-- Copyright (C) 2006-2012 Aricent Group . All Rights Reserved
|
|
|
|
-- $Id: fsfm.mib,v 1.6 2013/11/05 10:57:52 siva Exp $
|
|
|
|
-- Fault Management Proprietary MIB Definition
|
|
|
|
-- This MIB contains tables used to configure a switch running FM
|
|
|
|
|
|
FM-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE,
|
|
enterprises, Integer32, Unsigned32 FROM SNMPv2-SMI
|
|
DisplayString FROM SNMPv2-TC
|
|
ifIndex FROM IF-MIB;
|
|
|
|
|
|
fsfm MODULE-IDENTITY
|
|
LAST-UPDATED "201209050000Z"
|
|
ORGANIZATION "ARICENT COMMUNICATIONS SOFTWARE"
|
|
CONTACT-INFO "support@aricent.com"
|
|
DESCRIPTION
|
|
" The proprietary MIB module for FM module. "
|
|
REVISION "201209050000Z"
|
|
DESCRIPTION
|
|
" The proprietary MIB module for FM module. "
|
|
::= { enterprises futuresoftware (2076) 122 }
|
|
|
|
|
|
-- ------------------------------------------------------------
|
|
-- groups in the MIB
|
|
-- ------------------------------------------------------------
|
|
|
|
fsFmSystem OBJECT IDENTIFIER ::= { fsfm 1 }
|
|
fsFmLinkEvent OBJECT IDENTIFIER ::= { fsfm 2 }
|
|
fsFmLoopback OBJECT IDENTIFIER ::= { fsfm 3 }
|
|
fsFmVarRetrieval OBJECT IDENTIFIER ::= { fsfm 4 }
|
|
|
|
fsFmSystemControl OBJECT-TYPE
|
|
SYNTAX INTEGER { start(1),
|
|
shutdown(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fault Management module is shutdown or started through
|
|
this object.
|
|
When set to 'start', resources required by the
|
|
FM module is allocated and the module starts running.
|
|
When set to 'shutdown', all the resources are released back
|
|
to the system and the module stops running."
|
|
DEFVAL { shutdown }
|
|
::= { fsFmSystem 1 }
|
|
|
|
fsFmModuleStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { enabled(1),
|
|
disabled(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The module status of the Fault Management module.
|
|
The value enabled(1) indicates the Fault Management module
|
|
is currently enabled in the system.
|
|
The value disabled(2) indicates the Fault Management module
|
|
is currently disabled in the system."
|
|
DEFVAL { disabled }
|
|
::= { fsFmSystem 2 }
|
|
|
|
fsFmTraceOption OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to enable trace statements in
|
|
Fault Management module.
|
|
A four byte integer is used for enabling the trace level.
|
|
Each bit in the four byte integer represents a particular
|
|
trace level.
|
|
The mapping between the bit positions & the trace level is
|
|
as follows:
|
|
Bit 0 - Init and Shutdown traces
|
|
Bit 1 - Management traces
|
|
Bit 2 - Reserved
|
|
Bit 3 - Control plane traces
|
|
Bit 4 - Packet Dump traces
|
|
Bit 5 - Traces related to all resources except buffers
|
|
Bit 6 - All Failure traces
|
|
Bit 7 - Buffer allocation/release traces
|
|
|
|
Bit 16 - Function Entry traces
|
|
Bit 17 - Function exit traces
|
|
Bit 18 - Critical traces
|
|
Bit 19 - Remote Loopback test
|
|
Bit 20 - Fault Event trigger traces
|
|
Bit 21 - Event reception traces
|
|
Bit 22 - Variable request/response traces
|
|
|
|
The remaining bits are unused. Combination of levels are
|
|
also allowed.
|
|
|
|
For example if the bits 19 and 20 are set, then the trace
|
|
statement related to remote loopback test and event trigger
|
|
trace messages will be printed.
|
|
|
|
The user has to enter the corresponding integer value for the
|
|
bits set. For example if bits 8 and 9 are to be set, then user
|
|
has to give the value 0x300."
|
|
|
|
DEFVAL { '00040000'H }
|
|
::= { fsFmSystem 3 }
|
|
|
|
-- ------------------------------------------------------------------
|
|
-- The FM Link Event Group
|
|
-- ------------------------------------------------------------------
|
|
|
|
fsFmLinkEventTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsFmLinkEventEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains objects to configure Link Events
|
|
on the interfaces."
|
|
::= { fsFmLinkEvent 1 }
|
|
|
|
fsFmLinkEventEntry OBJECT-TYPE
|
|
SYNTAX FsFmLinkEventEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains action to be taken for each link
|
|
event."
|
|
INDEX { ifIndex }
|
|
::= { fsFmLinkEventTable 1 }
|
|
|
|
FsFmLinkEventEntry ::= SEQUENCE {
|
|
fsFmSymPeriodAction INTEGER,
|
|
fsFmFrameAction INTEGER,
|
|
fsFmFramePeriodAction INTEGER,
|
|
fsFmFrameSecSummAction INTEGER,
|
|
fsFmCriticalEventAction INTEGER,
|
|
fsFmDyingGaspAction INTEGER,
|
|
fsFmLinkFaultAction INTEGER
|
|
}
|
|
|
|
fsFmSymPeriodAction OBJECT-TYPE
|
|
SYNTAX INTEGER { none (1),
|
|
warning (2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Action to be taken when a Symbol Period Event Notification
|
|
is received.
|
|
'none' specifies no action will be taken when this event
|
|
is received.
|
|
'warning' specifies that a syslog message will be generated
|
|
when this event is received."
|
|
DEFVAL { warning }
|
|
::= { fsFmLinkEventEntry 1 }
|
|
|
|
fsFmFrameAction OBJECT-TYPE
|
|
SYNTAX INTEGER { none (1),
|
|
warning (2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Action to be taken when a Frame Event Notification
|
|
is received.
|
|
'none' specifies no action will be taken when this event
|
|
is received.
|
|
'warning' specifies that a syslog message will be generated
|
|
when this event is received."
|
|
DEFVAL { warning }
|
|
::= { fsFmLinkEventEntry 2 }
|
|
|
|
fsFmFramePeriodAction OBJECT-TYPE
|
|
SYNTAX INTEGER { none (1),
|
|
warning (2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Action to be taken when a Frame Period Event Notification
|
|
is received.
|
|
'none' specifies no action will be taken when this event
|
|
is received.
|
|
'warning' specifies that a syslog message will be generated
|
|
when this event is received."
|
|
DEFVAL { warning }
|
|
::= { fsFmLinkEventEntry 3 }
|
|
|
|
fsFmFrameSecSummAction OBJECT-TYPE
|
|
SYNTAX INTEGER { none (1),
|
|
warning (2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Action to be taken when a Frame Seconds summary Event
|
|
Notification is received.
|
|
'none' specifies no action will be taken when this event
|
|
is received.
|
|
'warning' specifies that a syslog message will be generated
|
|
when this event is received."
|
|
DEFVAL { warning }
|
|
::= { fsFmLinkEventEntry 4 }
|
|
|
|
fsFmCriticalEventAction OBJECT-TYPE
|
|
SYNTAX INTEGER { none (1),
|
|
warning (2),
|
|
block (3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Action to be taken when a Critical Event occurs at the
|
|
local interface and notification is received from
|
|
remote interface.
|
|
'none' specifies no action will be taken when this event
|
|
is received.
|
|
'warning' specifies that a syslog message will be generated
|
|
when this event is received.
|
|
'block' specifies that block the data tarffic except the OAM
|
|
PDU when this event is received."
|
|
DEFVAL { warning }
|
|
::= { fsFmLinkEventEntry 5 }
|
|
|
|
fsFmDyingGaspAction OBJECT-TYPE
|
|
SYNTAX INTEGER { none (1),
|
|
warning (2),
|
|
block (3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Action to be taken when a Dying Gasp event occurs at the
|
|
local interface and notification is received from
|
|
remote interface.
|
|
'none' specifies no action will be taken when this event
|
|
is received.
|
|
'warning' specifies that a syslog message will be generated
|
|
when this event is received.
|
|
'block' specifies that block the data tarffic except the OAM
|
|
PDU when this event is received."
|
|
DEFVAL { warning }
|
|
::= { fsFmLinkEventEntry 6 }
|
|
|
|
fsFmLinkFaultAction OBJECT-TYPE
|
|
SYNTAX INTEGER { none (1),
|
|
warning (2),
|
|
block (3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Action to be taken when a Link Fault Event occurs at the
|
|
local interface and notification is received from
|
|
remote interface.
|
|
'none' specifies no action will be taken when this event
|
|
is received.
|
|
'warning' specifies that a syslog message will be generated
|
|
when this event is received.
|
|
'block' specifies that block the data tarffic except the OAM
|
|
PDU when this event is received."
|
|
DEFVAL { warning }
|
|
::= { fsFmLinkEventEntry 7 }
|
|
|
|
-- ------------------------------------------------------------------
|
|
-- The FM Loopback Group
|
|
-- ------------------------------------------------------------------
|
|
|
|
-- Loopback test configuration and current statistics table
|
|
fsFmLoopbackTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsFmLoopbackEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains objects to configure Remote Loopback
|
|
mode and loopback tests."
|
|
::= { fsFmLoopback 1 }
|
|
|
|
fsFmLoopbackEntry OBJECT-TYPE
|
|
SYNTAX FsFmLoopbackEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains remote loopback configuration and
|
|
loopback test configuration."
|
|
INDEX { ifIndex }
|
|
::= { fsFmLoopbackTable 1 }
|
|
|
|
FsFmLoopbackEntry ::= SEQUENCE {
|
|
fsFmLoopbackStatus INTEGER,
|
|
fsFmLBTestPattern OCTET STRING,
|
|
fsFmLBTestPktSize Unsigned32,
|
|
fsFmLBTestCount Unsigned32,
|
|
fsFmLBTestWaitTime Integer32,
|
|
fsFmLBTestCommand INTEGER,
|
|
fsFmLBTestStatus INTEGER,
|
|
fsFmLBTestStartTimestamp DisplayString,
|
|
fsFmLBTestEndTimestamp DisplayString,
|
|
fsFmLBTestTxCount Unsigned32,
|
|
fsFmLBTestRxCount Unsigned32,
|
|
fsFmLBTestMatchCount Unsigned32
|
|
}
|
|
|
|
fsFmLoopbackStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { noLoopback (1),
|
|
remoteLoopback (2),
|
|
unknown (3) }
|
|
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The loopback status of the local interface. This status is
|
|
obtained from the local EOAM Client. When operating in
|
|
normal mode with no loopback in progress, the status reads
|
|
noLoopback(1).
|
|
If the local OAM client knows that the remote OAM entity is in
|
|
loopback mode , the status is remoteLoopback(2).
|
|
The unknown(3) status indicates the loopback status is not
|
|
known."
|
|
DEFVAL { unknown }
|
|
::= { fsFmLoopbackEntry 1 }
|
|
|
|
fsFmLBTestPattern OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test Pattern for the remote loopback test. The default pattern
|
|
of the test data will be 'F0F0F0F0'H "
|
|
::= { fsFmLoopbackEntry 2 }
|
|
|
|
fsFmLBTestPktSize OBJECT-TYPE
|
|
SYNTAX Unsigned32 (64..1500)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test packet size for the remote loopback test"
|
|
DEFVAL { 64 }
|
|
::= { fsFmLoopbackEntry 3 }
|
|
|
|
fsFmLBTestCount OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..1000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of Test packets to be sent for the remote
|
|
loopback test"
|
|
DEFVAL { 10 }
|
|
::= { fsFmLoopbackEntry 4 }
|
|
|
|
fsFmLBTestWaitTime OBJECT-TYPE
|
|
SYNTAX Integer32 (1..10)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This timer is started after sending the last test packet.
|
|
The Fault management module will wait until this timer
|
|
expires or the packet reception counter is equal to the
|
|
transmission counter. This timer (in seconds) denotes the
|
|
maximum time a packet can take to get looped back."
|
|
DEFVAL { 5 }
|
|
::= { fsFmLoopbackEntry 5 }
|
|
|
|
|
|
fsFmLBTestCommand OBJECT-TYPE
|
|
SYNTAX INTEGER { noLoopbackTest(1),
|
|
startLoopbackTest(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute initiates remote loopback test with
|
|
an EOAM peer. Writing startLoopbackTest(2) to this attribute
|
|
cause the fault management send loopback test packets with
|
|
defined test pattern, size and count.
|
|
Writing noLoopbackTest to this attribute has no effect.
|
|
|
|
Writes to this attribute are ignored unless the fsFmLoopbackStatus
|
|
of this interface is 'remoteLoopback'.
|
|
|
|
The attribute always returns noLoopbackTest on a read.
|
|
"
|
|
::= { fsFmLoopbackEntry 6 }
|
|
|
|
fsFmLBTestStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { notInitiated(1),
|
|
loopbackTestInprogress(2),
|
|
loopbackTestCompleted(3) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the status of the remote loopback
|
|
test.
|
|
'notInitiated' indicates that the loopback has not been
|
|
initiated yet.
|
|
'loopbackbTestInprogress' indicates that the loopback test is in
|
|
progress.
|
|
'loopbackbTestCompleted' indicates that the loopback test has been
|
|
completed."
|
|
|
|
::= { fsFmLoopbackEntry 7 }
|
|
|
|
fsFmLBTestStartTimestamp OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(40))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Start timestamp of the current loopback test."
|
|
::= { fsFmLoopbackEntry 8 }
|
|
|
|
fsFmLBTestEndTimestamp OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(40))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"End timestamp of the current loopback test."
|
|
::= { fsFmLoopbackEntry 9 }
|
|
|
|
fsFmLBTestTxCount OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Statistics of number of Test packets transmitted during
|
|
current loopback test."
|
|
::= { fsFmLoopbackEntry 10 }
|
|
|
|
fsFmLBTestRxCount OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Statistics of number of Test packets received during
|
|
current loopback test."
|
|
::= { fsFmLoopbackEntry 11 }
|
|
|
|
fsFmLBTestMatchCount OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Statistics of number of Test packets that matched with the
|
|
test pattern sent during current loopback test."
|
|
::= { fsFmLoopbackEntry 12 }
|
|
|
|
-- Loopback test previous session statistics table
|
|
fsFmLBStatsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsFmLBStatsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains statistics of the last remote loopback
|
|
test."
|
|
::= { fsFmLoopback 2 }
|
|
|
|
fsFmLBStatsEntry OBJECT-TYPE
|
|
SYNTAX FsFmLBStatsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains remote loopback test results of the
|
|
last session. This table is updated every time a new loopback
|
|
test session is started. The current fsFmLBTestTxCount,
|
|
fsFmLBTestRxCount and fsFmLBTestMatchCount are copied to
|
|
this table before starting the new test."
|
|
INDEX { ifIndex }
|
|
::= { fsFmLBStatsTable 1 }
|
|
|
|
FsFmLBStatsEntry ::= SEQUENCE {
|
|
fsFmLBStatsStartTimestamp DisplayString,
|
|
fsFmLBStatsEndTimestamp DisplayString,
|
|
fsFmLBStatsTxCount Unsigned32,
|
|
fsFmLBStatsRxCount Unsigned32,
|
|
fsFmLBStatsMatchCount Unsigned32
|
|
}
|
|
|
|
fsFmLBStatsStartTimestamp OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(40))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Start timestamp of the current loopback test."
|
|
::= { fsFmLBStatsEntry 1 }
|
|
|
|
fsFmLBStatsEndTimestamp OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(40))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"End timestamp of the current loopback test."
|
|
::= { fsFmLBStatsEntry 2 }
|
|
|
|
|
|
fsFmLBStatsTxCount OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Statistics of number of Test packets transmitted during
|
|
last loopback test."
|
|
::= { fsFmLBStatsEntry 3 }
|
|
|
|
fsFmLBStatsRxCount OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Statistics of number of Test packets received during
|
|
last loopback test."
|
|
::= { fsFmLBStatsEntry 4 }
|
|
|
|
fsFmLBStatsMatchCount OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Statistics of number of Test packets that matched with the
|
|
test pattern sent."
|
|
::= { fsFmLBStatsEntry 5 }
|
|
|
|
|
|
-- ------------------------------------------------------------------
|
|
-- The FM Variable Retrieval Group
|
|
-- ------------------------------------------------------------------
|
|
|
|
-- This table contains objects configure the variable request and to
|
|
-- clear variable response table
|
|
|
|
fsFmVarRetrievalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsFmVarRetrievalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains objects to configure MIB variable
|
|
requests to be sent and clear variable response table"
|
|
::= { fsFmVarRetrieval 1 }
|
|
|
|
fsFmVarRetrievalEntry OBJECT-TYPE
|
|
SYNTAX FsFmVarRetrievalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the list of Branch and Leaves
|
|
to be sent out for a Variable Request"
|
|
INDEX { ifIndex}
|
|
::= { fsFmVarRetrievalTable 1 }
|
|
|
|
FsFmVarRetrievalEntry ::= SEQUENCE {
|
|
fsFmVarRetrievalMaxVar Unsigned32,
|
|
fsFmVarRetrievalRequest DisplayString,
|
|
fsFmVarRetrievalClearResponse INTEGER
|
|
}
|
|
|
|
fsFmVarRetrievalMaxVar OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute specifies the maximum number of Variable
|
|
descriptors that can be sent on the interface"
|
|
|
|
DEFVAL { 10 }
|
|
::= { fsFmVarRetrievalEntry 1 }
|
|
|
|
fsFmVarRetrievalRequest OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..255))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute specifies the Variable descriptor string
|
|
that will be sent in the Variable Request OAMPDU. Setting
|
|
this attribute also sends the variable request OAMPDU.
|
|
|
|
The format of the string should be 'BL:BL:...:00', where
|
|
'B' - stands for CMIP Branch (one-byte)
|
|
'L' - stands for CMIP Leaf (two bytes) of the CMIP variable defined
|
|
under Clause 30 of IEEE specification."
|
|
::= { fsFmVarRetrievalEntry 2 }
|
|
|
|
fsFmVarRetrievalClearResponse OBJECT-TYPE
|
|
SYNTAX INTEGER { notCleared(1),
|
|
clearResponseLog(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute clears the variable response log on
|
|
the specified interface. Writing 'clearResponseLog' to
|
|
this variable cause the 'fsFmVarResponseTable' to be cleared.
|
|
Writing 'notCleared' to this attribute has no effect.
|
|
|
|
This attribute always returns 'notCleared' on a read."
|
|
|
|
::= { fsFmVarRetrievalEntry 3 }
|
|
|
|
-- This table contains objects to store the variable responses
|
|
-- received
|
|
|
|
fsFmVarResponseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsFmVarResponseEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the log of the Variable responses
|
|
received"
|
|
::= { fsFmVarRetrieval 3 }
|
|
|
|
fsFmVarResponseEntry OBJECT-TYPE
|
|
SYNTAX FsFmVarResponseEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the list of Variable responses
|
|
received on each interface. If the response is too long,
|
|
it is split and stored in multiple parts"
|
|
INDEX { ifIndex, fsFmVarResponseId }
|
|
::= { fsFmVarResponseTable 1 }
|
|
|
|
FsFmVarResponseEntry ::= SEQUENCE {
|
|
fsFmVarResponseId Unsigned32,
|
|
fsFmVarResponseRx1 DisplayString,
|
|
fsFmVarResponseRx2 DisplayString,
|
|
fsFmVarResponseRx3 DisplayString,
|
|
fsFmVarResponseRx4 DisplayString,
|
|
fsFmVarResponseRx5 DisplayString,
|
|
fsFmVarResponseRx6 DisplayString
|
|
}
|
|
|
|
fsFmVarResponseId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An arbitrary integer for identifiying more than one
|
|
Response received on an interface"
|
|
::= { fsFmVarResponseEntry 1 }
|
|
|
|
fsFmVarResponseRx1 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the data received on the Variable response. If the
|
|
received response is more than 255 bytes, it will split into
|
|
multiple parts and stored"
|
|
::= { fsFmVarResponseEntry 2 }
|
|
|
|
fsFmVarResponseRx2 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the data received on the Variable response. If the
|
|
received response is more than 255 bytes, it will split into
|
|
multiple parts and stored"
|
|
::= { fsFmVarResponseEntry 3 }
|
|
|
|
fsFmVarResponseRx3 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the data received on the Variable response. If the
|
|
received response is more than 255 bytes, it will split into
|
|
multiple parts and stored"
|
|
::= { fsFmVarResponseEntry 4 }
|
|
|
|
fsFmVarResponseRx4 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the data received on the Variable response. If the
|
|
received response is more than 255 bytes, it will split into
|
|
multiple parts and stored"
|
|
::= { fsFmVarResponseEntry 5 }
|
|
|
|
fsFmVarResponseRx5 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the data received on the Variable response. If the
|
|
received response is more than 255 bytes, it will split into
|
|
multiple parts and stored"
|
|
::= { fsFmVarResponseEntry 6 }
|
|
|
|
fsFmVarResponseRx6 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the data received on the Variable response. If the
|
|
received response is more than 255 bytes, it will split into
|
|
multiple parts and stored"
|
|
::= { fsFmVarResponseEntry 7 }
|
|
END
|