Observium_CE/mibs/aricent/ARICENT-MITUNNEL-MIB

414 lines
16 KiB
Plaintext

-- Copyright (C) 2009-2012 Aricent Group . All Rights Reserved
-- /*****************************************************************
-- * *
-- * $RCSfile: fsmptunl.mib,v $ *
-- * *
-- * $Date: 2012/09/07 09:52:05 $ *
-- * *
-- * $Revision: 1.1 - IPv4/IPv6 Tunnel MIB based on draft *
-- <draft-thaler-inet-tunnel-mib-00.txt> *
-- * *
-- ****************************************************************/
ARICENT-MITUNNEL-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Integer32, Unsigned32, enterprises FROM SNMPv2-SMI
RowStatus, TEXTUAL-CONVENTION, DisplayString, TruthValue FROM SNMPv2-TC
InetAddressType, InetAddress FROM INET-ADDRESS-MIB
InterfaceIndexOrZero FROM IF-MIB
fsMIStdIpContextId FROM ARICENT-MISTD-IPVX-MIB;
fsMITunlMIB MODULE-IDENTITY
LAST-UPDATED "201209050000Z"
ORGANIZATION "ARICENT COMMUNICATIONS SOFTWARE"
CONTACT-INFO "support@aricent.com"
DESCRIPTION
"The MIB module for management of IP (IPv4 and IPv6) Tunnels,
independent of the specific encapsulation scheme in use."
REVISION "201209050000Z"
DESCRIPTION
"The MIB module for management of IP (IPv4 and IPv6) Tunnels,
independent of the specific encapsulation scheme in use."
::= { enterprises aricent-communication-holding-ltd(29601) iss(2) 39}
FsMITunlType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The encapsulation method used by a tunnel. The value
direct indicates that a packet is encapsulated
directly within a normal IP header, with no
intermediate header, and unicast to the remote tunnel
endpoint (e.g., an RFC 2003 IP-in-IP tunnel, or an RFC
1933 IPv6-in-IPv4 tunnel). The value minimal indicates
that a Minimal Forwarding Header (RFC 2004) is
inserted between the outer header and the payload
packet. The value UDP indicates that the payload
packet is encapsulated within a normal UDP packet
(e.g., RFC 1234).
The values sixToFour, sixOverFour, and isatap
indicates that an IPv6 packet is encapsulated directly
within an IPv4 header, with no intermediate header,
and unicast to the destination determined by the 6to4,
6over4, or ISATAP protocol.
The remaining protocol-specific values indicate that a
header of the protocol of that name is inserted
between the outer header and the payload header.
This type is abstracted from the IANAtunnelType."
SYNTAX INTEGER {
other(1), -- none of the following
direct(2), -- no intermediate header
gre(3), -- GRE encapsulation
minimal(4), -- Minimal encapsulation
l2tp(5), -- L2TP encapsulation
pptp(6), -- PPTP encapsulation
l2f(7), -- L2F encapsulation
udp(8), -- UDP encapsulation
atmp(9), -- ATMP encapsulation
msdp(10), -- MSDP encapsulation
sixToFour(11), -- 6to4 encapsulation
sixOverFour(12), -- 6over4 encapsulation
isatap(13), -- ISATAP encapsulation
teredo(14), -- Teredo encapsulation
compat(15), -- IPv6 Auto-Compatible encapsulation
ipv6ip(16) -- IPv6 over IPV4 Configured encapsulation
}
FsIPv6FlowLabelOrAny ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION "The flow identifier or Flow Label in an IPv6
packet header that may be used to discriminate
traffic flows. The value of -1 is used to
indicate a wildcard, i.e. any value."
SYNTAX Integer32 (-1 | 0..1048575)
fsMITunlMIBObjects OBJECT IDENTIFIER ::= { fsMITunlMIB 1 }
fsMITunl OBJECT IDENTIFIER ::= { fsMITunlMIBObjects 1 }
-- the IP Tunnel MIB-Group
--
-- a collection of objects providing information about
-- IP Tunnels
fsMITunlIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF FsMITunlIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The (conceptual) table containing virtual router specific
information on configured tunnels."
::= { fsMITunl 1 }
fsMITunlIfEntry OBJECT-TYPE
SYNTAX FsMITunlIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The (conceptual) table containing information on
configured tunnels. This table can be used to map a
set of tunnel endpoints to the associated ifIndex
value. It can also be used for row creation."
INDEX {
fsMIStdIpContextId,
fsMITunlIfAddressType,
fsMITunlIfLocalInetAddress,
fsMITunlIfRemoteInetAddress,
fsMITunlIfEncapsMethod,
fsMITunlIfConfigID }
::= { fsMITunlIfTable 1 }
FsMITunlIfEntry ::= SEQUENCE {
fsMITunlIfAddressType InetAddressType,
fsMITunlIfLocalInetAddress InetAddress,
fsMITunlIfRemoteInetAddress InetAddress,
fsMITunlIfEncapsMethod FsMITunlType,
fsMITunlIfConfigID Integer32,
fsMITunlIfHopLimit Integer32,
fsMITunlIfSecurity INTEGER,
fsMITunlIfTOS Integer32,
fsMITunlIfFlowLabel FsIPv6FlowLabelOrAny,
fsMITunlIfMTU Integer32,
fsMITunlIfDirFlag INTEGER,
fsMITunlIfDirection INTEGER,
fsMITunlIfEncaplmt Unsigned32,
fsMITunlIfEncapOption INTEGER,
fsMITunlIfIndex InterfaceIndexOrZero,
fsMITunlIfAlias DisplayString,
fsMITunlIfCksumFlag TruthValue,
fsMITunlIfPmtuFlag TruthValue,
fsMITunlIfStatus RowStatus
}
fsMITunlIfAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The type of address in the corresponding
fsMITunlIfLocalInetAddress and fsMITunlIfRemoteInetAddress
objects."
::= { fsMITunlIfEntry 1 }
fsMITunlIfLocalInetAddress OBJECT-TYPE
SYNTAX InetAddress (SIZE(16))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The address of the local endpoint of the tunnel
(i.e., the source address used in the outer IP
header). If the address is unknown, the value is
0.0.0.0 for IPv4 or :: for IPv6."
::= { fsMITunlIfEntry 2 }
fsMITunlIfRemoteInetAddress OBJECT-TYPE
SYNTAX InetAddress (SIZE(16))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The address of the remote endpoint of the tunnel
(i.e., the destination address used in the outer IP
header). If the address is unknown or the tunnel is
not a point-to-point link (e.g., if it is a 6to4
tunnel), the value is 0.0.0.0 for tunnels over IPv4 or
:: for tunnels over IPv6."
::= { fsMITunlIfEntry 3 }
fsMITunlIfEncapsMethod OBJECT-TYPE
SYNTAX FsMITunlType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The encapsulation method used by the tunnel."
::= { fsMITunlIfEntry 4 }
fsMITunlIfConfigID OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An identifier used to distinguish between multiple
tunnels of the same encapsulation method, with the
same endpoints. If the encapsulation protocol only
allows one tunnel per set of endpoint addresses (such
as for GRE or IP-in-IP), the value of this object is
1. For encapsulation methods (such as L2F) which
allow multiple parallel tunnels, the manager is
responsible for choosing any ID which does not
conflict with an existing row, such as choosing a
random number."
::= { fsMITunlIfEntry 5 }
fsMITunlIfHopLimit OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv4 TTL or IPv6 Hop Limit to use in the outer IP
header. A value of 0 indicates that the value is
copied from the payload's header."
::= { fsMITunlIfEntry 6 }
fsMITunlIfSecurity OBJECT-TYPE
SYNTAX INTEGER {
none(1), -- no security
ipsec(2), -- IPSEC security
other(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The method used by the tunnel to secure the outer IP
header. The value ipsec indicates that IPsec is used
between the tunnel endpoints for authentication or
encryption or both. More specific security-related
information may be available in a MIB for the security
protocol in use."
::= { fsMITunlIfEntry 7 }
fsMITunlIfTOS OBJECT-TYPE
SYNTAX Integer32 (-2..63)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The method used to set the high 6 bits of the IPv4
TOS or IPv6 Traffic Class in the outer IP header. A
value of -1 indicates that the bits are copied from
the payload's header. A value of -2 indicates that a
traffic conditioner is invoked and more information
may be available in a traffic conditioner MIB. A
value between 0 and 63 inclusive indicates that the
bit field is set to the indicated value."
::= { fsMITunlIfEntry 8 }
fsMITunlIfFlowLabel OBJECT-TYPE
SYNTAX FsIPv6FlowLabelOrAny
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The method used to set the IPv6 Flow Label value.
This object need not be present in rows where
fsMITunlIfAddressType indicates the tunnel is over IPv6.
A value of -1 indicates that a traffic conditioner is
invoked and more information may be available in a
traffic conditioner MIB. Any other value indicates
that the Flow Label field is set to the indicated
value."
::= { fsMITunlIfEntry 9 }
fsMITunlIfMTU OBJECT-TYPE
SYNTAX Integer32 (0 | 1280..1500)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Configured MTU of the specific tunnel entry. If set as 0,
the outgoing Link MTU will be used."
::= { fsMITunlIfEntry 10 }
fsMITunlIfDirFlag OBJECT-TYPE
SYNTAX INTEGER
{
unidirectional (1),
bidirectional (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Flag defining whether the configured tunnel is
unidirectional or bi-directional."
DEFVAL { bidirectional }
::= { fsMITunlIfEntry 11 }
fsMITunlIfDirection OBJECT-TYPE
SYNTAX INTEGER
{
incoming (1),
outgoing (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Flag defining whether the uni-directional tunnel
configured is incoming or out going."
DEFVAL { outgoing }
::= { fsMITunlIfEntry 12 }
fsMITunlIfEncaplmt OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The limit on how many further levels of nesting a tunnel
packet is permitted to undergo - not counting the
encapsulation in which the option itself is contained.
Default value recommended is 4. If this option is not to
be configured set this object to '0xff' else set to
the value required."
DEFVAL { 4 }
::= { fsMITunlIfEntry 13 }
fsMITunlIfEncapOption OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Flag indicating if Encapsulation option needs to be added
or not in a tunnelled packet."
DEFVAL { disable }
::= { fsMITunlIfEntry 14 }
fsMITunlIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the value of fsMITunlIfStatus for this row
is active, then this object contains the value of
ifIndex corresponding to the tunnel interface. A
value of 0 is not legal in the active state, and means
that the interface index has not yet been assigned."
::= { fsMITunlIfEntry 15 }
fsMITunlIfAlias OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If the value of fsMITunlIfStatus for this row
is active, then this object contains the value of
ifAlias corresponding to the tunnel interface.
The value of fsMITunlIfIndex is assigned based on
the corresponding fsMITunlIfAlias entry in ifMainTable."
::= { fsMITunlIfEntry 16 }
fsMITunlIfCksumFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Flag indicating if checksum needs to be set in GRE header
for GRE encapsulation type"
DEFVAL { false }
::= { fsMITunlIfEntry 17 }
fsMITunlIfPmtuFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Flag indicating if path-mtu-discovery needs to be enabled on the
tunnel interface. When enabled, path-mtu-discovery is done to set
the MTU of the tunnel interface. When disabled, the outgoing link
MTU will be used"
DEFVAL { false }
::= { fsMITunlIfEntry 18 }
fsMITunlIfStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this row, by which new entries may be
created, or old entries deleted from this table.
To create a row in this table for an encapsulation
method which does not support multiple parallel
tunnels with the same endpoints, the management
station should simply use a fsMITunlInetConfigID of 1,
and set fsMITunlInetConfigStatus to createAndGo. For
encapsulation methods such as L2F which allow multiple
parallel tunnels, the management station may select a
pseudo-random number to use as the fsMITunlInetConfigID
and set fsMITunlInetConfigStatus to createAndGo. In the
event that this ID is already in use and an
inconsistentValue is returned in response to the set
operation, the management station should simply select
a new pseudo-random number and retry the operation.
Creating a row in this table will cause an interface
index to be assigned by the agent in an
implementation-dependent manner, and corresponding
rows will be instantiated in the ifTable and the
fsMITunlIfTable. The status of this row will become
active as soon as the agent assigns the interface
index, regardless of whether the interface is
operationally up.
Deleting a row in this table will likewise delete the
corresponding row in the ifTable and in the
fsMITunlIfTable."
::= { fsMITunlIfEntry 19 }