Observium_CE/includes/discovery/sensors/fortinet-fortigate-mib.inc.php

96 lines
3.4 KiB
PHP

<?php
/**
* Observium
*
* This file is part of Observium.
*
* @package observium
* @subpackage discovery
* @copyright (C) Adam Armstrong
*
*/
// Currently not possible convert to definitions because type detection is hard, based on descriptions
// SAME code in ATEN-IPMI-MIB
$oids = snmpwalk_multipart_oid($device, "fgHwSensorTable", [], "FORTINET-FORTIGATE-MIB");
print_debug_vars($oids);
foreach ($oids as $index => $entry) {
$descr = $entry['fgHwSensorEntName'];
$oid_name = 'fgHwSensorEntValue';
$oid_num = '.1.3.6.1.4.1.12356.101.4.3.2.1.3.' . $index;
$scale = 1;
$value = $entry[$oid_name];
if (empty($descr) && $value == 0) {
continue;
}
// Detect class based on descr anv value (this is derp, table not have other data for detect class
if (str_iends($descr, [' Temp', ' Temperature'])) {
if ($value == 0) {
continue;
}
$descr = str_replace([' Temperature', ' Temp' ], '', $descr);
$class = 'temperature';
} elseif (str_icontains_array($descr, 'Fan')) {
if ($value == 0) {
continue;
}
if ($value > 100) {
$class = 'fanspeed';
} elseif ($value > 0) {
$class = 'load';
}
} elseif (str_iends($descr, [' Curr', ' Current', ' IIN' ])) {
if ($value == 0) {
continue;
}
$descr = str_replace([' Curr', ' Current' ], '', $descr);
$class = 'current';
} elseif (str_iends($descr, [' Pwr', ' Power', ' POUT' ])) {
if ($value == 0) {
continue;
}
$descr = str_replace([' Pwr', ' Power' ], '', $descr);
$class = 'power';
} elseif (preg_match('/\d+V(SB|DD)?\d*$/', $descr) || preg_match('/P\d+V\d+/', $descr) ||
str_icontains_array($descr, [ 'VCC', 'VPP', 'VTT', 'VDD', 'VDQ', 'VBAT', 'VSA', 'Vcore', 'VIN', 'VOUT',
'Vbus', 'Vsht', 'VDimm', 'Vcpu', 'PVNN', 'SOC', 'VMEM' ])) {
if ($value == 0) {
continue;
}
$class = 'voltage';
} elseif (str_icontains_array($descr, 'Status')) {
// FORTINET-FORTIGATE-MIB::fgHwSensorEntName.45 = STRING: PS1 Status
// FORTINET-FORTIGATE-MIB::fgHwSensorEntName.50 = STRING: PS2 Status
// FORTINET-FORTIGATE-MIB::fgHwSensorEntValue.45 = STRING: 0
// FORTINET-FORTIGATE-MIB::fgHwSensorEntValue.50 = STRING: 9
// FORTINET-FORTIGATE-MIB::fgHwSensorEntAlarmStatus.45 = INTEGER: false(0)
// FORTINET-FORTIGATE-MIB::fgHwSensorEntAlarmStatus.50 = INTEGER: true(1)
$descr = str_ireplace('Status', 'Alarm Status', $descr);
$oid_name = 'fgHwSensorEntAlarmStatus';
$oid_num = '.1.3.6.1.4.1.12356.101.4.3.2.1.4.' . $index;
$type = 'fgHwSensorEntAlarmStatus';
$value = $entry[$oid_name];
discover_status_ng($device, $mib, $oid_name, $oid_num, $index, $type, $descr, $value, ['entPhysicalClass' => 'powersupply']);
continue;
} else {
if ($value == 0) {
continue;
}
// FIXME, not always?
$class = 'temperature';
}
discover_status_ng($device, $mib, 'fgHwSensorEntAlarmStatus', '.1.3.6.1.4.1.12356.101.4.3.2.1.4.' . $index, $index,
'fgHwSensorEntAlarmStatus', $descr, $entry['fgHwSensorEntAlarmStatus']);
discover_sensor_ng($device, $class, $mib, $oid_name, $oid_num, $index, $descr, $scale, $value);
}
// EOF