--Acksys enterprise MIB V2.22.0
-- This MIB is compatible with SNMP V2c
-- Clean with VIM command: :g/@[GS]ET/d
ACKSYS-WLG-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises,mgmt, IpAddress, Counter32, Gauge32,
TimeTicks
FROM SNMPv2-SMI
OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI;
--Module Identity
acksysMIB MODULE-IDENTITY
LAST-UPDATED "201601291500Z"
ORGANIZATION "ACKSYS Communication & Systems"
CONTACT-INFO "support@acksys.fr"
DESCRIPTION "SNMPv2C Module for ACKSYS Solutions"
::= { acksys 2 }
-- textual conventions
DisplayString ::=
OCTET STRING
-- This data type is used to model textual information taken
-- from the NVT ASCII character set. By convention, objects
-- with this syntax are declared as having
--
-- SIZE (0..255)
PhysAddress ::=
OCTET STRING(SIZE (6))
-- This data type is used to model media addresses. For many
-- types of media, this will be in a binary representation.
-- For example, an ethernet address would be represented as
-- a string of 6 octets.
acksys OBJECT IDENTIFIER ::= { enterprises 28097 }
-- Acksys specific MIBs.
network-product OBJECT IDENTIFIER ::= { acksys 1 }
c-key-management OBJECT IDENTIFIER ::= { acksys 4 }
alarmSettings OBJECT IDENTIFIER ::= { acksys 5 }
powerStatus OBJECT IDENTIFIER ::= { acksys 6 }
wifiInterface OBJECT IDENTIFIER ::= { network-product 1 }
administration OBJECT IDENTIFIER ::= { network-product 2 }
os-stat OBJECT IDENTIFIER ::= { network-product 3 }
productSpecific OBJECT IDENTIFIER ::= { network-product 4 }
lanInterface OBJECT IDENTIFIER ::= {network-product 5}
settings OBJECT IDENTIFIER ::= { wifiInterface 1 }
bridge-mode OBJECT IDENTIFIER ::= { wifiInterface 2 }
access-point-mode OBJECT IDENTIFIER ::= { wifiInterface 3}
advancedSettings OBJECT IDENTIFIER ::= { wifiInterface 4 }
bridgeAPFiltering OBJECT IDENTIFIER ::= { bridge-mode 8}
bridgeRoaming OBJECT IDENTIFIER ::= { bridge-mode 9}
bridgeWirelessScan OBJECT IDENTIFIER ::= { bridge-mode 11}
bridgeNAT OBJECT IDENTIFIER ::= { bridge-mode 12}
bridgeNatPortForwarding OBJECT IDENTIFIER ::= { bridgeNAT 11}
bridgeRoamingAdvanced OBJECT IDENTIFIER ::={bridgeRoaming 1}
apClientFiltering OBJECT IDENTIFIER ::= { access-point-mode 4}
securitySettings OBJECT IDENTIFIER ::= { settings 9 }
securityWEP OBJECT IDENTIFIER ::= { securitySettings 2 }
securityWPA-WPA2 OBJECT IDENTIFIER ::= { securitySettings 3}
securityPresharedKey OBJECT IDENTIFIER ::= { securityWPA-WPA2 1}
securityRadius OBJECT IDENTIFIER ::= { securityWPA-WPA2 2} --Obsolete
securityBackupRadius OBJECT IDENTIFIER ::= { securityWPA-WPA2 3} --Obsolete
securityRadiusAP OBJECT IDENTIFIER ::= { securityRadius 6}
securityRadiusBridge OBJECT IDENTIFIER ::= { securityRadius 7}
securityRadiusAPBackup OBJECT IDENTIFIER ::= { securityRadiusAP 6}
wds OBJECT IDENTIFIER ::= { access-point-mode 5}
lanTimeOutSettings OBJECT IDENTIFIER ::= { access-point-mode 8}
longDistanceSettings OBJECT IDENTIFIER ::= { advancedSettings 1}
wlg-aboard OBJECT IDENTIFIER ::= { productSpecific 1 }
alarmSettingsPower1Down OBJECT IDENTIFIER ::= { alarmSettings 2 }
alarmSettingsPower2Down OBJECT IDENTIFIER ::= { alarmSettings 3 }
alarmSettingsLan1Down OBJECT IDENTIFIER ::= { alarmSettings 4 }
alarmSettingsLan2Down OBJECT IDENTIFIER ::= { alarmSettings 5 }
alarmSettingsLan3Down OBJECT IDENTIFIER ::= { alarmSettings 6 }
alarmSettingsLan4Down OBJECT IDENTIFIER ::= { alarmSettings 7 }
alarmSettingsLan5Down OBJECT IDENTIFIER ::= { alarmSettings 8 }
alarmSettingsLan6Down OBJECT IDENTIFIER ::= { alarmSettings 9 }
alarmSettingsLan7Down OBJECT IDENTIFIER ::= { alarmSettings 10 }
alarmSettingsLan8Down OBJECT IDENTIFIER ::= { alarmSettings 11 }
alarmSettingsWLANDown OBJECT IDENTIFIER ::= { alarmSettings 12 }
--acksys group
acksysProductID OBJECT-TYPE
SYNTAX INTEGER {
wlg-link(1),
wlg-aboard-n(2),
wlg-link-v2(3),
wlg-aboard-n-v2(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Return the product Id code
"
::= { acksys 3 }
--network-product
--Wireless Interface group
settingInterfaceSsid OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..33))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SSID (wireless network name)
"
::= { settings 1 }
settingInterfaceWifiMode OBJECT-TYPE
SYNTAX INTEGER {
bridge(1),
access-point(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select between MAX-ACCESS POINT and BRIDGE
"
::= { settings 2 }
settingInterfaceChannel OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A wireless network uses specific channels to handle communication between clients. Some channels in your area may have interference from other electronic devices. Choose the clearest channel to help optimize the performance and coverage of your wireless network.(used in MAX-ACCESS POINT & AD-HOC BRIDGE modes)
"
::= { settings 3 }
settingInterface80211Mode OBJECT-TYPE
SYNTAX INTEGER {
b-only(1),
g-only(2),
mixed-b-g(3),
a-only(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select IEEE 802.11x compatibility mode.
"
::= { settings 4 }
settingInterfaceSuper-a-g-Mode OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
super-g-without-turbo(2),
super-g-with-static-turbo(3),
super-g-with-dynamic-turbo(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter enables the SUPER A/G mode to reach the 108 Mbits/s speed
"
::= { settings 5 }
settingEnableRadio OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Enable / Disable wifi radio
"
::= { settings 6 }
settingTxPoxer OBJECT-TYPE
SYNTAX INTEGER {
high(1),
medium(2),
low(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Set WIFI tx power
"
::= { settings 7 }
settingRegion OBJECT-TYPE
SYNTAX INTEGER {
israel(2),
usa(4),
hong-kong(5),
canada(6),
australia(7),
franceoutdoor(10),
europe(14),
japan(17),
singapore(18),
korea(20),
mexico(21),
indonesia(22),
china(23),
russia(27),
brazil(28),
chile(29),
thailand(30),
peru(31)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Set WIFI regulation domain
"
::= { settings 8 }
settingAntennaChoice OBJECT-TYPE
SYNTAX INTEGER {
diversity(1),
main(2),
aux(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Set the antenna type
"
::= { settings 10 }
--Setting Transmission rate
settingTransmisionRate OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Set the transmission rate in Mbps
Automatic : -1
With SuperAG Mode : 108,96,72,48,36,24,18,12
Without SuperAG mode : 54,48,36,24,18,12,9,6
802.11b mode : 11,5.5,2,1
"
::= { settings 11 }
--Setting flag udap sans password
settingFlagUdapnopassword OBJECT-TYPE
SYNTAX INTEGER {
false(1),
true(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure LAN settings without password
"
::= { settings 12 }
--Setting filter in same net
settingFlagFiltersamenet OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
different-subnet-filter(2),
custom-subnet-filter(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Subnet filter settings:
(1) Disable the filter,
(2) Different subnet filter: drop all packets on the different subnet,
(3) Custom subnet filter: drop all packets on the custom subnet (You need to define IP and subnet mask of custom subnet.)
"
::= { settings 13 }
--Setting economy filter
settingFlagFilterframecosom OBJECT-TYPE
SYNTAX INTEGER {
false(1),
true(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting economy filter
"
::= { settings 14 }
--Setting DFS support
settingDFSsupport OBJECT-TYPE
SYNTAX INTEGER {
false(1),
true(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting DFS support
"
::= { settings 15 }
settingFilterCustomIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Set IP address of custom subnet.
When settingFlagFiltersamenet is set on '(3) Custom subnet filter', you need to define custom subnet.
All packets on the custom subnet will be dropped.
"
::= { settings 16 }
settingFilterCustomSubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set subnet mask of custom subnet.
When settingFlagFiltersamenet is set on '(3) Custom subnet filter', you need to define custom subnet.
All packets on the custom subnet will be dropped.
"
::= { settings 17 }
-- Advanced setting group
enable802-11d OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Enable / disable the 802.11d.
"
::= { advancedSettings 2 }
enableIsolateSTA OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Enable / disable the isolating access point.
"
::= { advancedSettings 3 }
-- long distance settings groups
enableLongDistance OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Enable / disable distance parameter.
"
::= { longDistanceSettings 1 }
distanceAntennaMeter OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Set the distance between antenna in meter.
"
::= { longDistanceSettings 2 }
distanceSlotTime OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { longDistanceSettings 3 }
distanceAckTimeout OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { longDistanceSettings 4 }
distanceCtsTimeout OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { longDistanceSettings 5 }
--Setting security group
securityMode OBJECT-TYPE
SYNTAX INTEGER {
none(1),
wep(2),
wpa-wpa2-psk(3),
wpa-wpa2(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Set the security mode
"
::= { securitySettings 1 }
--WEP group
securityModeWepKeyLen OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the WEP key len (64 bits or 128 bits)
"
::= { securityWEP 1 }
securityModeWepKey-1 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..26))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"WEP key 1 in hexadecimal format
"
::= { securityWEP 2 }
securityModeWepKey-2 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..26))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"WEP key 2 in hexadecimal format
"
::= { securityWEP 3 }
securityModeWepKey-3 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..26))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"WEP key 3 in hexadecimal format
"
::= { securityWEP 4 }
securityModeWepKey-4 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..26))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"WEP key 4 in hexadecimal format
"
::= { securityWEP 5 }
securityModeDefaultWepKey OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the wep key used
"
::= { securityWEP 6 }
securityModeWepAuthentication OBJECT-TYPE
SYNTAX INTEGER {
open(1),
shared(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set WEP Authentication
"
::= { securityWEP 7 }
--WPA/WPA2-PSK group
securityModeWpaMode OBJECT-TYPE
SYNTAX INTEGER {
wpa(1),
wpa2(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select the wpa mode
"
::= { securityWPA-WPA2 4 }
securityModeWpaCipherType OBJECT-TYPE
SYNTAX INTEGER {
tkip(1),
aes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"select the cipher type
"
::= { securityWPA-WPA2 5 }
securityModeWpaKeyUpdateInterval OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the group key interval
"
::= { securityWPA-WPA2 6 }
--Pre-shared key group
securityModeWpaPresharedKey OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (8..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the group key interval
"
::= { securityPresharedKey 1 }
-- radius AP
securityModeWPARadiusAPAuthenticationTimeout OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the group key interval
"
::= { securityRadiusAP 1 }
securityModeWPARadiusAPIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the group key interval
"
::= { securityRadiusAP 2 }
securityModeWPARadiusAPPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the group key interval
"
::= { securityRadiusAP 3 }
securityModeWPARadiusAPSecret OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the group key interval
"
::= { securityRadiusAP 4 }
securityModeWPARadiusAPMacAddressAuthentication OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the group key interval
"
::= { securityRadiusAP 5 }
--Obsolete OIDs
securityModeWPARadiusAuthenticationTimeout OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Set the group key interval
"
::= { securityRadius 1 }
securityModeWPARadiusIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Set the group key interval
"
::= { securityRadius 2 }
securityModeWPARadiusPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Set the group key interval
"
::= { securityRadius 3 }
securityModeWPARadiusSecret OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..64))
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Set the group key interval
"
::= { securityRadius 4 }
securityModeWPARadiusMacAddressAuthentication OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Set the group key interval
"
::= { securityRadius 5 }
--End of Obsolete OIDs
-- backup radius
securityModeWPABackupRadiusAPIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the group key interval
"
::= { securityRadiusAPBackup 1 }
securityModeWPARadiusBackupAPPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the group key interval
"
::= { securityRadiusAPBackup 2 }
securityModeWPARadiusBackupAPSecret OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the group key interval
"
::= { securityRadiusAPBackup 3 }
securityModeWPABackupRadiusAPMacAddressAuthentication OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the group key interval
"
::= { securityRadiusAPBackup 4 }
--Obsolete OIDs
securityModeWPABackupRadiusIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Set the group key interval
"
::= { securityBackupRadius 1 }
securityModeWPARadiusBackupPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Set the group key interval
"
::= { securityBackupRadius 2 }
securityModeWPARadiusBackupSecret OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..64))
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Set the group key interval
"
::= { securityBackupRadius 3 }
securityModeWPABackupRadiusMacAddressAuthentication OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Set the group key interval
"
::= { securityBackupRadius 4 }
--End of Obsolete OIDs
-- radius Bridge
securityModeWPARadiusLogin OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the group key interval
"
::= { securityRadiusBridge 1 }
securityModeWPARadiusPassword OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the group key interval
"
::= { securityRadiusBridge 2 }
--Access point group
apClientTable OBJECT-TYPE
SYNTAX SEQUENCE OF ApClientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Significant only in MAX-ACCESS POINT mode. This table shows information about connected clients."
::= { access-point-mode 1 }
apAutomaticChannel OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Enable / disable the automatic channel select
"
::= { access-point-mode 2}
apClientCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" count the number of entries in ApClientEntry
"
::= { access-point-mode 3}
apClientEntry OBJECT-TYPE
SYNTAX ApClientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Shows information about the connected client.
"
INDEX { clientMacAddr }
::= { apClientTable 1 }
ApClientEntry ::=
SEQUENCE {
clientMacAddr
PhysAddress,
client80211Mode
INTEGER,
clientTxRate
INTEGER ,
clientRssiPercent
Gauge32
}
clientMacAddr OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address of the client connected to the MAX-ACCESS POINT."
::= { apClientEntry 1 }
client80211Mode OBJECT-TYPE
SYNTAX INTEGER {
b-only(1),
g-only(2),
mixed-b-g(3),
a-only(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Show client's IEEE 802.11x compatibility mode."
::= { apClientEntry 2 }
clientTxRate OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Client's communication speed in bits per second"
::= { apClientEntry 3 }
clientRssiPercent OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Client's RSSI (percent)"
::= { apClientEntry 4}
settingSSIDVisibility OBJECT-TYPE
SYNTAX INTEGER {
visible(2),
invisible(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Enable or Disable SSID Visibility
"
::= { access-point-mode 6}
enableSTP OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Enable / disable STP protocol.
"
::= { access-point-mode 7 }
enableLanTimeout OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Enable / disable LAN timeout.
ACCESS POINT can be configured to auto-disconnect the radio when the LAN is disconnected from the equipment.
"
::= { lanTimeOutSettings 1 }
lanTimeoutIPSurvey OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Define the IP address where the probe was be sent.
"
::= { lanTimeOutSettings 2 }
lanTimeoutMaxProbe OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Define the number of probe without response necessairy to disconnect the radio.
"
::= { lanTimeOutSettings 3 }
lanTimeoutProbeTimeout OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Define the probe response waiting time in seconds.
"
::= { lanTimeOutSettings 4 }
lanTimeoutProbeInterval OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Define the times in seconds between each probes.
"
::= { lanTimeOutSettings 5 }
------------------------
--AP Filtering
apClientFilteringEnable OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable / Disable Client Filtering.
"
::= { apClientFiltering 1 }
apClientFilteringMode OBJECT-TYPE
SYNTAX INTEGER {
allow(1),
deny(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Select Client Filtering Mode (allow/Deny)
"
::= { apClientFiltering 2 }
apClientWirelessFiltering OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable or disable Wireless client filtering
"
::= { apClientFiltering 3 }
apClientWiredFiltering OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable or disable Wireless client filtering
"
::= { apClientFiltering 4 }
apClientFilteringMACAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "
MAC address field
"
::= { apClientFiltering 5 }
apClientFilteringName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name Field
"
::= { apClientFiltering 6}
apClientFilteringSave OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "write 1 to save the rule
"
::= { apClientFiltering 7 }
apClientFilteringDelete OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "when writed, delete the rule which is
indexed by the written value
"
::= { apClientFiltering 8 }
apClientFilteringEnableRule OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "when writed, enable the rule which is
indexed by the written value
"
::= { apClientFiltering 9 }
apClientFilteringDisableRule OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "when writed, disable the rule which is
indexed by the written value
"
::= { apClientFiltering 10 }
apClientFilteringTable OBJECT-TYPE
SYNTAX SEQUENCE OF ApClientFilteringEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Significant only in MAX-ACCESS POINT mode. This table shows information AP bridge filtering rules list."
::= { apClientFiltering 11 }
apClientFilteringEntry OBJECT-TYPE
SYNTAX ApClientFilteringEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Shows information of the rule.
"
INDEX { apClientFilteringListId }
::= { apClientFilteringTable 1 }
ApClientFilteringEntry ::=
SEQUENCE {
apClientFilteringListId
INTEGER,
apClientFilteringListName
OCTET STRING,
apClientFilteringListMAC
PhysAddress,
apClientFilteringListEnable
INTEGER
}
apClientFilteringListId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rule index."
::= { apClientFilteringEntry 1 }
apClientFilteringListMAC OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address of the client."
::= { apClientFilteringEntry 3 }
apClientFilteringListName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Show rule's name"
::= { apClientFilteringEntry 2 }
apClientFilteringListEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Show if the rule is enabled or not"
::= { apClientFilteringEntry 4 }
--End AP Filtering
------------------------
------------------------
--WDS
apWDSEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable or Disable WDS.
"
::= { wds 1 }
apWDSEnableSTP OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable or Disable STP when WDS is on
"
::= { wds 2 }
apWDSMAC1 OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "
First AP mac address
"
::= { wds 3 }
apWDSMAC2 OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "
Second AP mac address
"
::= { wds 4 }
apWDSMAC3 OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "
Third AP mac address
"
::= { wds 5 }
apWDSMAC4 OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "
fourth AP mac address
"
::= { wds 6 }
apWDSMAC5 OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "
fith AP mac address
"
::= { wds 7 }
apWDSMAC6 OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "
sixth AP mac address
"
::= { wds 8 }
--bridge group
bridge-modeLinkStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1), -- ready to pass packets
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "MAX-ACCESS POINT's connection status.
"
::= { bridge-mode 1 }
bridge-modeMacAP OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
MAX-ACCESS POINT's MAC ADDRESS we are connected with.
"
::= { bridge-mode 2 }
bridge-modeRSSI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
MAX-ACCESS POINT's connection RSSI.
"
::= { bridge-mode 3 }
bridge-modeRSSIdBm OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
Connection's RSSI in dBm.
"
::= { bridge-mode 4 }
bridge-modeRSSIPercent OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
Connection's RSSI in percent.
"
::= { bridge-mode 5}
bridge-modeCurrentTxRate OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
Current communication speed in bits per second.
"
::= { bridge-mode 6}
bridge-WirelessMode OBJECT-TYPE
SYNTAX INTEGER {
infrastructure(1),
ad-hoc(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Select the Wireless mode. Infrastructure mode require an access point.
"
::= { bridge-mode 7}
--*********************
--********************
-- bridge
bridgeAPFilteringEnable OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable or Disable AP Filtering.
"
::= { bridgeAPFiltering 1 }
bridgeAPFilteringMode OBJECT-TYPE
SYNTAX INTEGER {
allow(1),
deny(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Select AP Filtering Mode (allow/Deny)
"
::= { bridgeAPFiltering 2 }
bridgeAPFilteringMACAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "
MAC address field
"
::= { bridgeAPFiltering 3 }
bridgeAPFilteringName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name Field
"
::= { bridgeAPFiltering 4 }
bridgeAPFilteringSave OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "write 1 to save the rule
"
::= { bridgeAPFiltering 5 }
bridgeAPFilteringDelete OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "when writed, delete the rule which is
indexed by the written value
"
::= { bridgeAPFiltering 6 }
bridgeAPFilteringEnableRule OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "when writed, enable the rule which is
indexed by the written value
"
::= { bridgeAPFiltering 7 }
bridgeAPFilteringDisableRule OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "when writed, disable the rule which is
indexed by the written value
"
::= { bridgeAPFiltering 8 }
bridgeAPFilteringTable OBJECT-TYPE
SYNTAX SEQUENCE OF BridgeAPFilteringEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Significant only in MAX-ACCESS POINT mode. This table shows information bridge AP filtering rules list."
::= { bridgeAPFiltering 9 }
bridgeAPFilteringEntry OBJECT-TYPE
SYNTAX BridgeAPFilteringEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Shows information of the rule.
"
INDEX { bridgeAPFilteringListId }
::= { bridgeAPFilteringTable 1 }
BridgeAPFilteringEntry ::=
SEQUENCE {
bridgeAPFilteringListId
INTEGER,
bridgeAPFilteringListName
OCTET STRING,
bridgeAPFilteringListMAC
PhysAddress,
bridgeAPFilteringListEnable
INTEGER
}
bridgeAPFilteringListId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rule index."
::= { bridgeAPFilteringEntry 1 }
bridgeAPFilteringListMAC OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address of the client."
::= { bridgeAPFilteringEntry 3 }
bridgeAPFilteringListName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Show rule's name"
::= { bridgeAPFilteringEntry 2 }
bridgeAPFilteringListEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Show if a rule is enabled or not.
"
::= { bridgeAPFilteringEntry 4 }
bridgeChannelList OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..40))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A wireless network uses specific channels in the 2.4GHz or 5GHz wireless spectrum to handle communication between clients. Some channels in your area may have interference from other electronic devices. Your wireless bridge will use the channel that is used by the access point it will associate with. But you can select here your channel preference to help optimize the performance and coverage of your wireless network. If you used the roaming, Acksys recommend to used only one channel for better bandwith.
"
::= { bridge-mode 10 }
--roaming setting
bridgeRoamingEnable OBJECT-TYPE
SYNTAX INTEGER{
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Roaming enables WiFi clients to roam among AP when WiFi RSSI of the current AP becomes weak. This radio button enables/disables the roaming capabilities of the bridge.
"
::={bridgeRoaming 2}
bridgeRoamingRSSIThreshold-dBm OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Allows to configure the RSSI roaming threshold (in dBm, or percent) from which the roaming algorithm (to find a better AP) will start. AP changing will only be effective if the current RSSI is lower than that threshold, and if a new AP with a better RSSI has been detected.
"
::= {bridgeRoaming 3}
bridgeRoamingRSSIThreshold-percent OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Allows to configure the RSSI roaming threshold (in dBm, or percent) from which the roaming algorithm (to find a better AP) will start. AP changing will only be effective if the current RSSI is lower than that threshold, and if a new AP with a better RSSI has been detected.
"
::= {bridgeRoaming 4}
bridgeRoamingAdvancedScanThreshold-dbm OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Allows to configure the RSSI scan threshold (in dBm, or in percent) from which the access point active scan will start. The access point active scan process looking on each valid channel the access point where it will be possible to roam.
"
::= {bridgeRoamingAdvanced 1}
bridgeRoamingAdvancedScanThreshold-percent OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Allows to configure the RSSI scan threshold (in dBm, or in percent) from which the access point active scan will start. The access point active scan process looking on each valid channel the access point where it will be possible to roam.
"
::= {bridgeRoamingAdvanced 2}
bridgeRoamingAdvancedScanPeriod OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Allow to configure the time between two scan.
Reduce this time increase the Access Point discover, but decrease the bandwith if you used more one channel.
"
::= {bridgeRoamingAdvanced 3}
bridgeRoamingAdvancedScanDuration OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Allow to configure the duration while the bridge waiting the Access Point answer.
Reduce this duration increase the Bandwith when you used more one channel, but decrase the Access Point discover.
"
::= {bridgeRoamingAdvanced 4}
bridgeRoamingAdvancedAPLossDetection OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "If nothing is received from the AP during a certain amount of time, it will be considered unreachable.
This amount of time is computed as:
'AP timeout' = 'AP loss detection' x 'beacon interval'.
The recommended value for 'AP loss detection' is 5.
The recommended value for 'Beacon interval' (which should be configured in your AP) is 50 ms.
If the AP timeout is set too low, it may decrease the bandwidth and roaming performance.
"
::= {bridgeRoamingAdvanced 5}
-- End bridge filter
--***********************
--Bridge status scan
bridgeWileressScanTable OBJECT-TYPE
SYNTAX SEQUENCE OF BridgeWirelessScanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Significant only in MAX-ACCESS POINT mode. This table shows information AP bridge filtering rules list."
::= { bridgeWirelessScan 1 }
bridgeWirelessScanEntry OBJECT-TYPE
SYNTAX BridgeWirelessScanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Shows information of the rule.
"
INDEX { apClientFilteringListId }
::= { bridgeWileressScanTable 1 }
BridgeWirelessScanEntry ::=
SEQUENCE {
bridgeWirelessScanAPMac
PhysAddress,
bridgeWirelessScanSSID
DisplayString,
bridgeWirelessScanChannel
INTEGER,
bridgeWirelessScanMode
INTEGER,
bridgeWirelessScanSecurity
INTEGER,
bridgeWirelessScanRssi
INTEGER
}
bridgeWirelessScanAPMac OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address of the access point."
::= { bridgeWirelessScanEntry 1 }
bridgeWirelessScanSSID OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..33))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { bridgeWirelessScanEntry 2 }
bridgeWirelessScanChannel OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { bridgeWirelessScanEntry 3 }
bridgeWirelessScanMode OBJECT-TYPE
SYNTAX INTEGER {
b-only(1),
g-only(2),
mixed-b-g(3),
a-only(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Show AP's IEEE 802.11x compatibility mode."
::= { bridgeWirelessScanEntry 4 }
bridgeWirelessScanSecurity OBJECT-TYPE
SYNTAX INTEGER {
none(0),
wep(1),
wpa(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { bridgeWirelessScanEntry 5 }
bridgeWirelessScanRssi OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { bridgeWirelessScanEntry 6 }
--end bridge status scan
--BrigeNAT
brigeNATStatus OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable / disable NAT
"
::= { bridgeNAT 1 }
brigeNATEnablePing OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable / disable ping response from WAN
"
::= { bridgeNAT 2 }
brigeNATEnableProductWebServer OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable / disable the internal web server from WAN
"
::= { bridgeNAT 3 }
brigeNATInternalWebServerPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TCP port used by internal web server from WAN
"
::= { bridgeNAT 4 }
brigeNATEnableProductSnmpServer OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable / disable the internal snmp server from WAN
"
::= { bridgeNAT 5 }
brigeNATInternalWebSnmpPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TCP port used by internal snmp server from WAN
"
::= { bridgeNAT 6 }
brigeNATWanIpAddrMode OBJECT-TYPE
SYNTAX INTEGER {static(1),dhcp(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ip address mode on wan side
"
::= { bridgeNAT 7 }
brigeNATWanIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Static Ip address on wan side
"
::= { bridgeNAT 8 }
brigeNATWanSubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Subnet mask on wan side
"
::= { bridgeNAT 9 }
brigeNATWanGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Gateway ip address on wan side
"
::= { bridgeNAT 10 }
bridgeNatPortForwardingName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Show rule's name
"
::= { bridgeNatPortForwarding 2 }
bridgeNatPortForwardingIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Show ipaddress to forward data
"
::= { bridgeNatPortForwarding 3 }
bridgeNatPortForwardingPublicTcpPort OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Show public TCP port
"
::= { bridgeNatPortForwarding 4 }
bridgeNatPortForwardingPrivateTcpPort OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Show private TCP port
"
::= { bridgeNatPortForwarding 5 }
bridgeNatPortForwardingPublicUdpPort OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Show public TCP port
"
::= { bridgeNatPortForwarding 6 }
bridgeNatPortForwardingPrivateUdpPort OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Show private TCP port
"
::= { bridgeNatPortForwarding 7 }
bridgeNatPortForwardingEnableRule OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"when writed, enable the rule which is
indexed by the written value
"
::= { bridgeNatPortForwarding 8 }
bridgeNatPortForwardingDisableRule OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"when writed, disable the rule which is
indexed by the written value
"
::= { bridgeNatPortForwarding 9 }
bridgeNatPortForwardingSaveRule OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"when writed, save the rule which is
indexed by the written value
"
::= { bridgeNatPortForwarding 10 }
bridgeNatPortForwardingDeleteRule OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"when writed, delete the rule which is
indexed by the written value
"
::= { bridgeNatPortForwarding 11 }
bridgeNatPortForwardingTable OBJECT-TYPE
SYNTAX SEQUENCE OF BridgeNatPortForwardingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
This table show information on port forwading rules
"
::= { bridgeNatPortForwarding 1 }
bridgeNatPortForwardingEntry OBJECT-TYPE
SYNTAX BridgeNatPortForwardingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"shows information of rule.
"
INDEX {bridgeNatPortForwardingListId}
::= {bridgeNatPortForwardingTable 1}
BridgeNatPortForwardingEntry ::=
SEQUENCE {
bridgeNatPortForwardingListId
INTEGER,
bridgeNatPortForwardingListEnable
INTEGER,
bridgeNatPortForwardingListName
OCTET STRING,
bridgeNatPortForwardingListIpAddr
IpAddress,
bridgeNatPortForwardingListPublicTcpPort
OCTET STRING,
bridgeNatPortForwardingListPrivateTcpPort
OCTET STRING,
bridgeNatPortForwardingListPublicUdpPort
OCTET STRING,
bridgeNatPortForwardingListPrivateUdpPort
OCTET STRING
}
bridgeNatPortForwardingListId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rule index"
::= { bridgeNatPortForwardingEntry 1 }
bridgeNatPortForwardingListName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Show rule's name"
::= { bridgeNatPortForwardingEntry 2 }
bridgeNatPortForwardingListIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Show ipaddress to forward data"
::= { bridgeNatPortForwardingEntry 3 }
bridgeNatPortForwardingListPublicTcpPort OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Show public TCP port"
::= { bridgeNatPortForwardingEntry 4 }
bridgeNatPortForwardingListPrivateTcpPort OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Show private TCP port"
::= { bridgeNatPortForwardingEntry 5 }
bridgeNatPortForwardingListPublicUdpPort OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Show public TCP port"
::= { bridgeNatPortForwardingEntry 6 }
bridgeNatPortForwardingListPrivateUdpPort OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Show private TCP port"
::= { bridgeNatPortForwardingEntry 7 }
bridgeNatPortForwardingListEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rule state"
::= { bridgeNatPortForwardingEntry 8 }
--end bridgeNAT
--*********************
-- Administration group
adminReset OBJECT-TYPE
SYNTAX INTEGER {reset(1)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "
Writing 1 resets the product. This must be done after each configuration change.
"
::= { administration 1}
adminResetFactory OBJECT-TYPE
SYNTAX INTEGER {resetfactory(1)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "
Writing 1 resets the product to the factory settings.
"
::= { administration 2}
adminEnableWebServer OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Enable or Disable internal webserver.
"
::= { administration 3}
adminAutoSave OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Enable or Disable the automatic change saving. When this function is disable, the modification is not save automaticaly after change and certainly OID is applied imediatly.
"
::= { administration 4}
adminSave OBJECT-TYPE
SYNTAX INTEGER {
saveNotRequire(3),
saveRequire(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Write 1 to save the modification in flash. Read this OID to know if a save is require.
"
::= { administration 5}
-- os-stat group
os-statFreeHeap OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The amount of memory currently available, measured in bytes.
"
::= { os-stat 1 }
os-statTotalHeap OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total size of the heap, measured in bytes.
"
::= { os-stat 2 }
os-statHeapLowWater OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low water mark for the heap. Writing any value this variable will always
reset the low water to the total heap size.
"
::= { os-stat 3 }
os-statNetpageFree OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The amount of netpages currently available, measured in bytes.
"
::= { os-stat 4 }
os-statNetpageLowWater OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low water mark for the netpage.
"
::= { os-stat 5 }
-- wlg-aboard group
wlg-aboard-PW1-state OBJECT-TYPE
SYNTAX INTEGER {powerOff(1), powerOn(2)}
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Power 1 state
"
::= { wlg-aboard 1 }
wlg-aboard-PW2-state OBJECT-TYPE
SYNTAX INTEGER {powerOff(1), powerOn(2)}
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Power 2 state
"
::= { wlg-aboard 2 }
-- lanInterface group
lanInterfaceIpAddrMode OBJECT-TYPE
SYNTAX INTEGER {static(1),dhcp(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Static or DHCP Ip settings
"
::= { lanInterface 1 }
lanInterfaceIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Product IP address
"
::= { lanInterface 2 }
lanInterfaceSubNetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Network mask
"
::= { lanInterface 3 }
lanInterfaceGatewayIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP gateway
"
::= { lanInterface 4 }
lanInterfaceHostName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Adresse IP de la gateway
"
::= { lanInterface 5 }
lanInterfaceLocalDomainName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..33))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Adresse IP de la gateway
"
::= { lanInterface 6 }
-- c-key-management
ckeyManagementCopySettingTo OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Write 1 to copy the current settings to the C-KEY. After this action, all previous data in the C-KEY are lost.
"
::= { c-key-management 1 }
ckeyManagementCopySettingFrom OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Write 1 to copy the product settings from the C-KEY. After this action, the product has C-KEY settings. Reboot your device to apply the new settings.
"
::= { c-key-management 2 }
-- alarmSettings
alarmSettingsTest OBJECT-TYPE
SYNTAX INTEGER {set(1),clear(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Allow to get and set the Alarm output status.
"
::= { alarmSettings 1 }
alarmSettingsPower1DownEnable OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { alarmSettingsPower1Down 1 }
alarmSettingsPower1DownEnableAutomaticReset OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { alarmSettingsPower1Down 2 }
alarmSettingsPower1DownStatus OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2),ack(3)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Read to know the alarm source status (disable / enable )
Write 3 to acknowledge the alarm source.
"
::= { alarmSettingsPower1Down 3 }
alarmSettingsPower2DownEnable OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { alarmSettingsPower2Down 1 }
alarmSettingsPower2DownEnableAutomaticReset OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { alarmSettingsPower2Down 2 }
alarmSettingsPower2DownStatus OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2),ack(3)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Read to know the alarm source status (disable / enable )
Write 3 to acknowledge the alarm source.
"
::= { alarmSettingsPower2Down 3 }
alarmSettingsLan1DownEnable OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { alarmSettingsLan1Down 1 }
alarmSettingsLan1DownEnableAutomaticReset OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { alarmSettingsLan1Down 2 }
alarmSettingsLan1DownStatus OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2),ack(3)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Read to know the alarm source status (disable / enable )
Write 3 to acknowledge the alarm source.
"
::= { alarmSettingsLan1Down 3 }
alarmSettingsLan2DownEnable OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { alarmSettingsLan2Down 1 }
alarmSettingsLan2DownEnableAutomaticReset OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { alarmSettingsLan2Down 2 }
alarmSettingsLan2DownStatus OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2),ack(3)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Read to know the alarm source status (disable / enable )
Write 3 to acknowledge the alarm source.
"
::= { alarmSettingsLan2Down 3 }
alarmSettingsLan3DownEnable OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { alarmSettingsLan3Down 1 }
alarmSettingsLan3DownEnableAutomaticReset OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { alarmSettingsLan3Down 2 }
alarmSettingsLan3DownStatus OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2),ack(3)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Read to know the alarm source status (disable / enable )
Write 3 to acknowledge the alarm source.
"
::= { alarmSettingsLan3Down 3 }
alarmSettingsLan4DownEnable OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { alarmSettingsLan4Down 1 }
alarmSettingsLan4DownEnableAutomaticReset OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { alarmSettingsLan4Down 2 }
alarmSettingsLan4DownStatus OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2),ack(3)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Read to know the alarm source status (disable / enable )
Write 3 to acknowledge the alarm source.
"
::= { alarmSettingsLan4Down 3 }
alarmSettingsLan5DownEnable OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { alarmSettingsLan5Down 1 }
alarmSettingsLan5DownEnableAutomaticReset OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { alarmSettingsLan5Down 2 }
alarmSettingsLan5DownStatus OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2),ack(3)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Read to know the alarm source status (disable / enable )
Write 3 to acknowledge the alarm source.
"
::= { alarmSettingsLan5Down 3 }
alarmSettingsLan6DownEnable OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { alarmSettingsLan6Down 1 }
alarmSettingsLan6DownEnableAutomaticReset OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { alarmSettingsLan6Down 2 }
alarmSettingsLan6DownStatus OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2),ack(3)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Read to know the alarm source status (disable / enable )
Write 3 to acknowledge the alarm source.
"
::= { alarmSettingsLan6Down 3 }
alarmSettingsLan7DownEnable OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { alarmSettingsLan7Down 1 }
alarmSettingsLan7DownEnableAutomaticReset OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { alarmSettingsLan7Down 2 }
alarmSettingsLan7DownStatus OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2),ack(3)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Read to know the alarm source status (disable / enable )
Write 3 to acknowledge the alarm source.
"
::= { alarmSettingsLan7Down 3}
alarmSettingsLan8DownEnable OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { alarmSettingsLan8Down 1 }
alarmSettingsLan8DownEnableAutomaticReset OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { alarmSettingsLan8Down 2 }
alarmSettingsLan8DownStatus OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2),ack(3)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Read to know the alarm source status (disable / enable )
Write 3 to acknowledge the alarm source.
"
::= { alarmSettingsLan8Down 3 }
alarmSettingsWLANDownEnable OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { alarmSettingsWLANDown 1 }
alarmSettingsWLANDownEnableAutomaticReset OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { alarmSettingsWLANDown 2 }
alarmSettingsWLANDownStatus OBJECT-TYPE
SYNTAX INTEGER {disable(1),enable(2),ack(3)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Read to know the alarm source status (disable / enable )
Write 3 to acknowledge the alarm source.
"
::= { alarmSettingsWLANDown 3 }
-- powerStatus
powerStatus-PW1-state OBJECT-TYPE
SYNTAX INTEGER {powerOff(1), powerOn(2)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Power 1 state
"
::= { powerStatus 1 }
powerStatus-PW2-state OBJECT-TYPE
SYNTAX INTEGER {powerOff(1), powerOn(2)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Power 2 state
"
::= { powerStatus 2 }
--***********************
-- Serial interface
-- ------------------------