTypeIdx,
wchShelfIdx,
wchSlotIdx,
wchPortTypeIdx,
wchPortIdx,
wchIdx,
wchOperStatus,
wchOperStatQlfr,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "Notification of a change in the operational status or
operational status qualifier or an optical layer WDM
object."
::= { wchEvtNotifications 0 1 }
-----------------------------------------------------------------------
-- Optical Layer Condition Traps.
-----------------------------------------------------------------------
olOSCLossOfLightRxCond NOTIFICATION-TYPE
OBJECTS { olOSCCpTypeIdx,
olOSCShelfIdx,
olOSCSlotIdx,
olOSCLineIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is no input signal detected for the identified OSC."
::= { olOSCCondNotifications 0 1 }
olOSCLossOfLightRxClear NOTIFICATION-TYPE
OBJECTS { olOSCCpTypeIdx,
olOSCShelfIdx,
olOSCSlotIdx,
olOSCLineIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical layer OSC Receive Loss of Light
condition has cleared."
::= { olOSCCondNotifications 0 2 }
olOSCLossOfFrameCond NOTIFICATION-TYPE
OBJECTS { olOSCCpTypeIdx,
olOSCShelfIdx,
olOSCSlotIdx,
olOSCLineIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There input OSC signal cannot be framed."
::= { olOSCCondNotifications 0 3 }
olOSCLossOfFrameClear NOTIFICATION-TYPE
OBJECTS { olOSCCpTypeIdx,
olOSCShelfIdx,
olOSCSlotIdx,
olOSCLineIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical layer OSC Loss of Frame
condition has cleared."
::= { olOSCCondNotifications 0 4 }
olOSCLossOfLightTxCond NOTIFICATION-TYPE
OBJECTS { olOSCCpTypeIdx,
olOSCShelfIdx,
olOSCSlotIdx,
olOSCLineIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is no transmitted signal power detected for the
identified OSC."
::= { olOSCCondNotifications 0 5 }
olOSCLossOfLightTxClear NOTIFICATION-TYPE
OBJECTS { olOSCCpTypeIdx,
olOSCShelfIdx,
olOSCSlotIdx,
olOSCLineIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical layer OSC Transmit Loss of
Light condition has cleared."
::= { olOSCCondNotifications 0 6 }
olOSCFarEndIdMismatchCond NOTIFICATION-TYPE
OBJECTS { olOSCCpTypeIdx,
olOSCShelfIdx,
olOSCSlotIdx,
olOSCLineIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The identifying attributes received for the far-end node
do not match the expected identifying attributes."
::= { olOSCCondNotifications 0 7 }
olOSCFarEndIdMismatchClear NOTIFICATION-TYPE
OBJECTS { olOSCCpTypeIdx,
olOSCShelfIdx,
olOSCSlotIdx,
olOSCLineIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical layer OSC Far End Identification
Mismatch condition has cleared."
::= { olOSCCondNotifications 0 8 }
olOSCFarEndNodeCnfgInconsistentCond NOTIFICATION-TYPE
OBJECTS { olOSCCpTypeIdx,
olOSCShelfIdx,
olOSCSlotIdx,
olOSCLineIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The optical layer group configuration type for the far-end
node is inconsistent with the configuration type of
the local optical layer group."
::= { olOSCCondNotifications 0 9 }
olOSCFarEndNodeCnfgInconsistentClear NOTIFICATION-TYPE
OBJECTS { olOSCCpTypeIdx,
olOSCShelfIdx,
olOSCSlotIdx,
olOSCLineIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical layer OSC Far End Node
Configuration Inconsistent condition has cleared."
::= { olOSCCondNotifications 0 10 }
olOSCSpanContCommCond NOTIFICATION-TYPE
OBJECTS { olOSCCpTypeIdx,
olOSCShelfIdx,
olOSCSlotIdx,
olOSCLineIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Bi-directional control communications with the node at the
opposite end of the span section have failed."
::= { olOSCCondNotifications 0 11 }
olOSCSpanContCommClear NOTIFICATION-TYPE
OBJECTS { olOSCCpTypeIdx,
olOSCShelfIdx,
olOSCSlotIdx,
olOSCLineIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical layer OSC Section Control
Communications condition has cleared."
::= { olOSCCondNotifications 0 12 }
olOSCEqlzContCommCond NOTIFICATION-TYPE
OBJECTS { olOSCCpTypeIdx,
olOSCShelfIdx,
olOSCSlotIdx,
olOSCLineIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Bi-directional control communications with the node at the
opposite end of the equalization section have failed."
::= { olOSCCondNotifications 0 13 }
olOSCEqlzContCommClear NOTIFICATION-TYPE
OBJECTS { olOSCCpTypeIdx,
olOSCShelfIdx,
olOSCSlotIdx,
olOSCLineIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical layer OSC Equalization Control
Communications condition has cleared."
::= { olOSCCondNotifications 0 14 }
olOSCOpticalBackReflOutOfSpecCond NOTIFICATION-TYPE
OBJECTS { olOSCCpTypeIdx,
olOSCShelfIdx,
olOSCSlotIdx,
olOSCLineIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The measured optical back reflection of the transmitted
OSC signal exceeds the specified maximum."
::= { olOSCCondNotifications 0 15 }
olOSCOpticalBackReflOutOfSpecClear NOTIFICATION-TYPE
OBJECTS { olOSCCpTypeIdx,
olOSCShelfIdx,
olOSCSlotIdx,
olOSCLineIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical layer OSC Optical Back
Reflection Out of Specification condition has cleared."
::= { olOSCCondNotifications 0 16 }
olOSCOpticalBackReflHighThCond NOTIFICATION-TYPE
OBJECTS { olOSCCpTypeIdx,
olOSCShelfIdx,
olOSCSlotIdx,
olOSCLineIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The measured optical back reflection of the transmitted
OSC signal exceeds the high threshold."
::= { olOSCCondNotifications 0 17 }
olOSCOpticalBackReflHighThClear NOTIFICATION-TYPE
OBJECTS { olOSCCpTypeIdx,
olOSCShelfIdx,
olOSCSlotIdx,
olOSCLineIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical layer OSC Optical Back
Reflection High Threshold condition has cleared."
::= { olOSCCondNotifications 0 18 }
olPortPowerOutOfSpecRxCond NOTIFICATION-TYPE
OBJECTS { olPortCpTypeIdx,
olPortShelfIdx,
olPortSlotIdx,
olPortTypeIdx,
olPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The power received on the optical port is outside the
operating range."
::= { olPortCondNotifications 0 1 }
olPortPowerOutOfSpecRxClear NOTIFICATION-TYPE
OBJECTS { olPortCpTypeIdx,
olPortShelfIdx,
olPortSlotIdx,
olPortTypeIdx,
olPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical layer port Received Power
Out Of Specification condition has cleared."
::= { olPortCondNotifications 0 2 }
olPortLossOfLightRxCond NOTIFICATION-TYPE
OBJECTS { olPortCpTypeIdx,
olPortShelfIdx,
olPortSlotIdx,
olPortTypeIdx,
olPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is no received optical power detected for the port."
::= { olPortCondNotifications 0 3 }
olPortLossOfLightRxClear NOTIFICATION-TYPE
OBJECTS { olPortCpTypeIdx,
olPortShelfIdx,
olPortSlotIdx,
olPortTypeIdx,
olPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical layer port Receive Loss of Light
condition has cleared."
::= { olPortCondNotifications 0 4 }
olPortLossRxOutOfSpecCond NOTIFICATION-TYPE
OBJECTS { olPortCpTypeIdx,
olPortShelfIdx,
olPortSlotIdx,
olPortTypeIdx,
olPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The optical power loss measured over the span or
fiber connection terminating on the port in the
receive direction is outside the specification range."
::= { olPortCondNotifications 0 5 }
olPortLossRxOutOfSpecClear NOTIFICATION-TYPE
OBJECTS { olPortCpTypeIdx,
olPortShelfIdx,
olPortSlotIdx,
olPortTypeIdx,
olPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical layer port Receive Loss out of
Specification condition has cleared."
::= { olPortCondNotifications 0 6 }
olPortLossRxHighThCond NOTIFICATION-TYPE
OBJECTS { olPortCpTypeIdx,
olPortShelfIdx,
olPortSlotIdx,
olPortTypeIdx,
olPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The optical power loss measured over the span terminating
on the line port in the receive direction is above
the high threshold level."
::= { olPortCondNotifications 0 7 }
olPortLossRxHighThClear NOTIFICATION-TYPE
OBJECTS { olPortCpTypeIdx,
olPortShelfIdx,
olPortSlotIdx,
olPortTypeIdx,
olPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical layer port Receive Loss
High Threshold condition has cleared."
::= { olPortCondNotifications 0 8 }
olPortAPSDCond NOTIFICATION-TYPE
OBJECTS { olPortCpTypeIdx,
olPortShelfIdx,
olPortSlotIdx,
olPortTypeIdx,
olPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "An automatic power shutdown has been automatically operated
on the optical layer port for safety reasons."
::= { olPortCondNotifications 0 9 }
olPortAPSDClear NOTIFICATION-TYPE
OBJECTS { olPortCpTypeIdx,
olPortShelfIdx,
olPortSlotIdx,
olPortTypeIdx,
olPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical layer port Automatic Power Shutdown
condition has cleared."
::= { olPortCondNotifications 0 10 }
olPortPayloadMissingIndCond NOTIFICATION-TYPE
OBJECTS { olPortCpTypeIdx,
olPortShelfIdx,
olPortSlotIdx,
olPortTypeIdx,
olPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A Payload Missing Indication has been received on the
optical layer port input."
::= { olPortCondNotifications 0 11 }
olPortPayloadMissingIndClear NOTIFICATION-TYPE
OBJECTS { olPortCpTypeIdx,
olPortShelfIdx,
olPortSlotIdx,
olPortTypeIdx,
olPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical layer port Payload Missing
Indication condition has cleared."
::= { olPortCondNotifications 0 12 }
olPortBackwardDefectIndCond NOTIFICATION-TYPE
OBJECTS { olPortCpTypeIdx,
olPortShelfIdx,
olPortSlotIdx,
olPortTypeIdx,
olPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A Backward Defect Indication has been received on the
optical layer port input."
::= { olPortCondNotifications 0 13 }
olPortBackwardDefectIndClear NOTIFICATION-TYPE
OBJECTS { olPortCpTypeIdx,
olPortShelfIdx,
olPortSlotIdx,
olPortTypeIdx,
olPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical layer port Backward Defect
Indication condition has cleared."
::= { olPortCondNotifications 0 14 }
olPortChannelCountDeficiencyCond NOTIFICATION-TYPE
OBJECTS { olPortCpTypeIdx,
olPortShelfIdx,
olPortSlotIdx,
olPortTypeIdx,
olPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A channel count deficiency condition has been raised against
the port. This indicates that the number of channels
received on the port is less than the number required to
maintain stable optical control given the high span loss
level detected on the receive span fiber."
::= { olPortCondNotifications 0 15 }
olPortChannelCountDeficiencyClear NOTIFICATION-TYPE
OBJECTS { olPortCpTypeIdx,
olPortShelfIdx,
olPortSlotIdx,
olPortTypeIdx,
olPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical layer port Channel Count
Deficiency condition has cleared."
::= { olPortCondNotifications 0 16 }
olPortConnectionMismatchCond NOTIFICATION-TYPE
OBJECTS { olPortCpTypeIdx,
olPortShelfIdx,
olPortSlotIdx,
olPortTypeIdx,
olPortIdx,
olPortExpCnxDegree,
olPortActCnxDegree,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The identified optical layer port is incorrectly
connected and must be re-connected to a different
remote end port."
::= { olPortCondNotifications 0 17 }
olPortConnectionMismatchClear NOTIFICATION-TYPE
OBJECTS { olPortCpTypeIdx,
olPortShelfIdx,
olPortSlotIdx,
olPortTypeIdx,
olPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical layer port Connection
Mismatch condition has cleared."
::= { olPortCondNotifications 0 18 }
olPortConnectionValidationTimeoutCond NOTIFICATION-TYPE
OBJECTS { olPortCpTypeIdx,
olPortShelfIdx,
olPortSlotIdx,
olPortTypeIdx,
olPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Connection validation could not be performed on the
identified optical layer port, which may mean that the
port is incorrectly connected."
::= { olPortCondNotifications 0 19 }
olPortConnectionValidationTimeoutClear NOTIFICATION-TYPE
OBJECTS { olPortCpTypeIdx,
olPortShelfIdx,
olPortSlotIdx,
olPortTypeIdx,
olPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical layer port Connection
Validation Timeout condition has cleared."
::= { olPortCondNotifications 0 20 }
wdmInvalidPreAmpOperCnfgCond NOTIFICATION-TYPE
OBJECTS { wdmCpTypeIdx,
wdmShelfIdx,
wdmSlotIdx,
wdmLineIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The WDM optical pre-amplifier is operating at a configuration
which is invalid for the detected loss."
::= { wdmCondNotifications 0 1 }
wdmInvalidPreAmpOperCnfgClear NOTIFICATION-TYPE
OBJECTS { wdmCpTypeIdx,
wdmShelfIdx,
wdmSlotIdx,
wdmLineIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active WDM Invalid Pre-Amplifier Operating
Configuration condition has cleared."
::= { wdmCondNotifications 0 2 }
wdmInvalidMidAmpOperCnfgCond NOTIFICATION-TYPE
OBJECTS { wdmCpTypeIdx,
wdmShelfIdx,
wdmSlotIdx,
wdmLineIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The WDM optical mid-amplifier is operating at a configuration
which is invalid for the detected loss."
::= { wdmCondNotifications 0 3 }
wdmInvalidMidAmpOperCnfgClear NOTIFICATION-TYPE
OBJECTS { wdmCpTypeIdx,
wdmShelfIdx,
wdmSlotIdx,
wdmLineIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active WDM Invalid Mid-Amplifier Operating
Configuration condition has cleared."
::= { wdmCondNotifications 0 4 }
wdmInvalidBoostAmpOperCnfgCond NOTIFICATION-TYPE
OBJECTS { wdmCpTypeIdx,
wdmShelfIdx,
wdmSlotIdx,
wdmLineIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The WDM optical booster-amplifier is operating at a configuration
which is invalid for the detected loss."
::= { wdmCondNotifications 0 5 }
wdmInvalidBoostAmpOperCnfgClear NOTIFICATION-TYPE
OBJECTS { wdmCpTypeIdx,
wdmShelfIdx,
wdmSlotIdx,
wdmLineIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active WDM Invalid Booster-Amplifier Operating
Configuration condition has cleared."
::= { wdmCondNotifications 0 6 }
wchPowerOutOfSpecRxCond NOTIFICATION-TYPE
OBJECTS { wchCpTypeIdx,
wchShelfIdx,
wchSlotIdx,
wchPortTypeIdx,
wchPortIdx,
wchIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS deprecated
DESCRIPTION "The power received for the wavelength channel is outside the
operating range."
::= { wchCondNotifications 0 1 }
wchPowerOutOfSpecRxClear NOTIFICATION-TYPE
OBJECTS { wchCpTypeIdx,
wchShelfIdx,
wchSlotIdx,
wchPortTypeIdx,
wchPortIdx,
wchIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS deprecated
DESCRIPTION "A previously active Wavelength Channel Received Power Out Of
Specification condition has cleared."
::= { wchCondNotifications 0 2 }
wchLossOfLightRxCond NOTIFICATION-TYPE
OBJECTS { wchCpTypeIdx,
wchShelfIdx,
wchSlotIdx,
wchPortTypeIdx,
wchPortIdx,
wchIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is no received optical power detected for the channel."
::= { wchCondNotifications 0 3 }
wchLossOfLightRxClear NOTIFICATION-TYPE
OBJECTS { wchCpTypeIdx,
wchShelfIdx,
wchSlotIdx,
wchPortTypeIdx,
wchPortIdx,
wchIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active wavelength channel Receive Loss of Light condition
has cleared."
::= { wchCondNotifications 0 4 }
wchPowerOutOfSpecTxCond NOTIFICATION-TYPE
OBJECTS { wchCpTypeIdx,
wchShelfIdx,
wchSlotIdx,
wchPortTypeIdx,
wchPortIdx,
wchIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The power transmitted for the wavelength channel is outside the
operating range."
::= { wchCondNotifications 0 5 }
wchPowerOutOfSpecTxClear NOTIFICATION-TYPE
OBJECTS { wchCpTypeIdx,
wchShelfIdx,
wchSlotIdx,
wchPortTypeIdx,
wchPortIdx,
wchIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Wavelength Channel Transmitted Power Out Of
Specification condition has cleared."
::= { wchCondNotifications 0 6 }
wchLossOfLightTxCond NOTIFICATION-TYPE
OBJECTS { wchCpTypeIdx,
wchShelfIdx,
wchSlotIdx,
wchPortTypeIdx,
wchPortIdx,
wchIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is no transmitted optical power detected for the channel."
::= { wchCondNotifications 0 7 }
wchLossOfLightTxClear NOTIFICATION-TYPE
OBJECTS { wchCpTypeIdx,
wchShelfIdx,
wchSlotIdx,
wchPortTypeIdx,
wchPortIdx,
wchIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active wavelength channel Transmitted Loss of Light
condition has cleared."
::= { wchCondNotifications 0 8 }
wchUnequippedCond NOTIFICATION-TYPE
OBJECTS { wchCpTypeIdx,
wchShelfIdx,
wchSlotIdx,
wchPortTypeIdx,
wchPortIdx,
wchIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "An unequipped indication for the wavelength channel has been
received from the far-end node of the line span."
::= { wchCondNotifications 0 9 }
wchUnequippedClear NOTIFICATION-TYPE
OBJECTS { wchCpTypeIdx,
wchShelfIdx,
wchSlotIdx,
wchPortTypeIdx,
wchPortIdx,
wchIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active wavelength channel unequipped indication
condition has cleared."
::= { wchCondNotifications 0 10 }
wchAISCond NOTIFICATION-TYPE
OBJECTS { wchCpTypeIdx,
wchShelfIdx,
wchSlotIdx,
wchPortTypeIdx,
wchPortIdx,
wchIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "An alarm indication signal for the wavelength channel has been
received from the far-end node of the line span."
::= { wchCondNotifications 0 11 }
wchAISClear NOTIFICATION-TYPE
OBJECTS { wchCpTypeIdx,
wchShelfIdx,
wchSlotIdx,
wchPortTypeIdx,
wchPortIdx,
wchIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active wavelength channel alarm indication signal
condition has cleared."
::= { wchCondNotifications 0 12 }
wchPowerOutOfSpecRxHighCond NOTIFICATION-TYPE
OBJECTS { wchCpTypeIdx,
wchShelfIdx,
wchSlotIdx,
wchPortTypeIdx,
wchPortIdx,
wchIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS deprecated
DESCRIPTION "The power received for the wavelength channel exceeds the
upper limit of the normal operating range."
::= { wchCondNotifications 0 13 }
wchPowerOutOfSpecRxHighClear NOTIFICATION-TYPE
OBJECTS { wchCpTypeIdx,
wchShelfIdx,
wchSlotIdx,
wchPortTypeIdx,
wchPortIdx,
wchIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS deprecated
DESCRIPTION "A previously active Wavelength Channel Received Power Out Of
Specification High condition has cleared."
::= { wchCondNotifications 0 14 }
wchPowerOutOfSpecRxLowCond NOTIFICATION-TYPE
OBJECTS { wchCpTypeIdx,
wchShelfIdx,
wchSlotIdx,
wchPortTypeIdx,
wchPortIdx,
wchIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS deprecated
DESCRIPTION "The power received for the wavelength channel is below the
lower limit of the normal operating range."
::= { wchCondNotifications 0 15 }
wchPowerOutOfSpecRxLowClear NOTIFICATION-TYPE
OBJECTS { wchCpTypeIdx,
wchShelfIdx,
wchSlotIdx,
wchPortTypeIdx,
wchPortIdx,
wchIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS deprecated
DESCRIPTION "A previously active Wavelength Channel Received Power Out Of
Specification Low condition has cleared."
::= { wchCondNotifications 0 16 }
wchPowerRxHighFailCond NOTIFICATION-TYPE
OBJECTS { wchCpTypeIdx,
wchShelfIdx,
wchSlotIdx,
wchPortTypeIdx,
wchPortIdx,
wchIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS deprecated
DESCRIPTION "The power received for the wavelength channel exceeds the
maximum allowable level. The wavelength channel is declared
to be failed at this power level."
::= { wchCondNotifications 0 17 }
wchPowerRxHighFailClear NOTIFICATION-TYPE
OBJECTS { wchCpTypeIdx,
wchShelfIdx,
wchSlotIdx,
wchPortTypeIdx,
wchPortIdx,
wchIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS deprecated
DESCRIPTION "A previously active Wavelength Channel Received Power
High Fail condition has cleared."
::= { wchCondNotifications 0 18 }
END -- End of BTI-OL-MIB Module, must a /NL character at the end this line!