-- Copyright (C) BTI Systems Inc. 2003-2010. All Rights Reserved.
|
|
--
|
|
-- The information contained herein is the property of BTI Systems Inc.
|
|
-- and is strictly confidential. Except as expressly authorized in
|
|
-- writing by BTI Systems Inc., the holder shall keep all information
|
|
-- contained herein confidential, shall disclose the information only
|
|
-- to its employees with a need to know, and shall protect the
|
|
-- information, in whole or in part, from disclosure and dissemination
|
|
-- to third parties with the same degree of care it uses to protect
|
|
-- its own confidential information, but with no less than reasonable
|
|
-- care. Except as expressly authorized in writing by BTI Systems Inc.,
|
|
-- the holder is granted no rights to use the information contained
|
|
-- herein.
|
|
------------------------------------------------------------------------
|
|
------------------------------------------------------------------------
|
|
|
|
BTI-OL-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, IpAddress,
|
|
Unsigned32
|
|
FROM SNMPv2-SMI
|
|
RowStatus, DisplayString, TEXTUAL-CONVENTION, DateAndTime
|
|
FROM SNMPv2-TC
|
|
btiModules
|
|
FROM BTI-MIB
|
|
opticalLayer, olEvtNotifications, olCondNotifications, trapSeqNum,
|
|
evtDateAndTime, evtDescription, evtObjectType, evtCodeType,
|
|
condReportType, condDateAndTime, condSeverity, condServiceAffecting,
|
|
condDescription, condObjectType, condCodeType, tcaIntervalType,
|
|
tcaDateAndTime, tcaMontype, tcaValue, tcaThreshold
|
|
FROM BTI-7000-MIB
|
|
CpType, BERType, AdminStatus, OperStatus, OperStatQlfr,
|
|
HoursAndMinutes, FiberType, FixedX10, FixedX100, PMIntervalType,
|
|
PMValidity, InitializeCmd
|
|
FROM BTI-TC-MIB;
|
|
|
|
olMib MODULE-IDENTITY
|
|
LAST-UPDATED "201208171200Z" -- Friday, August 17, 12:00:00 EST 2012
|
|
ORGANIZATION "BTI Systems Inc."
|
|
CONTACT-INFO "Technical Support
|
|
BTI Systems Inc.
|
|
50 Northside Road
|
|
Ottawa, Ontario, Canada K2H 5Z6
|
|
(613) 248-9154
|
|
support@btisystems.com"
|
|
DESCRIPTION "The external MIB definitions for the managenent of
|
|
the BTI Dynamic Optical Layer components including DLA-series
|
|
amplifiers and ROB-series ROADM modules."
|
|
REVISION "201208171200Z" -- Friday, August 17, 12:00:00 EST 2012
|
|
DESCRIPTION "MIB Updates for BTI 7000 Rel 10.1.0:
|
|
- deleted un-implemented table olDegreeTable
|
|
- added new traps for Connection Mismatch feature:
|
|
olPortCondNotification.0.17 - olPortCondNotification.0.20
|
|
- added new WCH traps for refined add-channel power monitoring:
|
|
wchCondNotifications.0.13 - wchCondNotifications.0.18"
|
|
REVISION "201202101200Z" -- Friday, February 10, 12:00:00 EST 2012
|
|
DESCRIPTION "MIB Updates for BTI 7000 Rel 9.2.0:
|
|
- added new object olPortRemoteId"
|
|
REVISION "201109261200Z" -- Monday, September 26, 12:00:00 EST 2011
|
|
DESCRIPTION "Initial version of the Optical Layer MIB."
|
|
|
|
::= { btiModules 6 }
|
|
|
|
|
|
------------------------------------------------------------------------
|
|
-- Optical Layer Textual Conventions
|
|
------------------------------------------------------------------------
|
|
|
|
OlGroupType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Identifies the configuration type of an optical layer
|
|
grouping."
|
|
SYNTAX INTEGER { none (1), -- Applies to an un-configured group
|
|
noEqlzTerm (2), -- Non-equalizing terminal
|
|
eqlzTerm (3), -- Channel equalizing terminal
|
|
noEqlzLine (4), -- Line amplifier node
|
|
eqlzLine (5), -- Channel equalizing line node
|
|
roadm (6) } -- Reconfigurable add drop node
|
|
|
|
OlPortType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Identifies the type of managed optical interface port
|
|
on an optical layer module."
|
|
SYNTAX INTEGER { line (1),
|
|
client (2),
|
|
dcm (3),
|
|
channel (4),
|
|
expansion (5) }
|
|
|
|
|
|
------------------------------------------------------------------------
|
|
-- The Optical Layer Group table is used to provision, de-provision,
|
|
-- edit and review optical layer module groupings.
|
|
------------------------------------------------------------------------
|
|
|
|
olGroupTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OlGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table lists all provisioned optical layer
|
|
module groupings on the node."
|
|
::= { opticalLayer 1 }
|
|
|
|
|
|
olGroupEntry OBJECT-TYPE
|
|
SYNTAX OlGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The conceptual row object of the optical layer
|
|
group table."
|
|
INDEX { olGroupIdx }
|
|
::= { olGroupTable 1 }
|
|
|
|
|
|
OlGroupEntry ::= SEQUENCE { olGroupIdx INTEGER,
|
|
olGroupType INTEGER,
|
|
olGroupId DisplayString,
|
|
olGroupCustom1 DisplayString,
|
|
olGroupCustom2 DisplayString,
|
|
olGroupCustom3 DisplayString,
|
|
olGroupRowStatus RowStatus }
|
|
|
|
|
|
olGroupIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A number which uniquely identifies the optical layer
|
|
group within the node."
|
|
::= { olGroupEntry 1 }
|
|
|
|
|
|
olGroupType OBJECT-TYPE
|
|
SYNTAX OlGroupType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The optical layer group configuration type. This is a
|
|
mandatory object that must be specified when a row of
|
|
the table is created. The value of none is not
|
|
applicable for this object."
|
|
::= { olGroupEntry 2 }
|
|
|
|
|
|
olGroupId OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Textual data recorded by the user to briefly identify
|
|
the provisioned optical layer group in a manner useful
|
|
to the user."
|
|
DEFVAL { "" }
|
|
::= { olGroupEntry 3 }
|
|
|
|
|
|
olGroupCustom1 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "A variable length text string for operating company use."
|
|
DEFVAL { "" }
|
|
::= { olGroupEntry 4 }
|
|
|
|
|
|
olGroupCustom2 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "A variable length text string for operating company use."
|
|
DEFVAL { "" }
|
|
::= { olGroupEntry 5 }
|
|
|
|
|
|
olGroupCustom3 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "A variable length text string for operating company use."
|
|
DEFVAL { "" }
|
|
::= { olGroupEntry 6 }
|
|
|
|
|
|
olGroupRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Used to control the addition and deletion of entries in the
|
|
optical layer group table."
|
|
::= { olGroupEntry 100 }
|
|
|
|
------------------------------------------------------------------------
|
|
-- The Optical Layer Equipment table is used to manage assignments of
|
|
-- provisioned equipment modules to optical layer groupings. Create an
|
|
-- entry in the table to assign a provisioned equipment module to an
|
|
-- optical layer group. Delete the entry to unassign the equipment.
|
|
------------------------------------------------------------------------
|
|
|
|
olEqptTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OlEqptEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table lists all provisioned equipment modules
|
|
that are assigned to an optical layer grouping."
|
|
::= { opticalLayer 3 }
|
|
|
|
|
|
olEqptEntry OBJECT-TYPE
|
|
SYNTAX OlEqptEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The conceptual row object of the optical layer
|
|
equipment table."
|
|
INDEX { olEqptCpTypeIdx, -- CP Type
|
|
olEqptShelfIdx, -- Shelf Num
|
|
olEqptSlotIdx } -- Slot Num
|
|
::= { olEqptTable 1 }
|
|
|
|
|
|
OlEqptEntry ::= SEQUENCE { olEqptCpTypeIdx CpType,
|
|
olEqptShelfIdx INTEGER,
|
|
olEqptSlotIdx INTEGER,
|
|
olEqptGroupNum INTEGER,
|
|
olEqptDegreeNum INTEGER,
|
|
olEqptRowStatus RowStatus }
|
|
|
|
|
|
olEqptCpTypeIdx OBJECT-TYPE
|
|
SYNTAX CpType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of circuit pack of the equipment module that
|
|
is assigned to the optical layer group."
|
|
::= { olEqptEntry 1 }
|
|
|
|
|
|
olEqptShelfIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (0|1|11|21|31)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the shelf of the equipment module that
|
|
is assigned to the optical layer group. For equipment
|
|
modules that do not reside in a shelf (40-channel
|
|
Mux/Demux), the value of this object is 0."
|
|
::= { olEqptEntry 2 }
|
|
|
|
|
|
olEqptSlotIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the slot of the equipment module that is
|
|
assigned to the optical layer group. For equipment
|
|
modules that do not reside in an active shelf slot
|
|
(ex. 40-channel Mux/Demux), this object represents
|
|
the module index among modules attributed to shelf 0."
|
|
::= { olEqptEntry 3 }
|
|
|
|
|
|
olEqptGroupNum OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The optical layer group to which the equipment modules
|
|
is assigned."
|
|
::= { olEqptEntry 4 }
|
|
|
|
|
|
olEqptDegreeNum OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The optical layer group degree to which the equipment
|
|
module is assigned."
|
|
::= { olEqptEntry 5 }
|
|
|
|
|
|
olEqptRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Used to control the addition and deletion of entries
|
|
in the optical layer equipment table, which in turn,
|
|
controls the assigning and unassigning of equipment
|
|
modules to/from an optical layer grouping."
|
|
::= { olEqptEntry 100 }
|
|
|
|
|
|
------------------------------------------------------------------------
|
|
-- The Optical Layer Port table is used to manage optical ports on
|
|
-- equipment modules assigned to optical layer groupings. Most entries
|
|
-- in the optical layer port table are auto-created when the supporting
|
|
-- equipment module is assigned to an optical layer group. Manual
|
|
-- provisioning and de-provisioning of client port C2 is supported on
|
|
-- ROB packs assigned to a Channel-equalizing Terminal or Reconfigurable
|
|
-- Add/Drop node group configuration.
|
|
------------------------------------------------------------------------
|
|
|
|
|
|
olPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OlPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table lists all managed ports on equipment modules
|
|
assigned to optical layer groupings."
|
|
::= { opticalLayer 4 }
|
|
|
|
|
|
olPortEntry OBJECT-TYPE
|
|
SYNTAX OlPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The conceptual row object of the optical layer port
|
|
table."
|
|
INDEX { olPortCpTypeIdx, -- CP Type
|
|
olPortShelfIdx, -- Shelf Num
|
|
olPortSlotIdx, -- Slot Num
|
|
olPortTypeIdx, -- Port Type
|
|
olPortIdx } -- Port Num
|
|
::= { olPortTable 1 }
|
|
|
|
|
|
OlPortEntry ::= SEQUENCE { olPortCpTypeIdx CpType,
|
|
olPortShelfIdx INTEGER,
|
|
olPortSlotIdx INTEGER,
|
|
olPortTypeIdx OlPortType,
|
|
olPortIdx INTEGER,
|
|
olPortId DisplayString,
|
|
olPortCustom1 DisplayString,
|
|
olPortCustom2 DisplayString,
|
|
olPortCustom3 DisplayString,
|
|
olPortDWDMType INTEGER,
|
|
olPortGrid INTEGER,
|
|
olPortWavelength FixedX100,
|
|
olPortFrequency FixedX100,
|
|
olPortOperStatus OperStatus,
|
|
olPortOperStatQlfr OperStatQlfr,
|
|
olPortRemoteId DisplayString,
|
|
olPortExpCnxDegree INTEGER,
|
|
olPortActCnxDegree INTEGER,
|
|
olPortRowStatus RowStatus }
|
|
|
|
|
|
olPortCpTypeIdx OBJECT-TYPE
|
|
SYNTAX CpType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of circuit pack on which the optical layer
|
|
port is located."
|
|
::= { olPortEntry 1 }
|
|
|
|
|
|
olPortShelfIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (0|1|11|21|31)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the shelf on which the optical layer
|
|
port is located."
|
|
::= { olPortEntry 2 }
|
|
|
|
|
|
olPortSlotIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the slot on which the optical layer
|
|
port is located."
|
|
::= { olPortEntry 3 }
|
|
|
|
|
|
olPortTypeIdx OBJECT-TYPE
|
|
SYNTAX OlPortType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of optical layer port according to the
|
|
function it provides."
|
|
::= { olPortEntry 4 }
|
|
|
|
|
|
olPortIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..600)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the optical layer port of the specified
|
|
port type."
|
|
::= { olPortEntry 5 }
|
|
|
|
|
|
olPortId OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Textual data recorded by the user to briefly identify
|
|
the provisioned optical layer port in a manner useful
|
|
to the user."
|
|
DEFVAL { "" }
|
|
::= { olPortEntry 6 }
|
|
|
|
|
|
olPortCustom1 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "A variable length text string for operating company use."
|
|
DEFVAL { "" }
|
|
::= { olPortEntry 7 }
|
|
|
|
|
|
olPortCustom2 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "A variable length text string for operating company use."
|
|
DEFVAL { "" }
|
|
::= { olPortEntry 8 }
|
|
|
|
|
|
olPortCustom3 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "A variable length text string for operating company use."
|
|
DEFVAL { "" }
|
|
::= { olPortEntry 9 }
|
|
|
|
|
|
olPortDWDMType OBJECT-TYPE
|
|
SYNTAX INTEGER { native (1),
|
|
alien (2) }
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Used to configure the port for the type of DWDM composite
|
|
to which it is inter-connection. By default, all ports are
|
|
inter-connected with native optical layer DWDM composites.
|
|
For some configurations, client port 2 of ROB2 pack and
|
|
ROB4 modules may be configured for alien DWDM type."
|
|
DEFVAL { native }
|
|
::= { olPortEntry 10 }
|
|
|
|
|
|
olPortGrid OBJECT-TYPE
|
|
SYNTAX INTEGER { ghz100 (1),
|
|
ghz50 (2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The DWDM grid spacing on the port."
|
|
DEFVAL { ghz100 }
|
|
::= { olPortEntry 11 }
|
|
|
|
|
|
olPortWavelength OBJECT-TYPE
|
|
SYNTAX FixedX100
|
|
UNITS "nanometers/100"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The wavelength of the channel carried by the port.
|
|
This object exists only in table entries for channel
|
|
ports on Mux/Demux modules."
|
|
::= { olPortEntry 12 }
|
|
|
|
|
|
olPortFrequency OBJECT-TYPE
|
|
SYNTAX FixedX100
|
|
UNITS "terahertz/100"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The frequency of the channel carried by the port.
|
|
This object exists only in table entries for channel
|
|
ports on Mux/Demux modules."
|
|
::= { olPortEntry 13 }
|
|
|
|
|
|
olPortOperStatus OBJECT-TYPE
|
|
SYNTAX OperStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The reported operational status of the optical layer port."
|
|
::= { olPortEntry 14 }
|
|
|
|
|
|
olPortOperStatQlfr OBJECT-TYPE
|
|
SYNTAX OperStatQlfr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is a textual list of qualifiers about the reported
|
|
operational status of the optical layer port."
|
|
::= { olPortEntry 15 }
|
|
|
|
|
|
olPortRemoteId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Identifies the remote node and port to which the
|
|
optical layer port is connected, in the format
|
|
prescribed by the PSM network management system."
|
|
DEFVAL { "" }
|
|
::= { olPortEntry 16 }
|
|
|
|
|
|
olPortExpCnxDegree OBJECT-TYPE
|
|
SYNTAX INTEGER (2..4)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "The expected degree number of the equipment that is
|
|
inter-connected on the port."
|
|
::= { olPortEntry 17 }
|
|
|
|
|
|
olPortActCnxDegree OBJECT-TYPE
|
|
SYNTAX INTEGER (2..4)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "The actual degree number of the equipment that is
|
|
inter-connected on the port."
|
|
::= { olPortEntry 18 }
|
|
|
|
|
|
olPortRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Used to control the addition and deletion of entries
|
|
in the Optical Layer Port table. Manual creation and
|
|
deletion is supported only for the client 2 port on
|
|
ROB packs assigned to a Channel-equalizing Terminal
|
|
or Reconfigurable Add/Drop node group."
|
|
::= { olPortEntry 100 }
|
|
|
|
|
|
|
|
------------------------------------------------------------------------
|
|
-- The equipment connection table lists all intra-group optical fiber
|
|
-- patch connections that must be in place to inter-connect equipment
|
|
-- modules assigned to optical layer groupings.
|
|
------------------------------------------------------------------------
|
|
|
|
|
|
eqptConnTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EqptConnEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table lists all intra-group optical fiber patch
|
|
connections between ports on equipment modules assigned
|
|
to optical layer groupings."
|
|
::= { opticalLayer 5 }
|
|
|
|
|
|
eqptConnEntry OBJECT-TYPE
|
|
SYNTAX EqptConnEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The conceptual row object of the equipment connection
|
|
table."
|
|
INDEX { eqptConnSrcCpTypeIdx, -- Source CP Type
|
|
eqptConnSrcShelfIdx, -- Source Shelf Num
|
|
eqptConnSrcSlotIdx, -- Source Slot Num
|
|
eqptConnSrcPortTypeIdx, -- Source Port Type
|
|
eqptConnSrcIdx, -- Source Port Num
|
|
eqptConnDstCpTypeIdx, -- Destination CP Type
|
|
eqptConnDstShelfIdx, -- Destination Shelf Num
|
|
eqptConnDstSlotIdx, -- Destination Slot Num
|
|
eqptConnDstPortTypeIdx, -- Destination Port Type
|
|
eqptConnDstIdx } -- Destination Port Num
|
|
::= { eqptConnTable 1 }
|
|
|
|
|
|
EqptConnEntry ::= SEQUENCE { eqptConnSrcCpTypeIdx CpType,
|
|
eqptConnSrcShelfIdx INTEGER,
|
|
eqptConnSrcSlotIdx INTEGER,
|
|
eqptConnSrcPortTypeIdx OlPortType,
|
|
eqptConnSrcIdx INTEGER,
|
|
eqptConnDstCpTypeIdx CpType,
|
|
eqptConnDstShelfIdx INTEGER,
|
|
eqptConnDstSlotIdx INTEGER,
|
|
eqptConnDstPortTypeIdx OlPortType,
|
|
eqptConnDstIdx INTEGER,
|
|
eqptConnType INTEGER,
|
|
eqptConnRowStatus RowStatus }
|
|
|
|
|
|
eqptConnSrcCpTypeIdx OBJECT-TYPE
|
|
SYNTAX CpType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of circuit pack on which the source port
|
|
of the equipment connection is located."
|
|
::= { eqptConnEntry 1 }
|
|
|
|
|
|
eqptConnSrcShelfIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (0|1|11|21|31)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the shelf on which the source port
|
|
of the equipment connection is located."
|
|
::= { eqptConnEntry 2 }
|
|
|
|
|
|
eqptConnSrcSlotIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the slot on which the source port
|
|
of the equipment connection is located."
|
|
::= { eqptConnEntry 3 }
|
|
|
|
|
|
eqptConnSrcPortTypeIdx OBJECT-TYPE
|
|
SYNTAX OlPortType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of the source port of the equipment connection,
|
|
according to the function it provides."
|
|
::= { eqptConnEntry 4 }
|
|
|
|
|
|
eqptConnSrcIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..600)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the port of the specified port type
|
|
of the source port of the equipment connection."
|
|
::= { eqptConnEntry 5 }
|
|
|
|
|
|
eqptConnDstCpTypeIdx OBJECT-TYPE
|
|
SYNTAX CpType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of circuit pack on which the destination port
|
|
of the equipment connection is located."
|
|
::= { eqptConnEntry 6 }
|
|
|
|
|
|
eqptConnDstShelfIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (0|1|11|21|31)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the shelf on which the destination port
|
|
of the equipment connection is located."
|
|
::= { eqptConnEntry 7 }
|
|
|
|
|
|
eqptConnDstSlotIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the slot on which the destination port
|
|
of the equipment connection is located."
|
|
::= { eqptConnEntry 8 }
|
|
|
|
|
|
eqptConnDstPortTypeIdx OBJECT-TYPE
|
|
SYNTAX OlPortType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of the destination port of the equipment
|
|
connection, according to the function it provides."
|
|
::= { eqptConnEntry 9 }
|
|
|
|
|
|
eqptConnDstIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..600)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the port of the specified port type
|
|
of the destination port of the equipment connection."
|
|
::= { eqptConnEntry 10 }
|
|
|
|
|
|
eqptConnType OBJECT-TYPE
|
|
SYNTAX INTEGER { duplex (1),
|
|
loopback (2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The type of optical fiber patch cable for the equipment
|
|
connection entry."
|
|
::= { eqptConnEntry 11 }
|
|
|
|
|
|
eqptConnRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "The equipment connection table RowStatus object is not
|
|
readable or writeable because all entries in the table
|
|
are automatically created and deleted as equipment
|
|
modules are assigned and unassigned to optical layer
|
|
groupings. This equipment connection row status object
|
|
is used only in database change notifications to
|
|
indicate if the row has been created or deleted."
|
|
::= { eqptConnEntry 100 }
|
|
|
|
|
|
|
|
------------------------------------------------------------------------
|
|
-- The Optical Layer OSC table is used to configure and monitor OSC
|
|
-- managed objects on optical layer equipment modules.
|
|
------------------------------------------------------------------------
|
|
|
|
|
|
olOSCTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OlOSCEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table lists all OSC managed objects that have
|
|
been created on the optical layer equipment modules."
|
|
::= { opticalLayer 6 }
|
|
|
|
|
|
olOSCEntry OBJECT-TYPE
|
|
SYNTAX OlOSCEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The conceptual row object of the optical laye OSC table."
|
|
INDEX { olOSCCpTypeIdx, -- CP Type
|
|
olOSCShelfIdx, -- Shelf Num
|
|
olOSCSlotIdx, -- Slot Num
|
|
olOSCLineIdx } -- Line Num
|
|
::= { olOSCTable 1 }
|
|
|
|
|
|
OlOSCEntry ::= SEQUENCE { olOSCCpTypeIdx CpType,
|
|
olOSCShelfIdx INTEGER,
|
|
olOSCSlotIdx INTEGER,
|
|
olOSCLineIdx INTEGER,
|
|
olOSCAdminStatus AdminStatus,
|
|
olOSCOperStatus OperStatus,
|
|
olOSCOperStatQlfr OperStatQlfr,
|
|
olOSCAutoEnableTimer HoursAndMinutes,
|
|
olOSCActAutoEnableTimer HoursAndMinutes,
|
|
olOSCId DisplayString,
|
|
olOSCCustom1 DisplayString,
|
|
olOSCCustom2 DisplayString,
|
|
olOSCCustom3 DisplayString,
|
|
olOSCFEIMMon INTEGER,
|
|
olOSCExpFESysName DisplayString,
|
|
olOSCExpFEIPAddr IpAddress,
|
|
olOSCExpFEGrp INTEGER,
|
|
olOSCExpFEDegr INTEGER,
|
|
olOSCFESysName DisplayString,
|
|
olOSCFEIPAddr IpAddress,
|
|
olOSCFEGrp INTEGER,
|
|
olOSCFEDegr INTEGER,
|
|
olOSCFEGrpType OlGroupType,
|
|
olOSCRowStatus RowStatus }
|
|
|
|
|
|
olOSCCpTypeIdx OBJECT-TYPE
|
|
SYNTAX CpType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of circuit pack on which the OSC is located."
|
|
::= { olOSCEntry 1 }
|
|
|
|
|
|
olOSCShelfIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1|11|21|31)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the shelf in which the OSC is located."
|
|
::= { olOSCEntry 2 }
|
|
|
|
|
|
olOSCSlotIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..20)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the slot in which the OSC is located."
|
|
::= { olOSCEntry 3 }
|
|
|
|
|
|
olOSCLineIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The line number of the OSC."
|
|
::= { olOSCEntry 4 }
|
|
|
|
|
|
olOSCAdminStatus OBJECT-TYPE
|
|
SYNTAX AdminStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The administrative status of the OSC. The default value
|
|
is autoEnabled if the supporting equipment is enabled
|
|
or autoEnabled, otherwise it is disabled."
|
|
::= { olOSCEntry 5 }
|
|
|
|
|
|
olOSCOperStatus OBJECT-TYPE
|
|
SYNTAX OperStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The reported operational status of the OSC."
|
|
::= { olOSCEntry 6 }
|
|
|
|
|
|
olOSCOperStatQlfr OBJECT-TYPE
|
|
SYNTAX OperStatQlfr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is a textual list of qualifiers about the reported
|
|
operational status of the OSC."
|
|
::= { olOSCEntry 7 }
|
|
|
|
|
|
olOSCAutoEnableTimer OBJECT-TYPE
|
|
SYNTAX HoursAndMinutes
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Specifies the auto-enable timer for the targeted OSC.
|
|
This value only applies if the olOSCAdminStatus object
|
|
is set to autoEnabled, in which case the default value is
|
|
008-00, otherwise, it is 000-00."
|
|
::= { olOSCEntry 8 }
|
|
|
|
|
|
olOSCActAutoEnableTimer OBJECT-TYPE
|
|
SYNTAX HoursAndMinutes
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the time remaining on the auto-enable timer if
|
|
it is actively counting down. Otherwise, the value returned
|
|
is 000-00."
|
|
::= { olOSCEntry 9 }
|
|
|
|
|
|
olOSCId OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Textual data recorded by the user to briefly identify the
|
|
OSC object in a manner useful to the user."
|
|
DEFVAL { "" }
|
|
::= { olOSCEntry 10 }
|
|
|
|
|
|
olOSCCustom1 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "A variable length text string for operating company use."
|
|
DEFVAL { "" }
|
|
::= { olOSCEntry 11 }
|
|
|
|
|
|
olOSCCustom2 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "A variable length text string for operating company use."
|
|
DEFVAL { "" }
|
|
::= { olOSCEntry 12 }
|
|
|
|
|
|
olOSCCustom3 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "A variable length text string for operating company use."
|
|
DEFVAL { "" }
|
|
::= { olOSCEntry 13 }
|
|
|
|
|
|
olOSCFEIMMon OBJECT-TYPE
|
|
SYNTAX INTEGER { enabled (1),
|
|
disabled (2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object is used to control the monitoring of the Far
|
|
End Node Mismatch Identifier condition. When enabled, the
|
|
received far-end node identification attributes will be
|
|
monitored and compared to the expected far-end node
|
|
identification attribites, and a condition is raised if
|
|
attributes do no match."
|
|
DEFVAL { disabled }
|
|
::= { olOSCEntry 14 }
|
|
|
|
|
|
olOSCExpFESysName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..20))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The expected far-end node system identifier."
|
|
DEFVAL { "" }
|
|
::= { olOSCEntry 15 }
|
|
|
|
|
|
olOSCExpFEIPAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The expected far-end node IP address."
|
|
DEFVAL { 0 }
|
|
::= { olOSCEntry 16 }
|
|
|
|
|
|
olOSCExpFEGrp OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The expected far-end node optical layer group number."
|
|
DEFVAL { 0 }
|
|
::= { olOSCEntry 17 }
|
|
|
|
|
|
olOSCExpFEDegr OBJECT-TYPE
|
|
SYNTAX INTEGER (0..4)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The expected far-end node optical layer degree number."
|
|
DEFVAL { 0 }
|
|
::= { olOSCEntry 18 }
|
|
|
|
|
|
olOSCFESysName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..20))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The actual far-end node system identifier."
|
|
::= { olOSCEntry 19 }
|
|
|
|
|
|
olOSCFEIPAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The actual far-end node IP address."
|
|
::= { olOSCEntry 20 }
|
|
|
|
|
|
olOSCFEGrp OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The actual far-end node optical layer group number."
|
|
::= { olOSCEntry 21 }
|
|
|
|
|
|
olOSCFEDegr OBJECT-TYPE
|
|
SYNTAX INTEGER (0..4)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The actual far-end node optical layer degree number."
|
|
::= { olOSCEntry 22 }
|
|
|
|
|
|
olOSCFEGrpType OBJECT-TYPE
|
|
SYNTAX OlGroupType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The actual far-end node optical layer group
|
|
configuration type."
|
|
::= { olOSCEntry 23 }
|
|
|
|
|
|
olOSCRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "The Optical Layer OSC table RowStatus object is not
|
|
readable or writeable because all entries in the table
|
|
are automatically created and deleted when the
|
|
supporting DLA or ROB equipment is provisioned. This
|
|
optical layer OSC row status object is used only in
|
|
database change notifications to indicate if the
|
|
row has been created or deleted."
|
|
::= { olOSCEntry 100 }
|
|
|
|
|
|
|
|
------------------------------------------------------------------------
|
|
-- The ODCC table is used to provision and administer the OSC data
|
|
-- communications channel on an optical layer OSC object which is used
|
|
-- for management communications.
|
|
------------------------------------------------------------------------
|
|
|
|
|
|
odccTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OdccEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table lists all provisioned ODCC objects on
|
|
equipment modules assigned to optical layer groupings."
|
|
::= { opticalLayer 7 }
|
|
|
|
|
|
odccEntry OBJECT-TYPE
|
|
SYNTAX OdccEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The conceptual row object of the ODCC table."
|
|
INDEX { odccCpTypeIdx, -- CP Type
|
|
odccShelfIdx, -- Shelf Num
|
|
odccSlotIdx, -- Slot Num
|
|
odccLineIdx } -- Line Num
|
|
::= { odccTable 1 }
|
|
|
|
|
|
OdccEntry ::= SEQUENCE { odccCpTypeIdx CpType,
|
|
odccShelfIdx INTEGER,
|
|
odccSlotIdx INTEGER,
|
|
odccLineIdx INTEGER,
|
|
odccAdminStatus AdminStatus,
|
|
odccRowStatus RowStatus }
|
|
|
|
|
|
odccCpTypeIdx OBJECT-TYPE
|
|
SYNTAX CpType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of circuit pack on which the ODCC is located."
|
|
::= { odccEntry 1 }
|
|
|
|
|
|
odccShelfIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1|11|21|31)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the shelf in which the ODCC is located."
|
|
::= { odccEntry 2 }
|
|
|
|
|
|
odccSlotIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..20)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the slot in which the ODC is located."
|
|
::= { odccEntry 3 }
|
|
|
|
|
|
odccLineIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The line number of the ODCC."
|
|
::= { odccEntry 4 }
|
|
|
|
|
|
odccAdminStatus OBJECT-TYPE
|
|
SYNTAX AdminStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The administrative status of the ODCC. The default value
|
|
is disabled if the supporting ODC is disabled, otherwise
|
|
it is enabled."
|
|
::= { odccEntry 5 }
|
|
|
|
|
|
odccRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Used to control the addition and deletion of entries in the
|
|
ODCC table, which in turn controls the provisioning
|
|
and de-provisioning of ODCC objects."
|
|
::= { odccEntry 100 }
|
|
|
|
|
|
|
|
------------------------------------------------------------------------
|
|
-- The WDM table is used to configure and monitor WDM managed
|
|
-- objects on equipment modules assigned to optical layer groupings.
|
|
------------------------------------------------------------------------
|
|
|
|
|
|
wdmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WdmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table lists all WDM managed objects that
|
|
have been created on optical layer equipment."
|
|
::= { opticalLayer 8 }
|
|
|
|
|
|
wdmEntry OBJECT-TYPE
|
|
SYNTAX WdmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The conceptual row object of the WDM table."
|
|
INDEX { wdmCpTypeIdx, -- CP Type
|
|
wdmShelfIdx, -- Shelf Num
|
|
wdmSlotIdx, -- Slot Num
|
|
wdmLineIdx } -- Line Num
|
|
::= { wdmTable 1 }
|
|
|
|
|
|
WdmEntry ::= SEQUENCE { wdmCpTypeIdx CpType,
|
|
wdmShelfIdx INTEGER,
|
|
wdmSlotIdx INTEGER,
|
|
wdmLineIdx INTEGER,
|
|
wdmAdminStatus AdminStatus,
|
|
wdmOperStatus OperStatus,
|
|
wdmOperStatQlfr OperStatQlfr,
|
|
wdmAutoEnableTimer HoursAndMinutes,
|
|
wdmActAutoEnableTimer HoursAndMinutes,
|
|
wdmId DisplayString,
|
|
wdmCustom1 DisplayString,
|
|
wdmCustom2 DisplayString,
|
|
wdmCustom3 DisplayString,
|
|
wdmFiberType INTEGER,
|
|
wdmSpanLength Unsigned32,
|
|
wdmSpanLossRxHighTh FixedX10,
|
|
wdmSpanLossSpecMax FixedX10,
|
|
wdmNumChannels INTEGER,
|
|
wdmRowStatus RowStatus }
|
|
|
|
|
|
wdmCpTypeIdx OBJECT-TYPE
|
|
SYNTAX CpType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of circuit pack on which the WDM is located."
|
|
::= { wdmEntry 1 }
|
|
|
|
|
|
wdmShelfIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1|11|21|31)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the shelf in which the WDM is located."
|
|
::= { wdmEntry 2 }
|
|
|
|
|
|
wdmSlotIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..20)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the slot in which the WDM is located."
|
|
::= { wdmEntry 3 }
|
|
|
|
|
|
wdmLineIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The line number of the WDM."
|
|
::= { wdmEntry 4 }
|
|
|
|
|
|
wdmAdminStatus OBJECT-TYPE
|
|
SYNTAX AdminStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The administrative status of the WDM. The default value
|
|
is autoEnabled if the supporting equipment is enabled
|
|
or autoEnabled, otherwise it is disabled."
|
|
::= { wdmEntry 5 }
|
|
|
|
|
|
wdmOperStatus OBJECT-TYPE
|
|
SYNTAX OperStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The reported operational status of the WDM."
|
|
::= { wdmEntry 6 }
|
|
|
|
|
|
wdmOperStatQlfr OBJECT-TYPE
|
|
SYNTAX OperStatQlfr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is a textual list of qualifiers about the reported
|
|
operational status of the WDM."
|
|
::= { wdmEntry 7 }
|
|
|
|
|
|
wdmAutoEnableTimer OBJECT-TYPE
|
|
SYNTAX HoursAndMinutes
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Specifies the auto-enable timer for the targeted WDM.
|
|
This value only applies if the wdmAdminStatus object
|
|
is set to autoEnabled, in which case the default value is
|
|
008-00, otherwise, it is 000-00."
|
|
::= { wdmEntry 8 }
|
|
|
|
|
|
wdmActAutoEnableTimer OBJECT-TYPE
|
|
SYNTAX HoursAndMinutes
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the time remaining on the auto-enable timer if
|
|
it is actively counting down. Otherwise, the value returned
|
|
is 000-00."
|
|
::= { wdmEntry 9 }
|
|
|
|
|
|
wdmId OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Textual data recorded by the user to briefly identify the
|
|
WDM object in a manner useful to the user."
|
|
DEFVAL { "" }
|
|
::= { wdmEntry 10 }
|
|
|
|
|
|
wdmCustom1 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "A variable length text string for operating company use."
|
|
DEFVAL { "" }
|
|
::= { wdmEntry 11 }
|
|
|
|
|
|
wdmCustom2 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "A variable length text string for operating company use."
|
|
DEFVAL { "" }
|
|
::= { wdmEntry 12 }
|
|
|
|
|
|
wdmCustom3 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "A variable length text string for operating company use."
|
|
DEFVAL { "" }
|
|
::= { wdmEntry 13 }
|
|
|
|
|
|
wdmFiberType OBJECT-TYPE
|
|
SYNTAX INTEGER { smf (1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The fiber type of the span fiber."
|
|
DEFVAL { smf }
|
|
::= { wdmEntry 14 }
|
|
|
|
|
|
wdmSpanLength OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "kilometers"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The measured length of the receive span fiber."
|
|
::= { wdmEntry 15 }
|
|
|
|
|
|
wdmSpanLossRxHighTh OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dB/10"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The high threshold setting for the loss on the receive
|
|
fiber of the Line span. The setting for this object is
|
|
used to evaluate the olPortLossRxHighThCond trap. When
|
|
the value of this object is set to 0, the
|
|
olPortLossRxHighThCond trap is disabled."
|
|
::= { wdmEntry 16 }
|
|
|
|
|
|
wdmSpanLossSpecMax OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dB/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The specified maximum supported loss on the Line span.
|
|
The value of this object is dependent on the optical
|
|
layer group configurations of the local and far-end nodes."
|
|
::= { wdmEntry 17 }
|
|
|
|
|
|
wdmNumChannels OBJECT-TYPE
|
|
SYNTAX INTEGER (0..44)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The actual number of channels that the WDM is currently
|
|
provisioned to carry."
|
|
::= { wdmEntry 18 }
|
|
|
|
|
|
wdmRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "The WDM table RowStatus object is not readable or
|
|
writeable because all entries in the table are
|
|
automatically created and deleted when the supporting
|
|
DLA or ROB circuit pack is assigned and unassigned
|
|
to an optical layer grouping. This WDM row status
|
|
object is used only in database change notifications
|
|
to indicate if the row has been created or deleted."
|
|
::= { wdmEntry 100 }
|
|
|
|
|
|
|
|
------------------------------------------------------------------------
|
|
-- The Wavelength Channel Cross Connection table is used to provision
|
|
-- and retrieve wavelength channel cross-connections. Wavelength channel
|
|
-- cross-connections are configured to route add/drop and pass-through
|
|
-- optical channels through ROB-equipped optical layer groupings.
|
|
------------------------------------------------------------------------
|
|
|
|
|
|
wchXCTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WchXCEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table lists all configured wavelength channel
|
|
cross-connections configured on optical layer equipment."
|
|
::= { opticalLayer 9 }
|
|
|
|
|
|
wchXCEntry OBJECT-TYPE
|
|
SYNTAX WchXCEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The conceptual row object of the wavelength channel
|
|
cross-connection table."
|
|
INDEX { wchXCSrcCpTypeIdx, -- Source CP Type
|
|
wchXCSrcShelfIdx, -- Source Shelf Num
|
|
wchXCSrcSlotIdx, -- Source Slot Num
|
|
wchXCSrcPortTypeIdx, -- Source Port Type
|
|
wchXCSrcPortIdx, -- Source Port Num
|
|
wchXCSrcChannelIdx, -- Source Channel Num
|
|
wchXCDstCpTypeIdx, -- Destination CP Type
|
|
wchXCDstShelfIdx, -- Destination Shelf Num
|
|
wchXCDstSlotIdx, -- Destination Slot Num
|
|
wchXCDstPortTypeIdx, -- Destination Port Type
|
|
wchXCDstPortIdx, -- Destination Port Num
|
|
wchXCDstChannelIdx } -- Destination Channel Num
|
|
::= { wchXCTable 1 }
|
|
|
|
|
|
WchXCEntry ::= SEQUENCE { wchXCSrcCpTypeIdx CpType,
|
|
wchXCSrcShelfIdx INTEGER,
|
|
wchXCSrcSlotIdx INTEGER,
|
|
wchXCSrcPortTypeIdx OlPortType,
|
|
wchXCSrcPortIdx INTEGER,
|
|
wchXCSrcChannelIdx INTEGER,
|
|
wchXCDstCpTypeIdx CpType,
|
|
wchXCDstShelfIdx INTEGER,
|
|
wchXCDstSlotIdx INTEGER,
|
|
wchXCDstPortTypeIdx OlPortType,
|
|
wchXCDstPortIdx INTEGER,
|
|
wchXCDstChannelIdx INTEGER,
|
|
wchXCServiceName DisplayString,
|
|
wchXCRowStatus RowStatus }
|
|
|
|
|
|
wchXCSrcCpTypeIdx OBJECT-TYPE
|
|
SYNTAX CpType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of circuit pack on which the source wavelength
|
|
channel of the cross-connection is located."
|
|
::= { wchXCEntry 1 }
|
|
|
|
|
|
wchXCSrcShelfIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (0|1|11|21|31)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the shelf on which the source wavelength
|
|
channel of the cross-connection is located."
|
|
::= { wchXCEntry 2 }
|
|
|
|
|
|
wchXCSrcSlotIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the slot on which the source wavelength
|
|
channel of the cross-connection is located."
|
|
::= { wchXCEntry 3 }
|
|
|
|
|
|
wchXCSrcPortTypeIdx OBJECT-TYPE
|
|
SYNTAX OlPortType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of port on which the source wavelength channel
|
|
of the cross-connection is located."
|
|
::= { wchXCEntry 4 }
|
|
|
|
|
|
wchXCSrcPortIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..600)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the port on which the source wavelength channel
|
|
of the cross-connection is located."
|
|
::= { wchXCEntry 5 }
|
|
|
|
|
|
wchXCSrcChannelIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (135..610)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The channel number of the source wavelength channel of the
|
|
cross-connection."
|
|
::= { wchXCEntry 6 }
|
|
|
|
|
|
wchXCDstCpTypeIdx OBJECT-TYPE
|
|
SYNTAX CpType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of circuit pack on which the destination wavelength
|
|
channel of the cross-connection is located."
|
|
::= { wchXCEntry 7 }
|
|
|
|
|
|
wchXCDstShelfIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (0|1|11|21|31)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the shelf on which the destination wavelength
|
|
channel of the cross-connection is located."
|
|
::= { wchXCEntry 8 }
|
|
|
|
|
|
wchXCDstSlotIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the slot on which the destination wavelength
|
|
channel of the cross-connection is located."
|
|
::= { wchXCEntry 9 }
|
|
|
|
|
|
wchXCDstPortTypeIdx OBJECT-TYPE
|
|
SYNTAX OlPortType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of port on which the destination wavelength channel
|
|
of the cross-connection is located."
|
|
::= { wchXCEntry 10 }
|
|
|
|
|
|
wchXCDstPortIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..600)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the port on which the destination wavelength
|
|
channel of the cross-connection is located."
|
|
::= { wchXCEntry 11 }
|
|
|
|
|
|
wchXCDstChannelIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (135..610)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The channel number of the destination wavelength channel
|
|
of the cross-connection."
|
|
::= { wchXCEntry 12 }
|
|
|
|
|
|
wchXCServiceName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Name of end-to-end wavelength service of which this cross-
|
|
connection is a part."
|
|
DEFVAL { "" }
|
|
::= { wchXCEntry 13 }
|
|
|
|
|
|
wchXCRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Used to control the addition and deletion of entries
|
|
in the wavelength channel cross-connection table."
|
|
::= { wchXCEntry 100 }
|
|
|
|
|
|
|
|
------------------------------------------------------------------------
|
|
-- The Wavelength Channel table is used to manage wavelength channel
|
|
-- objects which support provisioned wavelength channel cross-connections.
|
|
------------------------------------------------------------------------
|
|
|
|
wchTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WchEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table lists all managed wavelength channels on
|
|
equipment modules assigned to optical layer groupings."
|
|
::= { opticalLayer 10 }
|
|
|
|
|
|
wchEntry OBJECT-TYPE
|
|
SYNTAX WchEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The conceptual row object of the wavelength channel
|
|
table."
|
|
INDEX { wchCpTypeIdx, -- CP Type
|
|
wchShelfIdx, -- Shelf Num
|
|
wchSlotIdx, -- Slot Num
|
|
wchPortTypeIdx, -- Port Type
|
|
wchPortIdx, -- Port Num
|
|
wchIdx } -- Channel Num
|
|
::= { wchTable 1 }
|
|
|
|
|
|
WchEntry ::= SEQUENCE { wchCpTypeIdx CpType,
|
|
wchShelfIdx INTEGER,
|
|
wchSlotIdx INTEGER,
|
|
wchPortTypeIdx OlPortType,
|
|
wchPortIdx INTEGER,
|
|
wchIdx INTEGER,
|
|
wchAdminStatus AdminStatus,
|
|
wchOperStatus OperStatus,
|
|
wchOperStatQlfr OperStatQlfr,
|
|
wchAutoEnableTimer HoursAndMinutes,
|
|
wchActAutoEnableTimer HoursAndMinutes,
|
|
wchId DisplayString,
|
|
wchCustom1 DisplayString,
|
|
wchCustom2 DisplayString,
|
|
wchCustom3 DisplayString,
|
|
wchBitrate INTEGER,
|
|
wchGrid INTEGER,
|
|
wchWavelength FixedX100,
|
|
wchFrequency FixedX100,
|
|
wchRowStatus RowStatus }
|
|
|
|
|
|
wchCpTypeIdx OBJECT-TYPE
|
|
SYNTAX CpType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of circuit pack on which the wavelength channel
|
|
is located."
|
|
::= { wchEntry 1 }
|
|
|
|
|
|
wchShelfIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1|11|21|31)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the shelf on which the wavelength channel
|
|
is located."
|
|
::= { wchEntry 2 }
|
|
|
|
|
|
wchSlotIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..20)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the slot on which the wavelength channel
|
|
is located."
|
|
::= { wchEntry 3 }
|
|
|
|
|
|
wchPortTypeIdx OBJECT-TYPE
|
|
SYNTAX OlPortType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of port on which the wavelength channel is
|
|
located."
|
|
::= { wchEntry 4 }
|
|
|
|
|
|
wchPortIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the port on which the wavelength channel
|
|
is located."
|
|
::= { wchEntry 5 }
|
|
|
|
|
|
wchIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (135..610)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the targeted wavelength channel."
|
|
::= { wchEntry 6 }
|
|
|
|
|
|
wchAdminStatus OBJECT-TYPE
|
|
SYNTAX AdminStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The administrative status of the wavelength channel.
|
|
The default value is autoEnabled if the supporting WDM
|
|
is enabled or autoEnabled, otherwise it is disabled."
|
|
::= { wchEntry 7 }
|
|
|
|
|
|
wchOperStatus OBJECT-TYPE
|
|
SYNTAX OperStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The reported operational status of the wavelength channel."
|
|
::= { wchEntry 8 }
|
|
|
|
|
|
wchOperStatQlfr OBJECT-TYPE
|
|
SYNTAX OperStatQlfr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is a textual list of qualifiers about the reported
|
|
operational status of the wavelength channel."
|
|
::= { wchEntry 9 }
|
|
|
|
|
|
wchAutoEnableTimer OBJECT-TYPE
|
|
SYNTAX HoursAndMinutes
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Specifies the auto-enable timer for the targeted wavelength
|
|
channel. This value only applies if the wchAdminStatus object
|
|
is set to autoEnabled, in which case the default value is
|
|
008-00, otherwise, it is 000-00."
|
|
::= { wchEntry 10 }
|
|
|
|
|
|
wchActAutoEnableTimer OBJECT-TYPE
|
|
SYNTAX HoursAndMinutes
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the time remaining on the auto-enable timer if
|
|
it is actively counting down. Otherwise, the value returned
|
|
is 000-00."
|
|
::= { wchEntry 11 }
|
|
|
|
|
|
wchId OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Textual data recorded by the user to briefly identify the
|
|
wavelength channel object in a manner useful to the user."
|
|
DEFVAL { "" }
|
|
::= { wchEntry 12 }
|
|
|
|
|
|
wchCustom1 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "A variable length text string for operating company use."
|
|
DEFVAL { "" }
|
|
::= { wchEntry 13 }
|
|
|
|
|
|
wchCustom2 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "A variable length text string for operating company use."
|
|
DEFVAL { "" }
|
|
::= { wchEntry 14 }
|
|
|
|
|
|
wchCustom3 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "A variable length text string for operating company use."
|
|
DEFVAL { "" }
|
|
::= { wchEntry 15 }
|
|
|
|
|
|
wchBitrate OBJECT-TYPE
|
|
SYNTAX INTEGER { tenGig (1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The bitrate of the signal carried by the wavelength channel.
|
|
A value of tenGig applies to all signal bitrates of
|
|
10Gb/sec or less."
|
|
DEFVAL { tenGig }
|
|
::= { wchEntry 16 }
|
|
|
|
|
|
wchGrid OBJECT-TYPE
|
|
SYNTAX INTEGER { ghz100 (1),
|
|
ghz50 (2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The minimum grid spacing with which the channel is compatible."
|
|
DEFVAL { ghz100 }
|
|
::= { wchEntry 17 }
|
|
|
|
|
|
wchWavelength OBJECT-TYPE
|
|
SYNTAX FixedX100
|
|
UNITS "nanometers/100"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The wavelength of the channel."
|
|
::= { wchEntry 18 }
|
|
|
|
|
|
wchFrequency OBJECT-TYPE
|
|
SYNTAX FixedX100
|
|
UNITS "terahertz/100"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The frequency of the channel."
|
|
::= { wchEntry 19 }
|
|
|
|
|
|
wchRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "The Wavelength Channel table RowStatus object is not readable or
|
|
writeable because all entries in the Wavelength Channel table are
|
|
automatically created and deleted when an wavelength channel
|
|
cross-connection involving the wavelength channel is created or
|
|
deleted. This Wavelength Channel row status object is used only
|
|
in database change notifications to indicate if the row has
|
|
been created or deleted."
|
|
::= { wchEntry 100 }
|
|
|
|
|
|
------------------------------------------------------------------------
|
|
-- The objects of the Optical Layer Group Merge branch are used to invoke
|
|
-- an optical layer group merge operation.
|
|
------------------------------------------------------------------------
|
|
|
|
olGroupMerge OBJECT IDENTIFIER ::= { opticalLayer 11 }
|
|
|
|
olGroupMergeCmd OBJECT-TYPE
|
|
SYNTAX INTEGER { idle (1),
|
|
invoke (2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object is used to invoke an optical layer group
|
|
merge operation. The optical layer group merge is
|
|
activated when this object is set to invoke(2). The
|
|
values of the olGroupMergePrimary and olGroupMergeSecondary
|
|
objects must be set in the same set request as this object.
|
|
When a get is performed on this object, the value returned
|
|
is idle(1)."
|
|
::= { olGroupMerge 1 }
|
|
|
|
|
|
olGroupMergePrimary OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The identifier of the primary optical layer group
|
|
of the merge."
|
|
::= { olGroupMerge 2 }
|
|
|
|
|
|
olGroupMergeSecondary OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The identifier of the secondary optical layer group
|
|
of the merge."
|
|
::= { olGroupMerge 3 }
|
|
|
|
|
|
------------------------------------------------------------------------
|
|
-- The Optical Layer Performance branch contains all tables used to
|
|
-- access performance monitoring measurements and configuration for
|
|
-- monitored optical layer objects.
|
|
------------------------------------------------------------------------
|
|
|
|
olPerformance OBJECT IDENTIFIER ::= { opticalLayer 12 }
|
|
|
|
|
|
-----------------------------------------------------------------------
|
|
-- Objects used to retrieve current optical layer OSC
|
|
-- Performance Monitoring statistics.
|
|
-----------------------------------------------------------------------
|
|
|
|
|
|
olOSCCrntPMTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OlOSCCrntPMEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table of current performance monitoring statistics
|
|
collected for the optical layer OSC objects on the NE."
|
|
::= { olPerformance 1 }
|
|
|
|
|
|
olOSCCrntPMEntry OBJECT-TYPE
|
|
SYNTAX OlOSCCrntPMEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The row entry object of the optical layer OSC current
|
|
performance monitoring table. Each row of this table
|
|
contains a full set of PM statistics and related data
|
|
for a current measurement interval for a given optical
|
|
layer OSC object."
|
|
INDEX { olOSCCrntPMCpTypeIdx,
|
|
olOSCCrntPMShelfIdx,
|
|
olOSCCrntPMSlotIdx,
|
|
olOSCCrntPMLineIdx,
|
|
olOSCCrntPMIntervalTypeIdx }
|
|
::= { olOSCCrntPMTable 1 }
|
|
|
|
|
|
OlOSCCrntPMEntry ::= SEQUENCE { olOSCCrntPMCpTypeIdx CpType,
|
|
olOSCCrntPMShelfIdx INTEGER,
|
|
olOSCCrntPMSlotIdx INTEGER,
|
|
olOSCCrntPMLineIdx INTEGER,
|
|
olOSCCrntPMIntervalTypeIdx PMIntervalType,
|
|
olOSCCrntPMOPRValue FixedX10,
|
|
olOSCCrntPMOPRTimeStamp DateAndTime,
|
|
olOSCCrntPMOPRValidity PMValidity,
|
|
olOSCCrntPMOPTValue FixedX10,
|
|
olOSCCrntPMOPTTimeStamp DateAndTime,
|
|
olOSCCrntPMOPTValidity PMValidity,
|
|
olOSCCrntPMOBRValue FixedX10,
|
|
olOSCCrntPMOBRTimeStamp DateAndTime,
|
|
olOSCCrntPMOBRValidity PMValidity,
|
|
olOSCCrntPMCVSValue Unsigned32,
|
|
olOSCCrntPMCVSTimeStamp DateAndTime,
|
|
olOSCCrntPMCVSValidity PMValidity,
|
|
olOSCCrntPMCVSInitialize InitializeCmd,
|
|
olOSCCrntPMESSValue Unsigned32,
|
|
olOSCCrntPMESSTimeStamp DateAndTime,
|
|
olOSCCrntPMESSValidity PMValidity,
|
|
olOSCCrntPMESSInitialize InitializeCmd,
|
|
olOSCCrntPMSESSValue Unsigned32,
|
|
olOSCCrntPMSESSTimeStamp DateAndTime,
|
|
olOSCCrntPMSESSValidity PMValidity,
|
|
olOSCCrntPMSESSInitialize InitializeCmd,
|
|
olOSCCrntPMSEFSSValue Unsigned32,
|
|
olOSCCrntPMSEFSSTimeStamp DateAndTime,
|
|
olOSCCrntPMSEFSSValidity PMValidity,
|
|
olOSCCrntPMSEFSSInitialize InitializeCmd,
|
|
olOSCCrntPMUASSValue Unsigned32,
|
|
olOSCCrntPMUASSTimeStamp DateAndTime,
|
|
olOSCCrntPMUASSValidity PMValidity,
|
|
olOSCCrntPMUASSInitialize InitializeCmd }
|
|
|
|
|
|
olOSCCrntPMCpTypeIdx OBJECT-TYPE
|
|
SYNTAX CpType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of circuit pack on which the optical layer OSC
|
|
targeted for PMs is located."
|
|
::= { olOSCCrntPMEntry 1 }
|
|
|
|
|
|
olOSCCrntPMShelfIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1|11|21|31)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the shelf in which the optical layer OSC
|
|
targeted for PMs is located."
|
|
::= { olOSCCrntPMEntry 2 }
|
|
|
|
|
|
olOSCCrntPMSlotIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..20)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the slot in which the optical layer OSC
|
|
targeted for PMs is located."
|
|
::= { olOSCCrntPMEntry 3 }
|
|
|
|
|
|
olOSCCrntPMLineIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The line number of the OSC targeted for PMs."
|
|
::= { olOSCCrntPMEntry 4 }
|
|
|
|
|
|
olOSCCrntPMIntervalTypeIdx OBJECT-TYPE
|
|
SYNTAX PMIntervalType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of PM bin according to interval length."
|
|
::= { olOSCCrntPMEntry 5 }
|
|
|
|
|
|
olOSCCrntPMOPRValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The OSC optical power received on the Line port."
|
|
::= { olOSCCrntPMEntry 6 }
|
|
|
|
|
|
olOSCCrntPMOPRTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the optical power received value."
|
|
::= { olOSCCrntPMEntry 7 }
|
|
|
|
|
|
olOSCCrntPMOPRValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided optical power received
|
|
value."
|
|
::= { olOSCCrntPMEntry 8 }
|
|
|
|
|
|
olOSCCrntPMOPTValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The OSC optical power transmitted at the output of the
|
|
Line port."
|
|
::= { olOSCCrntPMEntry 9 }
|
|
|
|
|
|
olOSCCrntPMOPTTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the optical power transmitted
|
|
value."
|
|
::= { olOSCCrntPMEntry 10 }
|
|
|
|
|
|
olOSCCrntPMOPTValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided optical power
|
|
transmitted value."
|
|
::= { olOSCCrntPMEntry 11 }
|
|
|
|
|
|
olOSCCrntPMOBRValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dB/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The OSC optical back-reflected power."
|
|
::= { olOSCCrntPMEntry 12 }
|
|
|
|
|
|
olOSCCrntPMOBRTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the optical back-reflected
|
|
power value."
|
|
::= { olOSCCrntPMEntry 13 }
|
|
|
|
|
|
olOSCCrntPMOBRValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided optical back-reflected
|
|
power value."
|
|
::= { olOSCCrntPMEntry 14 }
|
|
|
|
|
|
olOSCCrntPMCVSValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The count of coding violations at the section layer of
|
|
the received OSC signal."
|
|
::= { olOSCCrntPMEntry 15 }
|
|
|
|
|
|
olOSCCrntPMCVSTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the section layer coding violations
|
|
value."
|
|
::= { olOSCCrntPMEntry 16 }
|
|
|
|
|
|
olOSCCrntPMCVSValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided section layer coding
|
|
violations value."
|
|
::= { olOSCCrntPMEntry 17 }
|
|
|
|
|
|
olOSCCrntPMCVSInitialize OBJECT-TYPE
|
|
SYNTAX InitializeCmd
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Used to initialize the value of the olOSCCrntPMCVSValue object
|
|
to 0."
|
|
::= { olOSCCrntPMEntry 18 }
|
|
|
|
|
|
olOSCCrntPMESSValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The count of errored seconds at the section layer of
|
|
the received OSC signal."
|
|
::= { olOSCCrntPMEntry 19 }
|
|
|
|
|
|
olOSCCrntPMESSTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the section layer errored seconds
|
|
value."
|
|
::= { olOSCCrntPMEntry 20 }
|
|
|
|
|
|
olOSCCrntPMESSValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided section layer errored
|
|
seconds value."
|
|
::= { olOSCCrntPMEntry 21 }
|
|
|
|
|
|
olOSCCrntPMESSInitialize OBJECT-TYPE
|
|
SYNTAX InitializeCmd
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Used to initialize the value of the olOSCCrntPMESSValue object
|
|
to 0."
|
|
::= { olOSCCrntPMEntry 22 }
|
|
|
|
|
|
olOSCCrntPMSESSValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The count of severely errored seconds at the section layer
|
|
of the received OSC signal."
|
|
::= { olOSCCrntPMEntry 23 }
|
|
|
|
|
|
olOSCCrntPMSESSTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the section layer severely errored
|
|
seconds value."
|
|
::= { olOSCCrntPMEntry 24 }
|
|
|
|
|
|
olOSCCrntPMSESSValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided section layer severely
|
|
errored seconds value."
|
|
::= { olOSCCrntPMEntry 25 }
|
|
|
|
|
|
olOSCCrntPMSESSInitialize OBJECT-TYPE
|
|
SYNTAX InitializeCmd
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Used to initialize the value of the olOSCCrntPMSESSValue object
|
|
to 0."
|
|
::= { olOSCCrntPMEntry 26 }
|
|
|
|
|
|
olOSCCrntPMSEFSSValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The count of severely errored framing seconds at the section
|
|
layer of the received OSC signal."
|
|
::= { olOSCCrntPMEntry 27 }
|
|
|
|
|
|
olOSCCrntPMSEFSSTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the section layer severely errored
|
|
framing seconds value."
|
|
::= { olOSCCrntPMEntry 28 }
|
|
|
|
|
|
olOSCCrntPMSEFSSValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided section layer severely
|
|
errored framing seconds value."
|
|
::= { olOSCCrntPMEntry 29 }
|
|
|
|
|
|
olOSCCrntPMSEFSSInitialize OBJECT-TYPE
|
|
SYNTAX InitializeCmd
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Used to initialize the value of the olOSCCrntPMSEFSSValue object
|
|
to 0."
|
|
::= { olOSCCrntPMEntry 30 }
|
|
|
|
|
|
olOSCCrntPMUASSValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The count of unavailable seconds at the section layer
|
|
of the received OSC signal."
|
|
::= { olOSCCrntPMEntry 31 }
|
|
|
|
|
|
olOSCCrntPMUASSTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the section layer unavailable
|
|
seconds value."
|
|
::= { olOSCCrntPMEntry 32 }
|
|
|
|
|
|
olOSCCrntPMUASSValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided section layer unavailable
|
|
seconds value."
|
|
::= { olOSCCrntPMEntry 33 }
|
|
|
|
|
|
olOSCCrntPMUASSInitialize OBJECT-TYPE
|
|
SYNTAX InitializeCmd
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Used to initialize the value of the olOSCCrntPMUASSValue
|
|
object to 0."
|
|
::= { olOSCCrntPMEntry 34 }
|
|
|
|
|
|
|
|
-----------------------------------------------------------------------
|
|
-- Objects used to retrieve historical Optical Layer OSC
|
|
-- Performance Monitoring statistics.
|
|
-----------------------------------------------------------------------
|
|
|
|
|
|
olOSCHistPMTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OlOSCHistPMEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table of historical performance monitoring statistics
|
|
collected for the optical layer OSC objects on the NE."
|
|
::= { olPerformance 2 }
|
|
|
|
|
|
olOSCHistPMEntry OBJECT-TYPE
|
|
SYNTAX OlOSCHistPMEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The row entry object of the optical layer OSC historical
|
|
performance monitoring table. Each row of this table
|
|
contains a full set of PM statistics and related data
|
|
for a historical measurement interval for a given optical
|
|
layer OSC object."
|
|
INDEX { olOSCHistPMCpTypeIdx,
|
|
olOSCHistPMShelfIdx,
|
|
olOSCHistPMSlotIdx,
|
|
olOSCHistPMLineIdx,
|
|
olOSCHistPMIntervalTypeIdx,
|
|
olOSCHistPMIntervalIdx }
|
|
::= { olOSCHistPMTable 1 }
|
|
|
|
|
|
OlOSCHistPMEntry ::= SEQUENCE { olOSCHistPMCpTypeIdx CpType,
|
|
olOSCHistPMShelfIdx INTEGER,
|
|
olOSCHistPMSlotIdx INTEGER,
|
|
olOSCHistPMLineIdx INTEGER,
|
|
olOSCHistPMIntervalTypeIdx PMIntervalType,
|
|
olOSCHistPMIntervalIdx INTEGER,
|
|
olOSCHistPMOPRValue FixedX10,
|
|
olOSCHistPMOPRTimeStamp DateAndTime,
|
|
olOSCHistPMOPRValidity PMValidity,
|
|
olOSCHistPMOPTValue FixedX10,
|
|
olOSCHistPMOPTTimeStamp DateAndTime,
|
|
olOSCHistPMOPTValidity PMValidity,
|
|
olOSCHistPMOBRValue FixedX10,
|
|
olOSCHistPMOBRTimeStamp DateAndTime,
|
|
olOSCHistPMOBRValidity PMValidity,
|
|
olOSCHistPMCVSValue Unsigned32,
|
|
olOSCHistPMCVSTimeStamp DateAndTime,
|
|
olOSCHistPMCVSValidity PMValidity,
|
|
olOSCHistPMCVSInitialize InitializeCmd,
|
|
olOSCHistPMESSValue Unsigned32,
|
|
olOSCHistPMESSTimeStamp DateAndTime,
|
|
olOSCHistPMESSValidity PMValidity,
|
|
olOSCHistPMESSInitialize InitializeCmd,
|
|
olOSCHistPMSESSValue Unsigned32,
|
|
olOSCHistPMSESSTimeStamp DateAndTime,
|
|
olOSCHistPMSESSValidity PMValidity,
|
|
olOSCHistPMSESSInitialize InitializeCmd,
|
|
olOSCHistPMSEFSSValue Unsigned32,
|
|
olOSCHistPMSEFSSTimeStamp DateAndTime,
|
|
olOSCHistPMSEFSSValidity PMValidity,
|
|
olOSCHistPMSEFSSInitialize InitializeCmd,
|
|
olOSCHistPMUASSValue Unsigned32,
|
|
olOSCHistPMUASSTimeStamp DateAndTime,
|
|
olOSCHistPMUASSValidity PMValidity,
|
|
olOSCHistPMUASSInitialize InitializeCmd }
|
|
|
|
|
|
olOSCHistPMCpTypeIdx OBJECT-TYPE
|
|
SYNTAX CpType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of circuit pack on which the optical layer OSC
|
|
targeted for PMs is located."
|
|
::= { olOSCHistPMEntry 1 }
|
|
|
|
|
|
olOSCHistPMShelfIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1|11|21|31)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the shelf in which the optical layer OSC
|
|
targeted for PMs is located."
|
|
::= { olOSCHistPMEntry 2 }
|
|
|
|
|
|
olOSCHistPMSlotIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..20)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the slot in which the optical layer OSC
|
|
targeted for PMs is located."
|
|
::= { olOSCHistPMEntry 3 }
|
|
|
|
|
|
olOSCHistPMLineIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The line number of the OSC targeted for PMs."
|
|
::= { olOSCHistPMEntry 4 }
|
|
|
|
|
|
olOSCHistPMIntervalTypeIdx OBJECT-TYPE
|
|
SYNTAX PMIntervalType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of PM bin according to interval length."
|
|
::= { olOSCHistPMEntry 5 }
|
|
|
|
|
|
olOSCHistPMIntervalIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..96)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The specific PM bin number. The range is 1 to 96 for the
|
|
15-minute historical bins. For the 1-day historical bin, the
|
|
value is 1."
|
|
::= { olOSCHistPMEntry 6 }
|
|
|
|
|
|
olOSCHistPMOPRValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The OSC optical power received on the Line port."
|
|
::= { olOSCHistPMEntry 7 }
|
|
|
|
|
|
olOSCHistPMOPRTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the optical power received value."
|
|
::= { olOSCHistPMEntry 8 }
|
|
|
|
|
|
olOSCHistPMOPRValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided optical power received
|
|
value."
|
|
::= { olOSCHistPMEntry 9 }
|
|
|
|
|
|
olOSCHistPMOPTValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The OSC optical power transmitted at the output of the
|
|
Line port."
|
|
::= { olOSCHistPMEntry 10 }
|
|
|
|
|
|
olOSCHistPMOPTTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the optical power transmitted
|
|
value."
|
|
::= { olOSCHistPMEntry 11 }
|
|
|
|
|
|
olOSCHistPMOPTValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided optical power
|
|
transmitted value."
|
|
::= { olOSCHistPMEntry 12 }
|
|
|
|
|
|
olOSCHistPMOBRValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The OSC optical back-reflected power."
|
|
::= { olOSCHistPMEntry 13 }
|
|
|
|
|
|
olOSCHistPMOBRTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the optical back-reflected
|
|
power value."
|
|
::= { olOSCHistPMEntry 14 }
|
|
|
|
|
|
olOSCHistPMOBRValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided optical back-reflected
|
|
power value."
|
|
::= { olOSCHistPMEntry 15 }
|
|
|
|
|
|
olOSCHistPMCVSValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The count of coding violations at the section layer of
|
|
the received OSC signal."
|
|
::= { olOSCHistPMEntry 16 }
|
|
|
|
|
|
olOSCHistPMCVSTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the section layer coding violations
|
|
value."
|
|
::= { olOSCHistPMEntry 17 }
|
|
|
|
|
|
olOSCHistPMCVSValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided section layer coding
|
|
violations value."
|
|
::= { olOSCHistPMEntry 18 }
|
|
|
|
|
|
olOSCHistPMCVSInitialize OBJECT-TYPE
|
|
SYNTAX InitializeCmd
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Used to initialize the value of the olOSCHistPMCVSValue object
|
|
to 0."
|
|
::= { olOSCHistPMEntry 19 }
|
|
|
|
|
|
olOSCHistPMESSValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The count of errored seconds at the section layer of
|
|
the received OSC signal."
|
|
::= { olOSCHistPMEntry 20 }
|
|
|
|
|
|
olOSCHistPMESSTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the section layer errored seconds
|
|
value."
|
|
::= { olOSCHistPMEntry 21 }
|
|
|
|
|
|
olOSCHistPMESSValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided section layer errored
|
|
seconds value."
|
|
::= { olOSCHistPMEntry 22 }
|
|
|
|
|
|
olOSCHistPMESSInitialize OBJECT-TYPE
|
|
SYNTAX InitializeCmd
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Used to initialize the value of the olOSCHistPMESSValue object
|
|
to 0."
|
|
::= { olOSCHistPMEntry 23 }
|
|
|
|
|
|
olOSCHistPMSESSValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The count of severely errored seconds at the section layer
|
|
of the received OSC signal."
|
|
::= { olOSCHistPMEntry 24 }
|
|
|
|
|
|
olOSCHistPMSESSTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the section layer severely errored
|
|
seconds value."
|
|
::= { olOSCHistPMEntry 25 }
|
|
|
|
|
|
olOSCHistPMSESSValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided section layer severely
|
|
errored seconds value."
|
|
::= { olOSCHistPMEntry 26 }
|
|
|
|
|
|
olOSCHistPMSESSInitialize OBJECT-TYPE
|
|
SYNTAX InitializeCmd
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Used to initialize the value of the olOSCHistPMSESSValue object
|
|
to 0."
|
|
::= { olOSCHistPMEntry 27 }
|
|
|
|
|
|
olOSCHistPMSEFSSValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The count of severely errored framing seconds at the section
|
|
layer of the received OSC signal."
|
|
::= { olOSCHistPMEntry 28 }
|
|
|
|
|
|
olOSCHistPMSEFSSTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the section layer severely errored
|
|
framing seconds value."
|
|
::= { olOSCHistPMEntry 29 }
|
|
|
|
|
|
olOSCHistPMSEFSSValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided section layer severely
|
|
errored framing seconds value."
|
|
::= { olOSCHistPMEntry 30 }
|
|
|
|
|
|
olOSCHistPMSEFSSInitialize OBJECT-TYPE
|
|
SYNTAX InitializeCmd
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Used to initialize the value of the olOSCHistPMSEFSSValue object
|
|
to 0."
|
|
::= { olOSCHistPMEntry 31 }
|
|
|
|
|
|
olOSCHistPMUASSValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The count of unavailable seconds at the section layer
|
|
of the received OSC signal."
|
|
::= { olOSCHistPMEntry 32 }
|
|
|
|
|
|
olOSCHistPMUASSTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the section layer unavailable
|
|
seconds value."
|
|
::= { olOSCHistPMEntry 33 }
|
|
|
|
|
|
olOSCHistPMUASSValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided section layer unavailable
|
|
seconds value."
|
|
::= { olOSCHistPMEntry 34 }
|
|
|
|
|
|
olOSCHistPMUASSInitialize OBJECT-TYPE
|
|
SYNTAX InitializeCmd
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Used to initialize the value of the olOSCHistPMUASSValue
|
|
object to 0."
|
|
::= { olOSCHistPMEntry 35 }
|
|
|
|
|
|
|
|
-----------------------------------------------------------------------
|
|
-- Objects used to manage Optical Layer OSC Performance
|
|
-- Monitoring Threshold Levels
|
|
-----------------------------------------------------------------------
|
|
|
|
|
|
olOSCPMThresholdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OlOSCPMThresholdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table of threshold levels for performance monitoring
|
|
counter values on Optical Layer OSC objects, that are
|
|
used in the generation of threshold crossing alerts."
|
|
::= { olPerformance 3 }
|
|
|
|
|
|
olOSCPMThresholdEntry OBJECT-TYPE
|
|
SYNTAX OlOSCPMThresholdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The row entry object of the optical layer OSC performance
|
|
monitoring threshold table. Each row of this table
|
|
contains a set of PM thresholds for a given interval
|
|
type that applies to an individual optical layer OSC
|
|
object."
|
|
INDEX { olOSCPMThresholdCpTypeIdx,
|
|
olOSCPMThresholdShelfIdx,
|
|
olOSCPMThresholdSlotIdx,
|
|
olOSCPMThresholdLineIdx,
|
|
olOSCPMThresholdIntervalTypeIdx }
|
|
::= { olOSCPMThresholdTable 1 }
|
|
|
|
|
|
OlOSCPMThresholdEntry ::= SEQUENCE { olOSCPMThresholdCpTypeIdx CpType,
|
|
olOSCPMThresholdShelfIdx INTEGER,
|
|
olOSCPMThresholdSlotIdx INTEGER,
|
|
olOSCPMThresholdLineIdx INTEGER,
|
|
olOSCPMThresholdIntervalTypeIdx PMIntervalType,
|
|
olOSCPMThresholdCVSValue Unsigned32,
|
|
olOSCPMThresholdESSValue Unsigned32,
|
|
olOSCPMThresholdSESSValue Unsigned32,
|
|
olOSCPMThresholdSEFSSValue Unsigned32,
|
|
olOSCPMThresholdUASSValue Unsigned32 }
|
|
|
|
|
|
olOSCPMThresholdCpTypeIdx OBJECT-TYPE
|
|
SYNTAX CpType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of circuit pack on which the optical layer
|
|
OSC targeted for PM thresholds is located."
|
|
::= { olOSCPMThresholdEntry 1 }
|
|
|
|
|
|
olOSCPMThresholdShelfIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1|11|21|31)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the shelf in which the optical layer
|
|
OSC targeted for PM thresholds is located."
|
|
::= { olOSCPMThresholdEntry 2 }
|
|
|
|
|
|
olOSCPMThresholdSlotIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..20)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the slot in which the optical layer OSC
|
|
targeted for PM thresholds is located."
|
|
::= { olOSCPMThresholdEntry 3 }
|
|
|
|
|
|
olOSCPMThresholdLineIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The line number of the OSC targeted for PM thresholds."
|
|
::= { olOSCPMThresholdEntry 4 }
|
|
|
|
|
|
olOSCPMThresholdIntervalTypeIdx OBJECT-TYPE
|
|
SYNTAX PMIntervalType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of PM bin according to interval length. Thresholds
|
|
are supported for the 15-minute and 1-day PM bins only."
|
|
::= { olOSCPMThresholdEntry 5 }
|
|
|
|
|
|
olOSCPMThresholdCVSValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The threshold for the count of coding violations at the
|
|
section layer."
|
|
::= { olOSCPMThresholdEntry 6 }
|
|
|
|
|
|
olOSCPMThresholdESSValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The threshold for the count of errored seconds at the
|
|
section layer."
|
|
::= { olOSCPMThresholdEntry 7 }
|
|
|
|
|
|
olOSCPMThresholdSESSValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The threshold for the count of severely errored seconds at the
|
|
section layer."
|
|
::= { olOSCPMThresholdEntry 8 }
|
|
|
|
|
|
olOSCPMThresholdSEFSSValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The threshold for the count of severely errored framing
|
|
seconds at the section layer."
|
|
::= { olOSCPMThresholdEntry 9 }
|
|
|
|
|
|
olOSCPMThresholdUASSValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The threshold for the count of unavailable seconds at the
|
|
section layer."
|
|
::= { olOSCPMThresholdEntry 10 }
|
|
|
|
|
|
|
|
-----------------------------------------------------------------------
|
|
-- Objects used to retrieve current Performance Monitoring statistics
|
|
-- for Optical Layer Ports.
|
|
-----------------------------------------------------------------------
|
|
|
|
|
|
olPortCrntPMTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OlPortCrntPMEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table of current performance monitoring statistics
|
|
collected for ports on equipment modules assigned
|
|
to optical layer groupings."
|
|
::= { olPerformance 4 }
|
|
|
|
|
|
olPortCrntPMEntry OBJECT-TYPE
|
|
SYNTAX OlPortCrntPMEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The row entry object of the optical layer port current
|
|
performance monitoring table. Each row of this table
|
|
contains a full set of PM statistics and related data
|
|
for a current measurement interval for a given optical
|
|
layer port."
|
|
INDEX { olPortCrntPMCpTypeIdx,
|
|
olPortCrntPMShelfIdx,
|
|
olPortCrntPMSlotIdx,
|
|
olPortCrntPMTypeIdx,
|
|
olPortCrntPMIdx,
|
|
olPortCrntPMIntervalTypeIdx }
|
|
::= { olPortCrntPMTable 1 }
|
|
|
|
|
|
OlPortCrntPMEntry ::= SEQUENCE { olPortCrntPMCpTypeIdx CpType,
|
|
olPortCrntPMShelfIdx INTEGER,
|
|
olPortCrntPMSlotIdx INTEGER,
|
|
olPortCrntPMTypeIdx OlPortType,
|
|
olPortCrntPMIdx INTEGER,
|
|
olPortCrntPMIntervalTypeIdx PMIntervalType,
|
|
olPortCrntPMOPRValue FixedX10,
|
|
olPortCrntPMOPRTimeStamp DateAndTime,
|
|
olPortCrntPMOPRValidity PMValidity,
|
|
olPortCrntPMOPRMinValue FixedX10,
|
|
olPortCrntPMOPRMinTimeStamp DateAndTime,
|
|
olPortCrntPMOPRMinValidity PMValidity,
|
|
olPortCrntPMOPRMaxValue FixedX10,
|
|
olPortCrntPMOPRMaxTimeStamp DateAndTime,
|
|
olPortCrntPMOPRMaxValidity PMValidity,
|
|
olPortCrntPMOPRAvgValue FixedX10,
|
|
olPortCrntPMOPRAvgTimeStamp DateAndTime,
|
|
olPortCrntPMOPRAvgValidity PMValidity,
|
|
olPortCrntPMOPRStdDevValue FixedX10,
|
|
olPortCrntPMOPRStdDevTimeStamp DateAndTime,
|
|
olPortCrntPMOPRStdDevValidity PMValidity,
|
|
olPortCrntPMOPTValue FixedX10,
|
|
olPortCrntPMOPTTimeStamp DateAndTime,
|
|
olPortCrntPMOPTValidity PMValidity,
|
|
olPortCrntPMOPTMinValue FixedX10,
|
|
olPortCrntPMOPTMinTimeStamp DateAndTime,
|
|
olPortCrntPMOPTMinValidity PMValidity,
|
|
olPortCrntPMOPTMaxValue FixedX10,
|
|
olPortCrntPMOPTMaxTimeStamp DateAndTime,
|
|
olPortCrntPMOPTMaxValidity PMValidity,
|
|
olPortCrntPMOPTAvgValue FixedX10,
|
|
olPortCrntPMOPTAvgTimeStamp DateAndTime,
|
|
olPortCrntPMOPTAvgValidity PMValidity,
|
|
olPortCrntPMOPTStdDevValue FixedX10,
|
|
olPortCrntPMOPTStdDevTimeStamp DateAndTime,
|
|
olPortCrntPMOPTStdDevValidity PMValidity,
|
|
olPortCrntPMLossRxValue FixedX10,
|
|
olPortCrntPMLossRxTimeStamp DateAndTime,
|
|
olPortCrntPMLossRxValidity PMValidity,
|
|
olPortCrntPMLossTxValue FixedX10,
|
|
olPortCrntPMLossTxTimeStamp DateAndTime,
|
|
olPortCrntPMLossTxValidity PMValidity,
|
|
olPortCrntPMInitializeAll InitializeCmd }
|
|
|
|
|
|
olPortCrntPMCpTypeIdx OBJECT-TYPE
|
|
SYNTAX CpType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of circuit pack on which the port
|
|
targeted for PMs is located."
|
|
::= { olPortCrntPMEntry 1 }
|
|
|
|
|
|
olPortCrntPMShelfIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1|11|21|31)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the shelf in which the port
|
|
targeted for PMs is located."
|
|
::= { olPortCrntPMEntry 2 }
|
|
|
|
|
|
olPortCrntPMSlotIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..20)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the slot in which the port
|
|
targeted for PMs is located."
|
|
::= { olPortCrntPMEntry 3 }
|
|
|
|
|
|
olPortCrntPMTypeIdx OBJECT-TYPE
|
|
SYNTAX OlPortType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of port targeted for PMs."
|
|
::= { olPortCrntPMEntry 4 }
|
|
|
|
|
|
olPortCrntPMIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the port of the specified
|
|
port type targeted for PMs."
|
|
::= { olPortCrntPMEntry 5 }
|
|
|
|
|
|
olPortCrntPMIntervalTypeIdx OBJECT-TYPE
|
|
SYNTAX PMIntervalType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of PM bin according to interval length."
|
|
::= { olPortCrntPMEntry 6 }
|
|
|
|
|
|
olPortCrntPMOPRValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The instantaneous optical power received on the port."
|
|
::= { olPortCrntPMEntry 7 }
|
|
|
|
|
|
olPortCrntPMOPRTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the instantaneous optical
|
|
power received value."
|
|
::= { olPortCrntPMEntry 8 }
|
|
|
|
|
|
olPortCrntPMOPRValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided instantaneous
|
|
optical power received value."
|
|
::= { olPortCrntPMEntry 9 }
|
|
|
|
|
|
olPortCrntPMOPRMinValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The minimum optical power received on the port over
|
|
the interval."
|
|
::= { olPortCrntPMEntry 10 }
|
|
|
|
|
|
olPortCrntPMOPRMinTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the minimum optical
|
|
power received value."
|
|
::= { olPortCrntPMEntry 11 }
|
|
|
|
|
|
olPortCrntPMOPRMinValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided minimum
|
|
optical power received value."
|
|
::= { olPortCrntPMEntry 12 }
|
|
|
|
|
|
olPortCrntPMOPRMaxValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The maximum optical power received on the port over
|
|
the interval."
|
|
::= { olPortCrntPMEntry 13 }
|
|
|
|
|
|
olPortCrntPMOPRMaxTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the maximum optical
|
|
power received value."
|
|
::= { olPortCrntPMEntry 14 }
|
|
|
|
|
|
olPortCrntPMOPRMaxValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided maximum
|
|
optical power received value."
|
|
::= { olPortCrntPMEntry 15 }
|
|
|
|
|
|
olPortCrntPMOPRAvgValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The average optical power received on the port over
|
|
the interval."
|
|
::= { olPortCrntPMEntry 16 }
|
|
|
|
|
|
olPortCrntPMOPRAvgTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the average optical
|
|
power received value."
|
|
::= { olPortCrntPMEntry 17 }
|
|
|
|
|
|
olPortCrntPMOPRAvgValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided average
|
|
optical power received value."
|
|
::= { olPortCrntPMEntry 18 }
|
|
|
|
|
|
olPortCrntPMOPRStdDevValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dB/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The standard deviation from the average of the optical
|
|
power received on the port over the interval."
|
|
::= { olPortCrntPMEntry 19 }
|
|
|
|
|
|
olPortCrntPMOPRStdDevTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the standard deviation value
|
|
for the optical power received."
|
|
::= { olPortCrntPMEntry 20 }
|
|
|
|
|
|
olPortCrntPMOPRStdDevValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided standard deviation
|
|
value for the optical power received."
|
|
::= { olPortCrntPMEntry 21 }
|
|
|
|
|
|
olPortCrntPMOPTValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The instantaneous optical power transmitted on the port."
|
|
::= { olPortCrntPMEntry 22 }
|
|
|
|
|
|
olPortCrntPMOPTTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the instantaneous optical
|
|
power transmitted value."
|
|
::= { olPortCrntPMEntry 23 }
|
|
|
|
|
|
olPortCrntPMOPTValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided instantaneous
|
|
optical power transmitted value."
|
|
::= { olPortCrntPMEntry 24 }
|
|
|
|
|
|
olPortCrntPMOPTMinValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The minimum optical power transmitted on the port over
|
|
the interval."
|
|
::= { olPortCrntPMEntry 25 }
|
|
|
|
|
|
olPortCrntPMOPTMinTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the minimum optical
|
|
power transmitted value."
|
|
::= { olPortCrntPMEntry 26 }
|
|
|
|
|
|
olPortCrntPMOPTMinValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided minimum
|
|
optical power transmitted value."
|
|
::= { olPortCrntPMEntry 27 }
|
|
|
|
|
|
olPortCrntPMOPTMaxValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The maximum optical power transmitted on the port over
|
|
the interval."
|
|
::= { olPortCrntPMEntry 28 }
|
|
|
|
|
|
olPortCrntPMOPTMaxTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the maximum optical
|
|
power transmitted value."
|
|
::= { olPortCrntPMEntry 29 }
|
|
|
|
|
|
olPortCrntPMOPTMaxValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided maximum
|
|
optical power transmitted value."
|
|
::= { olPortCrntPMEntry 30 }
|
|
|
|
|
|
olPortCrntPMOPTAvgValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The average optical power transmitted on the port over
|
|
the interval."
|
|
::= { olPortCrntPMEntry 31 }
|
|
|
|
|
|
olPortCrntPMOPTAvgTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the average optical
|
|
power transmitted value."
|
|
::= { olPortCrntPMEntry 32 }
|
|
|
|
|
|
olPortCrntPMOPTAvgValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided average
|
|
optical power transmitted value."
|
|
::= { olPortCrntPMEntry 33 }
|
|
|
|
|
|
olPortCrntPMOPTStdDevValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dB/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The standard deviation from the average of the optical
|
|
power transmitted on the port over the interval."
|
|
::= { olPortCrntPMEntry 34 }
|
|
|
|
|
|
olPortCrntPMOPTStdDevTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the standard deviation value
|
|
for the optical power transmitted."
|
|
::= { olPortCrntPMEntry 35 }
|
|
|
|
|
|
olPortCrntPMOPTStdDevValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided standard deviation
|
|
value for the optical power transmitted."
|
|
::= { olPortCrntPMEntry 36 }
|
|
|
|
|
|
olPortCrntPMLossRxValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dB/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The optical power loss measured on the port in the
|
|
receive direction. For a Line port, this represents
|
|
the span loss. For a DCM port, this is the DCM loss.
|
|
For a client port, this is the loss of the receive
|
|
inter-connection fiber."
|
|
::= { olPortCrntPMEntry 37 }
|
|
|
|
|
|
olPortCrntPMLossRxTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the receive loss value."
|
|
::= { olPortCrntPMEntry 38 }
|
|
|
|
|
|
olPortCrntPMLossRxValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided receive loss
|
|
value."
|
|
::= { olPortCrntPMEntry 39 }
|
|
|
|
|
|
olPortCrntPMLossTxValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dB/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The optical power loss measured on the port in the
|
|
transmit direction. For a Line port, this represents
|
|
the far-end span loss. For a client port, this is the
|
|
loss of the transmit inter-connection fiber."
|
|
::= { olPortCrntPMEntry 40 }
|
|
|
|
|
|
olPortCrntPMLossTxTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the transmit loss value."
|
|
::= { olPortCrntPMEntry 41 }
|
|
|
|
|
|
olPortCrntPMLossTxValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided transmit loss
|
|
value."
|
|
::= { olPortCrntPMEntry 42 }
|
|
|
|
|
|
olPortCrntPMInitializeAll OBJECT-TYPE
|
|
SYNTAX InitializeCmd
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Used to initialize all binned PM values for a given
|
|
entry in the table."
|
|
::= { olPortCrntPMEntry 43 }
|
|
|
|
|
|
|
|
-----------------------------------------------------------------------
|
|
-- Objects used to retrieve historical performance monitoring statistics
|
|
-- for ports on equipment modules assigned to optical layer groupings.
|
|
-----------------------------------------------------------------------
|
|
|
|
|
|
olPortHistPMTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OlPortHistPMEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table of historical performance monitoring statistics
|
|
collected for optical layer ports."
|
|
::= { olPerformance 5 }
|
|
|
|
|
|
olPortHistPMEntry OBJECT-TYPE
|
|
SYNTAX OlPortHistPMEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The row entry object of the Optical Layer Port
|
|
Historical Performance Monitoring table. Each row of
|
|
this table contains a full set of PM statistics and
|
|
related data for an historical measurement interval
|
|
for a given optical layer port."
|
|
INDEX { olPortHistPMCpTypeIdx,
|
|
olPortHistPMShelfIdx,
|
|
olPortHistPMSlotIdx,
|
|
olPortHistPMTypeIdx,
|
|
olPortHistPMIdx,
|
|
olPortHistPMIntervalTypeIdx,
|
|
olPortHistPMIntervalIdx }
|
|
::= { olPortHistPMTable 1 }
|
|
|
|
|
|
OlPortHistPMEntry ::= SEQUENCE { olPortHistPMCpTypeIdx CpType,
|
|
olPortHistPMShelfIdx INTEGER,
|
|
olPortHistPMSlotIdx INTEGER,
|
|
olPortHistPMTypeIdx OlPortType,
|
|
olPortHistPMIdx INTEGER,
|
|
olPortHistPMIntervalTypeIdx PMIntervalType,
|
|
olPortHistPMIntervalIdx INTEGER,
|
|
olPortHistPMOPRValue FixedX10,
|
|
olPortHistPMOPRTimeStamp DateAndTime,
|
|
olPortHistPMOPRValidity PMValidity,
|
|
olPortHistPMOPRMinValue FixedX10,
|
|
olPortHistPMOPRMinTimeStamp DateAndTime,
|
|
olPortHistPMOPRMinValidity PMValidity,
|
|
olPortHistPMOPRMaxValue FixedX10,
|
|
olPortHistPMOPRMaxTimeStamp DateAndTime,
|
|
olPortHistPMOPRMaxValidity PMValidity,
|
|
olPortHistPMOPRAvgValue FixedX10,
|
|
olPortHistPMOPRAvgTimeStamp DateAndTime,
|
|
olPortHistPMOPRAvgValidity PMValidity,
|
|
olPortHistPMOPRStdDevValue FixedX10,
|
|
olPortHistPMOPRStdDevTimeStamp DateAndTime,
|
|
olPortHistPMOPRStdDevValidity PMValidity,
|
|
olPortHistPMOPTValue FixedX10,
|
|
olPortHistPMOPTTimeStamp DateAndTime,
|
|
olPortHistPMOPTValidity PMValidity,
|
|
olPortHistPMOPTMinValue FixedX10,
|
|
olPortHistPMOPTMinTimeStamp DateAndTime,
|
|
olPortHistPMOPTMinValidity PMValidity,
|
|
olPortHistPMOPTMaxValue FixedX10,
|
|
olPortHistPMOPTMaxTimeStamp DateAndTime,
|
|
olPortHistPMOPTMaxValidity PMValidity,
|
|
olPortHistPMOPTAvgValue FixedX10,
|
|
olPortHistPMOPTAvgTimeStamp DateAndTime,
|
|
olPortHistPMOPTAvgValidity PMValidity,
|
|
olPortHistPMOPTStdDevValue FixedX10,
|
|
olPortHistPMOPTStdDevTimeStamp DateAndTime,
|
|
olPortHistPMOPTStdDevValidity PMValidity,
|
|
olPortHistPMLossRxValue FixedX10,
|
|
olPortHistPMLossRxTimeStamp DateAndTime,
|
|
olPortHistPMLossRxValidity PMValidity,
|
|
olPortHistPMLossTxValue FixedX10,
|
|
olPortHistPMLossTxTimeStamp DateAndTime,
|
|
olPortHistPMLossTxValidity PMValidity,
|
|
olPortHistPMInitializeAll InitializeCmd }
|
|
|
|
|
|
olPortHistPMCpTypeIdx OBJECT-TYPE
|
|
SYNTAX CpType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of circuit pack on which the port
|
|
targeted for PMs is located."
|
|
::= { olPortHistPMEntry 1 }
|
|
|
|
|
|
olPortHistPMShelfIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1|11|21|31)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the shelf in which the port
|
|
targeted for PMs is located."
|
|
::= { olPortHistPMEntry 2 }
|
|
|
|
|
|
olPortHistPMSlotIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..20)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the slot in which the port
|
|
targeted for PMs is located."
|
|
::= { olPortHistPMEntry 3 }
|
|
|
|
|
|
olPortHistPMTypeIdx OBJECT-TYPE
|
|
SYNTAX OlPortType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of port targeted for PMs."
|
|
::= { olPortHistPMEntry 4 }
|
|
|
|
|
|
olPortHistPMIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the port of the specified
|
|
port type targeted for PMs."
|
|
::= { olPortHistPMEntry 5 }
|
|
|
|
|
|
olPortHistPMIntervalTypeIdx OBJECT-TYPE
|
|
SYNTAX PMIntervalType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of PM bin according to interval length."
|
|
::= { olPortHistPMEntry 6 }
|
|
|
|
|
|
olPortHistPMIntervalIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..96)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The specific PM bin number. The range is 1 to 96 for the
|
|
15-minute historical bins. For the 1-day historical bin, the
|
|
value is 1."
|
|
::= { olPortHistPMEntry 7 }
|
|
|
|
|
|
olPortHistPMOPRValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The instantaneous optical power received on the port."
|
|
::= { olPortHistPMEntry 8 }
|
|
|
|
|
|
olPortHistPMOPRTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the instantaneous optical
|
|
power received value."
|
|
::= { olPortHistPMEntry 9 }
|
|
|
|
|
|
olPortHistPMOPRValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided instantaneous
|
|
optical power received value."
|
|
::= { olPortHistPMEntry 10 }
|
|
|
|
|
|
olPortHistPMOPRMinValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The minimum optical power received on the port over
|
|
the interval."
|
|
::= { olPortHistPMEntry 11 }
|
|
|
|
|
|
olPortHistPMOPRMinTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the minimum optical
|
|
power received value."
|
|
::= { olPortHistPMEntry 12 }
|
|
|
|
|
|
olPortHistPMOPRMinValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided minimum
|
|
optical power received value."
|
|
::= { olPortHistPMEntry 13 }
|
|
|
|
|
|
olPortHistPMOPRMaxValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The maximum optical power received on the port over
|
|
the interval."
|
|
::= { olPortHistPMEntry 14 }
|
|
|
|
|
|
olPortHistPMOPRMaxTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the maximum optical
|
|
power received value."
|
|
::= { olPortHistPMEntry 15 }
|
|
|
|
|
|
olPortHistPMOPRMaxValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided maximum
|
|
optical power received value."
|
|
::= { olPortHistPMEntry 16 }
|
|
|
|
|
|
olPortHistPMOPRAvgValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The average optical power received on the port over
|
|
the interval."
|
|
::= { olPortHistPMEntry 17 }
|
|
|
|
|
|
olPortHistPMOPRAvgTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the average optical
|
|
power received value."
|
|
::= { olPortHistPMEntry 18 }
|
|
|
|
|
|
olPortHistPMOPRAvgValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided average
|
|
optical power received value."
|
|
::= { olPortHistPMEntry 19 }
|
|
|
|
|
|
olPortHistPMOPRStdDevValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dB/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The standard deviation from the average of the optical
|
|
power received on the port over the interval."
|
|
::= { olPortHistPMEntry 20 }
|
|
|
|
|
|
olPortHistPMOPRStdDevTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the standard deviation value
|
|
for the optical power received."
|
|
::= { olPortHistPMEntry 21 }
|
|
|
|
|
|
olPortHistPMOPRStdDevValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided standard deviation
|
|
value for the optical power received."
|
|
::= { olPortHistPMEntry 22 }
|
|
|
|
|
|
olPortHistPMOPTValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The instantaneous optical power transmitted on the port."
|
|
::= { olPortHistPMEntry 23 }
|
|
|
|
|
|
olPortHistPMOPTTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the instantaneous optical
|
|
power transmitted value."
|
|
::= { olPortHistPMEntry 24 }
|
|
|
|
|
|
olPortHistPMOPTValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided instantaneous
|
|
optical power transmitted value."
|
|
::= { olPortHistPMEntry 25 }
|
|
|
|
|
|
olPortHistPMOPTMinValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The minimum optical power transmitted on the port over
|
|
the interval."
|
|
::= { olPortHistPMEntry 26 }
|
|
|
|
|
|
olPortHistPMOPTMinTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the minimum optical
|
|
power transmitted value."
|
|
::= { olPortHistPMEntry 27 }
|
|
|
|
|
|
olPortHistPMOPTMinValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided minimum
|
|
optical power transmitted value."
|
|
::= { olPortHistPMEntry 28 }
|
|
|
|
|
|
olPortHistPMOPTMaxValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The maximum optical power transmitted on the port over
|
|
the interval."
|
|
::= { olPortHistPMEntry 29 }
|
|
|
|
|
|
olPortHistPMOPTMaxTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the maximum optical
|
|
power transmitted value."
|
|
::= { olPortHistPMEntry 30 }
|
|
|
|
|
|
olPortHistPMOPTMaxValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided maximum
|
|
optical power transmitted value."
|
|
::= { olPortHistPMEntry 31 }
|
|
|
|
|
|
olPortHistPMOPTAvgValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The average optical power transmitted on the port over
|
|
the interval."
|
|
::= { olPortHistPMEntry 32 }
|
|
|
|
|
|
olPortHistPMOPTAvgTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the average optical
|
|
power transmitted value."
|
|
::= { olPortHistPMEntry 33 }
|
|
|
|
|
|
olPortHistPMOPTAvgValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided average
|
|
optical power transmitted value."
|
|
::= { olPortHistPMEntry 34 }
|
|
|
|
|
|
olPortHistPMOPTStdDevValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dB/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The standard deviation from the average of the optical
|
|
power transmitted on the port over the interval."
|
|
::= { olPortHistPMEntry 35 }
|
|
|
|
|
|
olPortHistPMOPTStdDevTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the standard deviation value
|
|
for the optical power transmitted."
|
|
::= { olPortHistPMEntry 36 }
|
|
|
|
|
|
olPortHistPMOPTStdDevValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided standard deviation
|
|
value for the optical power transmitted."
|
|
::= { olPortHistPMEntry 37 }
|
|
|
|
|
|
olPortHistPMLossRxValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dB/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The optical power loss measured on the port in the
|
|
receive direction. For a Line port, this represents
|
|
the span loss. For a DCM port, this is the DCM loss.
|
|
For a client port, this is the loss of the receive
|
|
inter-connection fiber."
|
|
::= { olPortHistPMEntry 38 }
|
|
|
|
|
|
olPortHistPMLossRxTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the receive loss value."
|
|
::= { olPortHistPMEntry 39 }
|
|
|
|
|
|
olPortHistPMLossRxValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided receive loss
|
|
value."
|
|
::= { olPortHistPMEntry 40 }
|
|
|
|
|
|
olPortHistPMLossTxValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dB/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The optical power loss measured on the port in the
|
|
transmit direction. For a Line port, this represents
|
|
the far-end span loss. For a client port, this is the
|
|
loss of the transmit inter-connection fiber."
|
|
::= { olPortHistPMEntry 41 }
|
|
|
|
|
|
olPortHistPMLossTxTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the transmit loss value."
|
|
::= { olPortHistPMEntry 42 }
|
|
|
|
|
|
olPortHistPMLossTxValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided transmit loss
|
|
value."
|
|
::= { olPortHistPMEntry 43 }
|
|
|
|
|
|
olPortHistPMInitializeAll OBJECT-TYPE
|
|
SYNTAX InitializeCmd
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Used to initialize all binned PM values for a given
|
|
entry in the table."
|
|
::= { olPortHistPMEntry 44 }
|
|
|
|
|
|
|
|
-----------------------------------------------------------------------
|
|
-- Objects used to retrieve current performance monitoring statistics
|
|
-- for wavelength channels on equipment modules assigned to optical
|
|
-- layer groupings.
|
|
-----------------------------------------------------------------------
|
|
|
|
|
|
wchCrntPMTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WchCrntPMEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table of current performance monitoring statistics
|
|
collected for wavelength channels."
|
|
::= { olPerformance 6 }
|
|
|
|
|
|
wchCrntPMEntry OBJECT-TYPE
|
|
SYNTAX WchCrntPMEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The row entry object of the Wavelength Channel Current
|
|
Performance Monitoring table. Each row of this table
|
|
contains a full set of PM statistics and related data
|
|
for a current measurement interval for a wavelength
|
|
channel object in an optical layer grouping."
|
|
INDEX { wchCrntPMCpTypeIdx,
|
|
wchCrntPMShelfIdx,
|
|
wchCrntPMSlotIdx,
|
|
wchCrntPMPortTypeIdx,
|
|
wchCrntPMPortIdx,
|
|
wchCrntPMIdx,
|
|
wchCrntPMIntervalTypeIdx }
|
|
::= { wchCrntPMTable 1 }
|
|
|
|
|
|
WchCrntPMEntry ::= SEQUENCE { wchCrntPMCpTypeIdx CpType,
|
|
wchCrntPMShelfIdx INTEGER,
|
|
wchCrntPMSlotIdx INTEGER,
|
|
wchCrntPMPortTypeIdx OlPortType,
|
|
wchCrntPMPortIdx INTEGER,
|
|
wchCrntPMIdx INTEGER,
|
|
wchCrntPMIntervalTypeIdx PMIntervalType,
|
|
wchCrntPMOPRValue FixedX10,
|
|
wchCrntPMOPRTimeStamp DateAndTime,
|
|
wchCrntPMOPRValidity PMValidity,
|
|
wchCrntPMOPRMinValue FixedX10,
|
|
wchCrntPMOPRMinTimeStamp DateAndTime,
|
|
wchCrntPMOPRMinValidity PMValidity,
|
|
wchCrntPMOPRMinInitialize InitializeCmd,
|
|
wchCrntPMOPRMaxValue FixedX10,
|
|
wchCrntPMOPRMaxTimeStamp DateAndTime,
|
|
wchCrntPMOPRMaxValidity PMValidity,
|
|
wchCrntPMOPRMaxInitialize InitializeCmd,
|
|
wchCrntPMOPTValue FixedX10,
|
|
wchCrntPMOPTTimeStamp DateAndTime,
|
|
wchCrntPMOPTValidity PMValidity,
|
|
wchCrntPMOPTMinValue FixedX10,
|
|
wchCrntPMOPTMinTimeStamp DateAndTime,
|
|
wchCrntPMOPTMinValidity PMValidity,
|
|
wchCrntPMOPTMinInitialize InitializeCmd,
|
|
wchCrntPMOPTMaxValue FixedX10,
|
|
wchCrntPMOPTMaxTimeStamp DateAndTime,
|
|
wchCrntPMOPTMaxValidity PMValidity,
|
|
wchCrntPMOPTMaxInitialize InitializeCmd }
|
|
|
|
|
|
wchCrntPMCpTypeIdx OBJECT-TYPE
|
|
SYNTAX CpType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of circuit pack on which the wavelength channel
|
|
targeted for PMs is located."
|
|
::= { wchCrntPMEntry 1 }
|
|
|
|
|
|
wchCrntPMShelfIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1|11|21|31)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the shelf in which the wavelength channel
|
|
targeted for PMs is located."
|
|
::= { wchCrntPMEntry 2 }
|
|
|
|
|
|
wchCrntPMSlotIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..20)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the slot in which the wavelength channel
|
|
targeted for PMs is located."
|
|
::= { wchCrntPMEntry 3 }
|
|
|
|
|
|
wchCrntPMPortTypeIdx OBJECT-TYPE
|
|
SYNTAX OlPortType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of port in which the wavelength channel targeted
|
|
for PMs is located."
|
|
::= { wchCrntPMEntry 4 }
|
|
|
|
|
|
wchCrntPMPortIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the port of the specified port type in
|
|
which the wavelength channel targeted for PMs is located."
|
|
::= { wchCrntPMEntry 5 }
|
|
|
|
|
|
wchCrntPMIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (135..610)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the wavelength channel targeted for PMs."
|
|
::= { wchCrntPMEntry 6 }
|
|
|
|
|
|
wchCrntPMIntervalTypeIdx OBJECT-TYPE
|
|
SYNTAX PMIntervalType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of PM bin according to interval length."
|
|
::= { wchCrntPMEntry 7 }
|
|
|
|
|
|
wchCrntPMOPRValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The instantaneous optical power received on the
|
|
channel."
|
|
::= { wchCrntPMEntry 8 }
|
|
|
|
|
|
wchCrntPMOPRTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the instantaneous optical
|
|
power received value."
|
|
::= { wchCrntPMEntry 9 }
|
|
|
|
|
|
wchCrntPMOPRValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided instantaneous
|
|
optical power received value."
|
|
::= { wchCrntPMEntry 10 }
|
|
|
|
|
|
wchCrntPMOPRMinValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The minimum optical power received on the channel
|
|
over the interval. Can be set to the value 0 to initialize."
|
|
::= { wchCrntPMEntry 11 }
|
|
|
|
|
|
wchCrntPMOPRMinTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the minimum optical
|
|
power received value."
|
|
::= { wchCrntPMEntry 12 }
|
|
|
|
|
|
wchCrntPMOPRMinValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided minimum
|
|
optical power received value."
|
|
::= { wchCrntPMEntry 13 }
|
|
|
|
|
|
wchCrntPMOPRMinInitialize OBJECT-TYPE
|
|
SYNTAX InitializeCmd
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Used to initialize the value of the wchCrntPMOPRMinValue
|
|
object."
|
|
::= { wchCrntPMEntry 14 }
|
|
|
|
|
|
wchCrntPMOPRMaxValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The maximum optical power received on the
|
|
channel over the interval. Can be set to the
|
|
value 0 to initialize."
|
|
::= { wchCrntPMEntry 15 }
|
|
|
|
|
|
wchCrntPMOPRMaxTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the maximum optical
|
|
power received value."
|
|
::= { wchCrntPMEntry 16 }
|
|
|
|
|
|
wchCrntPMOPRMaxValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided maximum
|
|
optical power received value."
|
|
::= { wchCrntPMEntry 17 }
|
|
|
|
|
|
wchCrntPMOPRMaxInitialize OBJECT-TYPE
|
|
SYNTAX InitializeCmd
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Used to initialize the value of the wchCrntPMOPRMaxValue
|
|
object."
|
|
::= { wchCrntPMEntry 18 }
|
|
|
|
|
|
wchCrntPMOPTValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The instantaneous optical power transmitted on the
|
|
channel."
|
|
::= { wchCrntPMEntry 19 }
|
|
|
|
|
|
wchCrntPMOPTTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the instantaneous optical
|
|
power transmitted value."
|
|
::= { wchCrntPMEntry 20 }
|
|
|
|
|
|
wchCrntPMOPTValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided instantaneous
|
|
optical power transmitted value."
|
|
::= { wchCrntPMEntry 21 }
|
|
|
|
|
|
wchCrntPMOPTMinValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The minimum optical power transmitted on the channel
|
|
over the interval. Can be set to the value 0 to initialize."
|
|
::= { wchCrntPMEntry 22 }
|
|
|
|
|
|
wchCrntPMOPTMinTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the minimum optical
|
|
power transmitted value."
|
|
::= { wchCrntPMEntry 23 }
|
|
|
|
|
|
wchCrntPMOPTMinValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided minimum
|
|
optical power transmitted value."
|
|
::= { wchCrntPMEntry 24 }
|
|
|
|
|
|
wchCrntPMOPTMinInitialize OBJECT-TYPE
|
|
SYNTAX InitializeCmd
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Used to initialize the value of the wchCrntPMOPTMinValue
|
|
object."
|
|
::= { wchCrntPMEntry 25 }
|
|
|
|
|
|
wchCrntPMOPTMaxValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The maximum optical power transmitted on the channel
|
|
over the interval. Can be set to the value 0 to initialize."
|
|
::= { wchCrntPMEntry 26 }
|
|
|
|
|
|
wchCrntPMOPTMaxTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the maximum optical
|
|
power transmitted value."
|
|
::= { wchCrntPMEntry 27 }
|
|
|
|
|
|
wchCrntPMOPTMaxValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided maximum
|
|
optical power transmitted value."
|
|
::= { wchCrntPMEntry 28 }
|
|
|
|
|
|
wchCrntPMOPTMaxInitialize OBJECT-TYPE
|
|
SYNTAX InitializeCmd
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Used to initialize the value of the wchCrntPMOPTMaxValue
|
|
object."
|
|
::= { wchCrntPMEntry 29 }
|
|
|
|
|
|
|
|
-----------------------------------------------------------------------
|
|
-- Objects used to retrieve historical performance monitoring
|
|
-- statistics for wavelength channels on equipment modules assigned
|
|
-- to optical layer groupings.
|
|
-----------------------------------------------------------------------
|
|
|
|
|
|
wchHistPMTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WchHistPMEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table of historical performance monitoring statistics
|
|
collected for wavelength channels."
|
|
::= { olPerformance 7 }
|
|
|
|
|
|
wchHistPMEntry OBJECT-TYPE
|
|
SYNTAX WchHistPMEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The row entry object of the Wavelength Channel
|
|
Historical Performance Monitoring table. Each row of
|
|
this table contains a full set of PM statistics and
|
|
related data for a wavelength channel object in an
|
|
optical layer grouping."
|
|
INDEX { wchHistPMCpTypeIdx,
|
|
wchHistPMShelfIdx,
|
|
wchHistPMSlotIdx,
|
|
wchHistPMPortTypeIdx,
|
|
wchHistPMPortIdx,
|
|
wchHistPMIdx,
|
|
wchHistPMIntervalTypeIdx,
|
|
wchHistPMIntervalIdx }
|
|
::= { wchHistPMTable 1 }
|
|
|
|
|
|
WchHistPMEntry ::= SEQUENCE { wchHistPMCpTypeIdx CpType,
|
|
wchHistPMShelfIdx INTEGER,
|
|
wchHistPMSlotIdx INTEGER,
|
|
wchHistPMPortTypeIdx OlPortType,
|
|
wchHistPMPortIdx INTEGER,
|
|
wchHistPMIdx INTEGER,
|
|
wchHistPMIntervalTypeIdx PMIntervalType,
|
|
wchHistPMIntervalIdx INTEGER,
|
|
wchHistPMOPRValue FixedX10,
|
|
wchHistPMOPRTimeStamp DateAndTime,
|
|
wchHistPMOPRValidity PMValidity,
|
|
wchHistPMOPRMinValue FixedX10,
|
|
wchHistPMOPRMinTimeStamp DateAndTime,
|
|
wchHistPMOPRMinValidity PMValidity,
|
|
wchHistPMOPRMinInitialize InitializeCmd,
|
|
wchHistPMOPRMaxValue FixedX10,
|
|
wchHistPMOPRMaxTimeStamp DateAndTime,
|
|
wchHistPMOPRMaxValidity PMValidity,
|
|
wchHistPMOPRMaxInitialize InitializeCmd,
|
|
wchHistPMOPTValue FixedX10,
|
|
wchHistPMOPTTimeStamp DateAndTime,
|
|
wchHistPMOPTValidity PMValidity,
|
|
wchHistPMOPTMinValue FixedX10,
|
|
wchHistPMOPTMinTimeStamp DateAndTime,
|
|
wchHistPMOPTMinValidity PMValidity,
|
|
wchHistPMOPTMinInitialize InitializeCmd,
|
|
wchHistPMOPTMaxValue FixedX10,
|
|
wchHistPMOPTMaxTimeStamp DateAndTime,
|
|
wchHistPMOPTMaxValidity PMValidity,
|
|
wchHistPMOPTMaxInitialize InitializeCmd }
|
|
|
|
|
|
wchHistPMCpTypeIdx OBJECT-TYPE
|
|
SYNTAX CpType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of circuit pack on which the wavelength channel
|
|
targeted for PMs is located."
|
|
::= { wchHistPMEntry 1 }
|
|
|
|
|
|
wchHistPMShelfIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1|11|21|31)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the shelf in which the wavelength channel
|
|
targeted for PMs is located."
|
|
::= { wchHistPMEntry 2 }
|
|
|
|
|
|
wchHistPMSlotIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..20)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the slot in which the wavelength channel
|
|
targeted for PMs is located."
|
|
::= { wchHistPMEntry 3 }
|
|
|
|
|
|
wchHistPMPortTypeIdx OBJECT-TYPE
|
|
SYNTAX OlPortType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of port in which the wavelength channel targeted
|
|
for PMs is located."
|
|
::= { wchHistPMEntry 4 }
|
|
|
|
|
|
wchHistPMPortIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the port of the specified port type in
|
|
which the wavelength channel targeted for PMs is located."
|
|
::= { wchHistPMEntry 5 }
|
|
|
|
|
|
wchHistPMIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (135..610)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the wavelength channel targeted for PMs."
|
|
::= { wchHistPMEntry 6 }
|
|
|
|
|
|
wchHistPMIntervalTypeIdx OBJECT-TYPE
|
|
SYNTAX PMIntervalType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The type of PM bin according to interval length."
|
|
::= { wchHistPMEntry 7 }
|
|
|
|
|
|
wchHistPMIntervalIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..96)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The specific PM bin number. The range is 1 to 96 for the
|
|
15-minute historical bins. For the 1-day historical bin, the
|
|
value is 1."
|
|
::= { wchHistPMEntry 8 }
|
|
|
|
|
|
wchHistPMOPRValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The instantaneous optical power received on the
|
|
channel."
|
|
::= { wchHistPMEntry 9 }
|
|
|
|
|
|
wchHistPMOPRTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the instantaneous optical
|
|
power received value."
|
|
::= { wchHistPMEntry 10 }
|
|
|
|
|
|
wchHistPMOPRValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided instantaneous
|
|
optical power received value."
|
|
::= { wchHistPMEntry 11 }
|
|
|
|
|
|
wchHistPMOPRMinValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The minimum optical power received on the channel
|
|
over the interval. Can be set to the value 0 to initialize
|
|
the object."
|
|
::= { wchHistPMEntry 12 }
|
|
|
|
|
|
wchHistPMOPRMinTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the minimum optical
|
|
power received value."
|
|
::= { wchHistPMEntry 13 }
|
|
|
|
|
|
wchHistPMOPRMinValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided minimum
|
|
optical power received value."
|
|
::= { wchHistPMEntry 14 }
|
|
|
|
|
|
wchHistPMOPRMinInitialize OBJECT-TYPE
|
|
SYNTAX InitializeCmd
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Used to initialize the value of the wchHistPMOPRMinValue
|
|
object."
|
|
::= { wchHistPMEntry 15 }
|
|
|
|
|
|
wchHistPMOPRMaxValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The maximum optical power received on the
|
|
channel over the interval. Can be set to the
|
|
value 0 to initialize the object."
|
|
::= { wchHistPMEntry 16 }
|
|
|
|
|
|
wchHistPMOPRMaxTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the maximum optical
|
|
power received value."
|
|
::= { wchHistPMEntry 17 }
|
|
|
|
|
|
wchHistPMOPRMaxValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided maximum
|
|
optical power received value."
|
|
::= { wchHistPMEntry 18 }
|
|
|
|
|
|
wchHistPMOPRMaxInitialize OBJECT-TYPE
|
|
SYNTAX InitializeCmd
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Used to initialize the value of the wchHistPMOPRMaxValue
|
|
object."
|
|
::= { wchHistPMEntry 19 }
|
|
|
|
|
|
wchHistPMOPTValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The instantaneous optical power transmitted on the
|
|
channel."
|
|
::= { wchHistPMEntry 20 }
|
|
|
|
|
|
wchHistPMOPTTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the instantaneous optical
|
|
power transmitted value."
|
|
::= { wchHistPMEntry 21 }
|
|
|
|
|
|
wchHistPMOPTValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided instantaneous
|
|
optical power transmitted value."
|
|
::= { wchHistPMEntry 22 }
|
|
|
|
|
|
wchHistPMOPTMinValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The minimum optical power transmitted on the channel
|
|
over the interval. Can be set to the value 0 to initialize
|
|
the object."
|
|
::= { wchHistPMEntry 23 }
|
|
|
|
|
|
wchHistPMOPTMinTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the minimum optical
|
|
power transmitted value."
|
|
::= { wchHistPMEntry 24 }
|
|
|
|
|
|
wchHistPMOPTMinValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided minimum
|
|
optical power transmitted value."
|
|
::= { wchHistPMEntry 25 }
|
|
|
|
|
|
wchHistPMOPTMinInitialize OBJECT-TYPE
|
|
SYNTAX InitializeCmd
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Used to initialize the value of the wchHistPMOPTMinValue
|
|
object."
|
|
::= { wchHistPMEntry 26 }
|
|
|
|
|
|
wchHistPMOPTMaxValue OBJECT-TYPE
|
|
SYNTAX FixedX10
|
|
UNITS "dBm/10"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The maximum optical power transmitted on the channel
|
|
over the interval. Can be set to the value 0 to initialize
|
|
the object."
|
|
::= { wchHistPMEntry 27 }
|
|
|
|
|
|
wchHistPMOPTMaxTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time stamp of the maximum optical
|
|
power transmitted value."
|
|
::= { wchHistPMEntry 28 }
|
|
|
|
|
|
wchHistPMOPTMaxValidity OBJECT-TYPE
|
|
SYNTAX PMValidity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the validity of the provided maximum
|
|
optical power transmitted value."
|
|
::= { wchHistPMEntry 29 }
|
|
|
|
|
|
wchHistPMOPTMaxInitialize OBJECT-TYPE
|
|
SYNTAX InitializeCmd
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Used to initialize the value of the wchHistPMOPTMaxValue
|
|
object."
|
|
::= { wchHistPMEntry 30 }
|
|
|
|
|
|
|
|
-----------------------------------------------------------------------
|
|
-- Optical Layer Trap Definitions.
|
|
-----------------------------------------------------------------------
|
|
|
|
olOSCEvtNotifications OBJECT IDENTIFIER ::= { olEvtNotifications 1 }
|
|
olPortEvtNotifications OBJECT IDENTIFIER ::= { olEvtNotifications 2 }
|
|
wdmEvtNotifications OBJECT IDENTIFIER ::= { olEvtNotifications 3 }
|
|
wchEvtNotifications OBJECT IDENTIFIER ::= { olEvtNotifications 4 }
|
|
|
|
olOSCCondNotifications OBJECT IDENTIFIER ::= { olCondNotifications 1 }
|
|
olPortCondNotifications OBJECT IDENTIFIER ::= { olCondNotifications 2 }
|
|
wdmCondNotifications OBJECT IDENTIFIER ::= { olCondNotifications 3 }
|
|
wchCondNotifications OBJECT IDENTIFIER ::= { olCondNotifications 4 }
|
|
|
|
|
|
-----------------------------------------------------------------------
|
|
-- Optical Layer Event Traps.
|
|
-----------------------------------------------------------------------
|
|
|
|
|
|
olOSCStatusChangeEvt NOTIFICATION-TYPE
|
|
OBJECTS { olOSCCpTypeIdx,
|
|
olOSCShelfIdx,
|
|
olOSCSlotIdx,
|
|
olOSCLineIdx,
|
|
olOSCOperStatus,
|
|
olOSCOperStatQlfr,
|
|
evtDateAndTime,
|
|
trapSeqNum,
|
|
evtDescription,
|
|
evtObjectType,
|
|
evtCodeType }
|
|
STATUS current
|
|
DESCRIPTION "Notification of a change in the operational status or
|
|
operational status qualifier or an optical layer OSC
|
|
facility."
|
|
::= { olOSCEvtNotifications 0 1 }
|
|
|
|
|
|
olOSCTcaEvt NOTIFICATION-TYPE
|
|
OBJECTS { olOSCCpTypeIdx,
|
|
olOSCShelfIdx,
|
|
olOSCSlotIdx,
|
|
olOSCLineIdx,
|
|
tcaIntervalType,
|
|
tcaDateAndTime,
|
|
tcaMontype,
|
|
tcaValue,
|
|
tcaThreshold,
|
|
evtDateAndTime,
|
|
trapSeqNum,
|
|
evtDescription,
|
|
evtObjectType,
|
|
evtCodeType }
|
|
STATUS current
|
|
DESCRIPTION "This trap provides a threshold crossing alert for a
|
|
performance monitoring statistic on an optical layer
|
|
OSC facility."
|
|
::= { olOSCEvtNotifications 0 2 }
|
|
|
|
|
|
|
|
olPortStatusChangeEvt NOTIFICATION-TYPE
|
|
OBJECTS { olPortCpTypeIdx,
|
|
olPortShelfIdx,
|
|
olPortSlotIdx,
|
|
olPortTypeIdx,
|
|
olPortIdx,
|
|
olPortOperStatus,
|
|
olPortOperStatQlfr,
|
|
evtDateAndTime,
|
|
trapSeqNum,
|
|
evtDescription,
|
|
evtObjectType,
|
|
evtCodeType }
|
|
STATUS current
|
|
DESCRIPTION "Notification of a change in the operational status or
|
|
operational status qualifier or an optical layer port."
|
|
::= { olPortEvtNotifications 0 1 }
|
|
|
|
|
|
wdmStatusChangeEvt NOTIFICATION-TYPE
|
|
OBJECTS { wdmCpTypeIdx,
|
|
wdmShelfIdx,
|
|
wdmSlotIdx,
|
|
wdmLineIdx,
|
|
olPortIdx,
|
|
wdmOperStatus,
|
|
wdmOperStatQlfr,
|
|
evtDateAndTime,
|
|
trapSeqNum,
|
|
evtDescription,
|
|
evtObjectType,
|
|
evtCodeType }
|
|
STATUS current
|
|
DESCRIPTION "Notification of a change in the operational status or
|
|
operational status qualifier or an optical layer WDM
|
|
object."
|
|
::= { wdmEvtNotifications 0 1 }
|
|
|
|
|
|
wchStatusChangeEvt NOTIFICATION-TYPE
|
|
OBJECTS { wchCpTypeIdx,
|
|
wchShelfIdx,
|
|
wchSlotIdx,
|
|
wchPortTypeIdx,
|
|
wchPortIdx,
|
|
wchIdx,
|
|
wchOperStatus,
|
|
wchOperStatQlfr,
|
|
evtDateAndTime,
|
|
trapSeqNum,
|
|
evtDescription,
|
|
evtObjectType,
|
|
evtCodeType }
|
|
STATUS current
|
|
DESCRIPTION "Notification of a change in the operational status or
|
|
operational status qualifier or an optical layer WDM
|
|
object."
|
|
::= { wchEvtNotifications 0 1 }
|
|
|
|
|
|
|
|
-----------------------------------------------------------------------
|
|
-- Optical Layer Condition Traps.
|
|
-----------------------------------------------------------------------
|
|
|
|
|
|
olOSCLossOfLightRxCond NOTIFICATION-TYPE
|
|
OBJECTS { olOSCCpTypeIdx,
|
|
olOSCShelfIdx,
|
|
olOSCSlotIdx,
|
|
olOSCLineIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "There is no input signal detected for the identified OSC."
|
|
::= { olOSCCondNotifications 0 1 }
|
|
|
|
|
|
olOSCLossOfLightRxClear NOTIFICATION-TYPE
|
|
OBJECTS { olOSCCpTypeIdx,
|
|
olOSCShelfIdx,
|
|
olOSCSlotIdx,
|
|
olOSCLineIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active optical layer OSC Receive Loss of Light
|
|
condition has cleared."
|
|
::= { olOSCCondNotifications 0 2 }
|
|
|
|
|
|
olOSCLossOfFrameCond NOTIFICATION-TYPE
|
|
OBJECTS { olOSCCpTypeIdx,
|
|
olOSCShelfIdx,
|
|
olOSCSlotIdx,
|
|
olOSCLineIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "There input OSC signal cannot be framed."
|
|
::= { olOSCCondNotifications 0 3 }
|
|
|
|
|
|
olOSCLossOfFrameClear NOTIFICATION-TYPE
|
|
OBJECTS { olOSCCpTypeIdx,
|
|
olOSCShelfIdx,
|
|
olOSCSlotIdx,
|
|
olOSCLineIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active optical layer OSC Loss of Frame
|
|
condition has cleared."
|
|
::= { olOSCCondNotifications 0 4 }
|
|
|
|
|
|
olOSCLossOfLightTxCond NOTIFICATION-TYPE
|
|
OBJECTS { olOSCCpTypeIdx,
|
|
olOSCShelfIdx,
|
|
olOSCSlotIdx,
|
|
olOSCLineIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "There is no transmitted signal power detected for the
|
|
identified OSC."
|
|
::= { olOSCCondNotifications 0 5 }
|
|
|
|
|
|
olOSCLossOfLightTxClear NOTIFICATION-TYPE
|
|
OBJECTS { olOSCCpTypeIdx,
|
|
olOSCShelfIdx,
|
|
olOSCSlotIdx,
|
|
olOSCLineIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active optical layer OSC Transmit Loss of
|
|
Light condition has cleared."
|
|
::= { olOSCCondNotifications 0 6 }
|
|
|
|
|
|
olOSCFarEndIdMismatchCond NOTIFICATION-TYPE
|
|
OBJECTS { olOSCCpTypeIdx,
|
|
olOSCShelfIdx,
|
|
olOSCSlotIdx,
|
|
olOSCLineIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "The identifying attributes received for the far-end node
|
|
do not match the expected identifying attributes."
|
|
::= { olOSCCondNotifications 0 7 }
|
|
|
|
|
|
olOSCFarEndIdMismatchClear NOTIFICATION-TYPE
|
|
OBJECTS { olOSCCpTypeIdx,
|
|
olOSCShelfIdx,
|
|
olOSCSlotIdx,
|
|
olOSCLineIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active optical layer OSC Far End Identification
|
|
Mismatch condition has cleared."
|
|
::= { olOSCCondNotifications 0 8 }
|
|
|
|
|
|
olOSCFarEndNodeCnfgInconsistentCond NOTIFICATION-TYPE
|
|
OBJECTS { olOSCCpTypeIdx,
|
|
olOSCShelfIdx,
|
|
olOSCSlotIdx,
|
|
olOSCLineIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "The optical layer group configuration type for the far-end
|
|
node is inconsistent with the configuration type of
|
|
the local optical layer group."
|
|
::= { olOSCCondNotifications 0 9 }
|
|
|
|
|
|
olOSCFarEndNodeCnfgInconsistentClear NOTIFICATION-TYPE
|
|
OBJECTS { olOSCCpTypeIdx,
|
|
olOSCShelfIdx,
|
|
olOSCSlotIdx,
|
|
olOSCLineIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active optical layer OSC Far End Node
|
|
Configuration Inconsistent condition has cleared."
|
|
::= { olOSCCondNotifications 0 10 }
|
|
|
|
|
|
olOSCSpanContCommCond NOTIFICATION-TYPE
|
|
OBJECTS { olOSCCpTypeIdx,
|
|
olOSCShelfIdx,
|
|
olOSCSlotIdx,
|
|
olOSCLineIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "Bi-directional control communications with the node at the
|
|
opposite end of the span section have failed."
|
|
::= { olOSCCondNotifications 0 11 }
|
|
|
|
|
|
olOSCSpanContCommClear NOTIFICATION-TYPE
|
|
OBJECTS { olOSCCpTypeIdx,
|
|
olOSCShelfIdx,
|
|
olOSCSlotIdx,
|
|
olOSCLineIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active optical layer OSC Section Control
|
|
Communications condition has cleared."
|
|
::= { olOSCCondNotifications 0 12 }
|
|
|
|
|
|
olOSCEqlzContCommCond NOTIFICATION-TYPE
|
|
OBJECTS { olOSCCpTypeIdx,
|
|
olOSCShelfIdx,
|
|
olOSCSlotIdx,
|
|
olOSCLineIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "Bi-directional control communications with the node at the
|
|
opposite end of the equalization section have failed."
|
|
::= { olOSCCondNotifications 0 13 }
|
|
|
|
|
|
olOSCEqlzContCommClear NOTIFICATION-TYPE
|
|
OBJECTS { olOSCCpTypeIdx,
|
|
olOSCShelfIdx,
|
|
olOSCSlotIdx,
|
|
olOSCLineIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active optical layer OSC Equalization Control
|
|
Communications condition has cleared."
|
|
::= { olOSCCondNotifications 0 14 }
|
|
|
|
|
|
olOSCOpticalBackReflOutOfSpecCond NOTIFICATION-TYPE
|
|
OBJECTS { olOSCCpTypeIdx,
|
|
olOSCShelfIdx,
|
|
olOSCSlotIdx,
|
|
olOSCLineIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "The measured optical back reflection of the transmitted
|
|
OSC signal exceeds the specified maximum."
|
|
::= { olOSCCondNotifications 0 15 }
|
|
|
|
|
|
olOSCOpticalBackReflOutOfSpecClear NOTIFICATION-TYPE
|
|
OBJECTS { olOSCCpTypeIdx,
|
|
olOSCShelfIdx,
|
|
olOSCSlotIdx,
|
|
olOSCLineIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active optical layer OSC Optical Back
|
|
Reflection Out of Specification condition has cleared."
|
|
::= { olOSCCondNotifications 0 16 }
|
|
|
|
|
|
olOSCOpticalBackReflHighThCond NOTIFICATION-TYPE
|
|
OBJECTS { olOSCCpTypeIdx,
|
|
olOSCShelfIdx,
|
|
olOSCSlotIdx,
|
|
olOSCLineIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "The measured optical back reflection of the transmitted
|
|
OSC signal exceeds the high threshold."
|
|
::= { olOSCCondNotifications 0 17 }
|
|
|
|
|
|
olOSCOpticalBackReflHighThClear NOTIFICATION-TYPE
|
|
OBJECTS { olOSCCpTypeIdx,
|
|
olOSCShelfIdx,
|
|
olOSCSlotIdx,
|
|
olOSCLineIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active optical layer OSC Optical Back
|
|
Reflection High Threshold condition has cleared."
|
|
::= { olOSCCondNotifications 0 18 }
|
|
|
|
|
|
olPortPowerOutOfSpecRxCond NOTIFICATION-TYPE
|
|
OBJECTS { olPortCpTypeIdx,
|
|
olPortShelfIdx,
|
|
olPortSlotIdx,
|
|
olPortTypeIdx,
|
|
olPortIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "The power received on the optical port is outside the
|
|
operating range."
|
|
::= { olPortCondNotifications 0 1 }
|
|
|
|
|
|
olPortPowerOutOfSpecRxClear NOTIFICATION-TYPE
|
|
OBJECTS { olPortCpTypeIdx,
|
|
olPortShelfIdx,
|
|
olPortSlotIdx,
|
|
olPortTypeIdx,
|
|
olPortIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active optical layer port Received Power
|
|
Out Of Specification condition has cleared."
|
|
::= { olPortCondNotifications 0 2 }
|
|
|
|
|
|
olPortLossOfLightRxCond NOTIFICATION-TYPE
|
|
OBJECTS { olPortCpTypeIdx,
|
|
olPortShelfIdx,
|
|
olPortSlotIdx,
|
|
olPortTypeIdx,
|
|
olPortIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "There is no received optical power detected for the port."
|
|
::= { olPortCondNotifications 0 3 }
|
|
|
|
|
|
olPortLossOfLightRxClear NOTIFICATION-TYPE
|
|
OBJECTS { olPortCpTypeIdx,
|
|
olPortShelfIdx,
|
|
olPortSlotIdx,
|
|
olPortTypeIdx,
|
|
olPortIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active optical layer port Receive Loss of Light
|
|
condition has cleared."
|
|
::= { olPortCondNotifications 0 4 }
|
|
|
|
|
|
olPortLossRxOutOfSpecCond NOTIFICATION-TYPE
|
|
OBJECTS { olPortCpTypeIdx,
|
|
olPortShelfIdx,
|
|
olPortSlotIdx,
|
|
olPortTypeIdx,
|
|
olPortIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "The optical power loss measured over the span or
|
|
fiber connection terminating on the port in the
|
|
receive direction is outside the specification range."
|
|
::= { olPortCondNotifications 0 5 }
|
|
|
|
|
|
olPortLossRxOutOfSpecClear NOTIFICATION-TYPE
|
|
OBJECTS { olPortCpTypeIdx,
|
|
olPortShelfIdx,
|
|
olPortSlotIdx,
|
|
olPortTypeIdx,
|
|
olPortIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active optical layer port Receive Loss out of
|
|
Specification condition has cleared."
|
|
::= { olPortCondNotifications 0 6 }
|
|
|
|
|
|
olPortLossRxHighThCond NOTIFICATION-TYPE
|
|
OBJECTS { olPortCpTypeIdx,
|
|
olPortShelfIdx,
|
|
olPortSlotIdx,
|
|
olPortTypeIdx,
|
|
olPortIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "The optical power loss measured over the span terminating
|
|
on the line port in the receive direction is above
|
|
the high threshold level."
|
|
::= { olPortCondNotifications 0 7 }
|
|
|
|
|
|
olPortLossRxHighThClear NOTIFICATION-TYPE
|
|
OBJECTS { olPortCpTypeIdx,
|
|
olPortShelfIdx,
|
|
olPortSlotIdx,
|
|
olPortTypeIdx,
|
|
olPortIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active optical layer port Receive Loss
|
|
High Threshold condition has cleared."
|
|
::= { olPortCondNotifications 0 8 }
|
|
|
|
|
|
olPortAPSDCond NOTIFICATION-TYPE
|
|
OBJECTS { olPortCpTypeIdx,
|
|
olPortShelfIdx,
|
|
olPortSlotIdx,
|
|
olPortTypeIdx,
|
|
olPortIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "An automatic power shutdown has been automatically operated
|
|
on the optical layer port for safety reasons."
|
|
::= { olPortCondNotifications 0 9 }
|
|
|
|
|
|
olPortAPSDClear NOTIFICATION-TYPE
|
|
OBJECTS { olPortCpTypeIdx,
|
|
olPortShelfIdx,
|
|
olPortSlotIdx,
|
|
olPortTypeIdx,
|
|
olPortIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active optical layer port Automatic Power Shutdown
|
|
condition has cleared."
|
|
::= { olPortCondNotifications 0 10 }
|
|
|
|
|
|
olPortPayloadMissingIndCond NOTIFICATION-TYPE
|
|
OBJECTS { olPortCpTypeIdx,
|
|
olPortShelfIdx,
|
|
olPortSlotIdx,
|
|
olPortTypeIdx,
|
|
olPortIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A Payload Missing Indication has been received on the
|
|
optical layer port input."
|
|
::= { olPortCondNotifications 0 11 }
|
|
|
|
|
|
olPortPayloadMissingIndClear NOTIFICATION-TYPE
|
|
OBJECTS { olPortCpTypeIdx,
|
|
olPortShelfIdx,
|
|
olPortSlotIdx,
|
|
olPortTypeIdx,
|
|
olPortIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active optical layer port Payload Missing
|
|
Indication condition has cleared."
|
|
::= { olPortCondNotifications 0 12 }
|
|
|
|
|
|
olPortBackwardDefectIndCond NOTIFICATION-TYPE
|
|
OBJECTS { olPortCpTypeIdx,
|
|
olPortShelfIdx,
|
|
olPortSlotIdx,
|
|
olPortTypeIdx,
|
|
olPortIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A Backward Defect Indication has been received on the
|
|
optical layer port input."
|
|
::= { olPortCondNotifications 0 13 }
|
|
|
|
|
|
olPortBackwardDefectIndClear NOTIFICATION-TYPE
|
|
OBJECTS { olPortCpTypeIdx,
|
|
olPortShelfIdx,
|
|
olPortSlotIdx,
|
|
olPortTypeIdx,
|
|
olPortIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active optical layer port Backward Defect
|
|
Indication condition has cleared."
|
|
::= { olPortCondNotifications 0 14 }
|
|
|
|
|
|
olPortChannelCountDeficiencyCond NOTIFICATION-TYPE
|
|
OBJECTS { olPortCpTypeIdx,
|
|
olPortShelfIdx,
|
|
olPortSlotIdx,
|
|
olPortTypeIdx,
|
|
olPortIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A channel count deficiency condition has been raised against
|
|
the port. This indicates that the number of channels
|
|
received on the port is less than the number required to
|
|
maintain stable optical control given the high span loss
|
|
level detected on the receive span fiber."
|
|
::= { olPortCondNotifications 0 15 }
|
|
|
|
|
|
olPortChannelCountDeficiencyClear NOTIFICATION-TYPE
|
|
OBJECTS { olPortCpTypeIdx,
|
|
olPortShelfIdx,
|
|
olPortSlotIdx,
|
|
olPortTypeIdx,
|
|
olPortIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active optical layer port Channel Count
|
|
Deficiency condition has cleared."
|
|
::= { olPortCondNotifications 0 16 }
|
|
|
|
|
|
olPortConnectionMismatchCond NOTIFICATION-TYPE
|
|
OBJECTS { olPortCpTypeIdx,
|
|
olPortShelfIdx,
|
|
olPortSlotIdx,
|
|
olPortTypeIdx,
|
|
olPortIdx,
|
|
olPortExpCnxDegree,
|
|
olPortActCnxDegree,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "The identified optical layer port is incorrectly
|
|
connected and must be re-connected to a different
|
|
remote end port."
|
|
::= { olPortCondNotifications 0 17 }
|
|
|
|
|
|
olPortConnectionMismatchClear NOTIFICATION-TYPE
|
|
OBJECTS { olPortCpTypeIdx,
|
|
olPortShelfIdx,
|
|
olPortSlotIdx,
|
|
olPortTypeIdx,
|
|
olPortIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active optical layer port Connection
|
|
Mismatch condition has cleared."
|
|
::= { olPortCondNotifications 0 18 }
|
|
|
|
|
|
olPortConnectionValidationTimeoutCond NOTIFICATION-TYPE
|
|
OBJECTS { olPortCpTypeIdx,
|
|
olPortShelfIdx,
|
|
olPortSlotIdx,
|
|
olPortTypeIdx,
|
|
olPortIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "Connection validation could not be performed on the
|
|
identified optical layer port, which may mean that the
|
|
port is incorrectly connected."
|
|
::= { olPortCondNotifications 0 19 }
|
|
|
|
|
|
olPortConnectionValidationTimeoutClear NOTIFICATION-TYPE
|
|
OBJECTS { olPortCpTypeIdx,
|
|
olPortShelfIdx,
|
|
olPortSlotIdx,
|
|
olPortTypeIdx,
|
|
olPortIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active optical layer port Connection
|
|
Validation Timeout condition has cleared."
|
|
::= { olPortCondNotifications 0 20 }
|
|
|
|
|
|
wdmInvalidPreAmpOperCnfgCond NOTIFICATION-TYPE
|
|
OBJECTS { wdmCpTypeIdx,
|
|
wdmShelfIdx,
|
|
wdmSlotIdx,
|
|
wdmLineIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "The WDM optical pre-amplifier is operating at a configuration
|
|
which is invalid for the detected loss."
|
|
::= { wdmCondNotifications 0 1 }
|
|
|
|
|
|
wdmInvalidPreAmpOperCnfgClear NOTIFICATION-TYPE
|
|
OBJECTS { wdmCpTypeIdx,
|
|
wdmShelfIdx,
|
|
wdmSlotIdx,
|
|
wdmLineIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active WDM Invalid Pre-Amplifier Operating
|
|
Configuration condition has cleared."
|
|
::= { wdmCondNotifications 0 2 }
|
|
|
|
|
|
wdmInvalidMidAmpOperCnfgCond NOTIFICATION-TYPE
|
|
OBJECTS { wdmCpTypeIdx,
|
|
wdmShelfIdx,
|
|
wdmSlotIdx,
|
|
wdmLineIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "The WDM optical mid-amplifier is operating at a configuration
|
|
which is invalid for the detected loss."
|
|
::= { wdmCondNotifications 0 3 }
|
|
|
|
|
|
wdmInvalidMidAmpOperCnfgClear NOTIFICATION-TYPE
|
|
OBJECTS { wdmCpTypeIdx,
|
|
wdmShelfIdx,
|
|
wdmSlotIdx,
|
|
wdmLineIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active WDM Invalid Mid-Amplifier Operating
|
|
Configuration condition has cleared."
|
|
::= { wdmCondNotifications 0 4 }
|
|
|
|
|
|
wdmInvalidBoostAmpOperCnfgCond NOTIFICATION-TYPE
|
|
OBJECTS { wdmCpTypeIdx,
|
|
wdmShelfIdx,
|
|
wdmSlotIdx,
|
|
wdmLineIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "The WDM optical booster-amplifier is operating at a configuration
|
|
which is invalid for the detected loss."
|
|
::= { wdmCondNotifications 0 5 }
|
|
|
|
|
|
wdmInvalidBoostAmpOperCnfgClear NOTIFICATION-TYPE
|
|
OBJECTS { wdmCpTypeIdx,
|
|
wdmShelfIdx,
|
|
wdmSlotIdx,
|
|
wdmLineIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active WDM Invalid Booster-Amplifier Operating
|
|
Configuration condition has cleared."
|
|
::= { wdmCondNotifications 0 6 }
|
|
|
|
|
|
wchPowerOutOfSpecRxCond NOTIFICATION-TYPE
|
|
OBJECTS { wchCpTypeIdx,
|
|
wchShelfIdx,
|
|
wchSlotIdx,
|
|
wchPortTypeIdx,
|
|
wchPortIdx,
|
|
wchIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS deprecated
|
|
DESCRIPTION "The power received for the wavelength channel is outside the
|
|
operating range."
|
|
::= { wchCondNotifications 0 1 }
|
|
|
|
|
|
wchPowerOutOfSpecRxClear NOTIFICATION-TYPE
|
|
OBJECTS { wchCpTypeIdx,
|
|
wchShelfIdx,
|
|
wchSlotIdx,
|
|
wchPortTypeIdx,
|
|
wchPortIdx,
|
|
wchIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS deprecated
|
|
DESCRIPTION "A previously active Wavelength Channel Received Power Out Of
|
|
Specification condition has cleared."
|
|
::= { wchCondNotifications 0 2 }
|
|
|
|
|
|
wchLossOfLightRxCond NOTIFICATION-TYPE
|
|
OBJECTS { wchCpTypeIdx,
|
|
wchShelfIdx,
|
|
wchSlotIdx,
|
|
wchPortTypeIdx,
|
|
wchPortIdx,
|
|
wchIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "There is no received optical power detected for the channel."
|
|
::= { wchCondNotifications 0 3 }
|
|
|
|
|
|
wchLossOfLightRxClear NOTIFICATION-TYPE
|
|
OBJECTS { wchCpTypeIdx,
|
|
wchShelfIdx,
|
|
wchSlotIdx,
|
|
wchPortTypeIdx,
|
|
wchPortIdx,
|
|
wchIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active wavelength channel Receive Loss of Light condition
|
|
has cleared."
|
|
::= { wchCondNotifications 0 4 }
|
|
|
|
|
|
wchPowerOutOfSpecTxCond NOTIFICATION-TYPE
|
|
OBJECTS { wchCpTypeIdx,
|
|
wchShelfIdx,
|
|
wchSlotIdx,
|
|
wchPortTypeIdx,
|
|
wchPortIdx,
|
|
wchIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "The power transmitted for the wavelength channel is outside the
|
|
operating range."
|
|
::= { wchCondNotifications 0 5 }
|
|
|
|
|
|
wchPowerOutOfSpecTxClear NOTIFICATION-TYPE
|
|
OBJECTS { wchCpTypeIdx,
|
|
wchShelfIdx,
|
|
wchSlotIdx,
|
|
wchPortTypeIdx,
|
|
wchPortIdx,
|
|
wchIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active Wavelength Channel Transmitted Power Out Of
|
|
Specification condition has cleared."
|
|
::= { wchCondNotifications 0 6 }
|
|
|
|
|
|
wchLossOfLightTxCond NOTIFICATION-TYPE
|
|
OBJECTS { wchCpTypeIdx,
|
|
wchShelfIdx,
|
|
wchSlotIdx,
|
|
wchPortTypeIdx,
|
|
wchPortIdx,
|
|
wchIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "There is no transmitted optical power detected for the channel."
|
|
::= { wchCondNotifications 0 7 }
|
|
|
|
|
|
wchLossOfLightTxClear NOTIFICATION-TYPE
|
|
OBJECTS { wchCpTypeIdx,
|
|
wchShelfIdx,
|
|
wchSlotIdx,
|
|
wchPortTypeIdx,
|
|
wchPortIdx,
|
|
wchIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active wavelength channel Transmitted Loss of Light
|
|
condition has cleared."
|
|
::= { wchCondNotifications 0 8 }
|
|
|
|
|
|
wchUnequippedCond NOTIFICATION-TYPE
|
|
OBJECTS { wchCpTypeIdx,
|
|
wchShelfIdx,
|
|
wchSlotIdx,
|
|
wchPortTypeIdx,
|
|
wchPortIdx,
|
|
wchIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "An unequipped indication for the wavelength channel has been
|
|
received from the far-end node of the line span."
|
|
::= { wchCondNotifications 0 9 }
|
|
|
|
|
|
wchUnequippedClear NOTIFICATION-TYPE
|
|
OBJECTS { wchCpTypeIdx,
|
|
wchShelfIdx,
|
|
wchSlotIdx,
|
|
wchPortTypeIdx,
|
|
wchPortIdx,
|
|
wchIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active wavelength channel unequipped indication
|
|
condition has cleared."
|
|
::= { wchCondNotifications 0 10 }
|
|
|
|
|
|
wchAISCond NOTIFICATION-TYPE
|
|
OBJECTS { wchCpTypeIdx,
|
|
wchShelfIdx,
|
|
wchSlotIdx,
|
|
wchPortTypeIdx,
|
|
wchPortIdx,
|
|
wchIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "An alarm indication signal for the wavelength channel has been
|
|
received from the far-end node of the line span."
|
|
::= { wchCondNotifications 0 11 }
|
|
|
|
|
|
wchAISClear NOTIFICATION-TYPE
|
|
OBJECTS { wchCpTypeIdx,
|
|
wchShelfIdx,
|
|
wchSlotIdx,
|
|
wchPortTypeIdx,
|
|
wchPortIdx,
|
|
wchIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS current
|
|
DESCRIPTION "A previously active wavelength channel alarm indication signal
|
|
condition has cleared."
|
|
::= { wchCondNotifications 0 12 }
|
|
|
|
|
|
wchPowerOutOfSpecRxHighCond NOTIFICATION-TYPE
|
|
OBJECTS { wchCpTypeIdx,
|
|
wchShelfIdx,
|
|
wchSlotIdx,
|
|
wchPortTypeIdx,
|
|
wchPortIdx,
|
|
wchIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS deprecated
|
|
DESCRIPTION "The power received for the wavelength channel exceeds the
|
|
upper limit of the normal operating range."
|
|
::= { wchCondNotifications 0 13 }
|
|
|
|
|
|
wchPowerOutOfSpecRxHighClear NOTIFICATION-TYPE
|
|
OBJECTS { wchCpTypeIdx,
|
|
wchShelfIdx,
|
|
wchSlotIdx,
|
|
wchPortTypeIdx,
|
|
wchPortIdx,
|
|
wchIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS deprecated
|
|
DESCRIPTION "A previously active Wavelength Channel Received Power Out Of
|
|
Specification High condition has cleared."
|
|
::= { wchCondNotifications 0 14 }
|
|
|
|
|
|
wchPowerOutOfSpecRxLowCond NOTIFICATION-TYPE
|
|
OBJECTS { wchCpTypeIdx,
|
|
wchShelfIdx,
|
|
wchSlotIdx,
|
|
wchPortTypeIdx,
|
|
wchPortIdx,
|
|
wchIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS deprecated
|
|
DESCRIPTION "The power received for the wavelength channel is below the
|
|
lower limit of the normal operating range."
|
|
::= { wchCondNotifications 0 15 }
|
|
|
|
|
|
wchPowerOutOfSpecRxLowClear NOTIFICATION-TYPE
|
|
OBJECTS { wchCpTypeIdx,
|
|
wchShelfIdx,
|
|
wchSlotIdx,
|
|
wchPortTypeIdx,
|
|
wchPortIdx,
|
|
wchIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS deprecated
|
|
DESCRIPTION "A previously active Wavelength Channel Received Power Out Of
|
|
Specification Low condition has cleared."
|
|
::= { wchCondNotifications 0 16 }
|
|
|
|
|
|
wchPowerRxHighFailCond NOTIFICATION-TYPE
|
|
OBJECTS { wchCpTypeIdx,
|
|
wchShelfIdx,
|
|
wchSlotIdx,
|
|
wchPortTypeIdx,
|
|
wchPortIdx,
|
|
wchIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS deprecated
|
|
DESCRIPTION "The power received for the wavelength channel exceeds the
|
|
maximum allowable level. The wavelength channel is declared
|
|
to be failed at this power level."
|
|
::= { wchCondNotifications 0 17 }
|
|
|
|
|
|
wchPowerRxHighFailClear NOTIFICATION-TYPE
|
|
OBJECTS { wchCpTypeIdx,
|
|
wchShelfIdx,
|
|
wchSlotIdx,
|
|
wchPortTypeIdx,
|
|
wchPortIdx,
|
|
wchIdx,
|
|
condReportType,
|
|
condDateAndTime,
|
|
condSeverity,
|
|
condServiceAffecting,
|
|
trapSeqNum,
|
|
condDescription,
|
|
condObjectType,
|
|
condCodeType }
|
|
STATUS deprecated
|
|
DESCRIPTION "A previously active Wavelength Channel Received Power
|
|
High Fail condition has cleared."
|
|
::= { wchCondNotifications 0 18 }
|
|
|
|
|
|
|
|
END -- End of BTI-OL-MIB Module, must a /NL character at the end this line!
|
|
|