Observium_CE/mibs/bintec/FEC-SYSINY-MIB

179 lines
5.0 KiB
Plaintext

-- This file is corresponding to Release 9.1.10.101 from 2014/08/11 00:00:00
---------------------------------------------------------------------------
-- (C)opyright 2007-2014 bintec elmeg GmbH
-- $RCSfile: mib-sysiny,v $
-- $Revision: 1.6 $
-- $Date: 2014-02-07 10:37:50 $
---------------------------------------------------------------------------
FEC-SYSINY-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Unsigned32,
mib-2, enterprises
FROM SNMPv2-SMI
DisplayString, TimeStamp, TruthValue
FROM SNMPv2-TC
Date
FROM BINTEC-MIB
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
sys
FROM BINTEC-MIB;
---------------------------------------------------------------------------
sysINYMIB MODULE-IDENTITY
LAST-UPDATED "200704261756Z"
ORGANIZATION "bintec elmeg GmbH"
CONTACT-INFO
"EMail: info@bintec-elmeg.com
Web: www.bintec-elmeg.com
"
DESCRIPTION
"The MIB module for INY specific parts.
"
REVISION "200705021519Z"
DESCRIPTION
"INY specific MIB."
::= { sys 5 }
---------------------------------------------------------------------------
-- OID groups & all tables
---------------------------------------------------------------------------
sysInyRelais OBJECT IDENTIFIER ::= { sysINYMIB 1 }
-- sysInyRelaisState 1
sysInyTemperature OBJECT IDENTIFIER ::= { sysINYMIB 2 }
-- sysInyTemperatureCurrent 1
-- sysInyTemperatureMax 2
-- sysInyTemperatureMaxTime 3
-- sysInyTemperatureMin 4
-- sysInyTemperatureMinTime 5
-- sysInyTemperatureUpdatePeriod 6
-- sysInyTemperatureLowerThreshold 7
-- sysInyTemperatureUpperThreshold 8
-- sysInyTemperatureAlarm 9
---------------------------------------------------------------------------
---------------------------------------------------------------------------
-- sysInyRelais
---------------------------------------------------------------------------
sysInyRelaisState OBJECT-TYPE
SYNTAX INTEGER { off(1), on(2), alarm(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Relais control.
off : Relais control coil is always off.
on : Relais control coil is always on.
alarm : Relais control coil controlled by failure LED."
DEFVAL { off }
::= { sysInyRelais 1 }
---------------------------------------------------------------------------
---------------------------------------------------------------------------
-- sysInyTemperature
---------------------------------------------------------------------------
sysInyTemperatureCurrent OBJECT-TYPE
SYNTAX INTEGER (-55..125)
UNITS "degree Centigrade"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature during the last measurement time."
::= { sysInyTemperature 1 }
sysInyTemperatureMax OBJECT-TYPE
SYNTAX INTEGER (-55..125)
UNITS "degree Centigrade"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum observed temperature."
::= { sysInyTemperature 2 }
sysInyTemperatureMaxTime OBJECT-TYPE
SYNTAX Date
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Point in time the maximum temperature was observed."
::= { sysInyTemperature 3 }
sysInyTemperatureMin OBJECT-TYPE
SYNTAX INTEGER (-55..125)
UNITS "degree Centigrade"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum observed temperature."
::= { sysInyTemperature 4 }
sysInyTemperatureMinTime OBJECT-TYPE
SYNTAX Date
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Point in time the minimum temperature was observed."
::= { sysInyTemperature 5 }
sysInyTemperatureUpdatePeriod OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Measurement interval of temperature update in seconds.
0: Disable measurements."
DEFVAL { 10 }
::= { sysInyTemperature 6 }
sysInyTemperatureLowerThreshold OBJECT-TYPE
SYNTAX INTEGER (-55..125)
UNITS "degree Centigrade"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minimal allowed temperature. If temperature falls below
this threshold, a syslog message is generated."
DEFVAL { -25 }
::= { sysInyTemperature 7 }
sysInyTemperatureUpperThreshold OBJECT-TYPE
SYNTAX INTEGER (-55..125)
UNITS "degree Centigrade"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximal allowed temperature. If temperature raises above
this threshold, a syslog message is generated."
DEFVAL { 70 }
::= { sysInyTemperature 8 }
sysInyTemperatureAlarm OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if the defined temperature thresholds are
violated."
DEFVAL { false }
::= { sysInyTemperature 9 }
---------------------------------------------------------------------------
END