-- Title: Fibre Channel Switch MIB.
|
|
--
|
|
|
|
FA-EXT-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
DisplayString, TEXTUAL-CONVENTION, TruthValue
|
|
FROM SNMPv2-TC
|
|
Integer32, OBJECT-TYPE, OBJECT-IDENTITY,
|
|
MODULE-IDENTITY
|
|
FROM SNMPv2-SMI
|
|
sw
|
|
FROM SW-MIB
|
|
connUnitPortEntry
|
|
FROM FCMGMT-MIB;
|
|
|
|
faExt MODULE-IDENTITY
|
|
LAST-UPDATED "201310291354Z" -- Oct 29, 2013 01:54pm
|
|
ORGANIZATION "Brocade Communications Systems, Inc.,"
|
|
CONTACT-INFO "Customer Support Group
|
|
Brocade Communications Systems,
|
|
1745 Technology Drive,
|
|
San Jose, CA 95110 U.S.A
|
|
Tel: +1-408-392-6061
|
|
Fax: +1-408-392-6656
|
|
Email: support@Brocade.COM
|
|
WEB: www.brocade.com"
|
|
|
|
|
|
DESCRIPTION "The MIB module is Extension for FA-MIB.
|
|
Copyright (c) 1996-2003 Brocade Communications Systems, Inc.
|
|
All rights reserved."
|
|
REVISION "201011221030Z" -- Nov 22, 2010 10:30am
|
|
DESCRIPTION "Initial version of this module."
|
|
REVISION "201309121030Z" -- Sep 12, 2013 10:00am
|
|
DESCRIPTION "Added swConnUnitPortFECMode"
|
|
REVISION "201309241355Z" -- Sep 24, 2013 01:55pm
|
|
DESCRIPTION "Added swConnUnitPortFECState"
|
|
REVISION "201310291354Z" -- Oct 29, 2013 01:54pm
|
|
DESCRIPTION "Added notsupported value for swConnUnitPortFECState"
|
|
::= { sw 28 }
|
|
|
|
swSfpStatTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwSfpStatEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This represents the diagnostic stats of SFPs."
|
|
::= { faExt 1 }
|
|
|
|
swFapwwnFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The OID sub-tree for Fapwwn feature. Using this feature
|
|
user can configure virtual port WWN for a port."
|
|
::= { faExt 2 }
|
|
|
|
swPortConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwPortConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This represents the configuration of
|
|
encryption / compression feature on a port"
|
|
::= { faExt 3 }
|
|
|
|
swConnUnitPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwConnUnitPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This represents the Conn unit Port entry"
|
|
::= { faExt 4 }
|
|
|
|
swSfpStatEntry OBJECT-TYPE
|
|
SYNTAX SwSfpStatEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This represents the diagnostic stats of SFPs"
|
|
AUGMENTS {connUnitPortEntry}
|
|
::= { swSfpStatTable 1 }
|
|
|
|
SwSfpStatEntry ::= SEQUENCE {
|
|
swSfpTemperature OCTET STRING,
|
|
swSfpVoltage OCTET STRING,
|
|
swSfpCurrent OCTET STRING,
|
|
swSfpRxPower OCTET STRING,
|
|
swSfpTxPower OCTET STRING,
|
|
swSfpPoweronHrs Integer32,
|
|
swSfpUnitId Integer32
|
|
}
|
|
|
|
swSfpTemperature OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(8))
|
|
UNITS "centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the temperature of SFP"
|
|
::= { swSfpStatEntry 1 }
|
|
|
|
swSfpVoltage OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(8))
|
|
UNITS "milli voltage"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the voltage of SFP."
|
|
::= { swSfpStatEntry 2 }
|
|
|
|
swSfpCurrent OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(8))
|
|
UNITS "milli amphere"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the current of SFP."
|
|
::= { swSfpStatEntry 3 }
|
|
|
|
swSfpRxPower OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(8))
|
|
UNITS "dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the Rx power consumption of SFP."
|
|
::= { swSfpStatEntry 4 }
|
|
|
|
swSfpTxPower OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(8))
|
|
UNITS "dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the Tx power consumption of SFP."
|
|
::= { swSfpStatEntry 5 }
|
|
|
|
swSfpPoweronHrs OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "hours"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the power on hours of SFP.
|
|
This is applicable only to 16G SFPs."
|
|
::= { swSfpStatEntry 6 }
|
|
|
|
swSfpUnitId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies unit ID of SFP.
|
|
This is applicable only to QSFP."
|
|
::= { swSfpStatEntry 7 }
|
|
|
|
swPortFapwwnConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwPortFapwwnConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This represents the configuration of ports."
|
|
::= { swFapwwnFeature 1 }
|
|
|
|
swPortFapwwnConfigEntry OBJECT-TYPE
|
|
SYNTAX SwPortFapwwnConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This represents the configuration of ports."
|
|
AUGMENTS {connUnitPortEntry}
|
|
::= { swPortFapwwnConfigTable 1 }
|
|
|
|
FapwwnType ::= INTEGER {
|
|
unknown(1),
|
|
auto(2),
|
|
userConfigured(3)
|
|
}
|
|
|
|
SwPortFapwwnConfigEntry ::= SEQUENCE {
|
|
swPortFapwwnConfigEnable TruthValue,
|
|
swPortFapwwnConfigFapwwn DisplayString,
|
|
swPortFapwwnConfigType FapwwnType
|
|
}
|
|
|
|
swPortFapwwnConfigEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Represents the Fapwwn status. This is for per port."
|
|
::= { swPortFapwwnConfigEntry 1 }
|
|
|
|
swPortFapwwnConfigFapwwn OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(256))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Represents the Fapwwn. For AG it is range of WWNs.
|
|
If Fapwwn feature is not enabled in a port this
|
|
object value is NA(Not Applicable."
|
|
::= { swPortFapwwnConfigEntry 2 }
|
|
|
|
swPortFapwwnConfigType OBJECT-TYPE
|
|
SYNTAX FapwwnType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Represents the Fapwwn type. "
|
|
::= { swPortFapwwnConfigEntry 3 }
|
|
|
|
swPortConfigEntry OBJECT-TYPE
|
|
SYNTAX SwPortConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This represents the configuration of
|
|
encryption / compression feature on a port"
|
|
AUGMENTS {connUnitPortEntry}
|
|
::= { swPortConfigTable 1 }
|
|
|
|
|
|
CiperMode ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Represents cipher mode."
|
|
SYNTAX INTEGER {
|
|
none (1),
|
|
allFrames (2),
|
|
fcpAndNonFCP (3),--FCP data frames and non
|
|
--FCP frames except ELS (R_CTL=0x2)
|
|
--and BLS frames (R_CTL=0x8)
|
|
onlyFCP (4)
|
|
}
|
|
|
|
EncryptCompressStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Represents status of feature encryption or compression."
|
|
SYNTAX INTEGER {
|
|
enabled (1),
|
|
disabled (2),
|
|
unknown (3)
|
|
}
|
|
|
|
SwPortConfigEntry ::= SEQUENCE {
|
|
swPortEncrypt EncryptCompressStatus,
|
|
swPortCompression EncryptCompressStatus,
|
|
swPortCipherKeySize Integer32,
|
|
swPortCipherMode CiperMode
|
|
}
|
|
swPortEncrypt OBJECT-TYPE
|
|
SYNTAX EncryptCompressStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Represents the encryption status on a port."
|
|
::= { swPortConfigEntry 1 }
|
|
|
|
|
|
swPortCompression OBJECT-TYPE
|
|
SYNTAX EncryptCompressStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Represents the compression status on port."
|
|
::= { swPortConfigEntry 2 }
|
|
|
|
|
|
swPortCipherKeySize OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Represents the Cipher key size.
|
|
FOS supports 256 bytes key"
|
|
::= { swPortConfigEntry 3 }
|
|
|
|
|
|
swPortCipherMode OBJECT-TYPE
|
|
SYNTAX CiperMode
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Represents the Cipher mode. "
|
|
::= { swPortConfigEntry 4 }
|
|
|
|
swConnUnitPortEntry OBJECT-TYPE
|
|
SYNTAX SwConnUnitPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This represents the Conn unit Port Entry"
|
|
AUGMENTS {connUnitPortEntry}
|
|
::= { swConnUnitPortTable 1 }
|
|
|
|
SwConnUnitPortEntry ::= SEQUENCE {
|
|
swConnUnitPortCapableSpeeds OCTET STRING,
|
|
swConnUnitPortSpeedMode INTEGER,
|
|
swConnUnitPortFECMode INTEGER,
|
|
swConnUnitPortFECState INTEGER
|
|
}
|
|
|
|
swConnUnitPortCapableSpeeds OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This represents the available speeds, that a port is capable of configuring"
|
|
::= { swConnUnitPortEntry 1 }
|
|
|
|
swConnUnitPortSpeedMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
auto-neg (1),
|
|
static (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This represents the type of speed modes that can be configured for the particular port.
|
|
The modes that can be configured are auto-negotiable and static speeds."
|
|
::= { swConnUnitPortEntry 2 }
|
|
|
|
swConnUnitPortFECMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
disabled (2),
|
|
enabled (3),
|
|
notsupported (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This represents the port Forward Error Correction Mode. FEC feature is only applicable to 10G/16G platforms."
|
|
::= { swConnUnitPortEntry 3 }
|
|
|
|
swConnUnitPortFECState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (0),
|
|
active (1),
|
|
inactive (2),
|
|
notsupported (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This represents FEC state of a port.If in link both sfp connected are of brocade vendor type
|
|
then state is active, else it will be inactive."
|
|
::= { swConnUnitPortEntry 4 }
|
|
END
|