-- ZyXEL Communications Corporation
|
|
-- Private Enterprise MIB definition
|
|
|
|
-- This file describes the ZyXEL Communications Corporation Enterprise MIB.
|
|
-- It contains ZyXEL products OIDs, and common managed objects.
|
|
|
|
-- $Log: zyxel-ES3124.mib $
|
|
-- Revision 1.1 2005/06/09 11:31:24 jennyhsu
|
|
-- Initial revision
|
|
--
|
|
|
|
|
|
ZYXEL-ES3124-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, Gauge32, Integer32, Unsigned32 FROM SNMPv2-SMI
|
|
enterprises FROM RFC1155-SMI
|
|
TEXTUAL-CONVENTION FROM SNMPv2-TC
|
|
|
|
OBJECT-TYPE
|
|
FROM SNMPv2-SMI -- RFC2578
|
|
RowStatus, DateAndTime, TruthValue, StorageType, PhysAddress
|
|
FROM SNMPv2-TC -- RFC2579
|
|
DisplayString
|
|
FROM RFC1213-MIB
|
|
EnabledStatus
|
|
FROM P-BRIDGE-MIB
|
|
PortList
|
|
FROM Q-BRIDGE-MIB
|
|
dot1dBasePort
|
|
FROM BRIDGE-MIB
|
|
InterfaceIndexOrZero -- RFC2863
|
|
FROM IF-MIB
|
|
SnmpAdminString
|
|
FROM SNMP-FRAMEWORK-MIB -- RFC2571
|
|
InetAddressType, InetAddress
|
|
FROM INET-ADDRESS-MIB -- RFC2851
|
|
OperationResponseStatus
|
|
FROM DISMAN-PING-MIB
|
|
IpAddress
|
|
FROM SNMPv2-SMI
|
|
|
|
NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
sysObjectID
|
|
FROM RFC1213-MIB;
|
|
|
|
zyxel OBJECT IDENTIFIER ::= { enterprises 890 }
|
|
products OBJECT IDENTIFIER ::= { zyxel 1 }
|
|
accessSwitch OBJECT IDENTIFIER ::= { products 5 }
|
|
esSeries OBJECT IDENTIFIER ::= { accessSwitch 8 }
|
|
es3124 OBJECT IDENTIFIER ::= { esSeries 12 }
|
|
|
|
|
|
-- sysInfo
|
|
sysInfo OBJECT IDENTIFIER ::= { es3124 1 }
|
|
|
|
sysSwPlatformMajorVers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SW platform major version, e.g. 3."
|
|
::= { sysInfo 1 }
|
|
|
|
sysSwPlatformMinorVers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SW platform minor version, e.g. 50."
|
|
::= { sysInfo 2 }
|
|
|
|
sysSwModelString OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Model letters, e.g. TJ"
|
|
::= { sysInfo 3 }
|
|
|
|
sysSwVersionControlNbr OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Version control number, e.g. 0."
|
|
::= { sysInfo 4 }
|
|
|
|
sysSwDay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SW compilation day, e.g. 19."
|
|
::= { sysInfo 5 }
|
|
|
|
sysSwMonth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SW compilation month, e.g. 8."
|
|
::= { sysInfo 6 }
|
|
|
|
sysSwYear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SW compilation year, e.g. 2004."
|
|
::= { sysInfo 7 }
|
|
|
|
sysHwMajorVers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HW major version number, e.g. 1."
|
|
::= { sysInfo 8 }
|
|
|
|
sysHwMinorVers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HW minor version number, e.g. 0."
|
|
::= { sysInfo 9 }
|
|
|
|
sysSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Serial number"
|
|
::= { sysInfo 10 }
|
|
|
|
-- rateLimitSetup
|
|
rateLimitSetup OBJECT IDENTIFIER ::= { es3124 2 }
|
|
|
|
rateLimitState OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ingress/egress rate limiting enabled/disabled for the switch."
|
|
::= { rateLimitSetup 1 }
|
|
|
|
-- rateLimitPortTable
|
|
|
|
rateLimitPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RateLimitPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { rateLimitSetup 2 }
|
|
|
|
rateLimitPortEntry OBJECT-TYPE
|
|
SYNTAX RateLimitPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry in rateLimitPortTable."
|
|
INDEX { dot1dBasePort }
|
|
::= { rateLimitPortTable 1 }
|
|
|
|
RateLimitPortEntry ::=
|
|
SEQUENCE {
|
|
rateLimitPortState EnabledStatus,
|
|
rateLimitPortIngRate INTEGER,
|
|
rateLimitPortEgrRate INTEGER
|
|
}
|
|
|
|
rateLimitPortState OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ingress/egress rate limiting enabled/disabled on the port."
|
|
::= { rateLimitPortEntry 1 }
|
|
|
|
rateLimitPortIngRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ingress rate in Kbit/s. The granularity of FE port is between 1 and 100000. For GE port, the granularity is between 1 and 1000000."
|
|
::= { rateLimitPortEntry 2 }
|
|
|
|
rateLimitPortEgrRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Egress rate in Mbit/s. The granularity of FE port is between 1 and 100. For GE port, the granularity is between 1 and 1000."
|
|
::= { rateLimitPortEntry 3 }
|
|
|
|
-- brLimitSetup
|
|
brLimitSetup OBJECT IDENTIFIER ::= { es3124 3 }
|
|
|
|
brLimitState OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Broadcast/multicast/DLF rate limiting enabled/disabled for the switch."
|
|
::= { brLimitSetup 1 }
|
|
|
|
-- brLimitPortTable
|
|
brLimitPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BrLimitPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { brLimitSetup 2 }
|
|
|
|
brLimitPortEntry OBJECT-TYPE
|
|
SYNTAX BrLimitPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry in brLimitPortTable."
|
|
INDEX { dot1dBasePort }
|
|
::= { brLimitPortTable 1 }
|
|
|
|
BrLimitPortEntry ::=
|
|
SEQUENCE {
|
|
brLimitPortBrState EnabledStatus,
|
|
brLimitPortBrRate INTEGER,
|
|
brLimitPortMcState EnabledStatus,
|
|
brLimitPortMcRate INTEGER,
|
|
brLimitPortDlfState EnabledStatus,
|
|
brLimitPortDlfRate INTEGER
|
|
}
|
|
|
|
brLimitPortBrState OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Broadcast rate limiting enabled/disabled on the port."
|
|
::= { brLimitPortEntry 1 }
|
|
|
|
brLimitPortBrRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allowed broadcast rate in pkts/s. For FE port,
|
|
the maximum value is 148800. For GE port, the maximum value is 262143."
|
|
::= { brLimitPortEntry 2 }
|
|
|
|
brLimitPortMcState OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Multicast rate limiting enabled/disabled on the port."
|
|
::= { brLimitPortEntry 3 }
|
|
|
|
brLimitPortMcRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"AAllowed mullticast rate in pkts/s. For FE port,
|
|
the maximum value is 148800. For GE port, the maximum value is 262143."
|
|
::= { brLimitPortEntry 4 }
|
|
|
|
brLimitPortDlfState OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Destination lookup failure frames rate limiting enabled/disabled on the port."
|
|
::= { brLimitPortEntry 5 }
|
|
|
|
brLimitPortDlfRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allowed destination lookup failure frames rate in pkts/s.
|
|
For FE port, the maximum value is 148800. For GE port, the maximum value is 262143."
|
|
::= { brLimitPortEntry 6 }
|
|
|
|
-- portSecuritySetup
|
|
portSecuritySetup OBJECT IDENTIFIER ::= { es3124 4 }
|
|
|
|
portSecurityState OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { portSecuritySetup 1 }
|
|
|
|
portSecurityPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PortSecurityPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { portSecuritySetup 2 }
|
|
|
|
portSecurityPortEntry OBJECT-TYPE
|
|
SYNTAX PortSecurityPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry in portSecurityPortTable."
|
|
INDEX { dot1dBasePort }
|
|
::= { portSecurityPortTable 1 }
|
|
|
|
PortSecurityPortEntry ::=
|
|
SEQUENCE {
|
|
portSecurityPortState EnabledStatus,
|
|
portSecurityPortLearnState EnabledStatus,
|
|
portSecurityPortCount INTEGER
|
|
}
|
|
|
|
portSecurityPortState OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port Security enabled/disabled on the port.
|
|
Active(1) means this port only accept frames from static MAC addresses that are configured for the port,
|
|
and dynamic MAC address frames up to the number specified by portSecurityPortCount object."
|
|
::= { portSecurityPortEntry 1 }
|
|
|
|
portSecurityPortLearnState OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MAC address learning enabled/disable on the port."
|
|
::= { portSecurityPortEntry 2 }
|
|
|
|
portSecurityPortCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of (dynamic) MAC addresses that may be learned on the port."
|
|
::= { portSecurityPortEntry 3 }
|
|
|
|
portSecurityMacFreeze OBJECT-TYPE
|
|
SYNTAX PortList
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry is used to execute MacFreeze action to port.
|
|
It's meaningless while reading this entry."
|
|
::= { portSecuritySetup 3 }
|
|
|
|
-- vlanTrunkPortTable
|
|
vlanTrunkSetup OBJECT IDENTIFIER ::= { es3124 5 }
|
|
|
|
vlanTrunkPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF VlanTrunkPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { vlanTrunkSetup 1 }
|
|
|
|
vlanTrunkPortEntry OBJECT-TYPE
|
|
SYNTAX VlanTrunkPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry in vlanTrunkPortTable."
|
|
INDEX { dot1dBasePort }
|
|
::= { vlanTrunkPortTable 1 }
|
|
|
|
VlanTrunkPortEntry ::=
|
|
SEQUENCE {
|
|
vlanTrunkPortState EnabledStatus
|
|
}
|
|
|
|
vlanTrunkPortState OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"VlanTrunking enabled/disabled on the port.
|
|
Active(1) to allow frames belonging to unknown
|
|
VLAN groups to pass through the switch."
|
|
::= { vlanTrunkPortEntry 1 }
|
|
|
|
-- ctlProtTransSetup
|
|
ctlProtTransSetup OBJECT IDENTIFIER ::= { es3124 6 }
|
|
|
|
ctlProtTransState OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bridge control protocol transparency enabled/disabled for the switch"
|
|
::= { ctlProtTransSetup 1 }
|
|
|
|
-- ctlProtTransTunnelPortTable
|
|
|
|
ctlProtTransTunnelPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtlProtTransTunnelPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { ctlProtTransSetup 2 }
|
|
|
|
ctlProtTransTunnelPortEntry OBJECT-TYPE
|
|
SYNTAX CtlProtTransTunnelPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry in ctlProtTransTunnelPortTable."
|
|
INDEX { dot1dBasePort }
|
|
::= { ctlProtTransTunnelPortTable 1 }
|
|
|
|
CtlProtTransTunnelPortEntry ::=
|
|
SEQUENCE {
|
|
ctlProtTransTunnelMode INTEGER
|
|
}
|
|
|
|
ctlProtTransTunnelMode OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
peer(0),
|
|
tunnel(1),
|
|
discard(2),
|
|
network(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bridge control protocol transparency mode for the port.
|
|
Modes: Peer(0), Tunnel(1), Discard(2), Network(3)"
|
|
::= { ctlProtTransTunnelPortEntry 1 }
|
|
|
|
-- vlanStackSetup
|
|
vlanStackSetup OBJECT IDENTIFIER ::= { es3124 7 }
|
|
|
|
vlanStackState OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"VLAN Stacking enabled/disabled for the switch."
|
|
::= { vlanStackSetup 1 }
|
|
|
|
vlanStackTpid OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP TPID in hex format, e.g. 8100."
|
|
::= { vlanStackSetup 2 }
|
|
|
|
-- vlanStackPortTable
|
|
|
|
vlanStackPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF VlanStackPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { vlanStackSetup 3 }
|
|
|
|
vlanStackPortEntry OBJECT-TYPE
|
|
SYNTAX VlanStackPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry in vlanStackPortTable."
|
|
INDEX { dot1dBasePort }
|
|
::= { vlanStackPortTable 1 }
|
|
|
|
VlanStackPortEntry ::=
|
|
SEQUENCE {
|
|
vlanStackPortMode INTEGER,
|
|
vlanStackPortVid INTEGER,
|
|
vlanStackPortPrio INTEGER
|
|
}
|
|
|
|
vlanStackPortMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(1),
|
|
access(2),
|
|
tunnel(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the port. Set Normal to have the switch ignore frames received
|
|
(or transmitted) on this port with VLAN stacking tags.
|
|
Anything you configure in SPVID and Priority are ignored.
|
|
Set Access mode to have the switch add the SP TPID tag to all incoming
|
|
frames received on this port. Set Access mode for ingress ports at the
|
|
edge of the service provider's network. Set Tunnel mode (available for
|
|
Gigabit ports only) for egress ports at the edge of the service provider's
|
|
network. In order to support VLAN stacking on a port, the port must be able
|
|
to allow frames of 1526 Bytes (1522 Bytes + 4 Bytes for the second tag)
|
|
to pass through it. normal (1), Access (2), tunnel (3)"
|
|
::= { vlanStackPortEntry 1 }
|
|
|
|
vlanStackPortVid OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"VLAN ID used in service provider tag."
|
|
::= { vlanStackPortEntry 2 }
|
|
|
|
vlanStackPortPrio OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
prioriry-0(0),
|
|
prioriry-1(1),
|
|
prioriry-2(2),
|
|
prioriry-3(3),
|
|
prioriry-4(4),
|
|
prioriry-5(5),
|
|
prioriry-6(6),
|
|
prioriry-7(7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Priority value for service provider tag.
|
|
0 is the lowest priority level and 7 is the highest."
|
|
::= { vlanStackPortEntry 3 }
|
|
|
|
-- radius8021xSetup
|
|
radius8021xSetup OBJECT IDENTIFIER ::= { es3124 8 }
|
|
|
|
radiusLoginPrecedence OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"1. Local Only
|
|
2. Local then RADIUS
|
|
3. RADIUS Only"
|
|
::= { radius8021xSetup 1 }
|
|
|
|
-- radiusAnd8021xServer
|
|
|
|
radiusAnd8021xServer OBJECT IDENTIFIER ::= { radius8021xSetup 2 }
|
|
|
|
radiusIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP address of the RADIUS server."
|
|
::= { radiusAnd8021xServer 1 }
|
|
|
|
radiusUdpPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UDP port of the RADIUS server."
|
|
::= { radiusAnd8021xServer 2 }
|
|
|
|
radiusSharedSecret OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Shared secret used for RADIUS and network element authentication."
|
|
::= { radiusAnd8021xServer 3 }
|
|
|
|
-- portAuthState
|
|
portAuthState OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"802.1x port authentication enabled/disabled for the switch."
|
|
::= { radius8021xSetup 3 }
|
|
|
|
|
|
-- 8021xPortAuthTable
|
|
|
|
portAuthTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PortAuthEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { radius8021xSetup 4 }
|
|
|
|
portAuthEntry OBJECT-TYPE
|
|
SYNTAX PortAuthEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry in portAuthTable."
|
|
INDEX { dot1dBasePort }
|
|
::= { portAuthTable 1 }
|
|
|
|
PortAuthEntry ::=
|
|
SEQUENCE {
|
|
portAuthEntryState EnabledStatus,
|
|
portReAuthEntryState EnabledStatus,
|
|
portReAuthEntryTimer INTEGER
|
|
}
|
|
|
|
portAuthEntryState OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"802.1x port authentication enabled or disabled on the port."
|
|
::= { portAuthEntry 1 }
|
|
|
|
portReAuthEntryState OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"802.1x port re-authentication enabled or disabled on the port."
|
|
::= { portAuthEntry 2 }
|
|
|
|
portReAuthEntryTimer OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Re-authentication timer in seconds."
|
|
::= { portAuthEntry 3 }
|
|
|
|
-- hardwareInfo
|
|
hwMonitorInfo OBJECT IDENTIFIER ::= { es3124 9 }
|
|
|
|
-- fabRpmTable
|
|
|
|
fanRpmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FanRpmEntry
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { hwMonitorInfo 1 }
|
|
|
|
fanRpmEntry OBJECT-TYPE
|
|
SYNTAX FanRpmEntry
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in fanRpmTable."
|
|
INDEX { fanRpmIndex }
|
|
::= { fanRpmTable 1 }
|
|
|
|
FanRpmEntry ::=
|
|
SEQUENCE {
|
|
fanRpmIndex INTEGER,
|
|
fanRpmCurValue INTEGER,
|
|
fanRpmMaxValue INTEGER,
|
|
fanRpmMinValue INTEGER,
|
|
fanRpmLowThresh INTEGER,
|
|
fanRpmDescr DisplayString
|
|
}
|
|
|
|
fanRpmIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of FAN."
|
|
::= { fanRpmEntry 1 }
|
|
|
|
fanRpmCurValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current speed in Revolutions Per Minute (RPM) on the fan."
|
|
::= { fanRpmEntry 2 }
|
|
|
|
fanRpmMaxValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum speed measured in Revolutions Per Minute (RPM) on the fan."
|
|
::= { fanRpmEntry 3 }
|
|
|
|
fanRpmMinValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum speed measured in Revolutions Per Minute (RPM) on the fan."
|
|
::= { fanRpmEntry 4 }
|
|
|
|
fanRpmLowThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum speed at which a normal fan should work."
|
|
::= { fanRpmEntry 5 }
|
|
|
|
fanRpmDescr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"'Normal' indicates that this fan is functioning above the minimum speed.
|
|
'Error' indicates that this fan is functioning below the minimum speed."
|
|
::= { fanRpmEntry 6 }
|
|
|
|
-- tempTable
|
|
|
|
tempTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TempEntry
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { hwMonitorInfo 2 }
|
|
|
|
tempEntry OBJECT-TYPE
|
|
SYNTAX TempEntry
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in tempTable."
|
|
INDEX { tempIndex }
|
|
::= { tempTable 1 }
|
|
|
|
TempEntry ::=
|
|
SEQUENCE {
|
|
tempIndex INTEGER,
|
|
tempCurValue INTEGER,
|
|
tempMaxValue INTEGER,
|
|
tempMinValue INTEGER,
|
|
tempHighThresh INTEGER,
|
|
tempDescr DisplayString
|
|
}
|
|
|
|
tempIndex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
mac (1),
|
|
cpu (2),
|
|
phy (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of temperature unit. 1:MAC, 2:CPU, 3:PHY"
|
|
::= { tempEntry 1 }
|
|
|
|
tempCurValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current temperature measured at this sensor."
|
|
::= { tempEntry 2 }
|
|
|
|
tempMaxValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum temperature measured at this sensor."
|
|
::= { tempEntry 3 }
|
|
|
|
tempMinValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum temperature measured at this sensor."
|
|
::= { tempEntry 4 }
|
|
|
|
tempHighThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper temperature limit at this sensor."
|
|
::= { tempEntry 5 }
|
|
|
|
tempDescr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"'Normal' indicates temperatures below the threshold and 'Error' for those above."
|
|
::= { tempEntry 6 }
|
|
|
|
-- voltageTable
|
|
|
|
voltageTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF VoltageEntry
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { hwMonitorInfo 3 }
|
|
|
|
voltageEntry OBJECT-TYPE
|
|
SYNTAX VoltageEntry
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in voltageTable."
|
|
INDEX { voltageIndex }
|
|
::= { voltageTable 1 }
|
|
|
|
VoltageEntry ::=
|
|
SEQUENCE {
|
|
voltageIndex INTEGER,
|
|
voltageCurValue INTEGER,
|
|
voltageMaxValue INTEGER,
|
|
voltageMinValue INTEGER,
|
|
voltageNominalValue INTEGER,
|
|
voltageLowThresh INTEGER,
|
|
voltageDescr DisplayString
|
|
}
|
|
|
|
voltageIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of voltage."
|
|
::= { voltageEntry 1 }
|
|
|
|
voltageCurValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current voltage reading."
|
|
::= { voltageEntry 2 }
|
|
|
|
voltageMaxValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum voltage measured at this point."
|
|
::= { voltageEntry 3 }
|
|
|
|
voltageMinValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum voltage measured at this point."
|
|
::= { voltageEntry 4 }
|
|
|
|
voltageNominalValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The normal voltage at wchich the switch work."
|
|
::= { voltageEntry 5 }
|
|
|
|
voltageLowThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum voltage at which the switch should work."
|
|
::= { voltageEntry 6 }
|
|
|
|
voltageDescr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"'Normal' indicates that the voltage is within an acceptable operating range
|
|
at this point; otherwise 'Error' is displayed."
|
|
::= { voltageEntry 7 }
|
|
|
|
-- snmpSetup
|
|
snmpSetup OBJECT IDENTIFIER ::= { es3124 10 }
|
|
|
|
snmpGetCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { snmpSetup 1 }
|
|
|
|
snmpSetCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { snmpSetup 2 }
|
|
|
|
snmpTrapCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { snmpSetup 3 }
|
|
|
|
-- snmpTrapDestTable
|
|
snmpTrapDestTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SnmpTrapDestEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { snmpSetup 4 }
|
|
|
|
snmpTrapDestEntry OBJECT-TYPE
|
|
SYNTAX SnmpTrapDestEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry in snmpTrapDestTable."
|
|
INDEX { snmpTrapDestIP }
|
|
::= { snmpTrapDestTable 1 }
|
|
|
|
SnmpTrapDestEntry ::=
|
|
SEQUENCE {
|
|
snmpTrapDestIP IpAddress,
|
|
snmpTrapDestRowStatus RowStatus
|
|
}
|
|
|
|
snmpTrapDestIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of trap destination."
|
|
::= { snmpTrapDestEntry 1 }
|
|
|
|
snmpTrapDestRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
ACCESS read-create
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { snmpTrapDestEntry 2 }
|
|
|
|
|
|
-- dateTimeServerSetup
|
|
dateTimeServerSetup OBJECT IDENTIFIER ::= { es3124 11 }
|
|
|
|
dateTimeServerType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
daytime(2),
|
|
time(3),
|
|
ntp(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time service protocol."
|
|
::= { dateTimeServerSetup 1 }
|
|
|
|
dateTimeServerIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of time server."
|
|
::= { dateTimeServerSetup 2 }
|
|
|
|
dateTimeZone OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time difference between UTC. Ex: +01"
|
|
::= { dateTimeServerSetup 3 }
|
|
|
|
dateTimeNewDateYear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The new date in year."
|
|
::= { dateTimeServerSetup 4 }
|
|
|
|
dateTimeNewDateMonth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The new date in month."
|
|
::= { dateTimeServerSetup 5 }
|
|
|
|
dateTimeNewDateDay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The new date in day."
|
|
::= { dateTimeServerSetup 6 }
|
|
|
|
dateTimeNewTimeHour OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The new time in hour."
|
|
::= { dateTimeServerSetup 7 }
|
|
|
|
dateTimeNewTimeMinute OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The new time in minute."
|
|
::= { dateTimeServerSetup 8 }
|
|
|
|
dateTimeNewTimeSecond OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The new time in second."
|
|
::= { dateTimeServerSetup 9 }
|
|
|
|
-- sysMgmt
|
|
sysMgmt OBJECT IDENTIFIER ::= { es3124 12 }
|
|
|
|
sysMgmtConfigSave OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
config-1(1),
|
|
config-2(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If setting value is given, the variable write index will be set and running-config will be written to the assigned configuration file.
|
|
If not, running-config will be written to the booting one."
|
|
::= { sysMgmt 1 }
|
|
|
|
sysMgmtBootupConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
config-1(1),
|
|
config-2(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The setting value (read index) will be written into non-volatile memory.
|
|
While rebooting, the variable write index is equal to read index initially.
|
|
You can change the value of write index by CLI / MIB."
|
|
::= { sysMgmt 2 }
|
|
|
|
sysMgmtReboot OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nothing(0),
|
|
reboot(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reboot switch from SNMP. 1:Reboot, 0:Nothing"
|
|
::= { sysMgmt 3 }
|
|
|
|
sysMgmtDefaultConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nothing(0),
|
|
reset-to-default(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Erase running config and reset to default."
|
|
::= { sysMgmt 4 }
|
|
|
|
sysMgmtLastActionStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
success(1),
|
|
fail(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Display status of last mgmt action."
|
|
::= { sysMgmt 5 }
|
|
|
|
sysMgmtSystemStatus OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
sysAlarmDetected(0),
|
|
sysTemperatureError(1),
|
|
sysFanRPMError(2),
|
|
sysVoltageRangeError(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable indicates the status of the system.
|
|
The sysMgmtAlarmStatus is a bit map represented
|
|
a sum, therefore, it can represent multiple defects
|
|
simultaneously. The sysNoDefect should be set if and only if
|
|
no other flag is set.
|
|
|
|
The various bit positions are:
|
|
0 sysAlarmDetected
|
|
1 sysTemperatureError
|
|
2 sysFanRPMError
|
|
3 sysVoltageRangeError"
|
|
::= { sysMgmt 6 }
|
|
|
|
-- layer2Setup
|
|
layer2Setup OBJECT IDENTIFIER ::= { es3124 13 }
|
|
|
|
vlanTypeSetup OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dot1Q(1),
|
|
port-based(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { layer2Setup 1 }
|
|
|
|
igmpSnoopingStateSetup OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { layer2Setup 2 }
|
|
|
|
tagVlanPortIsolationState OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { layer2Setup 3 }
|
|
|
|
stpState OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { layer2Setup 4 }
|
|
|
|
|
|
-- ipSetup
|
|
ipSetup OBJECT IDENTIFIER ::= { es3124 14 }
|
|
|
|
dnsIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { ipSetup 1 }
|
|
|
|
defaultMgmt OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
in-band(0),
|
|
out-of-band(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { ipSetup 2 }
|
|
|
|
inbandIpSetup OBJECT IDENTIFIER ::= { ipSetup 3 }
|
|
|
|
inbandIpType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dhcp-client(0),
|
|
static-ip(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { inbandIpSetup 1 }
|
|
|
|
inbandVid OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { inbandIpSetup 2 }
|
|
|
|
inbandStaticIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { inbandIpSetup 3 }
|
|
|
|
inbandStaticSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { inbandIpSetup 4 }
|
|
|
|
inbandStaticGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { inbandIpSetup 5 }
|
|
|
|
outOfBandIpSetup OBJECT IDENTIFIER ::= { ipSetup 4 }
|
|
|
|
outOfBandIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { outOfBandIpSetup 1 }
|
|
|
|
outOfBandSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { outOfBandIpSetup 2 }
|
|
|
|
outOfBandGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { outOfBandIpSetup 3 }
|
|
|
|
-- inbandIpTable
|
|
maxNumOfInbandIp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { ipSetup 5 }
|
|
|
|
inbandIpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF InbandIpEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { ipSetup 6 }
|
|
|
|
inbandIpEntry OBJECT-TYPE
|
|
SYNTAX InbandIpEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry in inbandIpTable."
|
|
INDEX { inbandEntryIp, inbandEntryVid }
|
|
::= { inbandIpTable 1 }
|
|
|
|
InbandIpEntry ::=
|
|
SEQUENCE {
|
|
inbandEntryIp IpAddress,
|
|
inbandEntrySubnetMask IpAddress,
|
|
inbandEntryGateway IpAddress,
|
|
inbandEntryVid INTEGER,
|
|
inbandEntryManageable EnabledStatus,
|
|
inbandEntryRowStatus RowStatus
|
|
}
|
|
|
|
inbandEntryIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { inbandIpEntry 1 }
|
|
|
|
inbandEntrySubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { inbandIpEntry 2 }
|
|
|
|
inbandEntryGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { inbandIpEntry 3 }
|
|
|
|
inbandEntryVid OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { inbandIpEntry 4 }
|
|
|
|
inbandEntryManageable OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { inbandIpEntry 5 }
|
|
|
|
inbandEntryRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
ACCESS read-create
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { inbandIpEntry 6 }
|
|
|
|
-- filterSetup
|
|
filterSetup OBJECT IDENTIFIER ::= { es3124 15 }
|
|
|
|
-- filterTable
|
|
filterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FilterEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { filterSetup 1 }
|
|
|
|
filterEntry OBJECT-TYPE
|
|
SYNTAX FilterEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry in filterTable."
|
|
INDEX { filterMacAddr, filterVid }
|
|
::= { filterTable 1 }
|
|
|
|
FilterEntry ::=
|
|
SEQUENCE {
|
|
filterName DisplayString,
|
|
filterActionState INTEGER,
|
|
filterMacAddr PhysAddress,
|
|
filterVid INTEGER,
|
|
filterRowStatus RowStatus
|
|
}
|
|
|
|
filterName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { filterEntry 1 }
|
|
|
|
filterActionState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
discard-source(1),
|
|
discard-destination(2),
|
|
both(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { filterEntry 2 }
|
|
|
|
filterMacAddr OBJECT-TYPE
|
|
SYNTAX PhysAddress
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { filterEntry 3 }
|
|
|
|
filterVid OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { filterEntry 4 }
|
|
|
|
filterRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
ACCESS read-create
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { filterEntry 5 }
|
|
|
|
-- mirrorSetup
|
|
mirrorSetup OBJECT IDENTIFIER ::= { es3124 16 }
|
|
|
|
-- mirrorState
|
|
mirrorState OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { mirrorSetup 1 }
|
|
|
|
mirrorMonitorPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { mirrorSetup 2 }
|
|
|
|
-- mirrorTable
|
|
|
|
mirrorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MirrorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { mirrorSetup 3 }
|
|
|
|
mirrorEntry OBJECT-TYPE
|
|
SYNTAX MirrorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry in mirrorTable."
|
|
INDEX { dot1dBasePort }
|
|
::= { mirrorTable 1 }
|
|
|
|
MirrorEntry ::=
|
|
SEQUENCE {
|
|
mirrorMirroredState EnabledStatus,
|
|
mirrorDirection INTEGER
|
|
}
|
|
|
|
mirrorMirroredState OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { mirrorEntry 1 }
|
|
|
|
mirrorDirection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ingress(0),
|
|
egress(1),
|
|
both(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { mirrorEntry 2 }
|
|
|
|
|
|
-- aggrSetup
|
|
aggrSetup OBJECT IDENTIFIER ::= { es3124 17 }
|
|
|
|
aggrState OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { aggrSetup 1 }
|
|
|
|
aggrSystemPriority OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { aggrSetup 2 }
|
|
|
|
-- aggrGroupTable
|
|
|
|
aggrGroupTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AggrGroupEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { aggrSetup 3 }
|
|
|
|
aggrGroupEntry OBJECT-TYPE
|
|
SYNTAX AggrGroupEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry in aggrGroupTable."
|
|
INDEX { aggrGroupIndex }
|
|
::= { aggrGroupTable 1 }
|
|
|
|
AggrGroupEntry ::=
|
|
SEQUENCE {
|
|
aggrGroupIndex INTEGER,
|
|
aggrGroupState EnabledStatus,
|
|
aggrGroupDynamicState EnabledStatus
|
|
}
|
|
|
|
aggrGroupIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { aggrGroupEntry 1 }
|
|
|
|
aggrGroupState OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { aggrGroupEntry 2 }
|
|
|
|
aggrGroupDynamicState OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { aggrGroupEntry 3 }
|
|
|
|
-- aggrPortTable
|
|
|
|
aggrPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AggrPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { aggrSetup 4 }
|
|
|
|
aggrPortEntry OBJECT-TYPE
|
|
SYNTAX AggrPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry in aggrPortTable."
|
|
INDEX { dot1dBasePort }
|
|
::= { aggrPortTable 1 }
|
|
|
|
AggrPortEntry ::=
|
|
SEQUENCE {
|
|
aggrPortGroup INTEGER,
|
|
aggrPortDynamicStateTimeout INTEGER
|
|
}
|
|
|
|
aggrPortGroup OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
t1(1),
|
|
t2(2),
|
|
t3(3),
|
|
t4(4),
|
|
t5(5),
|
|
t6(6)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { aggrPortEntry 1 }
|
|
|
|
aggrPortDynamicStateTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { aggrPortEntry 2 }
|
|
|
|
|
|
-- accessCtlSetup
|
|
accessCtlSetup OBJECT IDENTIFIER ::= { es3124 18 }
|
|
|
|
-- accessCtlTable
|
|
|
|
accessCtlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AccessCtlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { accessCtlSetup 1 }
|
|
|
|
accessCtlEntry OBJECT-TYPE
|
|
SYNTAX AccessCtlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry in accessCtlTable."
|
|
INDEX { accessCtlService }
|
|
::= { accessCtlTable 1 }
|
|
|
|
AccessCtlEntry ::=
|
|
SEQUENCE {
|
|
accessCtlService INTEGER,
|
|
accessCtlEnable EnabledStatus,
|
|
accessCtlServicePort INTEGER,
|
|
accessCtlTimeout INTEGER
|
|
}
|
|
|
|
accessCtlService OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
telnet(1),
|
|
ssh(2),
|
|
ftp(3),
|
|
http(4),
|
|
https(5),
|
|
icmp(6),
|
|
snmp(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { accessCtlEntry 1 }
|
|
|
|
accessCtlEnable OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { accessCtlEntry 2 }
|
|
|
|
accessCtlServicePort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { accessCtlEntry 3 }
|
|
|
|
accessCtlTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { accessCtlEntry 4 }
|
|
|
|
-- securedClientTable
|
|
securedClientTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SecuredClientEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { accessCtlSetup 2 }
|
|
|
|
securedClientEntry OBJECT-TYPE
|
|
SYNTAX SecuredClientEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry in securedClientTable."
|
|
INDEX { securedClientIndex }
|
|
::= { securedClientTable 1 }
|
|
|
|
SecuredClientEntry ::=
|
|
SEQUENCE {
|
|
securedClientIndex INTEGER,
|
|
securedClientEnable EnabledStatus,
|
|
securedClientStartIp IpAddress,
|
|
securedClientEndIp IpAddress,
|
|
securedClientService BITS
|
|
}
|
|
|
|
securedClientIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { securedClientEntry 1 }
|
|
|
|
securedClientEnable OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { securedClientEntry 2 }
|
|
|
|
securedClientStartIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { securedClientEntry 3 }
|
|
|
|
securedClientEndIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { securedClientEntry 4 }
|
|
|
|
securedClientService OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
telnet(0),
|
|
ftp(1),
|
|
http(2),
|
|
icmp(3),
|
|
snmp(4),
|
|
ssh(5),
|
|
https(6)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { securedClientEntry 5 }
|
|
|
|
-- queuingMethodSetup
|
|
queuingMethodSetup OBJECT IDENTIFIER ::= { es3124 19 }
|
|
|
|
queuingMethodType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
strictly-priority(0),
|
|
weighted-fair-scheduling(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { queuingMethodSetup 1 }
|
|
|
|
-- portQueuingMethodTable
|
|
portQueuingMethodTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PortQueuingMethodEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { queuingMethodSetup 2 }
|
|
|
|
portQueuingMethodEntry OBJECT-TYPE
|
|
SYNTAX PortQueuingMethodEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry in portQueuingMethodTable."
|
|
INDEX { dot1dBasePort, portQueuingMethodQueue }
|
|
::= {portQueuingMethodTable 1}
|
|
|
|
PortQueuingMethodEntry ::=
|
|
SEQUENCE {
|
|
portQueuingMethodQueue INTEGER,
|
|
portQueuingMethodWeight INTEGER
|
|
}
|
|
|
|
portQueuingMethodQueue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"0...7"
|
|
::= { portQueuingMethodEntry 1 }
|
|
|
|
portQueuingMethodWeight OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"0...100"
|
|
::= { portQueuingMethodEntry 2 }
|
|
|
|
-- dhcpSetup
|
|
dhcpSetup OBJECT IDENTIFIER ::= { es3124 20 }
|
|
|
|
dhcpRelay OBJECT IDENTIFIER ::= { dhcpSetup 1 }
|
|
|
|
dhcpRelayEnable OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { dhcpRelay 1 }
|
|
|
|
dhcpRelayOption82Enable OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { dhcpRelay 2 }
|
|
|
|
dhcpRelayInfoEnable OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { dhcpRelay 3 }
|
|
|
|
dhcpRelayInfoData OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { dhcpRelay 4 }
|
|
|
|
-- dhcpRemoteServer
|
|
|
|
maxNumberOfDhcpRemoteServer OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { dhcpRelay 5 }
|
|
|
|
-- dhcpRemoteServerTable
|
|
dhcpRemoteServerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DhcpRemoteServerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { dhcpRelay 6 }
|
|
|
|
dhcpRemoteServerEntry OBJECT-TYPE
|
|
SYNTAX DhcpRemoteServerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry in dhcpRemoteServerTable."
|
|
INDEX { dhcpRemoteServerIp }
|
|
::= { dhcpRemoteServerTable 1 }
|
|
|
|
DhcpRemoteServerEntry ::=
|
|
SEQUENCE {
|
|
dhcpRemoteServerIp IpAddress,
|
|
dhcpRemoteServerRowStatus RowStatus
|
|
}
|
|
|
|
dhcpRemoteServerIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { dhcpRemoteServerEntry 1 }
|
|
|
|
dhcpRemoteServerRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
ACCESS read-create
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { dhcpRemoteServerEntry 2 }
|
|
|
|
-- staticRouteSetup
|
|
staticRouteSetup OBJECT IDENTIFIER ::= { es3124 21 }
|
|
|
|
maxNumberOfStaticRoutes OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { staticRouteSetup 1 }
|
|
|
|
-- staticRouteTable
|
|
staticRouteTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF StaticRouteEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { staticRouteSetup 2 }
|
|
|
|
staticRouteEntry OBJECT-TYPE
|
|
SYNTAX StaticRouteEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry in staticRouteTable."
|
|
INDEX { staticRouteIp, staticRouteMask }
|
|
::= { staticRouteTable 1 }
|
|
|
|
StaticRouteEntry ::=
|
|
SEQUENCE {
|
|
staticRouteName DisplayString,
|
|
staticRouteIp IpAddress,
|
|
staticRouteMask IpAddress,
|
|
staticRouteGateway IpAddress,
|
|
staticRouteMetric INTEGER,
|
|
staticRouteRowStatus RowStatus
|
|
}
|
|
|
|
staticRouteName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { staticRouteEntry 1 }
|
|
|
|
staticRouteIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { staticRouteEntry 2 }
|
|
|
|
staticRouteMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { staticRouteEntry 3 }
|
|
|
|
staticRouteGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { staticRouteEntry 4 }
|
|
|
|
staticRouteMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { staticRouteEntry 5 }
|
|
|
|
staticRouteRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
ACCESS read-create
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { staticRouteEntry 6 }
|
|
|
|
-- arpInfo
|
|
arpInfo OBJECT IDENTIFIER ::= { es3124 22 }
|
|
|
|
-- arpTable
|
|
arpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ArpEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { arpInfo 1 }
|
|
|
|
arpEntry OBJECT-TYPE
|
|
SYNTAX ArpEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry in arpTable."
|
|
INDEX { arpIndex }
|
|
::= { arpTable 1 }
|
|
|
|
ArpEntry ::=
|
|
SEQUENCE {
|
|
arpIndex INTEGER,
|
|
arpIpAddr IpAddress,
|
|
arpMacAddr PhysAddress,
|
|
arpMacVid INTEGER,
|
|
arpType INTEGER
|
|
}
|
|
|
|
arpIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { arpEntry 1 }
|
|
|
|
arpIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { arpEntry 2 }
|
|
|
|
arpMacAddr OBJECT-TYPE
|
|
SYNTAX PhysAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { arpEntry 3 }
|
|
|
|
arpMacVid OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { arpEntry 4 }
|
|
|
|
arpType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { arpEntry 5 }
|
|
|
|
-- pltMgmt
|
|
pltMgmt OBJECT IDENTIFIER ::= { es3124 23 }
|
|
|
|
-- pltCtlTable
|
|
|
|
pltCtlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PltCtlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { pltMgmt 1 }
|
|
|
|
pltCtlEntry OBJECT-TYPE
|
|
SYNTAX PltCtlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry in pltCtlTable."
|
|
INDEX { pltCtlInstType, pltCtlInstId }
|
|
::= { pltCtlTable 1 }
|
|
|
|
PltCtlEntry ::=
|
|
SEQUENCE {
|
|
pltCtlInstType INTEGER,
|
|
pltCtlInstId INTEGER,
|
|
pltCtlIpAddr IpAddress,
|
|
pltCtlMask IpAddress,
|
|
pltCtlGw IpAddress,
|
|
pltCtlRowStatus RowStatus
|
|
}
|
|
|
|
pltCtlInstType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
vlan (1)
|
|
}
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of the service instance that is tested.
|
|
1: VLAN
|
|
"
|
|
::= { pltCtlEntry 1 }
|
|
|
|
pltCtlInstId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ID of the service instance that is tested."
|
|
::= { pltCtlEntry 2 }
|
|
|
|
pltCtlIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-create
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of this PLT stack instance."
|
|
::= { pltCtlEntry 3 }
|
|
|
|
pltCtlMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-create
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP subnet mask of this PLT stack instance."
|
|
::= { pltCtlEntry 4 }
|
|
|
|
pltCtlGw OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-create
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Default gateway IP address of this PLT stack instance."
|
|
::= { pltCtlEntry 5 }
|
|
|
|
pltCtlRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
ACCESS read-create
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object allows entries to be created and deleted in the pltCtlTable.
|
|
All value MUST be specified prior to a transition to active(1) state being accepted."
|
|
::= { pltCtlEntry 6 }
|
|
|
|
-- pingCtlTable
|
|
|
|
pingCtlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PingCtlEntry
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the ping Control Table for providing, via SNMP,
|
|
the capability of performing ping operations at
|
|
a remote host. The results of these operations are
|
|
stored in the pingResultsTable and the
|
|
pingProbeHistoryTable."
|
|
::= { pltMgmt 2 }
|
|
|
|
pingCtlEntry OBJECT-TYPE
|
|
SYNTAX PingCtlEntry
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines an entry in the pingCtlTable. The first index
|
|
element, pingCtlOwnerIndex, is of type SnmpAdminString,
|
|
a textual convention that allows for use of the SNMPv3
|
|
View-Based Access Control Model (RFC 2575 [11], VACM)
|
|
and allows an management application to identify its
|
|
entries. The second index, pingCtlTestName (also an
|
|
SnmpAdminString), enables the same management
|
|
application to have multiple outstanding requests."
|
|
INDEX {
|
|
pingCtlServInstType,
|
|
pingCtlServInstId,
|
|
pingCtlOwnerIndex,
|
|
pingCtlTestName
|
|
}
|
|
::= { pingCtlTable 1 }
|
|
|
|
PingCtlEntry ::=
|
|
SEQUENCE {
|
|
pingCtlServInstType INTEGER,
|
|
pingCtlServInstId INTEGER,
|
|
pingCtlOwnerIndex SnmpAdminString,
|
|
pingCtlTestName SnmpAdminString,
|
|
pingCtlTargetAddressType InetAddressType,
|
|
pingCtlTargetAddress InetAddress,
|
|
pingCtlDataSize Unsigned32,
|
|
pingCtlTimeOut Unsigned32,
|
|
pingCtlProbeCount Unsigned32,
|
|
pingCtlAdminStatus INTEGER,
|
|
pingCtlDataFill OCTET STRING,
|
|
pingCtlFrequency Unsigned32,
|
|
pingCtlMaxRows Unsigned32,
|
|
pingCtlStorageType StorageType,
|
|
pingCtlTrapGeneration BITS,
|
|
pingCtlTrapProbeFailureFilter Unsigned32,
|
|
pingCtlTrapTestFailureFilter Unsigned32,
|
|
pingCtlType OBJECT IDENTIFIER,
|
|
pingCtlDescr SnmpAdminString,
|
|
pingCtlSourceAddressType InetAddressType,
|
|
pingCtlSourceAddress InetAddress,
|
|
pingCtlIfIndex InterfaceIndexOrZero,
|
|
pingCtlByPassRouteTable TruthValue,
|
|
pingCtlDSField Unsigned32,
|
|
pingCtlRowStatus RowStatus
|
|
}
|
|
|
|
pingCtlServInstType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
vlan (1)
|
|
}
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of the service instance that this ping entry belong to.
|
|
1: VLAN.
|
|
This item would be used as an index
|
|
"
|
|
::= { pingCtlEntry 1 }
|
|
|
|
pingCtlServInstId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ID of the service instance that this ping entry belong to.
|
|
This item would be used as an index"
|
|
::= { pingCtlEntry 2 }
|
|
|
|
|
|
|
|
pingCtlOwnerIndex OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE(0..32))
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"To facilitate the provisioning of access control by a
|
|
security administrator using the View-Based Access
|
|
Control Model (RFC 2575, VACM) for tables in which
|
|
multiple users may need to independently create or
|
|
modify entries, the initial index is used as an 'owner
|
|
index'. Such an initial index has a syntax of
|
|
SnmpAdminString, and can thus be trivially mapped to a
|
|
securityName or groupName as defined in VACM, in
|
|
accordance with a security policy.
|
|
When used in conjunction with such a security policy all
|
|
entries in the table belonging to a particular user (or
|
|
group) will have the same value for this initial index.
|
|
For a given user's entries in a particular table, the
|
|
object identifiers for the information in these entries
|
|
will have the same subidentifiers (except for the 'column'
|
|
subidentifier) up to the end of the encoded owner index.
|
|
To configure VACM to permit access to this portion of the
|
|
table, one would create vacmViewTreeFamilyTable entries
|
|
with the value of vacmViewTreeFamilySubtree including
|
|
the owner index portion, and vacmViewTreeFamilyMask
|
|
'wildcarding' the column subidentifier. More elaborate
|
|
configurations are possible."
|
|
::= { pingCtlEntry 3 }
|
|
|
|
pingCtlTestName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE(0..32))
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the ping test. This is locally unique, within
|
|
the scope of an pingCtlOwnerIndex."
|
|
::= { pingCtlEntry 4 }
|
|
|
|
pingCtlTargetAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the type of host address to be used at a remote
|
|
host for performing a ping operation."
|
|
DEFVAL { unknown }
|
|
::= { pingCtlEntry 5 }
|
|
|
|
pingCtlTargetAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the host address to be used at a remote host for
|
|
performing a ping operation. The host address type is
|
|
determined by the object value of corresponding
|
|
pingCtlTargetAddressType.
|
|
A value for this object MUST be set prior to transitioning
|
|
its corresponding pingCtlEntry to active(1) via
|
|
pingCtlRowStatus."
|
|
DEFVAL { ''H }
|
|
::= { pingCtlEntry 6 }
|
|
|
|
pingCtlDataSize OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65507)
|
|
UNITS "octets"
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the size of the data portion to be
|
|
transmitted in a ping operation in octets. A ping
|
|
request is usually an ICMP message encoded
|
|
into an IP packet. An IP packet has a maximum size
|
|
of 65535 octets. Subtracting the size of the ICMP
|
|
or UDP header (both 8 octets) and the size of the IP
|
|
header (20 octets) yields a maximum size of 65507
|
|
octets."
|
|
DEFVAL { 0 }
|
|
::= { pingCtlEntry 7 }
|
|
|
|
pingCtlTimeOut OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..60)
|
|
UNITS "seconds"
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the time-out value, in seconds, for a
|
|
remote ping operation."
|
|
DEFVAL { 3 }
|
|
::= { pingCtlEntry 8 }
|
|
|
|
pingCtlProbeCount OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..15)
|
|
UNITS "probes"
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the number of times to perform a ping
|
|
operation at a remote host."
|
|
DEFVAL { 1 }
|
|
::= { pingCtlEntry 9 }
|
|
|
|
pingCtlAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1), -- test should be started
|
|
disabled(2) -- test should be stopped
|
|
}
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reflects the desired state that a pingCtlEntry should be
|
|
in:
|
|
enabled(1) - Attempt to activate the test as defined by
|
|
this pingCtlEntry.
|
|
disabled(2) - Deactivate the test as defined by this
|
|
pingCtlEntry.
|
|
Refer to the corresponding pingResultsOperStatus to
|
|
determine the operational state of the test defined by
|
|
this entry."
|
|
DEFVAL { disabled }
|
|
::= { pingCtlEntry 10 }
|
|
|
|
pingCtlDataFill OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..1024))
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The content of this object is used together with the
|
|
corresponding pingCtlDataSize value to determine how to
|
|
fill the data portion of a probe packet. The option of
|
|
selecting a data fill pattern can be useful when links
|
|
are compressed or have data pattern sensitivities. The
|
|
contents of pingCtlDataFill should be repeated in a ping
|
|
packet when the size of the data portion of the ping
|
|
packet is greater than the size of pingCtlDataFill."
|
|
DEFVAL { '00'H }
|
|
::= { pingCtlEntry 11 }
|
|
|
|
pingCtlFrequency OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "seconds"
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of seconds to wait before repeating a ping test
|
|
as defined by the value of the various objects in the
|
|
corresponding row.
|
|
A single ping test consists of a series of ping probes.
|
|
The number of probes is determined by the value of the
|
|
corresponding pingCtlProbeCount object. After a single
|
|
test completes the number of seconds as defined by the
|
|
value of pingCtlFrequency MUST elapse before the
|
|
next ping test is started.
|
|
A value of 0 for this object implies that the test
|
|
as defined by the corresponding entry will not be
|
|
repeated."
|
|
DEFVAL { 0 }
|
|
::= { pingCtlEntry 12 }
|
|
|
|
pingCtlMaxRows OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "rows"
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of entries allowed in the
|
|
pingProbeHistoryTable. An implementation of this
|
|
MIB will remove the oldest entry in the
|
|
pingProbeHistoryTable to allow the addition of an
|
|
new entry once the number of rows in the
|
|
pingProbeHistoryTable reaches this value.
|
|
Old entries are not removed when a new test is
|
|
started. Entries are added to the pingProbeHistoryTable
|
|
until pingCtlMaxRows is reached before entries begin to
|
|
be removed.
|
|
A value of 0 for this object disables creation of
|
|
pingProbeHistoryTable entries."
|
|
DEFVAL { 50 }
|
|
::= { pingCtlEntry 13 }
|
|
|
|
pingCtlStorageType OBJECT-TYPE
|
|
SYNTAX StorageType
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The storage type for this conceptual row.
|
|
Conceptual rows having the value 'permanent' need not
|
|
allow write-access to any columnar objects in the row."
|
|
DEFVAL { nonVolatile }
|
|
::= { pingCtlEntry 14 }
|
|
|
|
pingCtlTrapGeneration OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
probeFailure(0),
|
|
testFailure(1),
|
|
testCompletion(2)
|
|
}
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object determines when and if
|
|
to generate a notification for this entry:
|
|
probeFailure(0) - Generate a pingProbeFailed
|
|
notification subject to the value of
|
|
pingCtlTrapProbeFailureFilter. The object
|
|
pingCtlTrapProbeFailureFilter can be used
|
|
to specify the number of successive probe failures
|
|
that are required before a pingProbeFailed
|
|
notification can be generated.
|
|
testFailure(1) - Generate a pingTestFailed
|
|
notification. In this instance the object
|
|
pingCtlTrapTestFailureFilter can be used to
|
|
determine the number of probe failures that
|
|
signal when a test fails.
|
|
testCompletion(2) - Generate a pingTestCompleted
|
|
notification.
|
|
The value of this object defaults to zero, indicating
|
|
that none of the above options have been selected."
|
|
::= { pingCtlEntry 15 }
|
|
|
|
pingCtlTrapProbeFailureFilter OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..15)
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is used to determine when
|
|
to generate a pingProbeFailed NOTIFICATION.
|
|
|
|
Setting pingCtlTrapGeneration
|
|
to probeFailure(0) implies that a pingProbeFailed
|
|
NOTIFICATION is generated only when the number of
|
|
successive probe failures as indicated by the
|
|
value of pingCtlTrapPrbefailureFilter fail within
|
|
a given ping test."
|
|
DEFVAL { 1 }
|
|
::= { pingCtlEntry 16 }
|
|
|
|
pingCtlTrapTestFailureFilter OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..15)
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is used to determine when
|
|
to generate a pingTestFailed NOTIFICATION.
|
|
Setting pingCtlTrapGeneration to testFailure(1)
|
|
implies that a pingTestFailed NOTIFICATION is
|
|
generated only when the number of ping failures
|
|
within a test exceed the value of
|
|
pingCtlTrapTestFailureFilter."
|
|
DEFVAL { 1 }
|
|
::= { pingCtlEntry 17 }
|
|
|
|
pingCtlType OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is used to either report or
|
|
select the implementation method to be used for
|
|
calculating a ping response time. The value of this
|
|
object MAY be selected from pingImplementationTypeDomains.
|
|
Additional implementation types SHOULD be allocated as
|
|
required by implementers of the DISMAN-PING-MIB under
|
|
their enterprise specific registration point and not
|
|
beneath pingImplementationTypeDomains."
|
|
DEFVAL { pingIcmpEcho }
|
|
::= { pingCtlEntry 18 }
|
|
|
|
pingCtlDescr OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The purpose of this object is to provide a
|
|
descriptive name of the remote ping test."
|
|
DEFVAL { '00'H }
|
|
::= { pingCtlEntry 19 }
|
|
|
|
pingCtlSourceAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the type of the source address,
|
|
pingCtlSourceAddress, to be used at a remote host
|
|
when performing a ping operation."
|
|
DEFVAL { ipv4 }
|
|
::= { pingCtlEntry 20 }
|
|
|
|
pingCtlSourceAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use the specified IP address (which must be given
|
|
in numeric form, not as a hostname) as the source
|
|
address in outgoing probe packets. On hosts with
|
|
more than one IP address, this option can be used
|
|
to force the source address to be something other
|
|
than the primary IP address of the interface the
|
|
probe packet is sent on. If the IP address is not
|
|
one of this machine's interface addresses, an error
|
|
is returned and nothing is sent. A zero length
|
|
octet string value for this object disables source
|
|
address specification.
|
|
The address type (InetAddressType) that relates to
|
|
this object is specified by the corresponding value
|
|
of pingCtlSourceAddressType."
|
|
DEFVAL { ''H }
|
|
::= { pingCtlEntry 21 }
|
|
|
|
pingCtlIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to an interface's ifIndex prior
|
|
to starting a remote ping operation directs
|
|
the ping probes to be transmitted over the
|
|
specified interface. A value of zero for this object
|
|
means that this option is not enabled."
|
|
DEFVAL { 0 }
|
|
::= { pingCtlEntry 22 }
|
|
|
|
pingCtlByPassRouteTable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The purpose of this object is to optionally enable
|
|
bypassing the route table. If enabled, the remote
|
|
host will bypass the normal routing tables and send
|
|
directly to a host on an attached network. If the
|
|
host is not on a directly-attached network, an
|
|
error is returned. This option can be used to perform
|
|
the ping operation to a local host through an
|
|
interface that has no route defined (e.g., after the
|
|
interface was dropped by routed)."
|
|
DEFVAL { false }
|
|
::= { pingCtlEntry 23 }
|
|
|
|
pingCtlDSField OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the value to store in the Differentiated
|
|
Services (DS) Field in the IP packet used to
|
|
encapsulate the ping probe. The DS Field is defined
|
|
as the Type of Service (TOS) octet in a IPv4 header
|
|
or as the Traffic Class octet in a IPv6 header.
|
|
The value of this object must be a decimal integer
|
|
in the range from 0 to 255. This option can be used
|
|
to determine what effect an explicit DS Field setting
|
|
has on a ping response. Not all values are legal or
|
|
meaningful. A value of 0 means that the function
|
|
represented by this option is not supported. DS Field
|
|
usage is often not supported by IP implementations and
|
|
not all values are supported. Refer to RFC 2474 for
|
|
guidance on usage of this field."
|
|
REFERENCE
|
|
"Refer to RFC 2474 for the definition of the
|
|
Differentiated Services Field and to RFC 1812
|
|
Section 5.3.2 for Type of Service (TOS)."
|
|
DEFVAL { 0 }
|
|
::= { pingCtlEntry 24 }
|
|
|
|
pingCtlRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows entries to be created and deleted
|
|
in the pingCtlTable. Deletion of an entry in this
|
|
table results in all corresponding (same
|
|
pingCtlOwnerIndex and pingCtlTestName index values)
|
|
pingResultsTable and pingProbeHistoryTable entries
|
|
being deleted.
|
|
A value MUST be specified for pingCtlTargetAddress
|
|
prior to a transition to active(1) state being
|
|
accepted.
|
|
Activation of a remote ping operation is controlled
|
|
via pingCtlAdminStatus and not by changing
|
|
this object's value to active(1).
|
|
Transitions in and out of active(1) state are not
|
|
allowed while an entry's pingResultsOperStatus is
|
|
active(1) with the exception that deletion of
|
|
an entry in this table by setting its RowStatus
|
|
object to destroy(6) will stop an active
|
|
ping operation.
|
|
The operational state of a ping operation
|
|
can be determined by examination of its
|
|
pingResultsOperStatus object."
|
|
REFERENCE
|
|
"See definition of RowStatus in RFC 2579, 'Textual
|
|
Conventions for SMIv2.'"
|
|
::= { pingCtlEntry 25 }
|
|
|
|
-- Ping Results Table
|
|
|
|
pingResultsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PingResultsEntry
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the Ping Results Table for providing
|
|
the capability of performing ping operations at
|
|
a remote host. The results of these operations are
|
|
stored in the pingResultsTable and the pingPastProbeTable.
|
|
An entry is added to the pingResultsTable when an
|
|
pingCtlEntry is started by successful transition
|
|
of its pingCtlAdminStatus object to enabled(1).
|
|
An entry is removed from the pingResultsTable when
|
|
its corresponding pingCtlEntry is deleted."
|
|
::= { pltMgmt 3 }
|
|
|
|
pingResultsEntry OBJECT-TYPE
|
|
SYNTAX PingResultsEntry
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines an entry in the pingResultsTable. The
|
|
pingResultsTable has the same indexing as the
|
|
pingCtlTable in order for a pingResultsEntry to
|
|
correspond to the pingCtlEntry that caused it to
|
|
be created."
|
|
INDEX {
|
|
pingCtlServInstType,
|
|
pingCtlServInstId,
|
|
pingCtlOwnerIndex,
|
|
pingCtlTestName
|
|
}
|
|
::= { pingResultsTable 1 }
|
|
|
|
PingResultsEntry ::=
|
|
SEQUENCE {
|
|
pingResultsOperStatus INTEGER,
|
|
pingResultsIpTargetAddressType InetAddressType,
|
|
pingResultsIpTargetAddress InetAddress,
|
|
pingResultsMinRtt Unsigned32,
|
|
pingResultsMaxRtt Unsigned32,
|
|
pingResultsAverageRtt Unsigned32,
|
|
pingResultsProbeResponses Unsigned32,
|
|
pingResultsSentProbes Unsigned32,
|
|
pingResultsRttSumOfSquares Unsigned32,
|
|
pingResultsLastGoodProbe DateAndTime
|
|
}
|
|
|
|
pingResultsOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1), -- test is in progress
|
|
disabled(2) -- test has stopped
|
|
}
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reflects the operational state of a pingCtlEntry:
|
|
enabled(1) - Test is active.
|
|
disabled(2) - Test has stopped."
|
|
::= { pingResultsEntry 1 }
|
|
|
|
pingResultsIpTargetAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This objects indicates the type of address stored
|
|
in the corresponding pingResultsIpTargetAddress
|
|
object."
|
|
DEFVAL { unknown }
|
|
::= { pingResultsEntry 2 }
|
|
|
|
pingResultsIpTargetAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This objects reports the IP address associated
|
|
with a pingCtlTargetAddress value when the destination
|
|
address is specified as a DNS name. The value of
|
|
this object should be a zero length octet string
|
|
when a DNS name is not specified or when a
|
|
specified DNS name fails to resolve."
|
|
DEFVAL { ''H }
|
|
::= { pingResultsEntry 3 }
|
|
|
|
pingResultsMinRtt OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "milliseconds"
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum ping round-trip-time (RTT) received. A value
|
|
of 0 for this object implies that no RTT has been received."
|
|
::= { pingResultsEntry 4 }
|
|
|
|
pingResultsMaxRtt OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "milliseconds"
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum ping round-trip-time (RTT) received. A value
|
|
of 0 for this object implies that no RTT has been received."
|
|
::= { pingResultsEntry 5 }
|
|
|
|
pingResultsAverageRtt OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "milliseconds"
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current average ping round-trip-time (RTT)."
|
|
::= { pingResultsEntry 6 }
|
|
|
|
pingResultsProbeResponses OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "responses"
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of responses received for the corresponding
|
|
pingCtlEntry and pingResultsEntry. The value of this object
|
|
MUST be reported as 0 when no probe responses have been
|
|
received."
|
|
::= { pingResultsEntry 7 }
|
|
|
|
pingResultsSentProbes OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "probes"
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object reflects the number of probes sent
|
|
for the corresponding pingCtlEntry and pingResultsEntry.
|
|
The value of this object MUST be reported as 0 when no probes
|
|
have been sent."
|
|
::= { pingResultsEntry 8 }
|
|
|
|
pingResultsRttSumOfSquares OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "milliseconds"
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the sum of the squares for all ping
|
|
responses received. Its purpose is to enable standard
|
|
deviation calculation. The value of this object MUST
|
|
be reported as 0 when no ping responses have been
|
|
received."
|
|
::= { pingResultsEntry 9 }
|
|
|
|
pingResultsLastGoodProbe OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Date and time when the last response was received for
|
|
a probe."
|
|
::= { pingResultsEntry 10 }
|
|
|
|
-- Ping Probe History Table
|
|
|
|
pingProbeHistoryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PingProbeHistoryEntry
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines a table for storing the results of a ping
|
|
operation. Entries in this table are limited by
|
|
the value of the corresponding pingCtlMaxRows
|
|
object.
|
|
An entry in this table is created when the result of
|
|
a ping probe is determined. The initial 2 instance
|
|
identifier index values identify the pingCtlEntry
|
|
that a probe result (pingProbeHistoryEntry) belongs
|
|
to. An entry is removed from this table when
|
|
its corresponding pingCtlEntry is deleted.
|
|
An implementation of this MIB will remove the oldest
|
|
entry in the pingProbeHistoryTable to allow the
|
|
addition of an new entry once the number of rows in
|
|
the pingProbeHistoryTable reaches the value specified
|
|
by pingCtlMaxRows."
|
|
::= { pltMgmt 4 }
|
|
|
|
pingProbeHistoryEntry OBJECT-TYPE
|
|
SYNTAX PingProbeHistoryEntry
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines an entry in the pingProbeHistoryTable.
|
|
The first two index elements identify the
|
|
pingCtlEntry that a pingProbeHistoryEntry belongs
|
|
to. The third index element selects a single
|
|
probe result."
|
|
INDEX {
|
|
pingCtlServInstType,
|
|
pingCtlServInstId,
|
|
pingCtlOwnerIndex,
|
|
pingCtlTestName,
|
|
pingProbeHistoryIndex
|
|
}
|
|
::= { pingProbeHistoryTable 1 }
|
|
|
|
PingProbeHistoryEntry ::=
|
|
SEQUENCE {
|
|
pingProbeHistoryIndex Unsigned32,
|
|
pingProbeHistoryResponse Unsigned32,
|
|
pingProbeHistoryStatus OperationResponseStatus,
|
|
pingProbeHistoryLastRC Integer32,
|
|
pingProbeHistoryTime DateAndTime
|
|
}
|
|
|
|
pingProbeHistoryIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..'ffffffff'h)
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in this table is created when the result of
|
|
a ping probe is determined. The initial 2 instance
|
|
identifier index values identify the pingCtlEntry
|
|
that a probe result (pingProbeHistoryEntry) belongs
|
|
to.
|
|
An implementation MUST start assigning
|
|
pingProbeHistoryIndex values at 1 and wrap after
|
|
exceeding the maximum possible value as defined by
|
|
the limit of this object ('ffffffff'h)."
|
|
::= { pingProbeHistoryEntry 1 }
|
|
|
|
pingProbeHistoryResponse OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "milliseconds"
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time measured in milliseconds from when
|
|
a probe was sent to when its response was received or
|
|
when it timed out. The value of this object is reported
|
|
as 0 when it is not possible to transmit a probe."
|
|
::= { pingProbeHistoryEntry 2 }
|
|
|
|
pingProbeHistoryStatus OBJECT-TYPE
|
|
SYNTAX OperationResponseStatus
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of a particular probe done by a remote host."
|
|
::= { pingProbeHistoryEntry 3 }
|
|
|
|
pingProbeHistoryLastRC OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last implementation method specific reply code received.
|
|
If the ICMP Echo capability is being used then a successful
|
|
probe ends when an ICMP response is received that contains
|
|
the code ICMP-ECHOREPLY(0). The ICMP responses are defined
|
|
normally in the ip-icmp include file."
|
|
::= { pingProbeHistoryEntry 4 }
|
|
|
|
pingProbeHistoryTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Timestamp for when this probe result was determined."
|
|
::= { pingProbeHistoryEntry 5 }
|
|
|
|
-- Traceroute Control Table
|
|
|
|
traceRouteCtlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TraceRouteCtlEntry
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the Remote Operations Traceroute Control Table for
|
|
providing the capability of invoking traceroute from a remote
|
|
host. The results of traceroute operations can be stored in
|
|
the traceRouteResultsTable, traceRouteProbeHistoryTable, and
|
|
the traceRouteHopsTable."
|
|
::= { pltMgmt 5 }
|
|
|
|
traceRouteCtlEntry OBJECT-TYPE
|
|
SYNTAX TraceRouteCtlEntry
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines an entry in the traceRouteCtlTable. The first
|
|
index element, traceRouteCtlOwnerIndex, is of type
|
|
SnmpAdminString, a textual convention that allows for
|
|
use of the SNMPv3 View-Based Access Control Model
|
|
(RFC 2575 [11], VACM) and allows an management
|
|
application to identify its entries. The second index,
|
|
traceRouteCtlTestName (also an SnmpAdminString),
|
|
enables the same management application to have
|
|
multiple requests outstanding."
|
|
INDEX {
|
|
traceRouteCtlServInstType,
|
|
traceRouteCtlServInstId,
|
|
traceRouteCtlOwnerIndex,
|
|
traceRouteCtlTestName
|
|
}
|
|
::= { traceRouteCtlTable 1 }
|
|
|
|
TraceRouteCtlEntry ::=
|
|
SEQUENCE {
|
|
traceRouteCtlServInstType INTEGER,
|
|
traceRouteCtlServInstId INTEGER,
|
|
traceRouteCtlOwnerIndex SnmpAdminString,
|
|
traceRouteCtlTestName SnmpAdminString,
|
|
traceRouteCtlTargetAddressType InetAddressType,
|
|
traceRouteCtlTargetAddress InetAddress,
|
|
traceRouteCtlByPassRouteTable TruthValue,
|
|
traceRouteCtlDataSize Unsigned32,
|
|
traceRouteCtlTimeOut Unsigned32,
|
|
traceRouteCtlProbesPerHop Unsigned32,
|
|
traceRouteCtlPort Unsigned32,
|
|
traceRouteCtlMaxTtl Unsigned32,
|
|
traceRouteCtlDSField Unsigned32,
|
|
traceRouteCtlSourceAddressType InetAddressType,
|
|
traceRouteCtlSourceAddress InetAddress,
|
|
traceRouteCtlIfIndex InterfaceIndexOrZero,
|
|
traceRouteCtlMiscOptions SnmpAdminString,
|
|
traceRouteCtlMaxFailures Unsigned32,
|
|
traceRouteCtlDontFragment TruthValue,
|
|
traceRouteCtlInitialTtl Unsigned32,
|
|
traceRouteCtlFrequency Unsigned32,
|
|
traceRouteCtlStorageType StorageType,
|
|
traceRouteCtlAdminStatus INTEGER,
|
|
traceRouteCtlMaxRows Unsigned32,
|
|
traceRouteCtlTrapGeneration BITS,
|
|
traceRouteCtlDescr SnmpAdminString,
|
|
traceRouteCtlCreateHopsEntries TruthValue,
|
|
traceRouteCtlType OBJECT IDENTIFIER,
|
|
traceRouteCtlRowStatus RowStatus
|
|
}
|
|
|
|
traceRouteCtlServInstType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
vlan (1)
|
|
}
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of the service instance that this traceRoute entry belong to.
|
|
1: VLAN.
|
|
This item would be used as an index
|
|
"
|
|
::= { traceRouteCtlEntry 1 }
|
|
|
|
traceRouteCtlServInstId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ID of the service instance that this traceRoute entry belong to.
|
|
This item would be used as an index"
|
|
::= { traceRouteCtlEntry 2 }
|
|
|
|
traceRouteCtlOwnerIndex OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE(0..32))
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"To facilitate the provisioning of access control by a
|
|
security administrator using the View-Based Access
|
|
Control Model (RFC 2575, VACM) for tables in which
|
|
multiple users may need to independently create or
|
|
modify entries, the initial index is used as an 'owner
|
|
index'. Such an initial index has a syntax of
|
|
SnmpAdminString, and can thus be trivially mapped to a
|
|
securityName or groupName as defined in VACM, in
|
|
accordance with a security policy.
|
|
When used in conjunction with such a security policy
|
|
all entries in the table belonging to a particular user
|
|
(or group) will have the same value for this initial
|
|
index. For a given user's entries in a particular
|
|
table, the object identifiers for the information in
|
|
these entries will have the same subidentifiers (except
|
|
for the 'column' subidentifier) up to the end of the
|
|
encoded owner index. To configure VACM to permit access
|
|
to this portion of the table, one would create
|
|
vacmViewTreeFamilyTable entries with the value of
|
|
vacmViewTreeFamilySubtree including the owner index
|
|
portion, and vacmViewTreeFamilyMask 'wildcarding' the
|
|
column subidentifier. More elaborate configurations
|
|
are possible."
|
|
::= { traceRouteCtlEntry 3 }
|
|
|
|
traceRouteCtlTestName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE(0..32))
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of a traceroute test. This is locally unique,
|
|
within the scope of an traceRouteCtlOwnerIndex."
|
|
::= { traceRouteCtlEntry 4 }
|
|
|
|
traceRouteCtlTargetAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the type of host address to be used on the
|
|
traceroute request at the remote host."
|
|
DEFVAL { ipv4 }
|
|
::= { traceRouteCtlEntry 5 }
|
|
|
|
traceRouteCtlTargetAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the host address used on the
|
|
traceroute request at the remote host. The
|
|
host address type can be determined by the
|
|
examining the value of the corresponding
|
|
traceRouteCtlTargetAddressType index element.
|
|
A value for this object MUST be set prior to
|
|
transitioning its corresponding traceRouteCtlEntry to
|
|
active(1) via traceRouteCtlRowStatus."
|
|
::= { traceRouteCtlEntry 6 }
|
|
|
|
traceRouteCtlByPassRouteTable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The purpose of this object is to optionally enable
|
|
bypassing the route table. If enabled, the remote
|
|
host will bypass the normal routing tables and send
|
|
directly to a host on an attached network. If the
|
|
host is not on a directly-attached network, an
|
|
error is returned. This option can be used to perform
|
|
the traceroute operation to a local host through an
|
|
interface that has no route defined (e.g., after the
|
|
interface was dropped by routed)."
|
|
DEFVAL { false }
|
|
::= { traceRouteCtlEntry 7 }
|
|
|
|
traceRouteCtlDataSize OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65507)
|
|
UNITS "octets"
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the size of the data portion of a traceroute
|
|
request in octets. A traceroute request is essentially
|
|
transmitted by encoding a UDP datagram into a
|
|
IP packet. So subtracting the size of a UDP header
|
|
(8 octets) and the size of a IP header (20 octets)
|
|
yields a maximum of 65507 octets."
|
|
DEFVAL { 0 }
|
|
::= { traceRouteCtlEntry 8 }
|
|
|
|
traceRouteCtlTimeOut OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..60)
|
|
UNITS "seconds"
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the time-out value, in seconds, for
|
|
a traceroute request."
|
|
DEFVAL { 3 }
|
|
::= { traceRouteCtlEntry 9 }
|
|
|
|
traceRouteCtlProbesPerHop OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..10)
|
|
UNITS "probes"
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the number of times to reissue a traceroute
|
|
request with the same time-to-live (TTL) value."
|
|
DEFVAL { 3 }
|
|
::= { traceRouteCtlEntry 10 }
|
|
|
|
traceRouteCtlPort OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..65535)
|
|
UNITS "UDP Port"
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the UDP port to send the traceroute
|
|
request to. Need to specify a port that is not in
|
|
use at the destination (target) host. The default
|
|
value for this object is the IANA assigned port,
|
|
33434, for the traceroute function."
|
|
DEFVAL { 33434 }
|
|
::= { traceRouteCtlEntry 11 }
|
|
|
|
traceRouteCtlMaxTtl OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..255)
|
|
UNITS "time-to-live value"
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the maximum time-to-live value."
|
|
DEFVAL { 30 }
|
|
::= { traceRouteCtlEntry 12 }
|
|
|
|
traceRouteCtlDSField OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the value to store in the Differentiated
|
|
Services (DS) Field in the IP packet used to
|
|
encapsulate the traceroute probe. The DS Field is
|
|
defined as the Type of Service (TOS) octet in a IPv4
|
|
header or as the Traffic Class octet in a IPv6 header.
|
|
|
|
The value of this object must be a decimal integer
|
|
in the range from 0 to 255. This option can be used
|
|
to determine what effect an explicit DS Field setting
|
|
has on a traceroute response. Not all values are legal
|
|
or meaningful. DS Field usage is often not supported
|
|
by IP implementations. A value of 0 means that the
|
|
function represented by this option is not supported.
|
|
Useful TOS octet values are probably '16' (low delay)
|
|
and '8' ( high throughput)."
|
|
REFERENCE
|
|
"Refer to RFC 2474 for the definition of the
|
|
Differentiated Services Field and to RFC 1812
|
|
Section 5.3.2 for Type of Service (TOS)."
|
|
DEFVAL { 0 }
|
|
::= { traceRouteCtlEntry 13 }
|
|
|
|
traceRouteCtlSourceAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the type of the source address,
|
|
traceRouteCtlSourceAddress, to be used at a remote host
|
|
when performing a traceroute operation."
|
|
DEFVAL { unknown }
|
|
::= { traceRouteCtlEntry 14 }
|
|
|
|
traceRouteCtlSourceAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use the specified IP address (which must be given
|
|
as an IP number, not a hostname) as the source
|
|
address in outgoing probe packets. On hosts with
|
|
more than one IP address, this option can be used
|
|
to force the source address to be something other
|
|
than the primary IP address of the interface the
|
|
probe packet is sent on. If the IP address is not
|
|
one of this machine's interface addresses, an error
|
|
is returned and nothing is sent. A zero length
|
|
octet string value for this object disables source
|
|
address specification.
|
|
The address type (InetAddressType) that relates to
|
|
this object is specified by the corresponding value
|
|
of traceRouteCtlSourceAddressType."
|
|
DEFVAL { ''H }
|
|
::= { traceRouteCtlEntry 15 }
|
|
|
|
traceRouteCtlIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to an interface's ifIndex prior
|
|
to starting a remote traceroute operation directs
|
|
the traceroute probes to be transmitted over the
|
|
specified interface. A value of zero for this object
|
|
implies that this option is not enabled."
|
|
DEFVAL { 0 }
|
|
::= { traceRouteCtlEntry 16 }
|
|
|
|
traceRouteCtlMiscOptions OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables an application to specify implementation
|
|
dependent options."
|
|
DEFVAL { ''H }
|
|
::= { traceRouteCtlEntry 17 }
|
|
|
|
traceRouteCtlMaxFailures OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
UNITS "timeouts"
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object indicates the maximum number
|
|
of consecutive timeouts allowed before terminating
|
|
a remote traceroute request. A value of either 255 (maximum
|
|
hop count/possible TTL value) or a 0 indicates that the
|
|
function of terminating a remote traceroute request when a
|
|
specific number of successive timeouts are detected is
|
|
disabled."
|
|
DEFVAL { 5 }
|
|
::= { traceRouteCtlEntry 18 }
|
|
|
|
traceRouteCtlDontFragment OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables setting of the don't fragment flag (DF)
|
|
in the IP header for a probe. Use of this object enables
|
|
performing a manual PATH MTU test."
|
|
DEFVAL { false }
|
|
::= { traceRouteCtlEntry 19 }
|
|
|
|
traceRouteCtlInitialTtl OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object specifies the initial TTL value to
|
|
use. This enables bypassing the initial (often well known)
|
|
portion of a path."
|
|
DEFVAL { 1 }
|
|
::= { traceRouteCtlEntry 20 }
|
|
|
|
traceRouteCtlFrequency OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "seconds"
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of seconds to wait before repeating a
|
|
traceroute test as defined by the value of the
|
|
various objects in the corresponding row.
|
|
The number of hops in a single traceroute test
|
|
is determined by the value of the corresponding
|
|
traceRouteCtlProbesPerHop object. After a
|
|
single test completes the number of seconds as defined
|
|
by the value of traceRouteCtlFrequency MUST elapse
|
|
before the next traceroute test is started.
|
|
A value of 0 for this object implies that the test
|
|
as defined by the corresponding entry will not be
|
|
repeated."
|
|
DEFVAL { 0 }
|
|
::= { traceRouteCtlEntry 21 }
|
|
|
|
traceRouteCtlStorageType OBJECT-TYPE
|
|
SYNTAX StorageType
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The storage type for this conceptual row.
|
|
Conceptual rows having the value 'permanent' need not
|
|
allow write-access to any columnar objects in the row."
|
|
DEFVAL { nonVolatile }
|
|
::= { traceRouteCtlEntry 22 }
|
|
|
|
traceRouteCtlAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1), -- operation should be started
|
|
disabled(2) -- operation should be stopped
|
|
}
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reflects the desired state that an traceRouteCtlEntry
|
|
should be in:
|
|
enabled(1) - Attempt to activate the test as defined by
|
|
this traceRouteCtlEntry.
|
|
disabled(2) - Deactivate the test as defined by this
|
|
traceRouteCtlEntry.
|
|
Refer to the corresponding traceRouteResultsOperStatus to
|
|
determine the operational state of the test defined by
|
|
this entry."
|
|
DEFVAL { disabled }
|
|
::= { traceRouteCtlEntry 23 }
|
|
|
|
traceRouteCtlDescr OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The purpose of this object is to provide a
|
|
descriptive name of the remote traceroute
|
|
test."
|
|
DEFVAL { '00'H }
|
|
::= { traceRouteCtlEntry 24 }
|
|
|
|
traceRouteCtlMaxRows OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "rows"
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of entries allowed in the
|
|
traceRouteProbeHistoryTable. An implementation of
|
|
this MIB will remove the oldest entry in the
|
|
traceRouteProbeHistoryTable to allow the addition
|
|
of an new entry once the number of rows in the
|
|
traceRouteProbeHistoryTable reaches this value.
|
|
Old entries are not removed when a new test is
|
|
started. Entries are added to the
|
|
traceRouteProbeHistoryTable until traceRouteCtlMaxRows
|
|
is reached before entries begin to be removed.
|
|
A value of 0 for this object disables creation of
|
|
traceRouteProbeHistoryTable entries."
|
|
DEFVAL { 50 }
|
|
::= { traceRouteCtlEntry 25 }
|
|
|
|
traceRouteCtlTrapGeneration OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
pathChange(0),
|
|
testFailure(1),
|
|
testCompletion(2)
|
|
}
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object determines when and if to
|
|
to generate a notification for this entry:
|
|
pathChange(0) - Generate a traceRoutePathChange
|
|
notification when the current path varies from a
|
|
previously determined path.
|
|
testFailure(1) - Generate a traceRouteTestFailed
|
|
notification when the full path to a target
|
|
can't be determined.
|
|
testCompletion(2) - Generate a traceRouteTestCompleted
|
|
notification when the path to a target has been
|
|
determined.
|
|
The value of this object defaults to zero, indicating
|
|
that none of the above options have been selected."
|
|
::= { traceRouteCtlEntry 26 }
|
|
|
|
traceRouteCtlCreateHopsEntries OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current path for a traceroute test is kept in the
|
|
traceRouteHopsTable on a per hop basis when the value of
|
|
this object is true(1)."
|
|
DEFVAL { false }
|
|
::= { traceRouteCtlEntry 27 }
|
|
|
|
traceRouteCtlType OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is used either to report or
|
|
select the implementation method to be used for
|
|
performing a traceroute operation. The value of this
|
|
object may be selected from
|
|
traceRouteImplementationTypeDomains.
|
|
Additional implementation types should be allocated as
|
|
required by implementers of the DISMAN-TRACEROUTE-MIB
|
|
under their enterprise specific registration point and
|
|
not beneath traceRouteImplementationTypeDomains."
|
|
DEFVAL { traceRouteUsingUdpProbes }
|
|
::= { traceRouteCtlEntry 28 }
|
|
|
|
traceRouteCtlRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows entries to be created and deleted
|
|
in the traceRouteCtlTable. Deletion of an entry in
|
|
this table results in all corresponding (same
|
|
traceRouteCtlOwnerIndex and traceRouteCtlTestName
|
|
index values) traceRouteResultsTable,
|
|
traceRouteProbeHistoryTable, and traceRouteHopsTable
|
|
entries being deleted.
|
|
A value MUST be specified for traceRouteCtlTargetAddress
|
|
prior to a transition to active(1) state being
|
|
accepted.
|
|
Activation of a remote traceroute operation is
|
|
controlled via traceRouteCtlAdminStatus and not
|
|
by transitioning of this object's value to active(1).
|
|
Transitions in and out of active(1) state are not
|
|
allowed while an entry's traceRouteResultsOperStatus
|
|
is active(1) with the exception that deletion of
|
|
an entry in this table by setting its RowStatus
|
|
object to destroy(6) will stop an active
|
|
traceroute operation.
|
|
The operational state of an traceroute operation
|
|
can be determined by examination of the corresponding
|
|
traceRouteResultsOperStatus object."
|
|
REFERENCE
|
|
"See definition of RowStatus in RFC 2579, 'Textual
|
|
Conventions for SMIv2.'"
|
|
::= { traceRouteCtlEntry 29 }
|
|
|
|
|
|
-- Traceroute Results Table
|
|
|
|
traceRouteResultsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TraceRouteResultsEntry
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the Remote Operations Traceroute Results Table for
|
|
keeping track of the status of a traceRouteCtlEntry.
|
|
|
|
An entry is added to the traceRouteResultsTable when an
|
|
traceRouteCtlEntry is started by successful transition
|
|
of its traceRouteCtlAdminStatus object to enabled(1).
|
|
An entry is removed from the traceRouteResultsTable when
|
|
its corresponding traceRouteCtlEntry is deleted."
|
|
::= { pltMgmt 6 }
|
|
|
|
traceRouteResultsEntry OBJECT-TYPE
|
|
SYNTAX TraceRouteResultsEntry
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines an entry in the traceRouteResultsTable. The
|
|
traceRouteResultsTable has the same indexing as the
|
|
traceRouteCtlTable in order for a traceRouteResultsEntry
|
|
to correspond to the traceRouteCtlEntry that caused it to
|
|
be created."
|
|
INDEX {
|
|
traceRouteCtlServInstType,
|
|
traceRouteCtlServInstId,
|
|
traceRouteCtlOwnerIndex,
|
|
traceRouteCtlTestName
|
|
}
|
|
::= { traceRouteResultsTable 1 }
|
|
|
|
TraceRouteResultsEntry ::=
|
|
SEQUENCE {
|
|
traceRouteResultsOperStatus INTEGER,
|
|
traceRouteResultsCurHopCount Gauge32,
|
|
traceRouteResultsCurProbeCount Gauge32,
|
|
traceRouteResultsIpTgtAddrType InetAddressType,
|
|
traceRouteResultsIpTgtAddr InetAddress,
|
|
traceRouteResultsTestAttempts Unsigned32,
|
|
traceRouteResultsTestSuccesses Unsigned32,
|
|
traceRouteResultsLastGoodPath DateAndTime
|
|
}
|
|
|
|
traceRouteResultsOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1), -- test is in progress
|
|
disabled(2) -- test has stopped
|
|
}
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reflects the operational state of an traceRouteCtlEntry:
|
|
enabled(1) - Test is active.
|
|
disabled(2) - Test has stopped."
|
|
::= { traceRouteResultsEntry 1 }
|
|
|
|
traceRouteResultsCurHopCount OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "hops"
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reflects the current TTL value (range from 1 to
|
|
255) for a remote traceroute operation.
|
|
Maximum TTL value is determined by
|
|
traceRouteCtlMaxTtl."
|
|
::= { traceRouteResultsEntry 2 }
|
|
|
|
traceRouteResultsCurProbeCount OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "probes"
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reflects the current probe count (1..10) for
|
|
a remote traceroute operation. The maximum
|
|
probe count is determined by
|
|
traceRouteCtlProbesPerHop."
|
|
::= { traceRouteResultsEntry 3 }
|
|
|
|
traceRouteResultsIpTgtAddrType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This objects indicates the type of address stored
|
|
in the corresponding traceRouteResultsIpTgtAddr
|
|
object."
|
|
::= { traceRouteResultsEntry 4 }
|
|
|
|
traceRouteResultsIpTgtAddr OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This objects reports the IP address associated
|
|
with a traceRouteCtlTargetAddress value when the
|
|
destination address is specified as a DNS name.
|
|
The value of this object should be a zero length
|
|
octet string when a DNS name is not specified or
|
|
when a specified DNS name fails to resolve."
|
|
::= { traceRouteResultsEntry 5 }
|
|
|
|
traceRouteResultsTestAttempts OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "tests"
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current number of attempts to determine a path
|
|
to a target. The value of this object MUST be started
|
|
at 0."
|
|
::= { traceRouteResultsEntry 6 }
|
|
|
|
traceRouteResultsTestSuccesses OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "tests"
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current number of attempts to determine a path
|
|
to a target that have succeeded. The value of this
|
|
object MUST be reported as 0 when no attempts have
|
|
succeeded."
|
|
::= { traceRouteResultsEntry 7 }
|
|
|
|
traceRouteResultsLastGoodPath OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The date and time when the last complete path
|
|
was determined."
|
|
::= { traceRouteResultsEntry 8 }
|
|
|
|
-- Trace Route Probe History Table
|
|
|
|
traceRouteProbeHistoryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TraceRouteProbeHistoryEntry
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the Remote Operations Traceroute Results Table for
|
|
storing the results of a traceroute operation.
|
|
An implementation of this MIB will remove the oldest
|
|
entry in the traceRouteProbeHistoryTable to allow the
|
|
addition of an new entry once the number of rows in
|
|
the traceRouteProbeHistoryTable reaches the value specified
|
|
by traceRouteCtlMaxRows."
|
|
::= { pltMgmt 7 }
|
|
|
|
traceRouteProbeHistoryEntry OBJECT-TYPE
|
|
SYNTAX TraceRouteProbeHistoryEntry
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines a table for storing the results of a traceroute
|
|
operation. Entries in this table are limited by
|
|
the value of the corresponding traceRouteCtlMaxRows
|
|
object.
|
|
The first two index elements identify the
|
|
traceRouteCtlEntry that a traceRouteProbeHistoryEntry
|
|
belongs to. The third index element selects a single
|
|
traceroute operation result. The fourth and fifth indexes
|
|
select the hop and the probe for a particular
|
|
traceroute operation."
|
|
INDEX {
|
|
traceRouteCtlServInstType,
|
|
traceRouteCtlServInstId,
|
|
traceRouteCtlOwnerIndex,
|
|
traceRouteCtlTestName,
|
|
traceRouteProbeHistoryIndex,
|
|
traceRouteProbeHistoryHopIndex,
|
|
traceRouteProbeHistoryProbeIndex
|
|
}
|
|
::= { traceRouteProbeHistoryTable 1 }
|
|
|
|
TraceRouteProbeHistoryEntry ::=
|
|
SEQUENCE {
|
|
traceRouteProbeHistoryIndex Unsigned32,
|
|
traceRouteProbeHistoryHopIndex Unsigned32,
|
|
traceRouteProbeHistoryProbeIndex Unsigned32,
|
|
traceRouteProbeHistoryHAddrType InetAddressType,
|
|
traceRouteProbeHistoryHAddr InetAddress,
|
|
traceRouteProbeHistoryResponse Unsigned32,
|
|
traceRouteProbeHistoryStatus OperationResponseStatus,
|
|
traceRouteProbeHistoryLastRC Integer32,
|
|
traceRouteProbeHistoryTime DateAndTime
|
|
}
|
|
|
|
traceRouteProbeHistoryIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..'ffffffff'h)
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in this table is created when the result of
|
|
a traceroute probe is determined. The initial 2 instance
|
|
identifier index values identify the traceRouteCtlEntry
|
|
that a probe result (traceRouteProbeHistoryEntry) belongs
|
|
to. An entry is removed from this table when
|
|
its corresponding traceRouteCtlEntry is deleted.
|
|
An implementation MUST start assigning
|
|
traceRouteProbeHistoryIndex values at 1 and wrap after
|
|
exceeding the maximum possible value as defined by the
|
|
limit of this object ('ffffffff'h)."
|
|
::= { traceRouteProbeHistoryEntry 1 }
|
|
|
|
traceRouteProbeHistoryHopIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..255)
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates which hop in a traceroute path that the probe's
|
|
results are for. The value of this object is initially
|
|
determined by the value of traceRouteCtlInitialTtl."
|
|
::= { traceRouteProbeHistoryEntry 2 }
|
|
|
|
traceRouteProbeHistoryProbeIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..10)
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the index of a probe for a particular
|
|
hop in a traceroute path. The number of probes per
|
|
hop is determined by the value of the corresponding
|
|
traceRouteCtlProbesPerHop object."
|
|
::= { traceRouteProbeHistoryEntry 3 }
|
|
|
|
traceRouteProbeHistoryHAddrType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This objects indicates the type of address stored
|
|
in the corresponding traceRouteProbeHistoryHAddr
|
|
object."
|
|
::= { traceRouteProbeHistoryEntry 4 }
|
|
|
|
traceRouteProbeHistoryHAddr OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The address of a hop in a traceroute path. This object
|
|
is not allowed to be a DNS name. The value of the
|
|
corresponding object, traceRouteProbeHistoryHAddrType,
|
|
indicates this object's IP address type."
|
|
::= { traceRouteProbeHistoryEntry 5 }
|
|
|
|
traceRouteProbeHistoryResponse OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "milliseconds"
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time measured in milliseconds from when
|
|
a probe was sent to when its response was received or
|
|
when it timed out. The value of this object is reported
|
|
as 0 when it is not possible to transmit a probe."
|
|
::= { traceRouteProbeHistoryEntry 6 }
|
|
|
|
traceRouteProbeHistoryStatus OBJECT-TYPE
|
|
SYNTAX OperationResponseStatus
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of a traceroute operation made by a remote
|
|
host for a particular probe."
|
|
::= { traceRouteProbeHistoryEntry 7 }
|
|
|
|
traceRouteProbeHistoryLastRC OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last implementation method specific reply code received.
|
|
Traceroute is usually implemented by transmitting a series of
|
|
probe packets with increasing time-to-live values. A probe
|
|
packet is a UDP datagram encapsulated into an IP packet.
|
|
Each hop in a path to the target (destination) host rejects
|
|
the probe packets (probe's TTL too small, ICMP reply) until
|
|
either the maximum TTL is exceeded or the target host is
|
|
received."
|
|
::= { traceRouteProbeHistoryEntry 8 }
|
|
|
|
traceRouteProbeHistoryTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Timestamp for when this probe results were determined."
|
|
::= { traceRouteProbeHistoryEntry 9 }
|
|
|
|
-- Traceroute Hop Results Table
|
|
|
|
traceRouteHopsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TraceRouteHopsEntry
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the Remote Operations Traceroute Hop Table for
|
|
keeping track of the results of traceroute tests on a
|
|
per hop basis."
|
|
::= { pltMgmt 8 }
|
|
|
|
traceRouteHopsEntry OBJECT-TYPE
|
|
SYNTAX TraceRouteHopsEntry
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines an entry in the traceRouteHopsTable.
|
|
The first two index elements identify the
|
|
traceRouteCtlEntry that a traceRouteHopsEntry
|
|
belongs to. The third index element,
|
|
traceRouteHopsHopIndex, selects a
|
|
hop in a traceroute path."
|
|
INDEX {
|
|
traceRouteCtlServInstType,
|
|
traceRouteCtlServInstId,
|
|
traceRouteCtlOwnerIndex,
|
|
traceRouteCtlTestName,
|
|
traceRouteHopsHopIndex
|
|
}
|
|
::= { traceRouteHopsTable 1 }
|
|
|
|
TraceRouteHopsEntry ::=
|
|
SEQUENCE {
|
|
traceRouteHopsHopIndex Unsigned32,
|
|
traceRouteHopsIpTgtAddressType InetAddressType,
|
|
traceRouteHopsIpTgtAddress InetAddress,
|
|
traceRouteHopsMinRtt Unsigned32,
|
|
traceRouteHopsMaxRtt Unsigned32,
|
|
traceRouteHopsAverageRtt Unsigned32,
|
|
traceRouteHopsRttSumOfSquares Unsigned32,
|
|
traceRouteHopsSentProbes Unsigned32,
|
|
traceRouteHopsProbeResponses Unsigned32,
|
|
traceRouteHopsLastGoodProbe DateAndTime
|
|
}
|
|
|
|
traceRouteHopsHopIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the hop index for a traceroute hop. Values
|
|
for this object with respect to the same
|
|
traceRouteCtlOwnerIndex and traceRouteCtlTestName
|
|
MUST start at 1 and increase monotonically.
|
|
The traceRouteHopsTable keeps the current traceroute
|
|
path per traceRouteCtlEntry if enabled by
|
|
setting the corresponding traceRouteCtlCreateHopsEntries
|
|
to true(1).
|
|
All hops (traceRouteHopsTable entries) in a traceroute
|
|
path MUST be updated at the same time when a traceroute
|
|
operation completes. Care needs to be applied when either
|
|
a path changes or can't be determined. The initial portion
|
|
of the path, up to the first hop change, MUST retain the
|
|
same traceRouteHopsHopIndex values. The remaining portion
|
|
of the path SHOULD be assigned new traceRouteHopsHopIndex
|
|
values."
|
|
::= { traceRouteHopsEntry 1 }
|
|
|
|
traceRouteHopsIpTgtAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This objects indicates the type of address stored
|
|
in the corresponding traceRouteHopsIpTargetAddress
|
|
object."
|
|
::= { traceRouteHopsEntry 2 }
|
|
|
|
traceRouteHopsIpTgtAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object reports the IP address associated with
|
|
the hop. A value for this object should be reported
|
|
as a numeric IP address and not as a DNS name."
|
|
::= { traceRouteHopsEntry 3 }
|
|
|
|
traceRouteHopsMinRtt OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum traceroute round-trip-time (RTT) received for
|
|
this hop. A value of 0 for this object implies that no
|
|
RTT has been received."
|
|
::= { traceRouteHopsEntry 4 }
|
|
|
|
traceRouteHopsMaxRtt OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum traceroute round-trip-time (RTT) received for
|
|
this hop. A value of 0 for this object implies that no
|
|
RTT has been received."
|
|
::= { traceRouteHopsEntry 5 }
|
|
|
|
traceRouteHopsAverageRtt OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current average traceroute round-trip-time (RTT) for
|
|
this hop."
|
|
::= { traceRouteHopsEntry 6 }
|
|
|
|
traceRouteHopsRttSumOfSquares OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the sum of all traceroute responses
|
|
received for this hop. Its purpose is to enable standard
|
|
deviation calculation."
|
|
::= { traceRouteHopsEntry 7 }
|
|
|
|
traceRouteHopsSentProbes OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object reflects the number of probes sent
|
|
for this hop during this traceroute test. The value of this
|
|
object should start at 0."
|
|
::= { traceRouteHopsEntry 8 }
|
|
|
|
traceRouteHopsProbeResponses OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of responses received for this hop during this
|
|
traceroute test. This value of this object should start
|
|
at 0."
|
|
::= { traceRouteHopsEntry 9 }
|
|
|
|
traceRouteHopsLastGoodProbe OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Date and time was the last response was received for a probe
|
|
for this hop during this traceroute test."
|
|
::= { traceRouteHopsEntry 10 }
|
|
|
|
-- portOpModeSetup
|
|
portOpModeSetup OBJECT IDENTIFIER ::= { es3124 24 }
|
|
|
|
-- portOpModePortTable
|
|
|
|
portOpModePortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PortOpModePortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { portOpModeSetup 1 }
|
|
|
|
portOpModePortEntry OBJECT-TYPE
|
|
SYNTAX PortOpModePortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry in portOpModePortTable."
|
|
INDEX { dot1dBasePort }
|
|
::= { portOpModePortTable 1 }
|
|
|
|
PortOpModePortEntry ::=
|
|
SEQUENCE {
|
|
portOpModePortSpeedDuplex INTEGER,
|
|
portOpModePortFlowCntl INTEGER,
|
|
portOpModePortName OCTET STRING,
|
|
portOpModePortModuleType INTEGER,
|
|
portOpModePortLinkUpType INTEGER,
|
|
portOpModePortIntrusionLock EnabledStatus,
|
|
portOpModePortLBTestStatus INTEGER
|
|
}
|
|
|
|
portOpModePortSpeedDuplex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
auto(0),
|
|
speed-10-half(1),
|
|
speed-10-full(2),
|
|
speed-100-half(3),
|
|
speed-100-full(4),
|
|
speed-1000-full(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { portOpModePortEntry 1 }
|
|
|
|
portOpModePortFlowCntl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { portOpModePortEntry 2 }
|
|
|
|
portOpModePortName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..32))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { portOpModePortEntry 3 }
|
|
|
|
portOpModePortModuleType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fast-ethernet-10-100(0),
|
|
gigabit-ethernet-100-1000(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { portOpModePortEntry 4 }
|
|
|
|
portOpModePortLinkUpType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
copper(1),
|
|
fiber(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { portOpModePortEntry 5 }
|
|
|
|
portOpModePortIntrusionLock OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { portOpModePortEntry 6 }
|
|
|
|
portOpModePortLBTestStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
underTesting(1),
|
|
success(2),
|
|
fail(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry display latest loopback test status of port while performing loopback test."
|
|
::= { portOpModePortEntry 7 }
|
|
|
|
-- portBasedVlanSetup
|
|
portBasedVlanSetup OBJECT IDENTIFIER ::= { es3124 25 }
|
|
|
|
-- portBasedVlanPortListTable
|
|
|
|
portBasedVlanPortListTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PortBasedVlanPortListEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { portBasedVlanSetup 1 }
|
|
|
|
portBasedVlanPortListEntry OBJECT-TYPE
|
|
SYNTAX PortBasedVlanPortListEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry in portBasedVlanPortListTable."
|
|
INDEX { dot1dBasePort }
|
|
::= { portBasedVlanPortListTable 1 }
|
|
|
|
PortBasedVlanPortListEntry ::=
|
|
SEQUENCE {
|
|
portBasedVlanPortListMembers OCTET STRING
|
|
}
|
|
|
|
portBasedVlanPortListMembers OBJECT-TYPE
|
|
SYNTAX PortList
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { portBasedVlanPortListEntry 1 }
|
|
|
|
--fault MIB
|
|
faultMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200411031200Z" -- YYYY/MM/DD, HH/MM
|
|
ORGANIZATION "ZyXEL"
|
|
CONTACT-INFO ""
|
|
DESCRIPTION
|
|
"Fault event table definitions"
|
|
::= { es3124 26 }
|
|
|
|
|
|
-- **************************************************************************
|
|
-- Local Textual Conventions
|
|
-- **************************************************************************
|
|
|
|
UtcTimeStamp ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Universal Time Coordinated as a 32-bit value that designates
|
|
the number of seconds since Jan 1, 1970 12:00AM."
|
|
SYNTAX Unsigned32
|
|
|
|
EventIdNumber ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This textual convention describes the index that uniquely
|
|
identifies a fault event type in the entire system. Every fault
|
|
event type, e.g. link down, has a unique EventIdNumber."
|
|
SYNTAX Integer32
|
|
|
|
EventSeverity ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This textual convention describes the severity of a fault event.
|
|
The decreasing order of severity is shown in the textual
|
|
convention."
|
|
SYNTAX INTEGER{
|
|
critical (1),
|
|
major (2),
|
|
minor (3),
|
|
informational (4)
|
|
}
|
|
|
|
EventServiceAffective ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This textual convention indicates whether an event is immediately
|
|
service affecting or not."
|
|
SYNTAX INTEGER{
|
|
noServiceAffected (1),
|
|
serviceAffected (2)
|
|
}
|
|
|
|
|
|
InstanceType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This textual convention describes the type of an instanceId
|
|
associated with each event and by that means specifies how
|
|
the instanceId variable should be intepreted.
|
|
|
|
Various instanceId types are specified below to enable fault
|
|
monitoring for different kind of devices from fixed
|
|
configuration pizza boxes to multi chassis nodes. All
|
|
instanceId types may not need to be used in every device
|
|
type.
|
|
|
|
Note also that instanceId semantics are element type dependent
|
|
(e.g. different kind of interface naming conventions may be used)
|
|
and thus instanceId usage may vary from element to element.
|
|
|
|
=========================================================================
|
|
Type Description Example form
|
|
of InstanceId
|
|
=========================================================================
|
|
unknown (1) unknown type - Irrelevant-
|
|
-------------------------------------------------------------------------
|
|
node (2) Associated with events originating from 1
|
|
the node. Used for general events that (Node number)
|
|
can not be associated with any specific
|
|
block. InstanceId value 1 is used for
|
|
single node equipment.
|
|
-------------------------------------------------------------------------
|
|
shelf (3) Associated with events originating from 1
|
|
the shelf. In the case of fixed (shelf number)
|
|
configuration devices this type is used
|
|
for events that are associated with the
|
|
physical enclosure, e.g. faults related
|
|
to fan etc. InstanceId value 1 is used
|
|
for single self equipment.
|
|
-------------------------------------------------------------------------
|
|
line (4) Associated with events originating from
|
|
physical interfaces or associated
|
|
components such as line cards.
|
|
InstanceId usage examples for faults
|
|
originating from:
|
|
- Physical port: Simply port number, e.g. .......1
|
|
-------------------------------------------------------------------------
|
|
switch (5) Associated with events originating from 1
|
|
from a switch chip or a switch card. (switch number)
|
|
For single switch equipment InstanceId
|
|
value 1 is used, for multi swich nodes
|
|
InstanceId semantics if for further
|
|
study.
|
|
-------------------------------------------------------------------------
|
|
lsp (6) Associated with events originating from 1
|
|
a particular lsp. (lsp index)
|
|
NOTE: In this case the InstanceName
|
|
contains the lsp name and InstanceId
|
|
contains lsp index.
|
|
-------------------------------------------------------------------------
|
|
l2Interface(7) Associated with events originating from - TBD -
|
|
a particular layer 2 interface. Used for
|
|
layer 2 related events such as L2 control
|
|
protocol faults. InstanceId semantics is
|
|
for further study.
|
|
-------------------------------------------------------------------------
|
|
l3Interface(8) Associated with events originating from - TBD -
|
|
a particular layer 3 interface. Used for
|
|
layer 3 related events such as L3 control
|
|
protocol faults. InstanceId semantics is
|
|
for further study.
|
|
-------------------------------------------------------------------------
|
|
rowIndex (9) Associated with events reporting about a
|
|
'logical' or conceptual table that consists
|
|
of rows. The Instance Id is the index/key
|
|
for a row in the table. The format of the
|
|
Instance Id will simply be a series of decimal
|
|
numbers seperated by a '.':
|
|
========================================================================="
|
|
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
node (2),
|
|
shelf (3),
|
|
line (4),
|
|
switch (5),
|
|
lsp (6),
|
|
l2Interface(7),
|
|
l3Interface(8),
|
|
rowIndex(9)
|
|
}
|
|
|
|
|
|
-- *****************************************************************************
|
|
-- Top level structure of this MIB.
|
|
-- *****************************************************************************
|
|
|
|
eventObjects OBJECT IDENTIFIER ::= { faultMIB 1 }
|
|
|
|
|
|
-- *****************************************************************************
|
|
-- Event Table
|
|
--
|
|
-- Event table reports all currently active fault events. Only normal type of
|
|
-- faults (i.e. faults that are not automatically and immediately cleared) are
|
|
-- present in the event table. Delta faults (i.e. faults that are automatically
|
|
-- cleared) are reported only by using trap messages.
|
|
-- *****************************************************************************
|
|
|
|
eventTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EventEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of currently active fault events. All faults
|
|
of normal type regardless of their severity level
|
|
are recorded in the event table. When a normal
|
|
type fault is cleared it is deleted from the event
|
|
table."
|
|
::= { eventObjects 1 }
|
|
|
|
eventEntry OBJECT-TYPE
|
|
SYNTAX EventEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information about an
|
|
event in the event table."
|
|
INDEX { eventSeqNum }
|
|
::= { eventTable 1 }
|
|
|
|
EventEntry ::=
|
|
SEQUENCE {
|
|
eventSeqNum Integer32,
|
|
eventEventId EventIdNumber,
|
|
eventName DisplayString,
|
|
eventInstanceType InstanceType,
|
|
eventInstanceId DisplayString,
|
|
eventInstanceName DisplayString,
|
|
eventSeverity EventSeverity,
|
|
eventSetTime UtcTimeStamp,
|
|
eventDescription DisplayString,
|
|
eventServAffective EventServiceAffective
|
|
}
|
|
|
|
eventSeqNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable represents the sequence number of an event.
|
|
Sequence number is incremented monotonically starting
|
|
from 0 until it reaches its maximum and wraps around back
|
|
to 0.
|
|
|
|
Sequence number is incremented when
|
|
- the state of a normal type fault is set on (the same sequence
|
|
number is present in the events table as well as in the trap
|
|
that is sent to notify about the fault on event)
|
|
- delta event occurs (sequence number present in trap message)
|
|
- the state of a normal type fault is set off (sequence number
|
|
present in trap that is sent to notify for clearing)."
|
|
::= { eventEntry 1 }
|
|
|
|
eventEventId OBJECT-TYPE
|
|
SYNTAX EventIdNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable represents the event ID which uniquely
|
|
identifies the event in the entire system."
|
|
::= { eventEntry 2 }
|
|
|
|
eventName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..40))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable represents the name of the event, for
|
|
example 'Ethernet Link Down'"
|
|
::= { eventEntry 3 }
|
|
|
|
eventInstanceType OBJECT-TYPE
|
|
SYNTAX InstanceType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable represents the type of InstanceId of a
|
|
particular event in the event table. In brief
|
|
the instanceType refers to the type of sub-component
|
|
generating this event in the system, for example
|
|
switch (5). For more details see the textual
|
|
conventions section.
|
|
|
|
AFFECTS: eventInstanceId,
|
|
eventInstanceName"
|
|
::= { eventEntry 4 }
|
|
|
|
eventInstanceId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable represents the InstanceId of a particular
|
|
event in the event current table. In brief the instanceId
|
|
refers to the sub-component generating this event in the
|
|
system, for example '1' for port 1. For more details see
|
|
the textual conventions section.
|
|
|
|
DEPENDS ON: eventInstanceType"
|
|
::= { eventEntry 5 }
|
|
|
|
eventInstanceName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is mainly used to store additional information
|
|
about the sub-component that is generating an event. For
|
|
example this field may specify what cooling fan is faulty.
|
|
|
|
DEPENDS ON: eventInstanceType"
|
|
::= { eventEntry 6 }
|
|
|
|
eventSeverity OBJECT-TYPE
|
|
SYNTAX EventSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable dictates the urgency of action when a event
|
|
occurs. There are four severity levels - Critical, Major,
|
|
Minor, and Informational. Critical events are those, which
|
|
require immediate operator intervention to prevent/reduce
|
|
system down time. Major events require quick attention and
|
|
Minor events possibly require some attention. Informational
|
|
events indicate the occurrence of events that may need to be
|
|
investigated."
|
|
::= { eventEntry 7 }
|
|
|
|
eventSetTime OBJECT-TYPE
|
|
SYNTAX UtcTimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains only normal events and this variable
|
|
represents the time when the event become active, i.e. the
|
|
number of seconds since Jan 1, 1970 12:00AM."
|
|
::= { eventEntry 8 }
|
|
|
|
|
|
eventDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable contains a description of the event and reasons
|
|
behind the event. This is a free format alpha-numeric string
|
|
that is set by the entity generating this event. This variable
|
|
may be empty if there is no usefull information to report.
|
|
The maximum length of this string is 255 characters."
|
|
::= { eventEntry 9 }
|
|
|
|
eventServAffective OBJECT-TYPE
|
|
SYNTAX EventServiceAffective
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates whether the event is service affective or not"
|
|
::= { eventEntry 10 }
|
|
|
|
|
|
-- fault Trap MIB
|
|
faultTrapsMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200411011200Z" -- YYYY/MM/DD, HH/MM
|
|
ORGANIZATION "ZyXEL"
|
|
CONTACT-INFO ""
|
|
DESCRIPTION
|
|
"Fault event trap definitions"
|
|
::= { es3124 27 }
|
|
|
|
trapInfoObjects OBJECT IDENTIFIER ::= { faultTrapsMIB 1}
|
|
trapNotifications OBJECT IDENTIFIER ::= { faultTrapsMIB 2}
|
|
|
|
|
|
-- **************************************************************************
|
|
-- Local Textual Conventions
|
|
-- **************************************************************************
|
|
|
|
EventPersistence ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This textual convention indicates whether the event is delta
|
|
(automatically and immediately cleared) or normal (not
|
|
automatically cleared)."
|
|
SYNTAX INTEGER{
|
|
normal (1),
|
|
delta (2)
|
|
}
|
|
|
|
|
|
-- **************************************************************************
|
|
-- Trap information object definitions
|
|
-- **************************************************************************
|
|
|
|
trapRefSeqNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the former sequence number of a cleared event
|
|
in the event table. Not intended to read but only used in
|
|
trap notifications."
|
|
::= { trapInfoObjects 1 }
|
|
|
|
trapPersistence OBJECT-TYPE
|
|
SYNTAX EventPersistence
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the event is delta (automatically and
|
|
immediately cleared) or normal (not automatically cleared).
|
|
Not intended to read but only used in trap notifications."
|
|
::= { trapInfoObjects 2 }
|
|
|
|
trapSenderNodeId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Represents the node ID of the sending network element. If not
|
|
supported should be set to 0. Not intended to read but only
|
|
used in trap notifications."
|
|
::= { trapInfoObjects 3 }
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- Trap definitions
|
|
-- ***************************************************************************
|
|
|
|
eventOnTrap NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
eventSeqNum,
|
|
eventEventId,
|
|
eventName,
|
|
eventSetTime,
|
|
eventSeverity,
|
|
eventInstanceType,
|
|
eventInstanceId,
|
|
eventInstanceName,
|
|
eventServAffective,
|
|
eventDescription,
|
|
trapPersistence,
|
|
trapSenderNodeId,
|
|
sysObjectID}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is used to inform network management system that a delta
|
|
fault event (events that are automatically cleared) has occured
|
|
or a normal fault event (not automatically cleared) state has
|
|
been set on.
|
|
|
|
Objects are used as follows:
|
|
- eventSeqNum is the sequence number of the event. For normal
|
|
type of events must equal to the sequence number of the event
|
|
in the events table.
|
|
- eventEventId specifies what fault event has occured.
|
|
- eventName specifies the name of the fault event.
|
|
- eventSetTime indicates when fault event has occured
|
|
(delta events) or when fault has been set on (normal events).
|
|
- eventSeverity reports the severity level of the event.
|
|
- eventInstanceType indicates what kind of object is faulty.
|
|
- eventInstanceId specifies what instance is faulty.
|
|
- eventInstanceName may contain textual description for
|
|
the faulty object.
|
|
- eventServAffective specifies whether the event is
|
|
immediately service affcetive.
|
|
- eventDescription reports possible additional information about the event.
|
|
- trapPersistence tells whether this event is a delta or normal event.
|
|
- trapSenderNodeId specifies the node ID of the sending network element if
|
|
configuring it is supported for the network element, otherwise 0.
|
|
- sysObjectID specifies what kind of equipment reports the fault event.
|
|
|
|
For more information see the eventTable specification"
|
|
::= { trapNotifications 1 }
|
|
|
|
eventClearedTrap NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
eventSeqNum,
|
|
eventEventId,
|
|
eventSetTime,
|
|
eventInstanceType,
|
|
eventInstanceId,
|
|
trapRefSeqNum,
|
|
trapSenderNodeId,
|
|
sysObjectID}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is used to inform network management system that a normal
|
|
type fault event has been cleared (state set off).
|
|
|
|
Objects are used as follows:
|
|
- eventSeqNum is the sequence number of the this clearing event. Note that
|
|
the sequence number of the cleared event is reported in the trapRefSeqNum
|
|
object.
|
|
- eventEventId specifies what event has been cleared.
|
|
- eventSetTime indicates when fault event has been cleared.
|
|
- eventInstanceType indicates what kind of object has been
|
|
faulty.
|
|
- eventInstanceId specifies what instance has been faulty.
|
|
- trapRefSeqNum specifies the sequence number of the cleared event (i.e.
|
|
the sequence number was assigned for the event in the events table).
|
|
- trapSenderNodeId specifies the node ID of the sending network element if
|
|
configuring it is supported for the network element, otherwise 0.
|
|
- sysObjectID specifies what kind of equipment reports the clearing event.
|
|
|
|
For more information see the eventTable specification"
|
|
::= { trapNotifications 2 }
|
|
|
|
|
|