CADANT-CMTS-SPECTRUM-MGMT-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter32, Unsigned32
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION, TruthValue, RowStatus, DateAndTime, DisplayString
|
|
FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
InterfaceIndex
|
|
FROM IF-MIB
|
|
cadIfUpstreamChannelEntry
|
|
FROM CADANT-CMTS-UPCHANNEL-MIB
|
|
TenthdB
|
|
FROM DOCS-IF-MIB
|
|
cadSpectrum
|
|
FROM CADANT-PRODUCTS-MIB;
|
|
|
|
cadSpMgtMib MODULE-IDENTITY
|
|
LAST-UPDATED "201304300000Z"
|
|
ORGANIZATION "Arris International Inc."
|
|
CONTACT-INFO
|
|
"Customer Support
|
|
|
|
Address: Arris Group Inc.
|
|
2400 E. Ogden Avenue, Suite 180
|
|
Lisle, IL 60532
|
|
|
|
Phone: +1 630 281 3000"
|
|
DESCRIPTION
|
|
"The MIB module describes the C4 Upstream Spectrum Management"
|
|
REVISION "201304300000Z"
|
|
DESCRIPTION "Support cadSpMgtStateFrequency up to 85MHz."
|
|
REVISION "201207030000Z"
|
|
DESCRIPTION "Added state change count in history entry."
|
|
REVISION "201207020000Z"
|
|
DESCRIPTION "Added cadSpMgtHistorySysUpTime in history entry."
|
|
REVISION "200602210000Z"
|
|
DESCRIPTION "Use cadSpMgtHistoryTime for index."
|
|
REVISION "200602060000Z"
|
|
DESCRIPTION "Added spectrum group id in history entry."
|
|
REVISION "200511100000Z"
|
|
DESCRIPTION "Initial version."
|
|
::= { cadSpectrum 4 }
|
|
|
|
cadSpMgtNotifications OBJECT IDENTIFIER ::= { cadSpMgtMib 1 }
|
|
cadSpMgtObjects OBJECT IDENTIFIER ::= { cadSpMgtMib 2 }
|
|
cadSpMgtConformance OBJECT IDENTIFIER ::= { cadSpMgtMib 3 }
|
|
cadSpMgtGroup OBJECT IDENTIFIER ::= { cadSpMgtObjects 1 }
|
|
cadSpMgtRequests OBJECT IDENTIFIER ::= { cadSpMgtObjects 2 }
|
|
|
|
|
|
|
|
--
|
|
-- Textual conventions
|
|
--
|
|
|
|
SpTriggerType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trigger is used to manage the state transition in C4
|
|
Upstream Spectrum Management State Machine. The trigger has the
|
|
following defined values:
|
|
|
|
TOD -
|
|
defined with <Time of Day> and reoccurring day within a week
|
|
|
|
Periodic -
|
|
defined with a period of time
|
|
|
|
degradation -
|
|
defined with 3 threshold value for the purpose of degradation
|
|
|
|
improvement -
|
|
defined with 3 threshold value for the purpose of improvement
|
|
|
|
"
|
|
SYNTAX INTEGER { tod(1),
|
|
periodic(2),
|
|
degradation(3),
|
|
improvement(4)
|
|
}
|
|
|
|
SpTriggerDay ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trigger day is to specify the reoccurrence of the TOD
|
|
trigger for a week.
|
|
|
|
The trigger day has the following defined values:
|
|
7: every day
|
|
0: Sunday
|
|
1: Monday
|
|
2: Tuesday
|
|
3: Wednesday
|
|
4: Thursday
|
|
5: Friday
|
|
6: Saturday"
|
|
|
|
SYNTAX INTEGER {
|
|
sunday(0),
|
|
monday(1),
|
|
tuesday(2),
|
|
wednesday(3),
|
|
thursday(4),
|
|
friday(5),
|
|
saturday(6),
|
|
everyday(7)
|
|
}
|
|
|
|
SpTimeOfDay ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "1d:1d:1d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A time-of-day specification in hours:minutes:seconds.
|
|
|
|
field octets contents range
|
|
----- ------ -------- -----
|
|
1 1 hour 0..23
|
|
2 1 minutes 0..59
|
|
3 1 seconds 0..59"
|
|
SYNTAX OCTET STRING (SIZE (3))
|
|
|
|
Unsigned16 ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An unsigned 16 bit integer."
|
|
SYNTAX Unsigned32 (0..65535)
|
|
|
|
--
|
|
-- Upstream Spectrum Management Group Table
|
|
--
|
|
|
|
cadSpMgtGroupTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadSpMgtGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry in this table defines a C4 Upstream Spectrum
|
|
Management group."
|
|
::= { cadSpMgtGroup 1 }
|
|
|
|
cadSpMgtGroupEntry OBJECT-TYPE
|
|
SYNTAX CadSpMgtGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A set of C4 Upstream Spectrum Management group information.
|
|
Entries in the cadSpMgtGroupTable are created and
|
|
deleted using the cadSpMgtGroupRowStatus object."
|
|
INDEX { cadSpMgtGroupIndex }
|
|
::= { cadSpMgtGroupTable 1 }
|
|
|
|
CadSpMgtGroupEntry ::=
|
|
SEQUENCE {
|
|
cadSpMgtGroupIndex Integer32,
|
|
cadSpMgtGroupSamplePeriod Integer32,
|
|
cadSpMgtGroupHopPeriod Integer32,
|
|
cadSpMgtGroupCodeword Integer32,
|
|
cadSpMgtGroupRetryPeriod Integer32,
|
|
cadSpMgtGroupEnabled TruthValue,
|
|
cadSpMgtGroupRowStatus RowStatus
|
|
}
|
|
|
|
cadSpMgtGroupIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..40)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index used to identify the Upstream Spectrum Group."
|
|
::= { cadSpMgtGroupEntry 1 }
|
|
|
|
cadSpMgtGroupSamplePeriod OBJECT-TYPE
|
|
SYNTAX Integer32 (0..60)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time (in seconds) between samples used for the degradation
|
|
and the improvement triggers."
|
|
DEFVAL { 4 }
|
|
::= { cadSpMgtGroupEntry 2 }
|
|
|
|
cadSpMgtGroupHopPeriod OBJECT-TYPE
|
|
SYNTAX Integer32 (0..3600)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum period of time (in seconds) that must pass between
|
|
successive state transitions."
|
|
DEFVAL { 1200 }
|
|
::= { cadSpMgtGroupEntry 3 }
|
|
|
|
cadSpMgtGroupCodeword OBJECT-TYPE
|
|
SYNTAX Integer32 (100..32768)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum number of codewords that must have been transmitted
|
|
on the upstream channel before the degradation and improvement
|
|
triggers are considered to be valid."
|
|
DEFVAL { 256 }
|
|
::= { cadSpMgtGroupEntry 4 }
|
|
|
|
cadSpMgtGroupRetryPeriod OBJECT-TYPE
|
|
SYNTAX Integer32 (1..604800)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the minimum wait time (in seconds)
|
|
before the retry is attempted. The retry-period timer controls
|
|
how quickly the state machine is allowed to retry when
|
|
transition failure occurred."
|
|
DEFVAL { 86400 }
|
|
::= { cadSpMgtGroupEntry 5 }
|
|
|
|
cadSpMgtGroupEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows for the optional enabling and disabling of a
|
|
spectrum group."
|
|
DEFVAL { true }
|
|
::= { cadSpMgtGroupEntry 6 }
|
|
|
|
cadSpMgtGroupRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of this conceptual row. To create a row in this
|
|
table, set this object to createAndGo(4). Support of the values
|
|
includes createAndGo(4) and destroy(6)"
|
|
::= { cadSpMgtGroupEntry 7 }
|
|
|
|
--
|
|
-- Upstream Spectrum Management State Table
|
|
--
|
|
|
|
cadSpMgtStateTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadSpMgtStateEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry in this table defines a state used for C4 Upstream
|
|
Spectrum Management."
|
|
::= { cadSpMgtGroup 2 }
|
|
|
|
cadSpMgtStateEntry OBJECT-TYPE
|
|
SYNTAX CadSpMgtStateEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A set of Upstream Spectrum Management state information.
|
|
Entries in the cadSpMgtStateTable are created and
|
|
deleted using the cadSpMgtStateRowStatus object."
|
|
INDEX { cadSpMgtGroupIndex, cadSpMgtStateIndex }
|
|
::= { cadSpMgtStateTable 1 }
|
|
|
|
CadSpMgtStateEntry ::=
|
|
SEQUENCE {
|
|
cadSpMgtStateIndex Integer32,
|
|
cadSpMgtStateFrequency Integer32,
|
|
cadSpMgtStateWidth Integer32,
|
|
cadSpMgtStateModulationProfile Unsigned32,
|
|
cadSpMgtStateRowStatus RowStatus
|
|
}
|
|
|
|
cadSpMgtStateIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..16)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index used to identify the state in C4 Upstream Spectrum
|
|
Management."
|
|
::= { cadSpMgtStateEntry 1 }
|
|
|
|
cadSpMgtStateFrequency OBJECT-TYPE
|
|
SYNTAX Integer32 (0 | 5000000..85000000)
|
|
UNITS "hertz"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The center of the frequency band for the upstream channel
|
|
associated with this state."
|
|
DEFVAL { 0 }
|
|
::= { cadSpMgtStateEntry 2 }
|
|
|
|
cadSpMgtStateWidth OBJECT-TYPE
|
|
SYNTAX Integer32 (0..6400000)
|
|
UNITS "hertz"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bandwidth for the upstream channel associated with this
|
|
state."
|
|
DEFVAL { 0 }
|
|
::= { cadSpMgtStateEntry 3 }
|
|
|
|
cadSpMgtStateModulationProfile OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry identical to the docsIfModIndex in the
|
|
docsIfCmtsModulationTable that describes the upstream channel
|
|
associated with this state."
|
|
DEFVAL { 0 }
|
|
::= { cadSpMgtStateEntry 4 }
|
|
|
|
cadSpMgtStateRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of this conceptual row. To create a row in this
|
|
table, set this object to createAndGo(4). Support of the
|
|
values includes createAndGo(4) and destroy(6)"
|
|
::= { cadSpMgtStateEntry 5 }
|
|
|
|
--
|
|
-- Upstream Spectrum Management trigger table
|
|
--
|
|
|
|
cadSpMgtTriggerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadSpMgtTriggerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry in this table defines a trigger for C4 Upstream
|
|
Spectrum Management"
|
|
::= { cadSpMgtGroup 3 }
|
|
|
|
cadSpMgtTriggerEntry OBJECT-TYPE
|
|
SYNTAX CadSpMgtTriggerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A set of Upstream Spectrum Management trigger information.
|
|
Entries in the cadSpMgtTriggerTable are created and
|
|
deleted using the cadSpMgtTriggerRowStatus object."
|
|
INDEX { cadSpMgtTriggerIndex }
|
|
::= { cadSpMgtTriggerTable 1 }
|
|
|
|
CadSpMgtTriggerEntry ::=
|
|
SEQUENCE {
|
|
cadSpMgtTriggerIndex Integer32,
|
|
cadSpMgtTriggerType SpTriggerType,
|
|
cadSpMgtTriggerDay SpTriggerDay,
|
|
cadSpMgtTriggerTOD SpTimeOfDay,
|
|
cadSpMgtTriggerPeriod Integer32,
|
|
cadSpMgtTriggerThres1 Unsigned32,
|
|
cadSpMgtTriggerThres2 Unsigned32,
|
|
cadSpMgtTriggerThres3 TenthdB,
|
|
cadSpMgtTriggerRowStatus RowStatus
|
|
}
|
|
|
|
cadSpMgtTriggerIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..64)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trigger index used to identify the trigger for each state
|
|
transition."
|
|
::= { cadSpMgtTriggerEntry 1 }
|
|
|
|
cadSpMgtTriggerType OBJECT-TYPE
|
|
SYNTAX SpTriggerType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trigger type."
|
|
DEFVAL { degradation }
|
|
::= { cadSpMgtTriggerEntry 2 }
|
|
|
|
cadSpMgtTriggerDay OBJECT-TYPE
|
|
SYNTAX SpTriggerDay
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trigger day is to specify the reoccurrence of the TOD
|
|
trigger for a week. The trigger day has the following defined
|
|
values:
|
|
0: Sunday
|
|
1: Monday
|
|
2: Tuesday
|
|
3: Wednesday
|
|
4: Thursday
|
|
5: Friday
|
|
6: Saturday
|
|
7: Everyday
|
|
"
|
|
::= { cadSpMgtTriggerEntry 3 }
|
|
|
|
cadSpMgtTriggerTOD OBJECT-TYPE
|
|
SYNTAX SpTimeOfDay
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time of day to transition to next state, in HH:MM:SS format"
|
|
DEFVAL { '000000'h }
|
|
::= { cadSpMgtTriggerEntry 4 }
|
|
|
|
cadSpMgtTriggerPeriod OBJECT-TYPE
|
|
SYNTAX Integer32 (1..604800)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time that should be loaded into a timer, in
|
|
seconds, once the state machine has transitioned into the
|
|
associated current state. When the timer expires, the transition
|
|
to next state defined in the state machine is executed. This
|
|
value is an integer between 1 and 604,800 (which covers a period
|
|
of a week). This object is applicable for trigger type of
|
|
periodic(2)"
|
|
::= { cadSpMgtTriggerEntry 5 }
|
|
|
|
cadSpMgtTriggerThres1 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..100000)
|
|
UNITS "0.001 percentage"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is applicable for trigger type of degradation (3)
|
|
and improvement (4).
|
|
For degradation trigger, this is the maximum acceptable
|
|
percentage of FEC errors (uncorrectable plus correctable).
|
|
For improvement trigger, this is the minimum acceptable
|
|
percentage of FEC errors (uncorrectable plus correctable)"
|
|
DEFVAL { 0 }
|
|
::= { cadSpMgtTriggerEntry 6 }
|
|
|
|
cadSpMgtTriggerThres2 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..100000)
|
|
UNITS "0.001 percentage"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is applicable for trigger type of degradation (3)
|
|
and improvement (4).
|
|
For degradation trigger, this is the maximum acceptable
|
|
percentage of uncorrectable FEC errors.
|
|
For improvement trigger, this is the minimum acceptable
|
|
percentage of uncorrectable FEC errors."
|
|
DEFVAL { 0 }
|
|
::= { cadSpMgtTriggerEntry 7 }
|
|
|
|
cadSpMgtTriggerThres3 OBJECT-TYPE
|
|
SYNTAX TenthdB (0..1000)
|
|
UNITS "dB"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is applicable for trigger type of degradation (3)
|
|
and improvement (4).
|
|
For degradation trigger, this is the minimum acceptable
|
|
Signal/Noise ratio (in dB).
|
|
For improvement trigger, this is the maximum acceptable
|
|
Signal/Noise ratio (in dB). "
|
|
DEFVAL { 1000 }
|
|
::= { cadSpMgtTriggerEntry 8 }
|
|
|
|
cadSpMgtTriggerRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of this conceptual row. To create a row in this
|
|
table, set this object to createAndGo(4). Support of the values
|
|
includes createAndGo(4) and destroy(6)"
|
|
::= { cadSpMgtTriggerEntry 9 }
|
|
|
|
--
|
|
-- Upstream Spectrum Management State Transition Table
|
|
--
|
|
|
|
cadSpMgtStateTransTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadSpMgtStateTransEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry in this table defines the state machine in C4 Upstream Spectrum Management."
|
|
::= { cadSpMgtGroup 4 }
|
|
|
|
cadSpMgtStateTransEntry OBJECT-TYPE
|
|
SYNTAX CadSpMgtStateTransEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { cadSpMgtGroupIndex, cadSpMgtStateIndex, cadSpMgtTriggerIndex }
|
|
::= { cadSpMgtStateTransTable 1 }
|
|
|
|
CadSpMgtStateTransEntry ::=
|
|
SEQUENCE {
|
|
cadSpMgtTransNextState Integer32,
|
|
cadSpMgtStateTransRowStatus RowStatus
|
|
}
|
|
|
|
cadSpMgtTransNextState OBJECT-TYPE
|
|
SYNTAX Integer32 (1..16)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index used to identify the next state to which the state
|
|
machine may transition to as a result of this trigger."
|
|
::= { cadSpMgtStateTransEntry 1 }
|
|
|
|
cadSpMgtStateTransRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of this conceptual row. To create a row in this
|
|
table, set this object to createAndGo(4). Support of the values
|
|
includes createAndGo(4) and destroy(6)"
|
|
::= { cadSpMgtStateTransEntry 2 }
|
|
|
|
cadSpMgtRequestUpChannelIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IfIndex of the upstream channel."
|
|
::= { cadSpMgtRequests 1 }
|
|
|
|
cadSpMgtRequestTriggerIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trigger index used to identify the trigger. A value of 0
|
|
indicates no trigger is attempted."
|
|
::= { cadSpMgtRequests 2 }
|
|
|
|
cadSpMgtRequestNextState OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index used to identify the next state to which the state
|
|
machine may transition to."
|
|
::= { cadSpMgtRequests 3 }
|
|
|
|
cadSpMgtRequestSNR OBJECT-TYPE
|
|
SYNTAX TenthdB
|
|
UNITS "dB"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the measured Signal/Noise ratio (in dB) for the
|
|
upstream channel. This object is applicable when the value in
|
|
cadSpMgtRequestTriggerIndex defines the trigger of type
|
|
degradation or improvement."
|
|
::= { cadSpMgtRequests 4 }
|
|
|
|
cadSpMgtRequestUFecError OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..100000)
|
|
UNITS "0.001 percentage"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the measured percentage of uncorrectable
|
|
FEC errors for the upstream channel.
|
|
This object is applicable when the value in
|
|
cadSpMgtRequestTriggerIndex defines the trigger of type
|
|
degradation or improvement."
|
|
::= { cadSpMgtRequests 5 }
|
|
|
|
cadSpMgtRequestFecError OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..100000)
|
|
UNITS "0.001 percentage"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the measured percentage of FEC errors
|
|
(uncorrectable plus correctable) for the upstream channel.
|
|
This object is applicable when the value in
|
|
cadSpMgtRequestTriggerIndex defines the trigger of type
|
|
degradation or improvement."
|
|
::= { cadSpMgtRequests 6 }
|
|
|
|
cadSpMgtRequestCommit OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The command to execute the request when set to
|
|
true(1).
|
|
The following are reasons for rejecting an SNMP
|
|
SET to this object:
|
|
- An operation is commited for a non-existing upstream channel ID or the corresponding ifOperStatus is down(2).
|
|
- An operation is committed but cadSpMgtRequestNextState is not an existing state index in cadSpMgtStateEntry.
|
|
- An operation is committed but the value in cadSpMgtRequestTriggerIndex is non-zero and not an existing trigger index in cadSpMgtTriggerEntry.
|
|
Reading this object always returns false(2)."
|
|
DEFVAL {false}
|
|
::= { cadSpMgtRequests 7 }
|
|
|
|
--
|
|
-- Upstream Spectrum Management History Table
|
|
--
|
|
|
|
cadSpMgtHistoryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadSpMgtHistoryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of state transition history."
|
|
::= { cadSpMgtGroup 5 }
|
|
|
|
cadSpMgtHistoryEntry OBJECT-TYPE
|
|
SYNTAX CadSpMgtHistoryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry of state transition history."
|
|
INDEX { cadSpMgtHistoryUpChannelIfIndex, cadSpMgtHistoryTime }
|
|
::= { cadSpMgtHistoryTable 1 }
|
|
|
|
CadSpMgtHistoryEntry::=
|
|
SEQUENCE {
|
|
cadSpMgtHistoryUpChannelIfIndex InterfaceIndex,
|
|
cadSpMgtHistoryTime DateAndTime,
|
|
cadSpMgtHistoryTriggerIndex Integer32,
|
|
cadSpMgtHistoryFromStateIndex Integer32,
|
|
cadSpMgtHistoryNextStateIndex Integer32,
|
|
cadSpMgtHistoryResultStateIndex Integer32,
|
|
cadSpMgtHistorySNR TenthdB,
|
|
cadSpMgtHistoryUFecError Unsigned32,
|
|
cadSpMgtHistoryFecError Unsigned32,
|
|
cadSpMgtHistorySpareCardId Integer32,
|
|
cadSpMgtHistoryText DisplayString,
|
|
cadSpMgtHistoryGroupId Integer32,
|
|
cadSpMgtHistoryStateChangeCount Unsigned16,
|
|
cadSpMgtHistorySysUpTime Unsigned32
|
|
}
|
|
|
|
cadSpMgtHistoryUpChannelIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IfIndex of the upstream channel."
|
|
::= { cadSpMgtHistoryEntry 1 }
|
|
|
|
cadSpMgtHistoryTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is the actual clock time
|
|
when this entry was created."
|
|
::= { cadSpMgtHistoryEntry 2 }
|
|
|
|
cadSpMgtHistoryTriggerIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trigger index used to identify the trigger for state
|
|
transition. A value of 0 indicates a manual trigger."
|
|
::= { cadSpMgtHistoryEntry 3 }
|
|
|
|
cadSpMgtHistoryFromStateIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index used to identify the current state."
|
|
::= { cadSpMgtHistoryEntry 4 }
|
|
|
|
cadSpMgtHistoryNextStateIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index used to identify the next state to which the state
|
|
machine may transition to."
|
|
::= { cadSpMgtHistoryEntry 5 }
|
|
|
|
cadSpMgtHistoryResultStateIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index used to identify the result state to which the state
|
|
machine has transitioned to. For a successful state transition
|
|
request, the value of this object is the same as
|
|
cadSpMgtHistoryNextState."
|
|
::= { cadSpMgtHistoryEntry 6 }
|
|
|
|
cadSpMgtHistorySNR OBJECT-TYPE
|
|
SYNTAX TenthdB
|
|
UNITS "dB"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the measured Signal/Noise ratio (in dB) for the
|
|
upstream channel. This object is applicable when the value in
|
|
cadSpMgtHistoryTriggerIndex defines the trigger of type
|
|
degradation or improvement."
|
|
::= { cadSpMgtHistoryEntry 7 }
|
|
|
|
cadSpMgtHistoryUFecError OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..100000)
|
|
UNITS "0.001 percentage"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the measured percentage of uncorrectable
|
|
FEC errors for the upstream channel. This object is applicable
|
|
when the value in cadSpMgtHistoryTriggerIndex defines the trigger
|
|
of type degradation or improvement."
|
|
::= { cadSpMgtHistoryEntry 8 }
|
|
|
|
cadSpMgtHistoryFecError OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..100000)
|
|
UNITS "0.001 percentage"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the measured percentage of FEC errors
|
|
(uncorrectable plus correctable) for the upstream channel.
|
|
This object is applicable when the value in
|
|
cadSpMgtHistoryTriggerIndex defines the trigger of type
|
|
degradation or improvement."
|
|
::= { cadSpMgtHistoryEntry 9 }
|
|
|
|
cadSpMgtHistorySpareCardId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..99)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The cardId of the spare CAM. The value of 0 indicates the
|
|
CAM is not spared at the time the request is received."
|
|
::= { cadSpMgtHistoryEntry 10 }
|
|
|
|
cadSpMgtHistoryText OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object provides a human-readable description of the entry,
|
|
including all relevant context."
|
|
::= { cadSpMgtHistoryEntry 11 }
|
|
|
|
cadSpMgtHistoryGroupId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Upstream Spectrum Group index associated with the upstream channel."
|
|
::= { cadSpMgtHistoryEntry 12 }
|
|
|
|
cadSpMgtHistoryStateChangeCount OBJECT-TYPE
|
|
SYNTAX Unsigned16
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides the count of state changes in the history entry. This object will
|
|
always increase. It is 16 bits, once it is at 0xffff, the counter will roll
|
|
over and start from beginning."
|
|
::= { cadSpMgtHistoryEntry 13 }
|
|
|
|
cadSpMgtHistorySysUpTime OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides the system up time in the history entry. This object will
|
|
always increase."
|
|
::= { cadSpMgtHistoryEntry 14 }
|
|
|
|
--
|
|
-- Upstream Spectrum Management History Table
|
|
--
|
|
|
|
cadSpMgtUpChannelTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadSpMgtUpChannelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table describes Upstream Frequency Agility attributes of
|
|
attached upstream channels."
|
|
::= { cadSpMgtGroup 6 }
|
|
|
|
cadSpMgtUpChannelEntry OBJECT-TYPE
|
|
SYNTAX CadSpMgtUpChannelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The List of Upstream Frequency Agility attributes associated with
|
|
an upstream channel."
|
|
AUGMENTS { cadIfUpstreamChannelEntry }
|
|
::= { cadSpMgtUpChannelTable 1 }
|
|
|
|
CadSpMgtUpChannelEntry ::= SEQUENCE {
|
|
cadSpMgtUpChannelCurrState Integer32,
|
|
cadSpMgtUpChannelStateTransTime DateAndTime
|
|
}
|
|
|
|
cadSpMgtUpChannelCurrState OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current state as a result of the upstream spectrum group
|
|
state transition. This object is only applicable if upstream
|
|
spectrum management is enabled for this upstream channel."
|
|
REFERENCE
|
|
"C4 CMTS Upstream Frequency Agility"
|
|
::= { cadSpMgtUpChannelEntry 1 }
|
|
|
|
cadSpMgtUpChannelStateTransTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is the actual clock time when the current
|
|
state information in cadIfUpChannelSpGroupCurrState is most
|
|
recently updated."
|
|
::= { cadSpMgtUpChannelEntry 2 }
|
|
END
|