FOUNDRY-SN-STACKING-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32
FROM SNMPv2-SMI
snSwitch
FROM FOUNDRY-SN-SWITCH-GROUP-MIB
MacAddress
FROM SNMPv2-TC
DisplayString
FROM FOUNDRY-SN-AGENT-MIB
InterfaceIndexOrZero
FROM IF-MIB;
snStacking MODULE-IDENTITY
LAST-UPDATED "201809060000Z" -- Sept 6, 2018
ORGANIZATION "Ruckus Wireless, Inc."
CONTACT-INFO
"
Technical Support Center, Ruckus Wireless, Inc,
350 West Java Drive,
Sunnyvale, CA 94089, USA
Support URL: https://support.ruckuswireless.com
Phone: +1-855-782-5871
ROW TF Numbers: https://support.ruckuswireless.com/contact-us"
DESCRIPTION
"
Management Information for stacking system
configuration and operational status.
Copyright 1996-2017 Ruckus Wireless, Inc..
All rights reserved.
This Ruckus Wireless, Inc SNMP Management Information Base Specification
embodies Ruckus Wireless, Inc' confidential and proprietary
intellectual property. Ruckus Wireless, Inc retains all
title and ownership in the Specification, including any
revisions.
This Specification is supplied AS IS, and Ruckus Wireless, Inc makes
no warranty, either express or implied, as to the use,
operation, condition, or performance of the Specification.
"
REVISION "200805050000Z" -- May 5, 2008
DESCRIPTION
""
REVISION "201708070000Z" -- Aug 7, 2017
DESCRIPTION
"Modified contac Info, Organization and Decscription"
REVISION "201809060000Z" -- Sept 6, 2018
DESCRIPTION
"Added and deprecated some MIB objects based on Stacking enhancement features in FI8090"
::= { snSwitch 31}
--
-- Stacking system
--
snStackingGlobalObjects OBJECT IDENTIFIER ::= { snStacking 1 }
snStackingTableObjects OBJECT IDENTIFIER ::= { snStacking 2 }
--
-- Stacking system Global Scalar Object Section
--
snStackingGlobalConfigState OBJECT-TYPE
SYNTAX INTEGER {
none(0),
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure stack state for stacking feature on the global level.
none: neutral, receive packets only
enable: stacking is enable, send and receive packets
disable: stacking is disable, No send and receive packets"
::= { snStackingGlobalObjects 1}
snStackingGlobalMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Management MAC address of the stacking system.
This is available to change management MAC address of stack
for administrative purpose. It is strongly recommended that this
command should be used with upmost caution to prevent duplicate
MAC address and must reboot the system to take an effect.
It is mutually exclusive from enabling the persistent MAC timer.
Enter zero MAC address to remove the configured MAC address"
::= { snStackingGlobalObjects 2 }
snStackingGlobalPersistentMacTimerState OBJECT-TYPE
SYNTAX INTEGER {
enabled(0),
disabled(1)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Configure persistent MAC timer state for stacking feature on the global level.
enable: the persistent MAC timer is active and configured. The persistent MAC
timer is set as the default timer (60 minutes)
disable: deactivate the persistent MAC timer. It will stop the use of persistent MAC
address and use new active stack unit's base MAC address "
::= { snStackingGlobalObjects 3}
snStackingGlobalPersistentMacTimer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Persistent MAC timer in minutes for the stacking system
Number of minutes to retain original active stack unit's base MAC address in event of
active unit crash or removal. This timer is triggered when new active unit is elected.
When timer expires, new active unit will change stacking MAC to its own base MAC
address and advertise its own base MAC address to management VLAN to update the
ARP table of peers. If you decide to use new active unit's MAC address, one must enter
this timer again to reactivate the persistent MAC.
0 - keep it forever.
5 to 6000 - valid value range.
60 - default value."
::= { snStackingGlobalObjects 4 }
snStackingGlobalTopology OBJECT-TYPE
SYNTAX INTEGER {
other(1),
chain(2),
ring(3),
standalone(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The topology of the stacking system "
::= { snStackingGlobalObjects 5 }
snStackingGlobalMode OBJECT-TYPE
SYNTAX INTEGER {
stackingMode(1),
nonStackingMode(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The stacking mode of the system.
stackingMode: the system has been installed STK EEPROM, and it is in stacking mode.
nonStackingMode:the system has not been installed STK EEPROM, and it is not in stacking mode.
"
::= { snStackingGlobalObjects 6 }
snStackingGlobalMixedMode OBJECT-TYPE
SYNTAX INTEGER {
mixedStackingMode(1),
classicStackingMode(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mixed stacking mode of the system.
mixedStackingMode: the system is in a mixed stacking mode (heterogeneous stacking).
classicStackingMode: the system is not in a mixed stacking mode (homogeneous stacking).
"
::= { snStackingGlobalObjects 7 }
snStackingGlobalMaxUnitNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The max number of units in the stacking system. 1 as default value for no-stacking device"
::= { snStackingGlobalObjects 8 }
snStackingGlobalHighestPriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest stack priority that can be configured in the stacking system. 0 as default value
for no-stacking device"
::= { snStackingGlobalObjects 9 }
snStackingGlobalZeroTouchEnable OBJECT-TYPE
SYNTAX INTEGER {
none(0),
enabled (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure Stack Zero Touch feature for a stacking system on the global level.
The Zero Touch feature discovers new stack member units, assigns them IDs,
defines stack-port/trunk, and allows member unit to join the stacking system.
none: neutral state, receive packets only
enabled: Stack Zero touch feature is enabled
The none state will be displayed if stacking is not enabled.
The default state is none"
::= { snStackingGlobalObjects 10}
--
-- Stacking system Table Object Section
--
--
-- Stacking configuration unit Table
-- Use this table to display and configure stacking related information for each unit
--
snStackingConfigUnitTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnStackingConfigUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Stacking configuration unit table."
::= { snStackingTableObjects 1 }
snStackingConfigUnitEntry OBJECT-TYPE
SYNTAX SnStackingConfigUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the stacking configuration table."
INDEX { snStackingConfigUnitIndex }
::= { snStackingConfigUnitTable 1 }
SnStackingConfigUnitEntry ::= SEQUENCE {
snStackingConfigUnitIndex Integer32,
snStackingConfigUnitPriority Integer32,
snStackingConfigUnitConfigStackPort InterfaceIndexOrZero,
snStackingConfigUnitRowStatus INTEGER,
snStackingConfigUnitType DisplayString,
snStackingConfigUnitState INTEGER,
snStackingConfigUnitStackPort1 InterfaceIndexOrZero,
snStackingConfigUnitStackPort2 InterfaceIndexOrZero,
snStackingConfigUnitConnectPort1 InterfaceIndexOrZero,
snStackingConfigUnitConnectPort2 InterfaceIndexOrZero,
snStackingConfigUnitStackTrunk1 OCTET STRING,
snStackingConfigUnitStackTrunk2 OCTET STRING,
snStackingConfigUnitName DisplayString
}
snStackingConfigUnitIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The stacking unit Id"
::= { snStackingConfigUnitEntry 1 }
snStackingConfigUnitPriority OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The priority in Active/backup eclection."
::= { snStackingConfigUnitEntry 2 }
snStackingConfigUnitConfigStackPort OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"The IfIndex for the configured stacking port. If no
stacking port is configured, it will be displayed zero
and the first two 10G ports as the default stacking ports.
Enter zero to remove the configured stacking port.
Note that this object is deprecated from FI8090 because
the default ports are no longer supported. Use snStackingConfigUnitStackPort1
or snStackingConfigUnitStackPort2 for stack ports. Thus, the value of this
object is one of stack port or zero for backup capability."
::= { snStackingConfigUnitEntry 3 }
snStackingConfigUnitRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3)
-- create(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to delete row in the
table and control if they are used. The values that
can be written are:
delete(3)...deletes the row
If the row exists, then a SET with value of create(4)
returns error 'wrongValue'. Deleted rows go away immediately.
The following values can be returned on reads:
noSuchName...no such row
other(1).....some other cases
valid(2)....the row exists and is valid"
::= { snStackingConfigUnitEntry 4 }
snStackingConfigUnitType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A description of the configured/active system type for each unit."
::= { snStackingConfigUnitEntry 5 }
snStackingConfigUnitState OBJECT-TYPE
SYNTAX INTEGER {
local(1),
remote(2),
reserved(3),
empty(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A state for each unit "
::= { snStackingConfigUnitEntry 6 }
snStackingConfigUnitStackPort1 OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A stack port for the unit. It returns 0 if stack port does not exist.
Entering 0 means to delete this stack port.
Note that the maximum stack port on an unit is 2."
::= { snStackingConfigUnitEntry 7 }
snStackingConfigUnitStackPort2 OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Other one stack port for the unit. It returns 0 if stack port does not exist.
Entering 0 means to delete this stack port.
Note that the maximum stack port on an unit is 2."
::= { snStackingConfigUnitEntry 8 }
snStackingConfigUnitConnectPort1 OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"First connect port for a peripheral unit in a mixed stacking system. A peripheral
unit can have up to two connect ports that is is conected to. They are suggested
neighbor linking ports. Thus, they could be code units' periport/trunk or peripheral
units' stacking port. It returns 0 if connect port does not exist.
Note that this object is deprecated from FI8090."
::= { snStackingConfigUnitEntry 9 }
snStackingConfigUnitConnectPort2 OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"second connect port for a peripheral unit in a mixed stacking system. A peripheral
unit can have up to two connect ports that is is conected to. They are suggested
neighbor linking ports. Thus, they could be code units' periport/trunk or peripheral
units' stacking port. It returns 0 if connect port does not exist.
Note that this object is deprecated from FI8090."
::= { snStackingConfigUnitEntry 10 }
snStackingConfigUnitStackTrunk1 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A list of interface indices which are the port membership
of a stack trunk on unit. Each interface index is a 32-bit integer
in big endian order. It returns NULL if stack trunk does not exist.
Entering empty octet string means to delete this stack trunk.
Note that the maximum stack trunk on an unit is 2. Each stack trunk
contains up to 16 ports."
::= { snStackingConfigUnitEntry 11 }
snStackingConfigUnitStackTrunk2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A list of interface indices which are the port membership
of a stack trunk on unit. Each interface index is a 32-bit integer
in big endian order. It returns NULL if stack trunk does not exist.
Entering empty octet string means to delete this stack trunk.
Note that the maximum stack trunk on an unit is 2. Each stack trunk
contains up to 16 ports."
::= { snStackingConfigUnitEntry 12 }
snStackingConfigUnitName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A name description of stacking unit."
::= { snStackingConfigUnitEntry 13 }
--
-- Stacking operation unit Table
-- Use this table to display stacking related information for each operational unit
--
snStackingOperUnitTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnStackingOperUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Stacking operation unit table."
::= { snStackingTableObjects 2 }
snStackingOperUnitEntry OBJECT-TYPE
SYNTAX SnStackingOperUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the stacking operation table."
INDEX { snStackingOperUnitIndex }
::= { snStackingOperUnitTable 1 }
SnStackingOperUnitEntry ::= SEQUENCE {
snStackingOperUnitIndex Integer32,
snStackingOperUnitRole INTEGER,
snStackingOperUnitMac MacAddress,
snStackingOperUnitPriority Integer32,
snStackingOperUnitState INTEGER,
snStackingOperUnitDescription DisplayString,
snStackingOperUnitStackPort1 InterfaceIndexOrZero,
snStackingOperUnitStackPort1State INTEGER,
snStackingOperUnitStackPort2 InterfaceIndexOrZero,
snStackingOperUnitStackPort2State INTEGER,
snStackingOperUnitNeighbor1 Integer32,
snStackingOperUnitNeighbor2 Integer32,
snStackingOperUnitImgVer DisplayString,
snStackingOperUnitBuildlVer DisplayString
}
snStackingOperUnitIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The stacking unit Id"
::= { snStackingOperUnitEntry 1 }
snStackingOperUnitRole OBJECT-TYPE
SYNTAX INTEGER {
other(1),
active(2),
standby(3),
member(4),
standalone(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A role for each unit "
::= { snStackingOperUnitEntry 2 }
snStackingOperUnitMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A MAC address for each unit"
::= { snStackingOperUnitEntry 3 }
snStackingOperUnitPriority OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The priority in Active/backup eclection."
::= { snStackingOperUnitEntry 4 }
snStackingOperUnitState OBJECT-TYPE
SYNTAX INTEGER {
local(1),
remote(2),
reserved(3),
empty(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A state for each unit "
::= { snStackingOperUnitEntry 5}
snStackingOperUnitDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describes the stacking state for each unit."
::= { snStackingOperUnitEntry 6 }
snStackingOperUnitStackPort1 OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"First stack port for each unit. It returns 0 if stack port does not exist."
::= { snStackingOperUnitEntry 7 }
snStackingOperUnitStackPort1State OBJECT-TYPE
SYNTAX INTEGER {
other(1),
up(2),
down(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The first stack port state for each unit. "
::= { snStackingOperUnitEntry 8 }
snStackingOperUnitStackPort2 OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Second stack port for each unit. It returns 0 if stack port does not exist."
::= { snStackingOperUnitEntry 9 }
snStackingOperUnitStackPort2State OBJECT-TYPE
SYNTAX INTEGER {
other(1),
up(2),
down(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The second stack port state for each unit. "
::= { snStackingOperUnitEntry 10 }
snStackingOperUnitNeighbor1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Stacking neighbor unit (left) number.
If there is no neighbor unit, then it returns 0."
::= { snStackingOperUnitEntry 11 }
snStackingOperUnitNeighbor2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Stacking neighbor unit (right) number.
If there is no neighbor unit, then it returns 0."
::= { snStackingOperUnitEntry 12 }
snStackingOperUnitImgVer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version of the running software image"
::= { snStackingOperUnitEntry 13 }
snStackingOperUnitBuildlVer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version of the running software build"
::= { snStackingOperUnitEntry 14 }
--
-- Stacking configuration stack trunk Table
-- Use this table to display and configure stack trunks for each unit
-- Note: this table is deprecated from FI8090. Use snStackingConfigUnitStackTrunk1 and
-- snStackingConfigUnitStackTrunk2 for stack trunks.
--
snStackingConfigStackTrunkTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnStackingConfigStackTrunkEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Stacking configuration stack trunk table."
::= { snStackingTableObjects 3 }
snStackingConfigStackTrunkEntry OBJECT-TYPE
SYNTAX SnStackingConfigStackTrunkEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"An entry in the stacking configuration Stack trunk table."
INDEX { snStackingConfigStackTrunkUnit, snStackingConfigStackTrunkPort1,
snStackingConfigStackTrunkPort2 }
::= { snStackingConfigStackTrunkTable 1 }
SnStackingConfigStackTrunkEntry ::= SEQUENCE {
snStackingConfigStackTrunkUnit Integer32,
snStackingConfigStackTrunkPort1 InterfaceIndexOrZero,
snStackingConfigStackTrunkPort2 InterfaceIndexOrZero,
snStackingConfigStackTrunkRowStatus INTEGER,
snStackingConfigStackTrunkNumPort1 Integer32,
snStackingConfigStackTrunkNumPort2 Integer32
}
snStackingConfigStackTrunkUnit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"The stacking unit Id"
::= { snStackingConfigStackTrunkEntry 1 }
snStackingConfigStackTrunkPort1 OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"The IfIndex for the first (primary) port of the configured stack trunk.
There are two ports per stack trunk. In some case, a physical port may contain
more than one port, e.g. one 40G (1/2/2) for ICX6610 has 4x10G ports.
It returns 0 if the port does not exist."
::= { snStackingConfigStackTrunkEntry 2 }
snStackingConfigStackTrunkPort2 OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"The IfIndex for the second port of the configured stack trunk.
There are two ports per stack trunk. In some case, a physical port may contain
more than one logical port, e.g. one 40G (1/2/2) for ICX6610 has 4x10G ports.
It returns 0 if the port does not exist."
::= { snStackingConfigStackTrunkEntry 3 }
snStackingConfigStackTrunkRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object is used to delete row in the
table and control if they are used. The values that
can be written are:
delete(3)...deletes the row
If the row exists, then a SET with value of create(4)
returns error 'wrongValue'. Deleted rows go away immediately.
The following values can be returned on reads:
noSuchName...no such row
other(1).....some other cases
valid(2)....the row exists and is valid"
::= { snStackingConfigStackTrunkEntry 4 }
snStackingConfigStackTrunkNumPort1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
" Number of logical ports for the first (primary) port of the configured stack trunk.
In some case, a physical port may contain more than one logical port,
e.g. one 40G (1/2/2) for ICX6610 has 4x10G ports. It returns 0 if the port
does not exist."
::= { snStackingConfigStackTrunkEntry 5 }
snStackingConfigStackTrunkNumPort2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
" Number of logical ports for the second port of the configured stack trunk.
In some case, a physical port may contain more than one logical port,
e.g. one 40G (1/2/2) for ICX6610 has 4x10G ports. It returns 0 if the port
does not exist."
::= { snStackingConfigStackTrunkEntry 6 }
--
-- Stacking configuration peripheral port Table
-- Use this table to display and configure mixed stacking peripheral ports for each unit
-- Note: this table is deprecated from FI8090.
--
snStackingConfigPeriPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnStackingConfigPeriPortEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Stacking configuration peripheral port table."
::= { snStackingTableObjects 4 }
snStackingConfigPeriPortEntry OBJECT-TYPE
SYNTAX SnStackingConfigPeriPortEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"An entry in the stacking configuration peripheral port table."
INDEX { snStackingConfigPeriPortUnit, snStackingConfigPeriPortPort }
::= { snStackingConfigPeriPortTable 1 }
SnStackingConfigPeriPortEntry ::= SEQUENCE {
snStackingConfigPeriPortUnit Integer32,
snStackingConfigPeriPortPort InterfaceIndexOrZero,
snStackingConfigPeriPortRowStatus INTEGER
}
snStackingConfigPeriPortUnit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"The stacking unit Id"
::= { snStackingConfigPeriPortEntry 1 }
snStackingConfigPeriPortPort OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"The IfIndex for the configured mixed stacking peripheral port.
It is up to eight peripheral ports per unit. "
::= { snStackingConfigPeriPortEntry 2 }
snStackingConfigPeriPortRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object is used to delete row in the
table and control if they are used. The values that
can be written are:
delete(3)...deletes the row
If the row exists, then a SET with value of create(4)
returns error 'wrongValue'. Deleted rows go away immediately.
The following values can be returned on reads:
noSuchName...no such row
other(1).....some other cases
valid(2)....the row exists and is valid"
::= { snStackingConfigPeriPortEntry 3 }
--
-- Stacking configuration peripheral trunk Table
-- Use this table to display and configure mixed stacking peripheral trunks for each unit
-- Note: this table is deprecated from FI8090.
--
snStackingConfigPeriTrunkTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnStackingConfigPeriTrunkEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Stacking configuration peripheral trunk table."
::= { snStackingTableObjects 5 }
snStackingConfigPeriTrunkEntry OBJECT-TYPE
SYNTAX SnStackingConfigPeriTrunkEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"An entry in the stacking configuration peripheral trunk table."
INDEX { snStackingConfigPeriTrunkUnit, snStackingConfigPeriTrunkPort1,
snStackingConfigPeriTrunkPort2 }
::= { snStackingConfigPeriTrunkTable 1 }
SnStackingConfigPeriTrunkEntry ::= SEQUENCE {
snStackingConfigPeriTrunkUnit Integer32,
snStackingConfigPeriTrunkPort1 InterfaceIndexOrZero,
snStackingConfigPeriTrunkPort2 InterfaceIndexOrZero,
snStackingConfigPeriTrunkRowStatus INTEGER
}
snStackingConfigPeriTrunkUnit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"The stacking unit Id"
::= { snStackingConfigPeriTrunkEntry 1 }
snStackingConfigPeriTrunkPort1 OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"The IfIndex for the first port of the configured mixed stacking peripheral trunk.
There are two ports per peripheral trunk. It is up to four peripheral trunks per unit."
::= { snStackingConfigPeriTrunkEntry 2 }
snStackingConfigPeriTrunkPort2 OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"The IfIndex for the second port of the configured mixed stacking peripheral trunk.
There are two ports per peripheral trunk. It is up to four peripheral trunks per unit."
::= { snStackingConfigPeriTrunkEntry 3 }
snStackingConfigPeriTrunkRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to delete row in the
table and control if they are used. The values that
can be written are:
delete(3)...deletes the row
If the row exists, then a SET with value of create(4)
returns error 'wrongValue'. Deleted rows go away immediately.
The following values can be returned on reads:
noSuchName...no such row
other(1).....some other cases
valid(2)....the row exists and is valid"
::= { snStackingConfigPeriTrunkEntry 4 }
--
-- Stacking neighbor port Table
-- Use this table to display stacking neighbor ports for each unit
--
snStackingNeighborPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnStackingNeighborPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Stacking neighbor port table."
::= { snStackingTableObjects 6 }
snStackingNeighborPortEntry OBJECT-TYPE
SYNTAX SnStackingNeighborPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the stacking neighborport table."
INDEX { snStackingNeighborPortUnit, snStackingNeighborPortStackPort }
::= { snStackingNeighborPortTable 1 }
SnStackingNeighborPortEntry ::= SEQUENCE {
snStackingNeighborPortUnit Integer32,
snStackingNeighborPortStackPort InterfaceIndexOrZero,
snStackingNeighborPortNeighborPort InterfaceIndexOrZero
}
snStackingNeighborPortUnit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The stacking unit Id"
::= { snStackingNeighborPortEntry 1 }
snStackingNeighborPortStackPort OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The IfIndex for the stack port on this unit.
if it is a stack trunk, then this port is the first port
of stack trunk."
::= { snStackingNeighborPortEntry 2 }
snStackingNeighborPortNeighborPort OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IfIndex for the neighbor port of the stack port on this unit.
if it is a stack trunk, then this port is the first port of stack
trunk on the neighbor unit.
It returns 0 if neighbor port does not exist for this stack port. "
::= { snStackingNeighborPortEntry 3 }
END