34 lines
6.1 KiB
SQL

CREATE TABLE IF NOT EXISTS `cmpMemPool` ( `cmp_id` int(11) NOT NULL auto_increment, `Index` varchar(8) NOT NULL, `cmpName` varchar(32) NOT NULL, `cmpValid` varchar(8) NOT NULL, `device_id` int(11) NOT NULL, `cmpUsed` int(11) NOT NULL, `cmpFree` int(11) NOT NULL, `cmpLargestFree` int(11) NOT NULL, `cmpAlternate` tinyint(4) default NULL, PRIMARY KEY (`cmp_id`), KEY `device_id` (`device_id`)) ENGINE=MyISAM DEFAULT CHARSET=latin1;
CREATE TABLE IF NOT EXISTS `hrDevice` ( `hrDevice_id` int(11) NOT NULL auto_increment, `device_id` int(11) NOT NULL, `hrDeviceIndex` int(11) NOT NULL, `hrDeviceDescr` text NOT NULL, `hrDeviceType` text NOT NULL, `hrDeviceErrors` int(11) NOT NULL, `hrDeviceStatus` text NOT NULL, `hrProcessorLoad` tinyint(4) default NULL, PRIMARY KEY (`hrDevice_id`), KEY `device_id` (`device_id`)) ENGINE=MyISAM DEFAULT CHARSET=latin1;
ALTER TABLE `entPhysical` MODIFY COLUMN `entPhysicalHardwareRev` VARCHAR( 16 ) NULL AFTER `entPhysicalName` ,MODIFY COLUMN `entPhysicalFirmwareRev` VARCHAR( 16 ) NULL AFTER `entPhysicalHardwareRev` ,MODIFY COLUMN `entPhysicalSoftwareRev` VARCHAR( 16 ) NULL AFTER `entPhysicalFirmwareRev` ,MODIFY COLUMN `entPhysicalAlias` VARCHAR( 32 ) NULL AFTER `entPhysicalSoftwareRev` ,MODIFY COLUMN `entPhysicalAssetID` VARCHAR( 32 ) NULL AFTER `entPhysicalAlias` ,MODIFY COLUMN `entPhysicalIsFRU` VARCHAR( 8 ) NULL AFTER `entPhysicalAssetID`;
ALTER TABLE `devices` MODIFY COLUMN `last_discovered` timestamp NULL DEFAULT NULL AFTER `last_polled`;
ALTER TABLE `storage` MODIFY COLUMN `storage_type` VARCHAR( 32 ) NULL DEFAULT NULL AFTER `storage_index`;
ALTER TABLE `devices` MODIFY `type` varchar(8) DEFAULT 'unknown';
ALTER TABLE `devices` CHANGE `os` `os` VARCHAR( 32 ) NULL DEFAULT NULL;
CREATE TABLE IF NOT EXISTS `dbSchema` ( `revision` int(11) NOT NULL default '0', PRIMARY KEY (`revision`)) ENGINE=MyISAM DEFAULT CHARSET=latin1;
CREATE TABLE IF NOT EXISTS `voltage` ( `volt_id` int(11) NOT NULL auto_increment, `volt_host` int(11) NOT NULL default '0', `volt_oid` varchar(64) NOT NULL, `volt_descr` varchar(32) NOT NULL default '', `volt_precision` int(11) NOT NULL default '1', `volt_current` int(11) NOT NULL default '0', `volt_limit` int(11) NOT NULL default '60', PRIMARY KEY (`volt_id`), KEY `volt_host` (`volt_host`)) ENGINE=InnoDB DEFAULT CHARSET=latin1;
CREATE TABLE IF NOT EXISTS `fanspeed` ( `fan_id` int(11) NOT NULL auto_increment, `fan_host` int(11) NOT NULL default '0', `fan_oid` varchar(64) NOT NULL, `fan_descr` varchar(32) NOT NULL default '', `fan_precision` int(11) NOT NULL default '1', `fan_current` int(11) NOT NULL default '0', `fan_limit` int(11) NOT NULL default '60', PRIMARY KEY (`fan_id`), KEY `fan_host` (`fan_host`)) ENGINE=InnoDB DEFAULT CHARSET=latin1;
ALTER TABLE `voltage` ADD `volt_limit_low` int(11) NULL DEFAULT NULL AFTER `volt_limit`;
ALTER TABLE `voltage` CHANGE `volt_current` `volt_current` FLOAT(3) NULL DEFAULT NULL;
ALTER TABLE `voltage` CHANGE `volt_limit` `volt_limit` FLOAT(3) NULL DEFAULT NULL;
ALTER TABLE `voltage` CHANGE `volt_limit_low` `volt_limit_low` FLOAT(3) NULL DEFAULT NULL;
ALTER TABLE `fanspeed` ADD `fan_index` INT NOT NULL AFTER `fan_host` , ADD `fan_mibtype` VARCHAR( 32 ) NOT NULL AFTER `fan_index`;
ALTER TABLE `fanspeed` CHANGE `fan_host` `device_id` INT( 11 ) NOT NULL DEFAULT '0';
ALTER TABLE `voltage` CHANGE `volt_host` `device_id` INT( 11 ) NOT NULL DEFAULT '0';
CREATE TABLE IF NOT EXISTS `processors` ( `processor_id` int(11) NOT NULL AUTO_INCREMENT, `entPhysicalIndex` int(11) NOT NULL, `device_id` int(11) NOT NULL, `processor_oid` int(11) NOT NULL, `processor_type` int(11) NOT NULL, `processor_usage` int(11) NOT NULL, `processor_description` varchar(64) NOT NULL, PRIMARY KEY (`processor_id`), KEY `cpuCPU_id` (`processor_id`,`device_id`) ) ENGINE=MyISAM DEFAULT CHARSET=latin1 AUTO_INCREMENT=1 ;
ALTER TABLE `processors` MODIFY COLUMN `hrDeviceIndex` int(11) NULL AFTER `entPhysicalIndex`;
ALTER TABLE `processors` MODIFY COLUMN `processor_index` varchar(32) NOT NULL AFTER `processor_oid`;
ALTER TABLE `processors` CHANGE `processor_descr` `processor_descr` varchar(64) NOT NULL;
ALTER TABLE `fanspeed` CHANGE `fan_mibtype` `fan_type` varchar(64) NOT NULL ;
ALTER TABLE `voltage` ADD `volt_index` VARCHAR( 8 ) NOT NULL AFTER `volt_oid`,ADD `volt_type` VARCHAR( 32 ) NOT NULL AFTER `volt_index` ;
ALTER TABLE `processors` CHANGE `processor_type` `processor_type` varchar(16) NOT NULL;
ALTER TABLE `bgpPeers_cbgp` CHANGE `afi` `afi` VARCHAR( 16 ) NOT NULL , CHANGE `safi` `safi` VARCHAR( 16 ) NOT NULL;
ALTER TABLE `eventlog` MODIFY COLUMN `reference` VARCHAR( 64 ) NOT NULL AFTER `type`;
ALTER TABLE `processors` CHANGE `processor_oid` `processor_oid` VARCHAR( 128 ) NOT NULL;
ALTER TABLE eventlog CHANGE `type` `type` VARCHAR( 64 ) NOT NULL;
CREATE TABLE IF NOT EXISTS `mempools` ( `mempool_id` int(11) NOT NULL AUTO_INCREMENT, `mempool_index` varchar(8) CHARACTER SET latin1 NOT NULL, `entPhysicalIndex` int(11) DEFAULT NULL, `hrDeviceIndex` int(11) DEFAULT NULL, `mempool_type` varchar(32) CHARACTER SET latin1 NOT NULL, `mempool_precision` int(11) NOT NULL DEFAULT '1', `mempool_descr` varchar(32) CHARACTER SET latin1 NOT NULL, `device_id` int(11) NOT NULL, `mempool_used` int(11) NOT NULL, `mempool_free` int(11) NOT NULL, `mempool_total` int(11) NOT NULL, `mempool_largestfree` int(11) DEFAULT NULL, `mempool_lowestfree` int(11) DEFAULT NULL, PRIMARY KEY (`mempool_id`), KEY `device_id` (`device_id`)) ENGINE=MyISAM DEFAULT CHARSET=utf8 COLLATE=utf8_bin ;
ALTER TABLE `storage` CHANGE `storage_size` `storage_size` BIGINT NOT NULL ,CHANGE `storage_used` `storage_used` BIGINT NOT NULL ,CHANGE `storage_free` `storage_free` BIGINT NOT NULL;
ALTER TABLE `mempools` CHANGE `mempool_used` `mempool_used` BIGINT( 20 ) NOT NULL , CHANGE `mempool_free` `mempool_free` BIGINT( 20 ) NOT NULL ,CHANGE `mempool_total` `mempool_total` BIGINT( 20 ) NOT NULL ,CHANGE `mempool_largestfree` `mempool_largestfree` BIGINT( 20 ) NULL DEFAULT NULL ,CHANGE `mempool_lowestfree` `mempool_lowestfree` BIGINT( 20 ) NULL DEFAULT NULL;
ALTER TABLE `juniAtmVp` MODIFY COLUMN `juniAtmVp_id` int(11) NOT NULL AUTO_INCREMENT, ADD PRIMARY KEY (`juniAtmVp_id`);