-- This SMIv2 module has been generated by smidump 0.4.1. Do not edit.
--
BRWAVE-RADIO-MIB DEFINITIONS ::= BEGIN
IMPORTS
ifIndex
FROM IF-MIB
OBJECT-GROUP
FROM SNMPv2-CONF
Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY,
OBJECT-TYPE, Unsigned32, enterprises
FROM SNMPv2-SMI
DisplayString
FROM SNMPv2-TC;
brwaveRadioMibModule MODULE-IDENTITY
LAST-UPDATED "200607061100Z"
ORGANIZATION
"BridgeWave Communications"
CONTACT-INFO
"
Postal: BridgeWave Communications
3350 Thomas Road
Santa Clara, CA 95054
USA
Tel: +1 408 567 6900
Fax: +1 408 567 0775
Web: www.bridgewave.com
"
DESCRIPTION
"Radio MIB module."
REVISION "200607061100Z"
DESCRIPTION
"Combined ROOT/RADIO mib in one module."
REVISION "200505261130Z"
DESCRIPTION
"Radio MIB module created."
::= { brwaveMibs 3 }
bridgeWave OBJECT-IDENTITY
STATUS current
DESCRIPTION
"BridgeWave enterprise OID."
::= { enterprises 6080 }
brwaveReg OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-tree for BridgeWave objects registration."
::= { bridgeWave 1 }
brwaveMibs OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-tree to register values assigned to MIB modules
with the MODULES-IDENTITY construct."
::= { brwaveReg 1 }
brwaveModules OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-tree to register unique values assigned to
identify all BridgeWave hardware and software
components of ethernet radio products."
::= { brwaveReg 2 }
brwaveRadioFE60 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Registered System OID for FE60 radio."
::= { brwaveModules 1 }
brwaveRadioGE60 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Registered System OID for GE60 radio."
::= { brwaveModules 2 }
brwaveRadioAR60 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Registered system OID for AdaptiveRate(AR60) radio."
::= { brwaveModules 3 }
brwaveCommon OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-tree for BridgeWave objects common across products."
::= { bridgeWave 2 }
brwaveRadioSn OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Radio serial number."
::= { brwaveCommon 1 }
brwaveUnitModel OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unit's model."
::= { brwaveCommon 2 }
brwaveBbSn OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Base Band hardware serial number"
::= { brwaveCommon 3 }
brwaveIfSn OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IF hardware serial number"
::= { brwaveCommon 4 }
brwaveMmwSn OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MMW Hardware serial number"
::= { brwaveCommon 5 }
brwaveTrapCount OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of traps generated by unit since start-up.
Rolls back to zero once reached to maximum value."
::= { brwaveCommon 6 }
brwaveProducts OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-tree for product specific objects & events"
::= { bridgeWave 3 }
brwaveRadio OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Ethernet Radio (FE60/GE60/AR60) obejcts."
::= { brwaveProducts 1 }
brwaveRadioFactorySetup OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Group of factory setup objects."
::= { brwaveRadio 2 }
brwaveRadioTxBand OBJECT-TYPE
SYNTAX INTEGER { low(1), high(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Radio Link Transmit frequency."
::= { brwaveRadioFactorySetup 1 }
brwaveRadioFactoryRate OBJECT-TYPE
SYNTAX INTEGER { adaptRate(1), mbps1000(2), mbps100(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Factory configured radio link rate."
::= { brwaveRadioFactorySetup 3 }
brwaveRadioClearStats OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clear Statistics, Set value of 1 to clear.
Returns always 0 when read."
::= { brwaveRadioFactorySetup 4 }
brwaveRadioStatus OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Group of radio status objects."
::= { brwaveRadio 3 }
brwaveRadioInVoltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Input voltage. The reading of the unit's input voltage
level in Volts x100."
::= { brwaveRadioStatus 1 }
brwaveRadioUnitTemperature OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unit Temperature. The reading of the temperature sensor
in degrees C x 100."
::= { brwaveRadioStatus 2 }
brwaveRadioTxTemperature OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Radio Transmiter Temperature. The reading of the radio
temperature sensor in degrees C x 100."
::= { brwaveRadioStatus 3 }
brwaveRadioRSL OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received Signal Level. The signal level of the received
radio frequency in dBm x 100"
::= { brwaveRadioStatus 4 }
brwaveRadioRSLVoltage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received Signal Level measured as Voltage."
::= { brwaveRadioStatus 5 }
brwaveRadioAbsRSL OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received Signal Level. The signal level of the received
radio frequency in dBm x 100"
::= { brwaveRadioStatus 6 }
brwaveRadioRSLVoltageInt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received Signal Level measured as Voltage."
::= { brwaveRadioStatus 7 }
brwaveCopperUtilization OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link utilization calculated every polling interval."
::= { brwaveRadioStatus 8 }
brwaveFiberUtilization OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link utilization calculated every polling interval."
::= { brwaveRadioStatus 9 }
brwaveRadioUtilization OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link utilization calculated every polling interval."
::= { brwaveRadioStatus 10 }
brwaveRadioFecError OBJECT-TYPE
SYNTAX INTEGER { noError(0), preFec(1), postFec(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Post and Pre FEC error calculated every polling interval
0 - No Error, 1-Pre FEC Error, 2-Post FEC Error"
::= { brwaveRadioStatus 11 }
brwaveRadioPreFecFlag OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pre FEC error flag every polling interval"
::= { brwaveRadioStatus 12 }
brwaveRadioPostFecFlag OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Post FEC error Flag every polling interval"
::= { brwaveRadioStatus 13 }
brwaveRadioLinkRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Radio Link Rate in Mbps."
::= { brwaveRadioStatus 14 }
brwaveRadioEvents OBJECT IDENTIFIER
::= { brwaveRadio 9 }
brwaveRadioEventsV2 OBJECT IDENTIFIER
::= { brwaveRadioEvents 0 }
brwaveRadioTrapObjs OBJECT IDENTIFIER
::= { brwaveRadioEvents 1 }
managerIP OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..32))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"IP address of NMS station accessing the unit."
::= { brwaveRadioTrapObjs 1 }
userName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..32))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"User accessing the unit."
::= { brwaveRadioTrapObjs 2 }
brwaveConformance OBJECT IDENTIFIER
::= { brwaveRadio 10 }
brwaveRadioGroups OBJECT IDENTIFIER
::= { brwaveConformance 1 }
brwaveCompliances OBJECT IDENTIFIER
::= { brwaveConformance 2 }
brwaveErrorsOverThreshold NOTIFICATION-TYPE
OBJECTS { ifIndex, brwaveRadioUnitTemperature,
brwaveRadioTxTemperature, brwaveRadioRSL }
STATUS current
DESCRIPTION
"Link has error rate over threshold."
::= { brwaveRadioEventsV2 1 }
brwaveErrorsUnderThreshold NOTIFICATION-TYPE
OBJECTS { ifIndex, brwaveRadioUnitTemperature,
brwaveRadioTxTemperature, brwaveRadioRSL }
STATUS current
DESCRIPTION
"Link error rate changed from over to under threshold ."
::= { brwaveRadioEventsV2 2 }
brwaveUnitTemperatureAbnormal NOTIFICATION-TYPE
OBJECTS { brwaveRadioUnitTemperature }
STATUS current
DESCRIPTION
"Radio unit temperature not in normal operating range.
Normal range is: -20 to +75 degree Centigrade."
::= { brwaveRadioEventsV2 3 }
brwaveUnitTemperatureNormal NOTIFICATION-TYPE
OBJECTS { brwaveRadioUnitTemperature }
STATUS current
DESCRIPTION
"Unit temperature restores from abnormal to normal range."
::= { brwaveRadioEventsV2 4 }
brwaveTxTemperatureAbnormal NOTIFICATION-TYPE
OBJECTS { brwaveRadioTxTemperature }
STATUS current
DESCRIPTION
"Transmitter temperature is not in normal operating range.
Normal range is: -20 to +75 degree Centigrade."
::= { brwaveRadioEventsV2 5 }
brwaveTxTemperatureNormal NOTIFICATION-TYPE
OBJECTS { brwaveRadioTxTemperature }
STATUS current
DESCRIPTION
"Transmitter temperature is restored to normal range."
::= { brwaveRadioEventsV2 6 }
brwaveInputVoltageAbnormal NOTIFICATION-TYPE
OBJECTS { brwaveRadioInVoltage }
STATUS current
DESCRIPTION
"Unit's input voltage is not in normal range.
Normal input voltage > 16 Volts."
::= { brwaveRadioEventsV2 7 }
brwaveInputVoltageNormal NOTIFICATION-TYPE
OBJECTS { brwaveRadioInVoltage }
STATUS current
DESCRIPTION
"Unit's input voltage is restored to normal range."
::= { brwaveRadioEventsV2 8 }
brwaveRslNormal NOTIFICATION-TYPE
OBJECTS { brwaveRadioRSL }
STATUS current
DESCRIPTION
"Received Signal Level is normal. Normal signal level
RSL > -55.00 dBm (Gigabit) and RSL > -59.00 dBm (Fast Ethernet)."
::= { brwaveRadioEventsV2 10 }
brwaveRslMinor NOTIFICATION-TYPE
OBJECTS { brwaveRadioRSL }
STATUS current
DESCRIPTION
"Received Signal Leve droped to the level of minor event.
RSL from -55.00 to -59.00 dBm (GE Radio)
RSL from -59.00 to -65.00 dBm (FE radio)."
::= { brwaveRadioEventsV2 11 }
brwaveRslMajor NOTIFICATION-TYPE
OBJECTS { brwaveRadioRSL }
STATUS current
DESCRIPTION
"RSL droppped to the level of major event.
RSL < -59.00 dBm (GE Radio) or RSL < -65 dBm (FE radio)."
::= { brwaveRadioEventsV2 13 }
brwaveConfigChange NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Configuration changes are performed by WEB client."
::= { brwaveRadioEventsV2 26 }
brwaveLoginSuccessfull NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"NMS Loged in successfully."
::= { brwaveRadioEventsV2 27 }
brwaveGeToFeSwitch NOTIFICATION-TYPE
OBJECTS { brwaveRadioRSL }
STATUS current
DESCRIPTION
"Tx Rate switched from GE to FE."
::= { brwaveRadioEventsV2 28 }
brwaveFeToGeSwitch NOTIFICATION-TYPE
OBJECTS { brwaveRadioRSL }
STATUS current
DESCRIPTION
"Tx Rate switched from FE to GE."
::= { brwaveRadioEventsV2 29 }
brwaveCommonGroup OBJECT-GROUP
OBJECTS { brwaveRadioSn, brwaveUnitModel, brwaveTrapCount }
STATUS current
DESCRIPTION
"Collection of common objects."
::= { brwaveRadioGroups 1 }
brwaveFactoryGroup OBJECT-GROUP
OBJECTS { brwaveRadioTxBand }
STATUS current
DESCRIPTION
"Collection of factory setup objects."
::= { brwaveRadioGroups 2 }
brwaveStatusGroup OBJECT-GROUP
OBJECTS { brwaveRadioInVoltage, brwaveRadioUnitTemperature,
brwaveRadioTxTemperature, brwaveRadioRSL,
brwaveRadioRSLVoltage }
STATUS current
DESCRIPTION
"Collection of status objects."
::= { brwaveRadioGroups 3 }
END -- end of module BRWAVE-RADIO-MIB.