Observium_CE/mibs/zyxel/ZYXEL-ES2108G-MIB

5234 lines
154 KiB
Plaintext

ZYXEL-ES2108G-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises FROM RFC1155-SMI
OBJECT-TYPE
FROM SNMPv2-SMI -- RFC2578
RowStatus, DateAndTime, TruthValue, StorageType, MacAddress
FROM SNMPv2-TC -- RFC2579
DisplayString
FROM RFC1213-MIB
EnabledStatus
FROM P-BRIDGE-MIB
PortList
FROM Q-BRIDGE-MIB
dot1dBasePort
FROM BRIDGE-MIB
InterfaceIndexOrZero -- RFC2863
FROM IF-MIB
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB -- RFC2571
InetAddressType, InetAddress
FROM INET-ADDRESS-MIB -- RFC2851
OperationResponseStatus
FROM DISMAN-PING-MIB
Counter, TimeTicks
FROM RFC1155-SMI
BridgeId, Timeout
FROM BRIDGE-MIB
IpAddress
FROM SNMPv2-SMI
NOTIFICATION-TYPE
FROM SNMPv2-SMI
sysObjectID
FROM RFC1213-MIB;
zyxel OBJECT IDENTIFIER ::= { enterprises 890 }
products OBJECT IDENTIFIER ::= { zyxel 1 }
accessSwitch OBJECT IDENTIFIER ::= { products 5 }
esSeries OBJECT IDENTIFIER ::= { accessSwitch 8 }
es2108g OBJECT IDENTIFIER ::= { esSeries 19 }
-- sysInfo
sysInfo OBJECT IDENTIFIER ::= { es2108g 1 }
sysSwPlatformMajorVers OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SW platform major version, e.g. 3."
::= { sysInfo 1 }
sysSwPlatformMinorVers OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SW platform minor version, e.g. 50."
::= { sysInfo 2 }
sysSwModelString OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model letters, e.g. TJ"
::= { sysInfo 3 }
sysSwVersionControlNbr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Version control number, e.g. 0."
::= { sysInfo 4 }
sysSwDay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SW compilation day, e.g. 19."
::= { sysInfo 5 }
sysSwMonth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SW compilation month, e.g. 8."
::= { sysInfo 6 }
sysSwYear OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SW compilation year, e.g. 2004."
::= { sysInfo 7 }
sysHwMajorVers OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"HW major version number, e.g. 1."
::= { sysInfo 8 }
sysHwMinorVers OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"HW minor version number, e.g. 0."
::= { sysInfo 9 }
sysSerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serial number"
::= { sysInfo 10 }
-- rateLimitSetup
rateLimitSetup OBJECT IDENTIFIER ::= { es2108g 2 }
rateLimitState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ingress/egress rate limiting enabled/disabled for the switch."
::= { rateLimitSetup 1 }
-- rateLimitPortTable
rateLimitPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF RateLimitPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { rateLimitSetup 2 }
rateLimitPortEntry OBJECT-TYPE
SYNTAX RateLimitPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in rateLimitPortTable."
INDEX { dot1dBasePort }
::= { rateLimitPortTable 1 }
RateLimitPortEntry ::=
SEQUENCE {
rateLimitPortState EnabledStatus,
rateLimitPortIngRate INTEGER,
rateLimitPortEgrRate INTEGER,
rateLimitPortStateIngress EnabledStatus,
rateLimitPortStateEgress EnabledStatus
}
rateLimitPortState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ingress/egress rate limiting enabled/disabled on the port."
::= { rateLimitPortEntry 1 }
rateLimitPortIngRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ingress rate in Kbit/s. The range of FE port is between 64 and 100,000. For GE port, the range is between 64 and 1000,000."
::= { rateLimitPortEntry 2 }
rateLimitPortEgrRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Egress rate in Kbit/s. The range of FE port is between 64 and 100,000. For GE port, the range is between 64 and 1000,000."
::= { rateLimitPortEntry 3 }
rateLimitPortStateIngress OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ingress rate limiting enabled/disabled on the port."
::= { rateLimitPortEntry 5 }
rateLimitPortStateEgress OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Egress rate limiting enabled/disabled on the port."
::= { rateLimitPortEntry 6 }
-- brLimitSetup
brLimitSetup OBJECT IDENTIFIER ::= { es2108g 3 }
brLimitState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Broadcast/multicast/DLF rate limiting enabled/disabled for the switch."
::= { brLimitSetup 1 }
-- brLimitPortTable
brLimitPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF BrLimitPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { brLimitSetup 2 }
brLimitPortEntry OBJECT-TYPE
SYNTAX BrLimitPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in brLimitPortTable."
INDEX { dot1dBasePort }
::= { brLimitPortTable 1 }
BrLimitPortEntry ::=
SEQUENCE {
brLimitPortState EnabledStatus,
brLimitPortRate INTEGER
}
brLimitPortState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rate limiting enabled/disabled on the port."
::= { brLimitPortEntry 1 }
brLimitPortRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Allowed rate in in Kbit/s. The range of FE port is between 64 and 100,000. For GE port, the range is between 64 and 1000,000."
::= { brLimitPortEntry 2 }
-- portSecuritySetup
portSecuritySetup OBJECT IDENTIFIER ::= { es2108g 4 }
portSecurityState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { portSecuritySetup 1 }
portSecurityPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortSecurityPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { portSecuritySetup 2 }
portSecurityPortEntry OBJECT-TYPE
SYNTAX PortSecurityPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in portSecurityPortTable."
INDEX { dot1dBasePort }
::= { portSecurityPortTable 1 }
PortSecurityPortEntry ::=
SEQUENCE {
portSecurityPortState EnabledStatus,
portSecurityPortLearnState EnabledStatus,
portSecurityPortCount INTEGER
}
portSecurityPortState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port Security enabled/disabled on the port.
Active(1) means this port only accept frames from static MAC addresses that are configured for the port,
and dynamic MAC address frames up to the number specified by portSecurityPortCount object."
::= { portSecurityPortEntry 1 }
portSecurityPortLearnState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"MAC address learning enabled/disable on the port."
::= { portSecurityPortEntry 2 }
portSecurityPortCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of (dynamic) MAC addresses that may be learned on the port."
::= { portSecurityPortEntry 3 }
portSecurityMacFreeze OBJECT-TYPE
SYNTAX PortList
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This entry is used to execute MacFreeze action to port.
It's meaningless while reading this entry."
::= { portSecuritySetup 3 }
-- vlanTrunkPortTable
vlanTrunkSetup OBJECT IDENTIFIER ::= { es2108g 5 }
vlanTrunkPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF VlanTrunkPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { vlanTrunkSetup 1 }
vlanTrunkPortEntry OBJECT-TYPE
SYNTAX VlanTrunkPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in vlanTrunkPortTable."
INDEX { dot1dBasePort }
::= { vlanTrunkPortTable 1 }
VlanTrunkPortEntry ::=
SEQUENCE {
vlanTrunkPortState EnabledStatus
}
vlanTrunkPortState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"VlanTrunking enabled/disabled on the port.
Active(1) to allow frames belonging to unknown
VLAN groups to pass through the switch."
::= { vlanTrunkPortEntry 1 }
-- dot1xSetup
dot1xSetup OBJECT IDENTIFIER ::= { es2108g 6 }
-- portAuthState
portAuthState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"802.1x port authentication enabled/disabled for the switch."
::= { dot1xSetup 3 }
-- portAuthTable
portAuthTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortAuthEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { dot1xSetup 4 }
portAuthEntry OBJECT-TYPE
SYNTAX PortAuthEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in portAuthTable."
INDEX { dot1dBasePort }
::= { portAuthTable 1 }
PortAuthEntry ::=
SEQUENCE {
portAuthEntryState EnabledStatus,
portReAuthEntryState EnabledStatus,
portReAuthEntryTimer INTEGER
}
portAuthEntryState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"802.1x port authentication enabled or disabled on the port."
::= { portAuthEntry 1 }
portReAuthEntryState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"802.1x port re-authentication enabled or disabled on the port."
::= { portAuthEntry 2 }
portReAuthEntryTimer OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Re-authentication timer in seconds."
::= { portAuthEntry 3 }
-- snmpSetup
snmpSetup OBJECT IDENTIFIER ::= { es2108g 7 }
snmpGetCommunity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { snmpSetup 1 }
snmpSetCommunity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { snmpSetup 2 }
snmpTrapCommunity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { snmpSetup 3 }
-- snmpTrapDestTable
snmpTrapDestTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnmpTrapDestEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { snmpSetup 4 }
snmpTrapDestEntry OBJECT-TYPE
SYNTAX SnmpTrapDestEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in snmpTrapDestTable."
INDEX { snmpTrapDestIP }
::= { snmpTrapDestTable 1 }
SnmpTrapDestEntry ::=
SEQUENCE {
snmpTrapDestIP IpAddress,
snmpTrapDestRowStatus RowStatus,
snmpTrapDestPort INTEGER,
snmpTrapVersion INTEGER,
snmpTrapUserName DisplayString
}
snmpTrapDestIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"IP address of trap destination."
::= { snmpTrapDestEntry 1 }
snmpTrapDestRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { snmpTrapDestEntry 2 }
snmpTrapDestPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"The UDP port of the trap destination."
::= { snmpTrapDestEntry 3 }
snmpTrapVersion OBJECT-TYPE
SYNTAX INTEGER {
v1(0),
v2c(1),
v3(2)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"The SNMP protocol version to send traps."
::= { snmpTrapDestEntry 4 }
snmpTrapUserName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user name for sending SNMPv3 traps."
::= { snmpTrapDestEntry 5 }
snmpVersion OBJECT-TYPE
SYNTAX INTEGER {
v2c(0),
v3(1),
v3v2c(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The SNMP version to be used. v3v2c means that the manager
can get/set by SNMPv3 and can get by SNMPv2c."
::= { snmpSetup 5 }
-- snmpUserTable
snmpUserTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnmpUserEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains SNMPv3 user information."
::= { snmpSetup 6 }
snmpUserEntry OBJECT-TYPE
SYNTAX SnmpUserEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of snmpUserTable."
INDEX { snmpUserName }
::= { snmpUserTable 1 }
SnmpUserEntry ::=
SEQUENCE {
snmpUserName DisplayString,
snmpUserSecurityLevel INTEGER,
snmpUserAuthProtocol INTEGER,
snmpUserPrivProtocol INTEGER
}
snmpUserName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user name."
::= { snmpUserEntry 1 }
snmpUserSecurityLevel OBJECT-TYPE
SYNTAX INTEGER {
noAuthNoPriv(0),
authNoPriv(1),
authPriv(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The level of security at which SNMP messages can be sent or
with which operations are being processed."
::= { snmpUserEntry 2 }
snmpUserAuthProtocol OBJECT-TYPE
SYNTAX INTEGER {
md5(0),
sha(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of authentication protocol to be used."
::= { snmpUserEntry 3 }
snmpUserPrivProtocol OBJECT-TYPE
SYNTAX INTEGER {
des(0),
aes(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of privacy protocol to be used."
::= { snmpUserEntry 4 }
-- snmpTrapGroupTable
snmpTrapGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnmpTrapGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { snmpSetup 7 }
snmpTrapGroupEntry OBJECT-TYPE
SYNTAX SnmpTrapGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in snmpTrapGroupTable."
INDEX { snmpTrapDestIP }
::= { snmpTrapGroupTable 1 }
SnmpTrapGroupEntry ::=
SEQUENCE {
snmpTrapSystemGroup BITS,
snmpTrapInterfaceGroup BITS,
snmpTrapAAAGroup BITS,
snmpTrapIPGroup BITS,
snmpTrapSwitchGroup BITS
}
snmpTrapSystemGroup OBJECT-TYPE
SYNTAX BITS {
coldStart(0),
warmStart(1),
reset (5),
timeSync (6),
intrusionlock(7),
loopGuard(13)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { snmpTrapGroupEntry 1 }
snmpTrapInterfaceGroup OBJECT-TYPE
SYNTAX BITS {
linkup(0),
linkdown(1),
autonegotiation(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { snmpTrapGroupEntry 2 }
snmpTrapAAAGroup OBJECT-TYPE
SYNTAX BITS {
authentication(0),
accounting(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { snmpTrapGroupEntry 3 }
snmpTrapIPGroup OBJECT-TYPE
SYNTAX BITS {
ping(0),
traceroute(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { snmpTrapGroupEntry 4 }
snmpTrapSwitchGroup OBJECT-TYPE
SYNTAX BITS {
stp(0),
mactable(1),
rmon(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { snmpTrapGroupEntry 5 }
-- dateTimeSetup
dateTimeSetup OBJECT IDENTIFIER ::= { es2108g 8 }
dateTimeServerType OBJECT-TYPE
SYNTAX INTEGER {
none(1),
daytime(2),
time(3),
ntp(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time service protocol."
::= { dateTimeSetup 1 }
dateTimeServerIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of time server."
::= { dateTimeSetup 2 }
dateTimeZone OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time difference between UTC. Ex: +01"
::= { dateTimeSetup 3 }
dateTimeNewDateYear OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The new date in year."
::= { dateTimeSetup 4 }
dateTimeNewDateMonth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The new date in month."
::= { dateTimeSetup 5 }
dateTimeNewDateDay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The new date in day."
::= { dateTimeSetup 6 }
dateTimeNewTimeHour OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The new time in hour."
::= { dateTimeSetup 7 }
dateTimeNewTimeMinute OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The new time in minute."
::= { dateTimeSetup 8 }
dateTimeNewTimeSecond OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The new time in second."
::= { dateTimeSetup 9 }
-- dateTimeDaylightSavingTimeSetup OBJECT-TYPE
dateTimeDaylightSavingTimeSetup OBJECT IDENTIFIER ::= { dateTimeSetup 10 }
daylightSavingTimeState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Daylight saving time service enabled/disabled for the switch."
::= { dateTimeDaylightSavingTimeSetup 1 }
daylightSavingTimeStartDateWeek OBJECT-TYPE
SYNTAX INTEGER {
first(1),
second(2),
third(3),
fourth(4),
last(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Daylight saving time service start week."
::= { dateTimeDaylightSavingTimeSetup 2 }
daylightSavingTimeStartDateDay OBJECT-TYPE
SYNTAX INTEGER {
sunday(0),
monday(1),
tuesday(2),
wednesday(3),
thursday(4),
friday(5),
saturday(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Daylight saving time service start day."
::= { dateTimeDaylightSavingTimeSetup 3 }
daylightSavingTimeStartDateMonth OBJECT-TYPE
SYNTAX INTEGER {
january(1),
february(2),
march(3),
april(4),
may(5),
june(6),
july(7),
august(8),
september(9),
october(10),
november(11),
december(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Daylight saving time service start month."
::= { dateTimeDaylightSavingTimeSetup 4 }
daylightSavingTimeStartDateHour OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Daylight saving time service start time."
::= { dateTimeDaylightSavingTimeSetup 5 }
daylightSavingTimeEndDateWeek OBJECT-TYPE
SYNTAX INTEGER {
first(1),
second(2),
third(3),
fourth(4),
last(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Daylight saving time service end week."
::= { dateTimeDaylightSavingTimeSetup 6 }
daylightSavingTimeEndDateDay OBJECT-TYPE
SYNTAX INTEGER {
sunday(0),
monday(1),
tuesday(2),
wednesday(3),
thursday(4),
friday(5),
saturday(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Daylight saving time service end day."
::= { dateTimeDaylightSavingTimeSetup 7 }
daylightSavingTimeEndDateMonth OBJECT-TYPE
SYNTAX INTEGER {
january(1),
february(2),
march(3),
april(4),
may(5),
june(6),
july(7),
august(8),
september(9),
october(10),
november(11),
december(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Daylight saving time service end month."
::= { dateTimeDaylightSavingTimeSetup 8 }
daylightSavingTimeEndDateHour OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Daylight saving time service end time."
::= { dateTimeDaylightSavingTimeSetup 9 }
-- sysMgmt
sysMgmt OBJECT IDENTIFIER ::= { es2108g 9 }
sysMgmtConfigSave OBJECT-TYPE
SYNTAX INTEGER {
config(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If setting value is given, the variable write index will be set and running-config will be written to the assigned configuration file.
If not, running-config will be written to the booting one."
::= { sysMgmt 1 }
sysMgmtBootupConfig OBJECT-TYPE
SYNTAX INTEGER {
config(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The setting value (read index) will be written into non-volatile memory.
While rebooting, the variable write index is equal to read index initially.
You can change the value of write index by CLI / MIB."
::= { sysMgmt 2 }
sysMgmtReboot OBJECT-TYPE
SYNTAX INTEGER {
nothing(0),
reboot(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reboot switch from SNMP. 1:Reboot, 0:Nothing"
::= { sysMgmt 3 }
sysMgmtDefaultConfig OBJECT-TYPE
SYNTAX INTEGER {
nothing(0),
reset_to_default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Erase running config and reset to default."
::= { sysMgmt 4 }
sysMgmtLastActionStatus OBJECT-TYPE
SYNTAX INTEGER {
none(0),
success(1),
fail(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display status of last mgmt action."
::= { sysMgmt 5 }
-- layer2Setup
layer2Setup OBJECT IDENTIFIER ::= { es2108g 10 }
vlanTypeSetup OBJECT-TYPE
SYNTAX INTEGER {
dot1Q(1),
port_based(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 1 }
igmpSnoopingStateSetup OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 2 }
tagVlanPortIsolationState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 3 }
stpState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 4 }
tagVlanIngressCheckState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 5 }
igmpFilteringStateSetup OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 6 }
unknownMulticastFrameForwarding OBJECT-TYPE
SYNTAX INTEGER {
flooding(1),
drop(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 7 }
multicastGrpHostTimeOut OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 8 }
multicastGrpLeaveTimeOut OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 9 }
igmpsnp8021pPriority OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set the 802.1p priority of control messages for igmp-snooping(0~8, 8-No Change)"
::= { layer2Setup 10 }
igmpsnpVlanMode OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
fixed(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 11 }
stpMode OBJECT-TYPE
SYNTAX INTEGER {
rstp(1),
mstp(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 12 }
-- igmpsnpVlanTable
igmpsnpVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpsnpVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 13 }
igmpsnpVlanEntry OBJECT-TYPE
SYNTAX IgmpsnpVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in IgmpsnpVlanTable."
INDEX { igmpsnpVid }
::= { igmpsnpVlanTable 1 }
IgmpsnpVlanEntry ::=
SEQUENCE {
igmpsnpVid INTEGER,
igmpsnpVlanName DisplayString,
igmpsnpVlanRowStatus RowStatus
}
igmpsnpVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpsnpVlanEntry 1 }
igmpsnpVlanName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { igmpsnpVlanEntry 2 }
igmpsnpVlanRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { igmpsnpVlanEntry 3 }
igmpsnpQuerierMode OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 14 }
-- ipSetup
ipSetup OBJECT IDENTIFIER ::= { es2108g 11 }
dnsIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { ipSetup 1 }
defaultMgmtIpSetup OBJECT IDENTIFIER ::= { ipSetup 2 }
defaultMgmtIpType OBJECT-TYPE
SYNTAX INTEGER {
dhcp_client(0),
static_ip(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { defaultMgmtIpSetup 1 }
defaultMgmtVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { defaultMgmtIpSetup 2 }
defaultMgmtStaticIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { defaultMgmtIpSetup 3 }
defaultMgmtStaticSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { defaultMgmtIpSetup 4 }
defaultMgmtStaticGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { defaultMgmtIpSetup 5 }
-- inbandIpTable
maxNumOfMgmtIp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ipSetup 3 }
mgmtIpTable OBJECT-TYPE
SYNTAX SEQUENCE OF MgmtIpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { ipSetup 6 }
mgmtIpEntry OBJECT-TYPE
SYNTAX MgmtIpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in mgmtIpTable."
INDEX { mgmtEntryIp, mgmtEntryVid }
::= { mgmtIpTable 1 }
MgmtIpEntry ::=
SEQUENCE {
mgmtEntryIp IpAddress,
mgmtEntrySubnetMask IpAddress,
mgmtEntryGateway IpAddress,
mgmtEntryVid INTEGER,
mgmtEntryManageable EnabledStatus,
mgmtEntryRowStatus RowStatus
}
mgmtEntryIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mgmtIpEntry 1 }
mgmtEntrySubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mgmtIpEntry 2 }
mgmtEntryGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mgmtIpEntry 3 }
mgmtEntryVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { mgmtIpEntry 4 }
mgmtEntryManageable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mgmtIpEntry 5 }
mgmtEntryRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { mgmtIpEntry 6 }
-- filterSetup
filterSetup OBJECT IDENTIFIER ::= { es2108g 12 }
-- filterTable
filterTable OBJECT-TYPE
SYNTAX SEQUENCE OF FilterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { filterSetup 1 }
filterEntry OBJECT-TYPE
SYNTAX FilterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in filterTable."
INDEX { filterMacAddr, filterVid }
::= { filterTable 1 }
FilterEntry ::=
SEQUENCE {
filterName DisplayString,
filterMacAddr MacAddress,
filterVid INTEGER,
filterRowStatus RowStatus
}
filterName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { filterEntry 1 }
filterMacAddr OBJECT-TYPE
SYNTAX MacAddress
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { filterEntry 2 }
filterVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { filterEntry 3 }
filterRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { filterEntry 4 }
-- mirrorSetup
mirrorSetup OBJECT IDENTIFIER ::= { es2108g 13 }
-- mirrorState
mirrorState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mirrorSetup 1 }
mirrorMonitorPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mirrorSetup 2 }
mirrorIngActionState OBJECT-TYPE
SYNTAX INTEGER {
all(0),
destination_mac(1),
source_mac(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mirrorSetup 3 }
mirrorIngMacAddr OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mirrorSetup 4 }
mirrorEgrActionState OBJECT-TYPE
SYNTAX INTEGER {
all(0),
destination_mac(1),
source_mac(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mirrorSetup 5 }
mirrorEgrMacAddr OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mirrorSetup 6 }
-- mirrorTable
mirrorTable OBJECT-TYPE
SYNTAX SEQUENCE OF MirrorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { mirrorSetup 7 }
mirrorEntry OBJECT-TYPE
SYNTAX MirrorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in mirrorTable."
INDEX { dot1dBasePort }
::= { mirrorTable 1 }
MirrorEntry ::=
SEQUENCE {
mirrorMirroredState EnabledStatus,
mirrorDirection INTEGER
}
mirrorMirroredState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mirrorEntry 1 }
mirrorDirection OBJECT-TYPE
SYNTAX INTEGER {
ingress(0),
egress(1),
both(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mirrorEntry 2 }
-- aggrSetup
aggrSetup OBJECT IDENTIFIER ::= { es2108g 14 }
aggrState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { aggrSetup 1 }
aggrSystemPriority OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { aggrSetup 2 }
-- aggrGroupTable
aggrGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF AggrGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { aggrSetup 3 }
aggrGroupEntry OBJECT-TYPE
SYNTAX AggrGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in aggrGroupTable."
INDEX { aggrGroupIndex }
::= { aggrGroupTable 1 }
AggrGroupEntry ::=
SEQUENCE {
aggrGroupIndex INTEGER,
aggrGroupState EnabledStatus,
aggrGroupDynamicState EnabledStatus
}
aggrGroupIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { aggrGroupEntry 1 }
aggrGroupState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { aggrGroupEntry 2 }
aggrGroupDynamicState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { aggrGroupEntry 3 }
-- aggrPortTable
aggrPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF AggrPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { aggrSetup 4 }
aggrPortEntry OBJECT-TYPE
SYNTAX AggrPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in aggrPortTable."
INDEX { dot1dBasePort }
::= { aggrPortTable 1 }
AggrPortEntry ::=
SEQUENCE {
aggrPortGroup INTEGER,
aggrPortDynamicStateTimeout INTEGER
}
aggrPortGroup OBJECT-TYPE
SYNTAX INTEGER {
none(0),
t1(1),
t2(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { aggrPortEntry 1 }
aggrPortDynamicStateTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { aggrPortEntry 2 }
-- accessCtlSetup
accessCtlSetup OBJECT IDENTIFIER ::= { es2108g 15 }
-- accessCtlTable
accessCtlTable OBJECT-TYPE
SYNTAX SEQUENCE OF AccessCtlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { accessCtlSetup 1 }
accessCtlEntry OBJECT-TYPE
SYNTAX AccessCtlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in accessCtlTable."
INDEX { accessCtlService }
::= { accessCtlTable 1 }
AccessCtlEntry ::=
SEQUENCE {
accessCtlService INTEGER,
accessCtlEnable EnabledStatus,
accessCtlServicePort INTEGER,
accessCtlTimeout INTEGER
}
accessCtlService OBJECT-TYPE
SYNTAX INTEGER {
telnet(1),
ssh(2),
ftp(3),
http(4),
https(5),
icmp(6),
snmp(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { accessCtlEntry 1 }
accessCtlEnable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { accessCtlEntry 2 }
accessCtlServicePort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { accessCtlEntry 3 }
accessCtlTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { accessCtlEntry 4 }
-- securedClientTable
securedClientTable OBJECT-TYPE
SYNTAX SEQUENCE OF SecuredClientEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { accessCtlSetup 2 }
securedClientEntry OBJECT-TYPE
SYNTAX SecuredClientEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in securedClientTable."
INDEX { securedClientIndex }
::= { securedClientTable 1 }
SecuredClientEntry ::=
SEQUENCE {
securedClientIndex INTEGER,
securedClientEnable EnabledStatus,
securedClientStartIp IpAddress,
securedClientEndIp IpAddress,
securedClientService BITS
}
securedClientIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { securedClientEntry 1 }
securedClientEnable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { securedClientEntry 2 }
securedClientStartIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { securedClientEntry 3 }
securedClientEndIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { securedClientEntry 4 }
securedClientService OBJECT-TYPE
SYNTAX BITS {
telnet(0),
ftp(1),
http(2),
icmp(3),
snmp(4),
ssh(5),
https(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { securedClientEntry 5 }
-- queuingMethodSetup
queuingMethodSetup OBJECT IDENTIFIER ::= { es2108g 16 }
queuingMethodType OBJECT-TYPE
SYNTAX INTEGER {
strictly_priority(0),
weighted_round_robin_scheduling(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { queuingMethodSetup 1 }
-- QueuingMethodTable
queuingMethodTable OBJECT-TYPE
SYNTAX SEQUENCE OF QueuingMethodEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { queuingMethodSetup 2 }
queuingMethodEntry OBJECT-TYPE
SYNTAX QueuingMethodEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in queuingMethodTable."
INDEX { queuingMethodQueue }
::= {queuingMethodTable 1}
QueuingMethodEntry ::=
SEQUENCE {
queuingMethodQueue INTEGER,
queuingMethodWeight INTEGER
}
queuingMethodQueue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"0...3"
::= { queuingMethodEntry 1 }
queuingMethodWeight OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"1...15"
::= { queuingMethodEntry 2 }
-- staticRouteSetup
staticRouteSetup OBJECT IDENTIFIER ::= { es2108g 17 }
maxNumberOfStaticRoutes OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { staticRouteSetup 1 }
-- staticRouteTable
staticRouteTable OBJECT-TYPE
SYNTAX SEQUENCE OF StaticRouteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { staticRouteSetup 2 }
staticRouteEntry OBJECT-TYPE
SYNTAX StaticRouteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in staticRouteTable."
INDEX { staticRouteIp, staticRouteMask }
::= { staticRouteTable 1 }
StaticRouteEntry ::=
SEQUENCE {
staticRouteName DisplayString,
staticRouteIp IpAddress,
staticRouteMask IpAddress,
staticRouteGateway IpAddress,
staticRouteMetric INTEGER,
staticRouteRowStatus RowStatus
}
staticRouteName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { staticRouteEntry 1 }
staticRouteIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { staticRouteEntry 2 }
staticRouteMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { staticRouteEntry 3 }
staticRouteGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { staticRouteEntry 4 }
staticRouteMetric OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { staticRouteEntry 5 }
staticRouteRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { staticRouteEntry 6 }
-- arpInfo
arpInfo OBJECT IDENTIFIER ::= { es2108g 18 }
-- arpTable
arpTable OBJECT-TYPE
SYNTAX SEQUENCE OF ArpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { arpInfo 1 }
arpEntry OBJECT-TYPE
SYNTAX ArpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in arpTable."
INDEX { arpIpAddr, arpMacVid }
::= { arpTable 1 }
ArpEntry ::=
SEQUENCE {
arpIndex INTEGER,
arpIpAddr IpAddress,
arpMacAddr MacAddress,
arpMacVid INTEGER,
arpType INTEGER
}
arpIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpEntry 1 }
arpIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpEntry 2 }
arpMacAddr OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpEntry 3 }
arpMacVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpEntry 4 }
arpType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpEntry 5 }
-- portOpModeSetup
portOpModeSetup OBJECT IDENTIFIER ::= { es2108g 19 }
-- portOpModePortTable
portOpModePortTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortOpModePortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { portOpModeSetup 1 }
portOpModePortEntry OBJECT-TYPE
SYNTAX PortOpModePortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in portOpModePortTable."
INDEX { dot1dBasePort }
::= { portOpModePortTable 1 }
PortOpModePortEntry ::=
SEQUENCE {
portOpModePortSpeedDuplex INTEGER,
portOpModePortFlowCntl INTEGER,
portOpModePortName OCTET STRING,
portOpModePortModuleType INTEGER,
portOpModePortLinkUpType INTEGER,
portOpModePortIntrusionLock EnabledStatus,
portOpModePortLBTestStatus INTEGER
}
portOpModePortSpeedDuplex OBJECT-TYPE
SYNTAX INTEGER {
auto(0),
speed_10_half(1),
speed_10_full(2),
speed_100_half(3),
speed_100_full(4),
speed_1000_full(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { portOpModePortEntry 1 }
portOpModePortFlowCntl OBJECT-TYPE
SYNTAX INTEGER {
off(0),
on(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { portOpModePortEntry 2 }
portOpModePortName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { portOpModePortEntry 3 }
portOpModePortModuleType OBJECT-TYPE
SYNTAX INTEGER {
fast_ethernet_10_100(0),
gigabit_ethernet_100_1000(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { portOpModePortEntry 4 }
portOpModePortLinkUpType OBJECT-TYPE
SYNTAX INTEGER {
down(0),
copper(1),
fiber(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { portOpModePortEntry 5 }
portOpModePortIntrusionLock OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { portOpModePortEntry 6 }
portOpModePortLBTestStatus OBJECT-TYPE
SYNTAX INTEGER {
none(0),
underTesting(1),
success(2),
fail(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This entry display latest loopback test status of port while performing loopback test."
::= { portOpModePortEntry 7 }
-- portBasedVlanSetup
portBasedVlanSetup OBJECT IDENTIFIER ::= { es2108g 20 }
-- portBasedVlanPortListTable
portBasedVlanPortListTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortBasedVlanPortListEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { portBasedVlanSetup 1 }
portBasedVlanPortListEntry OBJECT-TYPE
SYNTAX PortBasedVlanPortListEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in portBasedVlanPortListTable."
INDEX { dot1dBasePort }
::= { portBasedVlanPortListTable 1 }
PortBasedVlanPortListEntry ::=
SEQUENCE {
portBasedVlanPortListMembers OCTET STRING
}
portBasedVlanPortListMembers OBJECT-TYPE
SYNTAX PortList
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { portBasedVlanPortListEntry 1 }
-- diffservSetup
diffservSetup OBJECT IDENTIFIER ::= { es2108g 21 }
diffservState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { diffservSetup 1 }
-- diffservMapTable
diffservMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF DiffservMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { diffservSetup 2 }
diffservMapEntry OBJECT-TYPE
SYNTAX DiffservMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in diffservMapTable."
INDEX { diffservMapDscp }
::= { diffservMapTable 1 }
DiffservMapEntry ::=
SEQUENCE {
diffservMapDscp INTEGER,
diffservMapPriority INTEGER
}
diffservMapDscp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"0-63"
::= { diffservMapEntry 1 }
diffservMapPriority OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"0-7"
::= { diffservMapEntry 2 }
-- diffservPortTable
diffservPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF DiffservPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { diffservSetup 3 }
diffservPortEntry OBJECT-TYPE
SYNTAX DiffservPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in diffservPortTable."
INDEX { dot1dBasePort }
::= { diffservPortTable 1 }
DiffservPortEntry ::=
SEQUENCE {
diffservPortState EnabledStatus
}
diffservPortState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { diffservPortEntry 1 }
-- clusterSetup
clusterSetup OBJECT IDENTIFIER ::= { es2108g 22 }
-- clusterManager
clusterManager OBJECT IDENTIFIER ::= { clusterSetup 1 }
clusterMaxNumOfManager OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterManager 1 }
-- clusterManagerTable
clusterManagerTable OBJECT-TYPE
SYNTAX SEQUENCE OF ClusterManagerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { clusterManager 2 }
clusterManagerEntry OBJECT-TYPE
SYNTAX ClusterManagerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in clusterManagerTable."
INDEX { clusterManagerVid }
::= { clusterManagerTable 1 }
ClusterManagerEntry ::=
SEQUENCE {
clusterManagerVid INTEGER,
clusterManagerName DisplayString,
clusterManagerRowStatus RowStatus
}
clusterManagerVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterManagerEntry 1 }
clusterManagerName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { clusterManagerEntry 2 }
clusterManagerRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { clusterManagerEntry 3 }
-- clusterMembers
clusterMembers OBJECT IDENTIFIER ::= { clusterSetup 2 }
clusterMaxNumOfMember OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterMembers 1 }
-- clusterMemberTable
clusterMemberTable OBJECT-TYPE
SYNTAX SEQUENCE OF ClusterMemberEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { clusterMembers 2 }
clusterMemberEntry OBJECT-TYPE
SYNTAX ClusterMemberEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in clusterMemberTable."
INDEX { clusterMemberMac }
::= { clusterMemberTable 1 }
ClusterMemberEntry ::=
SEQUENCE {
clusterMemberMac MacAddress,
clusterMemberName DisplayString,
clusterMemberModel DisplayString,
clusterMemberPassword DisplayString,
clusterMemberRowStatus RowStatus
}
clusterMemberMac OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterMemberEntry 1 }
clusterMemberName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterMemberEntry 2 }
clusterMemberModel OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterMemberEntry 3 }
clusterMemberPassword OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { clusterMemberEntry 4 }
clusterMemberRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { clusterMemberEntry 5 }
-- clusterCandidates
clusterCandidates OBJECT IDENTIFIER ::= { clusterSetup 3 }
-- clusterCandidateTable
clusterCandidateTable OBJECT-TYPE
SYNTAX SEQUENCE OF ClusterCandidateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { clusterCandidates 1 }
clusterCandidateEntry OBJECT-TYPE
SYNTAX ClusterCandidateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in clusterCandidateTable."
INDEX { clusterCandidateMac }
::= { clusterCandidateTable 1 }
ClusterCandidateEntry ::=
SEQUENCE {
clusterCandidateMac MacAddress,
clusterCandidateName DisplayString,
clusterCandidateModel DisplayString
}
clusterCandidateMac OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterCandidateEntry 1 }
clusterCandidateName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterCandidateEntry 2 }
clusterCandidateModel OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterCandidateEntry 3 }
-- clusterStatus
clusterStatus OBJECT IDENTIFIER ::= { clusterSetup 4 }
clusterStatusRole OBJECT-TYPE
SYNTAX INTEGER {
none(0),
manager(1),
member(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterStatus 1 }
clusterStatusManager OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterStatus 2 }
clsuterStatusMaxNumOfMember OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterStatus 3 }
-- clusterStatusMemberTable
clusterStatusMemberTable OBJECT-TYPE
SYNTAX SEQUENCE OF ClusterStatusMemberEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { clusterStatus 4 }
clusterStatusMemberEntry OBJECT-TYPE
SYNTAX ClusterStatusMemberEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in clusterStatusMemberTable."
INDEX { clusterStatusMemberMac }
::= { clusterStatusMemberTable 1 }
ClusterStatusMemberEntry ::=
SEQUENCE {
clusterStatusMemberMac MacAddress,
clusterStatusMemberName DisplayString,
clusterStatusMemberModel DisplayString,
clusterStatusMemberStatus INTEGER
}
clusterStatusMemberMac OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterStatusMemberEntry 1 }
clusterStatusMemberName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterStatusMemberEntry 2 }
clusterStatusMemberModel OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterStatusMemberEntry 3 }
clusterStatusMemberStatus OBJECT-TYPE
SYNTAX INTEGER {
error(0),
online(1),
offline(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterStatusMemberEntry 4 }
--fault MIB
faultMIB MODULE-IDENTITY
LAST-UPDATED "200411031200Z" -- YYYY/MM/DD, HH/MM
ORGANIZATION "ZyXEL"
CONTACT-INFO ""
DESCRIPTION
"Fault event table definitions"
::= { es2108g 26 }
-- **************************************************************************
-- Local Textual Conventions
-- **************************************************************************
UtcTimeStamp ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Universal Time Coordinated as a 32-bit value that designates
the number of seconds since Jan 1, 1970 12:00AM."
SYNTAX Unsigned32
EventIdNumber ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This textual convention describes the index that uniquely
identifies a fault event type in the entire system. Every fault
event type, e.g. link down, has a unique EventIdNumber."
SYNTAX Integer32
EventSeverity ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This textual convention describes the severity of a fault event.
The decreasing order of severity is shown in the textual
convention."
SYNTAX INTEGER{
critical (1),
major (2),
minor (3),
informational (4)
}
EventServiceAffective ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This textual convention indicates whether an event is immediately
service affecting or not."
SYNTAX INTEGER{
noServiceAffected (1),
serviceAffected (2)
}
InstanceType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This textual convention describes the type of an instanceId
associated with each event and by that means specifies how
the instanceId variable should be intepreted.
Various instanceId types are specified below to enable fault
monitoring for different kind of devices from fixed
configuration pizza boxes to multi chassis nodes. All
instanceId types may not need to be used in every device
type.
Note also that instanceId semantics are element type dependent
(e.g. different kind of interface naming conventions may be used)
and thus instanceId usage may vary from element to element.
=========================================================================
Type Description Example form
of InstanceId
=========================================================================
unknown (1) unknown type - Irrelevant-
-------------------------------------------------------------------------
node (2) Associated with events originating from 1
the node. Used for general events that (Node number)
can not be associated with any specific
block. InstanceId value 1 is used for
single node equipment.
-------------------------------------------------------------------------
shelf (3) Associated with events originating from 1
the shelf. In the case of fixed (shelf number)
configuration devices this type is used
for events that are associated with the
physical enclosure, e.g. faults related
to fan etc. InstanceId value 1 is used
for single self equipment.
-------------------------------------------------------------------------
line (4) Associated with events originating from
physical interfaces or associated
components such as line cards.
InstanceId usage examples for faults
originating from:
- Physical port: Simply port number, e.g. .......1
-------------------------------------------------------------------------
switch (5) Associated with events originating from 1
from a switch chip or a switch card. (switch number)
For single switch equipment InstanceId
value 1 is used, for multi swich nodes
InstanceId semantics if for further
study.
-------------------------------------------------------------------------
lsp (6) Associated with events originating from 1
a particular lsp. (lsp index)
NOTE: In this case the InstanceName
contains the lsp name and InstanceId
contains lsp index.
-------------------------------------------------------------------------
l2Interface(7) Associated with events originating from - TBD -
a particular layer 2 interface. Used for
layer 2 related events such as L2 control
protocol faults. InstanceId semantics is
for further study.
-------------------------------------------------------------------------
l3Interface(8) Associated with events originating from - TBD -
a particular layer 3 interface. Used for
layer 3 related events such as L3 control
protocol faults. InstanceId semantics is
for further study.
-------------------------------------------------------------------------
rowIndex (9) Associated with events reporting about a
'logical' or conceptual table that consists
of rows. The Instance Id is the index/key
for a row in the table. The format of the
Instance Id will simply be a series of decimal
numbers seperated by a '.':
========================================================================="
SYNTAX INTEGER {
unknown (1),
node (2),
shelf (3),
line (4),
switch (5),
lsp (6),
l2Interface(7),
l3Interface(8),
rowIndex(9)
}
-- *****************************************************************************
-- Top level structure of this MIB.
-- *****************************************************************************
eventObjects OBJECT IDENTIFIER ::= { faultMIB 1 }
-- *****************************************************************************
-- Event Table
--
-- Event table reports all currently active fault events. Only normal type of
-- faults (i.e. faults that are not automatically and immediately cleared) are
-- present in the event table. Delta faults (i.e. faults that are automatically
-- cleared) are reported only by using trap messages.
-- *****************************************************************************
eventTable OBJECT-TYPE
SYNTAX SEQUENCE OF EventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of currently active fault events. All faults
of normal type regardless of their severity level
are recorded in the event table. When a normal
type fault is cleared it is deleted from the event
table."
::= { eventObjects 1 }
eventEntry OBJECT-TYPE
SYNTAX EventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing information about an
event in the event table."
INDEX { eventSeqNum }
::= { eventTable 1 }
EventEntry ::=
SEQUENCE {
eventSeqNum Integer32,
eventEventId EventIdNumber,
eventName DisplayString,
eventInstanceType InstanceType,
eventInstanceId DisplayString,
eventInstanceName DisplayString,
eventSeverity EventSeverity,
eventSetTime UtcTimeStamp,
eventDescription DisplayString,
eventServAffective EventServiceAffective
}
eventSeqNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable represents the sequence number of an event.
Sequence number is incremented monotonically starting
from 0 until it reaches its maximum and wraps around back
to 0.
Sequence number is incremented when
- the state of a normal type fault is set on (the same sequence
number is present in the events table as well as in the trap
that is sent to notify about the fault on event)
- delta event occurs (sequence number present in trap message)
- the state of a normal type fault is set off (sequence number
present in trap that is sent to notify for clearing)."
::= { eventEntry 1 }
eventEventId OBJECT-TYPE
SYNTAX EventIdNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable represents the event ID which uniquely
identifies the event in the entire system."
::= { eventEntry 2 }
eventName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..40))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable represents the name of the event, for
example 'Ethernet Link Down'"
::= { eventEntry 3 }
eventInstanceType OBJECT-TYPE
SYNTAX InstanceType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable represents the type of InstanceId of a
particular event in the event table. In brief
the instanceType refers to the type of sub-component
generating this event in the system, for example
switch (5). For more details see the textual
conventions section.
AFFECTS: eventInstanceId,
eventInstanceName"
::= { eventEntry 4 }
eventInstanceId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable represents the InstanceId of a particular
event in the event current table. In brief the instanceId
refers to the sub-component generating this event in the
system, for example '1' for port 1. For more details see
the textual conventions section.
DEPENDS ON: eventInstanceType"
::= { eventEntry 5 }
eventInstanceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable is mainly used to store additional information
about the sub-component that is generating an event. For
example this field may specify what cooling fan is faulty.
DEPENDS ON: eventInstanceType"
::= { eventEntry 6 }
eventSeverity OBJECT-TYPE
SYNTAX EventSeverity
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable dictates the urgency of action when a event
occurs. There are four severity levels - Critical, Major,
Minor, and Informational. Critical events are those, which
require immediate operator intervention to prevent/reduce
system down time. Major events require quick attention and
Minor events possibly require some attention. Informational
events indicate the occurrence of events that may need to be
investigated."
::= { eventEntry 7 }
eventSetTime OBJECT-TYPE
SYNTAX UtcTimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This table contains only normal events and this variable
represents the time when the event become active, i.e. the
number of seconds since Jan 1, 1970 12:00AM."
::= { eventEntry 8 }
eventDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable contains a description of the event and reasons
behind the event. This is a free format alpha-numeric string
that is set by the entity generating this event. This variable
may be empty if there is no usefull information to report.
The maximum length of this string is 255 characters."
::= { eventEntry 9 }
eventServAffective OBJECT-TYPE
SYNTAX EventServiceAffective
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates whether the event is service affective or not"
::= { eventEntry 10 }
-- fault Trap MIB
faultTrapsMIB MODULE-IDENTITY
LAST-UPDATED "200411011200Z" -- YYYY/MM/DD, HH/MM
ORGANIZATION "ZyXEL"
CONTACT-INFO ""
DESCRIPTION
"Fault event trap definitions"
::= { es2108g 27 }
trapInfoObjects OBJECT IDENTIFIER ::= { faultTrapsMIB 1}
trapNotifications OBJECT IDENTIFIER ::= { faultTrapsMIB 2}
-- **************************************************************************
-- Local Textual Conventions
-- **************************************************************************
EventPersistence ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This textual convention indicates whether the event is delta
(automatically and immediately cleared) or normal (not
automatically cleared)."
SYNTAX INTEGER{
normal (1),
delta (2)
}
-- **************************************************************************
-- Trap information object definitions
-- **************************************************************************
trapRefSeqNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the former sequence number of a cleared event
in the event table. Not intended to read but only used in
trap notifications."
::= { trapInfoObjects 1 }
trapPersistence OBJECT-TYPE
SYNTAX EventPersistence
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the event is delta (automatically and
immediately cleared) or normal (not automatically cleared).
Not intended to read but only used in trap notifications."
::= { trapInfoObjects 2 }
trapSenderNodeId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Represents the node ID of the sending network element. If not
supported should be set to 0. Not intended to read but only
used in trap notifications."
::= { trapInfoObjects 3 }
-- ***************************************************************************
-- Trap definitions
-- ***************************************************************************
eventOnTrap NOTIFICATION-TYPE
OBJECTS {
eventSeqNum,
eventEventId,
eventName,
eventSetTime,
eventSeverity,
eventInstanceType,
eventInstanceId,
eventInstanceName,
eventServAffective,
eventDescription,
trapPersistence,
trapSenderNodeId,
sysObjectID}
STATUS current
DESCRIPTION
"This trap is used to inform network management system that a delta
fault event (events that are automatically cleared) has occured
or a normal fault event (not automatically cleared) state has
been set on.
Objects are used as follows:
- eventSeqNum is the sequence number of the event. For normal
type of events must equal to the sequence number of the event
in the events table.
- eventEventId specifies what fault event has occured.
- eventName specifies the name of the fault event.
- eventSetTime indicates when fault event has occured
(delta events) or when fault has been set on (normal events).
- eventSeverity reports the severity level of the event.
- eventInstanceType indicates what kind of object is faulty.
- eventInstanceId specifies what instance is faulty.
- eventInstanceName may contain textual description for
the faulty object.
- eventServAffective specifies whether the event is
immediately service affcetive.
- eventDescription reports possible additional information about the event.
- trapPersistence tells whether this event is a delta or normal event.
- trapSenderNodeId specifies the node ID of the sending network element if
configuring it is supported for the network element, otherwise 0.
- sysObjectID specifies what kind of equipment reports the fault event.
For more information see the eventTable specification"
::= { trapNotifications 1 }
eventClearedTrap NOTIFICATION-TYPE
OBJECTS {
eventSeqNum,
eventEventId,
eventSetTime,
eventInstanceType,
eventInstanceId,
trapRefSeqNum,
trapSenderNodeId,
sysObjectID}
STATUS current
DESCRIPTION
"This trap is used to inform network management system that a normal
type fault event has been cleared (state set off).
Objects are used as follows:
- eventSeqNum is the sequence number of the this clearing event. Note that
the sequence number of the cleared event is reported in the trapRefSeqNum
object.
- eventEventId specifies what event has been cleared.
- eventSetTime indicates when fault event has been cleared.
- eventInstanceType indicates what kind of object has been
faulty.
- eventInstanceId specifies what instance has been faulty.
- trapRefSeqNum specifies the sequence number of the cleared event (i.e.
the sequence number was assigned for the event in the events table).
- trapSenderNodeId specifies the node ID of the sending network element if
configuring it is supported for the network element, otherwise 0.
- sysObjectID specifies what kind of equipment reports the clearing event.
For more information see the eventTable specification"
::= { trapNotifications 2 }
-- multicastPortSetup
multicastPortSetup OBJECT IDENTIFIER ::= { es2108g 28 }
multicastPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF MulticastPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { multicastPortSetup 1 }
multicastPortEntry OBJECT-TYPE
SYNTAX MulticastPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in multicastPortTable."
INDEX { dot1dBasePort }
::= { multicastPortTable 1 }
MulticastPortEntry ::=
SEQUENCE {
multicastPortImmediateLeave EnabledStatus,
multicastPortMaxGroupLimited EnabledStatus,
multicastPortMaxOfGroup INTEGER,
multicastPortIgmpFilteringProfile DisplayString,
multicastPortQueryMode INTEGER
}
multicastPortImmediateLeave OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { multicastPortEntry 1 }
multicastPortMaxGroupLimited OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { multicastPortEntry 2 }
multicastPortMaxOfGroup OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"0..255"
::= { multicastPortEntry 3 }
multicastPortIgmpFilteringProfile OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { multicastPortEntry 4 }
multicastPortQueryMode OBJECT-TYPE
SYNTAX INTEGER {
auto_mode(1),
fix_mode(2),
edge_mode(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specify query mode for each port"
::= { multicastPortEntry 5 }
-- multicastStatus
multicastStatus OBJECT IDENTIFIER ::= { es2108g 29 }
multicastStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF MulticastStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { multicastStatus 1 }
multicastStatusEntry OBJECT-TYPE
SYNTAX MulticastStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in multicastStatusTable."
INDEX { multicastStatusVlanID, multicastStatusPort, multicastStatusGroup }
::= { multicastStatusTable 1 }
MulticastStatusEntry ::=
SEQUENCE {
multicastStatusIndex INTEGER,
multicastStatusVlanID INTEGER,
multicastStatusPort INTEGER,
multicastStatusGroup IpAddress
}
multicastStatusIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { multicastStatusEntry 1 }
multicastStatusVlanID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { multicastStatusEntry 2 }
multicastStatusPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { multicastStatusEntry 3 }
multicastStatusGroup OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { multicastStatusEntry 4 }
-- test igmpcount
igmpCountTable OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpCountEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A count table of igmp query/report/leave message."
::= { multicastStatus 2 }
igmpCountEntry OBJECT-TYPE
SYNTAX IgmpCountEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in igmpCountTable."
INDEX { igmpCountIndex }
::= { igmpCountTable 1 }
IgmpCountEntry ::=
SEQUENCE {
igmpCountIndex INTEGER,
igmpCountInQuery INTEGER,
igmpCountInReport INTEGER,
igmpCountInLeave INTEGER,
igmpCountInQueryDrop INTEGER,
igmpCountInReportDrop INTEGER,
igmpCountInLeaveDrop INTEGER,
igmpCountOutQuery INTEGER,
igmpCountOutReport INTEGER,
igmpCountOutLeave INTEGER
}
igmpCountIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Index of IgmpCountEntry. 0 means total count in whole system"
::= { igmpCountEntry 1 }
igmpCountInQuery OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpCountEntry 2 }
igmpCountInReport OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpCountEntry 3 }
igmpCountInLeave OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpCountEntry 4 }
igmpCountInQueryDrop OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpCountEntry 5 }
igmpCountInReportDrop OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpCountEntry 6 }
igmpCountInLeaveDrop OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpCountEntry 7 }
igmpCountOutQuery OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpCountEntry 8 }
igmpCountOutReport OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpCountEntry 9 }
igmpCountOutLeave OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpCountEntry 10 }
-- multicastVlanStatusTable
multicastVlanStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF MulticastVlanStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { multicastStatus 3 }
multicastVlanStatusEntry OBJECT-TYPE
SYNTAX MulticastVlanStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in multicastVlanStatusTable."
INDEX { multicastVlanStatusVlanID }
::= { multicastVlanStatusTable 1 }
MulticastVlanStatusEntry ::=
SEQUENCE {
multicastVlanStatusVlanID INTEGER,
multicastVlanStatusType INTEGER,
multicastVlanQueryPort PortList
}
multicastVlanStatusVlanID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { multicastVlanStatusEntry 1 }
multicastVlanStatusType OBJECT-TYPE
SYNTAX INTEGER {
dynamic(1),
mvr (2),
static(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { multicastVlanStatusEntry 2 }
multicastVlanQueryPort OBJECT-TYPE
SYNTAX PortList
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { multicastVlanStatusEntry 3 }
-- igmpFilteringProfileSetup
igmpFilteringProfileSetup OBJECT IDENTIFIER ::= { es2108g 30 }
igmpFilteringMaxNumberOfProfile OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpFilteringProfileSetup 1 }
igmpFilteringProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpFilteringProfileEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { igmpFilteringProfileSetup 2 }
igmpFilteringProfileEntry OBJECT-TYPE
SYNTAX IgmpFilteringProfileEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in igmpFilteringProfileTable."
INDEX { igmpFilteringProfileName, igmpFilteringProfileStartAddress, igmpFilteringProfileEndAddress }
::= { igmpFilteringProfileTable 1 }
IgmpFilteringProfileEntry ::=
SEQUENCE {
igmpFilteringProfileName DisplayString,
igmpFilteringProfileStartAddress IpAddress,
igmpFilteringProfileEndAddress IpAddress,
igmpFilteringProfileRowStatus RowStatus
}
igmpFilteringProfileName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpFilteringProfileEntry 1 }
igmpFilteringProfileStartAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpFilteringProfileEntry 2 }
igmpFilteringProfileEndAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { igmpFilteringProfileEntry 3 }
igmpFilteringProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { igmpFilteringProfileEntry 4 }
-- MVRSetup
mvrSetup OBJECT IDENTIFIER ::= { es2108g 31 }
maxNumberOfMVR OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { mvrSetup 1 }
mvrTable OBJECT-TYPE
SYNTAX SEQUENCE OF MvrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { mvrSetup 2 }
mvrEntry OBJECT-TYPE
SYNTAX MvrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in mvrTable."
INDEX { mvrVlanID }
::= { mvrTable 1 }
MvrEntry ::=
SEQUENCE {
mvrVlanID INTEGER,
mvrName DisplayString,
mvrMode INTEGER,
mvrRowStatus RowStatus,
mvr8021pPriority INTEGER
}
mvrVlanID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"1..4094"
::= { mvrEntry 1 }
mvrName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mvrEntry 2 }
mvrMode OBJECT-TYPE
SYNTAX INTEGER {
dynamic(0),
compatible(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mvrEntry 3 }
mvrRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { mvrEntry 4 }
mvr8021pPriority OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set the 802.1p priority of control messages within MVR (0~7)"
::= { mvrEntry 5 }
mvrPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF MvrPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { mvrSetup 3 }
mvrPortEntry OBJECT-TYPE
SYNTAX MvrPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in mvrPortTable."
INDEX { mvrVlanID, dot1dBasePort }
::= { mvrPortTable 1 }
MvrPortEntry ::=
SEQUENCE {
mvrPortRole INTEGER,
mvrPortTagging EnabledStatus
}
mvrPortRole OBJECT-TYPE
SYNTAX INTEGER {
none(1),
source_port(2),
receiver_port(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mvrPortEntry 1 }
mvrPortTagging OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mvrPortEntry 2 }
maxNumberOfMvrGroup OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { mvrSetup 4 }
mvrGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF MvrGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { mvrSetup 5 }
mvrGroupEntry OBJECT-TYPE
SYNTAX MvrGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in mvrGroupTable."
INDEX { mvrVlanID, mvrGroupName }
::= { mvrGroupTable 1 }
MvrGroupEntry ::=
SEQUENCE {
mvrGroupName DisplayString,
mvrGroupStartAddress IpAddress,
mvrGroupEndAddress IpAddress,
mvrGroupRowStatus RowStatus
}
mvrGroupName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { mvrGroupEntry 1 }
mvrGroupStartAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mvrGroupEntry 2 }
mvrGroupEndAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mvrGroupEntry 3 }
mvrGroupRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { mvrGroupEntry 4 }
-- sysLogSetup
sysLogSetup OBJECT IDENTIFIER ::= { es2108g 32 }
sysLogState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"sysLog enabled/disabled for the switch."
::= { sysLogSetup 1 }
-- sysLogTypeTable
sysLogTypeTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysLogTypeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { sysLogSetup 2 }
sysLogTypeEntry OBJECT-TYPE
SYNTAX SysLogTypeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in sysLogTypeTable."
INDEX { sysLogTypeIndex }
::= { sysLogTypeTable 1 }
SysLogTypeEntry ::=
SEQUENCE {
sysLogTypeIndex INTEGER,
sysLogTypeName DisplayString,
sysLogTypeState EnabledStatus,
sysLogTypeFacility INTEGER
}
sysLogTypeIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { sysLogTypeEntry 1 }
sysLogTypeName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { sysLogTypeEntry 2 }
sysLogTypeState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { sysLogTypeEntry 3 }
sysLogTypeFacility OBJECT-TYPE
SYNTAX INTEGER {
local_user0(0),
local_user1(1),
local_user2(2),
local_user3(3),
local_user4(4),
local_user5(5),
local_user6(6),
local_user7(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { sysLogTypeEntry 4 }
-- sysLogServerTable
sysLogServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysLogServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { sysLogSetup 3 }
sysLogServerEntry OBJECT-TYPE
SYNTAX SysLogServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in sysLogServerTable."
INDEX { sysLogServerAddress }
::= { sysLogServerTable 1 }
SysLogServerEntry ::=
SEQUENCE {
sysLogServerAddress IpAddress,
sysLogServerLogLevel INTEGER,
sysLogServerRowStatus RowStatus
}
sysLogServerAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { sysLogServerEntry 1 }
sysLogServerLogLevel OBJECT-TYPE
SYNTAX INTEGER {
level0(0),
level0-1(1),
level0-2(2),
level0-3(3),
level0-4(4),
level0-5(5),
level0-6(6),
level0-7(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { sysLogServerEntry 2 }
sysLogServerRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { sysLogServerEntry 3 }
-- dhcpSetup
dhcpSetup OBJECT IDENTIFIER ::= { es2108g 33 }
globalDhcpRelay OBJECT IDENTIFIER ::= { dhcpSetup 1 }
globalDhcpRelayEnable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { globalDhcpRelay 1 }
globalDhcpRelayOption82Enable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { globalDhcpRelay 2 }
globalDhcpRelayInfoEnable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { globalDhcpRelay 3 }
globalDhcpRelayInfoData OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { globalDhcpRelay 4 }
-- globalDhcpRelayRemoteServer
maxNumberOfGlobalDhcpRelayRemoteServer OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { globalDhcpRelay 5 }
-- globalDhcpRelayRemoteServerTable
globalDhcpRelayRemoteServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF GlobalDhcpRelayRemoteServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { globalDhcpRelay 6 }
globalDhcpRelayRemoteServerEntry OBJECT-TYPE
SYNTAX GlobalDhcpRelayRemoteServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in globalDhcpRelayRemoteServerTable."
INDEX { globalDhcpRelayRemoteServerIp }
::= { globalDhcpRelayRemoteServerTable 1 }
GlobalDhcpRelayRemoteServerEntry ::=
SEQUENCE {
globalDhcpRelayRemoteServerIp IpAddress,
globalDhcpRelayRemoteServerRowStatus RowStatus
}
globalDhcpRelayRemoteServerIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { globalDhcpRelayRemoteServerEntry 1 }
globalDhcpRelayRemoteServerRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { globalDhcpRelayRemoteServerEntry 2 }
--
dhcpRelay OBJECT IDENTIFIER ::= { dhcpSetup 3 }
dhcpRelayInfoData OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpRelay 1 }
maxNumberOfDhcpRelay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of DHCP relay entries that can be created.
A value of 0 for this object implies that there exists settings for
global DHCP relay."
::= { dhcpRelay 2 }
maxNumberOfDhcpRelayRemoteServer OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpRelay 3 }
-- dhcpRelayRemoteServerTable
dhcpRelayRemoteServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpRelayRemoteServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { dhcpRelay 4 }
dhcpRelayRemoteServerEntry OBJECT-TYPE
SYNTAX DhcpRelayRemoteServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in dhcpRelayRemoteServerTable."
INDEX { dhcpRelayVid, dhcpRelayRemoteServerIp }
::= { dhcpRelayRemoteServerTable 1 }
DhcpRelayRemoteServerEntry ::=
SEQUENCE {
dhcpRelayVid INTEGER,
dhcpRelayRemoteServerIp IpAddress,
dhcpRelayRemoteServerRowStatus RowStatus
}
dhcpRelayVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpRelayRemoteServerEntry 1 }
dhcpRelayRemoteServerIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { dhcpRelayRemoteServerEntry 2 }
dhcpRelayRemoteServerRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { dhcpRelayRemoteServerEntry 3 }
-- dhcpRelayTable
dhcpRelayTable OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpRelayEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { dhcpRelay 5 }
dhcpRelayEntry OBJECT-TYPE
SYNTAX DhcpRelayEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in dhcpRelayTable."
INDEX { dhcpRelayVid }
::= { dhcpRelayTable 1 }
DhcpRelayEntry ::=
SEQUENCE {
dhcpRelayOption82Enable EnabledStatus,
dhcpRelayInfoEnable EnabledStatus
}
dhcpRelayOption82Enable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { dhcpRelayEntry 1 }
dhcpRelayInfoEnable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { dhcpRelayEntry 2 }
-- radiusServerSetup
radiusServerSetup OBJECT IDENTIFIER ::= { es2108g 34 }
radiusAuthServerSetup OBJECT IDENTIFIER ::= { radiusServerSetup 1 }
radiusAuthServerMode OBJECT-TYPE
SYNTAX INTEGER{
index-priority(1),
round-robin(2),
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { radiusAuthServerSetup 1 }
radiusAuthServerTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { radiusAuthServerSetup 2 }
-- radiusAuthServerTable
radiusAuthServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadiusAuthServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { radiusAuthServerSetup 3 }
radiusAuthServerEntry OBJECT-TYPE
SYNTAX RadiusAuthServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in radiusAuthServerTable."
INDEX { radiusAuthServerIndex }
::= { radiusAuthServerTable 1 }
RadiusAuthServerEntry ::=
SEQUENCE {
radiusAuthServerIndex INTEGER,
radiusAuthServerIpAddr IpAddress,
radiusAuthServerUdpPort INTEGER,
radiusAuthServerSharedSecret DisplayString
}
radiusAuthServerIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { radiusAuthServerEntry 1 }
radiusAuthServerIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { radiusAuthServerEntry 2 }
radiusAuthServerUdpPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { radiusAuthServerEntry 3 }
radiusAuthServerSharedSecret OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { radiusAuthServerEntry 4 }
radiusAcctServerSetup OBJECT IDENTIFIER ::= { radiusServerSetup 2 }
radiusAcctServerTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { radiusAcctServerSetup 1 }
-- radiusAcctServerTable
radiusAcctServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadiusAcctServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { radiusAcctServerSetup 2 }
radiusAcctServerEntry OBJECT-TYPE
SYNTAX RadiusAcctServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in radiusAcctServerTable."
INDEX { radiusAcctServerIndex }
::= { radiusAcctServerTable 1 }
RadiusAcctServerEntry ::=
SEQUENCE {
radiusAcctServerIndex INTEGER,
radiusAcctServerIpAddr IpAddress,
radiusAcctServerUdpPort INTEGER,
radiusAcctServerSharedSecret DisplayString
}
radiusAcctServerIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { radiusAcctServerEntry 1 }
radiusAcctServerIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { radiusAcctServerEntry 2 }
radiusAcctServerUdpPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { radiusAcctServerEntry 3 }
radiusAcctServerSharedSecret OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { radiusAcctServerEntry 4 }
-- tacacsServerSetup
tacacsServerSetup OBJECT IDENTIFIER ::= { es2108g 35 }
tacacsAuthServerSetup OBJECT IDENTIFIER ::= { tacacsServerSetup 1 }
tacacsAuthServerMode OBJECT-TYPE
SYNTAX INTEGER{
index-priority(1),
round-robin(2),
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { tacacsAuthServerSetup 1 }
tacacsAuthServerTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { tacacsAuthServerSetup 2 }
-- tacacsAuthServerTable
tacacsAuthServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF TacacsAuthServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { tacacsAuthServerSetup 3 }
tacacsAuthServerEntry OBJECT-TYPE
SYNTAX TacacsAuthServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in tacacsAuthServerTable."
INDEX { tacacsAuthServerIndex }
::= { tacacsAuthServerTable 1 }
TacacsAuthServerEntry ::=
SEQUENCE {
tacacsAuthServerIndex INTEGER,
tacacsAuthServerIpAddr IpAddress,
tacacsAuthServerTcpPort INTEGER,
tacacsAuthServerSharedSecret DisplayString
}
tacacsAuthServerIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { tacacsAuthServerEntry 1 }
tacacsAuthServerIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { tacacsAuthServerEntry 2 }
tacacsAuthServerTcpPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { tacacsAuthServerEntry 3 }
tacacsAuthServerSharedSecret OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { tacacsAuthServerEntry 4 }
tacacsAcctServerSetup OBJECT IDENTIFIER ::= { tacacsServerSetup 2 }
tacacsAcctServerTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { tacacsAcctServerSetup 1 }
-- tacacsAcctServerTable
tacacsAcctServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF TacacsAcctServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { tacacsAcctServerSetup 2 }
tacacsAcctServerEntry OBJECT-TYPE
SYNTAX TacacsAcctServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in tacacsAcctServerTable."
INDEX { tacacsAcctServerIndex }
::= { tacacsAcctServerTable 1 }
TacacsAcctServerEntry ::=
SEQUENCE {
tacacsAcctServerIndex INTEGER,
tacacsAcctServerIpAddr IpAddress,
tacacsAcctServerTcpPort INTEGER,
tacacsAcctServerSharedSecret DisplayString
}
tacacsAcctServerIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { tacacsAcctServerEntry 1 }
tacacsAcctServerIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { tacacsAcctServerEntry 2 }
tacacsAcctServerTcpPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { tacacsAcctServerEntry 3 }
tacacsAcctServerSharedSecret OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { tacacsAcctServerEntry 4 }
-- aaaSetup
aaaSetup OBJECT IDENTIFIER ::= { es2108g 36 }
authenticationSetup OBJECT IDENTIFIER ::= { aaaSetup 1 }
-- authenticationTypeTable
authenticationTypeTable OBJECT-TYPE
SYNTAX SEQUENCE OF AuthenticationTypeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { authenticationSetup 1 }
authenticationTypeEntry OBJECT-TYPE
SYNTAX AuthenticationTypeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in authenticationTypeTable."
INDEX { authenticationTypeName }
::= { authenticationTypeTable 1 }
AuthenticationTypeEntry ::=
SEQUENCE {
authenticationTypeName DisplayString,
authenticationTypeMethodList OCTET STRING
}
authenticationTypeName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { authenticationTypeEntry 1 }
authenticationTypeMethodList OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { authenticationTypeEntry 2 }
accountingSetup OBJECT IDENTIFIER ::= { aaaSetup 2 }
accountingUpdatePeriod OBJECT-TYPE
SYNTAX Integer32
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { accountingSetup 1 }
-- accountingTypeTable
accountingTypeTable OBJECT-TYPE
SYNTAX SEQUENCE OF AccountingTypeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { accountingSetup 2 }
accountingTypeEntry OBJECT-TYPE
SYNTAX AccountingTypeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in accountingTypeTable."
INDEX { accountingTypeName }
::= { accountingTypeTable 1 }
AccountingTypeEntry ::=
SEQUENCE {
accountingTypeName DisplayString,
accountingTypeActive EnabledStatus,
accountingTypeBroadcast EnabledStatus,
accountingTypeMode INTEGER,
accountingTypeMethod INTEGER,
accountingTypePrivilege INTEGER
}
accountingTypeName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { accountingTypeEntry 1 }
accountingTypeActive OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { accountingTypeEntry 2 }
accountingTypeBroadcast OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { accountingTypeEntry 3 }
accountingTypeMode OBJECT-TYPE
SYNTAX INTEGER{
not-available(255),
start-stop(1),
stop-only(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { accountingTypeEntry 4 }
accountingTypeMethod OBJECT-TYPE
SYNTAX INTEGER{
radius(1),
tacacs(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { accountingTypeEntry 5 }
accountingTypePrivilege OBJECT-TYPE
SYNTAX INTEGER{
not-available(255),
privilege-0(0),
privilege-1(1),
privilege-2(2),
privilege-3(3),
privilege-4(4),
privilege-5(5),
privilege-6(6),
privilege-7(7),
privilege-8(8),
privilege-9(9),
privilege-10(10),
privilege-11(11),
privilege-12(12),
privilege-13(13),
privilege-14(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { accountingTypeEntry 6 }
---------------------------------------------------
--
-- ip source guard
--
---------------------------------------------------
ipsg OBJECT IDENTIFIER ::= { es2108g 101 }
ipsgTable OBJECT-TYPE
SYNTAX SEQUENCE OF IpsgEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { ipsg 1 }
ipsgEntry OBJECT-TYPE
SYNTAX IpsgEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
INDEX { ipsgEntryMac, ipsgEntryVid }
::= { ipsgTable 1 }
IpsgEntry ::=
SEQUENCE {
ipsgEntryMac MacAddress,
ipsgEntryVid INTEGER,
ipsgEntryIp IpAddress,
ipsgEntryLease INTEGER,
ipsgEntryType INTEGER,
ipsgEntryPort INTEGER,
ipsgEntryState RowStatus
}
ipsgEntryMac OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ipsgEntry 1 }
ipsgEntryVid OBJECT-TYPE
SYNTAX INTEGER (1.. 4094)
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ipsgEntry 2 }
ipsgEntryIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { ipsgEntry 3 }
ipsgEntryLease OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"second"
::= { ipsgEntry 4 }
ipsgEntryType OBJECT-TYPE
SYNTAX INTEGER { static(1), dhcp(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ipsgEntry 5 }
ipsgEntryPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"0 means any port"
::= { ipsgEntry 6 }
ipsgEntryState OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { ipsgEntry 7 }
---------------------------------------------------
--
-- arpInspect
--
---------------------------------------------------
arpInspect OBJECT IDENTIFIER ::= { es2108g 102 }
arpInspectSetup OBJECT IDENTIFIER ::= { arpInspect 1 }
arpInspectState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { arpInspectSetup 1 }
arpInspectFilterAgingTime OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { arpInspectSetup 2 }
arpInspectLog OBJECT IDENTIFIER ::= { arpInspectSetup 3 }
arpInspectLogEntries OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { arpInspectLog 1 }
arpInspectLogRate OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { arpInspectLog 2 }
arpInspectLogInterval OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { arpInspectLog 3 }
arpInspectVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF ArpInspectVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { arpInspectSetup 4 }
arpInspectVlanEntry OBJECT-TYPE
SYNTAX ArpInspectVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
INDEX { arpInspectVlanVid }
::= { arpInspectVlanTable 1 }
ArpInspectVlanEntry ::=
SEQUENCE {
arpInspectVlanVid INTEGER,
arpInspectVlanLog INTEGER,
arpInspectVlanStatus INTEGER
}
arpInspectVlanVid OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectVlanEntry 1 }
arpInspectVlanLog OBJECT-TYPE
SYNTAX INTEGER {
all (1),
none (2),
permit (3),
deny (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { arpInspectVlanEntry 2 }
arpInspectVlanStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { arpInspectVlanEntry 3 }
arpInspectPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF ArpInspectPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { arpInspectSetup 5 }
arpInspectPortEntry OBJECT-TYPE
SYNTAX ArpInspectPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
INDEX { arpInspectPortIndex }
::= { arpInspectPortTable 1 }
ArpInspectPortEntry ::=
SEQUENCE {
arpInspectPortIndex INTEGER,
arpInspectPortTrust INTEGER
}
arpInspectPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectPortEntry 1 }
arpInspectPortTrust OBJECT-TYPE
SYNTAX INTEGER {
trusted(1),
untrusted(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { arpInspectPortEntry 2 }
arpInspectStatus OBJECT IDENTIFIER ::= { arpInspect 2 }
arpInspectFilterClear OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { arpInspectStatus 1 }
arpInspectLogClear OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { arpInspectStatus 2 }
arpInspectFilterTable OBJECT-TYPE
SYNTAX SEQUENCE OF ArpInspectFilterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { arpInspectStatus 3 }
arpInspectFilterEntry OBJECT-TYPE
SYNTAX ArpInspectFilterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
INDEX { arpInspectFilterMac, arpInspectFilterVid }
::= { arpInspectFilterTable 1 }
ArpInspectFilterEntry ::=
SEQUENCE {
arpInspectFilterMac MacAddress,
arpInspectFilterVid INTEGER,
arpInspectFilterPort INTEGER,
arpInspectFilterExpiry INTEGER,
arpInspectFilterReason INTEGER,
arpInspectFilterRowStatus RowStatus
}
arpInspectFilterMac OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectFilterEntry 1 }
arpInspectFilterVid OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectFilterEntry 2 }
arpInspectFilterPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectFilterEntry 3 }
arpInspectFilterExpiry OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectFilterEntry 4 }
arpInspectFilterReason OBJECT-TYPE
SYNTAX INTEGER {
macVid(1),
port(2),
ip(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectFilterEntry 5 }
arpInspectFilterRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { arpInspectFilterEntry 6 }
arpInspectLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF ArpInspectLogEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { arpInspectStatus 4 }
arpInspectLogEntry OBJECT-TYPE
SYNTAX ArpInspectLogEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
INDEX { arpInspectLogMac, arpInspectLogVid, arpInspectLogPort, arpInspectLogIp }
::= { arpInspectLogTable 1 }
ArpInspectLogEntry ::=
SEQUENCE {
arpInspectLogMac MacAddress,
arpInspectLogVid INTEGER,
arpInspectLogPort INTEGER,
arpInspectLogIp IpAddress,
arpInspectLogNumPkt INTEGER,
arpInspectLogReason INTEGER,
arpInspectLogTime DateAndTime
}
arpInspectLogMac OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectLogEntry 1 }
arpInspectLogVid OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectLogEntry 2 }
arpInspectLogPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectLogEntry 3 }
arpInspectLogIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectLogEntry 4 }
arpInspectLogNumPkt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectLogEntry 5 }
arpInspectLogReason OBJECT-TYPE
SYNTAX INTEGER {
deny (1),
denyStatic (2),
denyDHCP (3),
permitStatic (4),
permitDHCP (5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectLogEntry 6 }
arpInspectLogTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpInspectLogEntry 7 }
---------------------------------------------------
--
-- loopGuardSetup
--
---------------------------------------------------
loopGuardSetup OBJECT IDENTIFIER ::= { es2108g 104 }
loopGuardState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { loopGuardSetup 1 }
-- loopGuardPortTable
loopGuardPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF LoopGuardPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { loopGuardSetup 2 }
loopGuardPortEntry OBJECT-TYPE
SYNTAX LoopGuardPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in loopGuardPortTable."
INDEX { dot1dBasePort }
::= { loopGuardPortTable 1 }
LoopGuardPortEntry ::=
SEQUENCE {
loopGuardPortState EnabledStatus
}
loopGuardPortState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { loopGuardPortEntry 1 }
-- MSTP
--****************************************************************
-- TEXTUAL-CONVENTIONs
--****************************************************************
MstiOrCistInstanceIndex ::= TEXTUAL-CONVENTION
STATUS mandatory
DESCRIPTION
"This textual convention is an extension of the
MstiInstanceIndex convention. This extension permits the
additional value of zero, which means Common and Internal
Spanning Tree (CIST)."
SYNTAX Integer32 (0..16)
mstp OBJECT IDENTIFIER ::= { es2108g 107 }
-- mstpGen group reflects configurations/statuses
-- the Bridge as a unit
mstpGen OBJECT IDENTIFIER ::= { mstp 1}
mstpGenState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enabled/disabled on the mrstp bridge."
::= { mstpGen 1 }
mstpGenCfgIdName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The configuration name that identifies the MST
region and is used as one of the inputs in the
computation of the MST Configuration Identifier."
REFERENCE
"12.12.3.4.2.b)"
::= { mstpGen 2 }
mstpGenCfgIdRevLevel OBJECT-TYPE
SYNTAX Integer32
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object identifies the MST revision that
identifies the MST region and is used as one
of the inputs in the computation of the MST
configuration Identifier."
REFERENCE
"12.12.3.4.2.c)"
::= { mstpGen 3 }
mstpGenCfgIdCfgDigest OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Configuration Digest."
REFERENCE
"12.12.3.3.3.a.4"
::= { mstpGen 4 }
mstpGenHelloTime OBJECT-TYPE
SYNTAX Timeout (100..1000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mstpGen 5 }
mstpGenMaxAge OBJECT-TYPE
SYNTAX Timeout (600..4000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mstpGen 6 }
mstpGenForwardDelay OBJECT-TYPE
SYNTAX Timeout (400..3000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= {mstpGen 7}
mstpGenMaxHops OBJECT-TYPE
SYNTAX Integer32 (4..30)
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"13.22.f)"
::= { mstpGen 8 }
mstpGenCistRootPathCost OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"."
::= { mstpGen 9 }
mstpGenCistRootBrid OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(32))
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"."
::= { mstpGen 10 }
-- MSTP MAP TABLE
mstMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF MstMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains one entry for each instance of MSTP."
::= { mstp 20 }
mstMapEntry OBJECT-TYPE
SYNTAX MstMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A conceptual row containing the status of the MSTP instance."
INDEX { mstMapIndex }
::= { mstMapTable 1 }
MstMapEntry ::= SEQUENCE {
mstMapIndex MstiOrCistInstanceIndex,
mstMapVlans1k OCTET STRING,
mstMapVlans2k OCTET STRING,
mstMapVlans3k OCTET STRING,
mstMapVlans4k OCTET STRING,
mstMapRowStatus RowStatus
}
mstMapIndex OBJECT-TYPE
SYNTAX MstiOrCistInstanceIndex
MAX-ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Uniquely identifies an instance. The entry of this table with index 0
presents always, represents CIST. When SET operation "
::= { mstMapEntry 1 }
mstMapVlans1k OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..128))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A string of octets containing one bit per VLAN. The
first octet corresponds to VLANs with VlanIndex values
1 through 8; the second octet to VLANs 9 through
16 etc. The most significant bit of each octet
corresponds to the lowest VlanIndex value in that octet.
For each VLAN that is mapped to this MSTP instance,
the bit corresponding to that VLAN is set to '1'.
Empty (zero) most significant octes are not mandatory."
::= { mstMapEntry 2 }
mstMapVlans2k OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..128))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A string of octets containing one bit per VLAN for
VLANS with VlanIndex values 1024 through 2047. The
first octet corresponds to VLANs with VlanIndex values
1024 through 1031; the second octet to VLANs 1032
through 1039 etc. The most significant bit of each
octet corresponds to the lowest VlanIndex value in that
octet.
For each VLAN that is mapped to this MSTP instance,
the bit corresponding to that VLAN is set to '1'.
Empty (zero) most significant octes are not mandatory."
::= { mstMapEntry 3 }
mstMapVlans3k OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..128))
ACCESS read-write
STATUS current
DESCRIPTION
"A string of octets containing one bit per VLAN for
VLANS with VlanIndex values 2048 through 3071. The
first octet corresponds to VLANs with VlanIndex values
of 2048 through 2055; the second octet to VLANs 2056
through 2063 etc. The most significant bit of each
octet corresponds to the lowest VlanIndex value in that
octet.
For each VLAN that is mapped to this MSTP instance,
the bit corresponding to that VLAN is set to '1'.
Empty (zero) most significant octes are not mandatory."
::= { mstMapEntry 4 }
mstMapVlans4k OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A string of octets containing one bit per VLAN for
VLANS with VlanIndex values 3072 through 4095. The
first octet corresponds to VLANs with VlanIndex values
3072 through 3079; the second octet to VLANs 3080
through 3087 etc. The most significant bit of each
octet corresponds to the lowest VlanIndex value in that
octet.
For each VLAN that is mapped to this MSTP instance,
the bit corresponding to that VLAN is set to '1'.
Empty (zero) most significant octes are not mandatory."
::= { mstMapEntry 5 }
mstMapRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { mstMapEntry 6 }
-- MSTP Vlan Table, map vlan to msti
mstVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF MstVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains one entry for each VlanId."
::= { mstp 30 }
mstVlanEntry OBJECT-TYPE
SYNTAX MstVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information regarding the instance to which each Vlan is mapped."
INDEX { mstVlanIndex }
::= { mstVlanTable 1 }
MstVlanEntry ::= SEQUENCE {
mstVlanIndex INTEGER,
mstVlanMstIndex MstiOrCistInstanceIndex
}
mstVlanIndex OBJECT-TYPE
SYNTAX INTEGER(1..4094)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The VlanId for which this entry contains the instance mapped."
::= { mstVlanEntry 1 }
mstVlanMstIndex OBJECT-TYPE
SYNTAX MstiOrCistInstanceIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An integer with values ranging from 0 to 64 that identify a
the CIST/MSTI instance to which this VLAN is mapped"
::= { mstVlanEntry 2 }
-- MSTP Port Table, information for all instance of a port
mstpPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF MstpPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains generic information about
every port that is associated with this bridge."
::= { mstp 40 }
mstpPortEntry OBJECT-TYPE
SYNTAX MstpPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of information for each port of the
bridge."
INDEX { mstpPortIndex }
::= { mstpPortTable 1 }
MstpPortEntry ::= SEQUENCE {
mstpPortIndex INTEGER,
mstpPortOperEdgePort TruthValue,
mstpPortOperPointToPointMAC TruthValue
}
mstpPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A unique value, greater than zero, for each Port.
The value for each interface sub-layer
must remain constant at least from one re-initialization
of the entity's network management system to the next re-
initialization."
::= { mstpPortEntry 1 }
mstpPortOperEdgePort OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
REFERENCE ""
::= { mstpPortEntry 2 }
mstpPortOperPointToPointMAC OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
REFERENCE ""
::= {mstpPortEntry 3}
-- MSTP Xst Table, Cist/Mst status/setting
mstpXstTable OBJECT-TYPE
SYNTAX SEQUENCE OF MstpXstEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"."
::= { mstp 50 }
mstpXstEntry OBJECT-TYPE
SYNTAX MstpXstEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"."
INDEX { mstpXstId }
::= { mstpXstTable 1 }
MstpXstEntry ::= SEQUENCE {
mstpXstId MstiOrCistInstanceIndex,
mstpXstBridgePriority Integer32,
mstpXstBridgeId BridgeId,
mstpXstInternalRootCost Integer32,
mstpXstRootPort INTEGER,
mstpXstTimeSinceTopologyChange TimeTicks,
mstpXstTopologyChangesCount Counter32
}
mstpXstId OBJECT-TYPE
SYNTAX MstiOrCistInstanceIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"0 means CIST."
::= { mstpXstEntry 1 }
mstpXstBridgePriority OBJECT-TYPE
SYNTAX Integer32 (0..61440)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge priority, in steps of 4096."
DEFVAL { 32768 }
::= { mstpXstEntry 2 }
mstpXstBridgeId OBJECT-TYPE
SYNTAX BridgeId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"."
::= { mstpXstEntry 3 }
mstpXstInternalRootCost OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"."
::= { mstpXstEntry 4 }
mstpXstRootPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"."
::= { mstpXstEntry 5 }
mstpXstTimeSinceTopologyChange OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"."
::= { mstpXstEntry 6 }
mstpXstTopologyChangesCount OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"."
::= { mstpXstEntry 7 }
-- MSTP Xst Port Table, Cist/Mst Port status/setting
mstpXstPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF MstpXstPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"."
::= { mstp 60 }
mstpXstPortEntry OBJECT-TYPE
SYNTAX MstpXstPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"."
REFERENCE
"."
INDEX { mstpXstPortXstId, mstpXstPortIndex }
::= { mstpXstPortTable 1 }
MstpXstPortEntry ::=
SEQUENCE {
mstpXstPortXstId MstiOrCistInstanceIndex,
mstpXstPortIndex INTEGER,
mstpXstPortEnable EnabledStatus,
mstpXstPortPriority Integer32,
mstpXstPortPathCost INTEGER,
mstpXstPortState INTEGER,
mstpXstPortDesignatedRoot BridgeId,
mstpXstPortDesignatedCost Integer32,
mstpXstPortDesignatedBridge BridgeId,
mstpXstPortDesignatedPort INTEGER
}
mstpXstPortXstId OBJECT-TYPE
SYNTAX MstiOrCistInstanceIndex
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"0 means CIST."
::= { mstpXstPortEntry 1 }
mstpXstPortIndex OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of mstpPortIndex of the Port
in mstpPortTable."
::= { mstpXstPortEntry 2 }
mstpXstPortEnable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"."
::= { mstpXstPortEntry 3 }
mstpXstPortPriority OBJECT-TYPE
SYNTAX Integer32 (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port priority, in steps of 16."
DEFVAL { 128 }
::= { mstpXstPortEntry 4 }
mstpXstPortPathCost OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"."
::= { mstpXstPortEntry 5 }
mstpXstPortState OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
discarding(1),
learning(2),
forwarding(3),
unknown(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"."
::= { mstpXstPortEntry 6 }
mstpXstPortDesignatedRoot OBJECT-TYPE
SYNTAX BridgeId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"."
::= { mstpXstPortEntry 7 }
mstpXstPortDesignatedCost OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"."
::= { mstpXstPortEntry 8 }
mstpXstPortDesignatedBridge OBJECT-TYPE
SYNTAX BridgeId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"."
::= { mstpXstPortEntry 9 }
mstpXstPortDesignatedPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"."
::= { mstpXstPortEntry 10 }
--MSTP Traps
mstpNotifications OBJECT IDENTIFIER ::= { mstp 70 }
newRoot NOTIFICATION-TYPE
OBJECTS {
mstpXstId
}
STATUS current
DESCRIPTION
""
::= { mstpNotifications 1 }
topologyChange NOTIFICATION-TYPE
OBJECTS {
mstpXstId
}
STATUS current
DESCRIPTION
""
::= { mstpNotifications 2 }
END