Observium_CE/mibs/a3com/A3COM-HUAWEI-USERLOG-MIB

808 lines
28 KiB
Plaintext

-- =================================================================
-- Copyright (C) 2003 by HUAWEI TECHNOLOGIES. All rights reserved
--
-- Description:This mib file is used for management of huawei userlog
-- information.
-- Reference:
-- Version: V1.1
-- History:
-- V1.0
-- 31st Mar 2003
-- tianli, initial version
-- V1.1 2005-07-05
-- Modify value range of hwUserlogNatAclNumber and hwUserlogFlowAclNumber
-- by tanbo02122.
-- Update file format by gaolong.
-- =================================================================
A3COM-HUAWEI-USERLOG-MIB DEFINITIONS ::= BEGIN
IMPORTS
huawei,huaweiMgmt,huaweiDatacomm
FROM A3COM-HUAWEI-OID-MIB
OBJECT-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF
IpAddress, Integer32, Counter32, OBJECT-TYPE,
MODULE-IDENTITY
FROM SNMPv2-SMI;
hwUserLogMIB MODULE-IDENTITY
LAST-UPDATED "200304100000Z" -- April 10, 2003 at 00:00 GMT
ORGANIZATION
"Huawei Technologies co.,Ltd."
CONTACT-INFO
" R&D BeiJing, Huawei Technologies co.,Ltd.
Huawei Bld.,NO.3 Xinxi Rd.,
Shang-Di Information Industry Base,
Hai-Dian District Beijing P.R. China
Zip:100085
Http://www.huawei.com
E-mail:support@huawei.com "
DESCRIPTION
"The A3COM-HUAWEI-USERLOG-MIB contains objects to
Manage configuration and Monitor running state
for userlog feature."
::= { huaweiDatacomm 18 }
hwUserlogObjects OBJECT IDENTIFIER ::= { hwUserLogMIB 1 }
hwUserlogNatObjects OBJECT IDENTIFIER ::= { hwUserlogObjects 1 }
hwUserlogNatVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"NAT LOG version. Currently only version 1 is developed."
::= { hwUserlogNatObjects 1 }
hwUserlogNatSyslog OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
NAT LOG format.
If 1, LOG format is sysLog.
If 0, LOG format is UDP packet.
UDP packet is the default format, and is recommended.
"
::= { hwUserlogNatObjects 2 }
hwUserlogNatSourceIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Source IP address of NAT LOG UDP packet."
::= { hwUserlogNatObjects 3 }
hwUserlogNatFlowBegin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Log the NAT flow when it is created.
If 1, this function is enabled.
If 0, this function is disabled.
This function will be used when real-time monitor required.
"
::= { hwUserlogNatObjects 4 }
hwUserlogNatActiveTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
The active time for long-time existed NAT flow.
Unit: minute. Range: 10 minutes ~ 120 minutes.
When setting it, NAT flow can be logged after an interval of
active time.
This function will be used when real-time monitor required.
The default value 0 means real-time monitor function is disabled.
"
::= { hwUserlogNatObjects 5 }
hwUserlogNatSlotCfgInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwUserlogNatSlotCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of NAT LOG configuration information for the
specified slot."
::= { hwUserlogNatObjects 6 }
hwUserlogNatSlotCfgInfoEntry OBJECT-TYPE
SYNTAX HwUserlogNatSlotCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"NAT LOG Configuration Information Entry for a slot."
INDEX { hwUserlogNatCfgSlotNumber }
::= { hwUserlogNatSlotCfgInfoTable 1 }
HwUserlogNatSlotCfgInfoEntry ::=
SEQUENCE {
hwUserlogNatCfgSlotNumber
Integer32,
hwUserlogNatEnable
Integer32,
hwUserlogNatAclNumber
Integer32,
hwUserlogNatHostAddress
IpAddress,
hwUserlogNatUdpPort
Integer32
}
hwUserlogNatCfgSlotNumber OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number. Specify which slot is configured with NAT LOG. "
::= { hwUserlogNatSlotCfgInfoEntry 1 }
hwUserlogNatEnable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
The NAT LOG feature Enable status.
If 1, NAT LOG is enbled.
If 0, NAT LOG is disabled.
"
::= { hwUserlogNatSlotCfgInfoEntry 2 }
hwUserlogNatAclNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Access-list number.
The value 0 means no ACL is specified.
Only when NAT LOG is enabled, can ACL be configured.
Only NAT flow which match the ACL will be logged.
"
::= { hwUserlogNatSlotCfgInfoEntry 3 }
hwUserlogNatHostAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of NAT LOG server. "
::= { hwUserlogNatSlotCfgInfoEntry 4 }
hwUserlogNatUdpPort OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP Port Number of NAT LOG UDP packet."
::= { hwUserlogNatSlotCfgInfoEntry 5 }
hwUserlogNatSlotRunInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwUserlogNatSlotRunInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of NAT LOG running information for the specified slot."
::= { hwUserlogNatObjects 7 }
hwUserlogNatSlotRunInfoEntry OBJECT-TYPE
SYNTAX HwUserlogNatSlotRunInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"NAT LOG Running Information Entry for a slot."
INDEX { hwUserlogNatRunSlotNumber }
::= { hwUserlogNatSlotRunInfoTable 1 }
HwUserlogNatSlotRunInfoEntry ::=
SEQUENCE {
hwUserlogNatRunSlotNumber
Integer32,
hwUserlogNatTotalEntries
Counter32,
hwUserlogNatTotalPackets
Counter32,
hwUserlogNatFailedEntries
Counter32,
hwUserlogNatFailedPackets
Counter32,
hwUserlogNatClearRunStat
Integer32
}
hwUserlogNatRunSlotNumber OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number. Specify on which slot the NAT LOG statistics
displayed."
::= { hwUserlogNatSlotRunInfoEntry 1 }
hwUserlogNatTotalEntries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of NAT flow entries which are logged."
::= { hwUserlogNatSlotRunInfoEntry 2 }
hwUserlogNatTotalPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of NAT LOG UDP packets generated by the router."
::= { hwUserlogNatSlotRunInfoEntry 3 }
hwUserlogNatFailedEntries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of NAT flow entries failed in outputting."
::= { hwUserlogNatSlotRunInfoEntry 4 }
hwUserlogNatFailedPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of NAT LOG UDP packets failed in outputting."
::= { hwUserlogNatSlotRunInfoEntry 5 }
hwUserlogNatClearRunStat OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Clear the running statistics for NAT LOG. Write-only.
If 1, the running statistics for NAT LOG is resetted.
Other value is invalid.
"
::= { hwUserlogNatSlotRunInfoEntry 6 }
hwUserlogFlowObjects OBJECT IDENTIFIER ::= { hwUserlogObjects 2 }
hwUserlogFlowVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"BAS FLOW LOG version. Currently only version 1 is developed."
::= { hwUserlogFlowObjects 1 }
hwUserlogFlowSyslog OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
BAS FLOW LOG format.
If 1, LOG format is sysLog.
If 0, LOG format is UDP packet.
UDP packet is the default format, and is recommended.
"
::= { hwUserlogFlowObjects 2 }
hwUserlogFlowSourceIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Source IP address of BAS FLOW LOG UDP packet."
::= { hwUserlogFlowObjects 3 }
hwUserlogFlowFlowBegin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Log the BAS flow when it is created.
If 1, this function is enabled.
If 0, this function is disabled.
This function will be used when real-time monitor required.
"
::= { hwUserlogFlowObjects 4 }
hwUserlogFlowActiveTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
The active time for long-time existed BAS flow.
Unit: minute. Range: 10 minutes ~ 120 minutes.
When setting it, BAS flow can be logged after an internal of
active time.
This function will be used when real-time monitor required.
The default value 0 means real-time monitor function is disabled.
"
::= { hwUserlogFlowObjects 5 }
hwUserlogFlowSlotCfgInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwUserlogFlowSlotCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of BAS FLOW LOG configuration information for the
specified slot."
::= { hwUserlogFlowObjects 6 }
hwUserlogFlowSlotCfgInfoEntry OBJECT-TYPE
SYNTAX HwUserlogFlowSlotCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"BAS FLOW LOG Configuration Information Entry for a slot."
INDEX { hwUserlogFlowCfgSlotNumber }
::= { hwUserlogFlowSlotCfgInfoTable 1 }
HwUserlogFlowSlotCfgInfoEntry ::=
SEQUENCE {
hwUserlogFlowCfgSlotNumber
Integer32,
hwUserlogFlowEnable
Integer32,
hwUserlogFlowAclNumber
Integer32,
hwUserlogFlowHostAddress
IpAddress,
hwUserlogFlowUdpPort
Integer32
}
hwUserlogFlowCfgSlotNumber OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number. Specify which slot is configured with BAS FLOW LOG."
::= { hwUserlogFlowSlotCfgInfoEntry 1 }
hwUserlogFlowEnable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
The BAS FLOW LOG feature Enable status.
If 1, BAS FLOW LOG is enbled.
If 0, BAS FLOW LOG is disabled.
"
::= { hwUserlogFlowSlotCfgInfoEntry 2 }
hwUserlogFlowAclNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Access-list number.
The value 0 means no ACL is specified.
Only when BAS FLOW LOG is enabled, can ACL be configured.
Only BAS flow which match the ACL will be logged.
"
::= { hwUserlogFlowSlotCfgInfoEntry 3 }
hwUserlogFlowHostAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of BAS FLOW LOG server. "
::= { hwUserlogFlowSlotCfgInfoEntry 4 }
hwUserlogFlowUdpPort OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP Port Number of BAS FLOW LOG UDP packet."
::= { hwUserlogFlowSlotCfgInfoEntry 5 }
hwUserlogFlowSlotRunInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwUserlogFlowSlotRunInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of BAS FLOW LOG running information for the specified slot."
::= { hwUserlogFlowObjects 7 }
hwUserlogFlowSlotRunInfoEntry OBJECT-TYPE
SYNTAX HwUserlogFlowSlotRunInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Running Information Entry for a slot."
INDEX { hwUserlogFlowRunSlotNumber }
::= { hwUserlogFlowSlotRunInfoTable 1 }
HwUserlogFlowSlotRunInfoEntry ::=
SEQUENCE {
hwUserlogFlowRunSlotNumber
Integer32,
hwUserlogFlowTotalEntries
Counter32,
hwUserlogFlowTotalPackets
Counter32,
hwUserlogFlowFailedEntries
Counter32,
hwUserlogFlowFailedPackets
Counter32,
hwUserlogFlowClearRunStat
Integer32
}
hwUserlogFlowRunSlotNumber OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number. Specify on which slot the BAS FLOW LOG
statistics displayed."
::= { hwUserlogFlowSlotRunInfoEntry 1 }
hwUserlogFlowTotalEntries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of BAS FLOW Entries which are logged."
::= { hwUserlogFlowSlotRunInfoEntry 2 }
hwUserlogFlowTotalPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of FLOW LOG UDP packet generated by the router."
::= { hwUserlogFlowSlotRunInfoEntry 3 }
hwUserlogFlowFailedEntries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of BAS FLOW entries failed in outputting. "
::= { hwUserlogFlowSlotRunInfoEntry 4 }
hwUserlogFlowFailedPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of BAS FLOW LOG UDP packet failed in outputting."
::= { hwUserlogFlowSlotRunInfoEntry 5 }
hwUserlogFlowClearRunStat OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Clear the running statistics for FLOW LOG. Write-only.
If 1, the running statistics for FLOW LOG is resetted.
Other value is invalid.
"
::= { hwUserlogFlowSlotRunInfoEntry 6 }
hwUserlogAccessObjects OBJECT IDENTIFIER ::= { hwUserlogObjects 3 }
hwUserlogAccessVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"BAS ACCESS LOG version. Currently only version 1 is developed."
::= { hwUserlogAccessObjects 1 }
hwUserlogAccessSyslog OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
BAS ACCESS LOG format.
If 1, LOG format is sysLog;
If 0, LOG format is UDP packet.
UDP packet is the default format, and is recommended.
"
::= { hwUserlogAccessObjects 2 }
hwUserlogAccessSourceIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Source IP address of BAS ACCESS LOG UDP packet."
::= { hwUserlogAccessObjects 3 }
hwUserlogAccessSlotCfgInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwUserlogAccessSlotCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of BAS ACCESS LOG configuration information for the specified slot."
::= { hwUserlogAccessObjects 4 }
hwUserlogAccessSlotCfgInfoEntry OBJECT-TYPE
SYNTAX HwUserlogAccessSlotCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"BAS ACCESS LOG Configuration Information Entry for a slot."
INDEX { hwUserlogAccessCfgSlotNumber }
::= { hwUserlogAccessSlotCfgInfoTable 1 }
HwUserlogAccessSlotCfgInfoEntry ::=
SEQUENCE {
hwUserlogAccessCfgSlotNumber
Integer32,
hwUserlogAccessEnable
Integer32,
hwUserlogAccessHostAddress
IpAddress,
hwUserlogAccessUdpPort
Integer32
}
hwUserlogAccessCfgSlotNumber OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number. Specify which slot is configured with BAS ACCESS LOG."
::= { hwUserlogAccessSlotCfgInfoEntry 1 }
hwUserlogAccessEnable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
The BAS ACCESS LOG feature Enable status.
If 1, BAS ACCESS LOG is enbled.
If 0, BAS ACCESS LOG is disabled.
"
::= { hwUserlogAccessSlotCfgInfoEntry 2 }
hwUserlogAccessHostAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of BAS ACCESS LOG server."
::= { hwUserlogAccessSlotCfgInfoEntry 3 }
hwUserlogAccessUdpPort OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP Port Number of BAS ACCESS LOG UDP packet."
::= { hwUserlogAccessSlotCfgInfoEntry 4 }
hwUserlogAccessSlotRunInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwUserlogAccessSlotRunInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of BAS ACCESS LOG running information for the specified slot."
::= { hwUserlogAccessObjects 5 }
hwUserlogAccessSlotRunInfoEntry OBJECT-TYPE
SYNTAX HwUserlogAccessSlotRunInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Running Information Entry for a slot."
INDEX { hwUserlogAccessRunSlotNumber }
::= { hwUserlogAccessSlotRunInfoTable 1 }
HwUserlogAccessSlotRunInfoEntry ::=
SEQUENCE {
hwUserlogAccessRunSlotNumber
Integer32,
hwUserlogAccessTotalEntries
Counter32,
hwUserlogAccessTotalPackets
Counter32,
hwUserlogAccessFailedEntries
Counter32,
hwUserlogAccessFailedPackets
Counter32,
hwUserlogAccessClearRunStat
Integer32
}
hwUserlogAccessRunSlotNumber OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number. Specify on which slot the BAS ACCESS LOG statistics displayed."
::= { hwUserlogAccessSlotRunInfoEntry 1 }
hwUserlogAccessTotalEntries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of BAS ACCESS Records which are logged."
::= { hwUserlogAccessSlotRunInfoEntry 2 }
hwUserlogAccessTotalPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of ACCESS LOG UDP packet generated by the router."
::= { hwUserlogAccessSlotRunInfoEntry 3 }
hwUserlogAccessFailedEntries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of BAS ACCESS entries failed in outputting."
::= { hwUserlogAccessSlotRunInfoEntry 4 }
hwUserlogAccessFailedPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of BAS ACCESS LOG UDP packet failed in outputting."
::= { hwUserlogAccessSlotRunInfoEntry 5 }
hwUserlogAccessClearRunStat OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Clear the running statistics for ACCESS LOG. Write-only.
If 1, the running statistics for ACCESS LOG is resetted.
Other value is invalid.
"
::= { hwUserlogAccessSlotRunInfoEntry 6 }
hwUserlogNotifications OBJECT IDENTIFIER ::= { hwUserLogMIB 2 }
hwUserlogConformance OBJECT IDENTIFIER ::= { hwUserLogMIB 3 }
hwUserlogCompliances OBJECT IDENTIFIER ::= { hwUserlogConformance 1 }
hwUserlogCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities which implement the
Huawei Userlog mib."
MODULE -- this module
MANDATORY-GROUPS { hwUserlogMandatoryGroup }
::= { hwUserlogCompliances 1 }
hwUserlogGroups OBJECT IDENTIFIER ::= { hwUserlogConformance 2 }
hwUserlogMandatoryGroup OBJECT-GROUP
OBJECTS { hwUserlogNatEnable, hwUserlogNatHostAddress, hwUserlogNatUdpPort,
hwUserlogFlowEnable, hwUserlogFlowHostAddress, hwUserlogFlowUdpPort,
hwUserlogAccessEnable, hwUserlogAccessHostAddress, hwUserlogAccessUdpPort
}
STATUS current
DESCRIPTION
"A collection of objects providing mandatory Userlog information."
::= { hwUserlogGroups 1 }
hwUserlogConfigGroup OBJECT-GROUP
OBJECTS { hwUserlogNatVersion, hwUserlogNatSyslog, hwUserlogNatSourceIP,
hwUserlogNatFlowBegin, hwUserlogNatActiveTime, hwUserlogNatCfgSlotNumber,
hwUserlogNatEnable, hwUserlogNatAclNumber, hwUserlogNatHostAddress,
hwUserlogNatUdpPort, hwUserlogFlowVersion, hwUserlogFlowSyslog,
hwUserlogFlowSourceIP, hwUserlogFlowFlowBegin, hwUserlogFlowActiveTime,
hwUserlogFlowCfgSlotNumber, hwUserlogFlowEnable, hwUserlogFlowAclNumber,
hwUserlogFlowHostAddress, hwUserlogFlowUdpPort, hwUserlogAccessVersion,
hwUserlogAccessSyslog, hwUserlogAccessSourceIP, hwUserlogAccessCfgSlotNumber,
hwUserlogAccessEnable, hwUserlogAccessHostAddress, hwUserlogAccessUdpPort
}
STATUS current
DESCRIPTION
"All configurable parameters of Userlog feature."
::= { hwUserlogGroups 2 }
hwUserlogInfoGroup OBJECT-GROUP
OBJECTS { hwUserlogNatTotalEntries, hwUserlogNatTotalPackets,
hwUserlogNatFailedEntries, hwUserlogNatFailedPackets,
hwUserlogFlowTotalEntries, hwUserlogFlowTotalPackets,
hwUserlogFlowFailedEntries, hwUserlogFlowFailedPackets,
hwUserlogAccessTotalEntries, hwUserlogAccessTotalPackets,
hwUserlogAccessFailedEntries, hwUserlogAccessFailedPackets
}
STATUS current
DESCRIPTION
"All running information of Userlog feature."
::= { hwUserlogGroups 3 }
END