-- AT-ALMMON-MIB, Allied Telesis enterprise MIB:
|
|
-- Alarm Monitoring MIB objects.
|
|
--
|
|
-- Copyright (c) 2014 by Allied Telesis, Inc.
|
|
-- All rights reserved.
|
|
--
|
|
-- ============================================================================
|
|
|
|
AT-ALMMON-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
DisplayStringUnsized
|
|
FROM AT-SMI-MIB
|
|
sysinfo
|
|
FROM AT-SYSINFO-MIB
|
|
Unsigned32, OBJECT-TYPE, MODULE-IDENTITY
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION, TruthValue
|
|
FROM SNMPv2-TC;
|
|
|
|
|
|
atAlmMon MODULE-IDENTITY
|
|
LAST-UPDATED "201902120000Z"
|
|
ORGANIZATION
|
|
"Allied Telesis, Inc"
|
|
CONTACT-INFO
|
|
"http://www.alliedtelesis.com"
|
|
DESCRIPTION
|
|
"The AT Alarm Monitoring MIB for managing and
|
|
reporting device alarms."
|
|
REVISION "201902120000Z"
|
|
DESCRIPTION
|
|
"Extended to support per stack member configuration."
|
|
REVISION "201809200000Z"
|
|
DESCRIPTION
|
|
"Added UFO alarm type.
|
|
Removed AtAlmMonAlarmType zero enumeration."
|
|
REVISION "201702080000Z"
|
|
DESCRIPTION
|
|
"Added g8032 as an alarm type."
|
|
REVISION "201405120015Z"
|
|
DESCRIPTION
|
|
"Changes from maintainer review"
|
|
REVISION "201312131146Z"
|
|
DESCRIPTION
|
|
"Initial Revision"
|
|
|
|
::= { sysinfo 26 }
|
|
|
|
|
|
|
|
--
|
|
-- Textual conventions
|
|
--
|
|
|
|
AtAlmMonAlarmType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the type of a monitored alarm."
|
|
SYNTAX INTEGER
|
|
{
|
|
externalPSU(1),
|
|
epsr(2),
|
|
contactInput(3),
|
|
portLinkDown(4),
|
|
loopDetect(5),
|
|
mainPse(6),
|
|
portPoeFailure(7),
|
|
temperature(8),
|
|
g8032(9),
|
|
ufo(10)
|
|
}
|
|
|
|
|
|
AtAlmMonActionUseOutput ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether or not the output device (relay or fault LED) is used for this alarm."
|
|
SYNTAX INTEGER
|
|
{
|
|
unused(1),
|
|
used(2)
|
|
}
|
|
|
|
|
|
AtAlmMonAbnormalState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the abnormal (i.e. alarm active) state for a contact input alarm monitor."
|
|
SYNTAX INTEGER
|
|
{
|
|
open(1),
|
|
closed(2)
|
|
}
|
|
|
|
AtAlmMonActionState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the current state of this alarm monitor."
|
|
SYNTAX INTEGER
|
|
{
|
|
inactive(1),
|
|
active(2)
|
|
}
|
|
|
|
AtAlmMonContactPosition ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the position state for a contact input."
|
|
SYNTAX INTEGER
|
|
{
|
|
open(1),
|
|
closed(2)
|
|
}
|
|
--
|
|
-- Node definitions
|
|
--
|
|
-- ---------------------------------------------------------- --
|
|
-- The Alarm Monitoring actions table
|
|
-- ---------------------------------------------------------- --
|
|
|
|
atAlmMonActionTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtAlmMonActionEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of information describing alarm monitoring inputs
|
|
and consequent actions (i.e. fault LED & relay outputs)."
|
|
::= { atAlmMon 1 }
|
|
|
|
|
|
atAlmMonActionEntry OBJECT-TYPE
|
|
SYNTAX AtAlmMonActionEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The description and configuration of what to do for a specific monitored alarm."
|
|
INDEX { atAlmMonActionStackMemberId, atAlmMonActionIndex }
|
|
::= { atAlmMonActionTable 1 }
|
|
|
|
AtAlmMonActionEntry ::=
|
|
SEQUENCE {
|
|
atAlmMonActionStackMemberId
|
|
Unsigned32,
|
|
atAlmMonActionIndex
|
|
Unsigned32,
|
|
atAlmMonAlarmType
|
|
AtAlmMonAlarmType,
|
|
atAlmMonAlarmTypeSelection
|
|
Unsigned32,
|
|
atAlmMonActionDescription
|
|
DisplayStringUnsized,
|
|
atAlmMonActionUseRelay1
|
|
AtAlmMonActionUseOutput,
|
|
atAlmMonActionUseRelay2
|
|
AtAlmMonActionUseOutput,
|
|
atAlmMonActionUseRelay3
|
|
AtAlmMonActionUseOutput,
|
|
atAlmMonActionUseFaultLed
|
|
AtAlmMonActionUseOutput,
|
|
atAlmMonAbnormalState
|
|
AtAlmMonAbnormalState,
|
|
atAlmMonActionState
|
|
AtAlmMonActionState
|
|
}
|
|
|
|
atAlmMonActionStackMemberId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the stack member of this alarm action."
|
|
::= { atAlmMonActionEntry 1 }
|
|
|
|
|
|
atAlmMonActionIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The numeric identifier of this alarm action."
|
|
::= { atAlmMonActionEntry 2 }
|
|
|
|
|
|
atAlmMonAlarmType OBJECT-TYPE
|
|
SYNTAX AtAlmMonAlarmType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of alarm that this action monitors."
|
|
::= { atAlmMonActionEntry 3 }
|
|
|
|
|
|
atAlmMonAlarmTypeSelection OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The 1-based index of the alarm of the particular type (as catagorised by atAlmMonAlarmType)."
|
|
::= { atAlmMonActionEntry 4 }
|
|
|
|
|
|
atAlmMonActionDescription OBJECT-TYPE
|
|
SYNTAX DisplayStringUnsized (SIZE (0..30))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The description of this alarm monitoring entry."
|
|
::= { atAlmMonActionEntry 5 }
|
|
|
|
|
|
atAlmMonActionUseRelay1 OBJECT-TYPE
|
|
SYNTAX AtAlmMonActionUseOutput
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates/controls whether or not this alarm monitor drives the first relay output."
|
|
::= { atAlmMonActionEntry 6 }
|
|
|
|
|
|
atAlmMonActionUseRelay2 OBJECT-TYPE
|
|
SYNTAX AtAlmMonActionUseOutput
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates/controls whether or not this alarm monitor drives the second relay output."
|
|
::= { atAlmMonActionEntry 7 }
|
|
|
|
atAlmMonActionUseRelay3 OBJECT-TYPE
|
|
SYNTAX AtAlmMonActionUseOutput
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates/controls whether or not this alarm monitor drives the third relay output."
|
|
::= { atAlmMonActionEntry 8 }
|
|
|
|
|
|
atAlmMonActionUseFaultLed OBJECT-TYPE
|
|
SYNTAX AtAlmMonActionUseOutput
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates/controls whether or not this alarm monitor drives the fault LED."
|
|
::= { atAlmMonActionEntry 9 }
|
|
|
|
atAlmMonAbnormalState OBJECT-TYPE
|
|
SYNTAX AtAlmMonAbnormalState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates/sets the abnormal (i.e. alarm active) state for a contact input.
|
|
Only used for contactInput alarm monitors, ignored for all other types."
|
|
::= { atAlmMonActionEntry 10 }
|
|
|
|
|
|
atAlmMonActionState OBJECT-TYPE
|
|
SYNTAX AtAlmMonActionState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the current state of this alarm monitor."
|
|
::= { atAlmMonActionEntry 11 }
|
|
|
|
--
|
|
-- Tables to support per stack configuration
|
|
--
|
|
-- ---------------------------------------------------------- --
|
|
-- The Alarm Monitoring available alarms table
|
|
-- ---------------------------------------------------------- --
|
|
atAlmMonPerStackConfiguration OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether to support per stack member configuration.
|
|
|
|
A true value means that atAlmMonAvailableTable, atAlmMonOutputRelayTable,
|
|
atAlmMonOutputLedTable and atAlmMonIutputContactTable are supported.
|
|
|
|
A notTrue value means that atAlmMonActionTable is supported.
|
|
|
|
This object should be set to a value that reflects the way that alarm
|
|
monitors are actually configured or to be configured."
|
|
|
|
::= { atAlmMon 2 }
|
|
|
|
atAlmMonAvailableTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtAlmMonAvailableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of information listing available alarms on the device."
|
|
::= { atAlmMon 3 }
|
|
|
|
atAlmMonAvailableEntry OBJECT-TYPE
|
|
SYNTAX AtAlmMonAvailableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The description and configuration of each available alarm."
|
|
INDEX { atAlmMonAvailableAlarmId }
|
|
::= { atAlmMonAvailableTable 1 }
|
|
|
|
AtAlmMonAvailableEntry ::=
|
|
SEQUENCE {
|
|
atAlmMonAvailableAlarmId
|
|
Unsigned32,
|
|
atAlmMonAvailableType
|
|
AtAlmMonAlarmType,
|
|
atAlmMonAvailableTypeIndex
|
|
Unsigned32,
|
|
atAlmMonAvailableStkId
|
|
Unsigned32,
|
|
atAlmMonAvailableIfName
|
|
DisplayStringUnsized,
|
|
atAlmMonAvailableState
|
|
AtAlmMonActionState
|
|
}
|
|
|
|
atAlmMonAvailableAlarmId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique numeric identifier for this alarm."
|
|
::= { atAlmMonAvailableEntry 1 }
|
|
|
|
atAlmMonAvailableType OBJECT-TYPE
|
|
SYNTAX AtAlmMonAlarmType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of this alarm, such as externalPSU(1), epsr(2), etc."
|
|
::= { atAlmMonAvailableEntry 2 }
|
|
|
|
atAlmMonAvailableTypeIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the particular alarm type (catagorised by atAlmMonAlarmType).
|
|
|
|
For some alarms there are multiple sources on the device (i.e. power supplies).
|
|
In these cases this object indicates which source the alarm is for (i.e.
|
|
power supply 1, or power supply 2).
|
|
|
|
This object is used for externalPSU(1) and contactInput(3) alarm only."
|
|
::= { atAlmMonAvailableEntry 3 }
|
|
|
|
atAlmMonAvailableStkId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The id of stack member this alarm triggers on.
|
|
|
|
This object is used for externalPSU(1), contactInput(3), portLinkDown(4),
|
|
portPoeFailure(7) and temperature(8) alarm only."
|
|
::= { atAlmMonAvailableEntry 4 }
|
|
|
|
atAlmMonAvailableIfName OBJECT-TYPE
|
|
SYNTAX DisplayStringUnsized (SIZE (0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the specific interface that this alarm triggers on, such as 'port1.0.1.
|
|
|
|
This object is used for portLinkDown(4) and portPoeFailure(7) alarm only."
|
|
::= { atAlmMonAvailableEntry 5 }
|
|
|
|
atAlmMonAvailableState OBJECT-TYPE
|
|
SYNTAX AtAlmMonActionState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the current state of this alarm."
|
|
::= { atAlmMonAvailableEntry 6 }
|
|
|
|
-- ---------------------------------------------------------- --
|
|
-- The Alarm Monitoring output relay table
|
|
-- ---------------------------------------------------------- --
|
|
|
|
atAlmMonOutputRelayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtAlmMonOutputRelayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table lists all associations existing on the device between output
|
|
relays and alarms.
|
|
|
|
Theoretically, an output relay on the device can be triggered by multiple
|
|
alarms and an alarm can trigger multiple output relays."
|
|
::= { atAlmMon 4 }
|
|
|
|
atAlmMonOutputRelayEntry OBJECT-TYPE
|
|
SYNTAX AtAlmMonOutputRelayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry reprents an association between one ouput relay and one alarm.
|
|
|
|
To configure an alarm to use an output relay, a user needs to create a new
|
|
entry. This can be done through writing a value of used(2) to object
|
|
atAlmMonOutputRelayUsage that is specified by atAlmMonOutputRelayStkId,
|
|
atAlmMonOutputRelayNumber, and atAlmMonOutputRelayAlarmId.
|
|
|
|
To reconfigure an alarm not to use an output relay, a user needs to delete
|
|
the entry. This can be done by writing a value of unused(1) to object
|
|
atAlmMonOutputRelayUsage."
|
|
INDEX { atAlmMonOutputRelayStkId, atAlmMonOutputRelayNumber, atAlmMonOutputRelayAlarmId }
|
|
::= { atAlmMonOutputRelayTable 1 }
|
|
|
|
AtAlmMonOutputRelayEntry ::=
|
|
SEQUENCE {
|
|
atAlmMonOutputRelayStkId
|
|
Unsigned32,
|
|
atAlmMonOutputRelayNumber
|
|
Unsigned32,
|
|
atAlmMonOutputRelayAlarmId
|
|
Unsigned32,
|
|
atAlmMonOutputRelayUsage
|
|
AtAlmMonActionUseOutput
|
|
}
|
|
|
|
atAlmMonOutputRelayStkId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The id of stack member that the relay(s) reside on."
|
|
::= { atAlmMonOutputRelayEntry 1 }
|
|
|
|
atAlmMonOutputRelayNumber OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number (i.e. the 1 based index) of the relay."
|
|
::= { atAlmMonOutputRelayEntry 2 }
|
|
|
|
atAlmMonOutputRelayAlarmId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The id of the alarm that may use this relay output."
|
|
::= { atAlmMonOutputRelayEntry 3 }
|
|
|
|
atAlmMonOutputRelayUsage OBJECT-TYPE
|
|
SYNTAX AtAlmMonActionUseOutput
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether or not the relay output is used.
|
|
|
|
Since there are entries only for existing associations between the output
|
|
relays and the alarms, the object value should be always used(2).
|
|
|
|
If a user sets a value of unused(1) to this object, then the whole entry
|
|
will be deleted.
|
|
|
|
If a user sets a value of used(2) to this object with new index, then
|
|
a new entry should be created if stack member id, relay number and
|
|
alarm id are specified properly in the index."
|
|
::= { atAlmMonOutputRelayEntry 4 }
|
|
|
|
-- ---------------------------------------------------------- --
|
|
-- The Alarm Monitoring output led table
|
|
-- ---------------------------------------------------------- --
|
|
|
|
atAlmMonOutputLedTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtAlmMonOutputLedEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table lists all associations existing on the device between output
|
|
LED(s) and alarms.
|
|
|
|
Theoretically, an output LED on the device can be triggered by multiple
|
|
alarms and an alarm can trigger multiple LED(s)."
|
|
::= { atAlmMon 5 }
|
|
|
|
atAlmMonOutputLedEntry OBJECT-TYPE
|
|
SYNTAX AtAlmMonOutputLedEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry reprents an association between one LED and one alarm.
|
|
|
|
To configure an alarm to use an output LED, a user needs to create a new
|
|
entry. This can be done through writing a value of used(2) to object
|
|
atAlmMonOutputLedUsage that is specified by atAlmMonOutputLedStkId and
|
|
atAlmMonOutputRelayAlarmId.
|
|
|
|
To reconfigure an alarm not to use an output LED, a user needs to delete
|
|
the entry. This can be done by writing a value of unused(1) to object
|
|
atAlmMonOutputLedUsage."
|
|
INDEX { atAlmMonOutputRelayStkId, atAlmMonOutputRelayAlarmId }
|
|
::= { atAlmMonOutputLedTable 1 }
|
|
|
|
AtAlmMonOutputLedEntry ::=
|
|
SEQUENCE {
|
|
atAlmMonOutputLedStkId
|
|
Unsigned32,
|
|
atAlmMonOutputLedAlarmId
|
|
Unsigned32,
|
|
atAlmMonOutputLedUsage
|
|
AtAlmMonActionUseOutput
|
|
}
|
|
|
|
atAlmMonOutputLedStkId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The id of stack member that the output LED resides on."
|
|
::= { atAlmMonOutputLedEntry 1 }
|
|
|
|
atAlmMonOutputLedAlarmId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The id of the alarm that may use this output LED."
|
|
::= { atAlmMonOutputLedEntry 2 }
|
|
|
|
atAlmMonOutputLedUsage OBJECT-TYPE
|
|
SYNTAX AtAlmMonActionUseOutput
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether or not an LED is used.
|
|
|
|
Since there are entries only for existing associations between the output
|
|
LED(s) and the alarms, the object value should be always used(2).
|
|
|
|
If a user sets a value of unused(1) to this object, then the whole entry
|
|
will be deleted.
|
|
|
|
If a user sets a value of used(2) to this object with new index, then
|
|
a new entry should be created if stack member id and alarm id are
|
|
specified properly in the index."
|
|
::= { atAlmMonOutputLedEntry 3 }
|
|
|
|
-- ---------------------------------------------------------- --
|
|
-- The Alarm Monitoring input contact table
|
|
-- ---------------------------------------------------------- --
|
|
|
|
atAlmMonInputContactTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtAlmMonInputContactEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table lists all input contacts on the device and their positions."
|
|
::= { atAlmMon 6 }
|
|
|
|
atAlmMonInputContactEntry OBJECT-TYPE
|
|
SYNTAX AtAlmMonInputContactEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The information of each input contact configuration."
|
|
INDEX { atAlmMonInputContactStkId, atAlmMonInputContactNumber }
|
|
::= { atAlmMonInputContactTable 1 }
|
|
|
|
AtAlmMonInputContactEntry ::=
|
|
SEQUENCE {
|
|
atAlmMonInputContactStkId
|
|
Unsigned32,
|
|
atAlmMonInputContactNumber
|
|
Unsigned32,
|
|
atAlmMonInputContactPosition
|
|
AtAlmMonContactPosition
|
|
}
|
|
|
|
atAlmMonInputContactStkId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The id of stack member that the input contact reside on."
|
|
::= { atAlmMonInputContactEntry 1 }
|
|
|
|
atAlmMonInputContactNumber OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number (i.e. the 1 based index) of the input contact."
|
|
::= { atAlmMonInputContactEntry 2 }
|
|
|
|
atAlmMonInputContactPosition OBJECT-TYPE
|
|
SYNTAX AtAlmMonContactPosition
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the position of the input contact. It is either
|
|
open or closed.
|
|
A user can reconfigure the position of an input contact by setting
|
|
a different value to this object."
|
|
::= { atAlmMonInputContactEntry 3 }
|
|
|
|