2069 lines
71 KiB
Plaintext
2069 lines
71 KiB
Plaintext
CADANT-HW-MEAS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
OBJECT-TYPE, MODULE-IDENTITY, Integer32, Counter32, Counter64, Unsigned32, Gauge32
|
|
FROM SNMPv2-SMI
|
|
DisplayString, MacAddress, TEXTUAL-CONVENTION, TimeStamp, TruthValue
|
|
FROM SNMPv2-TC
|
|
InterfaceIndex, ifIndex
|
|
FROM IF-MIB
|
|
IfDirection
|
|
FROM DOCS-QOS3-MIB
|
|
docsSubmgt3FilterGrpEntry
|
|
FROM DOCS-SUBMGT3-MIB
|
|
TenthdB
|
|
FROM DOCS-IF-MIB
|
|
cadEquipment
|
|
FROM CADANT-PRODUCTS-MIB
|
|
cadIfMacDomainIfIndex
|
|
FROM CADANT-CMTS-LAYER2CMTS-MIB
|
|
cadIfCmtsCmStatusMacAddress
|
|
FROM CADANT-CMTS-MAC-MIB
|
|
cadIf3CmtsCmUsStatusChIfIndex
|
|
FROM CADANT-CMTS-IF3-MIB
|
|
pktcEScTapMediationContentId, pktcEScTapStreamIndex
|
|
FROM PKTC-ES-TAP-MIB
|
|
CadIfDirection, CardId, PortId
|
|
FROM CADANT-TC;
|
|
|
|
cadHardwareMeasMib MODULE-IDENTITY
|
|
LAST-UPDATED "201508270000Z" -- August 27, 2015
|
|
ORGANIZATION
|
|
"Arris International, Inc."
|
|
CONTACT-INFO
|
|
"Arris Technical Support
|
|
E-Mail: support@arrisi.com"
|
|
DESCRIPTION
|
|
"This Mib Module contains all of the counts that are associated
|
|
with hardware in the ARRIS C4 CMTS. Many of these MIB variables
|
|
contain the same counts as found in the standard MIBs. However, the
|
|
grouping of these variables is done for the convenience of the Cadant
|
|
engineering team. These tables can be used to build value-added interfaces
|
|
to the Cadant ARRIS C4 CMTS. "
|
|
|
|
|
|
|
|
REVISION "201508270000Z" -- August 27, 2015
|
|
DESCRIPTION
|
|
"Add cadantDPortMeasOfdmChanUtilization"
|
|
|
|
REVISION "201507130000Z" -- July 13, 2015
|
|
DESCRIPTION
|
|
"Add cadInterfaceHighResUtilizationPercentage and cadInterfaceIntervalOctetsForwarded"
|
|
|
|
REVISION "201506030000Z" -- Jun 3, 2015
|
|
DESCRIPTION
|
|
"Add cadantDPortMeasDfdmIfSpeed, cadantDPortMeasOfdmHighestAvgBitsPerSubc, and
|
|
cadantDPortMeasOfdmNumDataSubc"
|
|
|
|
REVISION "201410140000Z" -- Oct 14, 2014
|
|
DESCRIPTION
|
|
"Support 384 downstream channels per DCAM-B"
|
|
|
|
REVISION "201406130000Z" -- Jun 13, 2014
|
|
DESCRIPTION "Add back in cadFftUpstreamChannelTable"
|
|
|
|
REVISION "201406040000Z" -- Jun 4, 2014
|
|
DESCRIPTION "Add cadDCardIgmpThrottleDropPkts."
|
|
|
|
REVISION "201311220000Z" -- Nov 22, 2013
|
|
DESCRIPTION "Remove cadFftUpstreamChannelTable"
|
|
|
|
REVISION "201210300000Z" -- Oct 30, 2012
|
|
DESCRIPTION "Add cadLaesCountTable"
|
|
|
|
REVISION "201205090000Z" -- May 9, 2012
|
|
DESCRIPTION "Remove cadHWCmUsMeasTable"
|
|
|
|
REVISION "201108310000Z" -- Aug 31, 2011
|
|
DESCRIPTION "Remove cadantUPortMeasMapFrms"
|
|
|
|
REVISION "201106290000Z" -- Jun 29, 2011
|
|
DESCRIPTION "Remove cadSFIDMeasEntry"
|
|
|
|
REVISION "201102280000Z" -- Feb 28, 2011
|
|
DESCRIPTION "Deprecate cadSFIDMeasEntry and add the following MIB objects to cadantUFIDMeasEntry
|
|
cadantUFIDMeasCcfStatsSgmtValids, cadantUFIDMeasCcfStatsSgmtLost and
|
|
cadantUFIDMeasCcfStatsSgmtDrop."
|
|
|
|
REVISION "201102240000Z" -- Feb 24, 2011
|
|
DESCRIPTION "Remove cadSFIDToSIDEntry"
|
|
|
|
REVISION "201102180000Z" -- Feb 18, 2011
|
|
DESCRIPTION "Add cadantUFIDMeasSIDMacIfIndex and cadantUFIDMeasSIDBonded
|
|
to cadantUFIDMeasEntry"
|
|
|
|
REVISION "201011220000Z" -- Nov 22, 2010
|
|
DESCRIPTION "Change indices of cadDFIDMeasEntry as ifIndex and SFID.
|
|
Change indices of cadantUFIDMeasEntry as ifIndex and SID"
|
|
|
|
REVISION "201003090000Z" -- March 9, 2010
|
|
DESCRIPTION "Add cadDCardDhcpV6ThrottleDropPkts and cadDCardNdThrottleDropPkts."
|
|
|
|
REVISION "200811240000Z" -- Nov 24, 2008
|
|
DESCRIPTION "Add cadHWCmUsMeasEntry"
|
|
|
|
REVISION "200811210000Z" -- Nov 21, 2008
|
|
DESCRIPTION "Restructure cadantHWUFIDMeasEntry, rename cadantUFIDMeasUFID to cadantUFIDMeasSID, and
|
|
Add cadantHWMeasUFIDIndex"
|
|
|
|
REVISION "200811050000Z" -- Nov 5, 2008
|
|
DESCRIPTION "Restructure cadSFIDMeasEntry to support docsQosServiceFlowCcfStatsEntry"
|
|
|
|
REVISION "200804240000Z" -- April 24, 2008
|
|
DESCRIPTION "Use ifindex as key for sfid to sid lookup."
|
|
|
|
REVISION "200609140000Z" -- September 14, 2006
|
|
DESCRIPTION "Remove fabric tables and add CPWRED tables to match implementation."
|
|
|
|
REVISION "200604140000Z"
|
|
DESCRIPTION "Added implementation per utilization interval for cadInterfaceUtilizationAvgContSlots."
|
|
|
|
REVISION "200507130000Z"
|
|
DESCRIPTION "Added cadDFIDMeasPolicedDelayPkts for Traffic Shaping feature."
|
|
|
|
REVISION "200412100000Z"
|
|
DESCRIPTION "Extended cadSubMgtPktFilterExtTable to allow for packet capturing."
|
|
|
|
REVISION "200408310000Z"
|
|
DESCRIPTION "Added cadSubMgtPktFilterExtTable to reset docsSubMgtPktFilterMatches."
|
|
|
|
REVISION "200404090000Z"
|
|
DESCRIPTION "Added cadFftUpstreamChannelTable for FFT counts."
|
|
|
|
REVISION "200403090000Z"
|
|
DESCRIPTION "Added cadInterfaceUtilizationTable"
|
|
|
|
REVISION "200402230000Z"
|
|
DESCRIPTION "Added support for per-SID HCS and CRC errors."
|
|
|
|
REVISION "200402180000Z"
|
|
DESCRIPTION "Added cadantDPortMeasIfOutTotalOctets"
|
|
|
|
REVISION "200402150000Z"
|
|
DESCRIPTION "Added support for per UFID microreflection/signalnoise."
|
|
|
|
REVISION "200401240000Z"
|
|
DESCRIPTION "Added cadantDPortMeasAppMcastPkts"
|
|
|
|
REVISION "200312180000Z"
|
|
DESCRIPTION "Added 10 BCM3214 counts to the cadantUPortMeasTable"
|
|
|
|
REVISION "200312100000Z"
|
|
DESCRIPTION " add more arp throttle counts. "
|
|
|
|
REVISION "200309190000Z"
|
|
DESCRIPTION " add more receive error counts to cadantEtherPhyMeasTable"
|
|
|
|
REVISION "200308260000Z"
|
|
DESCRIPTION " add error drop and filter drop counts to UPortMeas table"
|
|
|
|
REVISION "200307300000Z"
|
|
DESCRIPTION " Add support for DHCP packets dropped due to throttling. "
|
|
|
|
REVISION "200205060000Z"
|
|
DESCRIPTION " change cadantUFIDMeasBytsSGreedyDrop to cadantUFIDMeasPktsSGreedyDrop."
|
|
|
|
::= { cadEquipment 2 }
|
|
|
|
--========== Some General Definitions =============
|
|
--
|
|
DFIDIndex ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The 1's-based SFID"
|
|
SYNTAX Unsigned32 (1.. 4294967295)
|
|
|
|
PktClassId ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index assigned to packet classifier entry by the CMTS which is
|
|
unique per service flow."
|
|
SYNTAX Integer32 (1..65535)
|
|
|
|
SFIDIndex ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The 1's-based SFID"
|
|
SYNTAX Integer32 (1..2147483647) -- (1..2^31)
|
|
|
|
UFIDIndex ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The 1's-based UFID"
|
|
SYNTAX Integer32 (1..32768) -- (1..2^15)
|
|
|
|
SIDValue ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The 1's-based SID. 0 is used when there is
|
|
no SID, such as for downstream flows."
|
|
SYNTAX Integer32 (0..16384) -- (0..2^14)
|
|
|
|
TMSide ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Traffic Manager side
|
|
no SID, such as for downstream flows."
|
|
SYNTAX INTEGER { tma(1), tmb(2) }
|
|
|
|
--
|
|
--==================HW Meas Group ==================--
|
|
--
|
|
cadantHWMeasGeneral OBJECT IDENTIFIER ::= { cadHardwareMeasMib 1 }
|
|
|
|
cadantFabActualDepth OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The current depth of the fabric."
|
|
::= { cadantHWMeasGeneral 1 }
|
|
|
|
cadantFabAvgDepth OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The average depth of the fabric."
|
|
::= { cadantHWMeasGeneral 2 }
|
|
|
|
--======= U Port Meas Table ===============
|
|
--
|
|
cadantUPortMeasTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadantUPortMeasEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This table contains information relevant
|
|
to D Card upstream channels."
|
|
::= { cadHardwareMeasMib 3 }
|
|
|
|
|
|
cadantUPortMeasEntry OBJECT-TYPE
|
|
SYNTAX CadantUPortMeasEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " "
|
|
INDEX { cadantUPortMeasCardId, cadantUPortMeasPortId }
|
|
::= { cadantUPortMeasTable 1 }
|
|
|
|
CadantUPortMeasEntry ::= SEQUENCE {
|
|
cadantUPortMeasCardId CardId,
|
|
cadantUPortMeasPortId PortId,
|
|
cadantUPortMeasUcastFrms Counter64,
|
|
cadantUPortMeasMcastFrms Counter64,
|
|
cadantUPortMeasBcastFrms Counter64,
|
|
cadantUPortMeasUcastDataFrms Counter64,
|
|
cadantUPortMeasMcastDataFrms Counter64,
|
|
cadantUPortMeasBcastDataFrms Counter64,
|
|
cadantUPortMeasDiscardFrms Counter64,
|
|
cadantUPortMeasIfInOctets Counter64,
|
|
cadantUPortMeasIfInDataOctets Counter64,
|
|
cadantUPortMeasIfInUnknownProtos Counter64,
|
|
cadantUPortMeasAppMinusBWReqFrms Counter64,
|
|
cadantUPortMeasErroredFrms Counter64,
|
|
cadantUPortMeasFilteredFrms Counter64,
|
|
cadantUPortMeasBcastReqOpps Counter64,
|
|
cadantUPortMeasBcastReqColls Counter64,
|
|
cadantUPortMeasBcastReqNoEnergies Counter64,
|
|
cadantUPortMeasBcastReqRxPwr1s Counter64,
|
|
cadantUPortMeasBcastReqRxPwr2s Counter64,
|
|
cadantUPortMeasInitMaintOpps Counter64,
|
|
cadantUPortMeasInitMaintColls Counter64,
|
|
cadantUPortMeasInitMaintNoEnergies Counter64,
|
|
cadantUPortMeasInitMaintRxPwr1s Counter64,
|
|
cadantUPortMeasInitMaintRxPwr2s Counter64
|
|
}
|
|
|
|
cadantUPortMeasCardId OBJECT-TYPE
|
|
SYNTAX CardId
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { cadantUPortMeasEntry 1 }
|
|
|
|
cadantUPortMeasPortId OBJECT-TYPE
|
|
SYNTAX PortId
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { cadantUPortMeasEntry 2 }
|
|
|
|
cadantUPortMeasUcastFrms OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of unicast frames received on this U channel,
|
|
whether dropped or passed. This includes MAC packets."
|
|
::= { cadantUPortMeasEntry 3 }
|
|
|
|
cadantUPortMeasMcastFrms OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of multicast frames received on this U channel,
|
|
whether dropped or passed. This includes MAC packets."
|
|
::= { cadantUPortMeasEntry 4 }
|
|
|
|
cadantUPortMeasBcastFrms OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of broadcast frames received on this U channel,
|
|
whether dropped or passed. This includes MAC packets."
|
|
::= { cadantUPortMeasEntry 5 }
|
|
|
|
cadantUPortMeasUcastDataFrms OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of unicast frames received on this U channel,
|
|
whether dropped or passed. This does not include MAC packets."
|
|
::= { cadantUPortMeasEntry 6 }
|
|
|
|
cadantUPortMeasMcastDataFrms OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of multicast frames received on this U channel,
|
|
whether dropped or passed. This does not include MAC packets."
|
|
::= { cadantUPortMeasEntry 7 }
|
|
|
|
cadantUPortMeasBcastDataFrms OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of broadcast frames received on this U channel,
|
|
whether dropped or passed. This does not include MAC packets."
|
|
::= { cadantUPortMeasEntry 8 }
|
|
|
|
cadantUPortMeasDiscardFrms OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of frames received on this U channel that were
|
|
dropped for reasons other than ErrorFrms or FilterFrms."
|
|
::= { cadantUPortMeasEntry 9 }
|
|
|
|
cadantUPortMeasIfInOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of octets received on this U channel.
|
|
This includes MAC packets and the length of the MAC header."
|
|
::= { cadantUPortMeasEntry 10 }
|
|
|
|
cadantUPortMeasIfInDataOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of octets received on this U channel.
|
|
This does not include MAC packets or the length of the MAC header."
|
|
::= { cadantUPortMeasEntry 11 }
|
|
|
|
cadantUPortMeasIfInUnknownProtos OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Aggregrate number of MAC frames with unknown protocol. This
|
|
count is neither mutually exclusive with cadantUPortMeasErroredFrms
|
|
nor cadantUPortMeasErroredFrms."
|
|
::= { cadantUPortMeasEntry 12 }
|
|
|
|
cadantUPortMeasAppMinusBWReqFrms OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The number of (unicast) frames received by the software application
|
|
which are not bandwidth request frames. "
|
|
::= { cadantUPortMeasEntry 13 }
|
|
|
|
cadantUPortMeasErroredFrms OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of packets received on this U channel that were
|
|
received in error and dropped. This count is neither mutually exclusive
|
|
with cadantUPortMeasIfInUnknownProtos nor cadantUPortMeasFilteredFrms."
|
|
::= { cadantUPortMeasEntry 15 }
|
|
|
|
cadantUPortMeasFilteredFrms OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of packets received on this U channel that were
|
|
dropped due to a filter rule match and discard. This count is neither
|
|
mutually exclusive with cadantUPortMeasIfInUnknownProtos nor
|
|
cadantUPortMeasErroredFrms."
|
|
::= { cadantUPortMeasEntry 16 }
|
|
|
|
cadantUPortMeasBcastReqOpps OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Broadcast contention request opportunity count"
|
|
::= { cadantUPortMeasEntry 17 }
|
|
|
|
cadantUPortMeasBcastReqColls OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Broadcast contention request opportunities with possible collisions count"
|
|
::= { cadantUPortMeasEntry 18 }
|
|
|
|
cadantUPortMeasBcastReqNoEnergies OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Broadcast contention request opportunities with no energy condition detected"
|
|
::= { cadantUPortMeasEntry 19 }
|
|
|
|
cadantUPortMeasBcastReqRxPwr1s OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Broadcast contention request opportunities with received power level between
|
|
power threshold 2 and power threshold 1"
|
|
::= { cadantUPortMeasEntry 20 }
|
|
|
|
cadantUPortMeasBcastReqRxPwr2s OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Broadcast contention request opportunities with received power level greater
|
|
than power threshold 2"
|
|
::= { cadantUPortMeasEntry 21 }
|
|
|
|
cadantUPortMeasInitMaintOpps OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Initial maintenance opportunities"
|
|
::= { cadantUPortMeasEntry 22 }
|
|
|
|
cadantUPortMeasInitMaintColls OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Initial maintenance opportunities with possible collision"
|
|
::= { cadantUPortMeasEntry 23 }
|
|
|
|
cadantUPortMeasInitMaintNoEnergies OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Initial maintenance opportunities with no energy detected"
|
|
::= { cadantUPortMeasEntry 24 }
|
|
|
|
cadantUPortMeasInitMaintRxPwr1s OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Initial maintenance opportunities with received power level between
|
|
power threshold 2 and power threshold 1"
|
|
::= { cadantUPortMeasEntry 25 }
|
|
|
|
cadantUPortMeasInitMaintRxPwr2s OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Initial maintenance opportunities with received power level greater
|
|
than power threshold 2"
|
|
::= { cadantUPortMeasEntry 26 }
|
|
|
|
--======= D Port Meas Table ===============
|
|
--
|
|
|
|
cadantDPortMeasTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadantDPortMeasEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This table contains information relevant
|
|
to D Card downstream channels."
|
|
::= { cadHardwareMeasMib 4 }
|
|
|
|
cadantDPortMeasEntry OBJECT-TYPE
|
|
SYNTAX CadantDPortMeasEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " "
|
|
INDEX { cadantDPortMeasCardId, cadantDPortMeasPortId }
|
|
::= { cadantDPortMeasTable 1 }
|
|
|
|
CadantDPortMeasEntry ::= SEQUENCE {
|
|
cadantDPortMeasCardId CardId,
|
|
cadantDPortMeasPortId PortId,
|
|
cadantDPortMeasIfOutOctets Counter64,
|
|
cadantDPortMeasIfOutUcastPkts Counter64,
|
|
cadantDPortMeasIfOutMcastPkts Counter64,
|
|
cadantDPortMeasIfOutBcastPkts Counter64,
|
|
cadantDPortMeasIfOutDataOctets Counter64,
|
|
cadantDPortMeasIfOutUcastDataPkts Counter64,
|
|
cadantDPortMeasIfOutMcastDataPkts Counter64,
|
|
cadantDPortMeasIfOutBcastDataPkts Counter64,
|
|
cadantDPortMeasGotNoDMACs Counter64,
|
|
cadantDPortMeasGotNoClasses Counter64,
|
|
cadantDPortMeasSyncPkts Counter64,
|
|
cadantDPortMeasAppUcastPkts Counter64,
|
|
cadantDPortMeasAppMcastPkts Counter64,
|
|
cadantDPortMeasIfOutTotalOctets Counter64,
|
|
cadantDPortMeasOfdmIfSpeed Gauge32,
|
|
cadantDPortMeasOfdmHighestAvgBitsPerSubc Unsigned32,
|
|
cadantDPortMeasOfdmNumDataSubc Unsigned32,
|
|
cadantDPortMeasOfdmChanUtilization Integer32
|
|
}
|
|
|
|
cadantDPortMeasCardId OBJECT-TYPE
|
|
SYNTAX CardId
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { cadantDPortMeasEntry 1 }
|
|
|
|
cadantDPortMeasPortId OBJECT-TYPE
|
|
SYNTAX PortId
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { cadantDPortMeasEntry 2 }
|
|
|
|
cadantDPortMeasIfOutOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Aggregrate number of data bytes sent on this D channel.
|
|
This includes MAC mgmt messages and the length of the
|
|
MAC header."
|
|
::= { cadantDPortMeasEntry 3 }
|
|
|
|
cadantDPortMeasIfOutUcastPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Aggregrate number of unicast data packets sent on this D channel.
|
|
This includes MAC mgmt messages."
|
|
::= { cadantDPortMeasEntry 4 }
|
|
|
|
cadantDPortMeasIfOutMcastPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Aggregrate number of multicast data packets sent on this D channel.
|
|
This includes MAC mgmt messages."
|
|
::= { cadantDPortMeasEntry 5 }
|
|
|
|
cadantDPortMeasIfOutBcastPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Aggregrate number of broadcast data packets sent on this D channel.
|
|
This includes MAC mgmt messages."
|
|
::= { cadantDPortMeasEntry 6 }
|
|
|
|
cadantDPortMeasIfOutDataOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Aggregrate number of data bytes sent on this D channel.
|
|
This does not include MAC mgmt bytes."
|
|
::= { cadantDPortMeasEntry 7 }
|
|
|
|
cadantDPortMeasIfOutUcastDataPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Aggregrate number of unicast data packets sent on this D channel.
|
|
This does not include MAC mgmt messages."
|
|
::= { cadantDPortMeasEntry 8 }
|
|
|
|
cadantDPortMeasIfOutMcastDataPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Aggregrate number of multicast data packets sent on this D channel.
|
|
This does not include MAC mgmt messages."
|
|
::= { cadantDPortMeasEntry 9 }
|
|
|
|
cadantDPortMeasIfOutBcastDataPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Aggregrate number of broadcast data packets sent on this D channel.
|
|
This does not include MAC mgmt messages."
|
|
::= { cadantDPortMeasEntry 10 }
|
|
|
|
cadantDPortMeasGotNoDMACs OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Aggregrate number of ???"
|
|
::= { cadantDPortMeasEntry 11 }
|
|
|
|
cadantDPortMeasGotNoClasses OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Aggregrate number of ???."
|
|
::= { cadantDPortMeasEntry 12 }
|
|
|
|
cadantDPortMeasSyncPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Aggregrate number of sync. frames sent on this D channel."
|
|
::= { cadantDPortMeasEntry 13 }
|
|
|
|
cadantDPortMeasAppUcastPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Aggregrate number of unicast DOCSIS Mac mgmt messages
|
|
sent by application software. "
|
|
::= { cadantDPortMeasEntry 14 }
|
|
|
|
cadantDPortMeasAppMcastPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Aggregrate number of multicast DOCSIS Mac mgmt messages
|
|
sent by application software. "
|
|
::= { cadantDPortMeasEntry 15 }
|
|
|
|
cadantDPortMeasIfOutTotalOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Aggregrate number of octets sent by application software. "
|
|
::= { cadantDPortMeasEntry 16 }
|
|
|
|
cadantDPortMeasOfdmIfSpeed OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Downstream OFDM channel interface speed."
|
|
::= { cadantDPortMeasEntry 17 }
|
|
|
|
cadantDPortMeasOfdmHighestAvgBitsPerSubc OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Highest average bits per subcarrier among all the data profiles of the downstream OFDM channel."
|
|
::= { cadantDPortMeasEntry 18 }
|
|
|
|
cadantDPortMeasOfdmNumDataSubc OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of data subcarrier of the downstream OFDM channel."
|
|
::= { cadantDPortMeasEntry 19 }
|
|
|
|
cadantDPortMeasOfdmChanUtilization OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The utilization of the downstream OFDM channel."
|
|
::= { cadantDPortMeasEntry 20 }
|
|
|
|
--======= UFID Meas Table ===============--
|
|
|
|
cadantUFIDMeasTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadantUFIDMeasEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" "
|
|
::= { cadHardwareMeasMib 6 }
|
|
|
|
cadantUFIDMeasEntry OBJECT-TYPE
|
|
SYNTAX CadantUFIDMeasEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " "
|
|
INDEX { ifIndex, cadantUFIDMeasSID }
|
|
::= { cadantUFIDMeasTable 1 }
|
|
|
|
CadantUFIDMeasEntry ::= SEQUENCE {
|
|
|
|
cadantUFIDMeasSID SIDValue,
|
|
cadantUFIDMeasPktsSGreedyDrop Counter64,
|
|
cadantUFIDMeasBytsOtherDrop Counter64,
|
|
cadantUFIDMeasBytsArrived Counter64,
|
|
cadantUFIDMeasPktsArrived Counter64,
|
|
cadantUFIDMeasSIDCorrecteds Counter64,
|
|
cadantUFIDMeasSIDUnerroreds Counter64,
|
|
cadantUFIDMeasSIDUnCorrecteds Counter64,
|
|
cadantUFIDMeasSIDNoUniqueWordDetecteds Counter64,
|
|
cadantUFIDMeasSIDCollidedBursts Counter64,
|
|
cadantUFIDMeasSIDNoEnergyDetecteds Counter64,
|
|
cadantUFIDMeasSIDLengthErrors Counter64,
|
|
cadantUFIDMeasSIDMACErrors Counter64,
|
|
cadantUFIDMeasMacAddress MacAddress,
|
|
cadantUFIDMeasSCN DisplayString,
|
|
cadantUFIDMeasSFID SFIDIndex,
|
|
cadantUFIDMeasPHSUnknowns Counter64,
|
|
cadantUFIDMeasFragPkts Counter64,
|
|
cadantUFIDMeasIncompletePkts Counter64,
|
|
cadantUFIDMeasConcatBursts Counter64,
|
|
cadantUFIDMeasSIDSignalNoise TenthdB,
|
|
cadantUFIDMeasSIDMicroreflections Integer32,
|
|
cadantUFIDMeasSIDHCSErrors Counter64,
|
|
cadantUFIDMeasSIDCRCErrors Counter64,
|
|
cadantUFIDMeasUFIDIndex UFIDIndex,
|
|
cadantUFIDMeasGateID Unsigned32,
|
|
cadantUFIDMeasSIDMacIfIndex InterfaceIndex,
|
|
cadantUFIDMeasSIDBonded TruthValue,
|
|
cadantUFIDMeasCcfStatsSgmtValids Counter32,
|
|
cadantUFIDMeasCcfStatsSgmtLost Counter32,
|
|
cadantUFIDMeasCcfStatsSgmtDrop Counter32
|
|
}
|
|
|
|
|
|
cadantUFIDMeasSID OBJECT-TYPE
|
|
SYNTAX SIDValue
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The 14 bit (SID)."
|
|
::= { cadantUFIDMeasEntry 3 }
|
|
|
|
cadantUFIDMeasPktsSGreedyDrop OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of Super Greedy pkts dropped for this UFID for
|
|
this MAC layer."
|
|
::= { cadantUFIDMeasEntry 4 }
|
|
|
|
cadantUFIDMeasBytsOtherDrop OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of bytes dropped for this UFID for
|
|
this MAC layer for any other reason than Super Greedy."
|
|
::= { cadantUFIDMeasEntry 5 }
|
|
|
|
cadantUFIDMeasBytsArrived OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of bytes that arrived for this UFID for
|
|
this MAC layer."
|
|
::= { cadantUFIDMeasEntry 6 }
|
|
|
|
cadantUFIDMeasPktsArrived OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of packets that arrived for this UFID for
|
|
this MAC layer."
|
|
::= { cadantUFIDMeasEntry 7 }
|
|
|
|
cadantUFIDMeasSIDCorrecteds OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of bytes that had errors and were corrected
|
|
for this UFID for this MAC layer."
|
|
::= { cadantUFIDMeasEntry 8 }
|
|
|
|
cadantUFIDMeasSIDUnerroreds OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of bytes that had no errors
|
|
for this UFID for this MAC layer."
|
|
::= { cadantUFIDMeasEntry 9 }
|
|
|
|
cadantUFIDMeasSIDUnCorrecteds OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of bytes that had errors and were not
|
|
corrected for this UFID for this MAC layer."
|
|
::= { cadantUFIDMeasEntry 10 }
|
|
|
|
cadantUFIDMeasSIDNoUniqueWordDetecteds OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of bytes allocated for this UFID in which
|
|
no unique code word was detected for this UFID for this MAC layer."
|
|
::= { cadantUFIDMeasEntry 11 }
|
|
|
|
cadantUFIDMeasSIDCollidedBursts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of bytes allocated for this UFID that had
|
|
burst errors in their slots for this UFID for this MAC layer."
|
|
::= { cadantUFIDMeasEntry 12 }
|
|
|
|
cadantUFIDMeasSIDNoEnergyDetecteds OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of bytes allocated for this UFID that had
|
|
no energy detected in their slots for this UFID for this MAC layer."
|
|
::= { cadantUFIDMeasEntry 13 }
|
|
|
|
cadantUFIDMeasSIDLengthErrors OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of bytes allocated for this UFID that had
|
|
no length errors in their slots for this UFID for this MAC layer."
|
|
::= { cadantUFIDMeasEntry 14 }
|
|
|
|
cadantUFIDMeasSIDMACErrors OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of bytes allocated for this UFID that had
|
|
MAC errors in their slots for this UFID for this MAC layer."
|
|
::= { cadantUFIDMeasEntry 15 }
|
|
cadantUFIDMeasMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The MAC address of the CM this flow is associated with."
|
|
::= { cadantUFIDMeasEntry 17 }
|
|
|
|
cadantUFIDMeasSCN OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The Service Class Name for this flow."
|
|
::= { cadantUFIDMeasEntry 18 }
|
|
|
|
cadantUFIDMeasSFID OBJECT-TYPE
|
|
SYNTAX SFIDIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The SFID this UFID(SID) is for."
|
|
::= { cadantUFIDMeasEntry 19 }
|
|
|
|
cadantUFIDMeasPHSUnknowns OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"refer to docsQosServiceFlowPHSUnknowns"
|
|
::= { cadantUFIDMeasEntry 20 }
|
|
|
|
cadantUFIDMeasFragPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"refer to docsQosUpstreamFragPkts"
|
|
::= { cadantUFIDMeasEntry 21 }
|
|
|
|
cadantUFIDMeasIncompletePkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"refer to docsQosUpstreamIncompletePkts"
|
|
::= { cadantUFIDMeasEntry 22 }
|
|
|
|
cadantUFIDMeasConcatBursts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"refer to docsQosUpstreamConcatBursts"
|
|
::= { cadantUFIDMeasEntry 23 }
|
|
|
|
cadantUFIDMeasSIDSignalNoise OBJECT-TYPE
|
|
SYNTAX TenthdB
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"refer to docsIfCmtsCmStatusSignalNoise"
|
|
::= { cadantUFIDMeasEntry 24 }
|
|
|
|
cadantUFIDMeasSIDMicroreflections OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"refer to docsIfCmtsCmStatusMicroreflections"
|
|
::= { cadantUFIDMeasEntry 25 }
|
|
|
|
cadantUFIDMeasSIDHCSErrors OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of MAC HCS errors seen for this SID."
|
|
::= { cadantUFIDMeasEntry 26 }
|
|
|
|
cadantUFIDMeasSIDCRCErrors OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of MAC CRC errors seen for this SID."
|
|
::= { cadantUFIDMeasEntry 27 }
|
|
|
|
cadantUFIDMeasUFIDIndex OBJECT-TYPE
|
|
SYNTAX UFIDIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The 15 bit (UFID)."
|
|
::= { cadantUFIDMeasEntry 28 }
|
|
|
|
cadantUFIDMeasGateID OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The DQoS or PCMM gate ID corresponding to the flow,
|
|
A zero in this field indicates no gate is associated with the flow."
|
|
::= { cadantUFIDMeasEntry 29 }
|
|
|
|
cadantUFIDMeasSIDMacIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The cable Mac domain ifIndex the SID is associated with."
|
|
::= { cadantUFIDMeasEntry 30 }
|
|
|
|
cadantUFIDMeasSIDBonded OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This object indicates whether a SID is associated with
|
|
a CCF service flow."
|
|
::= { cadantUFIDMeasEntry 31 }
|
|
|
|
cadantUFIDMeasCcfStatsSgmtValids OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "segments"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute contains the number of segments counted
|
|
on this service flow regardless of whether the
|
|
fragment was correctly reassembled into valid packets.
|
|
Discontinuities in the value of this counter can
|
|
occur at reinitialization of the managed system."
|
|
::= { cadantUFIDMeasEntry 32 }
|
|
|
|
cadantUFIDMeasCcfStatsSgmtLost OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "segments"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute counts the number of segments which
|
|
the CMTS segment reassembly function determines were
|
|
lost. Discontinuities in the value of this counter
|
|
can occur at reinitialization of the managed system."
|
|
::= { cadantUFIDMeasEntry 33 }
|
|
|
|
cadantUFIDMeasCcfStatsSgmtDrop OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "segments"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute counts the number of segments which
|
|
the CMTS segment reassembly function determines were
|
|
dropped. Discontinuities in the value of this counter
|
|
can occur at reinitialization of the managed system."
|
|
::= { cadantUFIDMeasEntry 34 }
|
|
|
|
|
|
--
|
|
--================== EtherPhys Meas Table ==============================-
|
|
--
|
|
|
|
cadantEtherPhyMeasTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadantEtherPhyMeasEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" "
|
|
::= { cadHardwareMeasMib 10 }
|
|
|
|
cadantEtherPhyMeasEntry OBJECT-TYPE
|
|
SYNTAX CadantEtherPhyMeasEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " "
|
|
INDEX { cadantEtherPhyMeasCardId, cadantEtherPhyMeasPortId }
|
|
::= { cadantEtherPhyMeasTable 1 }
|
|
|
|
CadantEtherPhyMeasEntry ::= SEQUENCE {
|
|
cadantEtherPhyMeasCardId CardId,
|
|
cadantEtherPhyMeasPortId PortId,
|
|
|
|
cadantEtherPhyMeasRxOctOK Counter64,
|
|
cadantEtherPhyMeasRxUniOK Counter64,
|
|
cadantEtherPhyMeasRxMultiOK Counter64,
|
|
cadantEtherPhyMeasRxBroadOK Counter64,
|
|
cadantEtherPhyMeasRxOverflow Counter64,
|
|
cadantEtherPhyMeasRxNormAlign Counter64,
|
|
cadantEtherPhyMeasRxNormCRC Counter64,
|
|
cadantEtherPhyMeasRxLongOK Counter64,
|
|
cadantEtherPhyMeasRxLongCRC Counter64,
|
|
cadantEtherPhyMeasRxFalsCRS Counter64,
|
|
cadantEtherPhyMeasRxSymbolErrors Counter64,
|
|
cadantEtherPhyMeasRxPause Counter64,
|
|
cadantEtherPhyMeasTxOctOK Counter64,
|
|
cadantEtherPhyMeasTxUniOK Counter64,
|
|
cadantEtherPhyMeasTxMultiOK Counter64,
|
|
cadantEtherPhyMeasTxBroadOK Counter64,
|
|
cadantEtherPhyMeasTxScol Counter64,
|
|
cadantEtherPhyMeasTxMcol Counter64,
|
|
cadantEtherPhyMeasTxDeferred Counter64,
|
|
cadantEtherPhyMeasTxLcol Counter64,
|
|
cadantEtherPhyMeasTxCcol Counter64,
|
|
cadantEtherPhyMeasTxErr Counter64,
|
|
cadantEtherPhyMeasTxPause Counter64,
|
|
cadantEtherPhyMeasRxShortOK Counter64,
|
|
cadantEtherPhyMeasRxShortCRC Counter64,
|
|
cadantEtherPhyMeasRxRunt Counter64,
|
|
cadantEtherPhyMeasRxOctBad Counter64
|
|
}
|
|
|
|
cadantEtherPhyMeasCardId OBJECT-TYPE
|
|
SYNTAX CardId
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { cadantEtherPhyMeasEntry 1 }
|
|
|
|
cadantEtherPhyMeasPortId OBJECT-TYPE
|
|
SYNTAX PortId
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { cadantEtherPhyMeasEntry 2 }
|
|
|
|
cadantEtherPhyMeasRxOctOK OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 3 }
|
|
|
|
cadantEtherPhyMeasRxUniOK OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 4 }
|
|
|
|
cadantEtherPhyMeasRxMultiOK OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 5 }
|
|
|
|
cadantEtherPhyMeasRxBroadOK OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 6 }
|
|
|
|
cadantEtherPhyMeasRxOverflow OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 7 }
|
|
|
|
cadantEtherPhyMeasRxNormAlign OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 8 }
|
|
|
|
cadantEtherPhyMeasRxNormCRC OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 9 }
|
|
|
|
cadantEtherPhyMeasRxLongOK OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 10 }
|
|
|
|
cadantEtherPhyMeasRxLongCRC OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 11 }
|
|
|
|
cadantEtherPhyMeasRxFalsCRS OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 12 }
|
|
|
|
cadantEtherPhyMeasRxSymbolErrors OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 13 }
|
|
|
|
cadantEtherPhyMeasRxPause OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 14 }
|
|
|
|
cadantEtherPhyMeasTxOctOK OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 15 }
|
|
|
|
cadantEtherPhyMeasTxUniOK OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 16 }
|
|
|
|
cadantEtherPhyMeasTxMultiOK OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 17 }
|
|
|
|
cadantEtherPhyMeasTxBroadOK OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 18 }
|
|
|
|
cadantEtherPhyMeasTxScol OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 19 }
|
|
|
|
cadantEtherPhyMeasTxMcol OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 20 }
|
|
|
|
cadantEtherPhyMeasTxDeferred OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 21 }
|
|
|
|
cadantEtherPhyMeasTxLcol OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 22 }
|
|
|
|
cadantEtherPhyMeasTxCcol OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 23 }
|
|
|
|
cadantEtherPhyMeasTxErr OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 24 }
|
|
|
|
cadantEtherPhyMeasTxPause OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 25 }
|
|
|
|
cadantEtherPhyMeasRxShortOK OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 26 }
|
|
|
|
cadantEtherPhyMeasRxShortCRC OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 27 }
|
|
|
|
cadantEtherPhyMeasRxRunt OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 28 }
|
|
|
|
cadantEtherPhyMeasRxOctBad OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ."
|
|
::= { cadantEtherPhyMeasEntry 29 }
|
|
|
|
|
|
|
|
--
|
|
--================== DFID Meas Table ==============================-
|
|
--
|
|
|
|
cadDFIDMeasTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadDFIDMeasEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains DFID-specific counts."
|
|
::= { cadHardwareMeasMib 14 }
|
|
|
|
cadDFIDMeasEntry OBJECT-TYPE
|
|
SYNTAX CadDFIDMeasEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " "
|
|
INDEX { ifIndex, cadDFIDMeasIndex }
|
|
::= { cadDFIDMeasTable 1 }
|
|
|
|
CadDFIDMeasEntry ::= SEQUENCE {
|
|
cadDFIDMeasIndex SFIDIndex,
|
|
cadDFIDMeasBytsArrived Counter64,
|
|
cadDFIDMeasPktsArrived Counter64,
|
|
cadDFIDMeasBytsDropped Counter64,
|
|
cadDFIDMeasPktsDropped Counter64,
|
|
cadDFIDMeasBytsUnkDropped Counter64,
|
|
cadDFIDMeasDFID DFIDIndex,
|
|
cadDFIDMeasPHSUnknowns Counter64,
|
|
cadDFIDMeasMacAddress MacAddress,
|
|
cadDFIDMeasSCN DisplayString,
|
|
cadDFIDMeasPolicedDelayPkts Counter64,
|
|
cadDFIDMeasGateID Unsigned32
|
|
}
|
|
|
|
|
|
cadDFIDMeasIndex OBJECT-TYPE
|
|
SYNTAX SFIDIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The SFID these DFID counts are for."
|
|
::= { cadDFIDMeasEntry 3 }
|
|
|
|
cadDFIDMeasBytsArrived OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of bytes arriving to go out,
|
|
but not necessarily transmitted."
|
|
::= { cadDFIDMeasEntry 4 }
|
|
|
|
cadDFIDMeasPktsArrived OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of packets arriving to go out,
|
|
but not necessarily transmitted."
|
|
::= { cadDFIDMeasEntry 5 }
|
|
|
|
cadDFIDMeasBytsDropped OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of bytes dropped."
|
|
::= { cadDFIDMeasEntry 6 }
|
|
|
|
cadDFIDMeasPktsDropped OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of packets dropped."
|
|
::= { cadDFIDMeasEntry 7 }
|
|
|
|
cadDFIDMeasBytsUnkDropped OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The aggregrate number of bytes dropped due to unknown DMAC."
|
|
::= { cadDFIDMeasEntry 8 }
|
|
|
|
cadDFIDMeasDFID OBJECT-TYPE
|
|
SYNTAX DFIDIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The DFID."
|
|
::= { cadDFIDMeasEntry 9 }
|
|
|
|
cadDFIDMeasPHSUnknowns OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"refer to docsQosServiceFlowPHSUnknowns"
|
|
::= { cadDFIDMeasEntry 10 }
|
|
|
|
cadDFIDMeasMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The MAC address of the CM this flow is associated with."
|
|
::= { cadDFIDMeasEntry 11 }
|
|
|
|
cadDFIDMeasSCN OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The Service Class Name for this flow."
|
|
::= { cadDFIDMeasEntry 12 }
|
|
|
|
cadDFIDMeasPolicedDelayPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"refer to docsQosServiceFlowPolicedDelayPkts"
|
|
::= { cadDFIDMeasEntry 13 }
|
|
|
|
cadDFIDMeasGateID OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The DQoS or PCMM gate ID corresponding to the flow,
|
|
A zero in this field indicates no gate is associated with the flow."
|
|
::= { cadDFIDMeasEntry 14 }
|
|
|
|
|
|
--
|
|
--================= Classifier Match Count Table ==============================-
|
|
--
|
|
|
|
cadQosPktClassMeasTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadQosPktClassMeasEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This table contains just one data member: cadQosPktClassMeasPkts,
|
|
which is equivalent to docsQosPktClassPkts in qos-draft-04."
|
|
::= { cadHardwareMeasMib 16 }
|
|
|
|
cadQosPktClassMeasEntry OBJECT-TYPE
|
|
SYNTAX CadQosPktClassMeasEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " "
|
|
INDEX { cadQosPktClassMeasIfIndex,
|
|
cadQosPktClassMeasSFID,
|
|
cadQosPktClassMeasPktClassId }
|
|
::= { cadQosPktClassMeasTable 1 }
|
|
|
|
CadQosPktClassMeasEntry ::= SEQUENCE {
|
|
cadQosPktClassMeasIfIndex InterfaceIndex,
|
|
cadQosPktClassMeasSFID SFIDIndex,
|
|
cadQosPktClassMeasPktClassId PktClassId,
|
|
cadQosPktClassMeasPkts Counter64
|
|
}
|
|
|
|
cadQosPktClassMeasIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The ifIndex of ifType 127 for this classifier."
|
|
::= { cadQosPktClassMeasEntry 1 }
|
|
|
|
cadQosPktClassMeasSFID OBJECT-TYPE
|
|
SYNTAX SFIDIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The Service Flow ID this classifier is for."
|
|
::= { cadQosPktClassMeasEntry 2 }
|
|
|
|
cadQosPktClassMeasPktClassId OBJECT-TYPE
|
|
SYNTAX PktClassId
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The ID of this classifier, which only need be unique for a given Service Flow ID."
|
|
::= { cadQosPktClassMeasEntry 3 }
|
|
|
|
cadQosPktClassMeasPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The number of packets that have been classified using this classifier on this flow."
|
|
::= { cadQosPktClassMeasEntry 4 }
|
|
|
|
|
|
--
|
|
--=========== Interface counts, to support If and IfX tables
|
|
--
|
|
cadIfMeasTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadIfMeasEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This table is designed to concurrently support the counters
|
|
defined in the ifTable and the ifXTable. Every row that appears
|
|
in this table should have a corresponding row in both the ifTable
|
|
and the ifXTable. However, not every row in the ifTable and
|
|
ifXTable will appear in this table."
|
|
::= { cadHardwareMeasMib 18 }
|
|
|
|
cadIfMeasEntry OBJECT-TYPE
|
|
SYNTAX CadIfMeasEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
INDEX { ifIndex }
|
|
::= { cadIfMeasTable 1 }
|
|
|
|
CadIfMeasEntry ::= SEQUENCE {
|
|
cadIfInOctets Counter64,
|
|
cadIfInUcastPkts Counter64,
|
|
cadIfInMulticastPkts Counter64,
|
|
cadIfInBroadcastPkts Counter64,
|
|
cadIfInDiscards Counter64,
|
|
cadIfInErrors Counter64,
|
|
cadIfInUnknownProtos Counter64,
|
|
cadIfOutOctets Counter64,
|
|
cadIfOutUcastPkts Counter64,
|
|
cadIfOutMulticastPkts Counter64,
|
|
cadIfOutBroadcastPkts Counter64,
|
|
cadIfOutDiscards Counter64,
|
|
cadIfOutErrors Counter64
|
|
}
|
|
|
|
cadIfInOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" See the IF-MIB's corresponding object's DESCRIPTION for a
|
|
description of this object."
|
|
::= { cadIfMeasEntry 1 }
|
|
|
|
cadIfInUcastPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" See the IF-MIB's corresponding object's DESCRIPTION for a
|
|
description of this object."
|
|
::= { cadIfMeasEntry 2 }
|
|
|
|
cadIfInMulticastPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" See the IF-MIB's corresponding object's DESCRIPTION for a
|
|
description of this object."
|
|
::= { cadIfMeasEntry 3 }
|
|
|
|
cadIfInBroadcastPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" See the IF-MIB's corresponding object's DESCRIPTION for a
|
|
description of this object."
|
|
::= { cadIfMeasEntry 4 }
|
|
|
|
cadIfInDiscards OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" See the IF-MIB's corresponding object's DESCRIPTION for a
|
|
description of this object."
|
|
::= { cadIfMeasEntry 5 }
|
|
|
|
cadIfInErrors OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" See the IF-MIB's corresponding object's DESCRIPTION for a
|
|
description of this object."
|
|
::= { cadIfMeasEntry 6 }
|
|
|
|
cadIfInUnknownProtos OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" See the IF-MIB's corresponding object's DESCRIPTION for a
|
|
description of this object."
|
|
::= { cadIfMeasEntry 7 }
|
|
|
|
cadIfOutOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" See the IF-MIB's corresponding object's DESCRIPTION for a
|
|
description of this object."
|
|
::= { cadIfMeasEntry 8 }
|
|
|
|
cadIfOutUcastPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" See the IF-MIB's corresponding object's DESCRIPTION for a
|
|
description of this object."
|
|
::= { cadIfMeasEntry 9 }
|
|
|
|
cadIfOutMulticastPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" See the IF-MIB's corresponding object's DESCRIPTION for a
|
|
description of this object."
|
|
::= { cadIfMeasEntry 10 }
|
|
|
|
cadIfOutBroadcastPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" See the IF-MIB's corresponding object's DESCRIPTION for a
|
|
description of this object."
|
|
::= { cadIfMeasEntry 11 }
|
|
|
|
cadIfOutDiscards OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" See the IF-MIB's corresponding object's DESCRIPTION for a
|
|
description of this object."
|
|
::= { cadIfMeasEntry 12 }
|
|
|
|
cadIfOutErrors OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" See the IF-MIB's corresponding object's DESCRIPTION for a
|
|
description of this object."
|
|
::= { cadIfMeasEntry 13 }
|
|
|
|
|
|
--
|
|
--======= D Card Meas Table ===============
|
|
--
|
|
|
|
cadDCardMeasTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadDCardMeasEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This table contains information relevant
|
|
to D Card counts."
|
|
::= { cadHardwareMeasMib 20 }
|
|
|
|
cadDCardMeasEntry OBJECT-TYPE
|
|
SYNTAX CadDCardMeasEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " "
|
|
INDEX { cadDCardMeasCardId }
|
|
::= { cadDCardMeasTable 1 }
|
|
|
|
CadDCardMeasEntry ::= SEQUENCE {
|
|
cadDCardMeasCardId CardId,
|
|
cadDCardIpInReceives Counter64,
|
|
cadDCardIpInHdrErrors Counter64,
|
|
cadDCardIpInAddrErrors Counter64,
|
|
cadDCardDhcpThrottleDropPkts Counter64,
|
|
cadDCardArpThrottleDropPkts Counter64,
|
|
cadDCardDhcpV6ThrottleDropPkts Counter64,
|
|
cadDCardNdThrottleDropPkts Counter64,
|
|
cadDCardIgmpThrottleDropPkts Counter64
|
|
}
|
|
|
|
cadDCardMeasCardId OBJECT-TYPE
|
|
SYNTAX CardId
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { cadDCardMeasEntry 1 }
|
|
|
|
cadDCardIpInReceives OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The contribution to ipInRecevies for this
|
|
particular D Card."
|
|
::= { cadDCardMeasEntry 2 }
|
|
|
|
cadDCardIpInHdrErrors OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The contribution to ipInHdrErrors for this
|
|
particular D Card."
|
|
::= { cadDCardMeasEntry 3 }
|
|
|
|
cadDCardIpInAddrErrors OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The contribution to ipInAddrErrors for this
|
|
particular D Card."
|
|
::= { cadDCardMeasEntry 4 }
|
|
|
|
cadDCardDhcpThrottleDropPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of dropped DHCP requests for this D Card."
|
|
::= { cadDCardMeasEntry 5 }
|
|
|
|
cadDCardArpThrottleDropPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of dropped ARP requests for this D Card."
|
|
::= { cadDCardMeasEntry 6 }
|
|
|
|
cadDCardDhcpV6ThrottleDropPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of dropped IPV6 DHCP requests for this D Card."
|
|
::= { cadDCardMeasEntry 7 }
|
|
|
|
cadDCardNdThrottleDropPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of dropped IPV6 ND requests for this D Card."
|
|
::= { cadDCardMeasEntry 8 }
|
|
|
|
cadDCardIgmpThrottleDropPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of dropped IGMP messages for this UCAM."
|
|
::= { cadDCardMeasEntry 9 }
|
|
|
|
--
|
|
-- Interface Utilization Table
|
|
--
|
|
|
|
cadInterfaceUtilizationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadInterfaceUtilizationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reports utilization statistics for attached interfaces."
|
|
::= { cadHardwareMeasMib 23 }
|
|
|
|
cadInterfaceUtilizationEntry OBJECT-TYPE
|
|
SYNTAX CadInterfaceUtilizationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Utilization statistics for a single interface. An entry exists in this table for each
|
|
ifEntry with an ifType equal to docsCableDownstreamInterface (128),
|
|
docsCableUpstreamInterface (129), docsCableUpstreamChannel (205), ethernet(6), or
|
|
gigabitEthernet(117)."
|
|
INDEX { ifIndex, cadInterfaceUtilizationDirection }
|
|
::= { cadInterfaceUtilizationTable 1 }
|
|
|
|
CadInterfaceUtilizationEntry ::= SEQUENCE {
|
|
cadInterfaceUtilizationDirection CadIfDirection,
|
|
cadInterfaceUtilizationPercentage Integer32,
|
|
cadInterfaceUtilizationAvgContSlots Integer32,
|
|
cadInterfaceHighResUtilizationPercentage Integer32,
|
|
cadInterfaceIntervalOctetsForwarded Counter64
|
|
}
|
|
|
|
cadInterfaceUtilizationDirection OBJECT-TYPE
|
|
SYNTAX CadIfDirection
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The direction of flow this utilization is for. Cable upstream interfaces
|
|
will only have a value of 'in' for this object. Likewise, cable downstream
|
|
interfaces will only hav a value of 'out' for this object. Full-duplex interfaces,
|
|
such as fastEthernet and gigabitEthernet interfaces, will have both 'in' and 'out'
|
|
rows."
|
|
::= { cadInterfaceUtilizationEntry 1 }
|
|
|
|
cadInterfaceUtilizationPercentage OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The calculated and truncated utilization index for this interface, accurate
|
|
as of the most recent docsIfCmtsChannelUtilizationInterval."
|
|
::= { cadInterfaceUtilizationEntry 2 }
|
|
|
|
cadInterfaceUtilizationAvgContSlots OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable for ifType of docsCableUpstreamChannel (205) only.
|
|
The average percentage of contention mini-slots for upstream channel.
|
|
This ratio is calculated the most recent utilization interval.
|
|
|
|
Formula:
|
|
Upstream contention mini-slots utilization =
|
|
(100 * ((contention mini-slots ) / (total mini-slots))"
|
|
::= { cadInterfaceUtilizationEntry 3 }
|
|
|
|
cadInterfaceHighResUtilizationPercentage OBJECT-TYPE
|
|
SYNTAX Integer32 (0..10000)
|
|
UNITS "Hundredth of a percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The calculated and truncated utilization index for this interface,
|
|
accurate (to 0.01% resolution) as of the most recent docsIfCmtsChannelUtilizationInterval."
|
|
::= { cadInterfaceUtilizationEntry 4 }
|
|
|
|
cadInterfaceIntervalOctetsForwarded OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets forwarded since the most recent docsIfCmtsChannelUtilizationInterval.
|
|
Note that this count will only apply to the following interface types: Ethernet,
|
|
Link-Aggregate. For all other interface types this value will display 0"
|
|
::= { cadInterfaceUtilizationEntry 5 }
|
|
|
|
--
|
|
-- FFT Status Table removed
|
|
--
|
|
-- cadFftUpstreamChannelTable OBJECT-TYPE
|
|
-- ::= { cadHardwareMeasMib 24 }
|
|
|
|
|
|
--
|
|
-- IP filter match counter clear table
|
|
--
|
|
cadSubMgtPktFilterExtTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadSubMgtPktFilterExtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table augments the docsSubMgtPktFilterTable. In its
|
|
current form, it is used to clear docsSubMgtPktFilterMatches
|
|
and keep track of the change."
|
|
::= { cadHardwareMeasMib 25 }
|
|
|
|
cadSubMgtPktFilterExtEntry OBJECT-TYPE
|
|
SYNTAX CadSubMgtPktFilterExtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For every docsSubmgt3FilterGrpEntry, there is a matching
|
|
cadSubMgtPktFilterExtEntry."
|
|
AUGMENTS { docsSubmgt3FilterGrpEntry }
|
|
::= { cadSubMgtPktFilterExtTable 1 }
|
|
|
|
CadSubMgtPktFilterExtEntry ::= SEQUENCE {
|
|
cadSubMgtPktFilterMatchesReset TruthValue,
|
|
cadSubMgtPktFilterLastChanged TimeStamp,
|
|
cadSubMgtPktFilterCaptureEnabled TruthValue
|
|
}
|
|
|
|
cadSubMgtPktFilterMatchesReset OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object always return false(2) when read. If the value
|
|
false(2) is assigned to this object, no action is taken.
|
|
However, if this object it set to the value true(1), the
|
|
corresponding docsSubMgtPktFilterMatches counter object is
|
|
set to 0 and cadSubMgtPktFilterLastChanged is set to the current
|
|
time."
|
|
DEFVAL { false }
|
|
::= { cadSubMgtPktFilterExtEntry 1 }
|
|
|
|
cadSubMgtPktFilterLastChanged OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time at which docsSubMgtPktFilterMatches might have
|
|
experienced a discontinuity, such as when
|
|
cadSubMgtPktFilterMatchesReset is set to true(1) or when any
|
|
of the parameters in the docsSubMgtPktFilterTable affecting
|
|
filtering last changed."
|
|
::= { cadSubMgtPktFilterExtEntry 2 }
|
|
|
|
cadSubMgtPktFilterCaptureEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether packets matching this filter are captured
|
|
for possible debug logging. A value of true indicates that
|
|
packets matching this filter will be captured. A value of
|
|
false indicates that packets matching this filter will not
|
|
be captured for later debuggging."
|
|
DEFVAL { false }
|
|
::= { cadSubMgtPktFilterExtEntry 3 }
|
|
|
|
|
|
|
|
--
|
|
-- Cadant LAES count table
|
|
--
|
|
cadLaesCountTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadLaesCountEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table references pktcEScTapStreamTable"
|
|
::= { cadHardwareMeasMib 26 }
|
|
|
|
cadLaesCountEntry OBJECT-TYPE
|
|
SYNTAX CadLaesCountEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For every cadLaesCountEntry, there is a matching
|
|
pktcEScTapStreamEntry."
|
|
INDEX { pktcEScTapMediationContentId, pktcEScTapStreamIndex }
|
|
::= { cadLaesCountTable 1 }
|
|
|
|
CadLaesCountEntry ::= SEQUENCE {
|
|
cadLaesCountMacDomainIfIndex InterfaceIndex,
|
|
cadLaesCountStreamDirection IfDirection,
|
|
cadLaesCountInterceptedPackets Counter32,
|
|
cadLaesCountInterceptDrops Counter32
|
|
}
|
|
|
|
cadLaesCountMacDomainIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the cable Mac domain interface index that the
|
|
LAES stream is associated with."
|
|
|
|
::= { cadLaesCountEntry 1 }
|
|
|
|
cadLaesCountStreamDirection OBJECT-TYPE
|
|
SYNTAX IfDirection
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates either downstream or upstream direction that the
|
|
LAES stream is associated with."
|
|
::= { cadLaesCountEntry 2 }
|
|
|
|
cadLaesCountInterceptedPackets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates number of intercepted packets are sent of the LAES stream."
|
|
::= { cadLaesCountEntry 3 }
|
|
|
|
cadLaesCountInterceptDrops OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates number of intercepted packets are dropped of the LAES stream."
|
|
::= { cadLaesCountEntry 4 }
|
|
|
|
--
|
|
-- FFT Status Table
|
|
--
|
|
cadFftUpstreamChannelTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadFftUpstreamChannelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reports current FFT operation status."
|
|
::= { cadHardwareMeasMib 24 }
|
|
|
|
cadFftUpstreamChannelEntry OBJECT-TYPE
|
|
SYNTAX CadFftUpstreamChannelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FFT status for a single upstream channel with ifType
|
|
docsCableUpstreamInterface(129)."
|
|
INDEX { ifIndex }
|
|
::= { cadFftUpstreamChannelTable 1 }
|
|
|
|
CadFftUpstreamChannelEntry ::= SEQUENCE {
|
|
cadFftInProgress TruthValue,
|
|
cadFftCurrentTriggers Unsigned32
|
|
}
|
|
|
|
cadFftInProgress OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current state on the FFT capture. "
|
|
::= { cadFftUpstreamChannelEntry 1 }
|
|
|
|
cadFftCurrentTriggers OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times the FFT capture has triggered and
|
|
transferred data from the Broadcom device."
|
|
::= { cadFftUpstreamChannelEntry 2 }
|
|
|
|
END
|
|
|