ADTRAN-GENERIC-OPTICAL-ADD-DROP-MULTIPLEXER-MIB
|
|
|
|
-- TITLE: Generic Optical Add Drop Multiplexer MIB
|
|
-- PRODUCT: MARS-2, VOADM
|
|
-- VERSION: 1.0
|
|
-- DATE: Oct. 10, 2011
|
|
-- AUTHOR: Albert Sue
|
|
-- STATUS: Created
|
|
--
|
|
|
|
DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
|
|
adGenOpticalADM,
|
|
adGenOpticalADMID FROM ADTRAN-SHARED-CND-SYSTEM-MIB
|
|
|
|
InterfaceIndex,
|
|
ifIndex FROM IF-MIB
|
|
|
|
OBJECT-TYPE,
|
|
MODULE-IDENTITY,
|
|
NOTIFICATION-TYPE,
|
|
Integer32,
|
|
IpAddress FROM SNMPv2-SMI
|
|
|
|
TruthValue,
|
|
DisplayString,
|
|
RowStatus FROM SNMPv2-TC
|
|
|
|
adGenSlotInfoIndex FROM ADTRAN-GENSLOT-MIB
|
|
|
|
adTrapInformSeqNum FROM ADTRAN-GENTRAPINFORM-MIB
|
|
sysName FROM SNMPv2-MIB;
|
|
|
|
adGenOpticalADMMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201207260000Z"
|
|
ORGANIZATION "Adtran, Inc."
|
|
CONTACT-INFO
|
|
"CND Tech Support
|
|
Postal: ADTRAN, Inc.
|
|
901 Explorer Blvd.
|
|
Huntsville, AL 35806
|
|
Tel: +1 800 726-8663
|
|
Fax: +1 256 963 6217
|
|
E-mail: support@adtran.com"
|
|
DESCRIPTION
|
|
"This MIB defines the objects for the Generic Optical Add drop Multiplexer MIB."
|
|
|
|
REVISION "201207260000Z"
|
|
DESCRIPTION "Added adGenOpticalADMRemoveAllCrossConnect,
|
|
adGenOpticalADMProvGain,
|
|
adGenOpticalADMInterfaceStatActualGain,
|
|
adGenOpticalADMInterfaceStatInputPower
|
|
"
|
|
REVISION "201206120000Z"
|
|
DESCRIPTION "Added adGenOpticalADMProvChannelAdminStatus and
|
|
adGenOpticalADMCrossConnectAdminStatus"
|
|
|
|
REVISION "201205180000Z"
|
|
DESCRIPTION "Added adGenOpticalADMAlmComOutAmpShutOffClear and
|
|
adGenOpticalADMAlmComOutAmpShutOffActive"
|
|
|
|
REVISION "201204110000Z"
|
|
DESCRIPTION "Added adGenOpticalADMProvChannelWaveLengthMin and
|
|
adGenOpticalADMProvChannelWaveLengthMax"
|
|
|
|
REVISION "201203190000Z"
|
|
DESCRIPTION "Added adGenOpticalADMProvInsertionLoss"
|
|
|
|
REVISION "201201300000Z"
|
|
DESCRIPTION "Created"
|
|
|
|
::= { adGenOpticalADMID 1 }
|
|
|
|
-- ///////////////////////////////////////////////////////
|
|
-- Operation Groups
|
|
-- ///////////////////////////////////////////////////////
|
|
adGenOpticalADMConfiguration OBJECT IDENTIFIER ::= { adGenOpticalADM 1 }
|
|
adGenOpticalADMProvInterface OBJECT IDENTIFIER ::= { adGenOpticalADM 2 }
|
|
adGenOpticalADMProvChannel OBJECT IDENTIFIER ::= { adGenOpticalADM 3 }
|
|
adGenOpticalADMCrossConnect OBJECT IDENTIFIER ::= { adGenOpticalADM 4 }
|
|
adGenOpticalADMProvError OBJECT IDENTIFIER ::= { adGenOpticalADM 5 }
|
|
adGenOpticalADMStatus OBJECT IDENTIFIER ::= { adGenOpticalADM 6 }
|
|
adGenOpticalADMAlarm OBJECT IDENTIFIER ::= { adGenOpticalADM 100 }
|
|
adGenOpticalADMEvents OBJECT IDENTIFIER ::= { adGenOpticalADMAlarm 0}
|
|
|
|
-- //////////////////////////////////////////////////////////////////
|
|
-- adGenOpticalADMConfigration
|
|
-- //////////////////////////////////////////////////////////////////
|
|
adGenOpticalADMConfigurationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenOpticalADMConfigurationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configuration table."
|
|
::= { adGenOpticalADMConfiguration 1 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMConfigurationEntry OBJECT-TYPE
|
|
SYNTAX AdGenOpticalADMConfigurationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table Entry."
|
|
INDEX { adGenSlotInfoIndex }
|
|
::= { adGenOpticalADMConfigurationTable 1 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
AdGenOpticalADMConfigurationEntry ::=
|
|
SEQUENCE {
|
|
adGenOpticalADMGridSpacingSupported BITS,
|
|
adGenOpticalADMRemoveAllCrossConnect INTEGER
|
|
}
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMGridSpacingSupported OBJECT-TYPE
|
|
SYNTAX BITS
|
|
{
|
|
fiftyGHz(0),
|
|
oneHundredGHz(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This shows the supported Grid Spacing.
|
|
Bit positions:
|
|
0 - 50 GHz Grid Spacing supported
|
|
1 - 100 GHz Grid Spacing supported"
|
|
::= { adGenOpticalADMConfigurationEntry 1 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMRemoveAllCrossConnect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
removeAllCrossConnect(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This can be used to remove all Cross Connect at once."
|
|
::= { adGenOpticalADMConfigurationEntry 2 }
|
|
|
|
-- //////////////////////////////////////////////////////////////////
|
|
-- adGenOpticalADMProvInterface
|
|
-- //////////////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvInterfaceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenOpticalADMProvInterfaceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provision Interface table."
|
|
::= { adGenOpticalADMProvInterface 1 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvInterfaceEntry OBJECT-TYPE
|
|
SYNTAX AdGenOpticalADMProvInterfaceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table Entry."
|
|
INDEX { ifIndex }
|
|
::= { adGenOpticalADMProvInterfaceTable 1 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
AdGenOpticalADMProvInterfaceEntry ::=
|
|
SEQUENCE {
|
|
adGenOpticalADMProvInterfaceDescription OCTET STRING,
|
|
adGenOpticalADMProvChannelPowerLevel Integer32,
|
|
adGenOpticalADMProvAutoPowerBalancing INTEGER,
|
|
adGenOpticalADMProvOcmTotalPowerThresholdHigh Integer32,
|
|
adGenOpticalADMProvOcmTotalPowerThresholdLow Integer32,
|
|
adGenOpticalADMProvTotalPowerThresholdHigh Integer32,
|
|
adGenOpticalADMProvTotalPowerThresholdLow Integer32,
|
|
adGenOpticalADMProvInsertionLoss Integer32,
|
|
adGenOpticalADMProvGain Integer32
|
|
}
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvInterfaceDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (1..50))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A short description for this optical interface."
|
|
::= { adGenOpticalADMProvInterfaceEntry 1 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelPowerLevel OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This OID defines the channel power level reference
|
|
for all the channels coming in on ADD-IN or EXP-IN
|
|
interfaces to be auto power balanced. This value
|
|
will be used when auto power balance is enabled"
|
|
::= { adGenOpticalADMProvInterfaceEntry 2 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvAutoPowerBalancing OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(1),
|
|
enable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This OID can be used to set the auto
|
|
power balancing mode on this interface."
|
|
::= { adGenOpticalADMProvInterfaceEntry 3 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvOcmTotalPowerThresholdHigh OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This sets the upper limit of the OCM Power threshold. Once reached,
|
|
an alarm will be issued"
|
|
::= { adGenOpticalADMProvInterfaceEntry 4 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvOcmTotalPowerThresholdLow OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This sets the lower limit of the OCM Power threshold. Once reached,
|
|
an alarm will be issued"
|
|
::= { adGenOpticalADMProvInterfaceEntry 5 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvTotalPowerThresholdHigh OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This sets the upper limit of the Power threshold. Once reached,
|
|
an alarm will be issued"
|
|
::= { adGenOpticalADMProvInterfaceEntry 6 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvTotalPowerThresholdLow OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This sets the lower limit of the Power threshold. Once reached,
|
|
an alarm will be issued"
|
|
::= { adGenOpticalADMProvInterfaceEntry 7 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvInsertionLoss OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This sets the Insertion Loss of connected device."
|
|
::= { adGenOpticalADMProvInterfaceEntry 8 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvGain OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This OID sets the gain of the amplifier"
|
|
::= { adGenOpticalADMProvInterfaceEntry 9 }
|
|
|
|
-- //////////////////////////////////////////////////////////////////
|
|
-- adGenOpticalADMProvInterfaceSupport
|
|
-- //////////////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvInterfaceSupportTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenOpticalADMProvInterfaceSupportEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provision Interface Support table."
|
|
::= { adGenOpticalADMProvInterface 2 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvInterfaceSupportEntry OBJECT-TYPE
|
|
SYNTAX AdGenOpticalADMProvInterfaceSupportEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table Entry."
|
|
INDEX { ifIndex }
|
|
::= { adGenOpticalADMProvInterfaceSupportTable 1 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
AdGenOpticalADMProvInterfaceSupportEntry ::=
|
|
SEQUENCE {
|
|
adGenOpticalADMProvOcmTotalPowerThresholdHighMin Integer32,
|
|
adGenOpticalADMProvOcmTotalPowerThresholdHighMax Integer32,
|
|
adGenOpticalADMProvOcmTotalPowerThresholdLowMin Integer32,
|
|
adGenOpticalADMProvOcmTotalPowerThresholdLowMax Integer32,
|
|
adGenOpticalADMProvTotalPowerThresholdHighMin Integer32,
|
|
adGenOpticalADMProvTotalPowerThresholdHighMax Integer32,
|
|
adGenOpticalADMProvTotalPowerThresholdLowMin Integer32,
|
|
adGenOpticalADMProvTotalPowerThresholdLowMax Integer32
|
|
}
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvOcmTotalPowerThresholdHighMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This retrieves the minimum value of the OCM Total Power threshold high
|
|
that can be set"
|
|
::= { adGenOpticalADMProvInterfaceSupportEntry 1 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvOcmTotalPowerThresholdHighMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This retrieves the maximum value of the OCM Total Power threshold high
|
|
that can be set"
|
|
::= { adGenOpticalADMProvInterfaceSupportEntry 2 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvOcmTotalPowerThresholdLowMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This retrieves the minimum value of the OCM Total Power threshold low
|
|
that can be set"
|
|
::= { adGenOpticalADMProvInterfaceSupportEntry 3 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvOcmTotalPowerThresholdLowMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This retrieves the maximum value of the OCM Total Power threshold low
|
|
that can be set"
|
|
::= { adGenOpticalADMProvInterfaceSupportEntry 4 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvTotalPowerThresholdHighMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This retrieves the minimum value of the Total Power threshold high
|
|
that can be set"
|
|
::= { adGenOpticalADMProvInterfaceSupportEntry 5 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvTotalPowerThresholdHighMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This retrieves the maximum value of the Total Power threshold high
|
|
that can be set"
|
|
::= { adGenOpticalADMProvInterfaceSupportEntry 6 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvTotalPowerThresholdLowMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This retrieves the minimum value of the Total Power threshold low
|
|
that can be set"
|
|
::= { adGenOpticalADMProvInterfaceSupportEntry 7 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvTotalPowerThresholdLowMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This retrieves the maximum value of the Total Power threshold low
|
|
that can be set"
|
|
::= { adGenOpticalADMProvInterfaceSupportEntry 8 }
|
|
|
|
|
|
-- //////////////////////////////////////////////////////////////////
|
|
-- adGenOpticalADMProvChannel
|
|
-- //////////////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenOpticalADMProvChannelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provision Channel table."
|
|
::= { adGenOpticalADMProvChannel 1 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelEntry OBJECT-TYPE
|
|
SYNTAX AdGenOpticalADMProvChannelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table Entry."
|
|
INDEX { ifIndex, adGenOpticalADMProvChannelGridSpacing }
|
|
::= { adGenOpticalADMProvChannelTable 1 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
AdGenOpticalADMProvChannelEntry ::=
|
|
SEQUENCE {
|
|
adGenOpticalADMProvChannelGridSpacing INTEGER,
|
|
adGenOpticalADMProvChannelRowStatus RowStatus,
|
|
adGenOpticalADMProvChannelDescription OCTET STRING,
|
|
adGenOpticalADMProvChannelNumber Integer32,
|
|
adGenOpticalADMProvChannelFrequency Integer32,
|
|
adGenOpticalADMProvChannelWaveLength Integer32,
|
|
adGenOpticalADMProvChannelPowerOverride INTEGER,
|
|
adGenOpticalADMProvChannelPower Integer32,
|
|
adGenOpticalADMProvChannelAttenuation Integer32,
|
|
adGenOpticalADMProvChannelOcmThresholdHigh Integer32,
|
|
adGenOpticalADMProvChannelOcmThresholdLow Integer32,
|
|
adGenOpticalADMProvChannelCrossConnect OCTET STRING,
|
|
adGenOpticalADMProvChannelOperStatus INTEGER,
|
|
adGenOpticalADMProvChannelAdminStatus INTEGER
|
|
}
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelGridSpacing OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
fiftyGHz(50),
|
|
oneHundredGHz(100)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This identifies the Channel Gridspacing associated with this ifIndex."
|
|
::= { adGenOpticalADMProvChannelEntry 1 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to create a new row or modify or delete an
|
|
existing row in the Channel table."
|
|
::= { adGenOpticalADMProvChannelEntry 2 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (1..50))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A short description for this optical channel interface."
|
|
::= { adGenOpticalADMProvChannelEntry 3 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This identifies the Channel Number associated with this ifIndex.
|
|
Values are multiplied by 100.
|
|
Example:
|
|
Channel 17 will be 1700
|
|
Channel 17.25 will be 1725
|
|
Channel 60.5 will be 6050"
|
|
::= { adGenOpticalADMProvChannelEntry 4 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelFrequency OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tera Hz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This identifies the Channel Frequency associated with this ifIndex."
|
|
::= { adGenOpticalADMProvChannelEntry 5 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelWaveLength OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Pico Meters"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This identifies the Channel wavelength associated with this ifIndex."
|
|
::= { adGenOpticalADMProvChannelEntry 6 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelPowerOverride OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disable(1),
|
|
power(2),
|
|
attenuation(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This identifies the Channel Power control associated with this ifIndex.
|
|
This value can be used to set override the power at the channel level."
|
|
::= { adGenOpticalADMProvChannelEntry 7 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This OID can be used to set the channel power level. This
|
|
value will be used if auto power balancing is disabled. The
|
|
channels coming in on ADD-IN or EXP-IN interfaces will be
|
|
attenuated to this power level. This is only used when the
|
|
power control override on the channel level is set to power mode."
|
|
::= { adGenOpticalADMProvChannelEntry 8 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelAttenuation OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dB"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This OID can be used to set the attenuation. This
|
|
value will be used if auto power balancing is disabled and
|
|
the module needs to operate in constant attenuation mode.
|
|
This is only used when the power control override on
|
|
the channel level is set to attenuation mode."
|
|
::= { adGenOpticalADMProvChannelEntry 9 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelOcmThresholdHigh OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This sets the upper limit of the OCM Power threshold. Once reached,
|
|
an alarm will be issued"
|
|
::= { adGenOpticalADMProvChannelEntry 10 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelOcmThresholdLow OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This sets the lower limit of the OCM Power threshold. Once reached,
|
|
an alarm will be issued"
|
|
::= { adGenOpticalADMProvChannelEntry 11 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelCrossConnect OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This string describes display the cross connect name that channel
|
|
is part of. If the channel is not part of any cross connect then
|
|
it will be set to None."
|
|
::= { adGenOpticalADMProvChannelEntry 12 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
up(1),
|
|
down(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This shows the current oper status of the selected Channel."
|
|
::= { adGenOpticalADMProvChannelEntry 13 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
up(1),
|
|
down(2),
|
|
testing(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This sets the administration status of the selected Channel."
|
|
::= { adGenOpticalADMProvChannelEntry 14 }
|
|
|
|
-- //////////////////////////////////////////////////////////////////
|
|
-- adGenOpticalADMProvChannelSupport
|
|
-- //////////////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelSupportTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenOpticalADMProvChannelSupportEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provision Channel table."
|
|
::= { adGenOpticalADMProvChannel 2 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelSupportEntry OBJECT-TYPE
|
|
SYNTAX AdGenOpticalADMProvChannelSupportEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table Entry."
|
|
INDEX { ifIndex, adGenOpticalADMProvChannelGridSpacing }
|
|
::= { adGenOpticalADMProvChannelSupportTable 1 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
AdGenOpticalADMProvChannelSupportEntry ::=
|
|
SEQUENCE {
|
|
adGenOpticalADMProvChannelPowerMin Integer32,
|
|
adGenOpticalADMProvChannelPowerMax Integer32,
|
|
adGenOpticalADMProvChannelAttenuationMin Integer32,
|
|
adGenOpticalADMProvChannelAttenuationMax Integer32,
|
|
adGenOpticalADMProvChannelOcmThresholdHighMin Integer32,
|
|
adGenOpticalADMProvChannelOcmThresholdHighMax Integer32,
|
|
adGenOpticalADMProvChannelOcmThresholdLowMin Integer32,
|
|
adGenOpticalADMProvChannelOcmThresholdLowMax Integer32,
|
|
adGenOpticalADMProvChannelWaveLengthMin Integer32,
|
|
adGenOpticalADMProvChannelWaveLengthMax Integer32
|
|
|
|
}
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelPowerMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This OID retrieves the minimum value of the power level which
|
|
can be set"
|
|
::= { adGenOpticalADMProvChannelSupportEntry 1 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelPowerMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This OID retrieves the maximum value of the power level which
|
|
can be set"
|
|
::= { adGenOpticalADMProvChannelSupportEntry 2 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelAttenuationMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dB"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This OID retrieves the minimum value of the attenuation which
|
|
can be set"
|
|
::= { adGenOpticalADMProvChannelSupportEntry 3 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelAttenuationMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dB"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This OID retrieves the maximum value of the attenuation which
|
|
can be set"
|
|
::= { adGenOpticalADMProvChannelSupportEntry 4 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelOcmThresholdHighMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This retreives the minimum value of the OCM Threshold high
|
|
that can be set"
|
|
::= { adGenOpticalADMProvChannelSupportEntry 5 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelOcmThresholdHighMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This retreives the maximum value of the OCM Threshold high
|
|
that can be set"
|
|
::= { adGenOpticalADMProvChannelSupportEntry 6 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelOcmThresholdLowMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This retreives the minimum value of the OCM Threshold low
|
|
that can be set"
|
|
::= { adGenOpticalADMProvChannelSupportEntry 7 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelOcmThresholdLowMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This retreives the maximum value of the OCM Threshold low
|
|
that can be set"
|
|
::= { adGenOpticalADMProvChannelSupportEntry 8 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelWaveLengthMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "PicoMeter"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This retreives the minimum supported wavelength value."
|
|
::= { adGenOpticalADMProvChannelSupportEntry 9 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelWaveLengthMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "PicoMeter"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This retreives the maximum supported wavelength value."
|
|
::= { adGenOpticalADMProvChannelSupportEntry 10 }
|
|
|
|
-- //////////////////////////////////////////////////////////////////
|
|
-- adGenOpticalADMProvError
|
|
-- //////////////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvErrorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenOpticalADMProvErrorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provision Channel Error table."
|
|
::= { adGenOpticalADMProvError 1 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvErrorEntry OBJECT-TYPE
|
|
SYNTAX AdGenOpticalADMProvErrorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table Entry."
|
|
INDEX { adGenSlotInfoIndex }
|
|
::= { adGenOpticalADMProvErrorTable 1 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
AdGenOpticalADMProvErrorEntry ::=
|
|
SEQUENCE {
|
|
adGenOpticalADMProvChannelError DisplayString,
|
|
adGenOpticalADMProvCrossConnectError DisplayString
|
|
}
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvChannelError OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns information about the last error for the Channel
|
|
creation. This is SLOT indexed. If row creation fails,
|
|
this string will provide details about why the row could
|
|
not be created."
|
|
::= { adGenOpticalADMProvErrorEntry 1 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMProvCrossConnectError OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns information about the last error for the Cross connect
|
|
creation. This is SLOT indexed. If row creation fails,
|
|
this string will provide details about why the row could
|
|
not be created."
|
|
::= { adGenOpticalADMProvErrorEntry 2 }
|
|
|
|
-- //////////////////////////////////////////////////////////////////
|
|
-- adGenOpticalADMCrossConnect
|
|
-- //////////////////////////////////////////////////////////////////
|
|
adGenOpticalADMCrossConnectTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenOpticalADMCrossConnectEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cross Connect table."
|
|
::= { adGenOpticalADMCrossConnect 1 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMCrossConnectEntry OBJECT-TYPE
|
|
SYNTAX AdGenOpticalADMCrossConnectEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table Entry."
|
|
INDEX { adGenSlotInfoIndex, IMPLIED adGenOpticalADMCrossConnectName }
|
|
::= { adGenOpticalADMCrossConnectTable 1 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
AdGenOpticalADMCrossConnectEntry ::=
|
|
SEQUENCE {
|
|
adGenOpticalADMCrossConnectName DisplayString,
|
|
adGenOpticalADMCrossConnectRowStatus RowStatus,
|
|
adGenOpticalADMCrossConnectSrcChannelIfIndex InterfaceIndex,
|
|
adGenOpticalADMCrossConnectSrcChannelGridSpacing INTEGER,
|
|
adGenOpticalADMCrossConnectDstInterfaceIfIndex InterfaceIndex,
|
|
adGenOpticalADMCrossConnectOperationStatus INTEGER,
|
|
adGenOpticalADMCrossConnectError DisplayString,
|
|
adGenOpticalADMCrossConnectAdminStatus INTEGER
|
|
}
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMCrossConnectName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..50))
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This OID specifies the cross connect name. This is a unique name that
|
|
identifies the cross connect in that slot."
|
|
::= { adGenOpticalADMCrossConnectEntry 1 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMCrossConnectRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to create a new row or modify or delete an
|
|
existing row in the Cross Connect table."
|
|
::= { adGenOpticalADMCrossConnectEntry 2 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMCrossConnectSrcChannelIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This ifIndex OID specifies the source slot, optical interface and channel."
|
|
::= { adGenOpticalADMCrossConnectEntry 3 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMCrossConnectSrcChannelGridSpacing OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
fiftyGHz(50),
|
|
oneHundredGHz(100)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This OID specifies the source gridspacing."
|
|
::= { adGenOpticalADMCrossConnectEntry 4 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMCrossConnectDstInterfaceIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This ifIndex OID specifies the destination slot and optical interface."
|
|
::= { adGenOpticalADMCrossConnectEntry 5 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMCrossConnectOperationStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
up(1),
|
|
down(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This OID displays the current Operation Status of this Cross Connect."
|
|
::= { adGenOpticalADMCrossConnectEntry 6 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMCrossConnectError OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This OID displays the error in creating the cross connect. Also during
|
|
operation, this will display any errors that caused operation status to
|
|
go down."
|
|
::= { adGenOpticalADMCrossConnectEntry 7 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMCrossConnectAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
up(1),
|
|
down(2),
|
|
testing(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This sets the administration status of the selected Channel."
|
|
::= { adGenOpticalADMCrossConnectEntry 8 }
|
|
|
|
-- //////////////////////////////////////////////////////////////////
|
|
-- adGenOpticalInterfaceADMStatus
|
|
-- //////////////////////////////////////////////////////////////////
|
|
adGenOpticalADMInterfaceStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenOpticalADMInterfaceStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status table."
|
|
::= { adGenOpticalADMStatus 1 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMInterfaceStatusEntry OBJECT-TYPE
|
|
SYNTAX AdGenOpticalADMInterfaceStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table Interface Entry."
|
|
INDEX { ifIndex }
|
|
::= { adGenOpticalADMInterfaceStatusTable 1 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
AdGenOpticalADMInterfaceStatusEntry ::=
|
|
SEQUENCE {
|
|
adGenOpticalADMInterfaceStatOcmTotalPower Integer32,
|
|
adGenOpticalADMInterfaceStatTotalPower Integer32,
|
|
adGenOpticalADMInterfaceStatActualGain Integer32,
|
|
adGenOpticalADMInterfaceStatInputPower Integer32
|
|
}
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMInterfaceStatOcmTotalPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This displays the Total OCM current power value of the selected index."
|
|
::= { adGenOpticalADMInterfaceStatusEntry 1 }
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMInterfaceStatTotalPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This displays the Total current power value of the selected index."
|
|
::= { adGenOpticalADMInterfaceStatusEntry 2 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMInterfaceStatActualGain OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This displays the power gain of the selected index."
|
|
::= { adGenOpticalADMInterfaceStatusEntry 3 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMInterfaceStatInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This displays the input power of the selected index."
|
|
::= { adGenOpticalADMInterfaceStatusEntry 4 }
|
|
|
|
-- //////////////////////////////////////////////////////////////////
|
|
-- adGenOpticalADMChannelStatus
|
|
-- //////////////////////////////////////////////////////////////////
|
|
adGenOpticalADMChannelStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenOpticalADMChannelStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Channel Status table."
|
|
::= { adGenOpticalADMStatus 2 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMChannelStatusEntry OBJECT-TYPE
|
|
SYNTAX AdGenOpticalADMChannelStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table Channel Entry."
|
|
INDEX { ifIndex, adGenOpticalADMProvChannelGridSpacing }
|
|
::= { adGenOpticalADMChannelStatusTable 1 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
AdGenOpticalADMChannelStatusEntry ::=
|
|
SEQUENCE {
|
|
adGenOpticalADMChannelStatOcmChannelPower Integer32,
|
|
adGenOpticalADMChannelStatAttenuation Integer32
|
|
}
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMChannelStatOcmChannelPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This displays the Channel current power value of the selected index."
|
|
::= { adGenOpticalADMChannelStatusEntry 1 }
|
|
|
|
-- /////////////////////////////////////////////////////////
|
|
adGenOpticalADMChannelStatAttenuation OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Tenth of a dB"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This displays the Channel current attenuation value of the selected index."
|
|
::= { adGenOpticalADMChannelStatusEntry 2 }
|
|
|
|
-- //////////////////////////////////////////////////////////////////
|
|
|
|
-- //////////////////////////////////////////////////////////////////
|
|
-- Alarm Traps
|
|
-- //////////////////////////////////////////////////////////////////
|
|
adGenOpticalADMAlmComInLOSActiveClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-IN Loss of Signal Cleared."
|
|
|
|
--#TYPE "Composite-IN Loss of Signal Cleared."
|
|
--#SUMMARY "Composite-IN Loss of Signal"
|
|
--#SUMMARY "Cleared at shelf: %s, slot: %d, interface %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY CRITICAL
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 1}
|
|
|
|
adGenOpticalADMAlmComInLOSActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-IN Loss of Signal Active."
|
|
|
|
--#TYPE "Composite-IN Loss of Signal Active."
|
|
--#SUMMARY "Composite-IN Loss of Signal"
|
|
--#SUMMARY "Activated at shelf: %s, slot: %d, interface %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY CRITICAL
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 2}
|
|
|
|
-- //////////////////////////////////////////////////////////////////
|
|
adGenOpticalADMAlmComInTotalPwrTHHiActiveClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-IN Total Power Threshold HI Cleared."
|
|
|
|
--#TYPE "Composite-IN Total Power Threshold HI Cleared."
|
|
--#SUMMARY "Composite-IN Total Power Threshold HI"
|
|
--#SUMMARY "Cleared at shelf: %s, slot: %d, interface %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 3}
|
|
|
|
adGenOpticalADMAlmComInTotalPwrTHHiActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-IN Total Power Threshold HI Active."
|
|
|
|
--#TYPE "Composite-IN Total Power Threshold HI Active."
|
|
--#SUMMARY "Composite-IN Total Power Threshold HI"
|
|
--#SUMMARY "Activated at shelf: %s, slot: %d, interface %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 4}
|
|
|
|
|
|
-- //////////////////////////////////////////////////////////////////
|
|
adGenOpticalADMAlmComInTotalPwrTHLowActiveClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-IN Total Power Threshold Low Cleared."
|
|
|
|
--#TYPE "Composite-IN Total Power Threshold Low Cleared."
|
|
--#SUMMARY "Composite-IN Total Power Threshold Low"
|
|
--#SUMMARY "Cleared at shelf: %s, slot: %d, interface %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 5}
|
|
|
|
adGenOpticalADMAlmComInTotalPwrTHLowActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-IN Total Power Threshold Low Active."
|
|
|
|
--#TYPE "Composite-IN Total Power Threshold Low Active."
|
|
--#SUMMARY "Composite-IN Total Power Threshold Low"
|
|
--#SUMMARY "Activated at shelf: %s, slot: %d, interface %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 6}
|
|
|
|
-- //////////////////////////////////////////////////////////////////
|
|
adGenOpticalADMAlmComInOcmTotalPwrTHHiActiveClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-IN OCM Total Power Threshold HI Cleared."
|
|
|
|
--#TYPE "Composite-IN OCM Total Power Threshold HI Cleared."
|
|
--#SUMMARY "Composite-IN OCM Total Power Threshold HI"
|
|
--#SUMMARY "Cleared at shelf: %s, slot: %d, interface %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 7}
|
|
|
|
adGenOpticalADMAlmComInOcmTotalPwrTHHiActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-IN OCM Total Power Threshold HI Active."
|
|
|
|
--#TYPE "Composite-IN OCM Total Power Threshold HI Active."
|
|
--#SUMMARY "Composite-IN OCM Total Power Threshold HI"
|
|
--#SUMMARY "Activated at shelf: %s, slot: %d, interface %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 8}
|
|
|
|
-- //////////////////////////////////////////////////////////////////
|
|
adGenOpticalADMAlmComInOcmTotalPwrTHLowActiveClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-IN Total OCM Power Threshold LOW Cleared."
|
|
|
|
--#TYPE "Composite-IN OCM Total Power Threshold LOW Cleared."
|
|
--#SUMMARY "Composite-IN OCM Total Power Threshold LOW"
|
|
--#SUMMARY "Cleared at shelf: %s, slot: %d, interface %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 9}
|
|
|
|
adGenOpticalADMAlmComInOcmTotalPwrTHLowActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-IN OCM Total Power Threshold LOW Active."
|
|
|
|
--#TYPE "Composite-IN OCM Total Power Threshold LOW Active."
|
|
--#SUMMARY "Composite-IN OCM Total Power Threshold LOW"
|
|
--#SUMMARY "Activated at shelf: %s, slot: %d, interface %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 10}
|
|
|
|
-- //////////////////////////////////////////////////////////////////
|
|
adGenOpticalADMAlmComOutOcmTotalPwrTHHiActiveClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-OUT OCM Total Power Threshold HI Cleared."
|
|
|
|
--#TYPE "Composite-OUT OCM Total Power Threshold HI Cleared."
|
|
--#SUMMARY "Composite-OUT OCM Total Power Threshold HI"
|
|
--#SUMMARY "Cleared at shelf: %s, slot: %d, interface %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 11}
|
|
|
|
adGenOpticalADMAlmComOutOcmTotalPwrTHHiActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-OUT OCM Total Power Threshold HI Active."
|
|
|
|
--#TYPE "Composite-OUT OCM Total Power Threshold HI Active."
|
|
--#SUMMARY "Composite-OUT OCM Total Power Threshold HI"
|
|
--#SUMMARY "Activated at shelf: %s, slot: %d, interface %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 12}
|
|
-- //////////////////////////////////////////////////////////////////
|
|
adGenOpticalADMAlmComOutOcmTotalPwrTHLowActiveClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-OUT OCM Total Power Threshold LOW Cleared."
|
|
|
|
--#TYPE "Composite-OUT OCM Total Power Threshold LOW Cleared."
|
|
--#SUMMARY "Composite-OUT OCM Total Power Threshold LOW"
|
|
--#SUMMARY "Cleared at shelf: %s, slot: %d, interface %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 13}
|
|
|
|
adGenOpticalADMAlmComOutOcmTotalPwrTHLowActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-OUT OCM Total Power Threshold LOW Active."
|
|
|
|
--#TYPE "Composite-OUT OCM Total Power Threshold LOW Active."
|
|
--#SUMMARY "Composite-OUT OCM Total Power Threshold LOW"
|
|
--#SUMMARY "Activated at shelf: %s, slot: %d, interface %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 14}
|
|
-- //////////////////////////////////////////////////////////////////
|
|
adGenOpticalADMAlmChannelComInOcmPwrTHHiActiveClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-IN Channel OCM Power Threshold HI Cleared."
|
|
|
|
--#TYPE "Composite-IN Channel OCM Power Threshold HI Cleared."
|
|
--#SUMMARY "Composite-IN Channel OCM Power Threshold HI"
|
|
--#SUMMARY "Cleared at shelf: %s, slot: %d, com-in channel %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 15}
|
|
|
|
adGenOpticalADMAlmChannelComInOcmPwrTHHiActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-IN Channel OCM Power Threshold HI Active."
|
|
|
|
--#TYPE "Composite-IN Channel OCM Power Threshold HI Active."
|
|
--#SUMMARY "Composite-IN Channel OCM Power Threshold HI"
|
|
--#SUMMARY "Activated at shelf: %s, slot: %d, com-in channel %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 16}
|
|
|
|
-- //////////////////////////////////////////////////////////////////
|
|
adGenOpticalADMAlmChannelComInOcmPwrTHLowActiveClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-IN Channel OCM Power Threshold LOW Cleared."
|
|
|
|
--#TYPE "Composite-IN Channel OCM Power Threshold LOW Cleared."
|
|
--#SUMMARY "Composite-IN Channel OCM Power Threshold LOW"
|
|
--#SUMMARY "Cleared at shelf: %s, slot: %d, com-in channel %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 17}
|
|
|
|
adGenOpticalADMAlmChannelComInOcmPwrTHLowActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-IN Channel OCM Power Threshold LOW Active."
|
|
|
|
--#TYPE "Composite-IN Channel OCM Power Threshold LOW Active."
|
|
--#SUMMARY "Composite-IN Channel OCM Power Threshold LOW"
|
|
--#SUMMARY "Activated at shelf: %s, slot: %d, com-in channel %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 18}
|
|
|
|
-- //////////////////////////////////////////////////////////////////
|
|
adGenOpticalADMAlmChannelComOutOcmPwrTHHiActiveClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-OUT Channel OCM Power Threshold HI Cleared."
|
|
|
|
--#TYPE "Composite-OUT Channel OCM Power Threshold HI Cleared."
|
|
--#SUMMARY "Composite-OUT Channel OCM Power Threshold HI"
|
|
--#SUMMARY "Cleared at shelf: %s, slot: %d, com-out channel %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 19}
|
|
|
|
adGenOpticalADMAlmChannelComOutOcmPwrTHHiActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-OUT Channel OCM Power Threshold HI Active."
|
|
|
|
--#TYPE "Composite-OUT Channel OCM Power Threshold HI Active."
|
|
--#SUMMARY "Composite-OUT Channel OCM Power Threshold HI"
|
|
--#SUMMARY "Activated at shelf: %s, slot: %d, com-out channel %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 20}
|
|
|
|
-- //////////////////////////////////////////////////////////////////
|
|
adGenOpticalADMAlmChannelComOutOcmPwrTHLowActiveClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-OUT Channel OCM Power Threshold LOW Cleared."
|
|
|
|
--#TYPE "Composite-OUT Channel OCM Power Threshold LOW Cleared."
|
|
--#SUMMARY "Composite-OUT Channel OCM Power Threshold LOW"
|
|
--#SUMMARY "Cleared at shelf: %s, slot: %d, com-out channel %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 21}
|
|
|
|
adGenOpticalADMAlmChannelComOutOcmPwrTHLowActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-OUT Channel OCM Power Threshold LOW Active."
|
|
|
|
--#TYPE "Composite-OUT Channel OCM Power Threshold LOW Active."
|
|
--#SUMMARY "Composite-OUT Channel OCM Power Threshold LOW"
|
|
--#SUMMARY "Activated at shelf: %s, slot: %d, com-out channel %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 22}
|
|
|
|
-- //////////////////////////////////////////////////////////////////
|
|
adGenOpticalADMAlmChannelComOutAutoOORHiActiveClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-OUT Channel Auto Power Out Of Range HI Cleared."
|
|
|
|
--#TYPE "Composite-OUT Channel Auto Power Out Of Range HI Cleared."
|
|
--#SUMMARY "Composite-OUT Channel Auto Power Out Of Range HI."
|
|
--#SUMMARY "Cleared at shelf: %s, slot: %d, com-out channel %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 23}
|
|
|
|
adGenOpticalADMAlmChannelComOutAutoOORHiActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-OUT Channel Auto Power Out Of Range HI Active."
|
|
|
|
--#TYPE "Composite-OUT Channel Auto Power Out Of Range HI Active."
|
|
--#SUMMARY "Composite-OUT Channel Auto Power Out Of Range HI."
|
|
--#SUMMARY "Activated at shelf: %s, slot: %d, com-out channel %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 24}
|
|
|
|
-- //////////////////////////////////////////////////////////////////
|
|
adGenOpticalADMAlmChannelComOutAutoOORLowActiveClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-OUT Channel Auto Power Out Of Range LOW Cleared."
|
|
|
|
--#TYPE "Composite-OUT Channel Auto Power Out Of Range LOW Cleared."
|
|
--#SUMMARY "Composite-OUT Channel Auto Power Out Of Range LOW."
|
|
--#SUMMARY "Cleared at shelf: %s, slot: %d, com-out channel %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 25}
|
|
|
|
adGenOpticalADMAlmChannelComOutAutoOORLowActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-OUT Channel Auto Power Out Of Range LOW Active."
|
|
|
|
--#TYPE "Composite-OUT Channel Auto Power Out Of Range LOW Active."
|
|
--#SUMMARY "Composite-OUT Channel Auto Power Out Of Range LOW."
|
|
--#SUMMARY "Activated at shelf: %s, slot: %d, com-out channel %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 26}
|
|
|
|
-- //////////////////////////////////////////////////////////////////
|
|
adGenOpticalADMAlmLossOfMidStageInActiveClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Loss of Mid-Stage In Cleared."
|
|
|
|
--#TYPE "Loss of Mid-Stage In Cleared."
|
|
--#SUMMARY "Power of Mid-Stage In falls below a threshold value."
|
|
--#SUMMARY "Cleared at shelf: %s, slot: %d, Mid-Stage In %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY CRITICAL
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 27}
|
|
|
|
adGenOpticalADMAlmLossOfMidStageInActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Loss of Mid-Stage In Active."
|
|
|
|
--#TYPE "Loss of Mid-Stage In Active."
|
|
--#SUMMARY "Power of Mid-Stage In falls below a threshold value."
|
|
--#SUMMARY "Activated at shelf: %s, slot: %d, Mid-Stage In %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY CRITICAL
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 28}
|
|
|
|
-- //////////////////////////////////////////////////////////////////
|
|
adGenOpticalADMAlmComOutAmpShutOffClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-OUT Amplifier Shut Off Cleared.
|
|
This alarm is cleared, when Booster Amplifier's input
|
|
power falls back into its operational limits."
|
|
--#TYPE "Composite-OUT Amplifier Shut Off Cleared."
|
|
--#SUMMARY "Composite-OUT Amplifier Shut Off Cleared."
|
|
--#SUMMARY "Cleared at shelf: %s, slot: %d, interface %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY CRITICAL
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 29}
|
|
|
|
adGenOpticalADMAlmComOutAmpShutOffActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite-OUT Amplifier Shut Off Active.
|
|
This alarm is issued, when Booster Amplifier's input
|
|
power is outside the operational limits, thus
|
|
causing Amplifier to shut down."
|
|
--#TYPE "Composite-OUT Amplifier Shut Off Active."
|
|
--#SUMMARY "Composite-OUT Amplifier Shut Off Active."
|
|
--#SUMMARY "Activated at shelf: %s, slot: %d, interface %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY CRITICAL
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenOpticalADMEvents 30}
|
|
|
|
|
|
-- //////////////////////////////////////////////////////////////////
|
|
END
|