193 lines
6.1 KiB
Plaintext
193 lines
6.1 KiB
Plaintext
-- Copyright (C) 2008-2012 Aricent Group . All Rights Reserved
|
|
|
|
-- $Id: fsradius.mib,v 1.5 2015/04/28 12:25:01 siva Exp $
|
|
|
|
-- ****************************************************************************
|
|
-- * Document Version Info *
|
|
-- ****************************************************************************
|
|
-- *Version | Date | Author | Changes *
|
|
-- * ------------------------------------------------------------------------ *
|
|
-- * 1.1 | 31st MAY 2000 | Private |Removed duplicate objects*
|
|
-- * | | |available in Std Table *
|
|
-- * | | | *
|
|
-- * | | | *
|
|
-- ****************************************************************************
|
|
|
|
-- RADIUS-CLIENT-MIB DEFINITIONS ::= BEGIN
|
|
|
|
|
|
ARICENT-RADIUS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE,
|
|
Integer32, enterprises,
|
|
IpAddress FROM SNMPv2-SMI
|
|
DisplayString, RowStatus FROM SNMPv2-TC
|
|
InterfaceIndex FROM IF-MIB;
|
|
|
|
|
|
futureRADIUSMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201209050000Z"
|
|
ORGANIZATION "ARICENT COMMUNICATIONS SOFTWARE"
|
|
CONTACT-INFO "support@aricent.com"
|
|
DESCRIPTION " The RADIUS ext. MIB is placed under futuresoftware MIB branch."
|
|
REVISION "201209050000Z"
|
|
DESCRIPTION " The RADIUS ext. MIB is placed under futuresoftware MIB branch."
|
|
::= { enterprises futuresoftware (2076) 25 }
|
|
|
|
|
|
|
|
radiusExtClient OBJECT IDENTIFIER ::= { futureRADIUSMIB 1 }
|
|
|
|
|
|
radiusExtDebugMask OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to enable Trace Statements in
|
|
Radius Module.
|
|
|
|
A FOUR BYTE integer is used for enabling the level of tracing.
|
|
Each BIT in the four byte integer, represents a particular
|
|
level of Trace.
|
|
|
|
The maping between the bit positions & the level of trace is
|
|
as follows:
|
|
0 - Error Traces
|
|
1 - Event Traces
|
|
2 - Packet Traces
|
|
3 - Response Traces
|
|
4 - Timer Traces
|
|
|
|
The remaining bits are unused. Combination of levels are
|
|
also allowed.
|
|
|
|
For example if the bits 0 and 1 are set, then the Trace
|
|
statements related to Error and Event
|
|
will be printed.
|
|
|
|
The user has to enter the corresponding INTEGER VALUE for the
|
|
bits set. For example if bits 0 and 1 are set then user has to
|
|
give the value 3."
|
|
::= { radiusExtClient 1 }
|
|
|
|
radiusMaxNoOfUserEntries OBJECT-TYPE
|
|
SYNTAX Integer32 (1 ..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Max of No of User entries stored.For value of this
|
|
object will be stored for the MemPool Initialization."
|
|
::= { radiusExtClient 2 }
|
|
|
|
radiusExtServerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RadiusExtServerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The (conceptual) table listing the RADIUS servers with
|
|
which the client shares a secret."
|
|
::= { radiusExtClient 3 }
|
|
|
|
radiusExtServerEntry OBJECT-TYPE
|
|
SYNTAX RadiusExtServerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry (conceptual row) representing a RADIUS server
|
|
with which the client shares a secret."
|
|
INDEX {radiusExtServerIndex}
|
|
::= { radiusExtServerTable 1 }
|
|
|
|
RadiusExtServerEntry ::= SEQUENCE {
|
|
radiusExtServerIndex InterfaceIndex,
|
|
radiusExtServerAddress IpAddress,
|
|
radiusExtServerType INTEGER,
|
|
radiusExtServerSharedSecret DisplayString,
|
|
radiusExtServerEnabled INTEGER,
|
|
radiusExtServerResponseTime INTEGER,
|
|
radiusExtServerMaximumRetransmission INTEGER,
|
|
radiusExtServerEntryStatus RowStatus
|
|
}
|
|
|
|
|
|
radiusExtServerIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The RADIUS server with whom the client interacts."
|
|
::= { radiusExtServerEntry 1 }
|
|
|
|
radiusExtServerAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP address of the RADIUS server
|
|
referred to in this table entry."
|
|
::= { radiusExtServerEntry 2 }
|
|
|
|
radiusExtServerType OBJECT-TYPE
|
|
SYNTAX INTEGER { auth (1),
|
|
acct (2),
|
|
both (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The RADIUS server type (Authentication or Accounting or Both).
|
|
For creating a server entry Server Type should be set"
|
|
::= { radiusExtServerEntry 3 }
|
|
|
|
radiusExtServerSharedSecret OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The secret string which is shared between Server and Client"
|
|
::= { radiusExtServerEntry 4 }
|
|
|
|
radiusExtServerEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER { enabled (1),
|
|
disabled (2),
|
|
destroy (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Flag to tell whether the server is active or Inactive"
|
|
DEFVAL { enabled }
|
|
::= { radiusExtServerEntry 5 }
|
|
|
|
radiusExtServerResponseTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1 ..120)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum time within which the server has to respond for a
|
|
request from the client"
|
|
::= { radiusExtServerEntry 6 }
|
|
|
|
radiusExtServerMaximumRetransmission OBJECT-TYPE
|
|
SYNTAX INTEGER (1 ..254)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The allowed maximum no. of trials to be tried by a client to get
|
|
response from the server for a request"
|
|
::= { radiusExtServerEntry 7 }
|
|
|
|
radiusExtServerEntryStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the entry can be used as specified in the SNMP V2
|
|
standard. "
|
|
::= { radiusExtServerEntry 8 }
|
|
|
|
END
|
|
|