-- This file is corresponding to Release 9.1.10.101 from 2014/08/11 00:00:00
|
|
|
|
|
|
---------------------------------------------------------------------------
|
|
-- (C)opyright 2007-2014 bintec elmeg GmbH
|
|
-- $RCSfile: mib-sysiny,v $
|
|
-- $Revision: 1.6 $
|
|
-- $Date: 2014-02-07 10:37:50 $
|
|
---------------------------------------------------------------------------
|
|
|
|
FEC-SYSINY-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
|
|
Unsigned32,
|
|
mib-2, enterprises
|
|
FROM SNMPv2-SMI
|
|
|
|
DisplayString, TimeStamp, TruthValue
|
|
FROM SNMPv2-TC
|
|
|
|
Date
|
|
FROM BINTEC-MIB
|
|
|
|
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
|
|
sys
|
|
FROM BINTEC-MIB;
|
|
|
|
---------------------------------------------------------------------------
|
|
|
|
sysINYMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200704261756Z"
|
|
ORGANIZATION "bintec elmeg GmbH"
|
|
CONTACT-INFO
|
|
"EMail: info@bintec-elmeg.com
|
|
Web: www.bintec-elmeg.com
|
|
"
|
|
DESCRIPTION
|
|
"The MIB module for INY specific parts.
|
|
"
|
|
REVISION "200705021519Z"
|
|
DESCRIPTION
|
|
"INY specific MIB."
|
|
|
|
::= { sys 5 }
|
|
|
|
---------------------------------------------------------------------------
|
|
-- OID groups & all tables
|
|
---------------------------------------------------------------------------
|
|
sysInyRelais OBJECT IDENTIFIER ::= { sysINYMIB 1 }
|
|
-- sysInyRelaisState 1
|
|
|
|
sysInyTemperature OBJECT IDENTIFIER ::= { sysINYMIB 2 }
|
|
-- sysInyTemperatureCurrent 1
|
|
-- sysInyTemperatureMax 2
|
|
-- sysInyTemperatureMaxTime 3
|
|
-- sysInyTemperatureMin 4
|
|
-- sysInyTemperatureMinTime 5
|
|
-- sysInyTemperatureUpdatePeriod 6
|
|
-- sysInyTemperatureLowerThreshold 7
|
|
-- sysInyTemperatureUpperThreshold 8
|
|
-- sysInyTemperatureAlarm 9
|
|
|
|
|
|
---------------------------------------------------------------------------
|
|
|
|
---------------------------------------------------------------------------
|
|
-- sysInyRelais
|
|
---------------------------------------------------------------------------
|
|
|
|
sysInyRelaisState OBJECT-TYPE
|
|
SYNTAX INTEGER { off(1), on(2), alarm(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Relais control.
|
|
off : Relais control coil is always off.
|
|
on : Relais control coil is always on.
|
|
alarm : Relais control coil controlled by failure LED."
|
|
DEFVAL { off }
|
|
::= { sysInyRelais 1 }
|
|
|
|
---------------------------------------------------------------------------
|
|
|
|
---------------------------------------------------------------------------
|
|
-- sysInyTemperature
|
|
---------------------------------------------------------------------------
|
|
|
|
sysInyTemperatureCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER (-55..125)
|
|
UNITS "degree Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Temperature during the last measurement time."
|
|
::= { sysInyTemperature 1 }
|
|
|
|
sysInyTemperatureMax OBJECT-TYPE
|
|
SYNTAX INTEGER (-55..125)
|
|
UNITS "degree Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum observed temperature."
|
|
::= { sysInyTemperature 2 }
|
|
|
|
sysInyTemperatureMaxTime OBJECT-TYPE
|
|
SYNTAX Date
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Point in time the maximum temperature was observed."
|
|
::= { sysInyTemperature 3 }
|
|
|
|
sysInyTemperatureMin OBJECT-TYPE
|
|
SYNTAX INTEGER (-55..125)
|
|
UNITS "degree Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum observed temperature."
|
|
::= { sysInyTemperature 4 }
|
|
|
|
sysInyTemperatureMinTime OBJECT-TYPE
|
|
SYNTAX Date
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Point in time the minimum temperature was observed."
|
|
::= { sysInyTemperature 5 }
|
|
|
|
sysInyTemperatureUpdatePeriod OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Measurement interval of temperature update in seconds.
|
|
0: Disable measurements."
|
|
DEFVAL { 10 }
|
|
::= { sysInyTemperature 6 }
|
|
|
|
sysInyTemperatureLowerThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (-55..125)
|
|
UNITS "degree Centigrade"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimal allowed temperature. If temperature falls below
|
|
this threshold, a syslog message is generated."
|
|
DEFVAL { -25 }
|
|
::= { sysInyTemperature 7 }
|
|
|
|
sysInyTemperatureUpperThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (-55..125)
|
|
UNITS "degree Centigrade"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximal allowed temperature. If temperature raises above
|
|
this threshold, a syslog message is generated."
|
|
DEFVAL { 70 }
|
|
::= { sysInyTemperature 8 }
|
|
|
|
sysInyTemperatureAlarm OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the defined temperature thresholds are
|
|
violated."
|
|
DEFVAL { false }
|
|
::= { sysInyTemperature 9 }
|
|
|
|
---------------------------------------------------------------------------
|
|
END
|