ADTRAN-GENDS3TEST-MIB DEFINITIONS ::= BEGIN
|
||
|
||
-- TITLE: Generic DS3 TEST MIB
|
||
-- PRODUCT: All ADTRAN DS3 PRODUCTS
|
||
-- VERSION: 1.0
|
||
-- DATE: 4/10/2008
|
||
-- AUTHOR: Tim Cox
|
||
-- STATUS: PRELIMINARY
|
||
-- MIB ARC: adtran.adShared.adGenDS3Test
|
||
|
||
-- HISTORY:
|
||
-- 04/10/08 twc STATUS: PRELIMINARY.
|
||
-- 04/24/08 jlb Cleaned up compiling errors. Linked the MIB into the adDS3 shared branch of the MIB tree.
|
||
-- Fixed some data type mismatches. Added the MIB groups.
|
||
-- 05/05/08 jlb Changed some data types to make more sense.
|
||
-- 06/19/08 jlb Fixed compiler errors.
|
||
|
||
-- ******************************************************************************************
|
||
|
||
IMPORTS
|
||
Gauge32,
|
||
TimeTicks,
|
||
Unsigned32,
|
||
Integer32,
|
||
OBJECT-TYPE,
|
||
MODULE-IDENTITY,
|
||
NOTIFICATION-TYPE
|
||
FROM SNMPv2-SMI
|
||
OBJECT-GROUP,
|
||
NOTIFICATION-GROUP
|
||
FROM SNMPv2-CONF
|
||
sysName
|
||
FROM SNMPv2-MIB
|
||
DisplayString
|
||
FROM SNMPv2-TC
|
||
ifIndex
|
||
FROM IF-MIB
|
||
adTrapInformSeqNum
|
||
FROM ADTRAN-GENTRAPINFORM-MIB
|
||
adGenSlotInfoIndex
|
||
FROM ADTRAN-GENSLOT-MIB
|
||
adGenPortTrapIdentifier
|
||
FROM ADTRAN-GENPORT-MIB
|
||
adGenDS3Test,
|
||
adGenDS3TestID
|
||
FROM ADTRAN-SHARED-DS3-MIB
|
||
;
|
||
|
||
-- DS3 Test Group
|
||
adGenDS3TestIdentity MODULE-IDENTITY
|
||
LAST-UPDATED "200804100000Z"
|
||
ORGANIZATION "Adtran, Inc."
|
||
CONTACT-INFO "http://www.adtran.com"
|
||
DESCRIPTION
|
||
"The MIB module describing generic objects used for DS3 testing for any
|
||
DS3 product developed by ADTRAN, Inc."
|
||
REVISION "200804100000Z"
|
||
DESCRIPTION "Created"
|
||
::= { adGenDS3TestID 1 }
|
||
|
||
-- OBJECT IDENTIFIERS
|
||
--adGenDS3TestIndex OBJECT IDENTIFIER ::= {adGenDS3Test 1}
|
||
adGenDS3TestCommand OBJECT IDENTIFIER ::= {adGenDS3Test 2}
|
||
adGenDS3TestNearEndLoopback OBJECT IDENTIFIER ::= {adGenDS3Test 3}
|
||
adGenDS3TestFarEndLoopback OBJECT IDENTIFIER ::= {adGenDS3Test 4}
|
||
adGenDS3TestPattern OBJECT IDENTIFIER ::= {adGenDS3Test 5}
|
||
adGenDS3TestMibConformance OBJECT IDENTIFIER ::= {adGenDS3Test 6}
|
||
adGenDS3TestMibGroups OBJECT IDENTIFIER ::= {adGenDS3TestMibConformance 1 }
|
||
|
||
--adGenDS3TestAlarmsPrefix OBJECT IDENTIFIER ::= {adGenDS3Test 10}
|
||
--adGenDS3TestAlarms OBJECT IDENTIFIER ::= {adGenDS3TestAlarmsPrefix 0}
|
||
|
||
|
||
-- ******************************************************************************************
|
||
-- Index
|
||
-- ******************************************************************************************
|
||
|
||
-- ******************************************************************************************
|
||
-- DS3 Test Command Table
|
||
-- ******************************************************************************************
|
||
|
||
adGenDS3TestCommandTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF AdGenDS3TestCommandEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This table supports DS3 test command parameters."
|
||
::= { adGenDS3TestCommand 1 }
|
||
|
||
adGenDS3TestCommandEntry OBJECT-TYPE
|
||
SYNTAX AdGenDS3TestCommandEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An entry in the adGenDS3TestCommandTable."
|
||
INDEX { ifIndex }
|
||
::= { adGenDS3TestCommandTable 1 }
|
||
|
||
AdGenDS3TestCommandEntry ::=
|
||
SEQUENCE
|
||
{
|
||
adGenDS3TestTimeout Integer32,
|
||
adGenDS3TestStartStop INTEGER,
|
||
adGenDS3TestStatus INTEGER,
|
||
adGenDS3TestTimeRemaining Unsigned32,
|
||
adGenDS3TestTimeElapsed Unsigned32
|
||
}
|
||
|
||
adGenDS3TestTimeout OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"- This object defines the number of minutes that any near end or any far end test will
|
||
be run.
|
||
- Any locally initiated loopback or BERT, any local response to a remotely requested
|
||
loopback, and any local request for a far end loopback are all considered tests.
|
||
- Unless a customer requires otherwise, this value will be programmed from 0 to
|
||
9999 minutes. This allows a reasonable 6+ days for a test and reasonably limits
|
||
the required display space on GUIs.
|
||
- A value of 0 disables the timeout so that a test will run indefinitely, if not
|
||
manually stopped."
|
||
::= { adGenDS3TestCommandEntry 1 }
|
||
|
||
adGenDS3TestStartStop OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
nearEndStart(1),
|
||
farEndStart(2),
|
||
allStop(3)
|
||
}
|
||
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
nearEndStart - INITIALIZES and starts any near end test and counters
|
||
farEndStart - INITIALIZES and starts any far end test and counters
|
||
allStop - terminates all tests and freezes status counters of all tests."
|
||
|
||
::= { adGenDS3TestCommandEntry 2 }
|
||
|
||
adGenDS3TestStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(1),
|
||
nearEndLine(2),
|
||
nearEndPayload(3),
|
||
nearEndLineFEAC(4),
|
||
farEndPatt2to23(5),
|
||
farEndPatt2to20(6),
|
||
farEndPatt2to15(7),
|
||
farEndPatt2to23LineLpbk(8),
|
||
farEndPatt2to20LineLpbk(9),
|
||
farEndPatt2to15LineLpbk(10),
|
||
farEndLineLpbk(11)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"None <20> no near end and no far end tests are in progress.
|
||
NearEndLineLpbk <20> a near end locally initiated DS3 line loopback test is in
|
||
progress.
|
||
NearEndPayloadLpbk <20> a near end locally initiated DS3 payload loopback test is in
|
||
progress.
|
||
NearEndLineFEACLpbk <20> an incoming FEAC containing the DS3 Line Loopback request
|
||
initiatedthe DS3 line loopback that is currently in progress.
|
||
FarEndPatt2to23 <20> XNOR of 18th and 23rd stage outputs feed back into 1st stage
|
||
input.
|
||
FarEndPatt2to20 - XOR of 17th and 20th stage outputs feed back into 1st stage
|
||
input.
|
||
FarEndPatt2to15 <20> XNOR of 14th and 15th stage outputs feed back into 1st stage
|
||
input.
|
||
farEndPatt2to23LineLpbk - both far end 2^23 and far end DS3 line loopback are progress.
|
||
farEndPatt2to20LineLpbk - both far end 2^20 and far end DS3 line loopback are progress.
|
||
farEndPatt2to15LineLpbk - both far end 2^15 and far end DS3 line loopback are progress."
|
||
|
||
::= { adGenDS3TestCommandEntry 3 }
|
||
|
||
adGenDS3TestTimeRemaining OBJECT-TYPE
|
||
SYNTAX Unsigned32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Initialized to adGenDS3TestTimeout upon reception of a Start object.
|
||
0 <20> occurs when near end test has ended.
|
||
0 <20> occurs when near end test is in progress, but timeout has been disabled.
|
||
>0 <20> occurs when near end test is in progress, but timeout has not been disabled."
|
||
|
||
::= { adGenDS3TestCommandEntry 4 }
|
||
|
||
adGenDS3TestTimeElapsed OBJECT-TYPE
|
||
SYNTAX Unsigned32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 - initialization value at instance a test starts.
|
||
>0 <20> occurs when near end test is in progress or just ended."
|
||
::= { adGenDS3TestCommandEntry 5 }
|
||
|
||
-- ******************************************************************************************
|
||
-- DS3 Test Near End Loopback Table
|
||
-- ******************************************************************************************
|
||
|
||
adGenDS3TestNearEndLoopbackTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF AdGenDS3TestNearEndLoopbackEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This table supports DS3 Test Near End Loopback parameters."
|
||
::= { adGenDS3TestNearEndLoopback 1 }
|
||
|
||
adGenDS3TestNearEndLoopbackEntry OBJECT-TYPE
|
||
SYNTAX AdGenDS3TestNearEndLoopbackEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An entry in the adGenDS3TestNearEndLoopbackTable."
|
||
INDEX { ifIndex }
|
||
::= { adGenDS3TestNearEndLoopbackTable 1 }
|
||
|
||
AdGenDS3TestNearEndLoopbackEntry ::=
|
||
SEQUENCE
|
||
{
|
||
adGenDS3TestNearEndLoopbackType INTEGER
|
||
}
|
||
|
||
adGenDS3TestNearEndLoopbackType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
line(1),
|
||
payload(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"- This object selects the near end loopback that will be executed upon recognition of
|
||
a start test.
|
||
- This object should be ignored if issued while any test is in progress.
|
||
- line - indicates that the incoming DS3 will be looped back at a point such that
|
||
the outgoing positive and negative pulses correlate with the polarity of
|
||
the incoming positive and negative pulses.
|
||
- payload - indicates that the incoming DS3 payload will be looped back toward the DS3
|
||
interface, while the outgoing overhead will be regenerated by a DS3
|
||
transmit framer."
|
||
::= { adGenDS3TestNearEndLoopbackEntry 1 }
|
||
|
||
-- ******************************************************************************************
|
||
-- DS3 Test Far End Loopback Table
|
||
-- ******************************************************************************************
|
||
|
||
adGenDS3TestFarEndLoopbackTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF AdGenDS3TestFarEndLoopbackEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This table supports DS3 Test Far End Loopback parameters."
|
||
::= { adGenDS3TestFarEndLoopback 1 }
|
||
|
||
adGenDS3TestFarEndLoopbackEntry OBJECT-TYPE
|
||
SYNTAX AdGenDS3TestFarEndLoopbackEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An entry in the adGenDS3TestFarEndLoopbackTable."
|
||
INDEX { ifIndex }
|
||
::= { adGenDS3TestFarEndLoopbackTable 1 }
|
||
|
||
AdGenDS3TestFarEndLoopbackEntry ::=
|
||
SEQUENCE
|
||
{
|
||
adGenDS3TestFarEndLpbkType INTEGER,
|
||
adGenDS3TestFarEndFEACRequest INTEGER
|
||
}
|
||
|
||
adGenDS3TestFarEndLpbkType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(1),
|
||
line(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"- This object selects the far end loopback that will be executed upon recognition of
|
||
the adGenDS3TestFarEndStart object.
|
||
- This object should be ignored if issued while any test is in progress.
|
||
- none - indicates that no DS3 Line Loopback request will be issued via FEAC upon
|
||
recognition of the adGenDS3TestFarEndStart object.
|
||
- line <20> indicates that DS3 Line Loopback request will be issued via FEAC upon
|
||
recognition of the adGenDS3TestFarEndStart object."
|
||
::= { adGenDS3TestFarEndLoopbackEntry 1 }
|
||
|
||
adGenDS3TestFarEndFEACRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enable/Disable the response to income FEAC Line Loopback request."
|
||
::= { adGenDS3TestFarEndLoopbackEntry 2 }
|
||
|
||
-- ******************************************************************************************
|
||
-- DS3 Test Pattern Table
|
||
-- ******************************************************************************************
|
||
|
||
adGenDS3TestPatternTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF AdGenDS3TestPatternEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This table supports DS3 Test Pattern parameters."
|
||
::= { adGenDS3TestPattern 1 }
|
||
|
||
adGenDS3TestPatternEntry OBJECT-TYPE
|
||
SYNTAX AdGenDS3TestPatternEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An entry in the adGenDS3TestPatternTable."
|
||
INDEX { ifIndex }
|
||
::= { adGenDS3TestPatternTable 1 }
|
||
|
||
AdGenDS3TestPatternEntry ::=
|
||
SEQUENCE
|
||
{
|
||
adGenDS3TestPatternType INTEGER,
|
||
adGenDS3TestPatternSync INTEGER,
|
||
adGenDS3TestPatternErrorsRcvd Gauge32,
|
||
adGenDS3TestPatternInsertError INTEGER,
|
||
adGenDS3TestPatternResetCount INTEGER
|
||
}
|
||
|
||
adGenDS3TestPatternType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
patt2to23(1),
|
||
patt2to20(2),
|
||
patt2to15(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" This object selects the DS3 BERT that will be generated and detected upon
|
||
recognition of a start command.
|
||
patt2to23 <20> XNOR of 18th and 23rd stage outputs feed back into 1st stage input.
|
||
patt2to20 - XOR of 17th and 20th stage outputs feed back into 1st stage input.
|
||
patt2to15 <20> XNOR of 14th and 15th stage outputs feed back into 1st stage input."
|
||
::= { adGenDS3TestPatternEntry 1 }
|
||
|
||
|
||
adGenDS3TestPatternSync OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
true(1),
|
||
false(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" true <20> pattern test is in progress and incoming test pattern is in sync;
|
||
pattern test ended while incoming test pattern was in sync.
|
||
false <20> pattern test is in progress and incoming test pattern is out of sync;
|
||
pattern test ended while incoming test pattern was out of sync;
|
||
default if no test has ever been run."
|
||
::= { adGenDS3TestPatternEntry 2 }
|
||
|
||
adGenDS3TestPatternErrorsRcvd OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 <20> initialization value when pattern test starts.
|
||
>0 <20> increments for each logic error that occurs when pattern test is in
|
||
progress AND while incoming test pattern is in sync;
|
||
maintains value when pattern test ends."
|
||
::= { adGenDS3TestPatternEntry 3 }
|
||
|
||
adGenDS3TestPatternInsertError OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
insert(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"- Upon each reception of this object, 1 logic error is injected into DS3 payload
|
||
if a pattern test is in progress.
|
||
- The logic error is injected PRIOR to parity calculation."
|
||
::= { adGenDS3TestPatternEntry 4 }
|
||
|
||
adGenDS3TestPatternResetCount OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
reset(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"- Upon each reception of this object, the pattern error counter is reset to 0 if a
|
||
far end pattern test is in progress."
|
||
::= { adGenDS3TestPatternEntry 5 }
|
||
|
||
-- ******************************************************************************************
|
||
-- MIB Groups
|
||
-- ******************************************************************************************
|
||
adGenDS3TestGroup OBJECT-GROUP
|
||
OBJECTS
|
||
{
|
||
adGenDS3TestTimeout,
|
||
adGenDS3TestStartStop,
|
||
adGenDS3TestStatus,
|
||
adGenDS3TestTimeRemaining,
|
||
adGenDS3TestTimeElapsed,
|
||
adGenDS3TestNearEndLoopbackType,
|
||
adGenDS3TestFarEndLpbkType,
|
||
adGenDS3TestPatternType,
|
||
adGenDS3TestPatternSync,
|
||
adGenDS3TestPatternErrorsRcvd,
|
||
adGenDS3TestPatternInsertError,
|
||
adGenDS3TestPatternResetCount
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"These objects provide support for DS3 test procedures."
|
||
::= { adGenDS3TestMibGroups 1 }
|
||
|
||
|
||
END
|