-- ZyXEL Communications Corporation
|
|
-- Private Enterprise MIB definition - Calvin Chai
|
|
-- 04/30/96
|
|
|
|
-- This file describes the ZyXEL Communications Corporation Enterprise MIB.
|
|
-- It includes object identifiers and object definitions for the ZyXEL
|
|
-- Enterprise MIB only, and should be used for compilation by a management
|
|
-- tool in order to extend the tool to support the ZyXEL MIB.
|
|
|
|
-- edited by Manfred Recla <support@europe.zyxel.com>
|
|
-- 2001/07/11
|
|
-- renamed "ZYXEL-MIB" into "ZyXEL-COE-MIB"
|
|
|
|
ZyXEL-COE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
enterprises, NetworkAddress, IpAddress, Counter
|
|
FROM RFC1155-SMI
|
|
PhysAddress
|
|
FROM RFC1213-MIB
|
|
OBJECT-TYPE
|
|
FROM RFC-1212
|
|
TRAP-TYPE
|
|
FROM RFC-1215;
|
|
|
|
DisplayString ::= OCTET STRING
|
|
|
|
-- tree structure
|
|
|
|
zyxel OBJECT IDENTIFIER ::= { enterprises 890 }
|
|
|
|
products OBJECT IDENTIFIER ::= { zyxel 1 }
|
|
|
|
prestige OBJECT IDENTIFIER ::= { products 2 }
|
|
mtu OBJECT IDENTIFIER ::= { products 3 }
|
|
dslam OBJECT IDENTIFIER ::= { products 4 }
|
|
systemTraps OBJECT IDENTIFIER ::= { products 999 }
|
|
|
|
-- prestige products
|
|
|
|
|
|
-- MTU products
|
|
aes-100 OBJECT IDENTIFIER ::= { mtu 1 }
|
|
pes-100 OBJECT IDENTIFIER ::= { mtu 2 }
|
|
ves-100 OBJECT IDENTIFIER ::= { mtu 3 }
|
|
shes-100 OBJECT IDENTIFIER ::= { mtu 4 }
|
|
p1600 OBJECT IDENTIFIER ::= { mtu 5 }
|
|
p1400 OBJECT IDENTIFIER ::= { mtu 6 }
|
|
p2100 OBJECT IDENTIFIER ::= { mtu 7 }
|
|
aes-100-1 OBJECT IDENTIFIER ::= { mtu 8 }
|
|
|
|
-- DSLAM products
|
|
zysam-1000 OBJECT IDENTIFIER ::= { dslam 1 }
|
|
zysam-1100 OBJECT IDENTIFIER ::= { dslam 2 }
|
|
zysam-1200 OBJECT IDENTIFIER ::= { dslam 3 }
|
|
zysam-2000 OBJECT IDENTIFIER ::= { dslam 4 }
|
|
|
|
-- System traps
|
|
|
|
problemCause OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The variable is the description of sytsem problem."
|
|
::= { systemTraps 1 }
|
|
|
|
systemTemperature OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The variable is the current temperature in Celsius of the system."
|
|
::= { systemTraps 2 }
|
|
|
|
reboot TRAP-TYPE
|
|
ENTERPRISE zyxel
|
|
VARIABLES {
|
|
problemCause
|
|
}
|
|
DESCRIPTION "Send a message to the manager that the system is going to reboot.
|
|
The variable is the reason why the system reboots."
|
|
::= 1
|
|
|
|
systemShutdown TRAP-TYPE
|
|
ENTERPRISE zyxel
|
|
VARIABLES {
|
|
problemCause
|
|
}
|
|
DESCRIPTION "Send a message to the manager that the system is going to shutdown.
|
|
The variable is the reason that causes the system to shutdown."
|
|
::= 2
|
|
|
|
overheat TRAP-TYPE
|
|
ENTERPRISE zyxel
|
|
VARIABLES {
|
|
systemTemperature
|
|
}
|
|
DESCRIPTION "Send a message to the manager that the system is overheated.
|
|
The variable in the binding list is the current temperature in Celsius
|
|
of the system."
|
|
::= 3
|
|
|
|
overheatOver TRAP-TYPE
|
|
ENTERPRISE zyxel
|
|
VARIABLES {
|
|
systemTemperature
|
|
}
|
|
DESCRIPTION "Send a message to the manager that the overheated condition is over.
|
|
The variable in the binding list is the current temperature in Celsius
|
|
of the system."
|
|
::= 4
|
|
|
|
|
|
|
|
|
|
|
|
END
|