-- CADANT-REMOTE-QUERY-MIB: Cadant C4 Remote Query MIB file
--
-- August 2004
--
-- Copyright (c) 2004 by ARRIS International
-- All rights reserved.
-- *****************************************************************
CADANT-REMOTE-QUERY-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
Integer32,
IpAddress,
Unsigned32
FROM SNMPv2-SMI
TruthValue,
TimeStamp,
DisplayString,
MacAddress
FROM SNMPv2-TC
InetAddressType,
InetAddress
FROM INET-ADDRESS-MIB
OBJECT-GROUP,
MODULE-COMPLIANCE
FROM SNMPv2-CONF
TenthdBmV,
TenthdB
FROM DOCS-IF-MIB
cadCmRemoteQuery
FROM CADANT-PRODUCTS-MIB
cadIfCmtsCmStatusEntry
FROM CADANT-CMTS-MAC-MIB;
cadCmRemoteQueryMib MODULE-IDENTITY
LAST-UPDATED "200901200000Z"
ORGANIZATION "Arris International"
CONTACT-INFO
" Arris Support
Postal: ARRIS
Phone: +1 770 622 8530
E-mail: support@arrisi.com"
DESCRIPTION
"This MIB module provides the management of
the Cadant C4 Cable Modem Termination Systems
(CMTS) Remote Query feature.
This feature, implemented on a CMTS, facilitates
SNMP polling of remote cable modems (CMs).
This MIB includes the configuration and
status objects of the CMTS CM Poller and
remote CMs that polled by the CMTS CM Poller"
REVISION "200408310000Z"
DESCRIPTION
"Initial version of this MIB. "
REVISION "200609270000Z"
DESCRIPTION
"Added IPaddressType and IPaddress. "
REVISION "200901150000Z"
DESCRIPTION
"Fixed start/stop time for upTime rollover. "
REVISION "200901200000Z"
DESCRIPTION
"Fixed poll time for upTime rollover. "
::= { cadCmRemoteQuery 1}
--
-- Poller Group
--
-- Allows to configure and monitor the CMTS CM Poller
--
-- CMTS CM Poller
--
cadCmRemoteQueryPoller OBJECT IDENTIFIER ::= { cadCmRemoteQueryMib 1 }
cadCmRemoteQueryPollerEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An indication of whether the CMTS CM Poller is running.
When the poller is enabled, it polls the remote CMs
periodically specified in the cadCmRemoteQueryPollerInterval
mib object.
The operation can be expensive depending on how many CMs
that the poller would be polling. It is suggested to
have it disabled when not needed."
DEFVAL { false }
::= { cadCmRemoteQueryPoller 1 }
cadCmRemoteQueryPollerInterval OBJECT-TYPE
SYNTAX Unsigned32(30..86400)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An interval between two polling cycles of the CMTS CM
Poller.
The poller will not start the next cycle until it
finished polling for the last CM , even though the
time has expired. If the cadCmRemoteQueryPollerInterval is
too small with a large number of CMs, the poller would
tie up the CPU and resources and possibly degrade the
system's performance."
DEFVAL { 1800 }
::= { cadCmRemoteQueryPoller 2 }
cadCmRemoteQueryPollerStartTime OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime in seconds when the last polling
cycle started.
cadCmRemoteQueryPollerStartTime is set to 0 when the CMTS
is first restarted and doesn't get reset after the
poller is disabled."
::= { cadCmRemoteQueryPoller 3 }
cadCmRemoteQueryPollerStopTime OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime in seconds when the last polling
cycle finished.
cadCmRemoteQueryPollerStopTime is set to 0 when the CMTS
is first restarted and doesn't get reset after the poller
is disabled."
::= { cadCmRemoteQueryPoller 4 }
cadCmRemoteQueryPollerCommunity OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The read community string is used for polling the CMs.
Any change in the cadCmRemoteQueryPollerCommunity may not
be reflected if the poller has already been enabled."
DEFVAL { "public" }
::= { cadCmRemoteQueryPoller 5 }
cadCmRemoteQueryMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object is used to trigger an immediate poll of a
specific CM. This object always read back as a value
of 0. The value of sysUpTime should be read and saved
before writing this object. Then, the value of
cadCmRemoteQueryPollTime can be read and compared to the
saved sysUpTime to determine when the immediate poll of
retmoe query data has been completed."
DEFVAL { '000000000000'h }
::= { cadCmRemoteQueryPoller 6 }
cadCmRemoteQuerySourceIpAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of internet address of cadCmRemoteQuerySourceIpAddr."
DEFVAL { ipv4 }
::= { cadCmRemoteQueryPoller 7 }
cadCmRemoteQuerySourceIpAddr OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The source IP address of the SNMP remote queries to the CMs.
This value is changed from the Poller when the ifIndex of the
cadSysSourceInterfaceRemoteQuery in the CADANT-CMTS-SYSTEM-MIB
is changed due to using the cli command ..
configure cable modem remote-query source-interface .."
DEFVAL { '00000000'h }
::= { cadCmRemoteQueryPoller 8 }
--
-- CM Group
--
-- Allows to monitor the status of CM
--
--
-- CMTS Remote Cable modem (CM) Table
--
--
cadCmRemoteQueryStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadCmRemoteQueryStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the status of the cable modems that
are polled by the CMTS CM Poller. The information will be
overwritten when a new polling cycle starts.
Depending on how many CMs that the poller is polling,
polling this table constantly can be quite expensive;
Excessive polling could degrade performance."
::= { cadCmRemoteQueryMib 2 }
cadCmRemoteQueryStatusEntry OBJECT-TYPE
SYNTAX CadCmRemoteQueryStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of the cable modem's attributes
that are polled by a CMTS. "
AUGMENTS { cadIfCmtsCmStatusEntry }
::= { cadCmRemoteQueryStatusTable 1 }
CadCmRemoteQueryStatusEntry ::= SEQUENCE {
cadCmRemoteQueryPollTime Unsigned32,
cadCmRemoteQueryDownChannelPower TenthdBmV,
cadCmRemoteQueryStatusTxPower TenthdBmV,
cadCmRemoteQueryUpChnlTxTimingOffset Unsigned32,
cadCmRemoteQuerySigQSignalNoise TenthdB,
cadCmRemoteQuerySigQMicroreflections Integer32,
cadCmRemoteQuerySysDescr DisplayString
}
cadCmRemoteQueryPollTime OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this CM entry was polled.
If this value is larger than the cadCmRemoteQueryPollerStopTime,
it indicates that the status has already been
overwritten by a new polling cycle. To avoid this
happening, the NMS can increase the cadCmRemoteQueryPollInterval
so that the cadCmRemoteQueryPollTime
would fall in between the cadCmRemoteQueryPollerStartTime and
the cadCmRemoteQueryPollerStopTime."
::= { cadCmRemoteQueryStatusEntry 1 }
cadCmRemoteQueryDownChannelPower OBJECT-TYPE
SYNTAX TenthdBmV
UNITS "dBmV"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The CM's received power level. This object
may be set to zero if the CM does not support
power level measurement.
If the CM downstream interface is down, this object
either returns the most current value or the value of 0."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Table 4-12 and Table 4-13."
::={ cadCmRemoteQueryStatusEntry 2 }
cadCmRemoteQueryStatusTxPower OBJECT-TYPE
SYNTAX TenthdBmV
UNITS "dBmV"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational transmit power for the CM upstream
channel."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 4.2.8."
::= { cadCmRemoteQueryStatusEntry 3 }
cadCmRemoteQueryUpChnlTxTimingOffset OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A measure of the current round trip time. Used for
timing of CM upstream transmissions to ensure
synchronized arrivals at the CMTS."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Section 6.5."
::= { cadCmRemoteQueryStatusEntry 4 }
cadCmRemoteQuerySigQSignalNoise OBJECT-TYPE
SYNTAX TenthdB
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal/Noise ratio as perceived for the CM downstream
channel."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Table 2-1 and 2-2"
::= { cadCmRemoteQueryStatusEntry 5 }
cadCmRemoteQuerySigQMicroreflections OBJECT-TYPE
SYNTAX Integer32 (0..255)
UNITS "dBc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total microreflections including in-channel
response as perceived on the CM downstream,
measured in dBc below the signal level.
This object is not assumed to return an absolutely
accurate value, but is meant to give a rough indication
of microreflections received on this interface.
It is up to the implementor to provide information
as accurate as possible."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Table 2-1 and 2-2"
::= { cadCmRemoteQueryStatusEntry 6 }
cadCmRemoteQuerySysDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual description of the entity."
::= { cadCmRemoteQueryStatusEntry 7 }
--
-- The Remote Query MIB Conformance Statements
--
--
-- Conformance statement
--
cadCmRemoteQueryConformance OBJECT IDENTIFIER
::= { cadCmRemoteQueryMib 3 }
cadCmRemoteQueryDocsRemoteQueryCompliances OBJECT IDENTIFIER
::= { cadCmRemoteQueryConformance 1 }
cadCmRemoteQueryDocsRemoteQueryGroups OBJECT IDENTIFIER
::= { cadCmRemoteQueryConformance 2 }
-- compliance statements
cadCmRemoteQueryDocsRemoteQueryCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities which
implement the Remote Query MIB"
MODULE -- this module
MANDATORY-GROUPS {
cadCmRemoteQueryPollerGroup,
cadCmRemoteQueryStatusGroup
}
::= { cadCmRemoteQueryDocsRemoteQueryCompliances 1 }
-- MIB groupings
cadCmRemoteQueryPollerGroup OBJECT-GROUP
OBJECTS {
cadCmRemoteQueryPollerEnable,
cadCmRemoteQueryPollerInterval,
cadCmRemoteQueryPollerStartTime,
cadCmRemoteQueryPollerStopTime,
cadCmRemoteQueryPollerCommunity
}
STATUS current
DESCRIPTION
"Group of objects implemented in Cable Modem
Termination Systems (CMTS) for configuring and
monitoring the CMTS CM Poller."
::= { cadCmRemoteQueryDocsRemoteQueryGroups 1 }
cadCmRemoteQueryStatusGroup OBJECT-GROUP
OBJECTS {
cadCmRemoteQueryPollTime,
cadCmRemoteQueryDownChannelPower,
cadCmRemoteQueryStatusTxPower,
cadCmRemoteQueryUpChnlTxTimingOffset,
cadCmRemoteQuerySigQSignalNoise,
cadCmRemoteQuerySigQMicroreflections,
cadCmRemoteQuerySysDescr
}
STATUS current
DESCRIPTION
"Group of objects implemented in Cable Modem
Termination Systems (CMTS) for monitoring cable
modems via CMTS CM Poller."
::= { cadCmRemoteQueryDocsRemoteQueryGroups 2 }
END