3950 lines
132 KiB
Plaintext
3950 lines
132 KiB
Plaintext
CADANT-CMTS-SYSTEM-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
OBJECT-TYPE, MODULE-IDENTITY, Counter32, Integer32, IpAddress, Unsigned32
|
|
FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
TruthValue, DisplayString, MacAddress, DateAndTime, RowStatus
|
|
FROM SNMPv2-TC
|
|
InetAddressType, InetAddress, InetAddressIPv4, InetAddressIPv6
|
|
FROM INET-ADDRESS-MIB
|
|
InterfaceIndexOrZero
|
|
FROM IF-MIB
|
|
cadSystem
|
|
FROM CADANT-PRODUCTS-MIB
|
|
CardId, AdminState, ServerType, OverloadThreshold, AdminSrcAddrType
|
|
FROM CADANT-TC
|
|
BitRate
|
|
FROM DOCS-QOS3-MIB
|
|
TenthdB
|
|
FROM DOCS-IF-MIB
|
|
SnmpAdminString, SnmpEngineID
|
|
FROM SNMP-FRAMEWORK-MIB;
|
|
|
|
cadSystemMib MODULE-IDENTITY
|
|
LAST-UPDATED "201511110000Z" -- November 11, 2015
|
|
ORGANIZATION
|
|
"ARRIS Group, Inc."
|
|
CONTACT-INFO
|
|
"Arris Technical Support
|
|
Phone: +1 630 281 3000
|
|
E-Mail: support@arris.com"
|
|
DESCRIPTION
|
|
"Arris E6000 system parameters and constants"
|
|
|
|
-- REVISION "201512150000Z"
|
|
-- DESCRIPTION
|
|
-- "Add operation mode to prevent modems from using an upstream frequency beyond 42 MHz."
|
|
REVISION "201511110000Z" -- November 11, 2015
|
|
DESCRIPTION
|
|
"Add ofdmSparingCleanupOff(8) to cadSysSpOperMode"
|
|
REVISION "201511060000Z" -- November 6, 2015
|
|
DESCRIPTION
|
|
"Adjust default network packet/event rates."
|
|
REVISION "201509100000Z" -- Sept 10, 2015
|
|
DESCRIPTION
|
|
"Add upDownTrapIfDescrOff(7) to cadSysSpOperMode"
|
|
REVISION "201507210000Z" -- July 21, 2015
|
|
DESCRIPTION
|
|
"Change upper limit of cadSysLicensePorts from 1000 to 5000."
|
|
REVISION "201506030000Z" -- June 3, 2015
|
|
DESCRIPTION
|
|
"Change upper limit of cadSysLicensePorts from 256 to 1000."
|
|
REVISION "201503300000Z" -- March 30, 2015
|
|
DESCRIPTION
|
|
"Change default value of cadSysContact from support@arrisi.com to support@arris.com."
|
|
REVISION "201503050000Z" -- March 5, 2015
|
|
DESCRIPTION
|
|
"Increase the allowed IGMP throttle rate."
|
|
REVISION "201410070000Z" -- Oct 7, 2014
|
|
DESCRIPTION
|
|
"Add cadSysProcErmRpcPacketRate, cadSysProcErmRpcPacketsReceivedPassed and
|
|
cadSysProcErmRpcPacketsReceivedDropped."
|
|
REVISION "201408050000Z" -- Aug 5, 2014
|
|
DESCRIPTION
|
|
"Add cadSysAES128Enable."
|
|
REVISION "201406100000Z" -- June 10, 2014
|
|
DESCRIPTION
|
|
"Add configuration for flap list insertion."
|
|
REVISION "201405290000Z" -- May 29, 2014
|
|
DESCRIPTION
|
|
"Remove support for reduced TCS generation (i.e. remove tcsReducedOff(8) from cadSysSpOperMode)."
|
|
REVISION "201405210000Z" -- May 21, 2014
|
|
DESCRIPTION
|
|
"Changed cadSysMtceDULPacketInterval default from 30000 to 10000"
|
|
REVISION "201405140000Z" -- May 14, 2014
|
|
DESCRIPTION
|
|
"Remove cadSysModPriUsInTcsEnabled and cadSysModPriUsDbcEnabled"
|
|
REVISION "201404250000Z" -- April 25, 2014
|
|
DESCRIPTION
|
|
"Change default value of cadSysProcVrepPacketRate and cadSysProcVpmePacketRate"
|
|
REVISION "201404100000Z" -- April 10, 2014
|
|
DESCRIPTION
|
|
"Add cadSysProcVrepPacketRate, cadSysProcVpmePacketRate,
|
|
cadSysProcVrepPacketsReceivedPassed, cadSysProcVrepPacketsReceivedDropped,
|
|
cadSysProcVpmePacketsReceivedPassed and cadSysProcVpmePacketsReceivedDropped."
|
|
REVISION "201403130000Z" -- March 13, 2014
|
|
DESCRIPTION
|
|
"Add cadSysProcLacpPacketRate, cadSysProcLacpPacketsReceivedPassed and
|
|
cadSysProcLacpPacketsReceivedDropped."
|
|
REVISION "201403060000Z" -- March 6, 2014
|
|
DESCRIPTION
|
|
"Add cadSysPatchParams."
|
|
REVISION "201402210000Z" -- Feburary 21, 2014
|
|
DESCRIPTION
|
|
"Add cadSysModPriUsInTcsEnabled and cadSysModPriUsDbcEnabled"
|
|
REVISION "201401160000Z" -- January 16, 2014
|
|
DESCRIPTION
|
|
"remove rcsLoadBalOn(20) from cadSysSpOperMode."
|
|
REVISION "201311190000Z" -- November 19, 2013
|
|
DESCRIPTION
|
|
"Add operation mode for RCS load balancing control."
|
|
REVISION "201309060000Z" -- Sep 6, 2013
|
|
DESCRIPTION
|
|
"Add cadSysProcClearPolicingCounts."
|
|
REVISION "201308130000Z" -- August 13, 2013
|
|
DESCRIPTION
|
|
"Add support for LDP protocol throttling."
|
|
REVISION "201307220000Z" -- July 22, 2013
|
|
DESCRIPTION
|
|
"Add an additional reload status value for patch apply"
|
|
REVISION "201307100000Z" -- July 10, 2013
|
|
DESCRIPTION
|
|
"Removed factoryDCAMTestOff(7) from cadSysSpOperMode"
|
|
REVISION "201307010000Z" -- July 1, 2013
|
|
DESCRIPTION
|
|
"Add patch apply support."
|
|
REVISION "201306210000Z" -- June 21, 2013
|
|
DESCRIPTION
|
|
"Add support for reduced TCS generation."
|
|
REVISION "201306200000Z" -- June 20, 2013
|
|
DESCRIPTION
|
|
"Add cadSys1x1onCmAcPwrLossEnabled."
|
|
REVISION "201306190000Z" -- Jun 19, 2013
|
|
DESCRIPTION
|
|
"Add NPU Host Event throttling rate into CadSysProcPolicingConfig and related counts into CadSysProcPolicingCounts."
|
|
REVISION "201305150000Z" -- May 5, 2013
|
|
DESCRIPTION
|
|
"Add cadSysMICSecondarySecretTable."
|
|
REVISION "201301080000Z" -- January 8, 2013
|
|
DESCRIPTION
|
|
"Add patching operation support."
|
|
REVISION "201212030000Z" -- Dec 3, 2012
|
|
DESCRIPTION
|
|
"Remove fiveTapPtsOff(20) from cadSysSpOperMode."
|
|
REVISION "201211300000Z" -- Nov 30, 2012
|
|
DESCRIPTION
|
|
"Rename object names in cadLaesMdTimestampModeTable"
|
|
REVISION "201211150000Z" -- Oct 15, 2012
|
|
DESCRIPTION
|
|
"Add loadBalUnbondedVoipOn(6) and factoryDCAMTestOff(7) to cadSysSpOperMode"
|
|
REVISION "201210040000Z" -- Oct 4, 2012
|
|
DESCRIPTION
|
|
"Remove cadSysDownChannelAnnex"
|
|
REVISION "201210010000Z" -- Oct 1, 2012
|
|
DESCRIPTION
|
|
"Add cadLaesMdTimestampModeTable"
|
|
REVISION "201206150000Z" -- June 15, 2012
|
|
DESCRIPTION
|
|
"remove CadSysSourceInterface table and
|
|
remove cadSnmpSourceIpAddrType and
|
|
cadSnmpSourceIpAddr"
|
|
REVISION "201203220000Z" -- Mar 22, 2012
|
|
DESCRIPTION
|
|
"Add port licensing control."
|
|
REVISION "201203040000Z" -- Mar 4, 2012
|
|
DESCRIPTION
|
|
"Add new reload status values for standby firmware upgrade and standby write mem."
|
|
REVISION "201202230000Z" -- Feb 23, 2012
|
|
DESCRIPTION
|
|
"Add cadSysSourceAddressTable"
|
|
REVISION "201202080000Z" -- February 9, 2012
|
|
DESCRIPTION
|
|
"Add support for enhanced SNR with new TAPs."
|
|
REVISION "201201180000Z" -- Jan 18, 2012
|
|
DESCRIPTION
|
|
"Add new reload status value for image copy."
|
|
REVISION "201112130000Z" -- Dec 13, 2011
|
|
DESCRIPTION
|
|
"Add new reload status value."
|
|
REVISION "201111170000Z" -- Nov 17, 2011
|
|
DESCRIPTION
|
|
"Add new reload status values."
|
|
REVISION "201111080000Z" -- Nov 8, 2011
|
|
DESCRIPTION
|
|
"Removed upstreamLockupIgnore and upstreamLockupDetectLong.
|
|
Add support for maintenance lockup detection configuration."
|
|
REVISION "201111040000Z" -- Nov 4, 2011
|
|
DESCRIPTION
|
|
"Remove the following MIB objects:
|
|
cadSysProcScmGlobalPacketRate ,cadSysProcScmGlobalPacketsReceivedPassed,
|
|
cadSysProcScmGlobalPacketsReceivedDropped,cadSysProcOspfv3PacketsSent,
|
|
cadSysProcTftpIpv6PacketsSent,cadSysProcRouterControlGlobalPacketsSent,
|
|
cadSysProcArpPacketsSent, cadSysProcDhcpPacketsSent,
|
|
cadSysProcIcmpPacketsSent, cadSysProcOspfPacketsSent,
|
|
cadSysProcRipPacketsSent, cadSysProcIgmpPacketsSent,
|
|
cadSysProcRouterControlOtherPacketsSent, cadSysProcSnmpPacketsSent,
|
|
cadSysProcTftpPacketsSent, cadSysProcIsisPacketsSent,
|
|
cadSysProcScmGlobalPacketsSent, cadSysProcNdPacketsSent,
|
|
cadSysProcDhcpIpv6PacketsSent, cadSysProcIcmpIpv6PacketsSent,
|
|
cadSysProcMldPacketsSent, cadSysProcBgpPacketsSent,
|
|
cadSysProcPimPacketsSent, cadSysProcSnmpCmPacketsSent,
|
|
cadSysProcCopsPacketsSent, and cadSysProcTelnetPacketsSent."
|
|
REVISION "201107080000Z" -- July 8, 2011
|
|
DESCRIPTION
|
|
"Add support for maintenance control of fan speed."
|
|
REVISION "201105220000Z" -- May 22, 2011
|
|
DESCRIPTION
|
|
"Add support for maintenance overload configuration."
|
|
REVISION "201104050000Z" -- Apr 5, 2011
|
|
DESCRIPTION
|
|
"Modified allowed values of cadSysReloadStatus."
|
|
REVISION "201103030000Z" -- March 3, 2011
|
|
DESCRIPTION
|
|
"Add cadSysTftpProxy
|
|
cadSysProcTftpIpv6PacketRate
|
|
cadSysProcTftpIpv6PacketsReceivedPassed
|
|
cadSysProcTftpIpv6PacketsReceivedDropped
|
|
cadSysProcTftpIpv6PacketsSent"
|
|
REVISION "201102230000Z" -- Feb 23, 2011
|
|
DESCRIPTION
|
|
"Add cpeNacksForceCmReset bit back to cadSysSpOperMode"
|
|
REVISION "201012220000Z" -- Dec 22, 2010
|
|
DESCRIPTION
|
|
"Change cadSysDataServerSnmpRefreshTime to be in seconds"
|
|
REVISION "201012100000Z" -- Dec 10, 2010
|
|
DESCRIPTION
|
|
"Deprecated upstreamLockupIgnore and upstreamLockupDetectLong
|
|
and cadSysModemLossThreshold"
|
|
REVISION "201012010000Z" -- Dec 1, 2010
|
|
DESCRIPTION
|
|
"Add cadSysSnmpReadAheadMax and cadSysSnmpRefreshTime"
|
|
REVISION "201011180000Z" -- Nov 18, 2010
|
|
DESCRIPTION
|
|
"Add cadSysMacMoveBlockedOnRcptDhcpPkt"
|
|
REVISION "201009220000Z" -- Sep 22, 2010
|
|
DESCRIPTION
|
|
"Add support for DataServer variables."
|
|
REVISION "201009150000Z" -- Sep 15, 2010
|
|
DESCRIPTION
|
|
"Add pending(3), and none(4) to cadSysXDLicKeyStatus"
|
|
REVISION "201009020000Z" -- Sep 2, 2010
|
|
DESCRIPTION
|
|
"Add cadSysUnicastNpUsAcquisition"
|
|
REVISION "201007310000Z" -- July 31, 2010
|
|
DESCRIPTION
|
|
"Add support for OSPFv3 counts."
|
|
REVISION "201007210000Z" -- July 21, 2010
|
|
DESCRIPTION
|
|
"Remove cadSysAttrFlowAssignStrictEnforcement"
|
|
REVISION "201007120000Z" -- July 12, 2010
|
|
DESCRIPTION
|
|
"Add cadSysAttrFlowAssignStrictEnforcement"
|
|
REVISION "201003150000Z" -- Mar 15, 2010
|
|
DESCRIPTION
|
|
"Add cadSysAllowAmbiguityOverride"
|
|
REVISION "201002230000Z" -- Feb 23, 2010
|
|
DESCRIPTION
|
|
"Deprecate cadSysControlGroup"
|
|
REVISION "201002110000Z" -- Feb 11, 2010
|
|
DESCRIPTION
|
|
"Add reloadWritemem and reloadEraseMem to cadSysReloadOperation
|
|
and eraseMem and remoteEraseMem to cadSysReloadStatus"
|
|
REVISION "201001080000Z" -- Jan 8, 2010
|
|
DESCRIPTION
|
|
"Add cadSysPeakTrRateUpstream and cadCosUpPeakTrafficRate for Upstream
|
|
Power Boot feature. Make cadSysPeakTrafRateFor11CMs obsolete"
|
|
REVISION "200910080000Z" -- Oct 8, 2009
|
|
DESCRIPTION
|
|
"change default value of cadSysDelayedCpeLearning from false(2) to true(1)"
|
|
REVISION "200909220000Z" -- Sep 22, 2009
|
|
DESCRIPTION
|
|
"chagne default value of cadSysProcNdPacketRate from 1000 to 700"
|
|
REVISION "200909140000Z" -- Sep 14, 2009
|
|
DESCRIPTION
|
|
"Add cadSysSendTccRefIdPerFragment"
|
|
REVISION "200908170000Z" -- Aug 17, 2009
|
|
DESCRIPTION
|
|
"Add cadSysModPriDsInRccEnabled"
|
|
REVISION "200905040000Z" -- May 4, 2009
|
|
DESCRIPTION
|
|
"Add new cadSysSpOperMode use16ForDSPeakTrafficRate"
|
|
REVISION "200904220000Z" -- Apr 22, 2009
|
|
DESCRIPTION
|
|
"Added cadSysSourceIpAddrCableIntercept, cadSysSourceInterfaceCableIntercept
|
|
and cadSnmpSourceIpAddrTypeCableIntercept."
|
|
REVISION "200901230000Z" -- Jan 23, 2009
|
|
DESCRIPTION
|
|
"Added cadSysDelayedCpeLearning."
|
|
REVISION "200812180000Z" -- December 18, 2008
|
|
DESCRIPTION
|
|
"cadSysProcArpPacketRate default value changed from 2500 to 700"
|
|
REVISION "200812080000Z" -- December 8, 2008
|
|
DESCRIPTION
|
|
"Add cadMtcmConditionalOverride."
|
|
REVISION "200810220000Z" -- October 22, 2008
|
|
DESCRIPTION
|
|
"Add cadSysLO1LeakDetect control for DMM LO1 spurs."
|
|
REVISION "200809240000Z" -- Sep 24, 2008
|
|
DESCRIPTION
|
|
"Add cadSysProcCopsPacketRate and cadSysProcTelnetPacketRate."
|
|
REVISION "200809150000Z" -- Sep 15, 2008
|
|
DESCRIPTION
|
|
"Change default value of cadSysProcSnmpPacketRate from 100 to 650."
|
|
REVISION "200808280000Z" -- Aug 28, 2008
|
|
DESCRIPTION
|
|
"Add cadSysMaxUcdBurstLength."
|
|
REVISION "200803170000Z" -- March 17, 2008
|
|
DESCRIPTION
|
|
"Add oper mode bit for policy TLV and protocol throttling for IPV6."
|
|
REVISION "200802190000Z" -- Feb 19, 2008
|
|
DESCRIPTION
|
|
"Modified allowed values of cadSysReloadStatus."
|
|
REVISION "200802040000Z" -- Feb 4, 2008
|
|
DESCRIPTION
|
|
"Added cadSysDownChannelAnnex. Annex is configured per CMTS bassis."
|
|
REVISION "200712020000Z" -- December 2, 2007
|
|
DESCRIPTION
|
|
"Added additional reload support"
|
|
REVISION "200611090000Z" -- November 9, 2006
|
|
DESCRIPTION
|
|
"Add oneDCmDSMaxTrafBurstOn to operation mode."
|
|
REVISION "200608290000Z" -- August 29, 2006
|
|
DESCRIPTION
|
|
"Add cadSysSourceInterfaceRemoteQuery to cadSysSourceInterface Object."
|
|
REVISION "200608100000Z" -- August 10, 2006
|
|
DESCRIPTION
|
|
"Add bpiHybridOff to cadSysSpOperMode object."
|
|
REVISION "200607120000Z"
|
|
DESCRIPTION
|
|
"Added SNMP remote engine support."
|
|
REVISION "200602220000Z"
|
|
DESCRIPTION
|
|
"Removed cpeNacksForceCmReset bit from cadSysSpOperMode"
|
|
REVISION "200601250000Z"
|
|
DESCRIPTION
|
|
"Added upstreamLockupDetectLong BIT to cadSysSpOperMode for longer upstream lockup detect sampling period."
|
|
REVISION "200601120000Z"
|
|
DESCRIPTION
|
|
"Added cadSysMtceParams for maintenance intervals and scheduling."
|
|
REVISION "200601030000Z"
|
|
DESCRIPTION
|
|
"Added cadSysCpeHostAuthorization for CPE Host Authorization (Motorola Style Anti-Spoofing) feature."
|
|
REVISION "200509230000Z"
|
|
DESCRIPTION
|
|
"Added cadSnmpSourceIp for Legal Intercept feature."
|
|
REVISION "200509210000Z"
|
|
DESCRIPTION
|
|
"Add support for suppressing downstream priority channel mapping
|
|
add support for virtual modems."
|
|
REVISION "200508300000Z"
|
|
DESCRIPTION
|
|
"Add support for disabling downstream override and supressing DCDs."
|
|
REVISION "200508240000Z"
|
|
DESCRIPTION
|
|
"Added cadSysPeakTrafRateFor11CMs."
|
|
REVISION "200508080000Z"
|
|
DESCRIPTION
|
|
"Add support for DOCSIS 1.0+"
|
|
REVISION "200507110000Z"
|
|
DESCRIPTION
|
|
"Added cadCosDnPeakTrafficRate for Traffic Shaping for 2D12U feature."
|
|
REVISION "200506200000Z"
|
|
DESCRIPTION
|
|
"Renamed showCmFormatCV bit to showCmFormatCVOff and flipped the semantics"
|
|
REVISION "200506080000Z"
|
|
DESCRIPTION
|
|
"Added SCM Global counts"
|
|
REVISION "200505180000Z"
|
|
DESCRIPTION
|
|
"Added bpiDynamicMulticastOff bit to cadSysSpOperMode"
|
|
REVISION "200504210000Z"
|
|
DESCRIPTION
|
|
"Added showCmFormatCV bit to cadSysSpOperMode"
|
|
REVISION "200504140000Z"
|
|
DESCRIPTION
|
|
"Merge with 4.6"
|
|
REVISION "200503010000Z"
|
|
DESCRIPTION
|
|
"Remove obsolete error recovery bits"
|
|
REVISION "200501060000Z"
|
|
DESCRIPTION
|
|
"Included support for Source Interface for SNMP Traps."
|
|
REVISION "200412030000Z"
|
|
DESCRIPTION
|
|
"Included support for TFTP Enforce feature."
|
|
REVISION "200410120000Z"
|
|
DESCRIPTION
|
|
"Included support for SNMP policing on the FCM."
|
|
REVISION "200409220000Z"
|
|
DESCRIPTION
|
|
"Included cadSysTcpSmoothingValue1D8U and cadSysTcpSmoothingValue2D12U in the cadSysParamsGroup."
|
|
REVISION "200404300000Z"
|
|
DESCRIPTION
|
|
"Added IS-IS counts."
|
|
REVISION "200404130000Z"
|
|
DESCRIPTION
|
|
"Included cadSysRemoteFSEnable and cadSysRemotePortEnable in the cadSysParamsGroup."
|
|
REVISION "200403230000Z"
|
|
DESCRIPTION
|
|
"Added cadSysRemoteFSEnable and cadSysRemotePortEnable for allowing
|
|
the active SCM to access filesystems and ports of the standby SCM."
|
|
REVISION "200402230000Z"
|
|
DESCRIPTION
|
|
"Added cadSysFlaplistPowerAdjustThreshold for FlapManager enhancement."
|
|
REVISION "200402200000Z"
|
|
DESCRIPTION
|
|
"Add automatic fan control switch to sysparams."
|
|
REVISION "200312050000Z"
|
|
DESCRIPTION
|
|
"Change default FCM other protocol policing rate for BGP."
|
|
REVISION "200310280000Z"
|
|
DESCRIPTION
|
|
"Removed mapgbdiff, mapgbsm1, mapgbsm2, ptcspec, and preeq10 from cadSysSpOperMode object."
|
|
REVISION "200310210000Z"
|
|
DESCRIPTION
|
|
"Changed cadCosToQosMapping scalar object to a table."
|
|
REVISION "200310200000Z"
|
|
DESCRIPTION
|
|
"Changed bootparams to rw."
|
|
REVISION "200308260000Z"
|
|
DESCRIPTION
|
|
"Added default maximum traffic burst for 1.1 CMs."
|
|
REVISION "200308250000Z"
|
|
DESCRIPTION
|
|
"Added percent additional downstream bandwidth allocated for dynamic service flows."
|
|
REVISION "200308180000Z"
|
|
DESCRIPTION
|
|
"Change default FCM policing default rates"
|
|
REVISION "200308060000Z"
|
|
DESCRIPTION
|
|
"Added upce bit to cadSysSpOperMode"
|
|
REVISION "200306160000Z"
|
|
DESCRIPTION
|
|
"Added cpeNacksForceCmReset bit to cadSysSpOperMode"
|
|
REVISION "200305230000Z"
|
|
DESCRIPTION
|
|
"Changed default of cadSysMaxQoSActiveTimeout from 0 to 30"
|
|
REVISION "200305080000Z"
|
|
DESCRIPTION
|
|
"Add server enable/disable support."
|
|
REVISION "200304300000Z"
|
|
DESCRIPTION
|
|
"Add both front panel addresses to bootparams."
|
|
REVISION "200304200000Z"
|
|
DESCRIPTION
|
|
"Changed maximum size of MIC authstring to 64 bytes."
|
|
REVISION "200304140000Z"
|
|
DESCRIPTION
|
|
"Added cmstatusoperational bit to cadSysSpOperMode object."
|
|
REVISION "200303200000Z"
|
|
DESCRIPTION
|
|
"Added ability to provision whether a CM in 1.0 can use concat and/or frag"
|
|
REVISION "200303140000Z"
|
|
DESCRIPTION
|
|
"Added maximum allowed QoS Active and Admitted Timeout values"
|
|
REVISION "200303070000Z"
|
|
DESCRIPTION
|
|
"Change length of MIC auth string"
|
|
REVISION "200302140000Z"
|
|
DESCRIPTION
|
|
"Added tables to support banner related objects.
|
|
Change encoding of MIC auth string"
|
|
REVISION "200212120000Z"
|
|
DESCRIPTION
|
|
"Removed special operating mode for preeq."
|
|
REVISION "200211220000Z"
|
|
DESCRIPTION
|
|
"Added control object for erasing NVRAM."
|
|
REVISION "200211200000Z"
|
|
DESCRIPTION
|
|
"Add processor protocol policing objects."
|
|
REVISION "200210040000Z"
|
|
DESCRIPTION
|
|
"Added special operating mode for preeq."
|
|
REVISION "200210030000Z"
|
|
DESCRIPTION
|
|
"Changed cadCosUpMaxTrafficBurst from 1522 to 3044, per RFI-N-02091."
|
|
REVISION "200207020000Z"
|
|
DESCRIPTION
|
|
"Changed cadSysCMConfiguration to read-write."
|
|
REVISION "200204250000Z"
|
|
DESCRIPTION
|
|
"Add key chain objects."
|
|
REVISION "200204230000Z"
|
|
DESCRIPTION
|
|
"Add enbudptcpfltr bit to cadSysSpOperMode object."
|
|
REVISION "200204220000Z"
|
|
DESCRIPTION
|
|
"Add global counts collection rate object."
|
|
REVISION "200204020001Z"
|
|
DESCRIPTION
|
|
"Add cadSysSpOperMode object."
|
|
REVISION "200204020000Z"
|
|
DESCRIPTION
|
|
"Add cosToQosMapping group."
|
|
REVISION "200201150000Z"
|
|
DESCRIPTION
|
|
"Add configuration save time."
|
|
REVISION "200111070000Z"
|
|
DESCRIPTION
|
|
"Add floating IP address and remove NAM support."
|
|
REVISION "200108180000Z"
|
|
DESCRIPTION
|
|
"Add system table dictionary."
|
|
REVISION "200107180000Z"
|
|
DESCRIPTION
|
|
"Add enable/disable for Mcard ports."
|
|
|
|
::= { cadSystem 1 }
|
|
|
|
--=========== System Objects ==============================
|
|
cadSysParams OBJECT IDENTIFIER ::= { cadSystemMib 1 }
|
|
cadSysSystem OBJECT IDENTIFIER ::= { cadSystemMib 2 }
|
|
cadSysControl OBJECT IDENTIFIER ::= { cadSystemMib 3 }
|
|
cadSysSnmp OBJECT IDENTIFIER ::= { cadSystemMib 4 }
|
|
cadSysBootParams OBJECT IDENTIFIER ::= { cadSystemMib 5 }
|
|
cadSysReload OBJECT IDENTIFIER ::= { cadSystemMib 6 }
|
|
cadSysImage OBJECT IDENTIFIER ::= { cadSystemMib 7 }
|
|
cadSysDictionary OBJECT IDENTIFIER ::= { cadSystemMib 8 }
|
|
cadSysConfiguration OBJECT IDENTIFIER ::= { cadSystemMib 9 }
|
|
cadCosToQosMapping OBJECT IDENTIFIER ::= { cadSystemMib 10 }
|
|
cadSysKeyChain OBJECT IDENTIFIER ::= { cadSystemMib 11 }
|
|
cadSysProcPolicingConfig OBJECT IDENTIFIER ::= { cadSystemMib 13 }
|
|
cadSysProcPolicingCounts OBJECT IDENTIFIER ::= { cadSystemMib 14 }
|
|
cadSysBanner OBJECT IDENTIFIER ::= { cadSystemMib 15 }
|
|
cadSysServer OBJECT IDENTIFIER ::= { cadSystemMib 16 }
|
|
cadSysPatchParams OBJECT IDENTIFIER ::= { cadSystemMib 17 }
|
|
cadSysMtceParams OBJECT IDENTIFIER ::= { cadSystemMib 19 }
|
|
cadSysDataServer OBJECT IDENTIFIER ::= { cadSystemMib 21 }
|
|
cadSysSourceAddress OBJECT IDENTIFIER ::= { cadSystemMib 22 }
|
|
cadSysLicenseControl OBJECT IDENTIFIER ::= { cadSystemMib 23 }
|
|
cadLaesMdTimestampMode OBJECT IDENTIFIER ::= { cadSystemMib 24 }
|
|
cadSysSharedSecret OBJECT IDENTIFIER ::= { cadSystemMib 25 }
|
|
|
|
--=========== Params Objects ==============================
|
|
|
|
cadSysSyncInterval OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "Milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Nominal time between transmission of SYNC messages. (ref 6.3.2)"
|
|
::= { cadSysParams 1 }
|
|
|
|
cadSysUCDInterval OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2000)
|
|
UNITS "Milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time between transmission of UCD messages. (ref 6.3.3)"
|
|
::= { cadSysParams 2 }
|
|
|
|
cadSysMaxMAPPending OBJECT-TYPE
|
|
SYNTAX Integer32 (0..4096)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of mini-slots that a CMTS is allowed to map
|
|
into the future. (ref 6.3.4)"
|
|
::= { cadSysParams 3 }
|
|
|
|
cadSysRangingInterval OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2000)
|
|
UNITS "Milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time between transmission of broadcast Ranging requests. (ref 7.3.3)"
|
|
::= { cadSysParams 4 }
|
|
|
|
cadSysInvitedRangingRetries OBJECT-TYPE
|
|
SYNTAX Integer32 (16)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of retries on inviting ranging requests. (ref 9.2.4)"
|
|
::= { cadSysParams 5 }
|
|
|
|
cadSysRegistrationRequestRetries OBJECT-TYPE
|
|
SYNTAX Integer32 (3)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of retries on registration requests/responses."
|
|
::= { cadSysParams 6 }
|
|
|
|
cadSysCMMAPProcessingTime OBJECT-TYPE
|
|
SYNTAX Integer32 (200..2000)
|
|
UNITS "Microseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time provided between arrival of the last bit of a MAP
|
|
at a CM and effectiveness of that MAP. (ref 7.1.1)"
|
|
::= { cadSysParams 7 }
|
|
|
|
cadSysCMRangingResponseProcessingTime OBJECT-TYPE
|
|
SYNTAX Integer32 (1..200)
|
|
UNITS "Milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum tile allowed fro a CM following receipt of a rangin
|
|
response before it is expected to reply to an invited ranging
|
|
request."
|
|
::= { cadSysParams 8 }
|
|
|
|
cadSysCMConfiguration OBJECT-TYPE
|
|
SYNTAX Integer32 (30..2000)
|
|
UNITS "Seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum time allowed for a CM, following receipt of a
|
|
configuration file, to send a Registration Request to a CMTS."
|
|
DEFVAL { 30 }
|
|
::= { cadSysParams 9 }
|
|
|
|
cadSysT5Timeout OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2000)
|
|
UNITS "Milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Wait for Upstream CHannel Change response."
|
|
::= { cadSysParams 10 }
|
|
|
|
cadSysT6Timeout OBJECT-TYPE
|
|
SYNTAX Integer32 (0..3000)
|
|
UNITS "Milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Wait for REG-RSP and REG-ACK"
|
|
::= { cadSysParams 11 }
|
|
|
|
cadSysMiniSlotSize OBJECT-TYPE
|
|
SYNTAX Integer32 (32..300)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Size of mini-slotfor upstream transmission. Must be a
|
|
power of 2 (in units of the Timebase Tick)."
|
|
::= { cadSysParams 12 }
|
|
|
|
cadSysDSxRequestRetries OBJECT-TYPE
|
|
SYNTAX Integer32 (3)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of Timeout Retries on DSA/DSC/DSD Requests."
|
|
::= { cadSysParams 13 }
|
|
|
|
cadSysDSxResponseRetries OBJECT-TYPE
|
|
SYNTAX Integer32 (3)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of Timeout Retries on DSA/DSC/DSD Responses."
|
|
::= { cadSysParams 14 }
|
|
|
|
cadSysT7Timeout OBJECT-TYPE
|
|
SYNTAX Integer32 (0..1000)
|
|
UNITS "Milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Wait for DSA/DSC/DSD Response timeout."
|
|
::= { cadSysParams 15 }
|
|
|
|
cadSysT8Timeout OBJECT-TYPE
|
|
SYNTAX Integer32 (0..300)
|
|
UNITS "Milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Wait for DSA/DSC/DSD Acknowledge timeout."
|
|
::= { cadSysParams 16 }
|
|
|
|
cadSysT9Timeout OBJECT-TYPE
|
|
SYNTAX Integer32 (15..1500)
|
|
UNITS "Minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Registration timeout, the time allowed between the CMTS
|
|
sending a RNG-RSP(success) to a CM, and receiving a
|
|
REG-REQ from that same CM."
|
|
::= { cadSysParams 17 }
|
|
|
|
cadSysT10Timeout OBJECT-TYPE
|
|
SYNTAX Integer32 (0..3000)
|
|
UNITS "Milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Wait for Transaction End timeout."
|
|
::= { cadSysParams 18 }
|
|
|
|
cadSysT11Timeout OBJECT-TYPE
|
|
SYNTAX Integer32 (0..300)
|
|
UNITS "Milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Wait for a DCC Response on the old channel."
|
|
::= { cadSysParams 19 }
|
|
|
|
cadSysT13Timeout OBJECT-TYPE
|
|
SYNTAX Integer32 (0..1000)
|
|
UNITS "Milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum holding time for QOS resources for DCC."
|
|
::= { cadSysParams 20 }
|
|
|
|
cadSysDCCREQRetries OBJECT-TYPE
|
|
SYNTAX Integer32 (3)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of retries on Dynamic Channel Change Request."
|
|
::= { cadSysParams 21 }
|
|
|
|
cadSysMICEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable MIC checking on the CMTS."
|
|
::= { cadSysParams 22 }
|
|
|
|
cadSysMICAuthString OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..64))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Encrypted MIC Authentication"
|
|
::= { cadSysParams 23 }
|
|
|
|
cadSysAutoRecoveryEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable automatic recovery of card/port/software in case
|
|
of component failure."
|
|
DEFVAL { true }
|
|
::= { cadSysParams 24 }
|
|
|
|
cadSysActiveIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ip Address of the active control complex."
|
|
DEFVAL { '00000000'h }
|
|
::= { cadSysParams 25 }
|
|
|
|
cadSysSpOperMode OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
dqossf10cms(0),
|
|
adjrxpwrctl(1),
|
|
enbudptcpfltr(2),
|
|
upce(3),
|
|
use16ForDSPeakTrafficRate(4),
|
|
cpeNacksForceCmReset(5),
|
|
loadBalUnbondedVoipOn(6),
|
|
upDownTrapIfDescrOff(7),
|
|
ofdmSparingCleanupOff(8),
|
|
limitUsRngRspFreqOff(9),
|
|
reserved10(10),
|
|
cmstatusoperational(11),
|
|
reserved12(12),
|
|
docsis20test(13),
|
|
reserved14(14),
|
|
reserved15(15),
|
|
reserved16(16),
|
|
reserved17(17),
|
|
reserved18(18),
|
|
reserved19(19),
|
|
reserved20(20),
|
|
showCmFormatCVOff(21),
|
|
bpiDynamicMulticastOff(22),
|
|
docsis10plusOff(23),
|
|
downstreamOverrideOn(24),
|
|
supressDCDOff(25),
|
|
virtualCmOff(26),
|
|
bpiHybridOff(27),
|
|
oneDCmDSMaxTrafBurstOn(28),
|
|
docsis30ReqTxPolicyChkOff(29),
|
|
reserved30(30),
|
|
reserved31(31)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Special operational mode. Value of 1 indicates the mode is enabled.
|
|
dqossf10cms - Allow 1.0 CMs to be stored in DocsQosServiceFlowEntry
|
|
adjrxpwrctl - Allow rx power control to be adjusted by mod type usage
|
|
enbudptcpfltr - Allow combining of Udp and Tcp messages in a single filter
|
|
upce - Allow Upstream Packet Classifier Enforcement
|
|
use16ForDSPeakTrafficRate - use the defunct TLV type 16 for DS peak traffic rate
|
|
cpeNacksForceCmReset - - Force CM reset upon receiving 3 consecutive CPE NACKs
|
|
loadBalUnbondedVoipOn - Allow load balancing for non-bonded voice calls
|
|
limitUsRngRspFreqOff - Prevent CM from using an upstream frequency beyond 42 MHz
|
|
upDownTrapIfDescrOff - Allow linkup or linkdown trap to include ifDescr
|
|
ofdmSparingCleanupOff - Allow automatically reset any D3.1 CMs in a cable-mac that
|
|
has an OFDM channel on that DCAM in the CM's RCS after a
|
|
failover or fallback
|
|
cmstatusoperational - Support DOCS-IF-MIB draft-05 (cw26)'s change to
|
|
docsIfCmtsCmStatusValue, such that online modems take on a value of
|
|
operational(8) at the CMTS. If disabled, operational(8) is not used and
|
|
online modems take on a value of registrationComplete(6) at the CMTS.
|
|
docsis20test - Allow running of DOCSIS 2.0 Tests.
|
|
showCmFormatCVOff - show cable modem is formatted per CableVision's requirements if set to 0.
|
|
docsis10plusOff - DOCSIS 1.0+ support is enabled if set to 0.
|
|
downstreamOverrideOn - downstream overrides are disabled if this is set to 0.
|
|
supressDCDOff - DCDs are suppressed if set to 0.
|
|
virtualCmOff - support for virtual modems is enabled if set to 0.
|
|
bpiHybridOff - Allow DOCSIS 1.1 modems to operate in BPI instead of BPI+ if this is set to 0.
|
|
oneDCmDSMaxTrafBurstOn - Override Max Traffic Burst for DOCSIS 1.1 modems on a 1D CAM with E6000 setting if this is set to 0.
|
|
docsis30ReqTxPolicyChkOff - Override DOCSIS 3.0 checking for Request/Transmission Policy TLV on upstream flows.
|
|
"
|
|
DEFVAL { { dqossf10cms, adjrxpwrctl, enbudptcpfltr, use16ForDSPeakTrafficRate, cpeNacksForceCmReset,
|
|
loadBalUnbondedVoipOn, upDownTrapIfDescrOff, ofdmSparingCleanupOff, limitUsRngRspFreqOff, reserved10,
|
|
cmstatusoperational, reserved12, reserved14,
|
|
reserved15, reserved16, reserved17,
|
|
reserved18, reserved19, reserved20, showCmFormatCVOff, bpiDynamicMulticastOff,
|
|
docsis10plusOff, downstreamOverrideOn, supressDCDOff, virtualCmOff, bpiHybridOff,
|
|
oneDCmDSMaxTrafBurstOn, docsis30ReqTxPolicyChkOff, reserved30, reserved31
|
|
} } -- upce and docsis20test disabled and use16ForDSPeakTrafficRate by default
|
|
::= { cadSysParams 26 }
|
|
|
|
cadSysCountsCollectionRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0|15..1440) -- disabled or from 15 minutes to 24 hours
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The period, in minutes, in which every count in the CMTS
|
|
is to be collected. If this object is set to 0, counts
|
|
collection will be disabled."
|
|
DEFVAL { 120 } -- 2 hours
|
|
::= { cadSysParams 27 }
|
|
|
|
cadSysMaxQoSActiveTimeout OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the maximum QoS Active Timeout the E6000 is willing to allow. If
|
|
a larger value is received in a CM request the E6000 will return this value
|
|
instead in the response (Reference DOCSIS RFI Section c.2.2.5.6). Note a
|
|
value of 0 is infinite and is therefore treated as the largest value in the
|
|
range."
|
|
DEFVAL { 30 }
|
|
::= { cadSysParams 28 }
|
|
|
|
cadSysMaxQoSAdmittedTimeout OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the maximum QoS Admitted Timeout the E6000 is willing to allow. If
|
|
a larger value is received in a CM request the E6000 will return this value
|
|
instead in the response (Reference DOCSIS RFI Section c.2.2.5.7). Note a
|
|
value of 0 is infinite and is therefore treated as the largest value in the
|
|
range."
|
|
DEFVAL { 200 }
|
|
::= { cadSysParams 29 }
|
|
|
|
cadSysAllow10CmConcatenation OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines whether or not the E6000 will allow a modem operating in DOCSIS 1.0
|
|
mode to utilize concatenation. If this value is false and a modem operating
|
|
in 1.0 mode sends up a modem capability indicating concatenation the E6000 will
|
|
respond by turning that capability off. If this value is true the modem will
|
|
be returned whatever it requests (on or off)."
|
|
DEFVAL { false }
|
|
::= { cadSysParams 30 }
|
|
|
|
cadSysAllow10CmFragmentation OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines whether or not the E6000 will allow a modem operating in DOCSIS 1.0
|
|
mode to utilize fragmentation. If this value is false and a modem operating
|
|
in 1.0 mode sends up a modem capability indicating fragmentation the E6000 will
|
|
respond by turning that capability off. If this value is true the modem will
|
|
be returned whatever it requests (on or off)."
|
|
DEFVAL { true }
|
|
::= { cadSysParams 31 }
|
|
|
|
cadSysPercentAddtlDsBwAllocated OBJECT-TYPE
|
|
SYNTAX Integer32 (0..5)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value of this setting is used to make a percentage increase to a dynamic
|
|
downstream service flows maximum traffic rate. This is flexiblity actually
|
|
causes the E6000 to operate outside the DOCSIS 1.1 specification by allocating and
|
|
allowing more traffic than was actually requested. The initial reason for
|
|
providing this capability is to mask problems produced in the Voice environment
|
|
where devices have been seen to violate the traffic rates. Examples of this are
|
|
MTAs that overuse the QI bit for long durations thus overdriving the downstream
|
|
burst interval and the Neura IPDT gateway introducing an additional 0.5% inband
|
|
signaling to the DS voice flow"
|
|
DEFVAL { 1 }
|
|
::= { cadSysParams 32 }
|
|
|
|
cadSysMaxTrafBurstFor11CMs OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the default value that will be used to populate the Maximum Traffic Burst
|
|
for a 1.1 modem unless the maximum traffic burst TLV is explicitly provided in either
|
|
the modems Request or in a Service Class Name definition. This value is being made
|
|
programmable for 2 reasons: 1) So that it can be set to the DOCSIS default of 3044 for
|
|
CableLabs testing and 2) it can be tuned for real world applications."
|
|
DEFVAL { 128000 }
|
|
::= { cadSysParams 33 }
|
|
|
|
cadSysFanSpeedControlEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Enable automatic fan speed control. "
|
|
DEFVAL { false }
|
|
::= { cadSysParams 34 }
|
|
|
|
cadSysFlaplistPowerAdjustThreshold OBJECT-TYPE
|
|
SYNTAX TenthdB (0|10..100)
|
|
UNITS "dB"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The threshold is used to monitor the power adjust in the flap
|
|
list. For a range request received that results in a power adjust
|
|
exceeding the threshold value will cause the counter
|
|
cadIfCmtsCmCountsPowerAdjExceedsThreshold to be incremented.
|
|
If the threshold is set to 0, the monitoring of power adjustment
|
|
in the flap list is disabled."
|
|
DEFVAL { 30 }
|
|
::= { cadSysParams 35 }
|
|
|
|
cadSysRemoteFSEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the active SCM should allow mounting the
|
|
the filesystems of the standby SCM."
|
|
DEFVAL { true }
|
|
::= { cadSysParams 36 }
|
|
|
|
cadSysRemotePortEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the active SCM should allow redirection of
|
|
the serial console of the standby SCM."
|
|
DEFVAL { true }
|
|
::= { cadSysParams 37 }
|
|
|
|
cadSysTcpSmoothingValue1D8U OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCP smoothing value to be programmed into hardware on 1D8U CAMs."
|
|
DEFVAL { 0 }
|
|
::= { cadSysParams 38 }
|
|
|
|
cadSysTcpSmoothingValue2D12U OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCP smoothing value to be programmed into hardware on 2D12U CAMs."
|
|
DEFVAL { 0 }
|
|
::= { cadSysParams 39 }
|
|
|
|
cadSysModemLossThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32 (10..2000)
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Minimum modem threshold triggering detection of an
|
|
upstream channel lockup."
|
|
DEFVAL { 10 }
|
|
::= { cadSysParams 40 }
|
|
|
|
cadSysPeakTrafRateFor11CMs OBJECT-TYPE
|
|
SYNTAX BitRate
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"This is the default value that will be used to populate the Peak Traffic Rate
|
|
for a 1.1 modem configuration file unless the peak traffic rate is explicitly
|
|
provided by a Service Class Name definition."
|
|
DEFVAL { 0 }
|
|
::= { cadSysParams 41 }
|
|
|
|
|
|
cadSysCpeHostAuthorization OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable enables the CPE Host Authorization feature."
|
|
DEFVAL { false }
|
|
::= { cadSysParams 44 }
|
|
|
|
cadSysMaxUcdBurstLength OBJECT-TYPE
|
|
SYNTAX Integer32(2048..16128)
|
|
UNITS "bytes"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable limits the maximum UCD burst length."
|
|
DEFVAL { 16128 }
|
|
::= { cadSysParams 46 }
|
|
|
|
cadSysLO1LeakDetect OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable controls LO1 leak detection on the DMM."
|
|
DEFVAL { false }
|
|
::= { cadSysParams 47 }
|
|
|
|
cadMtcmConditionalOverride OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If set to 'true', for a MAC Domain configured for MTCM enabled operation,
|
|
the E6000 will set a registering MTCM-capable CM to be MTCM disabled (via REG-RSP message)
|
|
unless at least one of the config file's service flows was specifically configured
|
|
to have the Bonded bit set in the Required attribute mask
|
|
(in which case the CM will be set to MTCM enabled).
|
|
If set to false, standard DOCSIS 3.0 operation will result."
|
|
DEFVAL { false }
|
|
::= { cadSysParams 48 }
|
|
|
|
cadSysDelayedCpeLearning OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This setting only applies to modems that have BPI enabled.
|
|
When set to false(2), CPE learning is enabled during registration
|
|
when BPI initialization is initiated for those modems using BPI.
|
|
When set to true(1), CPE learning is delayed during registration
|
|
until BPI initialization is complete for those modems using BPI.
|
|
For modems not using BPI, CPE learning is enabled when registration is complete."
|
|
DEFVAL { true }
|
|
::= { cadSysParams 49 }
|
|
|
|
cadSysModPriDsInRccEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable modifying primary Downstream channel in RCC of Reg-Rsp-MP.
|
|
Refer ECN 690."
|
|
DEFVAL { false }
|
|
::= { cadSysParams 52 }
|
|
|
|
cadSysSendTccRefIdPerFragment OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Settings for sending the Transmit Channel Configuration (TCC) Reference sub-type 46.1 for type 46 TCC fragmentation.
|
|
If 'true', sends 46.1 Ref ID in every type 46 TCC fragment;
|
|
If 'false', only sends 46.1 Ref ID in the first TCC fragment (DOCSIS Compliant)."
|
|
DEFVAL { true }
|
|
::= { cadSysParams 53 }
|
|
|
|
cadSysPeakTrRateUpstream OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables support for Peak Traffic Rate in the upstream direction."
|
|
DEFVAL { false }
|
|
::= { cadSysParams 54 }
|
|
|
|
cadSysAllowAmbiguityOverride OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables ambiguity resolution channel-override actions."
|
|
DEFVAL { false }
|
|
::= { cadSysParams 55 }
|
|
|
|
cadSysUnicastNpUsAcquisition OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables unicast non-primary upstream channel acquisition."
|
|
DEFVAL { false }
|
|
::= { cadSysParams 56}
|
|
|
|
cadSysMacMoveBlockedOnRcptDhcpPkt OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MAC movement is blocked on receipt of DHCP packets"
|
|
DEFVAL { true }
|
|
::= { cadSysParams 57 }
|
|
|
|
cadSysTftpProxy OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1),
|
|
ipv4only(2),
|
|
ipv6only(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter provides a global enable for the TFTP
|
|
Enforce and Dynamic Shared Secret features. In order for
|
|
the cadIfMacDomainTftpEnforce and cadIfMacDomainDynamicSecret
|
|
parameters to take effect, this parameter must also be enabled.
|
|
This parameter can also limit those features to only IPv4
|
|
transfers or IPv6 transfers."
|
|
DEFVAL { enable }
|
|
::= { cadSysParams 58 }
|
|
|
|
cadSysFanSpeedLevel OBJECT-TYPE
|
|
SYNTAX Integer32(0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set the fan speed for the chassis."
|
|
DEFVAL { 0 }
|
|
::= { cadSysParams 59 }
|
|
|
|
cadSys1x1onCmAcPwrLossEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables/disables the CMTS reaction to a AC Power Loss CM-STATUS.
|
|
If true, the CMTS will wait until cadSys1x1onCmAcPwrLossHoldoff expires, and then
|
|
the CMTS will place the CM into a 1x1 (US/DS) channel mode to conserve CM battery power.
|
|
If false, the CMTS will not place a CM that reports an AC Power Loss into 1x1 mode."
|
|
DEFVAL { false }
|
|
::= { cadSysParams 60 }
|
|
|
|
cadSysFlapListInsertionThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (60..86400)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object shows the number of seconds between successive ranging
|
|
attempts that must pass before the modem is counted as flapped.
|
|
The modem must have also been in a provisioning or registered state
|
|
before the ranging request."
|
|
DEFVAL { 180 }
|
|
::= { cadSysParams 61 }
|
|
|
|
cadSysAES128Enable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables AES-128 Cryptography Suite for BPI+ when true."
|
|
DEFVAL { false }
|
|
::= { cadSysParams 62 }
|
|
|
|
--=========== System Objects ==============================
|
|
cadSysContact OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The textual identification of the contact person for this
|
|
managed node, together with information on how to contact
|
|
this person. If no contact information is known, the value
|
|
is the zero-length string."
|
|
DEFVAL { "support@arris.com" }
|
|
::= { cadSysSystem 1 }
|
|
|
|
cadSysName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An administratively-assigned name for this managed node.
|
|
By convention, this is the node's fully-qualified domain
|
|
name. If the name is unknown, the value is the zero-length
|
|
string."
|
|
::= { cadSysSystem 2 }
|
|
|
|
cadSysLocation OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The physical location of this node (e.g., `telephone
|
|
closet, 3rd floor'). If the location is unknown, the value
|
|
is the zero-length string."
|
|
DEFVAL { "" }
|
|
::= { cadSysSystem 3 }
|
|
|
|
--=========== Control Objects =============================
|
|
|
|
cadSysWriteMem OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable always returns FALSE upon reading. When
|
|
set to TRUE, the configuration data currently resident
|
|
in volatile memory (RAM) is written to persistent memory (NVRAM)."
|
|
DEFVAL { false }
|
|
::= { cadSysControl 1 }
|
|
|
|
cadSysEraseMem OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable always returns FALSE upon reading. When
|
|
set to TRUE, the configuration data currently resident
|
|
in persistent memory (NVRAM) is erased."
|
|
DEFVAL { false }
|
|
::= { cadSysControl 2 }
|
|
|
|
--=========== SNMP Objects =============================
|
|
|
|
cadSysEnableAuthenTraps OBJECT-TYPE
|
|
SYNTAX INTEGER { enable(1), disabled(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the SNMP entity is permitted to generate
|
|
authentication traps."
|
|
::= { cadSysSnmp 1 }
|
|
|
|
cadSysSnmpReadAheadMax OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..20)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is the maximum number of records to read ahead"
|
|
DEFVAL { 0 }
|
|
::= { cadSysSnmp 2 }
|
|
|
|
cadSysSnmpRefreshTime OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..1200)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value represents how old a database record can be to be used."
|
|
DEFVAL { 0 }
|
|
::= { cadSysSnmp 3 }
|
|
|
|
cadSnmpRemoteEngineTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadSnmpRemoteEngineEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Table containing information of remote SNMP engines."
|
|
::= { cadSysSnmp 4 }
|
|
|
|
cadSnmpRemoteEngineEntry OBJECT-TYPE
|
|
SYNTAX CadSnmpRemoteEngineEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry containing information of remote SNMP engines."
|
|
INDEX { cadSnmpRemoteEngineIpAddress, cadSnmpRemoteEnginePortNumber }
|
|
::= { cadSnmpRemoteEngineTable 1 }
|
|
|
|
CadSnmpRemoteEngineEntry ::= SEQUENCE {
|
|
cadSnmpRemoteEngineIpAddress IpAddress,
|
|
cadSnmpRemoteEnginePortNumber Integer32,
|
|
cadSnmpRemoteEngineID SnmpEngineID,
|
|
cadSnmpRemoteUserName SnmpAdminString,
|
|
cadSnmpRemoteEngineType INTEGER,
|
|
cadSnmpRemoteEngineStatus RowStatus
|
|
}
|
|
|
|
cadSnmpRemoteEngineIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP address of a remote SNMP engine with which this user can communicate."
|
|
::= { cadSnmpRemoteEngineEntry 1 }
|
|
|
|
cadSnmpRemoteEnginePortNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UDP port of a remote SNMP engine with which this user can communicate."
|
|
::= { cadSnmpRemoteEngineEntry 2 }
|
|
|
|
cadSnmpRemoteEngineID OBJECT-TYPE
|
|
SYNTAX SnmpEngineID
|
|
MAX-ACCESS read-create
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"An SNMP engine's administratively-unique identifier of a remote
|
|
SNMP engine with which this user can communicate."
|
|
::= { cadSnmpRemoteEngineEntry 3 }
|
|
|
|
cadSnmpRemoteUserName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE(1..32))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A human readable string representing the name of the user of a remote
|
|
SNMP engine."
|
|
::= { cadSnmpRemoteEngineEntry 4 }
|
|
|
|
cadSnmpRemoteEngineType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual (1),
|
|
auto (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type to indicate the remote engineID is manually configured or
|
|
internally detected via SNMP V3 Informs probe response."
|
|
DEFVAL { manual }
|
|
::= { cadSnmpRemoteEngineEntry 5 }
|
|
|
|
cadSnmpRemoteEngineStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of this conceptual row."
|
|
::= { cadSnmpRemoteEngineEntry 6 }
|
|
|
|
--=========== Boot Param Objects =============================
|
|
|
|
cadSysBootMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Mac address of system controller "
|
|
::= { cadSysBootParams 1 }
|
|
|
|
cadSysBootFpIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Ip address of E6000 front panel ethernet port "
|
|
::= { cadSysBootParams 2 }
|
|
|
|
cadSysBootFpSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" E6000 front port interface subnet mask "
|
|
::= { cadSysBootParams 3 }
|
|
|
|
cadSysBootDefaultGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Default gateway "
|
|
::= { cadSysBootParams 6 }
|
|
|
|
cadSysBootTimeOffset OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Time offset (seconds) from UTC "
|
|
::= { cadSysBootParams 7 }
|
|
|
|
cadSysBootTimeServer OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Ip address of TOD server "
|
|
::= { cadSysBootParams 8 }
|
|
|
|
cadSysBootTimeServerConnType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tcp(1),
|
|
udp(2),
|
|
none(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Protocol (tcp/udp) used to connect to TOD server "
|
|
DEFVAL { udp }
|
|
::= { cadSysBootParams 9 }
|
|
|
|
cadSysBootStartupApplication OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
bootprobe(1),
|
|
bootapplication(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Startup mode of the E6000 "
|
|
DEFVAL { bootapplication }
|
|
::= { cadSysBootParams 10 }
|
|
|
|
cadSysBootStartupDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (1..60)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Delay (in seconds) allowing changes before booting application "
|
|
DEFVAL { 1 }
|
|
::= { cadSysBootParams 11 }
|
|
|
|
cadSysBootSelection OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Bootloader to use (1 or 2) "
|
|
DEFVAL { 1 }
|
|
::= { cadSysBootParams 12 }
|
|
|
|
cadSysBootBaud OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
" Baud rate of front panel serial port "
|
|
DEFVAL { 9600 }
|
|
::= { cadSysBootParams 13 }
|
|
|
|
cadSysBootFpBIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Ip address of E6000 side B front panel ethernet port "
|
|
::= { cadSysBootParams 15 }
|
|
|
|
cadSysBootParity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial parity of console port. Valid values are N (no parity),
|
|
E (even parity), and O (odd parity)."
|
|
DEFVAL { "N" }
|
|
::= { cadSysBootParams 16 }
|
|
|
|
--=========== Reload Control Objects =============================
|
|
|
|
cadSysReloadOperation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
reloadImage(1),
|
|
reloadCommit(2),
|
|
reloadActive(3),
|
|
reloadHitless(4),
|
|
reloadWritemem(5),
|
|
reloadErasemem(6),
|
|
reloadPatchInstall(7),
|
|
reloadPatchRemove(8),
|
|
reloadPatchApply(9),
|
|
none(99)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Control object for E6000 reload, reading this object always returns none(99) "
|
|
DEFVAL { none }
|
|
::= { cadSysReload 1 }
|
|
|
|
cadSysReloadImageName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Image name to use in reloadImage operation "
|
|
DEFVAL { "" }
|
|
::= { cadSysReload 2 }
|
|
|
|
cadSysReloadStatus OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
idle(0),
|
|
inProgress(1),
|
|
localCheckImage(2),
|
|
localCommit(3),
|
|
remoteCommit(4),
|
|
remoteCopyImage(5),
|
|
remoteCheckImage(6),
|
|
patchInstall(7),
|
|
localReboot(8),
|
|
patchRemove(9),
|
|
remoteFirmwareUpdate(10),
|
|
firmwareUpdate(11),
|
|
waitStandby(12),
|
|
remotePatchInstall(13),
|
|
writeMem(14),
|
|
bundling(15),
|
|
unbundling(16),
|
|
complete(17),
|
|
abort(18),
|
|
remotePatchRemove(19),
|
|
remoteWriteMem(20),
|
|
eraseMem(21),
|
|
remoteEraseMem(22),
|
|
preloadCams(23),
|
|
localInstallImage(24),
|
|
remoteInstallImage(25),
|
|
localPreloadRsm(26),
|
|
remotePreloadRsm(27),
|
|
remoteCommitRsm(28),
|
|
copyImage(29),
|
|
remoteFirmwareUpdateRsm(30),
|
|
patchApplyCheck(31),
|
|
waitSoftswitch(32),
|
|
waitSpareCamsReset(33),
|
|
waitCamsReset(34)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Status object for E6000 reload "
|
|
DEFVAL { { idle } }
|
|
::= { cadSysReload 3 }
|
|
|
|
cadSysReloadStatusDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Textual description of reload status "
|
|
DEFVAL { "" }
|
|
::= { cadSysReload 4 }
|
|
|
|
cadSysReloadPatchName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Patch image name to use in patch operations "
|
|
DEFVAL { "" }
|
|
::= { cadSysReload 5 }
|
|
|
|
--=========== Image Status Objects =============================
|
|
|
|
cadSysImageFile OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Image filename for current E6000 image "
|
|
::= { cadSysImage 1 }
|
|
|
|
cadSysImageId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Image identifier for current E6000 image "
|
|
::= { cadSysImage 2 }
|
|
|
|
cadSysImageName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Image name for current E6000 image "
|
|
::= { cadSysImage 3 }
|
|
|
|
cadSysImageComponentCount OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Image component count for current E6000 image "
|
|
::= { cadSysImage 4 }
|
|
|
|
--=========== Dictionary Objects =============================
|
|
|
|
cadSysDictionaryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadSysDictionaryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Table describing internal state of database. "
|
|
::= { cadSysDictionary 1 }
|
|
|
|
cadSysDictionaryEntry OBJECT-TYPE
|
|
SYNTAX CadSysDictionaryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Describes the internal state of an individual table. "
|
|
INDEX { cadSysDictionaryTableId }
|
|
::= { cadSysDictionaryTable 1 }
|
|
|
|
CadSysDictionaryEntry ::= SEQUENCE {
|
|
cadSysDictionaryTableId Unsigned32,
|
|
cadSysDictionaryName DisplayString,
|
|
cadSysDictionaryDynamic TruthValue,
|
|
cadSysDictionaryNumberEntries Integer32,
|
|
cadSysDictionaryCurrentVer Unsigned32,
|
|
cadSysDictionaryPersistentVer Unsigned32,
|
|
cadSysDictionaryModuleVer Unsigned32
|
|
}
|
|
|
|
cadSysDictionaryTableId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Internal identifier for this MIB data."
|
|
::= { cadSysDictionaryEntry 1 }
|
|
|
|
cadSysDictionaryName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Internal name for this MIB data."
|
|
::= { cadSysDictionaryEntry 2 }
|
|
|
|
cadSysDictionaryDynamic OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether table is persistent or volatile only."
|
|
::= { cadSysDictionaryEntry 3 }
|
|
|
|
cadSysDictionaryNumberEntries OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current number of rows contained in the MIB table."
|
|
::= { cadSysDictionaryEntry 4 }
|
|
|
|
cadSysDictionaryCurrentVer OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current internal dynamic version number of the MIB table."
|
|
::= { cadSysDictionaryEntry 5 }
|
|
|
|
cadSysDictionaryPersistentVer OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current internal version number of the MIB table on flash."
|
|
::= { cadSysDictionaryEntry 6 }
|
|
|
|
cadSysDictionaryModuleVer OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current internal version number of the schema of the MIB table."
|
|
::= { cadSysDictionaryEntry 7 }
|
|
|
|
--=========== Configuration Objects =============================
|
|
|
|
cadSysConfigSaveTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The date and time of the last write of the configuration to nvram. "
|
|
::= { cadSysConfiguration 1 }
|
|
|
|
--== Class of Service to Quality of Service Mapping Objects ====
|
|
--
|
|
-- These cadCostoQosMapping objects only apply to 1.0 flows.
|
|
-- To configure 1.1 flows, the objects in the docsQosParamSetTable
|
|
-- should be used.
|
|
--
|
|
|
|
cadCosToQosMappingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadCosToQosMappingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of COS to QOS Mapping data"
|
|
::= { cadCosToQosMapping 9 }
|
|
|
|
cadCosToQosMappingEntry OBJECT-TYPE
|
|
SYNTAX CadCosToQosMappingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This entry contains all of the data to map
|
|
1.0 COS to 1.1 QOS parameters."
|
|
INDEX { cadCosToQosMappingIndex }
|
|
::= { cadCosToQosMappingTable 1 }
|
|
|
|
CadCosToQosMappingEntry ::= SEQUENCE {
|
|
cadCosToQosMappingIndex Integer32,
|
|
cadCosUpMaxTrafficBurst Unsigned32,
|
|
cadCosDnMaxTrafficBurst Unsigned32,
|
|
cadCosDnMinReservedRate BitRate,
|
|
cadCosUpMinReservedPkt Integer32,
|
|
cadCosDnMinReservedPkt Integer32,
|
|
cadCosUpTosAndMask OCTET STRING,
|
|
cadCosUpTosOrMask OCTET STRING,
|
|
cadCosDnMaxLatency Unsigned32,
|
|
cadCosDnPriority Integer32,
|
|
cadCosDnPeakTrafficRate BitRate,
|
|
cadCosUpPeakTrafficRate BitRate
|
|
}
|
|
|
|
cadCosToQosMappingIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..16)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB
|
|
object docsQosParamSetMaxTrafficBurst"
|
|
::= { cadCosToQosMappingEntry 1 }
|
|
|
|
cadCosUpMaxTrafficBurst OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB
|
|
object docsQosParamSetMaxTrafficBurst"
|
|
DEFVAL { 3044 }
|
|
::= { cadCosToQosMappingEntry 2 }
|
|
|
|
cadCosDnMaxTrafficBurst OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The downstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB
|
|
object docsQosParamSetMaxTrafficBurst"
|
|
DEFVAL { 96000 }
|
|
::= { cadCosToQosMappingEntry 3 }
|
|
|
|
cadCosDnMinReservedRate OBJECT-TYPE
|
|
SYNTAX BitRate
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The downstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB
|
|
object docsQosParamSetMinReservedRate"
|
|
DEFVAL { 0 }
|
|
::= { cadCosToQosMappingEntry 4 }
|
|
|
|
cadCosUpMinReservedPkt OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB
|
|
object docsQosParamSetMinReservedPkt"
|
|
DEFVAL { 0 }
|
|
::= { cadCosToQosMappingEntry 5 }
|
|
|
|
cadCosDnMinReservedPkt OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The downstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB
|
|
object docsQosParamSetMinReservedPkt"
|
|
DEFVAL { 0 }
|
|
::= { cadCosToQosMappingEntry 6 }
|
|
|
|
cadCosUpTosAndMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB
|
|
object docsQosParamSetTosAndMask"
|
|
DEFVAL { 'ff'h }
|
|
::= { cadCosToQosMappingEntry 7 }
|
|
|
|
cadCosUpTosOrMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB
|
|
object docsQosParamSetTosOrMask"
|
|
DEFVAL { '00'h }
|
|
::= { cadCosToQosMappingEntry 8 }
|
|
|
|
cadCosDnMaxLatency OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB
|
|
object docsQosParamSetMaxLatency"
|
|
DEFVAL { 0 }
|
|
::= { cadCosToQosMappingEntry 9 }
|
|
|
|
cadCosDnPriority OBJECT-TYPE
|
|
SYNTAX Integer32 (-1|0..7)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The downstream channel priority to use. A -1 indicates
|
|
that the current method of using the upstream channel
|
|
priority should be used."
|
|
DEFVAL { -1 }
|
|
::= { cadCosToQosMappingEntry 10 }
|
|
|
|
cadCosDnPeakTrafficRate OBJECT-TYPE
|
|
SYNTAX BitRate
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Peak traffic rate shaped to while traffic still conforms to
|
|
the policing parameters (Tmax and Burst). If the peak rate is set to a
|
|
value greater than Tmax, then the traffic will be shaped to the peak
|
|
rate until the traffic is non-conforming to the policing parameters,
|
|
and then the traffic will be shaped to the Tmax rate. If the peak rate
|
|
is less than the Tmax for a flow, then all traffic for that flow will shaped
|
|
to the Tmax rate. Setting the peak rate to a value of 0 will result in all
|
|
flows being limited to Tmax at all times. Setting the peak rate to a
|
|
value of 0xffffffff will result in flows having virtually unlimited
|
|
bandwidth until their burst size is used up. This parameter only has
|
|
meaning for flows on downstreams that are shaped."
|
|
DEFVAL { 0 }
|
|
::= { cadCosToQosMappingEntry 11 }
|
|
|
|
cadCosUpPeakTrafficRate OBJECT-TYPE
|
|
SYNTAX BitRate
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Peak traffic rate shaped to while traffic still conforms to
|
|
the policing parameters (Tmax and Burst). If the peak rate is set to a
|
|
value greater than Tmax, then the traffic will be shaped to the peak
|
|
rate until the traffic is non-conforming to the policing parameters,
|
|
and then the traffic will be shaped to the Tmax rate. If the peak rate
|
|
is less than the Tmax for a flow, then all traffic for that flow will shaped
|
|
to the Tmax rate. Setting the peak rate to a value of 0 will result in all
|
|
flows being limited to Tmax at all times. Setting the peak rate to a
|
|
value of 0xffffffff will result in flows having virtually unlimited
|
|
bandwidth until their burst size is used up. This parameter only has
|
|
meaning for upstream flows."
|
|
DEFVAL { 0 }
|
|
::= { cadCosToQosMappingEntry 12 }
|
|
|
|
|
|
|
|
--=========== Key Chain Objects =============================
|
|
|
|
cadSysKeyChainKeyTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadSysKeyChainKeyEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Table describing key-chain key provisioned data. "
|
|
::= { cadSysKeyChain 1 }
|
|
|
|
cadSysKeyChainKeyEntry OBJECT-TYPE
|
|
SYNTAX CadSysKeyChainKeyEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Describes the provisioned data for a key in a key-chain. "
|
|
INDEX { cadSysKeyChainName, cadSysKeyChainKeySequenceId }
|
|
::= { cadSysKeyChainKeyTable 1 }
|
|
|
|
CadSysKeyChainKeyEntry ::= SEQUENCE {
|
|
cadSysKeyChainName OCTET STRING,
|
|
cadSysKeyChainKeySequenceId Unsigned32,
|
|
cadSysKeyChainKey OCTET STRING,
|
|
cadSysKeyChainKeyAcceptStartTime DateAndTime,
|
|
cadSysKeyChainKeyAcceptStopTime DateAndTime,
|
|
cadSysKeyChainKeyAcceptInfiniteLifetime TruthValue,
|
|
cadSysKeyChainKeySendStartTime DateAndTime,
|
|
cadSysKeyChainKeySendStopTime DateAndTime,
|
|
cadSysKeyChainKeySendInfiniteLifetime TruthValue,
|
|
cadSysKeyChainKeyRowStatus RowStatus
|
|
}
|
|
|
|
cadSysKeyChainName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..16))
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The key-chain name."
|
|
::= { cadSysKeyChainKeyEntry 1 }
|
|
|
|
cadSysKeyChainKeySequenceId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sequence id of the key."
|
|
::= { cadSysKeyChainKeyEntry 2 }
|
|
|
|
cadSysKeyChainKey OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The key string."
|
|
::= { cadSysKeyChainKeyEntry 3 }
|
|
|
|
cadSysKeyChainKeyAcceptStartTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The start time when this key is valid for received packets."
|
|
::= { cadSysKeyChainKeyEntry 4 }
|
|
|
|
cadSysKeyChainKeyAcceptStopTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The stop time when this key is no longer valid for received packets."
|
|
::= { cadSysKeyChainKeyEntry 5 }
|
|
|
|
cadSysKeyChainKeyAcceptInfiniteLifetime OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If this value is set to true, the key has an infinite lifetime for
|
|
received packets. Otherwise use the accept start and stop time to
|
|
determine the lifetime."
|
|
DEFVAL { true }
|
|
::= { cadSysKeyChainKeyEntry 6 }
|
|
|
|
cadSysKeyChainKeySendStartTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The start time when this key is valid for sending packets."
|
|
::= { cadSysKeyChainKeyEntry 7 }
|
|
|
|
cadSysKeyChainKeySendStopTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The stop time when this key is no longer valid for sending packets."
|
|
::= { cadSysKeyChainKeyEntry 8 }
|
|
|
|
cadSysKeyChainKeySendInfiniteLifetime OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If this value is set to true, the key has an infinite lifetime for
|
|
sending packets. Otherwise use the send start and stop time to
|
|
determine the lifetime."
|
|
DEFVAL { true }
|
|
::= { cadSysKeyChainKeyEntry 9 }
|
|
|
|
cadSysKeyChainKeyRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The row status variable used according to row installation
|
|
and removal convention. In our case, we have simplified this
|
|
to the usage of only the following states - active, createAndGo,
|
|
and destroy. Other three states notInService, notReady and
|
|
createAndWait are not permitted."
|
|
::= { cadSysKeyChainKeyEntry 10 }
|
|
|
|
--=========== Processor Protocol Policing Objects =============================
|
|
|
|
-- configuration objects
|
|
|
|
cadSysProcRouterControlGlobalPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted global protocol packet throttle rate to
|
|
the Router Control processor."
|
|
DEFVAL { 2500 }
|
|
::= { cadSysProcPolicingConfig 1 }
|
|
|
|
cadSysProcArpPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted ARP packet rate to the Router Control processor."
|
|
DEFVAL { 700 }
|
|
::= { cadSysProcPolicingConfig 2 }
|
|
|
|
cadSysProcDhcpPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maxmimu permitted DHCP packet rate to the Router Control processor."
|
|
DEFVAL { 750 }
|
|
::= { cadSysProcPolicingConfig 3 }
|
|
|
|
cadSysProcIcmpPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted ICMP(IPv4) packet rate to the Router Control processor."
|
|
DEFVAL { 500 }
|
|
::= { cadSysProcPolicingConfig 4 }
|
|
|
|
cadSysProcOspfPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted OSPFv2 packet rate to the Router Control processor."
|
|
DEFVAL { 750 }
|
|
::= { cadSysProcPolicingConfig 5 }
|
|
|
|
cadSysProcRipPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted RIP packet rate to the Router Control processor."
|
|
DEFVAL { 500 }
|
|
::= { cadSysProcPolicingConfig 6 }
|
|
|
|
cadSysProcIgmpPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted IGMP packet rate to the Router Control processor."
|
|
DEFVAL { 500 }
|
|
::= { cadSysProcPolicingConfig 7 }
|
|
|
|
cadSysProcRouterControlOtherPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The other protocol packet rate to the Router Control processor."
|
|
DEFVAL { 500 }
|
|
::= { cadSysProcPolicingConfig 8 }
|
|
|
|
cadSysProcSnmpPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SNMP packet rate to the System Control processor."
|
|
DEFVAL { 650 }
|
|
::= { cadSysProcPolicingConfig 10 }
|
|
|
|
cadSysProcTftpPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TFTP packet rate to the processor."
|
|
DEFVAL { 750 }
|
|
::= { cadSysProcPolicingConfig 11 }
|
|
|
|
cadSysProcIsisPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IS-IS packet rate to the processor."
|
|
DEFVAL { 750 }
|
|
::= { cadSysProcPolicingConfig 12 }
|
|
|
|
cadSysProcNdPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted Neighbor Discover (ND) packet throttle
|
|
rate to the Router Control processor. This includes IPv6 Router
|
|
Solicitation, Router Advertise, Neighbor Solicitation, Neighbor
|
|
Advertise, and Redirect messages."
|
|
DEFVAL { 700 }
|
|
::= { cadSysProcPolicingConfig 13 }
|
|
|
|
cadSysProcDhcpIpv6PacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted DHCP (Ipv6) packet throttle
|
|
rate to the Router Control processor."
|
|
DEFVAL { 500 }
|
|
::= { cadSysProcPolicingConfig 14 }
|
|
|
|
cadSysProcIcmpIpv6PacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted ICMP (Ipv6 other than Neighbor
|
|
Discover and MLD) packet throttle rate to the Router
|
|
Control processor."
|
|
DEFVAL { 500 }
|
|
::= { cadSysProcPolicingConfig 15 }
|
|
|
|
cadSysProcMldPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted MLD (version 1 and version 2)
|
|
packet throttle rate to the Router Control processor."
|
|
DEFVAL { 500 }
|
|
::= { cadSysProcPolicingConfig 16 }
|
|
|
|
cadSysProcBgpPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted BGP packet throttle rate to
|
|
the Router Control processor."
|
|
DEFVAL { 500 }
|
|
::= { cadSysProcPolicingConfig 17 }
|
|
|
|
cadSysProcPimPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted PIM packet throttle rate to
|
|
the Router Control processor."
|
|
DEFVAL { 100 }
|
|
::= { cadSysProcPolicingConfig 18 }
|
|
|
|
cadSysProcSnmpCmPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted SNMP (from CMs) packet throttle rate to
|
|
the Router Control processor."
|
|
DEFVAL { 100 }
|
|
::= { cadSysProcPolicingConfig 19 }
|
|
|
|
cadSysProcCopsPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted Cops packet throttle rate to
|
|
the Router Control processor."
|
|
DEFVAL { 300 }
|
|
::= { cadSysProcPolicingConfig 20 }
|
|
|
|
cadSysProcTelnetPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted Telnet packet throttle rate to
|
|
the Router Control processor."
|
|
DEFVAL { 300 }
|
|
::= { cadSysProcPolicingConfig 21 }
|
|
|
|
cadSysProcOspfv3PacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted OSPFv3 packet rate to the Router Control processor."
|
|
DEFVAL { 750 }
|
|
::= { cadSysProcPolicingConfig 22 }
|
|
|
|
cadSysProcTftpIpv6PacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The TFTP (IPv6) packet rate to the processor."
|
|
DEFVAL { 750 }
|
|
::= { cadSysProcPolicingConfig 23 }
|
|
|
|
cadSysProcEventIcmpPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted ICMP event packet rate to the Router Control processor."
|
|
DEFVAL { 700 }
|
|
::= { cadSysProcPolicingConfig 24 }
|
|
|
|
cadSysProcEventNoRoutePacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted No Route event packet rate to the Router Control processor."
|
|
DEFVAL { 700 }
|
|
::= { cadSysProcPolicingConfig 25 }
|
|
|
|
cadSysProcEventIcmpIpv6PacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted ICMP (IPv6) event packet rate to the Router Control processor."
|
|
DEFVAL { 700 }
|
|
::= { cadSysProcPolicingConfig 26 }
|
|
|
|
cadSysProcEventNoRouteIpv6PacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted No Route (IPv6) event packet rate to the Router Control processor."
|
|
DEFVAL { 700 }
|
|
::= { cadSysProcPolicingConfig 27 }
|
|
|
|
cadSysProcEventArpPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted ARP event packet rate to the Router Control processor."
|
|
DEFVAL { 700 }
|
|
::= { cadSysProcPolicingConfig 28 }
|
|
|
|
cadSysProcEventNdPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted ND event packet rate to the Router Control processor."
|
|
DEFVAL { 700 }
|
|
::= { cadSysProcPolicingConfig 29 }
|
|
|
|
cadSysProcEventTtlPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted TTL event packet rate to the Router Control processor."
|
|
DEFVAL { 100 }
|
|
::= { cadSysProcPolicingConfig 30 }
|
|
|
|
cadSysProcEventTtlIpv6PacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted TTL (IPv6) event packet rate to the Router Control processor."
|
|
DEFVAL { 100 }
|
|
::= { cadSysProcPolicingConfig 31 }
|
|
|
|
cadSysProcEventDadPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted DAD event packet rate to the Router Control processor."
|
|
DEFVAL { 500 }
|
|
::= { cadSysProcPolicingConfig 32 }
|
|
|
|
cadSysProcEventDefaultPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted Default event packet rate to the Router Control processor."
|
|
DEFVAL { 3000 }
|
|
::= { cadSysProcPolicingConfig 33 }
|
|
|
|
cadSysProcLdpPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The LDP (UDP and TCP) packet rate to the processor."
|
|
DEFVAL { 750 }
|
|
::= { cadSysProcPolicingConfig 34 }
|
|
|
|
cadSysProcClearPolicingCounts OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable always returns false(2) upon reading.
|
|
When set to true(1), all objects under cadSysProcPolicingCounts are cleared."
|
|
|
|
::= { cadSysProcPolicingConfig 35 }
|
|
|
|
cadSysProcLacpPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The total LACP packet rate to the processor."
|
|
DEFVAL { 200 }
|
|
::= { cadSysProcPolicingConfig 36 }
|
|
|
|
|
|
cadSysProcVrepPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The maximum permitted D6/VREP packet rate to the processor."
|
|
DEFVAL { 500 }
|
|
::= { cadSysProcPolicingConfig 37 }
|
|
|
|
cadSysProcVpmePacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The maximum permitted VPME packet rate to the processor."
|
|
DEFVAL { 30 }
|
|
::= { cadSysProcPolicingConfig 38 }
|
|
|
|
cadSysProcErmRpcPacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "packets/second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum permitted RPC packet rate from an RPC ERM processor."
|
|
DEFVAL { 300 }
|
|
::= { cadSysProcPolicingConfig 39 }
|
|
|
|
|
|
|
|
--
|
|
-- count objects
|
|
--
|
|
cadSysProcRouterControlGlobalPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of packets received passed to the Router Control processor."
|
|
::= { cadSysProcPolicingCounts 1 }
|
|
|
|
cadSysProcRouterControlGlobalPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of packets received that are dropped by the Router Control processor."
|
|
::= { cadSysProcPolicingCounts 2 }
|
|
|
|
cadSysProcArpPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of ARP packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 4 }
|
|
|
|
cadSysProcArpPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of ARP packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 5 }
|
|
|
|
cadSysProcDhcpPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of DHCP packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 7 }
|
|
|
|
cadSysProcDhcpPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of DHCP packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 8 }
|
|
|
|
-- cadSysProcDhcpPacketsSent removed. do NOT reuse the OID
|
|
-- ::= { cadSysProcPolicingCounts 9 }
|
|
|
|
cadSysProcIcmpPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of ICMP packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 10 }
|
|
|
|
cadSysProcIcmpPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of ICMP packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 11 }
|
|
|
|
cadSysProcOspfPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of OSPFv2 packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 13 }
|
|
|
|
cadSysProcOspfPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of OSPFv2 packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 14 }
|
|
|
|
cadSysProcRipPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of RIP packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 16 }
|
|
|
|
cadSysProcRipPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of RIP packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 17 }
|
|
|
|
cadSysProcIgmpPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of IGMP packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 19 }
|
|
|
|
cadSysProcIgmpPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of IGMP packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 20 }
|
|
|
|
cadSysProcRouterControlOtherPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of other packets received passed to the Router Control processor."
|
|
::= { cadSysProcPolicingCounts 22 }
|
|
|
|
cadSysProcRouterControlOtherPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of other packets received that are dropped by the Router Control processor."
|
|
::= { cadSysProcPolicingCounts 23 }
|
|
|
|
cadSysProcSnmpPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of SNMP packets received passed to the System Control processor."
|
|
::= { cadSysProcPolicingCounts 25 }
|
|
|
|
cadSysProcSnmpPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of SNMP packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 26 }
|
|
|
|
cadSysProcTftpPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of TFTP packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 28 }
|
|
|
|
cadSysProcTftpPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of TFTP packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 29 }
|
|
|
|
cadSysProcIsisPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of IS-IS packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 31 }
|
|
|
|
cadSysProcIsisPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of IS-IS packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 32 }
|
|
|
|
cadSysProcNdPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Neighbor Discover packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 37 }
|
|
|
|
cadSysProcNdPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Neighbor Discover packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 38 }
|
|
|
|
cadSysProcDhcpIpv6PacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of DHCP(Ipv6) packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 40 }
|
|
|
|
cadSysProcDhcpIpv6PacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of DHCP(IPv6) packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 41 }
|
|
|
|
cadSysProcIcmpIpv6PacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of ICMP(Ipv6) packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 43 }
|
|
|
|
cadSysProcIcmpIpv6PacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of ICMP(IPv6) packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 44 }
|
|
|
|
cadSysProcMldPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of MLD packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 46 }
|
|
|
|
cadSysProcMldPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of MLD packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 47 }
|
|
|
|
cadSysProcBgpPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of BGP packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 49 }
|
|
|
|
cadSysProcBgpPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of BGP packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 50 }
|
|
|
|
cadSysProcPimPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of PIM packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 52 }
|
|
|
|
cadSysProcPimPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of PIM packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 53 }
|
|
|
|
cadSysProcSnmpCmPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of SNMP (from CMs) packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 55 }
|
|
|
|
cadSysProcSnmpCmPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of SNMP (from CMs) packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 56 }
|
|
|
|
cadSysProcCopsPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of COPS packets received passed to the System Control processor."
|
|
::= { cadSysProcPolicingCounts 58 }
|
|
|
|
cadSysProcCopsPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of COPS packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 59 }
|
|
|
|
cadSysProcTelnetPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of TELNET packets received passed to the System Control processor."
|
|
::= { cadSysProcPolicingCounts 61 }
|
|
|
|
cadSysProcTelnetPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of TELNET packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 62 }
|
|
|
|
cadSysProcOspfv3PacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of OSPFv3 packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 64 }
|
|
|
|
cadSysProcOspfv3PacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of OSPFv3 packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 65 }
|
|
|
|
-- cadSysProcOspfv3PacketsSent removed
|
|
-- ::= { cadSysProcPolicingCounts 66 }
|
|
|
|
cadSysProcTftpIpv6PacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of TFTP (IPv6) packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 67 }
|
|
|
|
cadSysProcTftpIpv6PacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of TFTP (IPv6) packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 68 }
|
|
|
|
-- cadSysProcTftpIpv6PacketsSent removed, do NOT reuse the OID
|
|
-- ::= { cadSysProcPolicingCounts 69 }
|
|
|
|
cadSysProcLdpPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of LDP (UDP and TCP) packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 70 }
|
|
|
|
cadSysProcLdpPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of LDP (UDP and TCP) packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 71 }
|
|
|
|
-- cadSysProcLdpPacketsSent removed, do NOT reuse the OID
|
|
-- ::= { cadSysProcPolicingCounts 72 }
|
|
|
|
--=========== NPU events to the host Objects ==============================
|
|
cadSysProcEventIcmpPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of ICMP event packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 73 }
|
|
|
|
cadSysProcEventIcmpPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of ICMP event packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 74 }
|
|
|
|
cadSysProcEventNoRoutePacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of No Route event packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 75 }
|
|
|
|
cadSysProcEventNoRoutePacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of No Route event packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 76 }
|
|
|
|
cadSysProcEventIcmpIpv6PacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of ICMP (IPv6) event packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 77 }
|
|
|
|
cadSysProcEventIcmpIpv6PacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of ICMP (IPv6) event packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 78 }
|
|
|
|
cadSysProcEventNoRouteIpv6PacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of No Route (IPv6) event packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 79 }
|
|
|
|
cadSysProcEventNoRouteIpv6PacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of No Route (IPv6) event packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 80 }
|
|
|
|
cadSysProcEventArpPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of ARP event packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 81 }
|
|
|
|
cadSysProcEventArpPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of ARP event packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 82 }
|
|
|
|
cadSysProcEventNdPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of ND event packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 83 }
|
|
|
|
cadSysProcEventNdPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of ND event packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 84 }
|
|
|
|
cadSysProcEventTtlPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of TTL event packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 85 }
|
|
|
|
cadSysProcEventTtlPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of TTL event packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 86 }
|
|
|
|
cadSysProcEventTtlIpv6PacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of TTL (IPv6) event packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 87 }
|
|
|
|
cadSysProcEventTtlIpv6PacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of TTL (IPv6) event packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 88 }
|
|
|
|
cadSysProcEventDadPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of DAD event packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 89 }
|
|
|
|
cadSysProcEventDadPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of DAD event packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 90 }
|
|
|
|
cadSysProcEventDefaultPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Default event packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 91 }
|
|
|
|
cadSysProcEventDefaultPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Default event packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 92 }
|
|
|
|
cadSysProcLacpPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of LACP packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 93 }
|
|
|
|
cadSysProcLacpPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of LACP packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 94 }
|
|
|
|
cadSysProcVrepPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of D6/VREP packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 95 }
|
|
|
|
cadSysProcVrepPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of D6/VREP packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 96 }
|
|
|
|
cadSysProcVpmePacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of VPME packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 97 }
|
|
|
|
cadSysProcVpmePacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of VPME packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 98 }
|
|
|
|
cadSysProcErmRpcPacketsReceivedPassed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of ERM RPC packets received passed to the processor."
|
|
::= { cadSysProcPolicingCounts 99 }
|
|
|
|
cadSysProcErmRpcPacketsReceivedDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of ERM RPC packets received that are dropped."
|
|
::= { cadSysProcPolicingCounts 100 }
|
|
|
|
|
|
--=========== Banner Objects ==============================
|
|
|
|
cadSysBannerMotdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadSysBannerMotdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Table describing the MOTD banner that is displayed before the login: prompt"
|
|
::= { cadSysBanner 1 }
|
|
|
|
cadSysBannerMotdEntry OBJECT-TYPE
|
|
SYNTAX CadSysBannerMotdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Describes a line in the MOTD banner"
|
|
INDEX { cadSysBannerMotdLine }
|
|
::= { cadSysBannerMotdTable 1 }
|
|
|
|
CadSysBannerMotdEntry ::= SEQUENCE {
|
|
cadSysBannerMotdLine Integer32,
|
|
cadSysBannerMotdText DisplayString,
|
|
cadSysBannerMotdRowStatus RowStatus
|
|
}
|
|
|
|
cadSysBannerMotdLine OBJECT-TYPE
|
|
SYNTAX Integer32 (1..100)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The line number"
|
|
::= { cadSysBannerMotdEntry 1 }
|
|
|
|
cadSysBannerMotdText OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MOTD banner text"
|
|
::= { cadSysBannerMotdEntry 2 }
|
|
|
|
cadSysBannerMotdRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The row status variable used according to row installation
|
|
and removal convention. In our case, we have simplified this
|
|
to the usage of only the following states - active, createAndGo,
|
|
and destroy. Other three states notInService, notReady and
|
|
createAndWait are not permitted."
|
|
::= { cadSysBannerMotdEntry 3 }
|
|
|
|
cadSysBannerLoginTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadSysBannerLoginEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Table describing the login banner that is displayed after the MOTD banner and before the login: prompt"
|
|
::= { cadSysBanner 2 }
|
|
|
|
cadSysBannerLoginEntry OBJECT-TYPE
|
|
SYNTAX CadSysBannerLoginEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Describes a line in the login banner"
|
|
INDEX { cadSysBannerLoginLine }
|
|
::= { cadSysBannerLoginTable 1 }
|
|
|
|
CadSysBannerLoginEntry ::= SEQUENCE {
|
|
cadSysBannerLoginLine Integer32,
|
|
cadSysBannerLoginText DisplayString,
|
|
cadSysBannerLoginRowStatus RowStatus
|
|
}
|
|
|
|
cadSysBannerLoginLine OBJECT-TYPE
|
|
SYNTAX Integer32 (1..100)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The line number"
|
|
::= { cadSysBannerLoginEntry 1 }
|
|
|
|
cadSysBannerLoginText OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The login banner text"
|
|
::= { cadSysBannerLoginEntry 2 }
|
|
|
|
cadSysBannerLoginRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The row status variable used according to row installation
|
|
and removal convention. In our case, we have simplified this
|
|
to the usage of only the following states - active, createAndGo,
|
|
and destroy. Other three states notInService, notReady and
|
|
createAndWait are not permitted."
|
|
::= { cadSysBannerLoginEntry 3 }
|
|
|
|
cadSysBannerExecTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadSysBannerExecEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { cadSysBanner 3 }
|
|
|
|
cadSysBannerExecEntry OBJECT-TYPE
|
|
SYNTAX CadSysBannerExecEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { cadSysBannerExecLine }
|
|
::= { cadSysBannerExecTable 1 }
|
|
|
|
CadSysBannerExecEntry ::= SEQUENCE {
|
|
cadSysBannerExecLine Integer32,
|
|
cadSysBannerExecText DisplayString,
|
|
cadSysBannerExecRowStatus RowStatus
|
|
}
|
|
|
|
cadSysBannerExecLine OBJECT-TYPE
|
|
SYNTAX Integer32 (1..25)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of this banner line."
|
|
::= { cadSysBannerExecEntry 1 }
|
|
|
|
cadSysBannerExecText OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ascii text of this banner line."
|
|
::= { cadSysBannerExecEntry 2 }
|
|
|
|
cadSysBannerExecRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The row status variable used according to row installation
|
|
and removal convention. In our case, we have simplified this
|
|
to the usage of only the following states - active, createAndGo,
|
|
and destroy. Other three states notInService, notReady and
|
|
createAndWait are not permitted."
|
|
::= { cadSysBannerExecEntry 3 }
|
|
|
|
cadSysBannerIncomingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadSysBannerIncomingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { cadSysBanner 4 }
|
|
|
|
cadSysBannerIncomingEntry OBJECT-TYPE
|
|
SYNTAX CadSysBannerIncomingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { cadSysBannerIncomingLine }
|
|
::= { cadSysBannerIncomingTable 1 }
|
|
|
|
CadSysBannerIncomingEntry ::= SEQUENCE {
|
|
cadSysBannerIncomingLine Integer32,
|
|
cadSysBannerIncomingText DisplayString,
|
|
cadSysBannerIncomingRowStatus RowStatus
|
|
}
|
|
|
|
cadSysBannerIncomingLine OBJECT-TYPE
|
|
SYNTAX Integer32 (1..25)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { cadSysBannerIncomingEntry 1 }
|
|
|
|
cadSysBannerIncomingText OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { cadSysBannerIncomingEntry 2 }
|
|
|
|
cadSysBannerIncomingRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The row status variable used according to row installation
|
|
and removal convention. In our case, we have simplified this
|
|
to the usage of only the following states - active, createAndGo,
|
|
and destroy. Other three states notInService, notReady and
|
|
createAndWait are not permitted."
|
|
::= { cadSysBannerIncomingEntry 3 }
|
|
|
|
--=========== Server Objects ==============================
|
|
|
|
cadSysServerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadSysServerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Table describing the (INET) services that should run on the SCM."
|
|
::= { cadSysServer 1 }
|
|
|
|
cadSysServerEntry OBJECT-TYPE
|
|
SYNTAX CadSysServerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Describes an INET service and whether it is enabled "
|
|
INDEX { cadSysServerType }
|
|
::= { cadSysServerTable 1 }
|
|
|
|
CadSysServerEntry ::= SEQUENCE {
|
|
cadSysServerType ServerType,
|
|
cadSysServerAdminState AdminState
|
|
}
|
|
|
|
cadSysServerType OBJECT-TYPE
|
|
SYNTAX ServerType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The service type"
|
|
::= { cadSysServerEntry 1 }
|
|
|
|
cadSysServerAdminState OBJECT-TYPE
|
|
SYNTAX AdminState
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The administrative state of the server."
|
|
DEFVAL { up }
|
|
::= { cadSysServerEntry 2 }
|
|
|
|
|
|
--=========== Patch Parameter Objects =============================
|
|
|
|
cadSysPatchParamTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadSysPatchParamEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of patch parameters."
|
|
::= { cadSysPatchParams 1 }
|
|
|
|
cadSysPatchParamEntry OBJECT-TYPE
|
|
SYNTAX CadSysPatchParamEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry of an individual patch parameter."
|
|
INDEX { cadSysPatchParamIndex }
|
|
::= { cadSysPatchParamTable 1 }
|
|
|
|
CadSysPatchParamEntry ::= SEQUENCE {
|
|
cadSysPatchParamIndex Integer32,
|
|
cadSysPatchParamName DisplayString,
|
|
cadSysPatchParamValue DisplayString,
|
|
cadSysPatchParamDescription DisplayString,
|
|
cadSysPatchParamRowStatus RowStatus
|
|
}
|
|
|
|
cadSysPatchParamIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..1000)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The patch parameter index."
|
|
::= { cadSysPatchParamEntry 1 }
|
|
|
|
cadSysPatchParamName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The patch parameter name."
|
|
::= { cadSysPatchParamEntry 2 }
|
|
|
|
cadSysPatchParamValue OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The patch parameter value."
|
|
::= { cadSysPatchParamEntry 3 }
|
|
|
|
cadSysPatchParamDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The patch parameter description."
|
|
::= { cadSysPatchParamEntry 4 }
|
|
|
|
cadSysPatchParamRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The row status variable used according to row installation
|
|
and removal convention. In our case, we have simplified this
|
|
to the usage of only the following states - active, createAndGo,
|
|
and destroy. Other three states notInService, notReady and
|
|
createAndWait are not permitted."
|
|
::= { cadSysPatchParamEntry 5 }
|
|
|
|
|
|
--=========== Maintenance Configuration ==============================
|
|
|
|
cadSysMtceStatusCloneMonitorThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32 (2750..6250)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Timeout during normal operation."
|
|
DEFVAL { 6000 }
|
|
::= { cadSysMtceParams 8 }
|
|
|
|
cadSysMtceStatusCloneInitThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32 (3000..9000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Timeout on initialization for first status message."
|
|
DEFVAL { 7500 }
|
|
::= { cadSysMtceParams 9 }
|
|
|
|
cadSysMtceStatusCloneRcvyThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32 (120000..360000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Timeout following clone side recovery."
|
|
DEFVAL { 240000 }
|
|
::= { cadSysMtceParams 10 }
|
|
|
|
cadSysMtceBasePingRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (750..2250)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Interval between system maintenance polling of monitored threads."
|
|
DEFVAL { 2000 }
|
|
::= { cadSysMtceParams 11 }
|
|
|
|
cadSysMtceOvSensitivity OBJECT-TYPE
|
|
SYNTAX OverloadThreshold
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the sensitivity of user overload to changes in
|
|
internal work load. Higher sensitivity results in more
|
|
rapid change of user overload in response to a change in
|
|
the internal work load."
|
|
DEFVAL { med }
|
|
::= { cadSysMtceParams 12 }
|
|
|
|
cadSysMtceOvThreshold OBJECT-TYPE
|
|
SYNTAX OverloadThreshold
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the overall threshold of user overload transitions.
|
|
Higher thresholds require a longer time in an internal overload
|
|
state before user overload transitions occur."
|
|
DEFVAL { med }
|
|
::= { cadSysMtceParams 13 }
|
|
|
|
cadSysMtceDULPacketInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32(0|10000..900000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Interval between maintenance polling of monitored BroadCom devices.
|
|
Setting the value to zero will disable BroadCom device monitoring."
|
|
DEFVAL { 10000 }
|
|
::= { cadSysMtceParams 14 }
|
|
|
|
|
|
--=========== Data Management ==============================--
|
|
|
|
cadSysDataServerDataTimeout OBJECT-TYPE
|
|
SYNTAX Unsigned32 (50000..500000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time allowed for Data Query/Update to be processed."
|
|
DEFVAL { 50000 }
|
|
::= { cadSysDataServer 1 }
|
|
|
|
|
|
cadSysDataServerDataEventsPerCycle OBJECT-TYPE
|
|
SYNTAX Unsigned32 (10..200)
|
|
UNITS "events/cycle"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of data events allowed per cycle."
|
|
DEFVAL { 40 }
|
|
::= { cadSysDataServer 2 }
|
|
|
|
cadSysDataServerDataSyncTimeout OBJECT-TYPE
|
|
SYNTAX Unsigned32 (8000..100000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of data events allowed per cycle."
|
|
DEFVAL { 80000 }
|
|
::= { cadSysDataServer 3 }
|
|
|
|
cadSysDataServerSnmpReadAheadEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When this value is set to true Snmp read ahead
|
|
is performed."
|
|
DEFVAL { true }
|
|
::= { cadSysDataServer 4 }
|
|
|
|
cadSysDataServerSnmpReadAheadMax OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..20)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is the maximum number of records to read ahead"
|
|
DEFVAL { 1 }
|
|
::= { cadSysDataServer 5 }
|
|
|
|
cadSysDataServerSnmpRefreshTime OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..1200)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value represents how old a database record can be to be used."
|
|
DEFVAL { 1 }
|
|
::= { cadSysDataServer 6 }
|
|
|
|
|
|
cadSysDataServerSyncDataEventsPerCycle OBJECT-TYPE
|
|
SYNTAX Unsigned32 (40..100)
|
|
UNITS "events/cycle"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is the maximum number of Sync events that will be
|
|
processed per cycle."
|
|
DEFVAL { 40 }
|
|
::= { cadSysDataServer 7 }
|
|
|
|
|
|
cadSysDataServerLoPriDataEventsPerCycle OBJECT-TYPE
|
|
SYNTAX Unsigned32 (10..100)
|
|
UNITS "events/cycle"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is the maximum number of Low Priority Sync events
|
|
to be processed per cycle."
|
|
DEFVAL { 10 }
|
|
::= { cadSysDataServer 8 }
|
|
|
|
--============================ Source Interface and Address ===========================
|
|
|
|
cadSysSourceAddressTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadSysSourceAddressEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of source interface addresses for administrative services"
|
|
::= { cadSysSourceAddress 1 }
|
|
|
|
cadSysSourceAddressEntry OBJECT-TYPE
|
|
SYNTAX CadSysSourceAddressEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This entry contains the configured source IPv4 and/or IPv6 address for each administrative service.
|
|
If configured, it also contains the global default address."
|
|
INDEX { cadSysSourceAddressIndex }
|
|
::= { cadSysSourceAddressTable 1 }
|
|
|
|
CadSysSourceAddressEntry ::= SEQUENCE {
|
|
cadSysSourceAddressIndex AdminSrcAddrType,
|
|
cadSysSourceInterfaceIpv4IfIndex InterfaceIndexOrZero,
|
|
cadSysSourceAddressIpv4Address InetAddressIPv4,
|
|
cadSysSourceInterfaceIpv6IfIndex InterfaceIndexOrZero,
|
|
cadSysSourceAddressIpv6Address InetAddressIPv6
|
|
}
|
|
|
|
cadSysSourceAddressIndex OBJECT-TYPE
|
|
SYNTAX AdminSrcAddrType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of administrative service."
|
|
::= { cadSysSourceAddressEntry 1 }
|
|
|
|
cadSysSourceInterfaceIpv4IfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of the interface from which all IPv4 packets are sourced.
|
|
For a server service, it is also the only DIP allowed for incoming requests.
|
|
A value of 0 indicates no source interface override."
|
|
DEFVAL { 0 }
|
|
::= { cadSysSourceAddressEntry 2 }
|
|
|
|
cadSysSourceAddressIpv4Address OBJECT-TYPE
|
|
SYNTAX InetAddressIPv4
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPv4 address of the IPv4 interface at the time the row ipv4 ifIndex was populated.
|
|
Used as the source address for the service if the state is in-service.
|
|
For a server service, it is also the only DIP allowed for incoming requests.
|
|
A value of null indicates no source address has been assigned."
|
|
|
|
DEFVAL { "" }
|
|
::= { cadSysSourceAddressEntry 3 }
|
|
|
|
|
|
cadSysSourceInterfaceIpv6IfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of the interface from which all IPv6 packets are sourced (not currently supported).
|
|
For a server service, it is also the only DIP allowed for incoming requests.
|
|
A value of 0 indicates no source interface override."
|
|
DEFVAL { 0 }
|
|
::= { cadSysSourceAddressEntry 4 }
|
|
|
|
cadSysSourceAddressIpv6Address OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPv6 address of the IPv6 interface
|
|
at the time the ipv6 ifIndex was populated.
|
|
Used as the source address for the service if the state is in-service.
|
|
For a server service, it is also the only DIP allowed for incoming requests.
|
|
A value of null indicates no source address has been assigned."
|
|
|
|
DEFVAL { "" }
|
|
::= { cadSysSourceAddressEntry 5}
|
|
|
|
--========================== License Control ==========================--
|
|
|
|
cadSysLicenseCardId OBJECT-TYPE
|
|
SYNTAX CardId
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CAM to be licensed."
|
|
DEFVAL { 0 }
|
|
::= { cadSysLicenseControl 1 }
|
|
|
|
cadSysLicenseKey OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (16))
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"License key to apply to the CAM."
|
|
DEFVAL { ''h }
|
|
::= { cadSysLicenseControl 2 }
|
|
|
|
cadSysLicensePorts OBJECT-TYPE
|
|
SYNTAX Integer32(0..5000)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of CAM ports associated with the license."
|
|
DEFVAL { 0 }
|
|
::= { cadSysLicenseControl 3 }
|
|
|
|
cadSysLicenseAnnex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
other(2),
|
|
annexA(3),
|
|
annexB(4),
|
|
annexC(5)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute defines the ITU-J-83 Annex being used
|
|
for this E6000 CMTS License."
|
|
DEFVAL { unknown }
|
|
::= { cadSysLicenseControl 4 }
|
|
|
|
cadSysLicenseStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
success(1),
|
|
fail(2),
|
|
pending(3),
|
|
none(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current status of licensing operation."
|
|
DEFVAL { none }
|
|
::= { cadSysLicenseControl 5 }
|
|
|
|
|
|
--============================ LAES Mediation Device Timestamp Mode Table ===========================
|
|
|
|
cadLaesMdTimestampModeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadLaesMdTimestampModeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of LAES Mediation Device Timestamp mode table"
|
|
::= { cadLaesMdTimestampMode 1 }
|
|
|
|
cadLaesMdTimestampModeEntry OBJECT-TYPE
|
|
SYNTAX CadLaesMdTimestampModeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This entry contains the configured MD IPv4.
|
|
If configured, then all encapsulated tap packets going to that MD will contain
|
|
a timestamp in the tap header."
|
|
INDEX { cadLaesMdTimestampModeInetAddrType, cadLaesMdTimestampModeInetAddr}
|
|
::= { cadLaesMdTimestampModeTable 1 }
|
|
|
|
CadLaesMdTimestampModeEntry ::= SEQUENCE {
|
|
cadLaesMdTimestampModeInetAddrType InetAddressType,
|
|
cadLaesMdTimestampModeInetAddr InetAddress,
|
|
cadLaesMdTimestampModRowStatus RowStatus
|
|
}
|
|
|
|
cadLaesMdTimestampModeInetAddrType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP Address type of Mediation Device"
|
|
::= { cadLaesMdTimestampModeEntry 1 }
|
|
|
|
cadLaesMdTimestampModeInetAddr OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP Address of the Mediation Device."
|
|
::= { cadLaesMdTimestampModeEntry 2 }
|
|
|
|
cadLaesMdTimestampModRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The row status of this entry"
|
|
::= { cadLaesMdTimestampModeEntry 3 }
|
|
|
|
---========================= cadSysMICSecondarySecretTable ==========================--
|
|
|
|
cadSysMICSecondarySecretTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadSysMICSecondarySecretEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table containing secondary shared secret strings for
|
|
cable modem configuration file authentication. This
|
|
table is not used unless cadSysMICEnable is set to
|
|
true."
|
|
::= { cadSysSharedSecret 1 }
|
|
|
|
cadSysMICSecondarySecretEntry OBJECT-TYPE
|
|
SYNTAX CadSysMICSecondarySecretEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry containing secondary shared secret strings for
|
|
cable modem configuration file authentication."
|
|
INDEX { cadSysMICSecondarySecretIndex }
|
|
::= { cadSysMICSecondarySecretTable 1 }
|
|
|
|
CadSysMICSecondarySecretEntry ::= SEQUENCE {
|
|
cadSysMICSecondarySecretIndex INTEGER,
|
|
cadSysMICSecondarySecretString OCTET STRING,
|
|
cadSysMICSecondarySecretStatus RowStatus
|
|
}
|
|
|
|
cadSysMICSecondarySecretIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..1)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Internal index for this MIB row."
|
|
::= { cadSysMICSecondarySecretEntry 1 }
|
|
|
|
cadSysMICSecondarySecretString OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..64))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Encrypted MIC Authentication shared secret string."
|
|
::= { cadSysMICSecondarySecretEntry 2 }
|
|
|
|
cadSysMICSecondarySecretStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of this conceptual row."
|
|
::= { cadSysMICSecondarySecretEntry 3 }
|
|
|
|
---
|
|
--- Conformance information
|
|
---
|
|
cadSystemMibConformance OBJECT IDENTIFIER ::= { cadSystemMib 12 }
|
|
cadSystemCompliances OBJECT IDENTIFIER ::= { cadSystemMibConformance 1 }
|
|
cadSystemGroups OBJECT IDENTIFIER ::= { cadSystemMibConformance 2 }
|
|
|
|
cadSystemCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Compliance statement for entities implementing the Cadant System Mib."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cadSysParamsGroup, cadSysSystemGroup,
|
|
cadSysControlGroup, cadSysSnmpGroup,
|
|
cadSysBootParamsGroup, cadSysReloadGroup,
|
|
cadSysImageGroup, cadSysDataServerGroup,
|
|
cadSysSourceAddressGroup }
|
|
|
|
::= { cadSystemCompliances 1 }
|
|
|
|
cadSysParamsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cadSysSyncInterval,
|
|
cadSysUCDInterval,
|
|
cadSysMaxMAPPending,
|
|
cadSysRangingInterval,
|
|
cadSysInvitedRangingRetries,
|
|
cadSysRegistrationRequestRetries,
|
|
cadSysCMMAPProcessingTime,
|
|
cadSysCMConfiguration,
|
|
cadSysT5Timeout,
|
|
cadSysT6Timeout,
|
|
cadSysMiniSlotSize,
|
|
cadSysDSxRequestRetries,
|
|
cadSysT7Timeout,
|
|
cadSysT8Timeout,
|
|
cadSysT9Timeout,
|
|
cadSysT10Timeout,
|
|
cadSysT11Timeout,
|
|
cadSysT13Timeout,
|
|
cadSysDCCREQRetries,
|
|
cadSysMICEnable,
|
|
cadSysMICAuthString,
|
|
cadSysAutoRecoveryEnable,
|
|
cadSysActiveIpAddress,
|
|
cadSysSpOperMode,
|
|
cadSysMaxQoSActiveTimeout,
|
|
cadSysMaxQoSAdmittedTimeout,
|
|
cadSysAllow10CmConcatenation,
|
|
cadSysAllow10CmFragmentation,
|
|
cadSysPercentAddtlDsBwAllocated,
|
|
cadSysMaxTrafBurstFor11CMs,
|
|
cadSysRemoteFSEnable,
|
|
cadSysRemotePortEnable,
|
|
cadSysTcpSmoothingValue1D8U,
|
|
cadSysTcpSmoothingValue2D12U,
|
|
cadSysModemLossThreshold,
|
|
cadSysPeakTrafRateFor11CMs,
|
|
cadSysCpeHostAuthorization
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System parameter objects"
|
|
::= { cadSystemGroups 1 }
|
|
|
|
cadSysSystemGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cadSysContact,
|
|
cadSysName,
|
|
cadSysLocation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System description objects"
|
|
::= { cadSystemGroups 2 }
|
|
|
|
cadSysControlGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cadSysWriteMem,
|
|
cadSysEraseMem
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"System control objects"
|
|
::= { cadSystemGroups 3 }
|
|
|
|
cadSysSnmpGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cadSysEnableAuthenTraps,
|
|
cadSysSnmpReadAheadMax,
|
|
cadSysSnmpRefreshTime
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System snmp control object"
|
|
::= { cadSystemGroups 4 }
|
|
|
|
cadSysBootParamsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cadSysBootMacAddress,
|
|
cadSysBootFpIpAddress,
|
|
cadSysBootFpSubnetMask,
|
|
cadSysBootDefaultGateway,
|
|
cadSysBootTimeOffset,
|
|
cadSysBootTimeServer,
|
|
cadSysBootTimeServerConnType,
|
|
cadSysBootStartupApplication,
|
|
cadSysBootStartupDelay,
|
|
cadSysBootSelection
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System boot parameters objects"
|
|
::= { cadSystemGroups 5 }
|
|
|
|
cadSysReloadGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cadSysReloadImageName,
|
|
cadSysReloadOperation,
|
|
cadSysReloadStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System reload control objects"
|
|
::= { cadSystemGroups 6 }
|
|
|
|
cadSysImageGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cadSysImageFile,
|
|
cadSysImageId,
|
|
cadSysImageName,
|
|
cadSysImageComponentCount
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System image status objects"
|
|
::= { cadSystemGroups 7 }
|
|
|
|
cadSysConfigurationGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cadSysConfigSaveTime
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configuration objects"
|
|
::= { cadSystemGroups 8 }
|
|
|
|
|
|
cadSysDataServerGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cadSysDataServerDataTimeout,
|
|
cadSysDataServerDataEventsPerCycle,
|
|
cadSysDataServerDataSyncTimeout,
|
|
cadSysDataServerSnmpReadAheadEnable,
|
|
cadSysDataServerSnmpReadAheadMax,
|
|
cadSysDataServerSnmpRefreshTime,
|
|
cadSysDataServerSyncDataEventsPerCycle,
|
|
cadSysDataServerLoPriDataEventsPerCycle
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configuration objects"
|
|
::= { cadSystemGroups 9 }
|
|
|
|
cadSysSourceAddressGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cadSysSourceInterfaceIpv4IfIndex,
|
|
cadSysSourceAddressIpv4Address,
|
|
cadSysSourceInterfaceIpv6IfIndex,
|
|
cadSysSourceAddressIpv6Address
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Source Interface objects."
|
|
::= { cadSystemGroups 10 }
|
|
|
|
END -- end of CADANT-CMTS-SYSTEM-MIB
|
|
|