Observium_CE/mibs/a3com/A3COM-HUAWEI-ENTITY-EXT-MIB

1534 lines
57 KiB
Plaintext

-- =================================================================
-- Copyright (c) 2004-2012 Hangzhou H3C Tech. Co., Ltd. All rights reserved.
--
-- Description: description of entity extend properties.
-- Reference:
-- History V2.8
-- V1.0 Created by weixinzhe, Thursday, April 22, 2004 at 18:26:02
-- V1.1 modified by yelinhui, add h3cEntityExtMacAddress
-- V1.2 modified by panxidong, add h3cEntityExtErrorStatus
-- V1.3 2004-10-12 updated by gaolong
-- Remove BITS from IMPORTS
-- V1.4 2005-02-25 modified by longyin
-- Add error status stackPortBlocked(22) and stackPortFailed(23)
-- for h3cEntityExtErrorStatus
-- V1.5 2006-05-16 modified by wangsihai
-- Add error status sensorError(81) in h3cEntityExtErrorStatus
-- V1.6 2006-07-03 modified by lifengguang
-- Add h3cEntityExtManuTable
-- V1.7 2007-09-21 modified by lifengguang
-- Add notification object h3cEntityExtSFPAlarmOn and h3cEntityExtSFPAlarmOff
-- Add h3cEntityExtPowerTable
-- V1.8 2007-11-19 modified by jinyi
-- Add h3cEntityExtCpuMaxUsage
-- V1.9 2008-02-27 modified by lifengguang
-- Add Trap nodes: h3cEntityExtSFPPhony
-- V2.0 2008-07-11 modified by lisong
-- Add h3cProcessTable
-- Add notification object h3cEntityInsert and h3cEntityRemove
-- V2.1 2008-07-14 modified by lifengguang
-- Add error status hardwareFaulty(91) in h3cEntityExtErrorStatus
-- Add Trap nodes: h3cEntityExtForcedPowerOff and h3cEntityExtForcedPowerOn
-- Add Trap nodes: h3cEntityExtFaultAlarmOn and h3cEntityExtFaultAlarmOff
-- V2.2 2008-10-24 modified by lifengguang
-- Add nodes h3cEntityExtLowerTemperatureThreshold and
-- h3cEntityExtShutdownTemperatureThreshold in h3cEntityExtStateTable
-- Add trap nodes h3cEntityExtResourceLack and h3cEntityExtResourceEnough
-- in h3cEntityExtTrapsPrefix
-- Add trap nodes h3cEntityExtTemperatureLower, h3cEntityExtTemperatureTooUp
-- and h3cEntityExtTemperatureNormal in h3cEntityExtTrapsPrefix
-- V2.3 2009-04-07 Added trap nodes h3cEntityExternalAlarmOccur and
-- h3cEntityExternalAlarmRecover
-- v2.4 2009-05-05 Added h3cEntityExtCpuAvgUsage, h3cEntityExtMemAvgUsage,
-- h3cEntityExtPhyMemSize, h3cEntityExtMemType, h3cEntityExtPhyCpuFrequency,
-- h3cEntityExtFirstUsedDate,
-- h3cEntityExtCpuUsageThresholdRecover, h3cEntityExtMemUsageThresholdRecover
-- V2.5 2010-08-09
-- Added h3cEntityExtShutdownLowerTemperatureThreshold,
-- h3cEntityExtCriticalLowerTemperatureThreshold,
-- h3cEntityExtCritLowerTempThresholdNotification and
-- h3cEntityExtTemperatureTooLow by zhanglei 06807.
-- Added h3cEntityExtMemAllocatedFailed, h3cEntityExtECCParityAlarm,
-- h3cEntityExtTrapDescription, h3cEntityExtECCParityAlarmStatus
-- by zhangqingjun 02357.
-- Modified description of h3cEntityExtPhyMemSize by haoyan 06611.
-- V2.6 2010-12-06
-- Added h3cEntityExtFanDirectionNotPreferred, h3cEntityExtFanDirectionNotAccord
-- by lifengguang 03035.
-- V2.7 2011-04-06
-- Added h3cEntityExtSFPInvalid, h3cEntityExtSFPInvalidNow and
-- h3cEntityExtSFPInvalidInDays by songhao 02718.
-- Changed SYNTAX of h3cEntityExtMemSize and h3cEntityExtPhyMemSize
-- from Integer32 to Unsigned32 by songhao 02718.
-- V2.8 2011-08-30
-- Added h3cEntityExtCpuUsageRecoverThreshold;
-- Added h3cEntityExtCpuUsageRecoverThreshold to h3cEntityExtCpuUsageThresholdNotfication and
-- h3cEntityExtCpuUsageThresholdRecover by shuaixiaojuan 04117.
-- Added h3cEntityExtFirstTrapTime by duyanbing 04404.
-- =================================================================
A3COM-HUAWEI-ENTITY-EXT-MIB DEFINITIONS ::= BEGIN
IMPORTS
h3cCommon
FROM A3COM-HUAWEI-OID-MIB
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
FROM SNMPv2-CONF
OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, Integer32,
Unsigned32, Gauge32, TimeTicks
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, MacAddress, DateAndTime, DisplayString
FROM SNMPv2-TC
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
entPhysicalIndex, entPhysicalName, entPhysicalDescr
FROM ENTITY-MIB;
h3cEntityExtend MODULE-IDENTITY
LAST-UPDATED "201111260000Z"
ORGANIZATION
"Hangzhou H3C Technologies Co., Ltd."
CONTACT-INFO
"Platform Team H3C Technologies Co., Ltd.
Hai-Dian District Beijing P.R. China
http://www.h3c.com
Zip: 100085"
DESCRIPTION
"The private MIB file includes the general extent
information of the device."
::= { h3cCommon 6 }
H3cAdminState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The administrative state for this object, and it is possible to
set the state when needed.
A value of locked means the resource is administratively prohibited
from use. A value of shuttingDown means that usage is
administratively limited to current instances of use.
A value of unlocked means the resource is not administratively
prohibited from use."
REFERENCE
"ITU Recommendation X.731, 'Information Technology - Open
Systems Interconnection - System Management: State
Management Function', 1992"
SYNTAX INTEGER
{
notSupported(1),
locked(2),
shuttingDown(3),
unlocked(4)
}
H3cOperState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
" Represents the possible values of operational states.
A value of disabled means the resource is totally
inoperable. A value of enabled means the resource
is partially or fully operable."
REFERENCE
"ITU Recommendation X.731, 'Information Technology - Open
Systems Interconnection - System Management: State
Management Function', 1992"
SYNTAX INTEGER
{
notSupported (1),
disabled(2),
enabled(3),
dangerous(4)
}
H3cAlarmStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Represents the possible values of alarm status.
When no bits of this attribute are set, then none of the
status conditions described below are present. When the
value of under repair is set, the resource is currently
being repaired.
When the value of critical is set, one or more critical
alarms are active against the resource. When the value of
major is set, one or more major alarms are active against
the resource. When the value of minor is set, one or more
minor alarms are active against the resource. When the
value of warning is set, one or more warning alarms are
active against the resource. When the value of
indeterminate is set, one or more alarms of indeterminate
severity are active against the resource.
When the value of alarm outstanding is set, one or more
alarms is active against the resource. The fault may or may
not be disabling."
REFERENCE
"ITU Recommendation X.731, 'Information Technology - Open
Systems Interconnection - System Management: State
Management Function', 1992"
SYNTAX BITS
{
notSupported (0),
underRepair(1),
critical(2),
major(3),
minor(4),
alarmOutstanding(5),
warning (6), -- Not defined in X.731
indeterminate (7) -- Not defined in X.731
}
H3cStandbyStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
" Represents the possible values of standby status.
A value of hotStandby means the resource is not providing
service, but is will be immediately able to take over the
role of the resource to be backed-up, without the need for
initialization activity, and will contain the same
information as the resource to be backed up. A value of
coldStandy means that the resource is to back-up another
resource, but will not be immediately able to take over
the role of a resource to be backed up, and will require
some initialization activity. A value of providingService
means the resource is providing service."
REFERENCE
"ITU Recommendation X.731, 'Information Technology - Open
Systems Interconnection - System Management: State
Management Function', 1992"
SYNTAX INTEGER
{
notSupported (1),
hotStandby(2),
coldStandby(3),
providingService(4)
}
h3cEntityExtObjects OBJECT IDENTIFIER ::= { h3cEntityExtend 1 }
-- MIB contains four groups
h3cEntityExtState OBJECT IDENTIFIER ::= { h3cEntityExtObjects 1 }
h3cEntityExtStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cEntityExtStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per physical entity, There is
always at least one row for an 'overall' physical entity.
The information in each row may be not include all the object
in this table, because of the entity need not some of the
information here."
::= { h3cEntityExtState 1 }
h3cEntityExtStateEntry OBJECT-TYPE
SYNTAX H3cEntityExtStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The information about a particular physical entity."
INDEX { h3cEntityExtPhysicalIndex }
::= { h3cEntityExtStateTable 1 }
H3cEntityExtStateEntry ::= SEQUENCE {
h3cEntityExtPhysicalIndex
Integer32,
h3cEntityExtAdminStatus
H3cAdminState,
h3cEntityExtOperStatus
H3cOperState,
h3cEntityExtStandbyStatus
H3cStandbyStatus,
h3cEntityExtAlarmLight
H3cAlarmStatus,
h3cEntityExtCpuUsage
Integer32,
h3cEntityExtCpuUsageThreshold
Integer32,
h3cEntityExtMemUsage
Integer32,
h3cEntityExtMemUsageThreshold
Integer32,
h3cEntityExtMemSize
Unsigned32,
h3cEntityExtUpTime
Integer32,
h3cEntityExtTemperature
Integer32,
h3cEntityExtTemperatureThreshold
Integer32,
h3cEntityExtVoltage
Integer32,
h3cEntityExtVoltageLowThreshold
Integer32,
h3cEntityExtVoltageHighThreshold
Integer32,
h3cEntityExtCriticalTemperatureThreshold
Integer32,
h3cEntityExtMacAddress
MacAddress,
h3cEntityExtErrorStatus
INTEGER,
h3cEntityExtCpuMaxUsage
Integer32,
h3cEntityExtLowerTemperatureThreshold
Integer32,
h3cEntityExtShutdownTemperatureThreshold
Integer32,
h3cEntityExtPhyMemSize
Unsigned32,
h3cEntityExtPhyCpuFrequency
Integer32,
h3cEntityExtFirstUsedDate
DateAndTime,
h3cEntityExtCpuAvgUsage
Integer32,
h3cEntityExtMemAvgUsage
Integer32,
h3cEntityExtMemType
OCTET STRING,
h3cEntityExtCriticalLowerTemperatureThreshold
Integer32,
h3cEntityExtShutdownLowerTemperatureThreshold
Integer32,
h3cEntityExtCpuUsageRecoverThreshold
Integer32
}
h3cEntityExtPhysicalIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The index of h3cEntityExtStateTable.
This index is identical to entPhysicalIndex in ENTITY-MIB"
::= { h3cEntityExtStateEntry 1 }
h3cEntityExtAdminStatus OBJECT-TYPE
SYNTAX H3cAdminState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The administrative state for this object."
::= { h3cEntityExtStateEntry 2 }
h3cEntityExtOperStatus OBJECT-TYPE
SYNTAX H3cOperState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operate state for this object."
::= { h3cEntityExtStateEntry 3 }
h3cEntityExtStandbyStatus OBJECT-TYPE
SYNTAX H3cStandbyStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used for monitoring standby status.
Not all entities support this object."
::= { h3cEntityExtStateEntry 4 }
h3cEntityExtAlarmLight OBJECT-TYPE
SYNTAX H3cAlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm status for this entity. It does not include
the severity of alarms raised on child components. In
this condition, there will be a alarm light on the entity,
the object should have the same status with it."
::= { h3cEntityExtStateEntry 5 }
h3cEntityExtCpuUsage OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The CPU usage for this entity. Generally, the CPU usage
will calculate the overall CPU usage on the entity, and it
is not sensible with the number of CPU on the entity."
::= { h3cEntityExtStateEntry 6 }
h3cEntityExtCpuUsageThreshold OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold for the CPU usage. When the CPU usage exceeds
the threshold, a notification will be sent."
::= { h3cEntityExtStateEntry 7 }
h3cEntityExtMemUsage OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The memory usage for the entity. This object indicates what
percent of memory are used."
::= { h3cEntityExtStateEntry 8 }
h3cEntityExtMemUsageThreshold OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold for the Memory usage, When the memory usage
exceeds the threshold, a notification will be sent."
::= { h3cEntityExtStateEntry 9 }
h3cEntityExtMemSize OBJECT-TYPE
SYNTAX Unsigned32
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The size of memory for the entity."
::= { h3cEntityExtStateEntry 10 }
h3cEntityExtUpTime OBJECT-TYPE
SYNTAX Integer32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The uptime for the entity. The meaning of uptime is
when the entity is up, and the value of the object
will add 1 seconds while the entity is running."
::= { h3cEntityExtStateEntry 11 }
h3cEntityExtTemperature OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The temperature for the entity."
::= { h3cEntityExtStateEntry 12 }
h3cEntityExtTemperatureThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold for the temperature. When the temperature
exceeds the threshold, a notification will be sent."
::= { h3cEntityExtStateEntry 13 }
h3cEntityExtVoltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The voltage for the entity."
::= { h3cEntityExtStateEntry 14 }
h3cEntityExtVoltageLowThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The low-threshold for the voltage.
When voltage is lower than low-threshold, a notification will be
sent."
::= { h3cEntityExtStateEntry 15 }
h3cEntityExtVoltageHighThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The high-threshold for the voltage.
When voltage greater than high-threshold, a notification will be
sent."
::= { h3cEntityExtStateEntry 16 }
h3cEntityExtCriticalTemperatureThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The threshold for the critical Temperature. When temperature
exceeds the critical temperature, a notification will be sent."
::= { h3cEntityExtStateEntry 17 }
h3cEntityExtMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC Address of the entity."
::= { h3cEntityExtStateEntry 18 }
h3cEntityExtErrorStatus OBJECT-TYPE
SYNTAX INTEGER
{
notSupported(1),
normal(2),
postFailure(3),
entityAbsent(4),
poeError(11),
stackError(21),
stackPortBlocked(22),
stackPortFailed(23),
sfpRecvError(31),
sfpSendError(32),
sfpBothError(33),
fanError (41),
psuError(51),
rpsError(61),
moduleFaulty(71),
sensorError(81),
hardwareFaulty(91)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate the error state of this entity object. Now it only
supports Port, general power supply, RPS power supply and
board/Subcard. It may have one of these values.
The following four values can be used for all kinds of entities.
notSupported(1) means this entity can not support this function.
normal(2) means the statement of this entity is normal. for ports,
it doesn't differentiate 10M/s, 100M/s, 1000M/s, duplex and
half-duplex. For fan, power supply and board-Subcard, it means
their states are normal.
postFailure(3) means the entity fails to POST.
entityAbsent(4) means the entity is absent now.
The following values is depended on the entity .
For Port entities, it may have the following values. If its POST
is failure,
then the value of the instance will be postFailure(3), otherwise
the value will be normal(2).
If enable power supply over Ethernet on this port is failure,
the value of this instance will be poeError(11), otherwise it will
be normal(2).
For stack port, if it connects to another stack port normally, and
these two units merge into one stack, then the value of this
instance will be normal(2).
If something wrong occurs and the unit can not merge into stack,
the value of this instance will be stackPortFailed(23). If the
stack port forms resilient daisy chain with another stack port
on the other unit, the value of this instance will be
stackPortBlocked(22).
For SFP ports, if it fail to receive, the value of this instance
will be sfpRecvError(31), if it fail to send, the value is
sfpSendError(32), if it fail to send and receive, the value is
sfpBothError(33), otherwise it will be normal(2).
fanError(41) means that the fan stops working.
psuError(51) means that the Power Supply Unit is in the state of
fault.
rpsError(61) means the RPS is in the state of fault.
moduleFaulty(71) means the Module is in the state of fault.
sensorError(81) means the sensor is in the state of fault.
hardwareFaulty(91) means the hardware of specified entity is in the state of fault.
NMS must be compatible with the states which may be added
in the future."
::= { h3cEntityExtStateEntry 19 }
h3cEntityExtCpuMaxUsage OBJECT-TYPE
SYNTAX Integer32(0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximal CPU usage for the entity in the period of time."
::= { h3cEntityExtStateEntry 20 }
h3cEntityExtLowerTemperatureThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold for the lower Temperature. When temperature runs
under the threshold, a notification will be sent."
::= { h3cEntityExtStateEntry 21 }
h3cEntityExtShutdownTemperatureThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold for the shutdown Temperature. When temperature
exceeds the threshold, a notification will be sent and the entity
will be shutdown."
::= { h3cEntityExtStateEntry 22 }
h3cEntityExtPhyMemSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The memory size of entity. This is the physical attribute of entity."
::= { h3cEntityExtStateEntry 23 }
h3cEntityExtPhyCpuFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The CPU frequency of entity. Unit of measure is MHZ."
::= { h3cEntityExtStateEntry 24 }
h3cEntityExtFirstUsedDate OBJECT-TYPE
SYNTAX DateAndTime (SIZE(8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The first used date of the entity."
::= { h3cEntityExtStateEntry 25 }
h3cEntityExtCpuAvgUsage OBJECT-TYPE
SYNTAX Integer32(0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average CPU usage for the entity in a period of time."
::= { h3cEntityExtStateEntry 26 }
h3cEntityExtMemAvgUsage OBJECT-TYPE
SYNTAX Integer32(0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average memory usage for the entity in a period of time."
::= { h3cEntityExtStateEntry 27 }
h3cEntityExtMemType OBJECT-TYPE
SYNTAX OCTET STRING(SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The memory type of entity."
::= { h3cEntityExtStateEntry 28 }
h3cEntityExtCriticalLowerTemperatureThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold for the critical Temperature. When temperature
exceeds the critical lower temperature, a notification will be sent."
::= { h3cEntityExtStateEntry 29 }
h3cEntityExtShutdownLowerTemperatureThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold for the shutdown Temperature. When temperature
exceeds the lower threshold, a notification will be sent and the entity
will be shutdown."
::= { h3cEntityExtStateEntry 30 }
h3cEntityExtCpuUsageRecoverThreshold OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The recover threshold for the CPU usage. When the CPU usage falls down to
the threshold, a notification is sent. The h3cEntityExtCpuUsageRecoverThreshold
must be less than or equal to the h3cEntityExtCpuUsageThreshold."
DEFVAL { 100 }
::= { h3cEntityExtStateEntry 31 }
h3cEntityExtManu OBJECT IDENTIFIER ::= { h3cEntityExtObjects 2 }
h3cEntityExtManuTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cEntityExtManuEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table about device manufacture information."
::= { h3cEntityExtManu 1 }
h3cEntityExtManuEntry OBJECT-TYPE
SYNTAX H3cEntityExtManuEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The device manufacture information about a particular physical
entity."
INDEX { h3cEntityExtManuPhysicalIndex }
::= { h3cEntityExtManuTable 1 }
H3cEntityExtManuEntry ::= SEQUENCE {
h3cEntityExtManuPhysicalIndex
Integer32,
h3cEntityExtManuSerialNum
SnmpAdminString,
h3cEntityExtManuBuildInfo
SnmpAdminString,
h3cEntityExtManuBOM
SnmpAdminString,
h3cEntityExtMacAddressCount
Unsigned32
}
h3cEntityExtManuPhysicalIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The index of h3cEntityExtManuTable.
This index is identical to entPhysicalIndex in ENTITY-MIB."
::= { h3cEntityExtManuEntry 1 }
h3cEntityExtManuSerialNum OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Manufacture serial number.
The manufacture serial number of the entity such as chassis,
module, and so on. It is got from the device when manufacturing.
For low level box-device, the manufacture serial number is the
device-number of System Control Board(SCB for short), it is written
into the SCB directly; for middle level or high level frame-device,
the manufacture serial number is the device-numbers of SCB and
Service Board, because the SCB, Service Board and chassis are
separate to sale and the device-number of chassis can not be
written into board."
::= { h3cEntityExtManuEntry 2 }
h3cEntityExtManuBuildInfo OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Device version information.
The device version information of the entity such as chassis,
module, and so on. It consists of software version information
and hardware version information."
::= { h3cEntityExtManuEntry 3 }
h3cEntityExtManuBOM OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Device BOM code.
The device BOM code of the entity such as chassis, module, and so
on. It is the component code of ERP system, which can be
disassembled from device-number."
::= { h3cEntityExtManuEntry 4 }
h3cEntityExtMacAddressCount OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address count.
The count of MAC addresses of the entity, such as chassis, module,
or port, and so on."
::= { h3cEntityExtManuEntry 5 }
h3cEntityExtPower OBJECT IDENTIFIER ::= { h3cEntityExtObjects 3 }
h3cEntityExtPowerTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cEntityExtPowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes the power information of all the physical
entity on the device, such as the fans, the subcards, the boards,
etc."
::= { h3cEntityExtPower 1 }
h3cEntityExtPowerEntry OBJECT-TYPE
SYNTAX H3cEntityExtPowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entity power information about a particular physical entity."
INDEX { h3cEntityExtPowerPhysicalIndex }
::= { h3cEntityExtPowerTable 1 }
H3cEntityExtPowerEntry ::= SEQUENCE {
h3cEntityExtPowerPhysicalIndex
Integer32,
h3cEntityExtNominalPower
Gauge32,
h3cEntityExtCurrentPower
Gauge32,
h3cEntityExtAveragePower
Integer32,
h3cEntityExtPeakPower
Integer32
}
h3cEntityExtPowerPhysicalIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The index of h3cEntityExtPowerTable.
This index is identical to entPhysicalIndex in ENTITY-MIB."
::= { h3cEntityExtPowerEntry 1 }
h3cEntityExtNominalPower OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nominal power of the entity expressed in milliWatts."
::= { h3cEntityExtPowerEntry 2 }
h3cEntityExtCurrentPower OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured usage power of the entity expressed in milliWatts."
::= { h3cEntityExtPowerEntry 3 }
h3cEntityExtAveragePower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The average power consumed by the entity expressed in milliWatts.
Writing a value of zero to this object resets its value to zero.
Writing any other value to this object has no effect on its value
and an error is returned."
::= { h3cEntityExtPowerEntry 4 }
h3cEntityExtPeakPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The peak power consumed by the entity expressed in milliWatts.
Writing a value of zero to this object resets its value to zero.
Writing any other value to this object has no effect on its value
and an error is returned."
::= { h3cEntityExtPowerEntry 5 }
-- Process Table
h3cProcessObjects OBJECT IDENTIFIER ::= { h3cEntityExtObjects 4 }
h3cProcessTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cProcessEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Table describes the information about a particular process,
namely a task."
::= { h3cProcessObjects 1 }
h3cProcessEntry OBJECT-TYPE
SYNTAX H3cProcessEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The information about a particular process, namely a task."
INDEX { h3cProcessID }
::= { h3cProcessTable 1 }
H3cProcessEntry ::= SEQUENCE {
h3cProcessID Unsigned32,
h3cProcessName DisplayString,
h3cProcessUtil5Min Unsigned32
}
h3cProcessID OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the identifier of process, namely task ID
in system."
::= { h3cProcessEntry 1 }
h3cProcessName OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the process name."
::= { h3cProcessEntry 2 }
h3cProcessUtil5Min OBJECT-TYPE
SYNTAX Unsigned32(0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides a general idea of how busy a process caused
the processor to be over a 5 minute period. The ratio is calculated
by the overall CPU usage caused by the process."
::= { h3cProcessEntry 3 }
-- End
h3cEntityExtTraps OBJECT IDENTIFIER ::= { h3cEntityExtend 2 }
h3cEntityExtTrapsPrefix OBJECT IDENTIFIER ::= { h3cEntityExtTraps 0 }
h3cEntityExtTrapsInfor OBJECT IDENTIFIER ::= { h3cEntityExtTraps 1 }
h3cEntityExtTemperatureThresholdNotification NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
h3cEntityExtTemperature,
h3cEntityExtTemperatureThreshold,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight
}
STATUS current
DESCRIPTION
"The h3cEntityExtTemperatureThresholdNotification
indicates the temperature exceeded the threshold.
In this condition, user should check the status and the
environment of the entity, sometimes it happens because
of the failure of air-condition."
::= { h3cEntityExtTrapsPrefix 1 }
h3cEntityExtVoltageLowThresholdNotification NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
h3cEntityExtVoltage,
h3cEntityExtVoltageLowThreshold,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight
}
STATUS current
DESCRIPTION
"The h3cEntityExtVoltageLowThresholdNotification indicates
the voltage is lower than the threshold.
If the voltage is lower too much than the entity needs,
the entity will halt."
::= { h3cEntityExtTrapsPrefix 2 }
h3cEntityExtVoltageHighThresholdNotification NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
h3cEntityExtVoltage,
h3cEntityExtVoltageHighThreshold,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight
}
STATUS current
DESCRIPTION
"The h3cEntityExtVoltageHighThresholdNotification indicates
the voltage is higher than the threshold.
If the voltage is higher too much than the entity needs,
The entity may be damaged by the high voltage."
::= { h3cEntityExtTrapsPrefix 3 }
h3cEntityExtCpuUsageThresholdNotfication NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
h3cEntityExtCpuUsage,
h3cEntityExtCpuUsageThreshold,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight,
h3cEntityExtCpuUsageRecoverThreshold,
h3cEntityExtFirstTrapTime
}
STATUS current
DESCRIPTION
"The h3cEntityExtCpuUsageThresholdNotfication indicates
the entity is overloaded."
::= { h3cEntityExtTrapsPrefix 4 }
h3cEntityExtMemUsageThresholdNotification NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
h3cEntityExtMemUsage,
h3cEntityExtMemUsageThreshold,
h3cEntityExtMemSize,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight,
h3cEntityExtFirstTrapTime
}
STATUS current
DESCRIPTION
"The h3cEntityExtMemUsageThresholdNotification indicates
the entity is overloaded."
::= { h3cEntityExtTrapsPrefix 5 }
h3cEntityExtOperEnabled NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight
}
STATUS current
DESCRIPTION
"The trap indicates the entity is operable at present."
::= { h3cEntityExtTrapsPrefix 6 }
h3cEntityExtOperDisabled NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight
}
STATUS current
DESCRIPTION
"The trap indicates the entity is not operable at present."
::= { h3cEntityExtTrapsPrefix 7 }
h3cEntityExtCriticalTemperatureThresholdNotification NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
h3cEntityExtTemperature,
h3cEntityExtCriticalTemperatureThreshold,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight
}
STATUS current
DESCRIPTION
"The h3cEntityExtCriticalTemperatureThresholdNotification
indicates the temperature exceeds the critical temperature.
In this condition, user should check the status and the
environment of the entity, sometimes it happens because
of the failure of air-condition."
::= { h3cEntityExtTrapsPrefix 8 }
h3cEntityExtSFPAlarmOn NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
h3cEntityExtErrorStatus,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight
}
STATUS current
DESCRIPTION
"The trap is generated when the SFP module fails
or runs abnormally for some particular reason."
::= { h3cEntityExtTrapsPrefix 9 }
h3cEntityExtSFPAlarmOff NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
h3cEntityExtErrorStatus,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight
}
STATUS current
DESCRIPTION
"The trap is generated when the SFP module restores to
normal status."
::= { h3cEntityExtTrapsPrefix 10 }
h3cEntityExtSFPPhony NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
entPhysicalName,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight
}
STATUS current
DESCRIPTION
"This module is NOT sold by authorized manufacturer.
The normal function of the device or assume the maintenance
responsibility thereof will NOT be guaranteed.
The trap is generated periodically after a phony module has been
found."
::= { h3cEntityExtTrapsPrefix 11 }
h3cEntityInsert NOTIFICATION-TYPE
OBJECTS { entPhysicalDescr, h3cEntityExtAdminStatus, h3cEntityExtOperStatus }
STATUS current
DESCRIPTION
"The trap is generated when a removeable entity inserting to
device."
::= { h3cEntityExtTrapsPrefix 12 }
h3cEntityRemove NOTIFICATION-TYPE
OBJECTS { entPhysicalDescr, h3cEntityExtAdminStatus, h3cEntityExtOperStatus }
STATUS current
DESCRIPTION
"The trap is generated when a removeable entity removing from
device."
::= { h3cEntityExtTrapsPrefix 13 }
h3cEntityExtForcedPowerOff NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
entPhysicalName,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight
}
STATUS current
DESCRIPTION
"The trap indicates the entity is forced to power off."
::= { h3cEntityExtTrapsPrefix 14 }
h3cEntityExtForcedPowerOn NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
entPhysicalName,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight
}
STATUS current
DESCRIPTION
"The trap indicates the entity is forced to power on."
::= { h3cEntityExtTrapsPrefix 15 }
h3cEntityExtFaultAlarmOn NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
entPhysicalName,
h3cEntityExtErrorStatus,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight
}
STATUS current
DESCRIPTION
"The trap indicates a fault occures on the specified entity."
::= { h3cEntityExtTrapsPrefix 16 }
h3cEntityExtFaultAlarmOff NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
entPhysicalName,
h3cEntityExtErrorStatus,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight
}
STATUS current
DESCRIPTION
"The trap indicates a fault disappears on the specified entity."
::= { h3cEntityExtTrapsPrefix 17 }
h3cEntityExtResourceLack NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
entPhysicalName
}
STATUS current
DESCRIPTION
"The trap indicates that a kind of resource is not enough on the
specified entity."
::= { h3cEntityExtTrapsPrefix 18 }
h3cEntityExtResourceEnough NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
entPhysicalName
}
STATUS current
DESCRIPTION
"The trap indicates that the entity recovers from the status of no
enough resource."
::= { h3cEntityExtTrapsPrefix 19 }
h3cEntityExtTemperatureLower NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
entPhysicalName,
h3cEntityExtTemperature,
h3cEntityExtLowerTemperatureThreshold,
h3cEntityExtAdminStatus
}
STATUS current
DESCRIPTION
"The trap indicates the temperature of a specified entity is under
the lower threshold. In this condition, user should check the
status and the environment of the entity, sometimes it goes wrong
for some reason."
::= { h3cEntityExtTrapsPrefix 20 }
h3cEntityExtTemperatureTooUp NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
entPhysicalName,
h3cEntityExtTemperature,
h3cEntityExtShutdownTemperatureThreshold,
h3cEntityExtAdminStatus
}
STATUS current
DESCRIPTION
"The trap indicates the temperature of a specified entity exceeded
the shutdown threshold. In this condition, user should check the
status and the environment of the entity, sometimes it goes wrong
for some reason."
::= { h3cEntityExtTrapsPrefix 21 }
h3cEntityExtTemperatureNormal NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
entPhysicalName,
h3cEntityExtTemperature,
h3cEntityExtLowerTemperatureThreshold,
h3cEntityExtTemperatureThreshold,
h3cEntityExtAdminStatus
}
STATUS current
DESCRIPTION
"The trap indicates the temperature of a specified entity recover
from abnormal status."
::= { h3cEntityExtTrapsPrefix 22 }
h3cEntityExternalAlarmOccur NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
entPhysicalName
}
STATUS current
DESCRIPTION
"The trap is generated when the monitored device connected to the
specified entity fails."
::= { h3cEntityExtTrapsPrefix 23 }
h3cEntityExternalAlarmRecover NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
entPhysicalName
}
STATUS current
DESCRIPTION
"The trap is generated when the failed device connected to the
specified entity returns to normal."
::= { h3cEntityExtTrapsPrefix 24 }
h3cEntityExtCpuUsageThresholdRecover NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
h3cEntityExtCpuUsage,
h3cEntityExtCpuUsageThreshold,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight,
h3cEntityExtCpuUsageRecoverThreshold,
h3cEntityExtFirstTrapTime
}
STATUS current
DESCRIPTION
"The trap indicates the CPU usage descends the threshold."
::= { h3cEntityExtTrapsPrefix 25 }
h3cEntityExtMemUsageThresholdRecover NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
h3cEntityExtMemUsage,
h3cEntityExtMemUsageThreshold,
h3cEntityExtMemSize,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight,
h3cEntityExtFirstTrapTime
}
STATUS current
DESCRIPTION
"The trap indicates the memory usage descends the threshold."
::= { h3cEntityExtTrapsPrefix 26 }
h3cEntityExtMemAllocatedFailed NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
h3cEntityExtTrapDescription
}
STATUS current
DESCRIPTION
"The trap indicates the memory allocated failed."
::= { h3cEntityExtTrapsPrefix 27 }
h3cEntityExtECCParityAlarm NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
h3cEntityExtECCParityAlarmStatus,
h3cEntityExtTrapDescription
}
STATUS current
DESCRIPTION
"The trap indicates the ECC(Error Correction Code) parity error alarm."
::= { h3cEntityExtTrapsPrefix 28 }
h3cEntityExtCritLowerTempThresholdNotification NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
entPhysicalName,
h3cEntityExtTemperature,
h3cEntityExtCriticalLowerTemperatureThreshold
}
STATUS current
DESCRIPTION
"The h3cEntityExtCritLowerTempThresholdNotification
indicates the temperature is lower than the threshold.
If the temperature is lower too much than the entity needs,
the entity will halt."
::= { h3cEntityExtTrapsPrefix 29 }
h3cEntityExtTemperatureTooLow NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
entPhysicalName,
h3cEntityExtTemperature,
h3cEntityExtShutdownLowerTemperatureThreshold
}
STATUS current
DESCRIPTION
"The h3cEntityExtTemperatureTooLow indicates the temperature
is lower than the threshold.
If the temperature is lower too much than the entity needs,
the entity halts now."
::= { h3cEntityExtTrapsPrefix 30 }
h3cEntityExtFanDirectionNotPreferred NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
entPhysicalName
}
STATUS current
DESCRIPTION
"This trap indicates the specified fan's direction does not
accord with preferred. The two parameters indicate the entity
index and physical name of fan."
::= { h3cEntityExtTrapsPrefix 31 }
h3cEntityExtFanDirectionNotAccord NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
entPhysicalName
}
STATUS current
DESCRIPTION
"This trap indicates the direction of fans does not accord
with each other. The two parameters indicate the parent
entity of the fans."
::= { h3cEntityExtTrapsPrefix 32 }
h3cEntityExtSFPInvalid NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
entPhysicalName,
h3cEntityExtSFPInvalidInDays
}
STATUS current
DESCRIPTION
"The transceiver module is not compatible with the interface card.
The authorized manufacturer therefore shall NOT guarantee
the normal function of the transceiver.
The transceiver module will be invalidated in days.
Please replace it with a compatible one as soon as possible.
The trap is generated periodically after a phony transceiver module
has been found."
::= { h3cEntityExtTrapsPrefix 33 }
h3cEntityExtSFPInvalidNow NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
entPhysicalName
}
STATUS current
DESCRIPTION
"This transceiver module is not compatible with the interface card.
The authorized manufacturer therefore shall NOT guarantee
the normal function of the transceiver.
The trap is generated after a phony transceiver module
has been found."
::= { h3cEntityExtTrapsPrefix 34 }
h3cEntityExtTrapDescription OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..255))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The information of trap."
::= { h3cEntityExtTrapsInfor 1 }
h3cEntityExtECCParityAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
l1cache(2), -- cpu l1 data cache err
l2cache(3), -- cpu l2 data cache err
sdram(4), -- sdram err for cpu
mac(5), -- mac err
tcam(6), -- tcam err
ingressbuffer(7), -- IB err
egressbuffer(8), -- EB err
lpm(9), -- lpm err
controlmemory(10) -- controlmemory err
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"ECC parity error."
::= { h3cEntityExtTrapsInfor 2 }
h3cEntityExtSFPInvalidInDays OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The days when the transceiver module is still valid,
but after those days, it will be invaldated."
::= { h3cEntityExtTrapsInfor 3 }
h3cEntityExtFirstTrapTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Represents the first trap time."
::= { h3cEntityExtTrapsInfor 4 }
-- Conformance and Compliance
h3cEntityExtConformance OBJECT IDENTIFIER ::= { h3cEntityExtend 3 }
h3cEntityExtCompliances OBJECT IDENTIFIER ::= { h3cEntityExtConformance 1 }
-- this module
h3cEntityExtCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for systems supporting this MIB."
MODULE -- this module
MANDATORY-GROUPS { h3cEntityExtGroup, h3cEntityExtNotificationGroup,
h3cEntityExtManuGroup, h3cEntityExtPowerGroup }
OBJECT h3cEntityExtAdminStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT h3cEntityExtCpuUsageThreshold
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT h3cEntityExtMemUsageThreshold
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT h3cEntityExtTemperatureThreshold
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT h3cEntityExtVoltageLowThreshold
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT h3cEntityExtVoltageHighThreshold
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { h3cEntityExtCompliances 1 }
h3cEntityExtGroups OBJECT IDENTIFIER ::= { h3cEntityExtConformance 2 }
h3cEntityExtGroup OBJECT-GROUP
OBJECTS {
h3cEntityExtPhysicalIndex,
h3cEntityExtAdminStatus,
h3cEntityExtOperStatus,
h3cEntityExtStandbyStatus,
h3cEntityExtAlarmLight,
h3cEntityExtCpuUsage,
h3cEntityExtCpuUsageThreshold,
h3cEntityExtMemUsage,
h3cEntityExtMemUsageThreshold,
h3cEntityExtMemSize,
h3cEntityExtUpTime,
h3cEntityExtTemperature,
h3cEntityExtTemperatureThreshold,
h3cEntityExtVoltage,
h3cEntityExtVoltageLowThreshold,
h3cEntityExtVoltageHighThreshold,
h3cEntityExtCriticalTemperatureThreshold,
h3cEntityExtMacAddress,
h3cEntityExtErrorStatus,
h3cEntityExtCpuMaxUsage,
h3cEntityExtLowerTemperatureThreshold,
h3cEntityExtShutdownTemperatureThreshold,
h3cEntityExtPhyMemSize,
h3cEntityExtPhyCpuFrequency,
h3cEntityExtFirstUsedDate,
h3cEntityExtCpuAvgUsage,
h3cEntityExtMemAvgUsage,
h3cEntityExtMemType,
h3cEntityExtCriticalLowerTemperatureThreshold,
h3cEntityExtShutdownLowerTemperatureThreshold,
h3cEntityExtCpuUsageRecoverThreshold
}
STATUS current
DESCRIPTION
"Entity Extend group."
::= { h3cEntityExtGroups 1 }
h3cEntityExtNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { h3cEntityExtTemperatureThresholdNotification,
h3cEntityExtVoltageLowThresholdNotification,
h3cEntityExtVoltageHighThresholdNotification,
h3cEntityExtCpuUsageThresholdNotfication,
h3cEntityExtMemUsageThresholdNotification,
h3cEntityExtOperEnabled,
h3cEntityExtOperDisabled,
h3cEntityExtCriticalTemperatureThresholdNotification,
h3cEntityExtSFPAlarmOn,
h3cEntityExtSFPAlarmOff,
h3cEntityExtSFPPhony,
h3cEntityInsert,
h3cEntityRemove,
h3cEntityExtForcedPowerOff,
h3cEntityExtForcedPowerOn,
h3cEntityExtFaultAlarmOn,
h3cEntityExtFaultAlarmOff,
h3cEntityExtResourceLack,
h3cEntityExtResourceEnough,
h3cEntityExtTemperatureLower,
h3cEntityExtTemperatureTooUp,
h3cEntityExtTemperatureNormal,
h3cEntityExternalAlarmOccur,
h3cEntityExternalAlarmRecover,
h3cEntityExtCpuUsageThresholdRecover,
h3cEntityExtMemUsageThresholdRecover,
h3cEntityExtMemAllocatedFailed,
h3cEntityExtECCParityAlarm,
h3cEntityExtCritLowerTempThresholdNotification,
h3cEntityExtTemperatureTooLow,
h3cEntityExtFanDirectionNotPreferred,
h3cEntityExtFanDirectionNotAccord,
h3cEntityExtSFPInvalid,
h3cEntityExtSFPInvalidNow
}
STATUS current
DESCRIPTION
"Entity Extend Notification group."
::= { h3cEntityExtGroups 2 }
h3cEntityExtManuGroup OBJECT-GROUP
OBJECTS {
h3cEntityExtManuPhysicalIndex,
h3cEntityExtManuSerialNum,
h3cEntityExtManuBuildInfo,
h3cEntityExtManuBOM,
h3cEntityExtMacAddressCount
}
STATUS current
DESCRIPTION
"Standard Device Manufacture Information group."
::= { h3cEntityExtGroups 3 }
h3cEntityExtPowerGroup OBJECT-GROUP
OBJECTS {
h3cEntityExtPowerPhysicalIndex,
h3cEntityExtNominalPower,
h3cEntityExtCurrentPower,
h3cEntityExtAveragePower,
h3cEntityExtPeakPower
}
STATUS current
DESCRIPTION
"Standard Entity Power Information group."
::= { h3cEntityExtGroups 4 }
END