-- Copyright (C) 2010-2012 Aricent Group . All Rights Reserved
|
|
|
|
-- $Id: fsmptp.mib,v 1.5 2012/09/07 09:52:05 siva Exp $
|
|
ARICENT-MPLS-TP-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE,
|
|
Unsigned32, enterprises
|
|
FROM SNMPv2-SMI -- [RFC2578]
|
|
TruthValue, RowStatus, DisplayString
|
|
FROM SNMPv2-TC; -- [RFC2579]
|
|
|
|
fsMplsTpMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201209050000Z"
|
|
ORGANIZATION "ARICENT COMMUNICATIONS SOFTWARE"
|
|
CONTACT-INFO "support@aricent.com"
|
|
DESCRIPTION "The Proprietary MIB for MPLS TP module"
|
|
REVISION "201209050000Z"
|
|
DESCRIPTION "The Proprietary MIB for MPLS TP module"
|
|
::= { enterprises futuresoftware (2076) futureMpls (13) 8}
|
|
|
|
-- Notifications
|
|
fsMplsTpNotifications OBJECT IDENTIFIER ::= { fsMplsTpMIB 0 }
|
|
-- MPLS Transport Profile objects
|
|
fsMplsTpObjects OBJECT IDENTIFIER ::= { fsMplsTpMIB 1 }
|
|
-- conformance
|
|
fsMplsTpConformance OBJECT IDENTIFIER ::= { fsMplsTpMIB 2 }
|
|
-- MPLS Transport Profile scalar objects
|
|
fsMplsTpScalarObjects OBJECT IDENTIFIER ::= { fsMplsTpObjects 1 }
|
|
|
|
-- Start of MPLS Transport Profile Global configuration table
|
|
|
|
fsMplsTpGlobalConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsMplsTpGlobalConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table allows configurations that global for MPLS-TP
|
|
per virtual context. Configurations include global or operator
|
|
identifier, node identifier, ICC value and etc.,"
|
|
::= { fsMplsTpObjects 2 }
|
|
|
|
fsMplsTpGlobalConfigEntry OBJECT-TYPE
|
|
SYNTAX FsMplsTpGlobalConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An Entry in this table represents per virtual context MPLS-TP
|
|
Global parameters. An entry in this table is created when a virtual
|
|
context is created."
|
|
INDEX { fsMplsTpContextId }
|
|
::= { fsMplsTpGlobalConfigTable 1 }
|
|
|
|
FsMplsTpGlobalConfigEntry ::= SEQUENCE {
|
|
fsMplsTpContextId Unsigned32,
|
|
fsMplsTpOamModuleStatus INTEGER,
|
|
fsMplsTpGlobalId Unsigned32,
|
|
fsMplsTpIcc DisplayString,
|
|
fsMplsTpNodeIdentifier Unsigned32,
|
|
fsMplsTpErrorCode INTEGER,
|
|
fsMplsTpTraceLevel Unsigned32,
|
|
fsMplsTpNotificationEnable TruthValue
|
|
}
|
|
|
|
fsMplsTpContextId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A 32-bit unique identifier to identify the virtual context.
|
|
|
|
Currently, the implementation supports only the default virtual
|
|
context. Value of this object should always be set to zero."
|
|
::= { fsMplsTpGlobalConfigEntry 1 }
|
|
|
|
fsMplsTpOamModuleStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1),
|
|
disabled (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows the administrator to enable or disable MPLS-TP
|
|
OAM module."
|
|
DEFVAL { enabled }
|
|
::= { fsMplsTpGlobalConfigEntry 2 }
|
|
|
|
fsMplsTpGlobalId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows the administrator to assign a unique operator
|
|
identifier also called MPLS-TP Global Identifier.
|
|
|
|
The Global Identifier can contain the 2-octet or 4-octet value
|
|
of the operator's Autonomous System Number (ASN).
|
|
|
|
Note: This object is not automatically derived from the ASN number.
|
|
The user has to configure this object explicitly. The value of this
|
|
object will be used as the default value for a service if the
|
|
operator fails to configure the Global ID for that service.A Global-Id
|
|
with 0 is the default value and is not a valid configuration for a
|
|
operationally active node."
|
|
REFERENCE
|
|
"MPLS-TP Identifiers draft version 02, Section 3.1"
|
|
DEFVAL { 0 }
|
|
::= { fsMplsTpGlobalConfigEntry 3 }
|
|
|
|
fsMplsTpIcc OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..6))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows the operator or service provider to assign a
|
|
unique MPLS-TP ITU-T Carrier Code (ICC) to a network.
|
|
|
|
The ICC is a string of one to six characters, each character
|
|
being either alphabetic (i.e. A-Z) or numeric (i.e. 0-9)
|
|
characters. Alphabetic characters in the ICC should be
|
|
represented with upper case letters."
|
|
REFERENCE
|
|
"MPLS-TP Identifiers draft version 02, Section 3.2"
|
|
::= { fsMplsTpGlobalConfigEntry 4 }
|
|
|
|
fsMplsTpNodeIdentifier OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows the operator or service provider to assign a
|
|
unique MPLS-TP Node Identifier.
|
|
|
|
The Node Identifier is assigned within the scope of the Global
|
|
Identifier or Operator Identifier.
|
|
|
|
The value 0 (or 0.0.0.0 in dotted decimal notation) is reserved
|
|
and MUST NOT be used.
|
|
|
|
When IPv4 addresses are in use, the value of this object can be
|
|
derived from the LSR's /32 IPv4 loopback address.
|
|
|
|
Note that, when IP reachability is not needed, the 32-bit Node
|
|
Identifier is not required to have any association with the IPv4
|
|
address space.
|
|
|
|
Note: The value of this object has to be explicitly configured
|
|
by the user in both cases.A Node Id with 0 is the default
|
|
value and is not a valid configuration for a operationally
|
|
active node."
|
|
REFERENCE
|
|
"MPLS-TP Identifiers draft version 02, Section 4"
|
|
DEFVAL { 0 }
|
|
::= { fsMplsTpGlobalConfigEntry 5 }
|
|
|
|
fsMplsTpErrorCode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
elpsAssociationExists (1),
|
|
megAssociationExists (2),
|
|
pseudowireAssociationExists (3),
|
|
proactiveSessionExists (4),
|
|
elpsProactiveSessionExists (5),
|
|
activeMeExists(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the information about the latest error
|
|
that occurred when administrator is unable to set an object
|
|
in MPLS OAM Management database due to the presence of a
|
|
dependent information.
|
|
elpsAssociationExists (1) - Destroy of the lower layer application is not allowed
|
|
when the Enhanced Linear Protection Module
|
|
association exits.
|
|
megAssociationExists (2) - Destroy of the lower layer application is not allowed
|
|
when the MEG association exits.
|
|
pseudowireAssociationExists (3) - Destroy of the lower layer application is not allowed
|
|
when the pseudowire association exits.
|
|
proactiveSessionAssociationExists (4) - Destroy of the lower layer application is not allowed
|
|
when the proactive session association exits.
|
|
proactiveSessionAssociationExists (5) - Destroy of the lower layer application is not allowed
|
|
when there is proactive session and ELPS association exits.
|
|
activeMeExists(6) - Modifying MEG entry is not allowed, if there is an associated active ME
|
|
entry exists."
|
|
::= { fsMplsTpGlobalConfigEntry 6 }
|
|
|
|
fsMplsTpTraceLevel OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to enable Trace Statements in
|
|
MPLS Module.
|
|
|
|
A FOUR BYTE integer is used for enabling the level of tracing.
|
|
Each BIT in the four byte integer, represents a particular
|
|
level of Trace.
|
|
|
|
The mapping between the bit positions & the level of trace is
|
|
as follows:
|
|
0x100000 - Function Entry or Exit Traces
|
|
0x010000 - Management Traces
|
|
0x001000 - Main Traces
|
|
0x000100 - Util Traces
|
|
0x000010 - Traces related to All Resources except Buffers
|
|
0x000001 - All Failure Traces
|
|
|
|
The remaining bits are unused. Combination of levels are
|
|
also allowed.
|
|
|
|
For example if the bits 0 and 1 are set, then the Trace
|
|
statements related to Init-Shutdown and management
|
|
will be printed.
|
|
|
|
The user has to enter the corresponding INTEGER VALUE for the
|
|
bits set. For example if bits 0 and 1 are set then user has to
|
|
set the value 3."
|
|
DEFVAL { 0 }
|
|
::= { fsMplsTpGlobalConfigEntry 7 }
|
|
|
|
|
|
fsMplsTpNotificationEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When this objects is true, then it enables the
|
|
generation of MEG DOWN, ME DOWN, MEG UP and ME UP
|
|
traps, otherwise these traps are not generated."
|
|
DEFVAL { false }
|
|
::= { fsMplsTpGlobalConfigEntry 8 }
|
|
|
|
-- End of MPLS Transport Profile Global configuration table
|
|
|
|
-- Start of MPLS Transport Profile Node Map table
|
|
fsMplsTpNodeMapTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsMplsTpNodeMapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table allows the administrator to map a node or LSR with an
|
|
operator or service provider. "
|
|
::= { fsMplsTpObjects 3 }
|
|
|
|
fsMplsTpNodeMapEntry OBJECT-TYPE
|
|
SYNTAX FsMplsTpNodeMapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in this table represents a mapping identification for the
|
|
operator or service provider with node or LSR.
|
|
|
|
As per draft-ietf-mpls-tp-identifiers-02, this mapping is
|
|
represented as Global_ID::Node_ID.
|
|
|
|
Note: Each entry in this table should have a unique global ID and
|
|
Node ID combination."
|
|
INDEX { fsMplsTpContextId,
|
|
fsMplsTpNodeMapLocalNum }
|
|
::= { fsMplsTpNodeMapTable 1 }
|
|
|
|
FsMplsTpNodeMapEntry ::= SEQUENCE {
|
|
fsMplsTpNodeMapLocalNum Unsigned32,
|
|
fsMplsTpNodeMapGlobalId Unsigned32,
|
|
fsMplsTpNodeMapNodeId Unsigned32,
|
|
fsMplsTpNodeMapRowStatus RowStatus
|
|
}
|
|
|
|
fsMplsTpNodeMapLocalNum OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows the administrator to assign a unique identifier to
|
|
map operator or global identifier and node identifier."
|
|
::= { fsMplsTpNodeMapEntry 1 }
|
|
|
|
fsMplsTpNodeMapGlobalId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object Indicates the Global or Operator Identifier.
|
|
This object identifies an operator."
|
|
::= { fsMplsTpNodeMapEntry 2 }
|
|
|
|
fsMplsTpNodeMapNodeId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the node identifier within the operator."
|
|
::= { fsMplsTpNodeMapEntry 3 }
|
|
|
|
fsMplsTpNodeMapRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows the administrator to create, modify, and/or delete
|
|
a row in this table."
|
|
::= { fsMplsTpNodeMapEntry 4 }
|
|
|
|
-- End MPLS Transport Profile Node Map table
|
|
|
|
END
|