ADTRAN-GENSLOT-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- TITLE: Generic chassis slot MIB (SMIv2)
|
|
-- PRODUCT: All chassis type products
|
|
-- VERSION: 1.0
|
|
-- DATE: 99/12/29
|
|
-- AUTHOR: Phil Bergstresser
|
|
-- SNMP: SNMPv2
|
|
-- MIB ARC: adtran.adShared.adGenericShelves.adGenSlot
|
|
|
|
-- HISTORY:
|
|
-- 03/10/00 pnb add hyphens to module name
|
|
-- 03/23/00 pnb add adProductID textual convention
|
|
-- 03/24/00 pnb add alarm & visual objects
|
|
-- 03/27/00 pnb remove dynamic slot creation and unify names
|
|
-- 04/10/00 pnb remove chassis qualifiers
|
|
-- 04/18/00 pnb make indexes visible ala SNMPv1, and correct sequence
|
|
-- 04/27/00 pnb change name of alarm state
|
|
-- 05/03/00 pnb migrate number of ports/slot from genport MIB to here
|
|
-- 05/24/00 pnb add slot selector virtual object for legacy line cards
|
|
-- 09/15/00 pnb add comment clarification for alarm status format
|
|
-- 01/04/01 pnb add objects for firmware upgrade
|
|
-- 02/02/01 pnb change checksum to Provisioning Version for reliability
|
|
-- add comments about row accessibility in empty slots
|
|
-- 02/07/01 pnb add sysUpTime equivalentfor each card, which imports from rfc1155
|
|
-- 03/01/01 pnb deprecate slotSelector
|
|
-- 05/18/01 pnb add format conventions for faceplate LEDs and switches,
|
|
-- and make other clarifications in descriptions.
|
|
-- Changed adGenSlotSelector status from deprecated to obsolete.
|
|
-- 09/04/01 wss Added filename length requirement to adGenSlotTFileName in
|
|
-- description field.
|
|
-- 08/01/02 ked Changed description field of adGenSlotProduct to remove the '0' requirement
|
|
-- for empty slots.
|
|
-- 06/13/03 dcc Converted to SMIv2; commented out obsolete adGenSlotSelector
|
|
-- 09/19/08 pnb Remove index range from adGenSlotInfoIndex
|
|
-- 09/25/08 pnb Augment description of adGenSlotFaceplate for consistency, & remove adGenSlotumber limit
|
|
-- 09/22/09 twc Added traps for slot service state OOS-MA active/clear and an OID for enabling/disabling this alarm.
|
|
-- 10/28/09 srao Interchanged the values of enable/disable of the OID adGenSlotServiceStateOOSMAAlarmEnable
|
|
-- 07/21/10 tas Added adGenSlotPrimaryBuildDate
|
|
-- "DO NOT MAKE HISTORY COMMENTS HERE!!!! Revision history now in REVISION/DESCRIPTION clauses below"
|
|
|
|
IMPORTS
|
|
OBJECT-TYPE, MODULE-IDENTITY,
|
|
Integer32, TimeTicks,Counter32,
|
|
NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
DisplayString,
|
|
PhysAddress,
|
|
TruthValue
|
|
FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
sysName
|
|
FROM SNMPv2-MIB
|
|
AdPresence,
|
|
AdProductIdentifier
|
|
FROM ADTRAN-TC
|
|
adTrapInformSeqNum
|
|
FROM ADTRAN-GENTRAPINFORM-MIB
|
|
ifIndex, ifDescr
|
|
FROM IF-MIB
|
|
adGenericShelves
|
|
FROM ADTRAN-GENCHASSIS-MIB;
|
|
|
|
-- Slot Group
|
|
adGenSlot MODULE-IDENTITY
|
|
LAST-UPDATED "201608120000Z"
|
|
ORGANIZATION "ADTRAN, Inc."
|
|
CONTACT-INFO
|
|
" Technical Support Dept.
|
|
Postal: ADTRAN, Inc.
|
|
901 Explorer Blvd.
|
|
Huntsville, AL 35806
|
|
|
|
Tel: +1 800 726-8663
|
|
Fax: +1 256 963 6217
|
|
E-mail: support@adtran.com"
|
|
DESCRIPTION
|
|
"The MIB module that describes the generic objects
|
|
used to mananage individual cards in a shelf/bank
|
|
developed by ADTRAN, Inc."
|
|
REVISION "201703290000Z"
|
|
DESCRIPTION "add adGenSlotUpTimeSeconds to allow the Web and AOE retrieve the uptime in seconds"
|
|
REVISION "201608120000Z"
|
|
DESCRIPTION "Changed severity varbind for adGenSlotCpuRateLimitAlarmClear and adGenSlotCpuRateLimitAlarmActive to an
|
|
existing OID already defined for provisioning the alarm severity. This resolves the issue of circular dependency if
|
|
adTAeSCUTrapAlarmLevel is used for the same purpose."
|
|
REVISION "201603140000Z"
|
|
DESCRIPTION "Added adGenSlotCpuRateLimitAlarmClear and adGenSlotCpuRateLimitAlarmActive for CPU rate limit alarm.
|
|
Added adGenSlotProvCpuRateLimitAlarmSlotSeverity and adGenSlotProvCpuRateLimitAlarmSlotEnableCPU for setting severity
|
|
and enabling the CPU Rate Limit alarm."
|
|
REVISION "201305310000Z"
|
|
DESCRIPTION "Obsolete the Slot OOS-MA alarm and the associated enable/disable provisioning."
|
|
REVISION "201212060000Z"
|
|
DESCRIPTION "add adGenSlotWarmStartCause/IsValid to identify reason for a warm start"
|
|
REVISION "201209210000Z"
|
|
DESCRIPTION "add adGenSlotResetCause to identify reason for module restart"
|
|
REVISION "201110130000Z"
|
|
DESCRIPTION "add FPGA BIST failure alarm"
|
|
|
|
::= { adGenericShelves 2 }
|
|
|
|
adGenSlotConformance OBJECT IDENTIFIER ::= { adGenSlot 99 }
|
|
|
|
adGenSlotNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of slots (regardless of
|
|
their current state) present on this system.
|
|
This may be inferred by the product ID also."
|
|
::= { adGenSlot 1 }
|
|
|
|
-- Slot table
|
|
-- Rows exist for all physical slots as defined by adGenSlotNumber.
|
|
-- The first three objects (columns) in each row are always visible,
|
|
-- but the remaining columnar objects are non-existant for empty slots,
|
|
-- and will return no such name on gets or will be skipped on getnexts.
|
|
|
|
adGenSlotInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenSlotInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of slots available for boards."
|
|
::= { adGenSlot 3 }
|
|
|
|
adGenSlotInfoEntry OBJECT-TYPE
|
|
SYNTAX AdGenSlotInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { adGenSlotInfoIndex }
|
|
::= { adGenSlotInfoTable 1 }
|
|
|
|
AdGenSlotInfoEntry ::=
|
|
SEQUENCE {
|
|
adGenSlotInfoIndex
|
|
Integer32,
|
|
adGenSlotInfoState
|
|
AdPresence,
|
|
adGenSlotProduct
|
|
AdProductIdentifier,
|
|
adGenSlotTrapEnable
|
|
INTEGER,
|
|
adGenSlotAlarmStatus
|
|
OCTET STRING,
|
|
adGenSlotFaceplate
|
|
OCTET STRING,
|
|
adGenSlotStatServiceState
|
|
INTEGER,
|
|
adGenSlotPortNumber
|
|
Integer32,
|
|
adGenSlotProvVersion
|
|
Integer32,
|
|
-- adGenSlotSelector
|
|
-- OCTET STRING,
|
|
adGenSlotTFileName
|
|
DisplayString,
|
|
adGenSlotUpdateSoftware
|
|
INTEGER,
|
|
adGenSlotUpdateStatus
|
|
DisplayString,
|
|
adGenSlotUpTime
|
|
TimeTicks,
|
|
adGenSlotServiceStateOOSMAAlarmEnable
|
|
INTEGER,
|
|
adGenSlotPrimaryBuildDate
|
|
DisplayString,
|
|
adGenSlotResetCause
|
|
DisplayString,
|
|
adGenSlotWarmStartCauseIsValid
|
|
TruthValue,
|
|
adGenSlotWarmStartCause
|
|
DisplayString,
|
|
adGenSlotUpTimeSeconds
|
|
Counter32
|
|
}
|
|
|
|
adGenSlotInfoIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for each slot. Its value may exceed
|
|
the value of adGenSlotNumber if pseudo slot numbers
|
|
are used for some bank commons or multiplexers.
|
|
This object is visible for all rows."
|
|
::= { adGenSlotInfoEntry 1 }
|
|
|
|
adGenSlotInfoState OBJECT-TYPE
|
|
SYNTAX AdPresence
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The state of the card slot. Initially it is empty.
|
|
When a card is inserted, it becomes occupied, and the
|
|
Slot Type is determined by the card Product Code.
|
|
When a card is removed, it changes to virtual,
|
|
and retains the SlotType characteristics until a
|
|
different kind of card is inserted, or a different
|
|
preconfiguration is established.
|
|
This object is visible for all rows."
|
|
::= { adGenSlotInfoEntry 3 }
|
|
|
|
adGenSlotProduct OBJECT-TYPE
|
|
SYNTAX AdProductIdentifier
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ADTRAN Product code. Agent will report
|
|
real product code when installed or pre-provisioned.
|
|
This object is visible for all rows. It is defined in the ADTRAN-TC."
|
|
::= { adGenSlotInfoEntry 4 }
|
|
|
|
adGenSlotTrapEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enableTraps(1),
|
|
disableTraps(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables/Disables traps initiated from this slot. Note that
|
|
cards out of service will not generate traps."
|
|
::= { adGenSlotInfoEntry 5 }
|
|
|
|
adGenSlotAlarmStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit encoded string representing the alarm state of
|
|
the slot. The LSB should be 1 for No Alarm, else 0 and
|
|
the higher order bits will indicate which alarms are
|
|
present. The specific alarm conditions may be found in
|
|
more specific generic MIBs or in the device MIB.
|
|
This may report the same status as xxxLineStatus in
|
|
internet standard line MIBs."
|
|
::= { adGenSlotInfoEntry 6 }
|
|
|
|
adGenSlotFaceplate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit encoded string representing the status of faceplate
|
|
indicators, LEDs, buttons & switches for GUI visualization.
|
|
The first byte will be the number of LED/switches encoded.
|
|
The following bytes will contain 2 bit sequences in network order
|
|
for each LED or switch, from the top to the bottom of the faceplate.
|
|
The final byte may be padded with zeros.
|
|
The meaning of each pair of bits for LEDs is:
|
|
00 - off
|
|
01 - color A on only
|
|
10 - color B on only (not used for mono-colors)
|
|
11 - both A & B on (not used for mono-colors)
|
|
The meaning of each pair of bits for switches or buttons is:
|
|
00 - not pressed if button
|
|
01 - up or right switch position, or pressed if button
|
|
10 - down or left switch position
|
|
11 - middle switch position
|
|
The definition of colors and/or on/off switch values will be
|
|
defined in the product specific MIB.
|
|
This may be cached at the chassis level.
|
|
|
|
Conventions proposed 1/18/2006 for common reuse and consistency.
|
|
1. Use values of 0 for Black, 1 for Green, 2 for Red and 3 for Yellow,
|
|
which maps to the OID definition of Green for color A, Red for color B,
|
|
and Yellow for Both on.
|
|
|
|
2. The MIB is not specific about multi-column LED displays,
|
|
so follow the common convention of Left column first, followed by Right column,
|
|
always top to bottom as the MIB requires.
|
|
|
|
3. Blink is occasionally desired, but impossible to implement effectively for
|
|
rate or duty cycle on raster graphic GUIs. Alternate the status value on successive
|
|
SNMP gets if the bit has changed state multiple times. This will simulate the
|
|
changing of state even though the frequency cannot be represented accurately."
|
|
::= { adGenSlotInfoEntry 7 }
|
|
|
|
adGenSlotStatServiceState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
is(1), -- In Service
|
|
oosUas(2), -- Out of Service, Unassigned
|
|
oosMA(3), -- Out of Service, Maintenance mode
|
|
fault(5), -- autonomous fault
|
|
isStbyHot(8), -- In Service, standby hot (prot only)
|
|
isActLock(9), -- In Service, active locked (prot only)
|
|
isStbyLock(10) -- In Service, standby locked (prot only)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module service state. Port service states are commanded via
|
|
ifAdminStatus and reported via ifOperStatus in the IF-MIB.
|
|
Those states of up, down, & testing correspond to the first
|
|
three states defined here for the card."
|
|
::= { adGenSlotInfoEntry 8 }
|
|
|
|
adGenSlotPortNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of physical ports (regardless of
|
|
their current state) present in this slot."
|
|
::= { adGenSlotInfoEntry 9 }
|
|
|
|
adGenSlotProvVersion OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter starting at 0 which is incremented by the agent
|
|
after each provisioning change so that an EMS can detect that
|
|
a change has been made locally that needs further investigation
|
|
to achieve synchronization."
|
|
::= { adGenSlotInfoEntry 10 }
|
|
|
|
-- adGenSlotSelector OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING (SIZE (0|1))
|
|
-- MAX-ACCESS read-write
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "Include this object in a PDU to imply a slot for compatibility
|
|
-- support for legacy products that used community name suffixes."
|
|
-- ::= { adGenSlotInfoEntry 11 }
|
|
|
|
adGenSlotTFileName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Filename for tftp software update. A minimum of length of 25
|
|
characters must be supported. Server is defined in genchass.mib"
|
|
::= { adGenSlotInfoEntry 13 }
|
|
|
|
adGenSlotUpdateSoftware OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
initiate(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A set command will initiate tftp download.
|
|
Get has no meaning and will always return 1."
|
|
::= { adGenSlotInfoEntry 15 }
|
|
|
|
adGenSlotUpdateStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A progress indication during download which can be polled."
|
|
::= { adGenSlotInfoEntry 16 }
|
|
|
|
adGenSlotUpTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time (in hundredths of a second) since the
|
|
card was powered up. This is comparable to the
|
|
mib-2.system.sysUpTime timer object for the IP
|
|
addressable agent, but is unique for each card."
|
|
::= { adGenSlotInfoEntry 17 }
|
|
|
|
|
|
adGenSlotServiceStateOOSMAAlarmEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Enables/disables the card service state OOS-MA alarm."
|
|
::= { adGenSlotInfoEntry 18 }
|
|
|
|
adGenSlotPrimaryBuildDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gives the most recent build date of the slot."
|
|
::= { adGenSlotInfoEntry 19 }
|
|
|
|
adGenSlotResetCause OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gives the reason why this slot restarted."
|
|
::= { adGenSlotInfoEntry 20 }
|
|
|
|
adGenSlotWarmStartCauseIsValid OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the DisplayString returned by adGenSlotWarmStartCause is valid."
|
|
::= { adGenSlotInfoEntry 21 }
|
|
|
|
adGenSlotWarmStartCause OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If a warm start condition occurred, returns the reason for the warm start.
|
|
This object is only valid if adGenSlotWarmStartCauseIsValid is true."
|
|
::= { adGenSlotInfoEntry 22 }
|
|
|
|
adGenSlotUpTimeSeconds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time (in seconds) since the card was powered up."
|
|
::= { adGenSlotInfoEntry 23 }
|
|
|
|
|
|
|
|
--
|
|
-- Product Information group
|
|
--
|
|
-- This group contains information common for most all Adtran
|
|
-- products. It is a slot addressable copy of the multi-scoped
|
|
-- ADTRAN-MIB. It augments the slot info table.
|
|
--
|
|
|
|
adGenSlotProdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenSlotProdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of slots available for boards."
|
|
::= { adGenSlot 4 }
|
|
|
|
adGenSlotProdEntry OBJECT-TYPE
|
|
SYNTAX AdGenSlotProdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { adGenSlotInfoIndex }
|
|
::= { adGenSlotProdTable 1 }
|
|
|
|
AdGenSlotProdEntry ::=
|
|
SEQUENCE {
|
|
adGenSlotProdName
|
|
DisplayString,
|
|
adGenSlotProdPartNumber
|
|
DisplayString,
|
|
adGenSlotProdCLEIcode
|
|
DisplayString,
|
|
adGenSlotProdSerialNumber
|
|
DisplayString,
|
|
adGenSlotProdRevision
|
|
DisplayString,
|
|
adGenSlotProdSwVersion
|
|
DisplayString,
|
|
adGenSlotProdPhysAddress
|
|
PhysAddress,
|
|
adGenSlotProdProductID
|
|
OBJECT IDENTIFIER,
|
|
adGenSlotProdTransType
|
|
DisplayString
|
|
}
|
|
|
|
adGenSlotProdName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Adtran Product Name"
|
|
::= { adGenSlotProdEntry 1 }
|
|
|
|
adGenSlotProdPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Adtran Product Part Number"
|
|
::= { adGenSlotProdEntry 2 }
|
|
|
|
adGenSlotProdCLEIcode OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Adtran Product CLEI Code"
|
|
::= { adGenSlotProdEntry 3 }
|
|
|
|
adGenSlotProdSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Adtran Product Serial Number"
|
|
::= { adGenSlotProdEntry 4 }
|
|
|
|
adGenSlotProdRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Adtran Product Revision Number"
|
|
::= { adGenSlotProdEntry 5 }
|
|
|
|
adGenSlotProdSwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Adtran Product Software Version Number"
|
|
::= { adGenSlotProdEntry 6 }
|
|
|
|
adGenSlotProdPhysAddress OBJECT-TYPE
|
|
SYNTAX PhysAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This octet string variable is the same as the ifPhysAddress
|
|
in IF-MIB. THe SCU will report MAC address, else 0 for other cards."
|
|
::= { adGenSlotProdEntry 7 }
|
|
|
|
adGenSlotProdProductID OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Adtran Product ID equivalent to sysObjectID"
|
|
::= { adGenSlotProdEntry 8 }
|
|
|
|
adGenSlotProdTransType OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The data transmission circuit/facility/payload level of the
|
|
device (see Appendix A of GR-833-CORE). Common examples are:
|
|
T0, T1, T2, T3, STS1, and OC3. For the SCU and other common
|
|
equipment cards, the code should be EQPT."
|
|
::= { adGenSlotProdEntry 9 }
|
|
|
|
--
|
|
-- Alarms
|
|
--
|
|
adGenSlotAlarmsPrefix OBJECT IDENTIFIER ::= { adGenSlot 5 }
|
|
adGenSlotAlarms OBJECT IDENTIFIER ::= { adGenSlotAlarmsPrefix 0 }
|
|
|
|
adGenSlotServiceStateOOSMAClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates Slot Service State is no longer OOS-MA"
|
|
--#TYPE "Warning - Slot Service OOS-MA Alarm Clear"
|
|
--#SUMMARY "Shelf: %s, Slot: %d"
|
|
--#SEVERITY WARNING
|
|
--#ARGUMENTS {1,2}
|
|
::= {adGenSlotAlarms 1}
|
|
|
|
adGenSlotServiceStateOOSMAActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates Slot Service State is currently OOS-MA. This alarm is the single exception to the rule of 'no alarms are active when in OOS-MA' "
|
|
--#TYPE "Warning - Slot Service State OOS-MA Alarm Active"
|
|
--#SUMMARY "Shelf: %s, Slot: %d"
|
|
--#SEVERITY WARNING
|
|
--#ARGUMENTS {1,2}
|
|
::= {adGenSlotAlarms 2}
|
|
|
|
adGenSlotFpgaBistFailureClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Indicates FPGA built-in self-test failure cleared"
|
|
--#TYPE "Critical - Slot FPGA built-in self-test failure cleared"
|
|
--#SEVERITY CRITICAL
|
|
::= {adGenSlotAlarms 3}
|
|
|
|
adGenSlotFpgaBistFailureActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Indicates FPGA built-in self-test failed"
|
|
--#TYPE "Critical - FPGA built-in self-test failed"
|
|
--#SEVERITY CRITICAL
|
|
::= {adGenSlotAlarms 4}
|
|
|
|
adGenSlotCpuRateLimitAlarmClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
ifDescr,
|
|
ifIndex,
|
|
adGenSlotProvCpuRateLimitAlarmSlotSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Exception rate parameters are within bounds and alarm has cleared."
|
|
--#TYPE "Status - SA CPU Rate Limit Alarm Clear"
|
|
--#SUMMARY "Shelf: %s, Details: %s"
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY MAJOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenSlotAlarms 5}
|
|
|
|
adGenSlotCpuRateLimitAlarmActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
ifDescr,
|
|
ifIndex,
|
|
adGenSlotProvCpuRateLimitAlarmSlotSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Exception rate parameters are out of bounds and alarm has activated"
|
|
--#TYPE "Status - SA CPU Rate Limit Alarm Active"
|
|
--#SUMMARY "Shelf: %s, Details: %s"
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY MAJOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenSlotAlarms 6}
|
|
|
|
--
|
|
-- CPU Rate Limit Alarm Provisioning Group
|
|
--
|
|
adGenSlotProvCpuRateLimitAlarmSlotTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenSlotProvCpuRateLimitAlarmSlotEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Table sets severity and suppression for CPU Rate Limit Alarm."
|
|
::= { adGenSlot 9 }
|
|
|
|
adGenSlotProvCpuRateLimitAlarmSlotEntry OBJECT-TYPE
|
|
SYNTAX AdGenSlotProvCpuRateLimitAlarmSlotEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { adGenSlotInfoIndex }
|
|
::= { adGenSlotProvCpuRateLimitAlarmSlotTable 1 }
|
|
|
|
AdGenSlotProvCpuRateLimitAlarmSlotEntry ::=
|
|
SEQUENCE {
|
|
adGenSlotProvCpuRateLimitAlarmSlotSeverity INTEGER,
|
|
adGenSlotProvCpuRateLimitAlarmSlotEnable TruthValue
|
|
}
|
|
|
|
adGenSlotProvCpuRateLimitAlarmSlotSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
minor(4),
|
|
major(5),
|
|
critical(6)
|
|
}
|
|
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the Service Affecting Severity for CPU rate limit alarm."
|
|
DEFVAL { major }
|
|
::= { adGenSlotProvCpuRateLimitAlarmSlotEntry 1 }
|
|
|
|
adGenSlotProvCpuRateLimitAlarmSlotEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"True - Enables the alarm, False - disables the alarm"
|
|
|
|
DEFVAL {true}
|
|
::= { adGenSlotProvCpuRateLimitAlarmSlotEntry 2 }
|
|
|
|
-- compliance statements
|
|
-- These two subidentifiers are for local use in this MIB only
|
|
adGenSlotCompliances OBJECT IDENTIFIER ::= { adGenSlotConformance 1 }
|
|
adGenSlotMIBGroups OBJECT IDENTIFIER ::= { adGenSlotConformance 2 }
|
|
|
|
adGenSlotCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for SNMPv2 entities which implement the
|
|
adtran generic slot MIB."
|
|
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
adGenSlotBaseGroup
|
|
}
|
|
|
|
GROUP adGenSlotOptionalGroup
|
|
DESCRIPTION
|
|
"Group of objects which are supported by some products."
|
|
|
|
::= { adGenSlotCompliances 1 }
|
|
|
|
adGenSlotBaseGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
adGenSlotNumber,
|
|
adGenSlotInfoIndex,
|
|
adGenSlotInfoState,
|
|
adGenSlotProduct,
|
|
adGenSlotTrapEnable,
|
|
adGenSlotAlarmStatus,
|
|
adGenSlotFaceplate,
|
|
adGenSlotStatServiceState,
|
|
adGenSlotPortNumber,
|
|
adGenSlotProvVersion,
|
|
adGenSlotTFileName,
|
|
adGenSlotUpdateSoftware,
|
|
adGenSlotUpdateStatus,
|
|
adGenSlotUpTime,
|
|
adGenSlotProdName,
|
|
adGenSlotProdPartNumber,
|
|
adGenSlotProdCLEIcode,
|
|
adGenSlotProdSerialNumber,
|
|
adGenSlotProdRevision,
|
|
adGenSlotProdSwVersion,
|
|
adGenSlotProdPhysAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ADTRAN Generic Slot Base Group."
|
|
::= { adGenSlotMIBGroups 1 }
|
|
|
|
adGenSlotOptionalGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
adGenSlotProdProductID,
|
|
adGenSlotProdTransType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ADTRAN Generic Slot Optional Group."
|
|
::= { adGenSlotMIBGroups 2 }
|
|
|
|
|
|
END
|
|
|
|
|