299 lines
10 KiB
Plaintext

BD-MIB DEFINITIONS ::= BEGIN
IMPORTS
DisplayString, TEXTUAL-CONVENTION, TruthValue
FROM SNMPv2-TC
OBJECT-TYPE, OBJECT-IDENTITY,
MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
SwPortIndex
FROM Brocade-TC
fcSwitch, bcsiModules
FROM Brocade-REG-MIB
swVfId
FROM SW-MIB;
bd MODULE-IDENTITY
LAST-UPDATED "201404101146Z" -- Apr 10, 2014 11:46am
ORGANIZATION "Brocade Communications Systems, Inc.,"
CONTACT-INFO "Customer Support Group
Brocade Communications Systems,
1745 Technology Drive,
San Jose, CA 95110 U.S.A
Tel: +1-408-392-6061
Fax: +1-408-392-6656
Email: support@Brocade.COM
WEB: www.brocade.com"
DESCRIPTION "The MIB module is for Brocade's Bottleneck detection feature.Copyright (c) 1996-2003 Brocade Communications Systems, Inc. All rights reserved."
REVISION "201404101146Z" -- Apr 10, 2014 11:46am
DESCRIPTION "Added slotPort object in bdStatsEntry and included it
in bdTrap and bdClearTrap."
::= { fcSwitch 51 }
BdType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "BD type"
SYNTAX INTEGER {
congestion (1),
latency (2)
}
bdTraps OBJECT-IDENTITY
STATUS current
DESCRIPTION "The OID represents the BD Traps."
::= { bd 0 }
bdConfig OBJECT-IDENTITY
STATUS current
DESCRIPTION "The OID represents the BD config."
::= { bd 1 }
bdStats OBJECT-IDENTITY
STATUS current
DESCRIPTION "This OID represents the BD stats."
::= { bd 2 }
bdStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object gives the status of bottleneck detection feature
if enabled in the switch. The value of this OID if true(1) or false(2)."
::= { bdConfig 1 }
bdLThreshold OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..5))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object is the severity threshold for latency bottleneck.
This threshold indicates the percentage of one-second intervals
affected by latency conditions within a specified time window.
The value of this OID is between 0 and 1."
::= { bdConfig 2 }
bdCThreshold OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..5))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object is the severity threshold for congestion bottleneck.
This threshold indicates the percentage of one-second intervals
affected by congestion conditions within a specified time window.
The value of this OID is between 0 and 1"
::= { bdConfig 3 }
bdQTime OBJECT-TYPE
SYNTAX INTEGER(1..1000)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum number of seconds between consecutive alerts.
The value assigned to this parameter applies to both latency and
congestion monitoring. In this duration, there will not be
any traps sent."
::= { bdConfig 4 }
bdWinAvgTime OBJECT-TYPE
SYNTAX INTEGER (1..100)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The time window in seconds over which the percentage of seconds
affected by bottleneck conditions is computed and compared
with the threshold."
::= { bdConfig 5 }
bdThreshold OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..5))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "This is the severity threshold for latency or congestion
bottleneck. This is accessible only for traps. This object is
one of the variable binding in bdTrap and bdClearTrap."
::= { bdConfig 6 }
nBdType OBJECT-TYPE
SYNTAX BdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "This is the type of bottleneck.This is accessible only for
traps. This object is one of the variable binding in bdTrap and
bdClearTrap. This can have a value of congestion(1) or latency(2)."
::= { bdConfig 7 }
bdNumOfEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of rows in the stats table."
::= { bdStats 1 }
bdStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF BdStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The table of stats entries represents both types of bottleneck.
Each sample in the stats is taken every 10 seconds.The maximum
number of entries for each port, each type
[congestion/latency] is 30."
::= { bdStats 2 }
bdStatsEntry OBJECT-TYPE
SYNTAX BdStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry of BD stats information."
INDEX { userPortNumber, bdType, bdSampleTime}
::= { bdStatsTable 1 }
BdStatsEntry ::= SEQUENCE {
userPortNumber SwPortIndex,
bdSampleTime Unsigned32,
bdType BdType,
bdStatsValue10SecsSample DisplayString,
bdStatsValue60SecsSample DisplayString,
bdStatsValue300SecsSample DisplayString,
slotPort DisplayString
}
userPortNumber OBJECT-TYPE
SYNTAX SwPortIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object represents the user port indices of bottleneck
monitored ports like F-port, E-port, L-port, FCOE-port."
::= { bdStatsEntry 1 }
bdSampleTime OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object represents the sample time in Unix time format.
Ex:1265259069 The above Unix time is equal to
Thu, 04 Feb 2010 04:51:09 GMT ."
::= { bdStatsEntry 2 }
bdType OBJECT-TYPE
SYNTAX BdType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object represents the bottleneck type. The value of
this object can be congestion(1) or latency(2)."
::= { bdStatsEntry 3 }
bdStatsValue10SecsSample OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..5))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This sample is average of 10 samples collected every second.
If the sample has not been taken yet then bdStatsValue10SecsSample
return -1."
::= { bdStatsEntry 4 }
bdStatsValue60SecsSample OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..5))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This sample is average of 60 samples collected every second.
If the sample has not been taken yet then bdStatsValue60SecsSample
return -1."
::= { bdStatsEntry 5 }
bdStatsValue300SecsSample OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..5))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This sample is average of 300 samples collected every second.
If the sample has not been taken yet then bdStatsValue300SecsSample
return -1."
::= { bdStatsEntry 6 }
slotPort OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "This object represents the slot/port format of userPortNumber for bottleneck
monitored ports like F-port, E-port, L-port, FCOE-port."
::= { bdStatsEntry 7 }
bdAggrStats OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..12))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "This object represents the aggregrate stats value.
This value is the sum of all the samples divided by average
window and multiplied by 100.This is accessible only for traps.
This obejct is one of the variable binding in bdTrap and
bdClearTrap."
::= { bdStats 3 }
bdAbsoluteValue OBJECT-TYPE
SYNTAX INTEGER (1..1000)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "This object represents the absolute value of bdAggrStats.
It is the number of affected seconds. This object is accessible
only for traps and it is one of the variable binding in
bdTrap and bdClearTrap."
::= { bdStats 4 }
bdAvgFrameSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "This object represents the average size in bytes of all frames
that were transmitted on the ports during the averaging window.
This object is accessible only for traps and it is one of the
variable binding in bdTrap and bdClearTrap."
::= { bdStats 5 }
bdTrap NOTIFICATION-TYPE
OBJECTS {
userPortNumber,
slotPort,
bdWinAvgTime,
nBdType,
bdThreshold,
bdAggrStats,
bdAbsoluteValue,
swVfId,
bdAvgFrameSize
}
STATUS current
DESCRIPTION "trap to be send for bottleneck detection."
::= { bdTraps 1 }
bdClearTrap NOTIFICATION-TYPE
OBJECTS {
userPortNumber,
slotPort,
bdWinAvgTime,
nBdType,
bdThreshold,
bdAggrStats,
bdAbsoluteValue,
swVfId,
bdAvgFrameSize
}
STATUS current
DESCRIPTION "trap to be send for bottleneck clearance."
::= { bdTraps 2 }