adGenAOSPoEStatusInfo MODULE-IDENTITY
LAST-UPDATED "201807150000Z" -- July 15, 2018 / YYYYMMDDHHMMZ
ORGANIZATION "ADTRAN, Inc."
CONTACT-INFO
"Technical Support Dept.
Postal: ADTRAN, Inc.
901 Explorer Blvd.
Huntsville, AL 35806
Tel: +1 800 726-8663
Fax: +1 256 963 6217
E-mail: support@adtran.com"
DESCRIPTION
"This MIB is used to manage Power Over Ethernet information."
REVISION "201807150000Z" -- July 15, 2018 / YYYYMMDDHHMMZ
DESCRIPTION
"First Draft of ADTRAN-AOS-POE-STATS MIB module."
::= { adIdentity 10000 53 4 2 }
adGenAOSPoEMon OBJECT IDENTIFIER ::= { adGenAOSSwitch 3 }
adGenAOSPoESysInfo OBJECT IDENTIFIER ::= { adGenAOSPoEMon 1 }
adGenAOSPoEPortInfo OBJECT IDENTIFIER ::= { adGenAOSPoEMon 2 }
-- ========================================================================
adGenAOSPoEPseTotalPower OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
UNITS "Watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total power of the power source ethernet(PSE) device and expressed in Watts."
::= { adGenAOSPoESysInfo 1 }
adGenAOSPoEPseTotalPowerUsed OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
UNITS "Watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total power used of the power source ethernet(PSE) device and expressed in Watts."
::= { adGenAOSPoESysInfo 2 }
adGenAOSPoEPseTotalPowerAvailable OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
UNITS "Watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total power available of the power source ethernet(PSE) device and expressed in Watts."
::= { adGenAOSPoESysInfo 3 }
adGenAOSPoEPseAverageTotalPowerUsed OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
UNITS "Watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average total power used of the power source ethernet(PSE) device and expressed in Watts."
::= { adGenAOSPoESysInfo 4 }
adGenAOSPoEPortInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenAOSPoEPortInfoTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of objects that display and control the power
characteristics of power Ethernet ports on a Power Source
Entity (PSE) device. This group will be implemented in
managed power Ethernet switches and mid-span devices.
Values of all read-only objects in this table."
::= { adGenAOSPoEPortInfo 1 }
adGenAOSPoEPortInfoTableEntry OBJECT-TYPE
SYNTAX AdGenAOSPoEPortInfoTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of objects that display the power
characteristics of power Ethernet ports on a Power Source
Entity (PSE) device."
INDEX { ifIndex}
::= { adGenAOSPoEPortInfoTable 1 }
AdGenAOSPoEPortInfoTableEntry ::= SEQUENCE {
adGenAOSPoEPsePortIfName
DisplayString,
adGenAOSPoEPsePortPowerAdminMode
DisplayString,
adGenAOSPoEPsePortPowerStatusMode
INTEGER,
adGenAOSPoEPsePortPowerUsed
DisplayString,
adGenAOSPoEPsePortPowerClassifications
INTEGER,
adGenAOSPoEPsePortVoltage
DisplayString,
adGenAOSPoEPsePortCurrent
DisplayString,
adGenAOSPoEPsePortMaxPower
DisplayString,
adGenAOSPoEPsePortAveragePower
DisplayString
}
adGenAOSPoEPsePortIfName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing information about the
interface. This string should include the name of the
manufacturer, the product name and the version of the
interface hardware/software."
::= { adGenAOSPoEPortInfoTableEntry 1 }
adGenAOSPoEPsePortPowerAdminMode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An interface which can provide the PSE functions like,
auto,
legacy,
2-point,
4-point,
force-power,
and
off
"
::= { adGenAOSPoEPortInfoTableEntry 2 }
adGenAOSPoEPsePortPowerStatusMode OBJECT-TYPE
SYNTAX INTEGER {
limited(1),
delivering(2),
searching(3),
fault(4),
denied(5),
disabledThermal(6),
disabled(7),
otherFault(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describes the operational status of the port PD detection.
limited(1)- indicates that the PSE State diagram
is in the state Limited.
delivering(2) - indicates that the PSE State
diagram is in the state POWER_ON for a duration greater than
tlim max (see IEEE Std 802.3af Table 33-5 tlim)
searching(3)- indicates the PSE State diagram is in a state other than those listed above.
fault(4) - indicates that the PSE State diagram is in the state TEST_ERROR.
denied(5) - indicates that the PSE State diagram is in the state Denied.
disabledThermal(6) - indicates that the PSE State
diagram is in the state IDLE due to the variable
error_conditions.
disabled(7)- indicates that the PSE State diagram
is in the state DISABLED
otherFault(8)- indicates that the PSE State diagram
in the IDLE state due to the variable error_conditions.
Note: 'Limited' status is only valid for PoE+ devices that negotiate power using LLDP.
"
::= { adGenAOSPoEPortInfoTableEntry 3 }
adGenAOSPoEPsePortPowerUsed OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
UNITS "Watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port power usage in watts of a power source ethernet(PSE) device."
::= { adGenAOSPoEPortInfoTableEntry 4 }
adGenAOSPoEPsePortPowerClassifications OBJECT-TYPE
SYNTAX INTEGER {
class0(1),
class1(2),
class2(3),
class3(4),
class4(5),
notApplicable(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Classification is a way to tag different terminals on the
Power over LAN network according to their power consumption.
Devices such as IP telephones, WLAN access points and others, will be classified
according to their power requirements.
The meaning of the classification labels is defined in the
IEEE specification.
This variable is valid only while a PD is being powered,
that is, while the attribute adGenAOSPoEPsePortPowerStatusMode
is reporting delivering."
REFERENCE
"IEEE Std 802.3af Section 30.9.1.1.6 aPSEPowerClassification"
::= { adGenAOSPoEPortInfoTableEntry 5 }
adGenAOSPoEPsePortVoltage OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
UNITS "Volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port power in volts of a power source ethernet(PSE) device."
::= { adGenAOSPoEPortInfoTableEntry 6 }
adGenAOSPoEPsePortCurrent OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port current power in milliamps of a power source ethernet(PSE) device."
::= { adGenAOSPoEPortInfoTableEntry 7 }
adGenAOSPoEPsePortMaxPower OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
UNITS "Watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port maximum power in watts of a power source ethernet(PSE) device."
::= { adGenAOSPoEPortInfoTableEntry 8 }
adGenAOSPoEPsePortAveragePower OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
UNITS "Watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port average power usage in watts of a power source ethernet(PSE) device."
::= { adGenAOSPoEPortInfoTableEntry 9 }
-- Conformance information
adGenAOSPowerOverEthernetConformance OBJECT IDENTIFIER ::= { adGenAOSConformance 35 }
adGenAOSPowerOverEthernetGroups OBJECT IDENTIFIER ::= { adGenAOSPowerOverEthernetConformance 1 }
adGenAOSPowerOverEthernetCompliances OBJECT IDENTIFIER ::= { adGenAOSPowerOverEthernetConformance 2 }
-- Compliance Statements
adGenAOSPowerOverEthernetFullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMP entities which implement
version 2 of the adGenAOSPoEStatusInfo MIB. When this MIB
is fully implemented, then such an implementation can claim
full compliance."
MODULE
MANDATORY-GROUPS {
adGenAOSPoESysInfoGroup,
adGenAOSPoEPortInfoGroup
}
::= { adGenAOSPowerOverEthernetCompliances 1 }
-- Units of conformance
--
adGenAOSPoESysInfoGroup OBJECT-GROUP
OBJECTS {
adGenAOSPoEPseTotalPower,
adGenAOSPoEPseTotalPowerUsed,
adGenAOSPoEPseTotalPowerAvailable,
adGenAOSPoEPseAverageTotalPowerUsed
}
STATUS current
DESCRIPTION
"The PoE Port System Info Group."
::= { adGenAOSPowerOverEthernetGroups 1 }
adGenAOSPoEPortInfoGroup OBJECT-GROUP
OBJECTS {
adGenAOSPoEPsePortIfName,
adGenAOSPoEPsePortPowerAdminMode,
adGenAOSPoEPsePortPowerStatusMode,
adGenAOSPoEPsePortPowerUsed,
adGenAOSPoEPsePortPowerClassifications,
adGenAOSPoEPsePortVoltage,
adGenAOSPoEPsePortCurrent,
adGenAOSPoEPsePortMaxPower,
adGenAOSPoEPsePortAveragePower
}
STATUS current
DESCRIPTION
"The PoE Port Info Group."
::= { adGenAOSPowerOverEthernetGroups 2 }