-- 3Com Switching Systems Management Information Base
|
|
-- Version 1.0.0
|
|
-- February 13, 1998
|
|
|
|
-- 3Com Corporation
|
|
-- 80 Central Street
|
|
-- Boxborough, MA 01719
|
|
-- (508) 264-1400
|
|
|
|
----------------------------------------------------------------------------------------
|
|
--
|
|
-- 03/09/98 - bbm Added a3ComSysBridgePortReceiveMulticastLimitMultiplier.
|
|
-- 02/26/98 - eah Added port1000NotPresent.
|
|
-- 02/13/98 - iwolf Originally created
|
|
--
|
|
----------------------------------------------------------------------------------------
|
|
|
|
A3COM-SWITCHING-SYSTEMS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
enterprises, Counter, Gauge, IpAddress FROM RFC1155-SMI
|
|
DisplayString FROM RFC1213-MIB
|
|
OBJECT-TYPE FROM RFC-1212
|
|
TRAP-TYPE FROM RFC-1215;
|
|
|
|
|
|
-- Textual conventions
|
|
|
|
RowStatus ::= INTEGER {
|
|
|
|
-- the following two values are states:
|
|
-- these values may be read or written
|
|
active(1),
|
|
notInService(2),
|
|
|
|
-- the following value is a state:
|
|
-- this value may be read, but not written
|
|
notReady(3),
|
|
|
|
-- the following three values are
|
|
-- actions: these values may be written,
|
|
-- but are never read
|
|
createAndGo(4),
|
|
createAndWait(5),
|
|
destroy(6)
|
|
}
|
|
|
|
|
|
-- Switching Systems Storage Type
|
|
|
|
A3ComSysStorageType ::= INTEGER (1..3)
|
|
--storageTypeUnknown(1), (not settable)
|
|
--storageNonVolatileMemory(2),
|
|
--storageFlashMemory(3)
|
|
|
|
-- Switching Systems Address Type
|
|
|
|
A3ComSysAddressType ::= INTEGER ( 1..2 )
|
|
--addrTypeUnknown(1), (not settable)
|
|
--addrIp(2)
|
|
|
|
-- Switching Systems Resource Type
|
|
|
|
A3ComSysResourceType ::= INTEGER ( 1..3 )
|
|
--resourceTypeUnknown(1), (not settable)
|
|
--resourceSystem(2)
|
|
--resourceBridge(3)
|
|
|
|
|
|
-- Switching Systems Resource Bit Mask
|
|
--
|
|
-- This type represents a variable length bit mask
|
|
-- encoded as an octet string in which the bits are
|
|
-- numbered from left-to-right.
|
|
--
|
|
-- Example: For an octet string with a length of 4:
|
|
--
|
|
-- Byte 0 Byte 1 Byte 2 Byte 3
|
|
-- Bits: 76543210 76543210 76543210 76543210
|
|
--
|
|
-- Bit String Indices:
|
|
--
|
|
-- Byte Bit Index
|
|
-- ==== ==== =====
|
|
-- 0 7 1
|
|
-- 0 6 2
|
|
-- 0 5 3
|
|
-- . . .
|
|
-- . . .
|
|
-- 1 7 9
|
|
-- 1 6 10
|
|
-- 1 5 11
|
|
-- . . .
|
|
-- . . .
|
|
-- 4 7 25
|
|
-- 4 6 26
|
|
-- 4 5 27
|
|
-- . . .
|
|
-- . . .
|
|
|
|
A3ComSysResourceBitMask ::= OCTET STRING (SIZE(4))
|
|
|
|
|
|
IpxNetworkNumber ::= OCTET STRING (SIZE(4))
|
|
|
|
ATNetworkNumber ::=
|
|
-- 2 octets of net number
|
|
-- in network byte order
|
|
OCTET STRING (SIZE (2))
|
|
|
|
ATName ::=
|
|
-- 0 to 32 octets of AppleTalk
|
|
-- ASCII [Inside AppleTalk]
|
|
OCTET STRING (SIZE (0..32))
|
|
|
|
DdpNodeAddress ::=
|
|
-- 2 octets of net number
|
|
-- in network byte order,
|
|
-- 1 octet of node number
|
|
OCTET STRING (SIZE (3))
|
|
|
|
MacAddress ::=
|
|
-- a 6 octet address in
|
|
-- the "canonical" order
|
|
-- defined by IEEE 802.1a, i.e., as if it were transmitted least
|
|
-- significant bit first
|
|
OCTET STRING (SIZE (6))
|
|
|
|
--
|
|
-- Object identifiers
|
|
--
|
|
|
|
a3Com OBJECT IDENTIFIER ::= { enterprises 43 }
|
|
|
|
switchingSystems-mib OBJECT IDENTIFIER ::= { a3Com 29 }
|
|
|
|
switchingSystemsMibGroups OBJECT IDENTIFIER ::= { switchingSystems-mib 4 }
|
|
switchingSystemsFddiMibGroups OBJECT IDENTIFIER ::= { switchingSystems-mib 10 }
|
|
|
|
-- switchingSystemsMib groups.
|
|
|
|
a3ComSysSystem OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 1 }
|
|
a3ComSysSlot OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 2 }
|
|
a3ComSysControlPanel OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 3 }
|
|
a3ComSysPowerSupply OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 4 }
|
|
a3ComSysSnmp OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 5 }
|
|
a3ComSysAgent OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 6 }
|
|
a3ComSysInterface OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 7 }
|
|
a3ComSysEthernetPort OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 8 }
|
|
a3ComSysSmt OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 9 }
|
|
a3ComSysBridge OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 10 }
|
|
a3ComSysIpRouter OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 11 }
|
|
a3ComSysNetworkMonitor OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 12 }
|
|
a3ComSysTokenRingPort OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 13 }
|
|
a3ComSysFtGroup OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 14 }
|
|
a3ComSysIpGroup OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 15 }
|
|
a3ComSysIpxGroup OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 16 }
|
|
a3ComSysAppleTalkGroup OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 17 }
|
|
a3ComSysModuleCardGroup OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 18 }
|
|
a3ComSysDiagnosticsGroup OBJECT IDENTIFIER ::= { switchingSystemsMibGroups 19 }
|
|
|
|
|
|
|
|
-- The Switching Systems MIB system group. Implementation of this
|
|
-- group is mandatory for agents which manage system resources.
|
|
|
|
a3ComSysSystemId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unique identifier assigned to this system during
|
|
manufacturing."
|
|
::= { a3ComSysSystem 1 }
|
|
|
|
a3ComSysSystemType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
lanplex6000(2),
|
|
lanplex2000(3),
|
|
coreBuilder3500(4),
|
|
coreBuilder9400(5),
|
|
superStack3900(6),
|
|
superStack9300(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of system."
|
|
::= { a3ComSysSystem 2 }
|
|
|
|
a3ComSysSystemName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The text string describing this system."
|
|
::= { a3ComSysSystem 3 }
|
|
|
|
a3ComSysSystemManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..127))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The text string describing the manufacturer of this
|
|
system."
|
|
::= { a3ComSysSystem 4 }
|
|
|
|
a3ComSysSystemHardwareRevision OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (2))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The revision level of the system, contained in two
|
|
octets. The first octet indicates the artwork revision,
|
|
and the second octet indicates the rework level."
|
|
::= { a3ComSysSystem 5 }
|
|
|
|
a3ComSysSystemMemorySize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of memory (RAM), in bytes, present on the
|
|
system processor board."
|
|
::= { a3ComSysSystem 6 }
|
|
|
|
a3ComSysSystemFlashMemorySize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of flash memory, in bytes, present on the
|
|
system processor board."
|
|
::= { a3ComSysSystem 7 }
|
|
|
|
a3ComSysSystemNvMemorySize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of non-volatile memory, in bytes, present
|
|
on the system processor board."
|
|
::= { a3ComSysSystem 8 }
|
|
|
|
a3ComSysSystemSoftwareRevision OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The revision number of the Switching Systems software.
|
|
Each byte indicates the following:
|
|
byte 0: major release number.
|
|
byte 1: minor release number.
|
|
byte 2: update number.
|
|
byte 3:
|
|
bits 7-6: release type.
|
|
bits 5-0: supplemental identifier."
|
|
::= { a3ComSysSystem 9 }
|
|
|
|
a3ComSysSystemBuildTime OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..127))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The build time of the system software."
|
|
::= { a3ComSysSystem 10 }
|
|
|
|
a3ComSysSystemSnmpRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The revision number of the SNMP agent implementation."
|
|
::= { a3ComSysSystem 11 }
|
|
|
|
a3ComSysSystemRequestedSnmpMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
singleAgentMode(1),
|
|
multiAgentMode(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object describes the requested SNMP mode for the
|
|
system. The value of this object indicates the mode that
|
|
will become effective following a reboot of the system.
|
|
Note that only a subset of the above values may be valid
|
|
for some systems."
|
|
::= { a3ComSysSystem 12 }
|
|
|
|
a3ComSysSystemCurrentSnmpMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
singleAgentMode(1),
|
|
multiAgentMode(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object describes the currently active SNMP mode for
|
|
the system. Note that only a subset of the above values
|
|
may be valid for some systems."
|
|
::= { a3ComSysSystem 13 }
|
|
|
|
a3ComSysSystemAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
reset(2),
|
|
nvReset(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object, when read, always returns the value other(1).
|
|
|
|
Setting this object to the value reset(2) causes a reset
|
|
of the system.
|
|
|
|
Setting this object to the value nvReset(3) causes the
|
|
system's non-volatile configuration to be reset to the
|
|
default values.
|
|
|
|
The value other(1) is not a vaild value for set operations."
|
|
::= { a3ComSysSystem 14 }
|
|
|
|
a3ComSysSystemOvertemperature OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
true(1),
|
|
false(2),
|
|
notSupported(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object indicates the current overtemperature
|
|
status for the system. If the system does not support
|
|
overtemperature detection, this object returns
|
|
notSupported."
|
|
::= { a3ComSysSystem 15 }
|
|
|
|
a3ComSysSystemFanFailure OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
true(1),
|
|
false(2),
|
|
notSupported(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object indicates the current fan status for the
|
|
system. If the system does not support fan failure
|
|
detection, this object returns notSupported."
|
|
::= { a3ComSysSystem 16 }
|
|
|
|
a3ComSysSystemProtocolMask OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is a bit mask that indicates which protocols
|
|
exist in the software image currently loaded in memory.
|
|
The value of this OBJECT is a sum. It initially takes
|
|
on the value 0, then for each protocol bit as defined
|
|
below, 2 raised to the value of the (bit position - 1)
|
|
is added to the sum.
|
|
|
|
The following bits are defined:
|
|
|
|
IP_ROUTING 0x00000001
|
|
IPX_ROUTING 0x00000002
|
|
DDP_ROUTING 0x00000004
|
|
|
|
A value of 0x00000000 indicates the
|
|
standard switching software."
|
|
::= { a3ComSysSystem 17 }
|
|
|
|
a3ComSysSystemConsoleAccess OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1), -- Console Access is permitted (unlocked)
|
|
disabled (2) -- Console Access is prohibited (locked)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object determines whether another device
|
|
can remotely access the system console via Telnet,
|
|
Rlogin, or modem port.
|
|
|
|
An existing remote session will not be terminated
|
|
when this value is modified."
|
|
::= { a3ComSysSystem 18 }
|
|
|
|
a3ComSysSystemConsoleReadPwd OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is the console read-access password."
|
|
::= { a3ComSysSystem 19 }
|
|
|
|
a3ComSysSystemConsoleWritePwd OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is the console write-access password. The
|
|
read-write community string is required for access to this
|
|
object."
|
|
::= { a3ComSysSystem 20 }
|
|
|
|
a3ComSysSystemConsoleAdminPwd OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is the console admin-access password. The
|
|
read-write community string is required for access to this
|
|
object."
|
|
::= { a3ComSysSystem 21 }
|
|
|
|
|
|
a3ComSysSystemDateTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current date and time as reflected by the
|
|
system clock in the format mm/dd/yy hh:mm:ss xM."
|
|
::= { a3ComSysSystem 22 }
|
|
|
|
a3ComSysSystemDSTime OBJECT-TYPE
|
|
SYNTAX INTEGER (-120..120)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter specifies the displacement, in
|
|
minutes, from non-daylight savings time. The
|
|
a3ComSysDSTime object, along with the a3ComSysTimeZone
|
|
object, allows the system to support Universal
|
|
time for network communications spanning different
|
|
time zones."
|
|
::= { a3ComSysSystem 23 }
|
|
|
|
a3ComSysSystemTimeZone OBJECT-TYPE
|
|
SYNTAX INTEGER (-720..720)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter specifies, in minutes,
|
|
displacement of the system west of Greenwich.
|
|
A negative number for this parameter indicates how
|
|
many minutes displacement east of Greenwich
|
|
the site is located. A positive number
|
|
indicates the number of minutes west of Greenwich."
|
|
::= { a3ComSysSystem 24 }
|
|
|
|
a3ComSysSystemCurrentFddiStationMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
singleStationMode(1),
|
|
multiStationMode(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object describes the current FDDI station
|
|
mode for systems that support multi-station mode."
|
|
::= { a3ComSysSystem 25 }
|
|
|
|
a3ComSysSystemRequestedFddiStationMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
singleStationMode(1),
|
|
multiStationMode(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object describes the requested FDDI station
|
|
mode for systems that support multi-station mode.
|
|
The requested mode will become current during
|
|
the next system reboot."
|
|
::= { a3ComSysSystem 26 }
|
|
|
|
a3ComSysSystemLog OBJECT IDENTIFIER ::= { a3ComSysSystem 27 }
|
|
|
|
a3ComSysSystemLogEntryCurrentCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries currently recorded in the system log."
|
|
::= { a3ComSysSystemLog 1 }
|
|
|
|
a3ComSysSystemLogMaxSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum number of events that can be recorded in the system log."
|
|
::= { a3ComSysSystemLog 2 }
|
|
|
|
a3ComSysSystemLogSeverityThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{ informational(1),
|
|
warning(2),
|
|
error(3),
|
|
fatal(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object determines the miminum serverety level of events recorded in the
|
|
system log. For example, if the a3ComSysSysteLogSeverityThreshold is set to errors(3)
|
|
than only events which have serverity levels of error(3) or higher will
|
|
be recorded."
|
|
::= { a3ComSysSystemLog 3 }
|
|
|
|
a3ComSysSystemLogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysSystemLogEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table provides information on recorded system events."
|
|
::= { a3ComSysSystemLog 4 }
|
|
|
|
a3ComSysSystemLogEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysSystemLogEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A system log entry."
|
|
INDEX { a3ComSysSystemLogIndex }
|
|
::= { a3ComSysSystemLogTable 1 }
|
|
|
|
A3ComSysSystemLogEntry ::= SEQUENCE {
|
|
a3ComSysSystemLogIndex INTEGER,
|
|
a3ComSysSystemLogSeverityLevel INTEGER,
|
|
a3ComSysSystemLogDateTime DisplayString,
|
|
a3ComSysSystemLogFacility INTEGER,
|
|
a3ComSysSystemLogMessage DisplayString
|
|
}
|
|
|
|
a3ComSysSystemLogIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the log entry relative to this entry."
|
|
::= { a3ComSysSystemLogEntry 1 }
|
|
|
|
a3ComSysSystemLogSeverityLevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
information(1),
|
|
warning(2),
|
|
error(3),
|
|
fatal(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the severity level of the log entry."
|
|
::= { a3ComSysSystemLogEntry 2 }
|
|
|
|
a3ComSysSystemLogDateTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the date and time of the log event and is formatted
|
|
as follows: MM:DD:YY HH:MM:SS."
|
|
::= { a3ComSysSystemLogEntry 3 }
|
|
|
|
|
|
a3ComSysSystemLogFacility OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exception(1),
|
|
operatingSystem(2),
|
|
assertion(3),
|
|
spanningTree(4),
|
|
fcmlmm(5),
|
|
lmmfddi(6),
|
|
lmmboard(7),
|
|
esm(8),
|
|
trsm(9),
|
|
efsm(10),
|
|
fsm(11),
|
|
hsi(12)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The facility which entered the event in the log. fcmlmm(6) represents
|
|
those events which may be common to the Lanplex Management Module
|
|
(LMM) and the FDDI Concentrator Module (FCM). lmmfddi(6) represents
|
|
those events specific to the FDDI portion of the LMM and lmmboard
|
|
represents general events logged by the LMM."
|
|
::= { a3ComSysSystemLogEntry 4 }
|
|
|
|
a3ComSysSystemLogMessage OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The recorded log message."
|
|
::= { a3ComSysSystemLogEntry 5 }
|
|
|
|
a3ComSysSystemBaseMACAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The base MAC address for the system."
|
|
::= { a3ComSysSystem 28 }
|
|
|
|
a3ComSysSystemMACAddressCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of MAC addresses allocated to this system."
|
|
::= { a3ComSysSystem 29 }
|
|
|
|
a3ComSysSystemChassisSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(12))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the chassis."
|
|
::= { a3ComSysSystem 30 }
|
|
|
|
a3ComSysSystemFPMemorySize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of frame processor memory (RAM), in bytes."
|
|
::= { a3ComSysSystem 31 }
|
|
|
|
a3ComSysSystemBufferSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of buffer memory, in bytes."
|
|
::= { a3ComSysSystem 32 }
|
|
|
|
|
|
-- The Switching Systems MIB slot group. Implementation of this
|
|
-- group is mandatory for agents which manage system resources
|
|
-- for systems with independently manageable slots.
|
|
|
|
a3ComSysSlotCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The count of slots in the chassis."
|
|
::= { a3ComSysSlot 1 }
|
|
|
|
-- The Switching Systems MIB slot table.
|
|
|
|
a3ComSysSlotTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysSlotEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of slot entries. A single entry exists in this
|
|
list for each slot in the chassis."
|
|
::= { a3ComSysSlot 2 }
|
|
|
|
a3ComSysSlotEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysSlotEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A slot entry contains information about a particular
|
|
slot."
|
|
INDEX { a3ComSysSlotIndex }
|
|
::= { a3ComSysSlotTable 1 }
|
|
|
|
A3ComSysSlotEntry ::=
|
|
SEQUENCE {
|
|
a3ComSysSlotIndex
|
|
INTEGER,
|
|
a3ComSysSlotBoardType
|
|
INTEGER,
|
|
a3ComSysSlotBoardRevision
|
|
OCTET STRING,
|
|
a3ComSysSlotBoardStatus
|
|
INTEGER,
|
|
a3ComSysSlotBoardName
|
|
DisplayString,
|
|
a3ComSysSlotBoardNameAbbrev
|
|
DisplayString,
|
|
a3ComSysSlotEthernetPortCount
|
|
INTEGER,
|
|
a3ComSysSlotFddiMacCount
|
|
INTEGER,
|
|
a3ComSysSlotFddiPortCount
|
|
INTEGER,
|
|
a3ComSysSlotOvertemperature
|
|
INTEGER,
|
|
a3ComSysSlotTokenRingPortCount
|
|
INTEGER,
|
|
a3ComSysSlotBoardRevStr
|
|
DisplayString,
|
|
a3ComSysSlotConverterBad
|
|
INTEGER
|
|
}
|
|
|
|
a3ComSysSlotIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the slot identified by this entry."
|
|
::= { a3ComSysSlotEntry 1 }
|
|
|
|
a3ComSysSlotBoardType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
emptyLocation(2),
|
|
esmBoard(7),
|
|
fcmBoard(8),
|
|
lmmBoard(9),
|
|
efsmBoard(10),
|
|
trsmBoard(11),
|
|
tmmBoard(12),
|
|
fsmBoard(13),
|
|
fesmBoard(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of board residing in the slot identified by
|
|
this entry."
|
|
::= { a3ComSysSlotEntry 2 }
|
|
|
|
a3ComSysSlotBoardRevision OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..1))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The revision number of the board in the slot identified
|
|
by this entry. If the slot is empty, or the revision is
|
|
unknown this object returns a zero length string."
|
|
::= { a3ComSysSlotEntry 3 }
|
|
|
|
a3ComSysSlotBoardStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPresent(1),
|
|
testing(2),
|
|
offline(3),
|
|
online(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the board in the slot identified by this
|
|
entry."
|
|
::= { a3ComSysSlotEntry 4 }
|
|
|
|
a3ComSysSlotBoardName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The text string describing the board in the slot
|
|
identified by this entry."
|
|
::= { a3ComSysSlotEntry 5 }
|
|
|
|
a3ComSysSlotBoardNameAbbrev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The abbreviation used to describe the board in the slot
|
|
identified by this entry."
|
|
::= { a3ComSysSlotEntry 6 }
|
|
|
|
a3ComSysSlotEthernetPortCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The count of ethernet ports in the slot identified by
|
|
this entry."
|
|
::= { a3ComSysSlotEntry 7 }
|
|
|
|
a3ComSysSlotFddiMacCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The count of FDDI MACs in the slot identified by this
|
|
entry."
|
|
::= { a3ComSysSlotEntry 8 }
|
|
|
|
a3ComSysSlotFddiPortCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The count of FDDI ports in the slot identified by this
|
|
entry."
|
|
::= { a3ComSysSlotEntry 9 }
|
|
|
|
a3ComSysSlotOvertemperature OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
true(1),
|
|
false(2),
|
|
notSupported(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object indicates the current overtemperature status
|
|
for the slot. If the slot does not support overtemperature
|
|
detection, this object returns notSupported."
|
|
::= { a3ComSysSlotEntry 10 }
|
|
|
|
a3ComSysSlotTokenRingPortCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The count of TokenRing ports in the slot identified by this
|
|
entry."
|
|
::= { a3ComSysSlotEntry 11 }
|
|
|
|
a3ComSysSlotBoardRevStr OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..5))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This revision number of the board in the slot identified
|
|
by this entry. If the slot is empty, or the revision is
|
|
unknown this object returns a zero length string. The
|
|
format of the string is XX.YY, where the XX is the major
|
|
revision (artwork), the YY is the minor revision (rework)"
|
|
::= { a3ComSysSlotEntry 12 }
|
|
|
|
a3ComSysSlotConverterBad OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
true(1),
|
|
false(2),
|
|
notSupported(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object indicates the current status +12V->+5V
|
|
converter for the slot. If the slot does not support
|
|
+12V->+5V converter detection, this object returns
|
|
notSupported."
|
|
::= { a3ComSysSlotEntry 13 }
|
|
|
|
|
|
-- The LANplex Systems MIB control panel group. Implementation of
|
|
-- this group is mandatory for agents which manage system resources
|
|
-- for systems which are equipped with manageable control panels.
|
|
|
|
a3ComSysControlPanelHardwareRevision OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (1))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An 8-bit value specifying the revision level of the
|
|
control panel hardware."
|
|
::= { a3ComSysControlPanel 1 }
|
|
|
|
a3ComSysControlPanelSoftwareRevision OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (1))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An 8-bit value specifying the revision level of the
|
|
control panel software."
|
|
::= { a3ComSysControlPanel 2 }
|
|
|
|
a3ComSysControlPanelLines OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of lines in the control panel display."
|
|
::= { a3ComSysControlPanel 3 }
|
|
|
|
a3ComSysControlPanelColumns OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of columns in the control panel display."
|
|
::= { a3ComSysControlPanel 4 }
|
|
|
|
a3ComSysControlPanelText OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..127))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The currently displayed text in the control panel
|
|
display."
|
|
::= { a3ComSysControlPanel 5 }
|
|
|
|
a3ComSysControlPanelAccess OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1), -- Panel Access is permitted (unlocked)
|
|
disabled (2) -- Panel Access is prohibited (locked)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object determines whether modifications to system
|
|
configuration are allowed via the Control Panel"
|
|
::= { a3ComSysControlPanel 6 }
|
|
|
|
|
|
-- The Switching Systems MIB power supply group. Implementation of this
|
|
-- group is mandatory for agents which manage system resources for
|
|
-- systems which are equipped with managable power supplies.
|
|
|
|
a3ComSysPowerSupplyCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The count of power supplies in the system."
|
|
::= { a3ComSysPowerSupply 1 }
|
|
|
|
-- The Switching Systems MIB power supply status table.
|
|
|
|
a3ComSysPowerSupplyStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysPowerSupplyStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of power supply status entries."
|
|
::= { a3ComSysPowerSupply 2 }
|
|
|
|
a3ComSysPowerSupplyStatusEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysPowerSupplyStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A power supply status entry contains information about a
|
|
particular power supply."
|
|
INDEX { a3ComSysPowerSupplyStatusIndex }
|
|
::= { a3ComSysPowerSupplyStatusTable 1 }
|
|
|
|
A3ComSysPowerSupplyStatusEntry ::=
|
|
SEQUENCE {
|
|
a3ComSysPowerSupplyStatusIndex
|
|
INTEGER,
|
|
a3ComSysPowerSupplyStatus
|
|
INTEGER,
|
|
a3ComSysPowerSupplyStatusSupported
|
|
INTEGER
|
|
}
|
|
|
|
a3ComSysPowerSupplyStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unique index of the power supply identified by this
|
|
entry."
|
|
::= { a3ComSysPowerSupplyStatusEntry 1 }
|
|
|
|
a3ComSysPowerSupplyStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object represents the power supply status. The
|
|
value is a sum. It initially takes on the value 0, then
|
|
for each type which is active, 2 raised to a power is
|
|
added to the sum. The powers are according to the
|
|
following table.
|
|
For the 6000 Backbone Aggregator an over temp for power
|
|
supply 1 and power supply 2 will be reported as a power
|
|
supply 1 Over Temperature Failure, and a fan failure will
|
|
be reported as a power supply 2 Over Temperature Failure.
|
|
|
|
Failure Type Power
|
|
AC Failure 0
|
|
Plus 5 Failure 1
|
|
Plus 12 Failure 2
|
|
Over Temperature Failure 3
|
|
Power Supply Inserted 4
|
|
Power Supply Extracted 5"
|
|
::= { a3ComSysPowerSupplyStatusEntry 2 }
|
|
|
|
a3ComSysPowerSupplyStatusSupported OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object represents the various power supply status
|
|
types which are supported. The value is a sum. It
|
|
initially takes on the value 0, then for each type
|
|
which is supported, 2 raised to a power is added to the
|
|
sum. The powers are according to the following table:
|
|
|
|
Failure Type Power
|
|
AC Failure 0
|
|
Plus 5 Failure 1
|
|
Plus 12 Failure 2
|
|
Over Temperature Failure 3
|
|
Power Supply Inserted 4
|
|
Power Supply Extracted 5
|
|
|
|
This object used in conjunction with the
|
|
a3ComSysPowerSupplyStatus object for a given power supply
|
|
provide a complete picture of the status of the power
|
|
supply."
|
|
::= { a3ComSysPowerSupplyStatusEntry 3 }
|
|
|
|
|
|
-- The LANplex Systems MIB SNMP group. Implementation of this group
|
|
-- is mandatory for agents in systems which contain multiple
|
|
-- independently manageable devices and which support a multiple agent
|
|
-- mode. Note that this group is only available in the multiple agent
|
|
-- mode for those systems that support it.
|
|
|
|
a3ComSysSnmpAgentId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unique id for this SNMP agent within the system."
|
|
::= { a3ComSysSnmp 1 }
|
|
|
|
a3ComSysSnmpInternalAgentTrapMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value is a bit string that indicates which traps
|
|
are enabled for transmit to other agents in the system.
|
|
The octet string value is treated as a 64-bit integer
|
|
value. The value is a sum. It initially takes on the
|
|
value 0, then for each trap which is enabled, 2 raised
|
|
to the value of (a3ComSysAgentTrapDescriptionIndex - 1) for
|
|
that trap is added to the sum."
|
|
::= { a3ComSysSnmp 2 }
|
|
|
|
a3ComSysSnmpInternalAgentTrapDestinationMask OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A value which indicates to which other agents in the
|
|
system traps should be sent. The value is a sum. It
|
|
initially takes on the value 0, then for each agent which
|
|
is to receive traps, 2 raised to the value of
|
|
(a3ComSysSnmpAgentId - 1) for that agent is added to the sum.
|
|
Note that only traps which are enabled according to the
|
|
value of the a3ComSysSnmpInternalAgentTrapMask object will be
|
|
forwarded, and that each trap which is forwarded will
|
|
be transmitted to each agent identified by this mask."
|
|
::= { a3ComSysSnmp 3 }
|
|
|
|
a3ComSysSnmpProxyInternalRequests OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
true(1),
|
|
false(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object determines if this agent will proxy requests
|
|
to other agents in the system. If the value of this
|
|
object is true(1), this agent will proxy requests to other
|
|
agents in the chassis."
|
|
::= { a3ComSysSnmp 4 }
|
|
|
|
a3ComSysSnmpInternalProxyRequestMaxAge OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum time, in seconds, an internal proxy request
|
|
will remain queued waiting for a response before being
|
|
discarded. Note that when the value of
|
|
a3ComSysSnmpProxyInternalRequests is false(2), the value of
|
|
this object is ignored."
|
|
::= { a3ComSysSnmp 5 }
|
|
|
|
a3ComSysSnmpProxyInternalTraps OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
true(1),
|
|
false(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object determines if this agent will generate proxy
|
|
traps for those traps received from other agents in the
|
|
system. If the value of this object is true(1), this
|
|
agent will generate proxy traps for those received from
|
|
other agents in the chassis. Note that agents will not
|
|
proxy traps to other agents within the system to prevent
|
|
looping of traps."
|
|
::= { a3ComSysSnmp 6 }
|
|
|
|
|
|
-- The LANplex Systems MIB SNMP internal proxy table.
|
|
|
|
a3ComSysSnmpInternalProxyTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysSnmpInternalProxyEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of SNMP internal agent proxy entries. An entry in
|
|
this table exists for each agent in the system that can be
|
|
reached by this agent via the internal proxy mechanism."
|
|
::= { a3ComSysSnmp 7 }
|
|
|
|
a3ComSysSnmpInternalProxyEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysSnmpInternalProxyEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry identifies the communities available for
|
|
communicating with another agent in the system via the
|
|
internal proxy mechanism."
|
|
INDEX { a3ComSysSnmpInternalProxyAgentId,
|
|
a3ComSysSnmpInternalProxyAccessClass }
|
|
::= { a3ComSysSnmpInternalProxyTable 1 }
|
|
|
|
A3ComSysSnmpInternalProxyEntry ::=
|
|
SEQUENCE {
|
|
a3ComSysSnmpInternalProxyAgentId
|
|
INTEGER,
|
|
a3ComSysSnmpInternalProxyAccessClass
|
|
INTEGER,
|
|
a3ComSysSnmpInternalProxyCommunity
|
|
OCTET STRING
|
|
}
|
|
|
|
a3ComSysSnmpInternalProxyAgentId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The id of the agent identified by this entry."
|
|
::= { a3ComSysSnmpInternalProxyEntry 1 }
|
|
|
|
a3ComSysSnmpInternalProxyAccessClass OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
readOnly(1),
|
|
readWrite(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The access to MIB objects supported by the agent
|
|
identified by this entry provided by this agent, when
|
|
using the community string identified by the corresponding
|
|
value of a3ComSysSnmpInternalProxyCommunity."
|
|
::= { a3ComSysSnmpInternalProxyEntry 2 }
|
|
|
|
a3ComSysSnmpInternalProxyCommunity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A community which allows access to MIB objects supported
|
|
by the agent identified by this entry."
|
|
::= { a3ComSysSnmpInternalProxyEntry 3 }
|
|
|
|
|
|
|
|
-- The Switching Systems MIB agent group. Implementation of this group
|
|
-- is mandatory for all agents.
|
|
|
|
a3ComSysAgentRequestMaxAge OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum time, in seconds, a local SNMP request will
|
|
remain queued waiting for a response before being
|
|
discarded."
|
|
::= { a3ComSysAgent 1 }
|
|
|
|
a3ComSysAgentProxyRemoteSmtRequests OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
true(1),
|
|
false(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object determines if this agent will proxy SMT
|
|
requests to other FDDI stations. If the value of this
|
|
object is true(1), this agent will proxy SMT requests to
|
|
other stations. Note that only a subset of the above
|
|
values may be valid for some systems."
|
|
::= { a3ComSysAgent 2 }
|
|
|
|
a3ComSysAgentRemoteSmtProxyRequestMaxAge OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum time, in seconds, an SMT proxy request will
|
|
remain queued waiting for a response before being
|
|
discarded. Note that when the value of
|
|
a3ComSysAgentProxyRemoteSmtRequests is false(2), the value of
|
|
this object is ignored."
|
|
::= { a3ComSysAgent 3 }
|
|
|
|
a3ComSysAgentProxyRemoteSmtEvents OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
true(1),
|
|
false(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object determines if this agent will generate traps
|
|
for SMT events occuring at other stations. If the value
|
|
of this object is true(1), this agent will generate traps
|
|
for all SMT events, those which occur locally, and those
|
|
which occur at other stations. If the value of this
|
|
object is false(2), this agent will only generate traps
|
|
for events which occur locally. Note that only a subset
|
|
of the above values may be valid for some systems."
|
|
::= { a3ComSysAgent 4 }
|
|
|
|
-- The Switching Systems MIB agent trap description table.
|
|
|
|
a3ComSysAgentTrapDescriptionTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysAgentTrapDescriptionTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains a listing of trap descriptions for
|
|
each trap supported by this agent. This
|
|
provides a relationship between a trap index, and the trap
|
|
enterprise oid and trap number for a given trap. In all
|
|
cases except for the MIB-2 generic traps, the enterprise
|
|
under which a trap is defined is the same as that
|
|
appearing in the ENTERPRISE portion of the trap."
|
|
::= { a3ComSysAgent 5 }
|
|
|
|
a3ComSysAgentTrapDescriptionTableEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysAgentTrapDescriptionTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Information relating a trap index to a specific trap
|
|
enterprise oid and trap number."
|
|
INDEX { a3ComSysAgentTrapDescriptionIndex }
|
|
::= { a3ComSysAgentTrapDescriptionTable 1 }
|
|
|
|
A3ComSysAgentTrapDescriptionTableEntry ::=
|
|
SEQUENCE {
|
|
a3ComSysAgentTrapDescriptionIndex
|
|
INTEGER,
|
|
a3ComSysAgentTrapEnterprise
|
|
OBJECT IDENTIFIER,
|
|
a3ComSysAgentTrapNumber
|
|
INTEGER
|
|
}
|
|
|
|
a3ComSysAgentTrapDescriptionIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique index corresponding to the trap described by
|
|
this entry. This value of this object corresponding to
|
|
a particular trap will remain constant accross system
|
|
resets."
|
|
::= { a3ComSysAgentTrapDescriptionTableEntry 1 }
|
|
|
|
a3ComSysAgentTrapEnterprise OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The enterpise under which the trap identified by this
|
|
entry is defined."
|
|
::= { a3ComSysAgentTrapDescriptionTableEntry 2 }
|
|
|
|
a3ComSysAgentTrapNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of the trap identified by this entry, within
|
|
the enterprise where it is defined."
|
|
::= { a3ComSysAgentTrapDescriptionTableEntry 3 }
|
|
|
|
-- The Switching Systems MIB agent trap destination table.
|
|
|
|
a3ComSysAgentTrapDestinationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysAgentTrapDestinationTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains information specifying which traps
|
|
will be transmitted to a given destination address. The
|
|
table is indexed by the destination address type and
|
|
destination address. Each entry in the table with a
|
|
status of valid identifies a set of traps which, when
|
|
generated, will be transmitted to the corresponding
|
|
destination address listed in that entry."
|
|
::= { a3ComSysAgent 6 }
|
|
|
|
a3ComSysAgentTrapDestinationTableEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysAgentTrapDestinationTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Information relating a set of traps and a destination
|
|
address to which each trap in ths set will be transmitted
|
|
when it is generated. To create a new entry, set a
|
|
non-existent instance of a3ComSysAgentTrapDestinationTrapMask
|
|
to a valid value. To remove an entry, set the instance of
|
|
a3ComSysAgentTrapDestinationEntryStatus for the entry to
|
|
invalid(2)."
|
|
INDEX { a3ComSysAgentTrapDestinationAddressType,
|
|
a3ComSysAgentTrapDestinationAddress }
|
|
::= { a3ComSysAgentTrapDestinationTable 1 }
|
|
|
|
A3ComSysAgentTrapDestinationTableEntry ::=
|
|
SEQUENCE {
|
|
a3ComSysAgentTrapDestinationAddressType
|
|
INTEGER,
|
|
a3ComSysAgentTrapDestinationAddress
|
|
OCTET STRING,
|
|
a3ComSysAgentTrapDestinationTrapMask
|
|
OCTET STRING,
|
|
a3ComSysAgentTrapDestinationEntryStatus
|
|
INTEGER
|
|
}
|
|
|
|
a3ComSysAgentTrapDestinationAddressType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ip(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of address identified by this entry."
|
|
::= { a3ComSysAgentTrapDestinationTableEntry 1 }
|
|
|
|
a3ComSysAgentTrapDestinationAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The address, of the type specified by the corresponding
|
|
value of a3ComSysAgentTrapDestinationAddressType, to which the
|
|
set of traps identified by this entry are to be
|
|
transmitted."
|
|
::= { a3ComSysAgentTrapDestinationTableEntry 2 }
|
|
|
|
a3ComSysAgentTrapDestinationTrapMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value is a bit string that indicates which traps
|
|
are enabled for the address identified by this entry.
|
|
The octet string value is treated as a 64-bit value. The
|
|
value is a sum. It initially takes on the value 0, then
|
|
for each trap which is enabled, 2 raised to the value of
|
|
(a3ComSysAgentTrapDescriptionIndex - 1) for that trap is
|
|
added to the sum. A new entry in the table is created by
|
|
setting the value of this object for a new destination
|
|
address type and destination address. Note that an octet
|
|
string of all zeros is not a valid value for this object."
|
|
::= { a3ComSysAgentTrapDestinationTableEntry 3 }
|
|
|
|
a3ComSysAgentTrapDestinationEntryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
valid(1),
|
|
invalid(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the trap destination table entry. Setting
|
|
this object to invalid(1) has the effect of removing the
|
|
corresponding entry from the table."
|
|
::= { a3ComSysAgentTrapDestinationTableEntry 4 }
|
|
|
|
a3ComSysAgentReadCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..48))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is the read community string when access is
|
|
made via SNMP, see RFC1157."
|
|
::= { a3ComSysAgent 7 }
|
|
|
|
a3ComSysAgentReadWriteCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..48))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is the read-write community string when access is
|
|
made via SNMP, see RFC1157. The read-write community string
|
|
is required to access this object."
|
|
::= { a3ComSysAgent 8 }
|
|
|
|
|
|
-- The Switching Systems MIB interface group. Implementation of this
|
|
-- group is mandatory for all agents.
|
|
|
|
-- The Switching Systems MIB interface location table.
|
|
|
|
a3ComSysInterfaceLocationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysInterfaceLocationEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of interface location entries. A single entry
|
|
exists in this list for each interface managed by this
|
|
agent."
|
|
::= { a3ComSysInterface 1 }
|
|
|
|
a3ComSysInterfaceLocationEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysInterfaceLocationEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An interface location entry describes the location of
|
|
a particular interface managed by this agent."
|
|
INDEX { a3ComSysInterfaceLocationIfIndex }
|
|
::= { a3ComSysInterfaceLocationTable 1 }
|
|
|
|
A3ComSysInterfaceLocationEntry ::=
|
|
SEQUENCE {
|
|
a3ComSysInterfaceLocationIfIndex
|
|
INTEGER,
|
|
a3ComSysInterfaceLocationInterfaceType
|
|
INTEGER,
|
|
a3ComSysInterfaceLocationType
|
|
INTEGER,
|
|
a3ComSysInterfaceLocationTypeIndex
|
|
INTEGER,
|
|
a3ComSysInterfaceLocationLocalIndex
|
|
INTEGER,
|
|
a3ComSysInterfaceLocationSystemModuleIndex
|
|
INTEGER
|
|
}
|
|
|
|
a3ComSysInterfaceLocationIfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the MIB-II ifIndex corresponding to the
|
|
interface identified by this entry."
|
|
::= { a3ComSysInterfaceLocationEntry 1 }
|
|
|
|
|
|
a3ComSysInterfaceLocationInterfaceType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ethernetPort(2),
|
|
fddiMac(3),
|
|
tokenringPort(4),
|
|
atmPort(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of the physical implementation of the interface
|
|
identified by this entry."
|
|
::= { a3ComSysInterfaceLocationEntry 2 }
|
|
|
|
a3ComSysInterfaceLocationType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
modularSlot(2),
|
|
chassis(3),
|
|
modularCard(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of location where the interface identified
|
|
by this entry is physically located."
|
|
::= { a3ComSysInterfaceLocationEntry 3 }
|
|
|
|
a3ComSysInterfaceLocationTypeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the location identified by the corresponding
|
|
instance of a3ComSysInterfaceLocationType where the interface
|
|
identified by this entry is physically located."
|
|
::= { a3ComSysInterfaceLocationEntry 4 }
|
|
|
|
a3ComSysInterfaceLocationLocalIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The local index of the interface identified by
|
|
this entry relative to its type specified by the
|
|
corresponding value of a3ComSysInterfaceLocationInterfaceType,
|
|
and the location specified by the corresponding values
|
|
of a3ComSysInterfaceLocationType and a3ComSysInterfaceLocationTypeIndex."
|
|
::= { a3ComSysInterfaceLocationEntry 5 }
|
|
|
|
a3ComSysInterfaceLocationSystemModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system module index of the interface idnetified by
|
|
this entry. Ths index can be used to acquire the module
|
|
information from the s2SysModuleCardGroup and the
|
|
a3ComSysDiagnosticsGroup groups."
|
|
::= { a3ComSysInterfaceLocationEntry 6 }
|
|
-- The Switching Systems MIB ethernet port group. Implementation of
|
|
-- this group is mandatory for agents which manage ethernet port
|
|
-- resources.
|
|
|
|
a3ComSysEthernetPortCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The count of ethernet ports managed by this agent."
|
|
::= { a3ComSysEthernetPort 1 }
|
|
|
|
-- The Switching Systems MIB ethernet port table.
|
|
|
|
a3ComSysEthernetPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysEthernetPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of ethernet port entries. A single entry exists
|
|
in this list for each ethernet port managed by this agent."
|
|
::= { a3ComSysEthernetPort 2 }
|
|
|
|
a3ComSysEthernetPortEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysEthernetPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ethernet port entry contains information about a
|
|
particular ethernet port managed by this agent."
|
|
INDEX { a3ComSysEthernetPortIndex }
|
|
::= { a3ComSysEthernetPortTable 1 }
|
|
|
|
A3ComSysEthernetPortEntry ::=
|
|
SEQUENCE {
|
|
a3ComSysEthernetPortIndex
|
|
INTEGER,
|
|
a3ComSysEthernetPortIfIndex
|
|
INTEGER,
|
|
a3ComSysEthernetPortLabel
|
|
DisplayString,
|
|
a3ComSysEthernetPortLinkStatus
|
|
INTEGER,
|
|
a3ComSysEthernetPortType
|
|
INTEGER
|
|
}
|
|
|
|
a3ComSysEthernetPortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the ethernet port identified by this entry,
|
|
relative to this agent."
|
|
::= { a3ComSysEthernetPortEntry 1 }
|
|
|
|
a3ComSysEthernetPortIfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the MIB-II ifIndex corresponding to the
|
|
ethernet port identified by this entry."
|
|
::= { a3ComSysEthernetPortEntry 2 }
|
|
|
|
a3ComSysEthernetPortLabel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ASCII text string describing the ethernet port
|
|
identified by this entry."
|
|
::= { a3ComSysEthernetPortEntry 3 }
|
|
|
|
a3ComSysEthernetPortLinkStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
active(1),
|
|
inActive(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current value of the link status for the ethernet port
|
|
identified by this entry."
|
|
::= { a3ComSysEthernetPortEntry 4 }
|
|
|
|
a3ComSysEthernetPortType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
rj2110BaseT(1),
|
|
rj4510BaseT(2),
|
|
st10BaseFL(3),
|
|
aui(4),
|
|
bnc10Base2(5),
|
|
other(6),
|
|
rj45100BaseT(7),
|
|
sc100BaseFx(8),
|
|
untermBnc10Base2(9),
|
|
sc1000BaseLxSm(10),
|
|
sc1000BaseLxMm(11),
|
|
sc1000BaseLxSmMm(12),
|
|
sc1000BaseLx10km(13),
|
|
sc1000BaseSx(14),
|
|
hssdc1000BaseCx(15),
|
|
db91000BaseCx(16),
|
|
gbicNotPresent(17),
|
|
gbic1000BaseCxDb9(18),
|
|
gbic1000BaseCxHssdc(19),
|
|
gbic1000BaseLx10Km(20),
|
|
gbic1000BaseLx(21),
|
|
gbic1000BaseSx(22),
|
|
rj451000BaseT(23),
|
|
port1000NotPresent(24)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specific port type description for the ethernet port
|
|
identified by this entry."
|
|
::= { a3ComSysEthernetPortEntry 5 }
|
|
|
|
-- The Switching Systems MIB ethernet port rate table.
|
|
|
|
a3ComSysEthernetPortRateTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysEthernetPortRateEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of ethernet port rate entries. A single entry
|
|
exists in this list for each ethernet port, managed by
|
|
this agent, which supports rate information."
|
|
::= { a3ComSysEthernetPort 3 }
|
|
|
|
a3ComSysEthernetPortRateEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysEthernetPortRateEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ethernet port rate entry contains rate statistics for a
|
|
particular ethernet port managed by this agent. Rate
|
|
statistics are calculated based on a one second sampling
|
|
interval."
|
|
INDEX { a3ComSysEthernetPortRateIndex }
|
|
::= { a3ComSysEthernetPortRateTable 1 }
|
|
|
|
A3ComSysEthernetPortRateEntry ::=
|
|
SEQUENCE {
|
|
a3ComSysEthernetPortRateIndex
|
|
INTEGER,
|
|
a3ComSysEthernetPortRateByteReceiveRate
|
|
INTEGER,
|
|
a3ComSysEthernetPortRatePeakByteReceiveRate
|
|
INTEGER,
|
|
a3ComSysEthernetPortRateFrameReceiveRate
|
|
INTEGER,
|
|
a3ComSysEthernetPortRatePeakFrameReceiveRate
|
|
INTEGER,
|
|
a3ComSysEthernetPortRateByteTransmitRate
|
|
INTEGER,
|
|
a3ComSysEthernetPortRatePeakByteTransmitRate
|
|
INTEGER,
|
|
a3ComSysEthernetPortRateFrameTransmitRate
|
|
INTEGER,
|
|
a3ComSysEthernetPortRatePeakFrameTransmitRate
|
|
INTEGER
|
|
}
|
|
|
|
a3ComSysEthernetPortRateIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the ethernet port identified by this entry,
|
|
relative to this agent."
|
|
::= { a3ComSysEthernetPortRateEntry 1 }
|
|
|
|
a3ComSysEthernetPortRateByteReceiveRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The average number of bytes received per second by the
|
|
ethernet port identified by this entry during the most
|
|
recent sampling period."
|
|
::= { a3ComSysEthernetPortRateEntry 2 }
|
|
|
|
a3ComSysEthernetPortRatePeakByteReceiveRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The peak value of a3ComSysEthernetPortRateByteReceiveRate
|
|
since the system was last initialized for the ethernet
|
|
port identified by this entry."
|
|
::= { a3ComSysEthernetPortRateEntry 3 }
|
|
|
|
a3ComSysEthernetPortRateFrameReceiveRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The average number of frames received per second by the
|
|
ethernet port identified by this entry during the most
|
|
recent sampling period."
|
|
::= { a3ComSysEthernetPortRateEntry 4 }
|
|
|
|
a3ComSysEthernetPortRatePeakFrameReceiveRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The peak value of a3ComSysEthernetPortRateFrameReceiveRate
|
|
since the system was last initialized for the ethernet
|
|
port identified by this entry."
|
|
::= { a3ComSysEthernetPortRateEntry 5 }
|
|
|
|
a3ComSysEthernetPortRateByteTransmitRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The average number of bytes transmitted per second by the
|
|
ethernet port identified by this entry during the most
|
|
recent sampling period."
|
|
::= { a3ComSysEthernetPortRateEntry 6 }
|
|
|
|
a3ComSysEthernetPortRatePeakByteTransmitRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The peak value of a3ComSysEthernetPortRateByteTransmitRate
|
|
since the system was last initialized for the ethernet
|
|
port identified by this entry."
|
|
::= { a3ComSysEthernetPortRateEntry 7 }
|
|
|
|
a3ComSysEthernetPortRateFrameTransmitRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The average number of frames transmitted per second by the
|
|
ethernet port identified by this entry during the most
|
|
recent sampling period."
|
|
::= { a3ComSysEthernetPortRateEntry 8 }
|
|
|
|
a3ComSysEthernetPortRatePeakFrameTransmitRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The peak value of a3ComSysEthernetPortRateFrameTransmitRate
|
|
since the system was last initialized for the ethernet
|
|
port identified by this entry."
|
|
::= { a3ComSysEthernetPortRateEntry 9 }
|
|
|
|
|
|
-- The Switching Systems MIB SMT group. Implementation of this group is
|
|
-- mandatory for agents which manage SMT resources.
|
|
|
|
a3ComSysSmtCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The count of SMTs managed by this agent."
|
|
::= { a3ComSysSmt 1 }
|
|
|
|
-- The Switching Systems MIB SMT table.
|
|
-- This table is currently unused and is reserved for future use.
|
|
-- { a3ComSysSmt 2 }
|
|
|
|
-- The Switching Systems MIB SMT FDDI MAC table.
|
|
-- This table is currently unused and is reserved for future use.
|
|
-- { a3ComSysSmt 3 }
|
|
|
|
-- The Switching Systems MIB SMT FDDI MAC beacon table.
|
|
|
|
a3ComSysSmtFddiMacBeaconTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysSmtFddiMacBeaconEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of FDDI MAC beacon entries. A single entry exists
|
|
in this list for each FDDI MAC, managed by this agent,
|
|
which supports MAC beacon history."
|
|
::= { a3ComSysSmt 4 }
|
|
|
|
a3ComSysSmtFddiMacBeaconEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysSmtFddiMacBeaconEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An FDDI MAC beacon entry contains information about a
|
|
particular FDDI MAC's beacon history."
|
|
INDEX { a3ComSysSmtFddiMacBeaconSmtIndex,
|
|
a3ComSysSmtFddiMacBeaconIndex }
|
|
::= { a3ComSysSmtFddiMacBeaconTable 1 }
|
|
|
|
A3ComSysSmtFddiMacBeaconEntry ::=
|
|
SEQUENCE {
|
|
a3ComSysSmtFddiMacBeaconSmtIndex
|
|
INTEGER,
|
|
a3ComSysSmtFddiMacBeaconIndex
|
|
INTEGER,
|
|
a3ComSysSmtFddiMacBeaconHistory
|
|
OCTET STRING
|
|
}
|
|
|
|
a3ComSysSmtFddiMacBeaconSmtIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the SMT instance identified by this entry,
|
|
relative to this agent."
|
|
::= { a3ComSysSmtFddiMacBeaconEntry 1 }
|
|
|
|
a3ComSysSmtFddiMacBeaconIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the FDDI MAC identified by this entry,
|
|
within the SMT identified by this entry."
|
|
::= { a3ComSysSmtFddiMacBeaconEntry 2 }
|
|
|
|
a3ComSysSmtFddiMacBeaconHistory OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object gives a history of the most recent beacon
|
|
information received on the FDDI MAC identified by this
|
|
entry. It can contain up to a maximum of eight records.
|
|
Each record is of the form:
|
|
source MAC: 6 bytes
|
|
beacon data length: 2 bytes.
|
|
beacon data: 0-16 bytes."
|
|
::= { a3ComSysSmtFddiMacBeaconEntry 3 }
|
|
|
|
-- The Switching Systems MIB SMT FDDI MAC rate table.
|
|
|
|
a3ComSysSmtFddiMacRateTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysSmtFddiMacRateEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of FDDI MAC rate entries. A single entry exists
|
|
in this list for each FDDI MAC, managed by this agent,
|
|
which supports rate statistics."
|
|
::= { a3ComSysSmt 5 }
|
|
|
|
a3ComSysSmtFddiMacRateEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysSmtFddiMacRateEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An FDDI MAC rate entry contains rate statistics for a
|
|
particular FDDI MAC managed by this agent. Rate statistics
|
|
are calculated based on a one second sampling interval."
|
|
INDEX { a3ComSysSmtFddiMacRateSmtIndex,
|
|
a3ComSysSmtFddiMacRateIndex }
|
|
::= { a3ComSysSmtFddiMacRateTable 1 }
|
|
|
|
A3ComSysSmtFddiMacRateEntry ::=
|
|
SEQUENCE {
|
|
a3ComSysSmtFddiMacRateSmtIndex
|
|
INTEGER,
|
|
a3ComSysSmtFddiMacRateIndex
|
|
INTEGER,
|
|
a3ComSysSmtFddiMacRateByteReceiveRate
|
|
INTEGER,
|
|
a3ComSysSmtFddiMacRatePeakByteReceiveRate
|
|
INTEGER,
|
|
a3ComSysSmtFddiMacRateFrameReceiveRate
|
|
INTEGER,
|
|
a3ComSysSmtFddiMacRatePeakFrameReceiveRate
|
|
INTEGER,
|
|
a3ComSysSmtFddiMacRateByteTransmitRate
|
|
INTEGER,
|
|
a3ComSysSmtFddiMacRatePeakByteTransmitRate
|
|
INTEGER,
|
|
a3ComSysSmtFddiMacRateFrameTransmitRate
|
|
INTEGER,
|
|
a3ComSysSmtFddiMacRatePeakFrameTransmitRate
|
|
INTEGER
|
|
}
|
|
|
|
a3ComSysSmtFddiMacRateSmtIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the SMT instance identified by this entry,
|
|
relative to this agent."
|
|
::= { a3ComSysSmtFddiMacRateEntry 1 }
|
|
|
|
a3ComSysSmtFddiMacRateIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the FDDI MAC identified by this entry, within
|
|
the SMT identified by this entry."
|
|
::= { a3ComSysSmtFddiMacRateEntry 2 }
|
|
|
|
a3ComSysSmtFddiMacRateByteReceiveRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The average number of bytes received per second by the
|
|
FDDI MAC identified by this entry during the most recent
|
|
sampling period."
|
|
::= { a3ComSysSmtFddiMacRateEntry 3 }
|
|
|
|
a3ComSysSmtFddiMacRatePeakByteReceiveRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The peak value of a3ComSysSmtFddiMacByteReceiveRate since the
|
|
system was last initialized for the FDDI MAC identified by
|
|
this entry."
|
|
::= { a3ComSysSmtFddiMacRateEntry 4 }
|
|
|
|
a3ComSysSmtFddiMacRateFrameReceiveRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The average number of frames received per second by the
|
|
FDDI MAC identified by this entry during the most recent
|
|
sampling period."
|
|
::= { a3ComSysSmtFddiMacRateEntry 5 }
|
|
|
|
a3ComSysSmtFddiMacRatePeakFrameReceiveRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The peak value of a3ComSysSmtFddiMacRateFrameReceiveRate since
|
|
the system was last initialized for the FDDI MAC identified
|
|
by this entry."
|
|
::= { a3ComSysSmtFddiMacRateEntry 6 }
|
|
|
|
a3ComSysSmtFddiMacRateByteTransmitRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The average number of bytes transmitted per second by the
|
|
FDDI MAC identified by this entry during the most recent
|
|
sampling period."
|
|
::= { a3ComSysSmtFddiMacRateEntry 7 }
|
|
|
|
a3ComSysSmtFddiMacRatePeakByteTransmitRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The peak value of a3ComSysSmtFddiMacByteTransmitRate since the
|
|
system was last initialized for the FDDI MAC identified by
|
|
this entry."
|
|
::= { a3ComSysSmtFddiMacRateEntry 8 }
|
|
|
|
a3ComSysSmtFddiMacRateFrameTransmitRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The average number of frames transmitted per second by
|
|
the FDDI MAC identified by this entry during the most
|
|
recent sampling period."
|
|
::= { a3ComSysSmtFddiMacRateEntry 9 }
|
|
|
|
a3ComSysSmtFddiMacRatePeakFrameTransmitRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The peak value of a3ComSysSmtFddiMacFrameTransmitRate since the
|
|
system was last initialized for the FDDI MAC identified by
|
|
this entry."
|
|
::= { a3ComSysSmtFddiMacRateEntry 10 }
|
|
|
|
-- The Switching Systems MIB SMT FDDI port table.
|
|
|
|
a3ComSysSmtFddiPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysSmtFddiPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of FDDI port entries. A single entry exists in
|
|
this list for each FDDI port managed by this agent."
|
|
::= { a3ComSysSmt 6 }
|
|
|
|
a3ComSysSmtFddiPortEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysSmtFddiPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An FDDI port entry contains information about a particular
|
|
FDDI port managed by this agent."
|
|
INDEX { a3ComSysSmtFddiPortSmtIndex,
|
|
a3ComSysSmtFddiPortIndex }
|
|
::= { a3ComSysSmtFddiPortTable 1 }
|
|
|
|
A3ComSysSmtFddiPortEntry ::=
|
|
SEQUENCE {
|
|
a3ComSysSmtFddiPortSmtIndex
|
|
INTEGER,
|
|
a3ComSysSmtFddiPortIndex
|
|
INTEGER,
|
|
a3ComSysSmtFddiPortLocationType
|
|
INTEGER,
|
|
a3ComSysSmtFddiPortLocationTypeIndex
|
|
INTEGER,
|
|
a3ComSysSmtFddiPortLocationLocalIndex
|
|
INTEGER,
|
|
a3ComSysSmtFddiPortLabel
|
|
DisplayString
|
|
}
|
|
|
|
a3ComSysSmtFddiPortSmtIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the SMT instance identified by this entry,
|
|
relative to this agent."
|
|
::= { a3ComSysSmtFddiPortEntry 1 }
|
|
|
|
a3ComSysSmtFddiPortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the FDDI port identified by this entry,
|
|
within the SMT identified by this entry."
|
|
::= { a3ComSysSmtFddiPortEntry 2 }
|
|
|
|
a3ComSysSmtFddiPortLocationType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
modularSlot(2),
|
|
chassis(3),
|
|
modularCard(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of location where the FDDI port identified by
|
|
this entry is physically located."
|
|
::= { a3ComSysSmtFddiPortEntry 3 }
|
|
|
|
a3ComSysSmtFddiPortLocationTypeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the location identified by the corresponding
|
|
instance of a3ComSysSmtFddiPortLocationType where the FDDI port
|
|
identified by this entry is physically located."
|
|
::= { a3ComSysSmtFddiPortEntry 4 }
|
|
|
|
a3ComSysSmtFddiPortLocationLocalIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The local index of the FDDI port identified by this
|
|
entry relative to the location specified by the
|
|
corresponding values of a3ComSysSmtFddiPortLocationType and
|
|
a3ComSysSmtFddiPortLocationTypeIndex."
|
|
::= { a3ComSysSmtFddiPortEntry 5 }
|
|
|
|
a3ComSysSmtFddiPortLabel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ASCII text string describing the FDDI port identified
|
|
by this entry."
|
|
::= { a3ComSysSmtFddiPortEntry 6 }
|
|
|
|
a3ComSysSmtFddiMacLocationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysSmtFddiMacLocationEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An FDDI MAC Location table contains information to assign
|
|
an FDDI MAC to a different Location. The system must be
|
|
rebooted after all changes to this table are completed
|
|
in order that the changes take effect."
|
|
::= { a3ComSysSmt 7 }
|
|
|
|
a3ComSysSmtFddiMacLocationEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysSmtFddiMacLocationEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An FDDI MAC entry contains information to assign
|
|
an FDDI MAC to a different Location."
|
|
INDEX { a3ComSysSmtFddiMacLocationSmtIndex,
|
|
a3ComSysSmtFddiMacLocationIndex }
|
|
::= { a3ComSysSmtFddiMacLocationTable 1 }
|
|
|
|
A3ComSysSmtFddiMacLocationEntry ::=
|
|
SEQUENCE {
|
|
a3ComSysSmtFddiMacLocationSmtIndex INTEGER,
|
|
a3ComSysSmtFddiMacLocationIndex INTEGER,
|
|
a3ComSysSmtFddiMacCurrentLocation INTEGER,
|
|
a3ComSysSmtFddiMacRequestedLocation INTEGER,
|
|
a3ComSysSmtFddiMacAvailableLocation INTEGER
|
|
}
|
|
|
|
a3ComSysSmtFddiMacLocationSmtIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the SMT instance identified by this entry,
|
|
relative to the agent."
|
|
::= { a3ComSysSmtFddiMacLocationEntry 1 }
|
|
|
|
a3ComSysSmtFddiMacLocationIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the FDDI MAC instance identified by this entry,
|
|
relative to the SMT identified by this entry."
|
|
::= { a3ComSysSmtFddiMacLocationEntry 2 }
|
|
|
|
a3ComSysSmtFddiMacCurrentLocation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
internalBackplane(1),
|
|
externalFddiPort(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the MAC identified by this entry is assigned
|
|
to a backplane FDDI station (internal) or an FDDI station
|
|
configured on a module (external.)"
|
|
::= { a3ComSysSmtFddiMacLocationEntry 3 }
|
|
|
|
a3ComSysSmtFddiMacRequestedLocation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
internalBackplane(1),
|
|
externalFddiPort(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Location which the MAC identified by this entry is to
|
|
be assigned to during the next reboot."
|
|
::= { a3ComSysSmtFddiMacLocationEntry 4 }
|
|
|
|
a3ComSysSmtFddiMacAvailableLocation OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
internalBackplane(1),
|
|
externalFddiPort(2),
|
|
internalOrExternal(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the Location(s) available for this MAC. A mac Location
|
|
which can be modified to either the interanl backplane or an
|
|
external FDDI port is indicated by internalOrExternal(3)."
|
|
::= { a3ComSysSmtFddiMacLocationEntry 5 }
|
|
|
|
a3ComSysSmtFddiMacStationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysSmtFddiMacStationEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An FDDI station MAC table contains information to assign
|
|
an FDDI MAC to an FDDI Station. The system must be
|
|
rebooted after all changes to this table are completed
|
|
in order that the changes take effect."
|
|
::= { a3ComSysSmt 8 }
|
|
|
|
a3ComSysSmtFddiMacStationEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysSmtFddiMacStationEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An FDDI MAC entry contains information to assign
|
|
an FDDI MAC to an FDDI Station."
|
|
INDEX { a3ComSysSmtFddiMacStationSmtIndex,
|
|
a3ComSysSmtFddiMacStationIndex }
|
|
::= { a3ComSysSmtFddiMacStationTable 1 }
|
|
|
|
A3ComSysSmtFddiMacStationEntry ::=
|
|
SEQUENCE {
|
|
a3ComSysSmtFddiMacStationSmtIndex INTEGER,
|
|
a3ComSysSmtFddiMacStationIndex INTEGER,
|
|
a3ComSysSmtFddiMacCurrentStation INTEGER,
|
|
a3ComSysSmtFddiMacRequestedStation INTEGER,
|
|
a3ComSysSmtFddiMacAvailableStations INTEGER
|
|
}
|
|
|
|
a3ComSysSmtFddiMacStationSmtIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the SMT instance identified by this entry,
|
|
relative to this agent."
|
|
::= { a3ComSysSmtFddiMacStationEntry 1 }
|
|
|
|
a3ComSysSmtFddiMacStationIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the MAC instance identified by this entry,
|
|
relative to the SMT identified by this entry."
|
|
::= { a3ComSysSmtFddiMacStationEntry 2 }
|
|
|
|
a3ComSysSmtFddiMacCurrentStation OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates which FDDI station that the FDDI MAC identified
|
|
by this entry is assigned to. A value of 0 indicates
|
|
that the mac is assigned to an external station. Otherwise
|
|
the value represents the internal backplane station number."
|
|
::= { a3ComSysSmtFddiMacStationEntry 3 }
|
|
|
|
a3ComSysSmtFddiMacRequestedStation OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates which FDDI station the FDDI MAC identified
|
|
by this entry will be set to during the next system reboot.
|
|
A value of 0 indicates an external station. Otherwise the
|
|
value represents the internal backplane station number."
|
|
::= { a3ComSysSmtFddiMacStationEntry 4 }
|
|
|
|
a3ComSysSmtFddiMacAvailableStations OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value is a sum. Setting of the first bit (LSB)
|
|
indicates that the MAC can be assigned to an external
|
|
station. Available backplane stations are indicated
|
|
by adding 2^StationNumber to the sum. Where StationNumber
|
|
represents a backplane station number."
|
|
::= { a3ComSysSmtFddiMacStationEntry 5 }
|
|
|
|
a3ComSysSmtFddiPortStationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysSmtFddiPortStationEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An FDDI station Port table contains information to assign
|
|
an FDDI Port to an FDDI Station. The system must be
|
|
rebooted after all changes to this table are completed
|
|
in order that the changes take effect."
|
|
::= { a3ComSysSmt 9 }
|
|
|
|
a3ComSysSmtFddiPortStationEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysSmtFddiPortStationEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An FDDI Port entry contains information to assign
|
|
an FDDI Port to an FDDI Station."
|
|
INDEX { a3ComSysSmtFddiPortStationSmtIndex,
|
|
a3ComSysSmtFddiPortStationIndex }
|
|
::= { a3ComSysSmtFddiPortStationTable 1 }
|
|
|
|
A3ComSysSmtFddiPortStationEntry ::=
|
|
SEQUENCE {
|
|
a3ComSysSmtFddiPortStationSmtIndex INTEGER,
|
|
a3ComSysSmtFddiPortStationIndex INTEGER,
|
|
a3ComSysSmtFddiPortCurrentStation INTEGER,
|
|
a3ComSysSmtFddiPortRequestedStation INTEGER,
|
|
a3ComSysSmtFddiPortAvailableStations INTEGER
|
|
}
|
|
|
|
a3ComSysSmtFddiPortStationSmtIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the SMT instance identified by this entry,
|
|
relative to this agent."
|
|
::= { a3ComSysSmtFddiPortStationEntry 1 }
|
|
|
|
a3ComSysSmtFddiPortStationIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the Port instance identified by this entry,
|
|
relative to the SMT indentified by this entry."
|
|
::= { a3ComSysSmtFddiPortStationEntry 2 }
|
|
|
|
a3ComSysSmtFddiPortCurrentStation OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates which FDDI station the FDDI Port identified
|
|
by this entry is assigned to. A value of 0 indicates
|
|
that the Port is assigned to an external station. Otherwise
|
|
the value represents the internal backplane station number."
|
|
::= { a3ComSysSmtFddiPortStationEntry 3 }
|
|
|
|
a3ComSysSmtFddiPortRequestedStation OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates which FDDI station the FDDI port identified
|
|
by this entry will be set to during the next system reboot.
|
|
A value of 0 indicates an external station. Otherwise the
|
|
value represents the internal backplane station number."
|
|
::= { a3ComSysSmtFddiPortStationEntry 4 }
|
|
|
|
a3ComSysSmtFddiPortAvailableStations OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value is a sum. Setting of the first bit
|
|
indicates that the port can be assigned to an external
|
|
station. Available backplane stations are indicated
|
|
by adding 2^StationNumber to the sum. Where StationNumber
|
|
represents a backplane station number."
|
|
::= { a3ComSysSmtFddiPortStationEntry 5 }
|
|
|
|
|
|
|
|
-- The Switching Systems MIB bridge group. Implementation of this group
|
|
-- is mandatory for agents which manage bridge resources.
|
|
|
|
a3ComSysBridgeCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The count of bridges managed by this agent."
|
|
::= { a3ComSysBridge 1 }
|
|
|
|
-- The Switching Systems MIB bridge table.
|
|
|
|
a3ComSysBridgeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysBridgeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of bridge entries. A single entry exists in this
|
|
list for each bridge managed by this agent."
|
|
::= { a3ComSysBridge 2 }
|
|
|
|
a3ComSysBridgeEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysBridgeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A bridge entry contains information about a particular
|
|
bridge managed by this agent."
|
|
INDEX { a3ComSysBridgeIndex }
|
|
::= { a3ComSysBridgeTable 1 }
|
|
|
|
A3ComSysBridgeEntry ::=
|
|
SEQUENCE {
|
|
a3ComSysBridgeIndex
|
|
INTEGER,
|
|
a3ComSysBridgePortCount
|
|
INTEGER,
|
|
a3ComSysBridgeAddressTableSize
|
|
INTEGER,
|
|
a3ComSysBridgeAddressTableCount
|
|
INTEGER,
|
|
a3ComSysBridgeAddressTablePeakCount
|
|
INTEGER,
|
|
a3ComSysBridgeAddressThreshold
|
|
INTEGER,
|
|
a3ComSysBridgeMode
|
|
INTEGER,
|
|
a3ComSysBridgeBackbonePort
|
|
INTEGER,
|
|
a3ComSysBridgeIpFragmentationEnabled
|
|
INTEGER,
|
|
a3ComSysBridgeTrFddiTranslationMode
|
|
INTEGER,
|
|
a3ComSysBridgeSTPGroupAddress
|
|
OCTET STRING,
|
|
a3ComSysBridgeSTPEnable
|
|
INTEGER,
|
|
a3ComSysBridgeIpxSnapTranslationEnable
|
|
INTEGER,
|
|
a3ComSysBridgeLowLatencyEnable
|
|
INTEGER,
|
|
a3ComSysBridgeVlanMode
|
|
INTEGER
|
|
}
|
|
|
|
|
|
a3ComSysBridgeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the bridge identified by this entry,
|
|
relative to this agent."
|
|
::= { a3ComSysBridgeEntry 1 }
|
|
|
|
a3ComSysBridgePortCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of bridge ports that the bridge identified by
|
|
this entry controls."
|
|
::= { a3ComSysBridgeEntry 2 }
|
|
|
|
a3ComSysBridgeAddressTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the address table for the bridge identified
|
|
by this entry."
|
|
::= { a3ComSysBridgeEntry 3 }
|
|
|
|
a3ComSysBridgeAddressTableCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current count of addresses in the address table for
|
|
the bridge identified by this entry."
|
|
::= { a3ComSysBridgeEntry 4 }
|
|
|
|
a3ComSysBridgeAddressTablePeakCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The peak count of addresses in the address table for the
|
|
bridge identified by this entry, since the system was last
|
|
initialized."
|
|
::= { a3ComSysBridgeEntry 5 }
|
|
|
|
a3ComSysBridgeAddressThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A reporting threshold for the total number of addresses
|
|
known for the bridge identified by this entry. When this
|
|
threshold is reached, the event
|
|
a3ComSysBridgeAddressThresholdEvent is generated. The range of
|
|
valid values for setting this object is between 1 and the
|
|
corresponding value reported by a3ComSysBridgeAddressTableSize
|
|
+ 1 (Note that this range applies to values issued in set
|
|
requests. The current value may be outside this range,
|
|
for example if the corresponding value of a3ComSysBridgeMode is
|
|
changed). Setting this object to one greater than the
|
|
address table size disables the generation of
|
|
a3ComSysBridgeAddressThresholdEvents since the limit will never
|
|
be reached."
|
|
::= { a3ComSysBridgeEntry 6 }
|
|
|
|
a3ComSysBridgeMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
expressMode(1),
|
|
ieee8021dBridgeMode(2),
|
|
notSupported(3),
|
|
ieee8021dSRTBridgeMode(4),
|
|
ieee8021dSRBridgeMode(5),
|
|
ibmSRBridgeMode(6),
|
|
srtBBridgeMode(7),
|
|
srExpressBridgeMode(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The operational mode of the bridge identified by this
|
|
entry. Note that bridges which report notSupported(3)
|
|
will not support sets of this object, and that the value
|
|
notSupported(3) is not a valid value for a set operation."
|
|
::= { a3ComSysBridgeEntry 7 }
|
|
|
|
a3ComSysBridgeBackbonePort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of the port selected as the backbone segment
|
|
port when the corresponding value of a3ComSysBridgeMode is
|
|
is expressMode(1). The value of this object can range
|
|
from 1 to the corresponding value of a3ComSysBridgePortCount,
|
|
however, some bridges may support only a subset of ports
|
|
as backbone ports. If the corresponding value of
|
|
a3ComSysBridgeMode is not expressMode(1), the value of this
|
|
object is ignored."
|
|
::= { a3ComSysBridgeEntry 8 }
|
|
|
|
a3ComSysBridgeIpFragmentationEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
true(1),
|
|
false(2),
|
|
notSupported(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A flag indicating whether or not IP fragmentation is
|
|
enabled on this bridge. Note that bridges which report
|
|
notSupported(3) will not support sets of this object, and
|
|
that the value notSupported(3) is not a valid value for a
|
|
set operation."
|
|
::= { a3ComSysBridgeEntry 9 }
|
|
|
|
a3ComSysBridgeTrFddiTranslationMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
native(1),
|
|
backbone(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The mode used to describe whether the embedded MAC
|
|
addresses are byte-conjugated in order to convert them
|
|
from Token Ring format to native FDDI format (and vice
|
|
versa), or whether they are left alone (used for traffic
|
|
flowing across a FDDI backbone to/from Token Ring end
|
|
stations)."
|
|
::= { a3ComSysBridgeEntry 10 }
|
|
|
|
a3ComSysBridgeSTPGroupAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (6)) -- 6 octet address in "canonical" order
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Spanning tree bridge group address. The address cannot be
|
|
changed if the spanning tree is enabled (a3ComSysBridgeStpEnabled)."
|
|
::= { a3ComSysBridgeEntry 11 }
|
|
|
|
a3ComSysBridgeSTPEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
true(1),
|
|
false(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object indicates if spanning tree bridge feature is
|
|
enabled or disabled. If enabled this value will equal true(1)."
|
|
::= { a3ComSysBridgeEntry 12 }
|
|
|
|
a3ComSysBridgeIpxSnapTranslationEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
true(1),
|
|
false(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object indicates if the IPX 802.3-FDDI SNAP Translation
|
|
bridge feature is enabled or disabled. If enabled this
|
|
value will equal true(1). Note, this object may not be
|
|
supported on all bridges."
|
|
::= { a3ComSysBridgeEntry 13 }
|
|
|
|
a3ComSysBridgeLowLatencyEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
true(1),
|
|
false(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object indicates if the bridge low latency
|
|
feature is enabled or disabled. If enabled this
|
|
value will equal true(1). Note, this object may not be
|
|
supported on all bridges."
|
|
::= { a3ComSysBridgeEntry 14 }
|
|
|
|
a3ComSysBridgeVlanMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open(1),
|
|
closed(2),
|
|
mixed(3),
|
|
notSupported(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object indicates the VLAN types that this
|
|
bridge will support. Open mode means that each VLAN
|
|
within this bridge will be of the Open type; all VLANs
|
|
within this bridge will share the same address table.
|
|
Closed mode means that each VLAN within this bridge
|
|
will be of the Closed type; each VLAN within this
|
|
bridge will have its own address table. Mixed mode
|
|
means that each VLAN within this bridge with be of
|
|
either the Open or Closed type; all Open VLANs will
|
|
share the same address table and each Closed VLAN
|
|
will have its own address table."
|
|
::= { a3ComSysBridgeEntry 15 }
|
|
|
|
-- The Switching Systems MIB bridge port table.
|
|
|
|
a3ComSysBridgePortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysBridgePortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of bridge port entries. A single entry exists in
|
|
this list for each bridge port managed by this agent."
|
|
::= { a3ComSysBridge 3 }
|
|
|
|
a3ComSysBridgePortEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysBridgePortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A bridge port entry contains information about a
|
|
particular bridge port managed by this agent."
|
|
INDEX { a3ComSysBridgePortBridgeIndex,
|
|
a3ComSysBridgePortIndex }
|
|
::= { a3ComSysBridgePortTable 1 }
|
|
|
|
A3ComSysBridgePortEntry ::=
|
|
SEQUENCE {
|
|
a3ComSysBridgePortBridgeIndex
|
|
INTEGER,
|
|
a3ComSysBridgePortIndex
|
|
INTEGER,
|
|
a3ComSysBridgePortIfIndex
|
|
INTEGER,
|
|
a3ComSysBridgePortReceiveMulticastLimit
|
|
INTEGER,
|
|
a3ComSysBridgePortAddressAction
|
|
INTEGER,
|
|
a3ComSysBridgePortSpanningTreeFrameReceivedCounts
|
|
Counter,
|
|
a3ComSysBridgePortReceiveBlockedDiscards
|
|
Counter,
|
|
a3ComSysBridgePortReceiveMulticastLimitExceededs
|
|
Counter,
|
|
a3ComSysBridgePortReceiveMulticastLimitExceededDiscards
|
|
Counter,
|
|
a3ComSysBridgePortReceiveSecurityDiscards
|
|
Counter,
|
|
a3ComSysBridgePortReceiveUnknownDiscards
|
|
Counter,
|
|
a3ComSysBridgePortReceiveOtherDiscards
|
|
Counter,
|
|
a3ComSysBridgePortReceiveErrorDiscards
|
|
Counter,
|
|
a3ComSysBridgePortSameSegmentDiscards
|
|
Counter,
|
|
a3ComSysBridgePortTransmitBlockedDiscards
|
|
Counter,
|
|
a3ComSysBridgePortReceiveAllPathFilteredFrames
|
|
Counter,
|
|
a3ComSysBridgePortReceiveMulticastPathFilteredFrames
|
|
Counter,
|
|
a3ComSysBridgePortTransmitAllPathFilteredFrames
|
|
Counter,
|
|
a3ComSysBridgePortTransmitMulticastPathFilteredFrames
|
|
Counter,
|
|
a3ComSysBridgePortForwardedUnicastFrames
|
|
Counter,
|
|
a3ComSysBridgePortForwardedUnicastOctets
|
|
Counter,
|
|
a3ComSysBridgePortForwardedMulticastFrames
|
|
Counter,
|
|
a3ComSysBridgePortForwardedMulticastOctets
|
|
Counter,
|
|
a3ComSysBridgePortFloodedUnicastFrames
|
|
Counter,
|
|
a3ComSysBridgePortFloodedUnicastOctets
|
|
Counter,
|
|
a3ComSysBridgePortStpMode
|
|
INTEGER,
|
|
a3ComSysBridgePortReceiveMulticastLimitFrameType
|
|
INTEGER,
|
|
a3ComSysBridgePortForwardedFrames
|
|
Counter,
|
|
a3ComSysBridgePortReceiveMulticastLimitMultiplier
|
|
INTEGER
|
|
}
|
|
|
|
a3ComSysBridgePortBridgeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the bridge identified by this entry,
|
|
relative to this agent."
|
|
::= { a3ComSysBridgePortEntry 1 }
|
|
|
|
a3ComSysBridgePortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the bridge port identified by this entry,
|
|
within the bridge identified by this entry."
|
|
::= { a3ComSysBridgePortEntry 2 }
|
|
|
|
a3ComSysBridgePortIfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the MIB-II ifIndex corresponding to the
|
|
bridge port identified by this entry."
|
|
::= { a3ComSysBridgePortEntry 3 }
|
|
|
|
a3ComSysBridgePortReceiveMulticastLimit OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable limits the number of multicast frames forwarded
|
|
by this port over a 1 second interval. The minimum threshold
|
|
limit may vary between platforms, but can be determined by multiplying
|
|
this value by the a3ComSysBridgePortReceiveMulticastLimitMultiplier
|
|
value. For example if this value equals 2, and the
|
|
a3ComSysBridgePortReceiveMulticastLimitMultiplier equals 1000 then no
|
|
more than 2000 multicast frames per second will be forwarded by this port.
|
|
|
|
The default value for this object is zero which an infinite rate."
|
|
::= { a3ComSysBridgePortEntry 4 }
|
|
|
|
a3ComSysBridgePortAddressAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
freezeAddress(2),
|
|
flushAddress(3),
|
|
flushDynamicAddress(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object, when read, always returns the value
|
|
other(1). The behavior of setting this object to each of
|
|
the acceptable values is as follows:
|
|
|
|
freezeAddress: causes all the learned dynamic
|
|
addresses to be converted into static
|
|
addresses.
|
|
|
|
flushAddress: causes all the addresses to be flushed
|
|
from the address list for the bridge
|
|
port identified by this entry.
|
|
|
|
flushDynamicAddress:
|
|
causes all dynamic addresses to be
|
|
flushed from the address list for the
|
|
bridge port identified by this entry."
|
|
::= { a3ComSysBridgePortEntry 5 }
|
|
|
|
a3ComSysBridgePortSpanningTreeFrameReceivedCounts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of spanning tree frames received by the
|
|
bridge port identified by this entry."
|
|
::= { a3ComSysBridgePortEntry 6 }
|
|
|
|
a3ComSysBridgePortReceiveBlockedDiscards OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of frames discarded by the bridge port
|
|
identified by this entry because the receiving bridge port
|
|
was not in the 'forwarding' state."
|
|
::= { a3ComSysBridgePortEntry 7 }
|
|
|
|
a3ComSysBridgePortReceiveMulticastLimitExceededs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of times the value of
|
|
a3ComSysBridgePortReceiveMulticastLimit was exceeded for the
|
|
port identified by this entry."
|
|
::= { a3ComSysBridgePortEntry 8 }
|
|
|
|
a3ComSysBridgePortReceiveMulticastLimitExceededDiscards OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of multicast/broadcast frames discarded by the
|
|
bridge port identified by this entry because the
|
|
corresponding value of a3ComSysBridgePortReceiveMulticastLimit
|
|
was exceeded."
|
|
::= { a3ComSysBridgePortEntry 9 }
|
|
|
|
a3ComSysBridgePortReceiveSecurityDiscards OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of frames discarded by the bridge port
|
|
identified by this entry because they contained source
|
|
addresses which were statically configured on another
|
|
bridge port. A statically configured address (station),
|
|
which is not allowed to move, appears to have moved."
|
|
::= { a3ComSysBridgePortEntry 10 }
|
|
|
|
a3ComSysBridgePortReceiveUnknownDiscards OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of frames discarded by the bridge port
|
|
identified by this entry because the destination address
|
|
was unknown. Note that this counter is only valid for
|
|
backbone ports, and only when the bridge is operating in
|
|
express mode."
|
|
::= { a3ComSysBridgePortEntry 11 }
|
|
|
|
a3ComSysBridgePortReceiveOtherDiscards OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of frames discarded by the bridge port
|
|
identified by this entry because they contained either
|
|
invalid (group) source addresses or source addresses
|
|
belonging to this bridge (indicative of network loops)."
|
|
::= { a3ComSysBridgePortEntry 12 }
|
|
|
|
a3ComSysBridgePortReceiveErrorDiscards OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of frames discarded by the bridge port
|
|
identified by this entry because of internal bridge system
|
|
errors (e.g., hardware and software address table
|
|
discrepencies)."
|
|
::= { a3ComSysBridgePortEntry 13 }
|
|
|
|
a3ComSysBridgePortSameSegmentDiscards OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of frames discarded by the bridge port
|
|
identified by this entry because the destination address
|
|
is known on the same network segment as the source address,
|
|
i.e., the frame does not need to be bridged."
|
|
::= { a3ComSysBridgePortEntry 14 }
|
|
|
|
a3ComSysBridgePortTransmitBlockedDiscards OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of frames discarded by the bridge port
|
|
identified by this entry because the transmitting bridge
|
|
port was not in the 'forwarding' state."
|
|
::= { a3ComSysBridgePortEntry 15 }
|
|
|
|
a3ComSysBridgePortReceiveAllPathFilteredFrames OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of frames discarded by the bridge port
|
|
identified by this entry due to user defined receive all
|
|
path filters."
|
|
::= { a3ComSysBridgePortEntry 16 }
|
|
|
|
a3ComSysBridgePortReceiveMulticastPathFilteredFrames OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of frames discarded by the bridge port
|
|
identified by this entry due to user defined receive
|
|
multicast path filters."
|
|
::= { a3ComSysBridgePortEntry 17 }
|
|
|
|
a3ComSysBridgePortTransmitAllPathFilteredFrames OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of frames discarded by the bridge port
|
|
identified by this entry due to user defined transmit all
|
|
path filters."
|
|
::= { a3ComSysBridgePortEntry 18 }
|
|
|
|
a3ComSysBridgePortTransmitMulticastPathFilteredFrames OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of frames discarded by the bridge port
|
|
identified by this entry due to user defined transmit
|
|
multicast path filters."
|
|
::= { a3ComSysBridgePortEntry 19 }
|
|
|
|
a3ComSysBridgePortForwardedUnicastFrames OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of unicast frames which this port forwarded
|
|
to a single destination port."
|
|
::= { a3ComSysBridgePortEntry 20 }
|
|
|
|
a3ComSysBridgePortForwardedUnicastOctets OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of octets contained in unicast frames
|
|
which this port forwarded to a single destination port."
|
|
::= { a3ComSysBridgePortEntry 21 }
|
|
|
|
a3ComSysBridgePortForwardedMulticastFrames OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of multicast frames which this port forwarded."
|
|
::= { a3ComSysBridgePortEntry 22 }
|
|
|
|
a3ComSysBridgePortForwardedMulticastOctets OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of octets contained in multicast frames which
|
|
this port forwarded."
|
|
::= { a3ComSysBridgePortEntry 23 }
|
|
|
|
a3ComSysBridgePortFloodedUnicastFrames OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of unicast frames which this port flooded to
|
|
all other ports in the bridge."
|
|
::= { a3ComSysBridgePortEntry 24 }
|
|
|
|
a3ComSysBridgePortFloodedUnicastOctets OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of octets contained in unicast frames which
|
|
this port flooded to all other ports in the bridge."
|
|
::= { a3ComSysBridgePortEntry 25 }
|
|
|
|
|
|
a3ComSysBridgePortStpMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2),
|
|
remove(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The mode of the bridge port."
|
|
REFERENCE
|
|
"IEEE 802.1D-1990: Section 4.5.5.2 for enable and disable modes."
|
|
::= { a3ComSysBridgePortEntry 26 }
|
|
|
|
a3ComSysBridgePortReceiveMulticastLimitFrameType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
broadcastAndMulticast(1),
|
|
broadcastOnly(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object identifies the frames type(s) that are to be
|
|
counted when determining if the receive multicast limit
|
|
has been exceeded for this bridge port. Devices attached
|
|
to networks with predominantly high multicast traffic
|
|
(e.g. video) should set this value to broadcastOnly(2)
|
|
to detect broadcast storms."
|
|
::= { a3ComSysBridgePortEntry 27 }
|
|
|
|
a3ComSysBridgePortForwardedFrames OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of frames which this port forwarded."
|
|
::= { a3ComSysBridgePortEntry 28 }
|
|
|
|
|
|
a3ComSysBridgePortReceiveMulticastLimitMultiplier OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable determines the minimum setting for the multicast
|
|
limit threshold. For example if this value equals 1000, and the
|
|
a3ComSysBridgePortReceiveMulticastLimit variable equals 2 then
|
|
no more than 2000 multicast frames per second will be forwarded
|
|
by this port."
|
|
::= { a3ComSysBridgePortEntry 29 }
|
|
|
|
|
|
|
|
-- ::= { a3ComSysBridge 4 } Reserved. Do not use.
|
|
|
|
|
|
-- The Switching Systems MIB bridge port address table
|
|
|
|
a3ComSysBridgePortAddressTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysBridgePortAddressEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of bridge port address information. A single
|
|
entry exists in this list for each learned address,
|
|
accross all bridge ports and all bridges managed by this
|
|
agent."
|
|
::= { a3ComSysBridge 5 }
|
|
|
|
a3ComSysBridgePortAddressEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysBridgePortAddressEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An bridge port address entry contains information about a
|
|
particular bridge port address. To create a new entry,
|
|
set an instance of a3ComSysBridgePortAddressRemoteAddress with
|
|
the address index portion of the instance set to 0, to a
|
|
valid value. To remove an entry, set the instance of the
|
|
a3ComSysBridgePortAddressType for the entry to invalid(2)."
|
|
INDEX { a3ComSysBridgePortAddressBridgeIndex,
|
|
a3ComSysBridgePortAddressPortIndex,
|
|
a3ComSysBridgePortAddressIndex }
|
|
::= { a3ComSysBridgePortAddressTable 1 }
|
|
|
|
A3ComSysBridgePortAddressEntry ::=
|
|
SEQUENCE {
|
|
a3ComSysBridgePortAddressBridgeIndex
|
|
INTEGER,
|
|
a3ComSysBridgePortAddressPortIndex
|
|
INTEGER,
|
|
a3ComSysBridgePortAddressIndex
|
|
INTEGER,
|
|
a3ComSysBridgePortAddressRemoteAddress
|
|
OCTET STRING,
|
|
a3ComSysBridgePortAddressType
|
|
INTEGER,
|
|
a3ComSysBridgePortAddressIsStatic
|
|
INTEGER,
|
|
a3ComSysBridgePortAddressStaticPort
|
|
INTEGER,
|
|
a3ComSysBridgePortAddressAge
|
|
INTEGER
|
|
}
|
|
|
|
a3ComSysBridgePortAddressBridgeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the bridge identified by this entry,
|
|
relative to this agent."
|
|
::= { a3ComSysBridgePortAddressEntry 1 }
|
|
|
|
a3ComSysBridgePortAddressPortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the bridge port identified by this entry,
|
|
within the bridge identified by this entry."
|
|
::= { a3ComSysBridgePortAddressEntry 2 }
|
|
|
|
a3ComSysBridgePortAddressIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of this address entry within the bridge address
|
|
table for the bridge identified by this entry. This index
|
|
ranges from 1 to the corresponding value of
|
|
a3ComSysBridgeAddressTableSize."
|
|
::= { a3ComSysBridgePortAddressEntry 3 }
|
|
|
|
a3ComSysBridgePortAddressRemoteAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (6)) -- 6 octet address in "canonical" order
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The remote MAC address detected on the bridge port
|
|
identified by to this entry. Setting this object results
|
|
in an attempt to create a new entry in the table. Since
|
|
the value of a3ComSysBridgePortAddressIndex is determined
|
|
automatically internal to the bridge, a set is only
|
|
successful if the index value specified for
|
|
a3ComSysBridgePortAddressIndex is zero. A get-next
|
|
using the values of a3ComSysBridgePortAddressTypeIndex and
|
|
a3ComSysBridgePortAddressPortIndex can be used to determine the
|
|
address index assigned to the newly added address entry."
|
|
::= { a3ComSysBridgePortAddressEntry 4 }
|
|
|
|
a3ComSysBridgePortAddressType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
valid(1),
|
|
invalid(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object, when read, always returns the value valid(1).
|
|
Setting this object to invalid(2) will remove the
|
|
corresponding address entry from the table."
|
|
::= { a3ComSysBridgePortAddressEntry 5 }
|
|
|
|
a3ComSysBridgePortAddressIsStatic OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
isStatic(1),
|
|
isDynamic(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A value indicating whether this MAC address was
|
|
statically configured or was dynamically learned. Note
|
|
that isStatic(1) it the only valid for set operations."
|
|
::= { a3ComSysBridgePortAddressEntry 6 }
|
|
|
|
a3ComSysBridgePortAddressStaticPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the corresponding value of the object
|
|
a3ComSysBridgePortAddressIsStatic is isStatic(1), this object
|
|
indicates the local bridge port index (as reported by
|
|
a3ComSysBridgePortLocalIndex) for which this address MAC was
|
|
statically configured. If the object
|
|
a3ComSysBridgePortAddressIsStatic has the value isDynamic(2),
|
|
the value of this object is 0."
|
|
::= { a3ComSysBridgePortAddressEntry 7 }
|
|
|
|
a3ComSysBridgePortAddressAge OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object indicates the time, in seconds, elapsed since
|
|
a packet containing this address as a source was last seen
|
|
on the bridge port identified by this entry."
|
|
::= { a3ComSysBridgePortAddressEntry 8 }
|
|
|
|
a3ComSysBridgeStpGroupAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (6)) -- 6 octet address in "canonical" order
|
|
ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Spanning tree bridge group address. The address cannot be
|
|
changed if the spanning tree is enabled (a3ComSysBridgeStpEnabled).
|
|
This object can now be found under the a3ComSysBridgeTable
|
|
as a3ComSysBridgeSTPGroupAddress."
|
|
::= { a3ComSysBridge 6 }
|
|
|
|
a3ComSysBridgeStpEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
true(1),
|
|
false(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"This object indicates if spanning tree bridge feature is
|
|
enabled or disabled. If enabled this value will equal true(1).
|
|
This object can now be found under the a3ComSysBridgeTable
|
|
as a3ComSysBridgeSTPEnable."
|
|
::= { a3ComSysBridge 7 }
|
|
|
|
-- The Switching Systems MIB IP router group. Implementation of this
|
|
-- group is mandatory for agents which manage IP router resources.
|
|
-- This group is reserved for future use.
|
|
|
|
-- The Switching Systems MIB networking monitoring group. Implementation
|
|
-- of this group is manadatory for all agents which manage bridge
|
|
-- resources that support network monitoring.
|
|
|
|
-- The Switching Systems MIB network analyzer table.
|
|
|
|
a3ComSysNetworkAnalyzerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysNetworkAnalyzerTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of analyzer entries. A single entry exists in this
|
|
list for each bridge port configured for an analyzer."
|
|
::= { a3ComSysNetworkMonitor 1 }
|
|
|
|
a3ComSysNetworkAnalyzerTableEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysNetworkAnalyzerTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An analyzer table entry contains information relating an
|
|
analyzer port address to the bridge and port index for that
|
|
analyzer.
|
|
|
|
The effect of creating an entry for a particular port is
|
|
to configure that port for monitoring. A port which is
|
|
configured for monitoring is no longer available for
|
|
switching. To create an entry, set the value of the
|
|
a3ComSysNetworkAnalyzerStatus object for a non-existent instance
|
|
to valid(1). The value of the a3ComSysNetworkAnalyzerPhysicalAddress
|
|
object for the new entry is filled in as a result of the
|
|
creation.
|
|
|
|
The effect of removing an entry for a particular port is to
|
|
disable the port for monitoring. The port is then available
|
|
for switching. To remove an entry, set the value of the
|
|
corresponding instance of the a3ComSysNetworkAnalyzerStatus object
|
|
to invalid(2)."
|
|
INDEX { a3ComSysNetworkAnalyzerBridgeIndex,
|
|
a3ComSysNetworkAnalyzerBridgePortIndex}
|
|
::= { a3ComSysNetworkAnalyzerTable 1 }
|
|
|
|
A3ComSysNetworkAnalyzerTableEntry ::=
|
|
SEQUENCE {
|
|
a3ComSysNetworkAnalyzerBridgeIndex
|
|
INTEGER,
|
|
a3ComSysNetworkAnalyzerBridgePortIndex
|
|
INTEGER,
|
|
a3ComSysNetworkAnalyzerPhysicalAddress
|
|
OCTET STRING,
|
|
a3ComSysNetworkAnalyzerStatus
|
|
INTEGER
|
|
}
|
|
|
|
a3ComSysNetworkAnalyzerBridgeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the bridge relative to this agent where the
|
|
analyzer identified by this entry is configured."
|
|
::= { a3ComSysNetworkAnalyzerTableEntry 1 }
|
|
|
|
a3ComSysNetworkAnalyzerBridgePortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the port relative to the bridge identified by
|
|
this entry where the analyzer identified by this entry is
|
|
configured."
|
|
::= { a3ComSysNetworkAnalyzerTableEntry 2 }
|
|
|
|
a3ComSysNetworkAnalyzerPhysicalAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (6)) -- 6 octet address in "canonical" order
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The physical address of the bridge port identified by the
|
|
corresponding values of a3ComSysNetworkAnalyzerBridgeIndex and
|
|
a3ComSysNetworkAnayzerBridgePortIndex."
|
|
::= { a3ComSysNetworkAnalyzerTableEntry 3 }
|
|
|
|
a3ComSysNetworkAnalyzerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
valid(1),
|
|
invalid(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the entry. Setting the value of a non-existent
|
|
instance of this object to valid(1) attempts to add the
|
|
corresponding entry to the table. The effect of adding an
|
|
entry to the table is to configure the port for monitoring and
|
|
to disable it for switching. Setting an existing instance of
|
|
this object to invalid(2) attempts to remove the corresponding
|
|
entry from the table. The effect of removing an entry from
|
|
the table is to disable the port for monitoring and to make
|
|
available for switching."
|
|
::= { a3ComSysNetworkAnalyzerTableEntry 4 }
|
|
|
|
-- The Switching Systems MIB network port monitor table.
|
|
|
|
a3ComSysNetworkPortMonitorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysNetworkPortMonitorTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of monitor port entries. A single entry exists in
|
|
this for each bridge port being monitored."
|
|
::= { a3ComSysNetworkMonitor 2 }
|
|
|
|
a3ComSysNetworkPortMonitorTableEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysNetworkPortMonitorTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A port monitor table entry contains information relating a
|
|
bridge port being monitored with the address of the analyzer
|
|
which is being used to monitor the port.
|
|
|
|
The effect of creating an entry for a particular port is to
|
|
enable monitoring of that port by the analyzer specified. To
|
|
create an entry, set the value of the
|
|
a3ComSysNetworkPortMonitorAnalyzerAddress object to the address of
|
|
the network analyzer port. This value should be the same as
|
|
the value of the a3ComSysNetworkAnalyzerPhysicalAddress object for
|
|
the analyzer.
|
|
|
|
The effect of removing an entry for a particular port is to
|
|
disable monitoring of that port. To remove an entry, set the
|
|
value of the corresponding instance of the
|
|
a3ComSysNetworkPortMonitorStatus object to invalid(2)."
|
|
INDEX { a3ComSysNetworkPortMonitorBridgeIndex,
|
|
a3ComSysNetworkPortMonitorBridgePortIndex }
|
|
::= { a3ComSysNetworkPortMonitorTable 1 }
|
|
|
|
A3ComSysNetworkPortMonitorTableEntry ::=
|
|
SEQUENCE {
|
|
a3ComSysNetworkPortMonitorBridgeIndex
|
|
INTEGER,
|
|
a3ComSysNetworkPortMonitorBridgePortIndex
|
|
INTEGER,
|
|
a3ComSysNetworkPortMonitorAnalyzerAddress
|
|
OCTET STRING,
|
|
a3ComSysNetworkPortMonitorStatus
|
|
INTEGER
|
|
}
|
|
|
|
a3ComSysNetworkPortMonitorBridgeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the bridge relative to this agent where the
|
|
monitored port identified by this entry is located."
|
|
::= { a3ComSysNetworkPortMonitorTableEntry 1 }
|
|
|
|
a3ComSysNetworkPortMonitorBridgePortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the port which is being monitored relative to
|
|
the bridge identified by this entry."
|
|
::= { a3ComSysNetworkPortMonitorTableEntry 2 }
|
|
|
|
a3ComSysNetworkPortMonitorAnalyzerAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (6)) -- 6 octet address in "canonical" order
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The physical address of the port where the analyzer,
|
|
which is monitoring the port identified by this entry, is
|
|
located. Setting the value of a non-existent instance of
|
|
this object attempts to add an entry to the table. The effect
|
|
of adding an entry to the table is to enable monitoring of the
|
|
port by the analyzer specified. Setting the value of an
|
|
existing instance of this object will switch the monitored
|
|
port to the new analyzer address."
|
|
::= { a3ComSysNetworkPortMonitorTableEntry 3 }
|
|
|
|
a3ComSysNetworkPortMonitorStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
valid(1),
|
|
invalid(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the entry. Setting an existing instance
|
|
of this object to invalid(2) attempts to remove the
|
|
corresponding entry from the table. The effect of removing
|
|
an entry from the table is to disable monitoring of the
|
|
port."
|
|
::= { a3ComSysNetworkPortMonitorTableEntry 4 }
|
|
|
|
-- The Switching Systems MIB token ring port group. Implementation of
|
|
-- this group is mandatory for agents which manage token ring port
|
|
-- resources.
|
|
|
|
a3ComSysTokenRingPortCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The count of token ring ports managed by this agent."
|
|
::= { a3ComSysTokenRingPort 1 }
|
|
|
|
|
|
-- The Switching Systems MIB token ring port table.
|
|
|
|
a3ComSysTokenRingPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysTokenRingPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of token ring port entries. A single entry exists
|
|
in this list for each token ring port managed by this agent."
|
|
::= { a3ComSysTokenRingPort 2 }
|
|
|
|
a3ComSysTokenRingPortEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysTokenRingPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A token ring port entry contains information about a
|
|
particular token ring port managed by this agent."
|
|
INDEX { a3ComSysTokenRingPortIndex }
|
|
::= { a3ComSysTokenRingPortTable 1 }
|
|
|
|
A3ComSysTokenRingPortEntry ::=
|
|
SEQUENCE {
|
|
a3ComSysTokenRingPortIndex INTEGER,
|
|
a3ComSysTokenRingPortIfIndex INTEGER,
|
|
a3ComSysTokenRingPortLabel DisplayString,
|
|
a3ComSysTokenRingPortInsertStatus INTEGER,
|
|
a3ComSysTokenRingPortType INTEGER,
|
|
a3ComSysTokenRingPortMode INTEGER,
|
|
a3ComSysTokenRingPortSpeed INTEGER,
|
|
a3ComSysTokenRingPortLineErrors Counter,
|
|
a3ComSysTokenRingPortBurstErrors Counter,
|
|
a3ComSysTokenRingPortACErrors Counter,
|
|
a3ComSysTokenRingPortAbortTransErrors Counter,
|
|
a3ComSysTokenRingPortInternalErrors Counter,
|
|
a3ComSysTokenRingPortLostFrameErrors Counter,
|
|
a3ComSysTokenRingPortReceiveCongestionErrors Counter,
|
|
a3ComSysTokenRingPortFrameCopiedErrors Counter,
|
|
a3ComSysTokenRingPortTokenErrors Counter,
|
|
a3ComSysTokenRingPortSoftErrors Counter,
|
|
a3ComSysTokenRingPortHardErrors Counter,
|
|
a3ComSysTokenRingPortTransmitBeacons Counter,
|
|
a3ComSysTokenRingPortLobeWires Counter,
|
|
a3ComSysTokenRingPortRemoves Counter,
|
|
a3ComSysTokenRingPortSingles Counter,
|
|
a3ComSysTokenRingPortFreqErrors Counter,
|
|
a3ComSysTokenRingPortRingStatus INTEGER
|
|
}
|
|
|
|
a3ComSysTokenRingPortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the token ring port identified by this entry,
|
|
relative to this agent."
|
|
::= { a3ComSysTokenRingPortEntry 1 }
|
|
|
|
a3ComSysTokenRingPortIfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the MIB-II ifIndex corresponding to the
|
|
token ring port identified by this entry."
|
|
::= { a3ComSysTokenRingPortEntry 2 }
|
|
|
|
a3ComSysTokenRingPortLabel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ASCII text string describing the token ring port
|
|
identified by this entry."
|
|
::= { a3ComSysTokenRingPortEntry 3 }
|
|
|
|
a3ComSysTokenRingPortInsertStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
inserted(1),
|
|
deinserted(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current value of the link status for the token ring port
|
|
identified by this entry."
|
|
::= { a3ComSysTokenRingPortEntry 4 }
|
|
|
|
a3ComSysTokenRingPortType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
rj45(1),
|
|
other(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specific port type description for the token ring port
|
|
identified by this entry."
|
|
::= { a3ComSysTokenRingPortEntry 5 }
|
|
|
|
a3ComSysTokenRingPortMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
station(1),
|
|
lobe(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current mode of the port. The default mode (station) is
|
|
used to connect a hub to the port. Lobe mode is used to direct
|
|
connect a Token Ring station into the port. This selection
|
|
can only be made on ports 1 and 2 of the module."
|
|
::= { a3ComSysTokenRingPortEntry 6 }
|
|
|
|
a3ComSysTokenRingPortSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fourMegabit(1),
|
|
sixteenMegabit(2),
|
|
sixteenMegabitETR(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current speed of the port. The default speed is
|
|
sixteenMegabit."
|
|
::= { a3ComSysTokenRingPortEntry 7 }
|
|
|
|
a3ComSysTokenRingPortLineErrors OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This counter is incremented when a frame
|
|
or token is copied or repeated by a
|
|
station, the E bit is zero in the frame
|
|
or token and one of the following
|
|
conditions exists: 1) there is a
|
|
non-data bit (J or K bit) between the SD
|
|
and the ED of the frame or token, or
|
|
2) there is an FCS error in the frame."
|
|
::= { a3ComSysTokenRingPortEntry 8 }
|
|
|
|
a3ComSysTokenRingPortBurstErrors OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This counter is incremented when a station
|
|
detects the absence of transitions for five
|
|
half-bit timers (burst-five error)."
|
|
::= { a3ComSysTokenRingPortEntry 9 }
|
|
|
|
a3ComSysTokenRingPortACErrors OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This counter is incremented when a station
|
|
receives an AMP or SMP frame in which A is
|
|
equal to C is equal to 0, and then receives
|
|
another SMP frame with A is equal to C is
|
|
equal to 0 without first receiving an AMP
|
|
frame. It denotes a station that cannot set
|
|
the AC bits properly."
|
|
::= { a3ComSysTokenRingPortEntry 10 }
|
|
|
|
a3ComSysTokenRingPortAbortTransErrors OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This counter is incremented when a station
|
|
transmits an abort delimiter while
|
|
transmitting."
|
|
::= { a3ComSysTokenRingPortEntry 11 }
|
|
|
|
a3ComSysTokenRingPortInternalErrors OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This counter is incremented when a station
|
|
recognizes an internal error."
|
|
::= { a3ComSysTokenRingPortEntry 12 }
|
|
|
|
a3ComSysTokenRingPortLostFrameErrors OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This counter is incremented when a station
|
|
is transmitting and its TRR timer expires.
|
|
This condition denotes a condition where a
|
|
transmitting station in strip mode does not
|
|
receive the trailer of the frame before the
|
|
TRR timer goes off."
|
|
::= { a3ComSysTokenRingPortEntry 13 }
|
|
|
|
a3ComSysTokenRingPortReceiveCongestionErrors OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This counter is incremented when a station
|
|
recognizes a frame addressed to its
|
|
specific address, but has no available
|
|
buffer space indicating that the station
|
|
is congested."
|
|
::= { a3ComSysTokenRingPortEntry 14 }
|
|
|
|
a3ComSysTokenRingPortFrameCopiedErrors OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This counter is incremented when a station
|
|
recognizes a frame addressed to its
|
|
specific address and detects that the FS
|
|
field A bits are set to 1 indicating a
|
|
possible line hit or duplicate address."
|
|
::= { a3ComSysTokenRingPortEntry 15 }
|
|
|
|
a3ComSysTokenRingPortTokenErrors OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This counter is incremented when a station
|
|
acting as the active monitor recognizes an
|
|
error condition that needs a token
|
|
transmitted."
|
|
::= { a3ComSysTokenRingPortEntry 16 }
|
|
|
|
a3ComSysTokenRingPortSoftErrors OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of Soft Errors the interface
|
|
has detected. It directly corresponds to
|
|
the number of Report Error MAC frames
|
|
that this interface has transmitted.
|
|
Soft Errors are those which are
|
|
recoverable by the MAC layer protocols."
|
|
::= { a3ComSysTokenRingPortEntry 17 }
|
|
|
|
a3ComSysTokenRingPortHardErrors OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of times this interface has
|
|
detected an immediately recoverable
|
|
fatal error. It denotes the number of
|
|
times this interface is either
|
|
transmitting or receiving beacon MAC
|
|
frames."
|
|
::= { a3ComSysTokenRingPortEntry 18 }
|
|
|
|
a3ComSysTokenRingPortTransmitBeacons OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of times this interface has
|
|
transmitted a beacon frame."
|
|
::= { a3ComSysTokenRingPortEntry 19 }
|
|
|
|
a3ComSysTokenRingPortLobeWires OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of times the interface has
|
|
detected an open or short circuit in the
|
|
lobe data path. The adapter will be closed
|
|
when this condition occurs."
|
|
::= { a3ComSysTokenRingPortEntry 20 }
|
|
|
|
a3ComSysTokenRingPortRemoves OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of times the interface has
|
|
received a Remove Ring Station MAC frame
|
|
request. When this frame is received
|
|
the interface will enter the close state."
|
|
::= { a3ComSysTokenRingPortEntry 21 }
|
|
|
|
a3ComSysTokenRingPortSingles OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of times the interface has
|
|
sensed that it is the only station on the
|
|
ring. This will happen if the interface
|
|
is the first one up on a ring, or if
|
|
there is a hardware problem."
|
|
::= { a3ComSysTokenRingPortEntry 22 }
|
|
|
|
|
|
a3ComSysTokenRingPortFreqErrors OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The number of times the interface has
|
|
detected that the frequency of the
|
|
incoming signal differs from the expected
|
|
frequency."
|
|
::= { a3ComSysTokenRingPortEntry 23 }
|
|
|
|
a3ComSysTokenRingPortRingStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current interface status which can
|
|
be used to diagnose fluctuating problems
|
|
that can occur on token rings, after a
|
|
station has successfully been added to
|
|
the ring.
|
|
Before an open is completed, this
|
|
object has the value for the 'no status'
|
|
condition. This object is useful for
|
|
debugging problems when the station
|
|
can not even enter the ring.
|
|
The object's value is a sum of
|
|
values, one for each currently applicable
|
|
condition. The following values are
|
|
defined for various conditions:
|
|
0 = No Problems detected
|
|
32 = Ring Recovery
|
|
64 = Single Station
|
|
256 = Remove Received
|
|
512 = reserved
|
|
1024 = Auto-Removal Error
|
|
2048 = Lobe Wire Fault
|
|
4096 = Transmit Beacon
|
|
8192 = Soft Error
|
|
16384 = Hard Error
|
|
32768 = Signal Loss
|
|
131072 = no status, open not completed."
|
|
::= { a3ComSysTokenRingPortEntry 24 }
|
|
|
|
--
|
|
-- a3ComSysFtGroup file transfer mib
|
|
--
|
|
-- The Switching Systems MIB file transfer table.
|
|
--
|
|
|
|
a3ComSysFtTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysFtTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of entries which describe file transfers."
|
|
::= { a3ComSysFtGroup 1 }
|
|
|
|
a3ComSysFtTableEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysFtTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A description of a particular file transfer entry."
|
|
INDEX { a3ComSysFtIndex }
|
|
::= { a3ComSysFtTable 1 }
|
|
|
|
A3ComSysFtTableEntry ::=
|
|
SEQUENCE {
|
|
a3ComSysFtIndex INTEGER,
|
|
a3ComSysFtDirection INTEGER,
|
|
a3ComSysFtLocalStorageType A3ComSysStorageType,
|
|
a3ComSysFtLocalResourceType A3ComSysResourceType,
|
|
a3ComSysFtLocalResourceMask A3ComSysResourceBitMask,
|
|
a3ComSysFtLocalResourceAttribute OBJECT IDENTIFIER,
|
|
a3ComSysFtRemoteAddressType A3ComSysAddressType,
|
|
a3ComSysFtRemoteAddress OCTET STRING,
|
|
a3ComSysFtRemoteFileName DisplayString,
|
|
a3ComSysFtRemoteUserName DisplayString,
|
|
a3ComSysFtRemoteUserPassword OCTET STRING,
|
|
a3ComSysFtForceTransfer INTEGER,
|
|
a3ComSysFtBytesTransferred Counter,
|
|
a3ComSysFtStatus INTEGER,
|
|
a3ComSysFtDetailedStatus OBJECT IDENTIFIER,
|
|
a3ComSysFtDetailedStatusString DisplayString,
|
|
a3ComSysFtOwnerString DisplayString,
|
|
a3ComSysFtRowStatus RowStatus
|
|
}
|
|
|
|
a3ComSysFtIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique index used to identifying this entry."
|
|
::= { a3ComSysFtTableEntry 1 }
|
|
|
|
a3ComSysFtDirection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
localToRemote(1),
|
|
remoteToLocal(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the direction of the file transfer."
|
|
DEFVAL { remoteToLocal }
|
|
::= { a3ComSysFtTableEntry 2 }
|
|
|
|
a3ComSysFtLocalStorageType OBJECT-TYPE
|
|
SYNTAX A3ComSysStorageType
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of storage on the local system to be
|
|
used as the source/destination for the file transfer."
|
|
DEFVAL { 3 } --storageFlashMemory
|
|
::= { a3ComSysFtTableEntry 3 }
|
|
|
|
a3ComSysFtLocalResourceType OBJECT-TYPE
|
|
SYNTAX A3ComSysResourceType
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of resource on the local system to be
|
|
used as the source/destination for the file transfer."
|
|
DEFVAL { 2 } -- resourceSystem
|
|
::= { a3ComSysFtTableEntry 4 }
|
|
|
|
a3ComSysFtLocalResourceMask OBJECT-TYPE
|
|
SYNTAX A3ComSysResourceBitMask
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The indices of the resources on the local system to
|
|
be used as the source/destination for the file transfer.
|
|
The type of resource to which these indices apply is
|
|
specified by the corresponding value of
|
|
a3ComSysFtLocalResourceType. If resourceBridge is used,
|
|
a3ComSysFtLocalResourceMask indicates the bridge slot
|
|
number the filter code will be downloaded.
|
|
For instance, a3ComSysFtLocalResourceMask value of 0x03
|
|
indicates bridge slot number 1 and 2."
|
|
DEFVAL { 128 }
|
|
::= { a3ComSysFtTableEntry 5 }
|
|
|
|
a3ComSysFtLocalResourceAttribute OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An identifier which specifies the particular resource
|
|
attribute on the local system which is the source/destination
|
|
of the file transfer. The resource(s) to which this attribute
|
|
applies is specified by the corresponding values of
|
|
a3ComSysFtLocalResourceType and a3ComSysFtLocalResourceMask."
|
|
DEFVAL { a3ComSysFtSystemOperationalCode }
|
|
::= { a3ComSysFtTableEntry 6 }
|
|
|
|
a3ComSysFtRemoteAddressType OBJECT-TYPE
|
|
SYNTAX A3ComSysAddressType
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of address which is specified by the corresponding
|
|
value of a3ComSysFtRemoteAddress."
|
|
DEFVAL { 2 } --addrIp
|
|
::= { a3ComSysFtTableEntry 7 }
|
|
|
|
a3ComSysFtRemoteAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..32))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The address of the source/destination file on the remote
|
|
system."
|
|
::= { a3ComSysFtTableEntry 8 }
|
|
|
|
a3ComSysFtRemoteFileName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..128))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The full path name of the source/destination file on the
|
|
remote system."
|
|
::= { a3ComSysFtTableEntry 9 }
|
|
|
|
a3ComSysFtRemoteUserName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..128))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user name to be used when requesting the file transfer
|
|
to/from the remote system."
|
|
::= { a3ComSysFtTableEntry 10 }
|
|
|
|
a3ComSysFtRemoteUserPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..128))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The password to be used when requesting the file transfer
|
|
to/from the remote system. When read, this object returns
|
|
a zero length string. Note that, for security reasons,
|
|
some ftp servers may insist on a non-zero length user password."
|
|
::= { a3ComSysFtTableEntry 11 }
|
|
|
|
a3ComSysFtForceTransfer OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
true(1),
|
|
false(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this object to true makes the agent ignore
|
|
non-fatal (i.e. version/id mismatch) errors encountered
|
|
during a file transfer request."
|
|
DEFVAL { false }
|
|
::= { a3ComSysFtTableEntry 12 }
|
|
|
|
a3ComSysFtBytesTransferred OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of bytes successfully transferred."
|
|
::= { a3ComSysFtTableEntry 13 }
|
|
|
|
a3ComSysFtStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusSuccessfulCompletion(1),
|
|
statusInProgress(2),
|
|
statusLocalInvalid(3),
|
|
statusRemoteInvalid(4),
|
|
statusRemoteUnreachable(5),
|
|
statusUserAuthFailed(6),
|
|
statusFileNotFound(7),
|
|
statusFileTooBig(8),
|
|
statusFileIncompatible(9),
|
|
statusError(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the file transfer."
|
|
::= { a3ComSysFtTableEntry 14 }
|
|
|
|
a3ComSysFtDetailedStatus OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Detailed status for the transfer for the particular
|
|
local resource attribute specified by the corresponding
|
|
values of a3ComSysFtLocalStorageType, a3ComSysFtLocalResourceType,
|
|
a3ComSysFtLocalResourceMask, and a3ComSysFtLocalResourceAttribute.
|
|
|
|
Note that this object is only valid in the case where
|
|
a3ComSysFtStatus indicates an error."
|
|
::= { a3ComSysFtTableEntry 15 }
|
|
|
|
a3ComSysFtDetailedStatusString OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Detailed status description for the requested transfer."
|
|
::= { a3ComSysFtTableEntry 16 }
|
|
|
|
a3ComSysFtOwnerString OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..128))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string describing the creator/owner of this entry."
|
|
::= { a3ComSysFtTableEntry 17 }
|
|
|
|
a3ComSysFtRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The row status object controls the creation/deletion of rows
|
|
in this table. Its semantics are the same as those for the
|
|
RowStatus textual convention specified for SNMPv2.
|
|
|
|
Setting this object to createAndGo(4) is not allowed.
|
|
|
|
Setting this object to createAndWait(5) causes an entry
|
|
to be created with a3ComSysFtRowStatus value of notReady(3).
|
|
|
|
Setting this object to active(1) causes the transfer to
|
|
start for the given row. Objects within the row cannot
|
|
be modified once a row has been set to active(1),
|
|
|
|
Setting this object to destroy(6) causes the corresponding
|
|
row to be deleted.
|
|
|
|
Note that a request to set a row to notInService(2) or
|
|
destroy(6) will fail if the current rowStatus value is active(1)
|
|
(i.e. a file transfer is currently in progress). This is
|
|
necessary since aborting a file transfer may leave the
|
|
system in an inconsistent state.
|
|
|
|
Note that, currently, only a single instance of a row
|
|
can be created in this table."
|
|
::= { a3ComSysFtTableEntry 18 }
|
|
|
|
|
|
-- File transfer resource attributes.
|
|
|
|
a3ComSysFtResourceAttributes OBJECT IDENTIFIER ::= { a3ComSysFtGroup 2 }
|
|
|
|
|
|
-- File transfer resource attributes groups.
|
|
|
|
a3ComSysFtSystemAttributes OBJECT IDENTIFIER ::= { a3ComSysFtResourceAttributes 1 }
|
|
|
|
|
|
-- File transfer system resource attributes.
|
|
|
|
a3ComSysFtSystemOperationalCode OBJECT IDENTIFIER ::= { a3ComSysFtSystemAttributes 1 }
|
|
a3ComSysFtSystemConfiguration OBJECT IDENTIFIER ::= { a3ComSysFtSystemAttributes 2 }
|
|
|
|
-- File transfer bridge resource attributes
|
|
|
|
a3ComSysFtSystemBridgeFilterCode OBJECT IDENTIFIER ::= { a3ComSysFtSystemAttributes 3 }
|
|
|
|
-- File transfer detailed resource status.
|
|
|
|
a3ComSysFtDetailedResourceStatus OBJECT IDENTIFIER ::= { a3ComSysFtGroup 3 }
|
|
|
|
|
|
-- File transfer detailed resource status groups.
|
|
|
|
a3ComSysFtSystemDetailedStatus OBJECT IDENTIFIER ::= { a3ComSysFtDetailedResourceStatus 1 }
|
|
|
|
-- File transfer system detailed status.
|
|
|
|
a3ComSysFtSysStatusNotApplicable OBJECT IDENTIFIER ::= { a3ComSysFtSystemDetailedStatus 1 }
|
|
a3ComSysFtSysStatusNoImageLabel OBJECT IDENTIFIER ::= { a3ComSysFtSystemDetailedStatus 2 }
|
|
a3ComSysFtSysStatusConfigIdMismatch OBJECT IDENTIFIER ::= { a3ComSysFtSystemDetailedStatus 3 }
|
|
a3ComSysFtSysStatusChecksumError OBJECT IDENTIFIER ::= { a3ComSysFtSystemDetailedStatus 4 }
|
|
a3ComSysFtSysStatusNvRamError OBJECT IDENTIFIER ::= { a3ComSysFtSystemDetailedStatus 5 }
|
|
a3ComSysFtSysStatusFlashError OBJECT IDENTIFIER ::= { a3ComSysFtSystemDetailedStatus 6 }
|
|
a3ComSysFtSysStatusNoRoom OBJECT IDENTIFIER ::= { a3ComSysFtSystemDetailedStatus 7 }
|
|
|
|
-- File transfer bridge detailed status
|
|
|
|
a3ComSysFtSysBridgeFilterNotApplicable OBJECT IDENTIFIER ::= { a3ComSysFtSystemDetailedStatus 8 }
|
|
a3ComSysFtSysBridgeFilterSyntaxError OBJECT IDENTIFIER ::= { a3ComSysFtSystemDetailedStatus 9 }
|
|
a3ComSysFtSysBridgeFilterdownloadError OBJECT IDENTIFIER ::= { a3ComSysFtSystemDetailedStatus 10 }
|
|
a3ComSysFtSysBridgeFilterNoRoom OBJECT IDENTIFIER ::= { a3ComSysFtSystemDetailedStatus 11 }
|
|
|
|
--
|
|
-- IP Group
|
|
--
|
|
|
|
-- The a3ComSysIpBaseGroup is resreved for future use
|
|
|
|
a3ComSysIpBaseGroup OBJECT IDENTIFIER ::= { a3ComSysIpGroup 1 }
|
|
a3ComSysIpInterfaceGroup OBJECT IDENTIFIER ::= { a3ComSysIpGroup 2 }
|
|
|
|
a3ComSysIpInterfaceCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A count of the total number of IP interfaces configured."
|
|
::= { a3ComSysIpInterfaceGroup 1 }
|
|
|
|
a3ComSysIpInterfaceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysIpInterfaceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of configured IP interfaces."
|
|
::= { a3ComSysIpInterfaceGroup 2 }
|
|
|
|
a3ComSysIpInterfaceEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysIpInterfaceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An individual IP interface."
|
|
INDEX { a3ComSysIpInterfaceIpStackIndex, a3ComSysIpInterfaceAddr, a3ComSysIpInterfaceNetMask }
|
|
::= { a3ComSysIpInterfaceTable 1 }
|
|
|
|
A3ComSysIpInterfaceEntry ::= SEQUENCE {
|
|
a3ComSysIpInterfaceIpStackIndex INTEGER,
|
|
a3ComSysIpInterfaceAddr IpAddress,
|
|
a3ComSysIpInterfaceNetMask IpAddress,
|
|
a3ComSysIpInterfaceIndex INTEGER,
|
|
a3ComSysIpInterfaceBcastAddr INTEGER,
|
|
a3ComSysIpInterfaceCost INTEGER,
|
|
a3ComSysIpInterfaceStatus RowStatus
|
|
}
|
|
|
|
a3ComSysIpInterfaceIpStackIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the IP stack identified by this entry
|
|
relative to this agent."
|
|
::= { a3ComSysIpInterfaceEntry 1 }
|
|
|
|
a3ComSysIpInterfaceAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP address of this entry within the IP stack identified
|
|
within this entry."
|
|
::= { a3ComSysIpInterfaceEntry 2 }
|
|
|
|
a3ComSysIpInterfaceNetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The subnet mask associated with this IP interface. The value of the mask
|
|
is an IP address with all the network bits set to 1 and all the host bits
|
|
set to 0."
|
|
::= { a3ComSysIpInterfaceEntry 3 }
|
|
|
|
a3ComSysIpInterfaceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index value which uniquely identifies the interface
|
|
to which this entry is applicable. lspIPInterfaceIndex maps to
|
|
the same interface as identified by ifIndex in the ifTable. Currently,
|
|
this object can not be modified after creation."
|
|
::= { a3ComSysIpInterfaceEntry 4 }
|
|
|
|
a3ComSysIpInterfaceBcastAddr OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object represents the value of the least significant
|
|
bit of this entry's direct broadcast address. For example,
|
|
a value of one signifies that the host portion of the broadcast
|
|
address is set to all ones."
|
|
DEFVAL { 1 }
|
|
::= { a3ComSysIpInterfaceEntry 5 }
|
|
|
|
a3ComSysIpInterfaceCost OBJECT-TYPE
|
|
SYNTAX INTEGER ( 1..15 )
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The route cost metric used for this entry."
|
|
DEFVAL { 1 }
|
|
::= { a3ComSysIpInterfaceEntry 6 }
|
|
|
|
a3ComSysIpInterfaceStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status column for this IP interface. This object can be set to:
|
|
createAndGo(4)
|
|
destroy(6)
|
|
|
|
The following value may be read:
|
|
active(1)
|
|
|
|
Setting this object to createAndGo(4) causes the agent to
|
|
attempt to create and commit the row based on the contents
|
|
of the object in the row. If all necessary information is
|
|
present in the row and the values are acceptable to the
|
|
agent, the agent will change the status to active(1). If any
|
|
of the necessary objects are not available the agent
|
|
will reject the request.
|
|
|
|
Other objects in this row entry can be individually modified
|
|
while the row status is active(1).
|
|
|
|
Setting this object to destroy(6) will remove this entry."
|
|
::= { a3ComSysIpInterfaceEntry 7 }
|
|
|
|
--
|
|
-- The IPX Group
|
|
--
|
|
|
|
a3ComSysIpxBaseGroup OBJECT IDENTIFIER ::= { a3ComSysIpxGroup 1 }
|
|
a3ComSysIpxInterfaceGroup OBJECT IDENTIFIER ::= { a3ComSysIpxGroup 2 }
|
|
|
|
a3ComSysIpxInterfaceCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A count of the total number of IPX interfaces configured."
|
|
::= { a3ComSysIpxInterfaceGroup 1 }
|
|
|
|
a3ComSysIpxInterfaceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysIpxInterfaceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of configured IPX interfaces."
|
|
::= { a3ComSysIpxInterfaceGroup 2 }
|
|
|
|
a3ComSysIpxInterfaceEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysIpxInterfaceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An individual IPX interface."
|
|
INDEX { a3ComSysIpxInterfaceIpxStackIndex, a3ComSysIpxInterfaceNetNumber }
|
|
::= { a3ComSysIpxInterfaceTable 1 }
|
|
|
|
A3ComSysIpxInterfaceEntry ::= SEQUENCE {
|
|
a3ComSysIpxInterfaceIpxStackIndex INTEGER,
|
|
a3ComSysIpxInterfaceNetNumber IpxNetworkNumber,
|
|
a3ComSysIpxInterfaceIfIndex INTEGER,
|
|
a3ComSysIpxInterfaceCost INTEGER,
|
|
a3ComSysIpxInterfaceFrameType INTEGER,
|
|
a3ComSysIpxInterfaceStatus RowStatus
|
|
}
|
|
|
|
a3ComSysIpxInterfaceIpxStackIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the IPX stack identified by this entry
|
|
relative to this agent."
|
|
::= { a3ComSysIpxInterfaceEntry 1 }
|
|
|
|
a3ComSysIpxInterfaceNetNumber OBJECT-TYPE
|
|
SYNTAX IpxNetworkNumber
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPX Network Number of this entry."
|
|
::= { a3ComSysIpxInterfaceEntry 2 }
|
|
|
|
a3ComSysIpxInterfaceIfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ifIndex of the virtual interface that this IPX interface is
|
|
is configured over. The a3ComSysIpxInterfaceIfIndex identifies a
|
|
virtual interface, for example a VLAN, that this local address
|
|
is associated with for purposes of routing or network management."
|
|
::= { a3ComSysIpxInterfaceEntry 3 }
|
|
|
|
a3ComSysIpxInterfaceCost OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The cost associated with the IPX address of this entry."
|
|
DEFVAL { 1 }
|
|
::= { a3ComSysIpxInterfaceEntry 4 }
|
|
|
|
a3ComSysIpxInterfaceFrameType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
frame-ethernetII(1),
|
|
frame-802-2(2),
|
|
frame-802-3-Raw(3),
|
|
frame-SNAP(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The frame format used for routing frames on this IPX interface. The framing
|
|
formats are for ethernet ports. There are two frame formats for FDDI ports:
|
|
802.2 and FDDI SNAP. The correct FDDI format is automatically chosen if
|
|
this interface is associated with a VLAN interface that contains both ethernet
|
|
and FDDI ports. If the VLAN interface is an FDDI port, than the only
|
|
values that can be written to this object are: frame-802-2(2) and
|
|
frame-SNAP(4). "
|
|
::= { a3ComSysIpxInterfaceEntry 5 }
|
|
|
|
a3ComSysIpxInterfaceStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status column for this IPX interface. This OBJECT can be set to:
|
|
createAndGo(4)
|
|
destroy(6)
|
|
|
|
The following value may be read:
|
|
active(1)
|
|
|
|
Setting this object ot createAndGo(4) causes the agent to
|
|
attempt to create and commit the row based on the contents
|
|
of the object in the row. If all necessary information is
|
|
present in the row and the values are acceptable to the
|
|
agent, the agent will change the status to active(1). If any
|
|
of the necessary objects are not available the agent
|
|
will reject the request.
|
|
|
|
Other objects in this row entry can be individually modified
|
|
while the row status is active(1).
|
|
|
|
Setting this object to destroy(6) will remove this entry."
|
|
::= { a3ComSysIpxInterfaceEntry 6 }
|
|
|
|
--
|
|
-- The Apple Talk Group
|
|
--
|
|
|
|
a3ComSysAppleTalkBaseGroup OBJECT IDENTIFIER ::= { a3ComSysAppleTalkGroup 1 }
|
|
a3ComSysAppleTalkInterfaceGroup OBJECT IDENTIFIER ::= { a3ComSysAppleTalkGroup 2 }
|
|
|
|
-- The AppleTalkInterace Group
|
|
--
|
|
-- Implementation of this group is mandatory for all entities
|
|
-- that implement AppleTalk ports
|
|
|
|
a3ComSysAtInterfaceCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A count of the total number of AppleTalk interfaces configured."
|
|
::= { a3ComSysAppleTalkInterfaceGroup 1 }
|
|
|
|
a3ComSysAtInterfaceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysAtInterfaceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of AppleTalk ports for this entity."
|
|
::= { a3ComSysAppleTalkInterfaceGroup 2 }
|
|
|
|
a3ComSysAtInterfaceEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysAtInterfaceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An individual appletalk interface entry.
|
|
Appletalk entries with row status of active(1)
|
|
cannot be modified but must set to destroy(6)
|
|
and recreated."
|
|
INDEX { a3ComSysAtInterfaceAtStackIndex, a3ComSysAtInterfaceIfIndex }
|
|
::= { a3ComSysAtInterfaceTable 1 }
|
|
|
|
A3ComSysAtInterfaceEntry ::= SEQUENCE {
|
|
a3ComSysAtInterfaceAtStackIndex INTEGER,
|
|
a3ComSysAtInterfaceNetAddress DdpNodeAddress,
|
|
a3ComSysAtInterfaceType INTEGER,
|
|
a3ComSysAtInterfaceNetStart ATNetworkNumber,
|
|
a3ComSysAtInterfaceNetEnd ATNetworkNumber,
|
|
a3ComSysAtInterfaceZoneDefault ATName,
|
|
a3ComSysAtInterfaceZone1 ATName,
|
|
a3ComSysAtInterfaceZone2 ATName,
|
|
a3ComSysAtInterfaceZone3 ATName,
|
|
a3ComSysAtInterfaceZone4 ATName,
|
|
a3ComSysAtInterfaceZone5 ATName,
|
|
a3ComSysAtInterfaceZone6 ATName,
|
|
a3ComSysAtInterfaceZone7 ATName,
|
|
a3ComSysAtInterfaceZone8 ATName,
|
|
a3ComSysAtInterfaceZone9 ATName,
|
|
a3ComSysAtInterfaceZone10 ATName,
|
|
a3ComSysAtInterfaceZone11 ATName,
|
|
a3ComSysAtInterfaceZone12 ATName,
|
|
a3ComSysAtInterfaceZone13 ATName,
|
|
a3ComSysAtInterfaceZone14 ATName,
|
|
a3ComSysAtInterfaceZone15 ATName,
|
|
a3ComSysAtInterfaceIfIndex INTEGER,
|
|
a3ComSysAtInterfaceState INTEGER,
|
|
a3ComSysAtInterfaceStatus RowStatus
|
|
}
|
|
|
|
a3ComSysAtInterfaceAtStackIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the Appletalk stack identified by this entry
|
|
relative to this agent.
|
|
|
|
Setting of this object is required for all interface creations."
|
|
::= { a3ComSysAtInterfaceEntry 1 }
|
|
|
|
a3ComSysAtInterfaceNetAddress OBJECT-TYPE
|
|
SYNTAX DdpNodeAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The AppleTalk network address configured for this
|
|
port."
|
|
::= { a3ComSysAtInterfaceEntry 2 }
|
|
|
|
a3ComSysAtInterfaceType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
seedInterface(1),
|
|
nonseedInterface(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of interface that is configured for this port.
|
|
Setting of this object is required for all interface creations."
|
|
::= { a3ComSysAtInterfaceEntry 3 }
|
|
|
|
a3ComSysAtInterfaceNetStart OBJECT-TYPE
|
|
SYNTAX ATNetworkNumber
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The first AppleTalk network address in the range
|
|
configured for this port. If this port is not a
|
|
native AppleTalk port, this object shall have the
|
|
value of two octets of zero.
|
|
Setting of this object is mandatory only for interfaces
|
|
with a3ComSysAtInterfaceType equal to seedInterface(1)."
|
|
::= { a3ComSysAtInterfaceEntry 4 }
|
|
|
|
a3ComSysAtInterfaceNetEnd OBJECT-TYPE
|
|
SYNTAX ATNetworkNumber
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The last AppleTalk network address in the range
|
|
configured for this port. If the network to which
|
|
this AppleTalk port is connected is a non-extended
|
|
network, or if it is not a native AppleTalk port,
|
|
the value for a3ComSysAtInterfaceNetEnd shall be two octets of
|
|
zero.
|
|
|
|
Setting of this object is mandatory only for
|
|
interfaces with a3ComSysAtInterfaceType equal to seedInterface(1)."
|
|
::= { a3ComSysAtInterfaceEntry 5 }
|
|
|
|
|
|
a3ComSysAtInterfaceZoneDefault OBJECT-TYPE
|
|
SYNTAX ATName
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the default zone for this port. If
|
|
this port only has one zone, that zone is
|
|
represented here.
|
|
|
|
Setting of this object is mandatory for
|
|
interfaces with a3ComSysAtInterfaceType equal to seedInterface(1)."
|
|
::= { a3ComSysAtInterfaceEntry 6 }
|
|
|
|
a3ComSysAtInterfaceZone1 OBJECT-TYPE
|
|
SYNTAX ATName
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Zone name in this entry's zone list.
|
|
|
|
This object may only only be set for interfaces
|
|
with a3ComSysAtInterfaceType equal to seedInterface(1)."
|
|
::= { a3ComSysAtInterfaceEntry 7 }
|
|
|
|
a3ComSysAtInterfaceZone2 OBJECT-TYPE
|
|
SYNTAX ATName
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Zone name in this entry's zone list.
|
|
|
|
This object may only only be set for interfaces
|
|
with a3ComSysAtInterfaceType equal to seedInterface(1)."
|
|
::= { a3ComSysAtInterfaceEntry 8 }
|
|
|
|
a3ComSysAtInterfaceZone3 OBJECT-TYPE
|
|
SYNTAX ATName
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Zone name in this entry's zone list.
|
|
|
|
This object may only only be set for interfaces
|
|
with a3ComSysAtInterfaceType equal to seedInterface(1)."
|
|
::= { a3ComSysAtInterfaceEntry 9 }
|
|
|
|
a3ComSysAtInterfaceZone4 OBJECT-TYPE
|
|
SYNTAX ATName
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Zone name in this entry's zone list.
|
|
|
|
This object may only only be set for interfaces
|
|
with a3ComSysAtInterfaceType equal to seedInterface(1)."
|
|
::= { a3ComSysAtInterfaceEntry 10 }
|
|
|
|
a3ComSysAtInterfaceZone5 OBJECT-TYPE
|
|
SYNTAX ATName
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Zone name in this entry's zone list.
|
|
|
|
This object may only only be set for interfaces
|
|
with a3ComSysAtInterfaceType equal to seedInterface(1)."
|
|
::= { a3ComSysAtInterfaceEntry 11 }
|
|
|
|
a3ComSysAtInterfaceZone6 OBJECT-TYPE
|
|
SYNTAX ATName
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Zone name in this entry's zone list.
|
|
|
|
This object may only only be set for interfaces
|
|
with a3ComSysAtInterfaceType equal to seedInterface(1)."
|
|
::= { a3ComSysAtInterfaceEntry 12 }
|
|
|
|
a3ComSysAtInterfaceZone7 OBJECT-TYPE
|
|
SYNTAX ATName
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Zone name in this entry's zone list.
|
|
|
|
This object may only only be set for interfaces
|
|
with a3ComSysAtInterfaceType equal to seedInterface(1)."
|
|
::= { a3ComSysAtInterfaceEntry 13 }
|
|
|
|
a3ComSysAtInterfaceZone8 OBJECT-TYPE
|
|
SYNTAX ATName
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Zone name in this entry's zone list.
|
|
|
|
This object may only only be set for interfaces
|
|
with a3ComSysAtInterfaceType equal to seedInterface(1)."
|
|
::= { a3ComSysAtInterfaceEntry 14 }
|
|
|
|
a3ComSysAtInterfaceZone9 OBJECT-TYPE
|
|
SYNTAX ATName
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Zone name in this entry's zone list.
|
|
|
|
This object may only only be set for interfaces
|
|
with a3ComSysAtInterfaceType equal to seedInterface(1)."
|
|
::= { a3ComSysAtInterfaceEntry 15 }
|
|
|
|
a3ComSysAtInterfaceZone10 OBJECT-TYPE
|
|
SYNTAX ATName
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Zone name in this entry's zone list.
|
|
|
|
This object may only only be set for interfaces
|
|
with a3ComSysAtInterfaceType equal to seedInterface(1)."
|
|
::= { a3ComSysAtInterfaceEntry 16 }
|
|
|
|
a3ComSysAtInterfaceZone11 OBJECT-TYPE
|
|
SYNTAX ATName
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Zone name in this entry's zone list.
|
|
|
|
This object may only only be set for interfaces
|
|
with a3ComSysAtInterfaceType equal to seedInterface(1)."
|
|
::= { a3ComSysAtInterfaceEntry 17 }
|
|
|
|
a3ComSysAtInterfaceZone12 OBJECT-TYPE
|
|
SYNTAX ATName
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Zone name in this entry's zone list.
|
|
|
|
This object may only only be set for interfaces
|
|
with a3ComSysAtInterfaceType equal to seedInterface(1)."
|
|
::= { a3ComSysAtInterfaceEntry 18 }
|
|
|
|
a3ComSysAtInterfaceZone13 OBJECT-TYPE
|
|
SYNTAX ATName
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Zone name in this entry's zone list.
|
|
|
|
This object may only only be set for interfaces
|
|
with a3ComSysAtInterfaceType equal to seedInterface(1)."
|
|
::= { a3ComSysAtInterfaceEntry 19 }
|
|
|
|
a3ComSysAtInterfaceZone14 OBJECT-TYPE
|
|
SYNTAX ATName
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Zone name in this entry's zone list.
|
|
|
|
This object may only only be set for interfaces
|
|
with a3ComSysAtInterfaceType equal to seedInterface(1)."
|
|
::= { a3ComSysAtInterfaceEntry 20 }
|
|
|
|
a3ComSysAtInterfaceZone15 OBJECT-TYPE
|
|
SYNTAX ATName
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Zone name in this entry's zone list.
|
|
|
|
This object may only only be set for interfaces
|
|
with a3ComSysAtInterfaceType equal to seedInterface(1)."
|
|
::= { a3ComSysAtInterfaceEntry 21 }
|
|
|
|
|
|
a3ComSysAtInterfaceIfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The interface associated with this
|
|
AppleTalk port. The interface identified by a
|
|
particular value of this index is the same interface
|
|
as identified by the same value of ifIndex in the ifTable.
|
|
|
|
Setting of this object is required for all interface creations."
|
|
::= { a3ComSysAtInterfaceEntry 22 }
|
|
|
|
a3ComSysAtInterfaceState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unused(1),
|
|
initialize(2),
|
|
terminate(3),
|
|
failed(4),
|
|
down(5),
|
|
validate(6),
|
|
discover(7),
|
|
waiting(8),
|
|
enabled(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current state of the appletalk interface."
|
|
::= { a3ComSysAtInterfaceEntry 23 }
|
|
|
|
a3ComSysAtInterfaceStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status column for this IP interface. This object can be set to:
|
|
createAndGo(4)
|
|
createAndWait(5)
|
|
destroy(6)
|
|
|
|
The following value may be read:
|
|
active(1)
|
|
notInService(2)
|
|
|
|
Setting this object to createAndGo(4) causes the agent to
|
|
attempt to create and commit the row based on the contents
|
|
of the object in the row. If all necessary information is
|
|
present in the row and the values are acceptable to the
|
|
agent, the agent will change the status to active(1). If any
|
|
of the necessary objects are not available the agent
|
|
will reject the request.
|
|
|
|
Setting this object to createAndWait(5) causes the agent to
|
|
create an entry which has the value notInService(2). Only three
|
|
notInService(2) entries are permitted at any one time.
|
|
Setting a row with status notInService(2) to active(1)
|
|
will cause this entry to change to active(1) if the
|
|
appropriate columns have been set.
|
|
|
|
Setting this object to destroy(6) will remove this entry."
|
|
::= { a3ComSysAtInterfaceEntry 24 }
|
|
|
|
|
|
-- The A3ComSys Module Card group. Implementation of this
|
|
-- group is mandatory for agents which manage system resources for
|
|
-- systems with modular components.
|
|
|
|
a3ComSysModuleCardCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current count of module components present in the
|
|
system."
|
|
::= { a3ComSysModuleCardGroup 1 }
|
|
|
|
|
|
-- The A3ComSys Module Card information table.
|
|
|
|
a3ComSysModuleCardInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysModuleCardInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of module card information entries. A single entry exists in
|
|
this list for each modular component in the system."
|
|
::= { a3ComSysModuleCardGroup 2 }
|
|
|
|
a3ComSysModuleCardInfoEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysModuleCardInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A module card info entry contains information about a
|
|
particular modular component within the system."
|
|
INDEX { a3ComSysModuleCardInfoIndex }
|
|
::= { a3ComSysModuleCardInfoTable 1 }
|
|
|
|
A3ComSysModuleCardInfoEntry ::=
|
|
SEQUENCE {
|
|
a3ComSysModuleCardInfoIndex
|
|
INTEGER,
|
|
a3ComSysModuleCardInfoFamily
|
|
INTEGER,
|
|
a3ComSysModuleCardInfoGenericType
|
|
INTEGER,
|
|
a3ComSysModuleCardInfoSpecificType
|
|
INTEGER,
|
|
a3ComSysModuleCardInfoPartNumber
|
|
DisplayString,
|
|
a3ComSysModuleCardInfoManufacturingDate
|
|
DisplayString,
|
|
a3ComSysModuleCardInfoModuleSerialNumber
|
|
DisplayString,
|
|
a3ComSysModuleCardInfoTLASerialNumber
|
|
DisplayString,
|
|
a3ComSysModuleCardInfo3CNumber
|
|
DisplayString,
|
|
a3ComSysModuleCardInfoICTTestStatus
|
|
INTEGER,
|
|
a3ComSysModuleCardInfoICTTestRevision
|
|
DisplayString,
|
|
a3ComSysModuleCardInfoSystemTestStatus
|
|
INTEGER,
|
|
a3ComSysModuleCardInfoFunctionalTestStatus
|
|
INTEGER,
|
|
a3ComSysModuleCardInfoFunctionalTestRevision
|
|
DisplayString,
|
|
a3ComSysModuleCardInfoBoardRevision
|
|
DisplayString,
|
|
a3ComSysModuleCardInfoRuntimeHours
|
|
INTEGER
|
|
}
|
|
|
|
a3ComSysModuleCardInfoIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the modular component identified by this
|
|
entry."
|
|
::= { a3ComSysModuleCardInfoEntry 1 }
|
|
|
|
a3ComSysModuleCardInfoFamily OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
coreBuilder3500(1),
|
|
superStack7000(2),
|
|
superStack9000(3),
|
|
|
|
coreBuilder9000-RF12R(17),
|
|
coreBuilder9000-RF6MC(18),
|
|
coreBuilder9000-LF20R(19),
|
|
coreBuilder9000-LF10MC(20),
|
|
coreBuilder9000-LF36T(21),
|
|
coreBuilder9000-FG24(22),
|
|
coreBuilder9000-FG9(23),
|
|
coreBuilder9000-LG9MC(24),
|
|
coreBuilder9000-LG9(25)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The family code for this module."
|
|
::= { a3ComSysModuleCardInfoEntry 2 }
|
|
|
|
a3ComSysModuleCardInfoGenericType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
backplaneOrMotherboard(1),
|
|
processorBoard(2),
|
|
enet10MbAnd100MbAdaptor(3),
|
|
enet1GbAdaptor(4),
|
|
fddiAdaptor(5),
|
|
atmAdaptor(6)
|
|
}
|
|
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The generic type code for this module."
|
|
::= { a3ComSysModuleCardInfoEntry 3 }
|
|
|
|
a3ComSysModuleCardInfoSpecificType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
atmSonetOC3Fiber(161),
|
|
atmSonetOC12Fiber(162),
|
|
atmSonetOC3Copper(163),
|
|
atmSonetOC12Copper(164),
|
|
|
|
enet1Gb850nMMultimodeFiber(177),
|
|
enet1Gb1300nMFiber(178),
|
|
enet1GbCoax(179),
|
|
packetSwitchingFabric1000BaseBackplane(180),
|
|
enet1Gb1000BaseTx(181),
|
|
enet1000BaseSxMmfSCandGBIC(183),
|
|
|
|
enet100Mb100BaseTx(225),
|
|
enet10or100BaseTxTelco(226),
|
|
enet100Mb100BaseFx(227),
|
|
enet100Mb100BaseT4(228),
|
|
enet100Mb100BaseTxSTP(229),
|
|
enet100Mb100BaseT2(230),
|
|
|
|
fddiMultimodeSC(241),
|
|
fddiSingleModeSC(242),
|
|
fddiCopperUTP(243),
|
|
fddiCopperSTP(244)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The specific type code for this module."
|
|
::= { a3ComSysModuleCardInfoEntry 4 }
|
|
|
|
a3ComSysModuleCardInfoPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The specific part number for this module."
|
|
::= { a3ComSysModuleCardInfoEntry 5 }
|
|
|
|
a3ComSysModuleCardInfoManufacturingDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date that this module was manufactured in the
|
|
format mm/dd/yyyy."
|
|
::= { a3ComSysModuleCardInfoEntry 6 }
|
|
|
|
a3ComSysModuleCardInfoModuleSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(12))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"3Com serial number."
|
|
::= { a3ComSysModuleCardInfoEntry 7 }
|
|
|
|
a3ComSysModuleCardInfoTLASerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(12))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"TOP level assembly serial number for boards with
|
|
non-removable daughter cards. Null string for
|
|
all other board types."
|
|
::= { a3ComSysModuleCardInfoEntry 8 }
|
|
|
|
a3ComSysModuleCardInfo3CNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(10))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"On a backplane or non-removable module this is the
|
|
3C number of the chassis. On a removable module this
|
|
is the 3C number of the module."
|
|
::= { a3ComSysModuleCardInfoEntry 9 }
|
|
|
|
a3ComSysModuleCardInfoICTTestStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"1 equals test passed, or greater than 1 identifies the
|
|
test number failure (0 or FF indicates field yet not
|
|
written)."
|
|
::= { a3ComSysModuleCardInfoEntry 10 }
|
|
|
|
a3ComSysModuleCardInfoICTTestRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturing ATE test revision number (XX.XX)."
|
|
::= { a3ComSysModuleCardInfoEntry 11 }
|
|
|
|
a3ComSysModuleCardInfoSystemTestStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"1 equals test passed, or greater than 1 identifies the
|
|
test number failure (0 or FF indicates field yet not
|
|
written)."
|
|
::= { a3ComSysModuleCardInfoEntry 12 }
|
|
|
|
a3ComSysModuleCardInfoFunctionalTestStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"1 equals test passed, or greater than 1 identifies the
|
|
test number failure (0 or FF indicates field yet not
|
|
written)."
|
|
::= { a3ComSysModuleCardInfoEntry 13 }
|
|
|
|
a3ComSysModuleCardInfoFunctionalTestRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturing functional test revision number (XX.XX)."
|
|
::= { a3ComSysModuleCardInfoEntry 14 }
|
|
|
|
a3ComSysModuleCardInfoBoardRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Board revision code. "
|
|
::= { a3ComSysModuleCardInfoEntry 15 }
|
|
|
|
a3ComSysModuleCardInfoRuntimeHours OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A total count of the number of hours this module has
|
|
been in operation."
|
|
::= { a3ComSysModuleCardInfoEntry 16 }
|
|
|
|
|
|
|
|
-- The A3ComSys Diagnostics group. Implementation of this
|
|
-- group is mandatory for agents which manage system resources for
|
|
-- systems with modular components.
|
|
|
|
|
|
-- The A3ComSys Diagnostics event information table. Each PI-ROM maintains
|
|
-- its own last diagnostic event information, hence they are tabularized
|
|
-- separately.
|
|
|
|
a3ComSysDiagnosticsInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComSysDiagnosticsInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of module card information entries. A single entry exists in
|
|
this list for each modular component in the system."
|
|
::= { a3ComSysDiagnosticsGroup 1 }
|
|
|
|
a3ComSysDiagnosticsInfoEntry OBJECT-TYPE
|
|
SYNTAX A3ComSysDiagnosticsInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A diagnostics info entry contains information about a particular
|
|
diagnostics event on a modular component within the system."
|
|
INDEX { a3ComSysDiagnosticsInfoIndex }
|
|
::= { a3ComSysDiagnosticsInfoTable 1 }
|
|
|
|
A3ComSysDiagnosticsInfoEntry ::=
|
|
SEQUENCE {
|
|
a3ComSysDiagnosticsInfoIndex
|
|
INTEGER,
|
|
a3ComSysDiagnosticsInfoPOVDiagnosticsRevision
|
|
DisplayString,
|
|
a3ComSysDiagnosticsInfoExtendedDiagnosticsRevision
|
|
DisplayString,
|
|
a3ComSysDiagnosticsInfoDiagnosticFailureCode
|
|
DisplayString,
|
|
a3ComSysDiagnosticsInfoDiagnosticFailureDateTime
|
|
DisplayString,
|
|
a3ComSysDiagnosticsInfoDiagnosticFailureSlotNumber
|
|
INTEGER,
|
|
a3ComSysDiagnosticsInfoDiagnosticFailureCounter
|
|
INTEGER,
|
|
a3ComSysDiagnosticsInfoDiagnosticFieldDOACounter
|
|
INTEGER
|
|
}
|
|
|
|
a3ComSysDiagnosticsInfoIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the diagnostics modular component identified by this
|
|
entry."
|
|
::= { a3ComSysDiagnosticsInfoEntry 1 }
|
|
|
|
a3ComSysDiagnosticsInfoPOVDiagnosticsRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The revision of the POV (power on verification) diagnostics
|
|
software at the most recent failure."
|
|
::= { a3ComSysDiagnosticsInfoEntry 2 }
|
|
|
|
a3ComSysDiagnosticsInfoExtendedDiagnosticsRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The revision of the extended diagnostics software at the
|
|
most recent failure."
|
|
::= { a3ComSysDiagnosticsInfoEntry 3 }
|
|
|
|
a3ComSysDiagnosticsInfoDiagnosticFailureCode OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The code written by the diagnostics at the most recent
|
|
failure. This identifies both the test number and failure
|
|
code in the following format: <testNumber>-<errorCode>.
|
|
If there is no failure then 000-000 is displayed."
|
|
::= { a3ComSysDiagnosticsInfoEntry 4 }
|
|
|
|
a3ComSysDiagnosticsInfoDiagnosticFailureDateTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date and time of the most recent diagnostic failure
|
|
for the module."
|
|
::= { a3ComSysDiagnosticsInfoEntry 5 }
|
|
|
|
a3ComSysDiagnosticsInfoDiagnosticFailureSlotNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The slot number (network adapter cards only) of the most
|
|
recent diagnostic failure for the module."
|
|
::= { a3ComSysDiagnosticsInfoEntry 6 }
|
|
|
|
a3ComSysDiagnosticsInfoDiagnosticFailureCounter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of diagnostic failures logged against this
|
|
module."
|
|
::= { a3ComSysDiagnosticsInfoEntry 7 }
|
|
|
|
a3ComSysDiagnosticsInfoDiagnosticFieldDOACounter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of failures occurring at this module during
|
|
the first 48 hours of operation."
|
|
::= { a3ComSysDiagnosticsInfoEntry 8 }
|
|
|
|
--
|
|
-- The Switching Systems MIB traps.
|
|
--
|
|
|
|
a3ComSysSystemOverTemperatureEvent TRAP-TYPE
|
|
ENTERPRISE switchingSystemsMibGroups
|
|
VARIABLES { a3ComSysSystemOvertemperature }
|
|
DESCRIPTION
|
|
"The trap that is generated when the system temperature
|
|
exceeds a certain threshold."
|
|
::= 1
|
|
|
|
a3ComSysPowerSupplyFailureEvent TRAP-TYPE
|
|
ENTERPRISE switchingSystemsMibGroups
|
|
VARIABLES { a3ComSysPowerSupplyStatusIndex,
|
|
a3ComSysPowerSupplyStatus,
|
|
a3ComSysPowerSupplyStatusSupported }
|
|
DESCRIPTION
|
|
"The trap that is generated when a power supply unit
|
|
fails."
|
|
::= 2
|
|
|
|
a3ComSysChassisSlotOverTemperatureEvent TRAP-TYPE
|
|
ENTERPRISE switchingSystemsMibGroups
|
|
VARIABLES { a3ComSysSlotIndex,
|
|
a3ComSysSlotBoardType,
|
|
a3ComSysSlotBoardRevision,
|
|
a3ComSysSlotBoardStatus,
|
|
a3ComSysSlotOvertemperature,
|
|
a3ComSysSlotConverterBad }
|
|
DESCRIPTION
|
|
"The trap that is generated when the temperature of a
|
|
board in a particular slot exceeds a certain threshold."
|
|
::= 3
|
|
|
|
a3ComSysChassisSlotInsertEvent TRAP-TYPE
|
|
ENTERPRISE switchingSystemsMibGroups
|
|
VARIABLES { a3ComSysSlotIndex,
|
|
a3ComSysSlotBoardType,
|
|
a3ComSysSlotBoardRevision }
|
|
DESCRIPTION
|
|
"The trap that is generated when a board is inserted into a
|
|
particular slot."
|
|
::= 4
|
|
|
|
a3ComSysChassisSlotExtractEvent TRAP-TYPE
|
|
ENTERPRISE switchingSystemsMibGroups
|
|
VARIABLES { a3ComSysSlotIndex }
|
|
DESCRIPTION
|
|
"The trap that is generated when a board is extracted
|
|
from a particular slot."
|
|
::= 5
|
|
|
|
a3ComSysBridgeAddressThresholdEvent TRAP-TYPE
|
|
ENTERPRISE switchingSystemsMibGroups
|
|
VARIABLES { a3ComSysBridgeIndex }
|
|
DESCRIPTION
|
|
"The trap that is generated when the number of addresses
|
|
stored in the bridge reaches a3ComSysBridgeAddressThreshold."
|
|
::= 6
|
|
|
|
a3ComSysSystemFanFailureEvent TRAP-TYPE
|
|
ENTERPRISE switchingSystemsMibGroups
|
|
VARIABLES { a3ComSysSystemFanFailure }
|
|
DESCRIPTION
|
|
"The trap that is generated when one of the system fans
|
|
fails."
|
|
::= 7
|
|
|
|
a3ComSysModuleCardSysOverTemperatureEvent TRAP-TYPE
|
|
ENTERPRISE switchingSystemsMibGroups
|
|
VARIABLES { a3ComSysModuleCardInfoIndex,
|
|
a3ComSysModuleCardInfoFamily,
|
|
a3ComSysModuleCardInfoGenericType }
|
|
DESCRIPTION
|
|
"The trap that is generated when the temperature of
|
|
the system exceeds a certain threshold. This trap is
|
|
generated from agents that support the
|
|
a3ComSysModuleCardInfoTable."
|
|
::= 8
|
|
|
|
a3ComSysModuleCardInsertEvent TRAP-TYPE
|
|
ENTERPRISE switchingSystemsMibGroups
|
|
VARIABLES { a3ComSysModuleCardInfoIndex,
|
|
a3ComSysModuleCardInfoFamily,
|
|
a3ComSysModuleCardInfoGenericType,
|
|
a3ComSysModuleCardInfoSpecificType }
|
|
DESCRIPTION
|
|
"The trap that is generated when a board is inserted into a
|
|
particular modular slot. This trap is generated from agents
|
|
that support the a3ComSysModuleCardInfoTable."
|
|
::= 9
|
|
|
|
a3ComSysModuleCardExtractEvent TRAP-TYPE
|
|
ENTERPRISE switchingSystemsMibGroups
|
|
VARIABLES { a3ComSysModuleCardInfoIndex}
|
|
DESCRIPTION
|
|
"The trap that is generated when a board is extracted
|
|
from a particular modular slot. This trap is generated
|
|
from agents that support the a3ComSysModuleCardInfoTable."
|
|
::= 10
|
|
END
|