ADTRAN-GENERIC-OPTICAL-ADD-DROP-MULTIPLEXER-MIB
-- TITLE: Generic Optical Add Drop Multiplexer MIB
-- PRODUCT: MARS-2, VOADM
-- VERSION: 1.0
-- DATE: Oct. 10, 2011
-- AUTHOR: Albert Sue
-- STATUS: Created
--
DEFINITIONS ::= BEGIN
IMPORTS
adGenOpticalADM,
adGenOpticalADMID FROM ADTRAN-SHARED-CND-SYSTEM-MIB
InterfaceIndex,
ifIndex FROM IF-MIB
OBJECT-TYPE,
MODULE-IDENTITY,
NOTIFICATION-TYPE,
Integer32,
IpAddress FROM SNMPv2-SMI
TruthValue,
DisplayString,
RowStatus FROM SNMPv2-TC
adGenSlotInfoIndex FROM ADTRAN-GENSLOT-MIB
adTrapInformSeqNum FROM ADTRAN-GENTRAPINFORM-MIB
sysName FROM SNMPv2-MIB;
adGenOpticalADMMIB MODULE-IDENTITY
LAST-UPDATED "201207260000Z"
ORGANIZATION "Adtran, Inc."
CONTACT-INFO
"CND Tech Support
Postal: ADTRAN, Inc.
901 Explorer Blvd.
Huntsville, AL 35806
Tel: +1 800 726-8663
Fax: +1 256 963 6217
E-mail: support@adtran.com"
DESCRIPTION
"This MIB defines the objects for the Generic Optical Add drop Multiplexer MIB."
REVISION "201207260000Z"
DESCRIPTION "Added adGenOpticalADMRemoveAllCrossConnect,
adGenOpticalADMProvGain,
adGenOpticalADMInterfaceStatActualGain,
adGenOpticalADMInterfaceStatInputPower
"
REVISION "201206120000Z"
DESCRIPTION "Added adGenOpticalADMProvChannelAdminStatus and
adGenOpticalADMCrossConnectAdminStatus"
REVISION "201205180000Z"
DESCRIPTION "Added adGenOpticalADMAlmComOutAmpShutOffClear and
adGenOpticalADMAlmComOutAmpShutOffActive"
REVISION "201204110000Z"
DESCRIPTION "Added adGenOpticalADMProvChannelWaveLengthMin and
adGenOpticalADMProvChannelWaveLengthMax"
REVISION "201203190000Z"
DESCRIPTION "Added adGenOpticalADMProvInsertionLoss"
REVISION "201201300000Z"
DESCRIPTION "Created"
::= { adGenOpticalADMID 1 }
-- ///////////////////////////////////////////////////////
-- Operation Groups
-- ///////////////////////////////////////////////////////
adGenOpticalADMConfiguration OBJECT IDENTIFIER ::= { adGenOpticalADM 1 }
adGenOpticalADMProvInterface OBJECT IDENTIFIER ::= { adGenOpticalADM 2 }
adGenOpticalADMProvChannel OBJECT IDENTIFIER ::= { adGenOpticalADM 3 }
adGenOpticalADMCrossConnect OBJECT IDENTIFIER ::= { adGenOpticalADM 4 }
adGenOpticalADMProvError OBJECT IDENTIFIER ::= { adGenOpticalADM 5 }
adGenOpticalADMStatus OBJECT IDENTIFIER ::= { adGenOpticalADM 6 }
adGenOpticalADMAlarm OBJECT IDENTIFIER ::= { adGenOpticalADM 100 }
adGenOpticalADMEvents OBJECT IDENTIFIER ::= { adGenOpticalADMAlarm 0}
-- //////////////////////////////////////////////////////////////////
-- adGenOpticalADMConfigration
-- //////////////////////////////////////////////////////////////////
adGenOpticalADMConfigurationTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenOpticalADMConfigurationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration table."
::= { adGenOpticalADMConfiguration 1 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMConfigurationEntry OBJECT-TYPE
SYNTAX AdGenOpticalADMConfigurationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry."
INDEX { adGenSlotInfoIndex }
::= { adGenOpticalADMConfigurationTable 1 }
-- /////////////////////////////////////////////////////////
AdGenOpticalADMConfigurationEntry ::=
SEQUENCE {
adGenOpticalADMGridSpacingSupported BITS,
adGenOpticalADMRemoveAllCrossConnect INTEGER
}
-- /////////////////////////////////////////////////////////
adGenOpticalADMGridSpacingSupported OBJECT-TYPE
SYNTAX BITS
{
fiftyGHz(0),
oneHundredGHz(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This shows the supported Grid Spacing.
Bit positions:
0 - 50 GHz Grid Spacing supported
1 - 100 GHz Grid Spacing supported"
::= { adGenOpticalADMConfigurationEntry 1 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMRemoveAllCrossConnect OBJECT-TYPE
SYNTAX INTEGER
{
removeAllCrossConnect(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This can be used to remove all Cross Connect at once."
::= { adGenOpticalADMConfigurationEntry 2 }
-- //////////////////////////////////////////////////////////////////
-- adGenOpticalADMProvInterface
-- //////////////////////////////////////////////////////////////////
adGenOpticalADMProvInterfaceTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenOpticalADMProvInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Provision Interface table."
::= { adGenOpticalADMProvInterface 1 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvInterfaceEntry OBJECT-TYPE
SYNTAX AdGenOpticalADMProvInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry."
INDEX { ifIndex }
::= { adGenOpticalADMProvInterfaceTable 1 }
-- /////////////////////////////////////////////////////////
AdGenOpticalADMProvInterfaceEntry ::=
SEQUENCE {
adGenOpticalADMProvInterfaceDescription OCTET STRING,
adGenOpticalADMProvChannelPowerLevel Integer32,
adGenOpticalADMProvAutoPowerBalancing INTEGER,
adGenOpticalADMProvOcmTotalPowerThresholdHigh Integer32,
adGenOpticalADMProvOcmTotalPowerThresholdLow Integer32,
adGenOpticalADMProvTotalPowerThresholdHigh Integer32,
adGenOpticalADMProvTotalPowerThresholdLow Integer32,
adGenOpticalADMProvInsertionLoss Integer32,
adGenOpticalADMProvGain Integer32
}
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvInterfaceDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..50))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A short description for this optical interface."
::= { adGenOpticalADMProvInterfaceEntry 1 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelPowerLevel OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This OID defines the channel power level reference
for all the channels coming in on ADD-IN or EXP-IN
interfaces to be auto power balanced. This value
will be used when auto power balance is enabled"
::= { adGenOpticalADMProvInterfaceEntry 2 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvAutoPowerBalancing OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This OID can be used to set the auto
power balancing mode on this interface."
::= { adGenOpticalADMProvInterfaceEntry 3 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvOcmTotalPowerThresholdHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This sets the upper limit of the OCM Power threshold. Once reached,
an alarm will be issued"
::= { adGenOpticalADMProvInterfaceEntry 4 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvOcmTotalPowerThresholdLow OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This sets the lower limit of the OCM Power threshold. Once reached,
an alarm will be issued"
::= { adGenOpticalADMProvInterfaceEntry 5 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvTotalPowerThresholdHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This sets the upper limit of the Power threshold. Once reached,
an alarm will be issued"
::= { adGenOpticalADMProvInterfaceEntry 6 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvTotalPowerThresholdLow OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This sets the lower limit of the Power threshold. Once reached,
an alarm will be issued"
::= { adGenOpticalADMProvInterfaceEntry 7 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvInsertionLoss OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This sets the Insertion Loss of connected device."
::= { adGenOpticalADMProvInterfaceEntry 8 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvGain OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This OID sets the gain of the amplifier"
::= { adGenOpticalADMProvInterfaceEntry 9 }
-- //////////////////////////////////////////////////////////////////
-- adGenOpticalADMProvInterfaceSupport
-- //////////////////////////////////////////////////////////////////
adGenOpticalADMProvInterfaceSupportTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenOpticalADMProvInterfaceSupportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Provision Interface Support table."
::= { adGenOpticalADMProvInterface 2 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvInterfaceSupportEntry OBJECT-TYPE
SYNTAX AdGenOpticalADMProvInterfaceSupportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry."
INDEX { ifIndex }
::= { adGenOpticalADMProvInterfaceSupportTable 1 }
-- /////////////////////////////////////////////////////////
AdGenOpticalADMProvInterfaceSupportEntry ::=
SEQUENCE {
adGenOpticalADMProvOcmTotalPowerThresholdHighMin Integer32,
adGenOpticalADMProvOcmTotalPowerThresholdHighMax Integer32,
adGenOpticalADMProvOcmTotalPowerThresholdLowMin Integer32,
adGenOpticalADMProvOcmTotalPowerThresholdLowMax Integer32,
adGenOpticalADMProvTotalPowerThresholdHighMin Integer32,
adGenOpticalADMProvTotalPowerThresholdHighMax Integer32,
adGenOpticalADMProvTotalPowerThresholdLowMin Integer32,
adGenOpticalADMProvTotalPowerThresholdLowMax Integer32
}
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvOcmTotalPowerThresholdHighMin OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This retrieves the minimum value of the OCM Total Power threshold high
that can be set"
::= { adGenOpticalADMProvInterfaceSupportEntry 1 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvOcmTotalPowerThresholdHighMax OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This retrieves the maximum value of the OCM Total Power threshold high
that can be set"
::= { adGenOpticalADMProvInterfaceSupportEntry 2 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvOcmTotalPowerThresholdLowMin OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This retrieves the minimum value of the OCM Total Power threshold low
that can be set"
::= { adGenOpticalADMProvInterfaceSupportEntry 3 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvOcmTotalPowerThresholdLowMax OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This retrieves the maximum value of the OCM Total Power threshold low
that can be set"
::= { adGenOpticalADMProvInterfaceSupportEntry 4 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvTotalPowerThresholdHighMin OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This retrieves the minimum value of the Total Power threshold high
that can be set"
::= { adGenOpticalADMProvInterfaceSupportEntry 5 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvTotalPowerThresholdHighMax OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This retrieves the maximum value of the Total Power threshold high
that can be set"
::= { adGenOpticalADMProvInterfaceSupportEntry 6 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvTotalPowerThresholdLowMin OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This retrieves the minimum value of the Total Power threshold low
that can be set"
::= { adGenOpticalADMProvInterfaceSupportEntry 7 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvTotalPowerThresholdLowMax OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This retrieves the maximum value of the Total Power threshold low
that can be set"
::= { adGenOpticalADMProvInterfaceSupportEntry 8 }
-- //////////////////////////////////////////////////////////////////
-- adGenOpticalADMProvChannel
-- //////////////////////////////////////////////////////////////////
adGenOpticalADMProvChannelTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenOpticalADMProvChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Provision Channel table."
::= { adGenOpticalADMProvChannel 1 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelEntry OBJECT-TYPE
SYNTAX AdGenOpticalADMProvChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry."
INDEX { ifIndex, adGenOpticalADMProvChannelGridSpacing }
::= { adGenOpticalADMProvChannelTable 1 }
-- /////////////////////////////////////////////////////////
AdGenOpticalADMProvChannelEntry ::=
SEQUENCE {
adGenOpticalADMProvChannelGridSpacing INTEGER,
adGenOpticalADMProvChannelRowStatus RowStatus,
adGenOpticalADMProvChannelDescription OCTET STRING,
adGenOpticalADMProvChannelNumber Integer32,
adGenOpticalADMProvChannelFrequency Integer32,
adGenOpticalADMProvChannelWaveLength Integer32,
adGenOpticalADMProvChannelPowerOverride INTEGER,
adGenOpticalADMProvChannelPower Integer32,
adGenOpticalADMProvChannelAttenuation Integer32,
adGenOpticalADMProvChannelOcmThresholdHigh Integer32,
adGenOpticalADMProvChannelOcmThresholdLow Integer32,
adGenOpticalADMProvChannelCrossConnect OCTET STRING,
adGenOpticalADMProvChannelOperStatus INTEGER,
adGenOpticalADMProvChannelAdminStatus INTEGER
}
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelGridSpacing OBJECT-TYPE
SYNTAX INTEGER
{
fiftyGHz(50),
oneHundredGHz(100)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This identifies the Channel Gridspacing associated with this ifIndex."
::= { adGenOpticalADMProvChannelEntry 1 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or modify or delete an
existing row in the Channel table."
::= { adGenOpticalADMProvChannelEntry 2 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..50))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A short description for this optical channel interface."
::= { adGenOpticalADMProvChannelEntry 3 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This identifies the Channel Number associated with this ifIndex.
Values are multiplied by 100.
Example:
Channel 17 will be 1700
Channel 17.25 will be 1725
Channel 60.5 will be 6050"
::= { adGenOpticalADMProvChannelEntry 4 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelFrequency OBJECT-TYPE
SYNTAX Integer32
UNITS "Tera Hz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This identifies the Channel Frequency associated with this ifIndex."
::= { adGenOpticalADMProvChannelEntry 5 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelWaveLength OBJECT-TYPE
SYNTAX Integer32
UNITS "Pico Meters"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This identifies the Channel wavelength associated with this ifIndex."
::= { adGenOpticalADMProvChannelEntry 6 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelPowerOverride OBJECT-TYPE
SYNTAX INTEGER
{
disable(1),
power(2),
attenuation(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This identifies the Channel Power control associated with this ifIndex.
This value can be used to set override the power at the channel level."
::= { adGenOpticalADMProvChannelEntry 7 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelPower OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This OID can be used to set the channel power level. This
value will be used if auto power balancing is disabled. The
channels coming in on ADD-IN or EXP-IN interfaces will be
attenuated to this power level. This is only used when the
power control override on the channel level is set to power mode."
::= { adGenOpticalADMProvChannelEntry 8 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelAttenuation OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This OID can be used to set the attenuation. This
value will be used if auto power balancing is disabled and
the module needs to operate in constant attenuation mode.
This is only used when the power control override on
the channel level is set to attenuation mode."
::= { adGenOpticalADMProvChannelEntry 9 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelOcmThresholdHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This sets the upper limit of the OCM Power threshold. Once reached,
an alarm will be issued"
::= { adGenOpticalADMProvChannelEntry 10 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelOcmThresholdLow OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This sets the lower limit of the OCM Power threshold. Once reached,
an alarm will be issued"
::= { adGenOpticalADMProvChannelEntry 11 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelCrossConnect OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This string describes display the cross connect name that channel
is part of. If the channel is not part of any cross connect then
it will be set to None."
::= { adGenOpticalADMProvChannelEntry 12 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelOperStatus OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This shows the current oper status of the selected Channel."
::= { adGenOpticalADMProvChannelEntry 13 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2),
testing(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This sets the administration status of the selected Channel."
::= { adGenOpticalADMProvChannelEntry 14 }
-- //////////////////////////////////////////////////////////////////
-- adGenOpticalADMProvChannelSupport
-- //////////////////////////////////////////////////////////////////
adGenOpticalADMProvChannelSupportTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenOpticalADMProvChannelSupportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Provision Channel table."
::= { adGenOpticalADMProvChannel 2 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelSupportEntry OBJECT-TYPE
SYNTAX AdGenOpticalADMProvChannelSupportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry."
INDEX { ifIndex, adGenOpticalADMProvChannelGridSpacing }
::= { adGenOpticalADMProvChannelSupportTable 1 }
-- /////////////////////////////////////////////////////////
AdGenOpticalADMProvChannelSupportEntry ::=
SEQUENCE {
adGenOpticalADMProvChannelPowerMin Integer32,
adGenOpticalADMProvChannelPowerMax Integer32,
adGenOpticalADMProvChannelAttenuationMin Integer32,
adGenOpticalADMProvChannelAttenuationMax Integer32,
adGenOpticalADMProvChannelOcmThresholdHighMin Integer32,
adGenOpticalADMProvChannelOcmThresholdHighMax Integer32,
adGenOpticalADMProvChannelOcmThresholdLowMin Integer32,
adGenOpticalADMProvChannelOcmThresholdLowMax Integer32,
adGenOpticalADMProvChannelWaveLengthMin Integer32,
adGenOpticalADMProvChannelWaveLengthMax Integer32
}
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelPowerMin OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This OID retrieves the minimum value of the power level which
can be set"
::= { adGenOpticalADMProvChannelSupportEntry 1 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelPowerMax OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This OID retrieves the maximum value of the power level which
can be set"
::= { adGenOpticalADMProvChannelSupportEntry 2 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelAttenuationMin OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This OID retrieves the minimum value of the attenuation which
can be set"
::= { adGenOpticalADMProvChannelSupportEntry 3 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelAttenuationMax OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This OID retrieves the maximum value of the attenuation which
can be set"
::= { adGenOpticalADMProvChannelSupportEntry 4 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelOcmThresholdHighMin OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This retreives the minimum value of the OCM Threshold high
that can be set"
::= { adGenOpticalADMProvChannelSupportEntry 5 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelOcmThresholdHighMax OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This retreives the maximum value of the OCM Threshold high
that can be set"
::= { adGenOpticalADMProvChannelSupportEntry 6 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelOcmThresholdLowMin OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This retreives the minimum value of the OCM Threshold low
that can be set"
::= { adGenOpticalADMProvChannelSupportEntry 7 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelOcmThresholdLowMax OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This retreives the maximum value of the OCM Threshold low
that can be set"
::= { adGenOpticalADMProvChannelSupportEntry 8 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelWaveLengthMin OBJECT-TYPE
SYNTAX Integer32
UNITS "PicoMeter"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This retreives the minimum supported wavelength value."
::= { adGenOpticalADMProvChannelSupportEntry 9 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelWaveLengthMax OBJECT-TYPE
SYNTAX Integer32
UNITS "PicoMeter"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This retreives the maximum supported wavelength value."
::= { adGenOpticalADMProvChannelSupportEntry 10 }
-- //////////////////////////////////////////////////////////////////
-- adGenOpticalADMProvError
-- //////////////////////////////////////////////////////////////////
adGenOpticalADMProvErrorTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenOpticalADMProvErrorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Provision Channel Error table."
::= { adGenOpticalADMProvError 1 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvErrorEntry OBJECT-TYPE
SYNTAX AdGenOpticalADMProvErrorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry."
INDEX { adGenSlotInfoIndex }
::= { adGenOpticalADMProvErrorTable 1 }
-- /////////////////////////////////////////////////////////
AdGenOpticalADMProvErrorEntry ::=
SEQUENCE {
adGenOpticalADMProvChannelError DisplayString,
adGenOpticalADMProvCrossConnectError DisplayString
}
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvChannelError OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns information about the last error for the Channel
creation. This is SLOT indexed. If row creation fails,
this string will provide details about why the row could
not be created."
::= { adGenOpticalADMProvErrorEntry 1 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMProvCrossConnectError OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns information about the last error for the Cross connect
creation. This is SLOT indexed. If row creation fails,
this string will provide details about why the row could
not be created."
::= { adGenOpticalADMProvErrorEntry 2 }
-- //////////////////////////////////////////////////////////////////
-- adGenOpticalADMCrossConnect
-- //////////////////////////////////////////////////////////////////
adGenOpticalADMCrossConnectTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenOpticalADMCrossConnectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cross Connect table."
::= { adGenOpticalADMCrossConnect 1 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMCrossConnectEntry OBJECT-TYPE
SYNTAX AdGenOpticalADMCrossConnectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry."
INDEX { adGenSlotInfoIndex, IMPLIED adGenOpticalADMCrossConnectName }
::= { adGenOpticalADMCrossConnectTable 1 }
-- /////////////////////////////////////////////////////////
AdGenOpticalADMCrossConnectEntry ::=
SEQUENCE {
adGenOpticalADMCrossConnectName DisplayString,
adGenOpticalADMCrossConnectRowStatus RowStatus,
adGenOpticalADMCrossConnectSrcChannelIfIndex InterfaceIndex,
adGenOpticalADMCrossConnectSrcChannelGridSpacing INTEGER,
adGenOpticalADMCrossConnectDstInterfaceIfIndex InterfaceIndex,
adGenOpticalADMCrossConnectOperationStatus INTEGER,
adGenOpticalADMCrossConnectError DisplayString,
adGenOpticalADMCrossConnectAdminStatus INTEGER
}
-- /////////////////////////////////////////////////////////
adGenOpticalADMCrossConnectName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..50))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This OID specifies the cross connect name. This is a unique name that
identifies the cross connect in that slot."
::= { adGenOpticalADMCrossConnectEntry 1 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMCrossConnectRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or modify or delete an
existing row in the Cross Connect table."
::= { adGenOpticalADMCrossConnectEntry 2 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMCrossConnectSrcChannelIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This ifIndex OID specifies the source slot, optical interface and channel."
::= { adGenOpticalADMCrossConnectEntry 3 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMCrossConnectSrcChannelGridSpacing OBJECT-TYPE
SYNTAX INTEGER
{
fiftyGHz(50),
oneHundredGHz(100)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This OID specifies the source gridspacing."
::= { adGenOpticalADMCrossConnectEntry 4 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMCrossConnectDstInterfaceIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This ifIndex OID specifies the destination slot and optical interface."
::= { adGenOpticalADMCrossConnectEntry 5 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMCrossConnectOperationStatus OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This OID displays the current Operation Status of this Cross Connect."
::= { adGenOpticalADMCrossConnectEntry 6 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMCrossConnectError OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This OID displays the error in creating the cross connect. Also during
operation, this will display any errors that caused operation status to
go down."
::= { adGenOpticalADMCrossConnectEntry 7 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMCrossConnectAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2),
testing(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This sets the administration status of the selected Channel."
::= { adGenOpticalADMCrossConnectEntry 8 }
-- //////////////////////////////////////////////////////////////////
-- adGenOpticalInterfaceADMStatus
-- //////////////////////////////////////////////////////////////////
adGenOpticalADMInterfaceStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenOpticalADMInterfaceStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Status table."
::= { adGenOpticalADMStatus 1 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMInterfaceStatusEntry OBJECT-TYPE
SYNTAX AdGenOpticalADMInterfaceStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Interface Entry."
INDEX { ifIndex }
::= { adGenOpticalADMInterfaceStatusTable 1 }
-- /////////////////////////////////////////////////////////
AdGenOpticalADMInterfaceStatusEntry ::=
SEQUENCE {
adGenOpticalADMInterfaceStatOcmTotalPower Integer32,
adGenOpticalADMInterfaceStatTotalPower Integer32,
adGenOpticalADMInterfaceStatActualGain Integer32,
adGenOpticalADMInterfaceStatInputPower Integer32
}
-- /////////////////////////////////////////////////////////
adGenOpticalADMInterfaceStatOcmTotalPower OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This displays the Total OCM current power value of the selected index."
::= { adGenOpticalADMInterfaceStatusEntry 1 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMInterfaceStatTotalPower OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This displays the Total current power value of the selected index."
::= { adGenOpticalADMInterfaceStatusEntry 2 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMInterfaceStatActualGain OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This displays the power gain of the selected index."
::= { adGenOpticalADMInterfaceStatusEntry 3 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMInterfaceStatInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This displays the input power of the selected index."
::= { adGenOpticalADMInterfaceStatusEntry 4 }
-- //////////////////////////////////////////////////////////////////
-- adGenOpticalADMChannelStatus
-- //////////////////////////////////////////////////////////////////
adGenOpticalADMChannelStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenOpticalADMChannelStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Channel Status table."
::= { adGenOpticalADMStatus 2 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMChannelStatusEntry OBJECT-TYPE
SYNTAX AdGenOpticalADMChannelStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Channel Entry."
INDEX { ifIndex, adGenOpticalADMProvChannelGridSpacing }
::= { adGenOpticalADMChannelStatusTable 1 }
-- /////////////////////////////////////////////////////////
AdGenOpticalADMChannelStatusEntry ::=
SEQUENCE {
adGenOpticalADMChannelStatOcmChannelPower Integer32,
adGenOpticalADMChannelStatAttenuation Integer32
}
-- /////////////////////////////////////////////////////////
adGenOpticalADMChannelStatOcmChannelPower OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This displays the Channel current power value of the selected index."
::= { adGenOpticalADMChannelStatusEntry 1 }
-- /////////////////////////////////////////////////////////
adGenOpticalADMChannelStatAttenuation OBJECT-TYPE
SYNTAX Integer32
UNITS "Tenth of a dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This displays the Channel current attenuation value of the selected index."
::= { adGenOpticalADMChannelStatusEntry 2 }
-- //////////////////////////////////////////////////////////////////
-- //////////////////////////////////////////////////////////////////
-- Alarm Traps
-- //////////////////////////////////////////////////////////////////
adGenOpticalADMAlmComInLOSActiveClear NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-IN Loss of Signal Cleared."
--#TYPE "Composite-IN Loss of Signal Cleared."
--#SUMMARY "Composite-IN Loss of Signal"
--#SUMMARY "Cleared at shelf: %s, slot: %d, interface %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY CRITICAL
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 1}
adGenOpticalADMAlmComInLOSActive NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-IN Loss of Signal Active."
--#TYPE "Composite-IN Loss of Signal Active."
--#SUMMARY "Composite-IN Loss of Signal"
--#SUMMARY "Activated at shelf: %s, slot: %d, interface %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY CRITICAL
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 2}
-- //////////////////////////////////////////////////////////////////
adGenOpticalADMAlmComInTotalPwrTHHiActiveClear NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-IN Total Power Threshold HI Cleared."
--#TYPE "Composite-IN Total Power Threshold HI Cleared."
--#SUMMARY "Composite-IN Total Power Threshold HI"
--#SUMMARY "Cleared at shelf: %s, slot: %d, interface %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 3}
adGenOpticalADMAlmComInTotalPwrTHHiActive NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-IN Total Power Threshold HI Active."
--#TYPE "Composite-IN Total Power Threshold HI Active."
--#SUMMARY "Composite-IN Total Power Threshold HI"
--#SUMMARY "Activated at shelf: %s, slot: %d, interface %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 4}
-- //////////////////////////////////////////////////////////////////
adGenOpticalADMAlmComInTotalPwrTHLowActiveClear NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-IN Total Power Threshold Low Cleared."
--#TYPE "Composite-IN Total Power Threshold Low Cleared."
--#SUMMARY "Composite-IN Total Power Threshold Low"
--#SUMMARY "Cleared at shelf: %s, slot: %d, interface %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 5}
adGenOpticalADMAlmComInTotalPwrTHLowActive NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-IN Total Power Threshold Low Active."
--#TYPE "Composite-IN Total Power Threshold Low Active."
--#SUMMARY "Composite-IN Total Power Threshold Low"
--#SUMMARY "Activated at shelf: %s, slot: %d, interface %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 6}
-- //////////////////////////////////////////////////////////////////
adGenOpticalADMAlmComInOcmTotalPwrTHHiActiveClear NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-IN OCM Total Power Threshold HI Cleared."
--#TYPE "Composite-IN OCM Total Power Threshold HI Cleared."
--#SUMMARY "Composite-IN OCM Total Power Threshold HI"
--#SUMMARY "Cleared at shelf: %s, slot: %d, interface %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 7}
adGenOpticalADMAlmComInOcmTotalPwrTHHiActive NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-IN OCM Total Power Threshold HI Active."
--#TYPE "Composite-IN OCM Total Power Threshold HI Active."
--#SUMMARY "Composite-IN OCM Total Power Threshold HI"
--#SUMMARY "Activated at shelf: %s, slot: %d, interface %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 8}
-- //////////////////////////////////////////////////////////////////
adGenOpticalADMAlmComInOcmTotalPwrTHLowActiveClear NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-IN Total OCM Power Threshold LOW Cleared."
--#TYPE "Composite-IN OCM Total Power Threshold LOW Cleared."
--#SUMMARY "Composite-IN OCM Total Power Threshold LOW"
--#SUMMARY "Cleared at shelf: %s, slot: %d, interface %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 9}
adGenOpticalADMAlmComInOcmTotalPwrTHLowActive NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-IN OCM Total Power Threshold LOW Active."
--#TYPE "Composite-IN OCM Total Power Threshold LOW Active."
--#SUMMARY "Composite-IN OCM Total Power Threshold LOW"
--#SUMMARY "Activated at shelf: %s, slot: %d, interface %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 10}
-- //////////////////////////////////////////////////////////////////
adGenOpticalADMAlmComOutOcmTotalPwrTHHiActiveClear NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-OUT OCM Total Power Threshold HI Cleared."
--#TYPE "Composite-OUT OCM Total Power Threshold HI Cleared."
--#SUMMARY "Composite-OUT OCM Total Power Threshold HI"
--#SUMMARY "Cleared at shelf: %s, slot: %d, interface %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 11}
adGenOpticalADMAlmComOutOcmTotalPwrTHHiActive NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-OUT OCM Total Power Threshold HI Active."
--#TYPE "Composite-OUT OCM Total Power Threshold HI Active."
--#SUMMARY "Composite-OUT OCM Total Power Threshold HI"
--#SUMMARY "Activated at shelf: %s, slot: %d, interface %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 12}
-- //////////////////////////////////////////////////////////////////
adGenOpticalADMAlmComOutOcmTotalPwrTHLowActiveClear NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-OUT OCM Total Power Threshold LOW Cleared."
--#TYPE "Composite-OUT OCM Total Power Threshold LOW Cleared."
--#SUMMARY "Composite-OUT OCM Total Power Threshold LOW"
--#SUMMARY "Cleared at shelf: %s, slot: %d, interface %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 13}
adGenOpticalADMAlmComOutOcmTotalPwrTHLowActive NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-OUT OCM Total Power Threshold LOW Active."
--#TYPE "Composite-OUT OCM Total Power Threshold LOW Active."
--#SUMMARY "Composite-OUT OCM Total Power Threshold LOW"
--#SUMMARY "Activated at shelf: %s, slot: %d, interface %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 14}
-- //////////////////////////////////////////////////////////////////
adGenOpticalADMAlmChannelComInOcmPwrTHHiActiveClear NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-IN Channel OCM Power Threshold HI Cleared."
--#TYPE "Composite-IN Channel OCM Power Threshold HI Cleared."
--#SUMMARY "Composite-IN Channel OCM Power Threshold HI"
--#SUMMARY "Cleared at shelf: %s, slot: %d, com-in channel %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 15}
adGenOpticalADMAlmChannelComInOcmPwrTHHiActive NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-IN Channel OCM Power Threshold HI Active."
--#TYPE "Composite-IN Channel OCM Power Threshold HI Active."
--#SUMMARY "Composite-IN Channel OCM Power Threshold HI"
--#SUMMARY "Activated at shelf: %s, slot: %d, com-in channel %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 16}
-- //////////////////////////////////////////////////////////////////
adGenOpticalADMAlmChannelComInOcmPwrTHLowActiveClear NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-IN Channel OCM Power Threshold LOW Cleared."
--#TYPE "Composite-IN Channel OCM Power Threshold LOW Cleared."
--#SUMMARY "Composite-IN Channel OCM Power Threshold LOW"
--#SUMMARY "Cleared at shelf: %s, slot: %d, com-in channel %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 17}
adGenOpticalADMAlmChannelComInOcmPwrTHLowActive NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-IN Channel OCM Power Threshold LOW Active."
--#TYPE "Composite-IN Channel OCM Power Threshold LOW Active."
--#SUMMARY "Composite-IN Channel OCM Power Threshold LOW"
--#SUMMARY "Activated at shelf: %s, slot: %d, com-in channel %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 18}
-- //////////////////////////////////////////////////////////////////
adGenOpticalADMAlmChannelComOutOcmPwrTHHiActiveClear NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-OUT Channel OCM Power Threshold HI Cleared."
--#TYPE "Composite-OUT Channel OCM Power Threshold HI Cleared."
--#SUMMARY "Composite-OUT Channel OCM Power Threshold HI"
--#SUMMARY "Cleared at shelf: %s, slot: %d, com-out channel %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 19}
adGenOpticalADMAlmChannelComOutOcmPwrTHHiActive NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-OUT Channel OCM Power Threshold HI Active."
--#TYPE "Composite-OUT Channel OCM Power Threshold HI Active."
--#SUMMARY "Composite-OUT Channel OCM Power Threshold HI"
--#SUMMARY "Activated at shelf: %s, slot: %d, com-out channel %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 20}
-- //////////////////////////////////////////////////////////////////
adGenOpticalADMAlmChannelComOutOcmPwrTHLowActiveClear NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-OUT Channel OCM Power Threshold LOW Cleared."
--#TYPE "Composite-OUT Channel OCM Power Threshold LOW Cleared."
--#SUMMARY "Composite-OUT Channel OCM Power Threshold LOW"
--#SUMMARY "Cleared at shelf: %s, slot: %d, com-out channel %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 21}
adGenOpticalADMAlmChannelComOutOcmPwrTHLowActive NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-OUT Channel OCM Power Threshold LOW Active."
--#TYPE "Composite-OUT Channel OCM Power Threshold LOW Active."
--#SUMMARY "Composite-OUT Channel OCM Power Threshold LOW"
--#SUMMARY "Activated at shelf: %s, slot: %d, com-out channel %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 22}
-- //////////////////////////////////////////////////////////////////
adGenOpticalADMAlmChannelComOutAutoOORHiActiveClear NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-OUT Channel Auto Power Out Of Range HI Cleared."
--#TYPE "Composite-OUT Channel Auto Power Out Of Range HI Cleared."
--#SUMMARY "Composite-OUT Channel Auto Power Out Of Range HI."
--#SUMMARY "Cleared at shelf: %s, slot: %d, com-out channel %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 23}
adGenOpticalADMAlmChannelComOutAutoOORHiActive NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-OUT Channel Auto Power Out Of Range HI Active."
--#TYPE "Composite-OUT Channel Auto Power Out Of Range HI Active."
--#SUMMARY "Composite-OUT Channel Auto Power Out Of Range HI."
--#SUMMARY "Activated at shelf: %s, slot: %d, com-out channel %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 24}
-- //////////////////////////////////////////////////////////////////
adGenOpticalADMAlmChannelComOutAutoOORLowActiveClear NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-OUT Channel Auto Power Out Of Range LOW Cleared."
--#TYPE "Composite-OUT Channel Auto Power Out Of Range LOW Cleared."
--#SUMMARY "Composite-OUT Channel Auto Power Out Of Range LOW."
--#SUMMARY "Cleared at shelf: %s, slot: %d, com-out channel %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 25}
adGenOpticalADMAlmChannelComOutAutoOORLowActive NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-OUT Channel Auto Power Out Of Range LOW Active."
--#TYPE "Composite-OUT Channel Auto Power Out Of Range LOW Active."
--#SUMMARY "Composite-OUT Channel Auto Power Out Of Range LOW."
--#SUMMARY "Activated at shelf: %s, slot: %d, com-out channel %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 26}
-- //////////////////////////////////////////////////////////////////
adGenOpticalADMAlmLossOfMidStageInActiveClear NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Loss of Mid-Stage In Cleared."
--#TYPE "Loss of Mid-Stage In Cleared."
--#SUMMARY "Power of Mid-Stage In falls below a threshold value."
--#SUMMARY "Cleared at shelf: %s, slot: %d, Mid-Stage In %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY CRITICAL
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 27}
adGenOpticalADMAlmLossOfMidStageInActive NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Loss of Mid-Stage In Active."
--#TYPE "Loss of Mid-Stage In Active."
--#SUMMARY "Power of Mid-Stage In falls below a threshold value."
--#SUMMARY "Activated at shelf: %s, slot: %d, Mid-Stage In %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY CRITICAL
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 28}
-- //////////////////////////////////////////////////////////////////
adGenOpticalADMAlmComOutAmpShutOffClear NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-OUT Amplifier Shut Off Cleared.
This alarm is cleared, when Booster Amplifier's input
power falls back into its operational limits."
--#TYPE "Composite-OUT Amplifier Shut Off Cleared."
--#SUMMARY "Composite-OUT Amplifier Shut Off Cleared."
--#SUMMARY "Cleared at shelf: %s, slot: %d, interface %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY CRITICAL
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 29}
adGenOpticalADMAlmComOutAmpShutOffActive NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex,
ifIndex
}
STATUS current
DESCRIPTION "Composite-OUT Amplifier Shut Off Active.
This alarm is issued, when Booster Amplifier's input
power is outside the operational limits, thus
causing Amplifier to shut down."
--#TYPE "Composite-OUT Amplifier Shut Off Active."
--#SUMMARY "Composite-OUT Amplifier Shut Off Active."
--#SUMMARY "Activated at shelf: %s, slot: %d, interface %d"
--#ARGUMENTS {1,2,3}
--#SEVERITY CRITICAL
--#GENERIC 6
--#CATEGORY "Alarm Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= {adGenOpticalADMEvents 30}
-- //////////////////////////////////////////////////////////////////
END