Observium_CE/mibs/zyxel/ZYXEL-ES2024A-MIB

2439 lines
71 KiB
Plaintext

ZYXEL-ES2024A-MIB DEFINITIONS ::= BEGIN
IMPORTS
Integer32, Unsigned32 FROM SNMPv2-SMI
TEXTUAL-CONVENTION FROM SNMPv2-TC
enterprises FROM RFC1155-SMI
MODULE-IDENTITY, OBJECT-TYPE
FROM SNMPv2-SMI -- RFC2578
RowStatus, DateAndTime, TruthValue, StorageType, PhysAddress
FROM SNMPv2-TC -- RFC2579
DisplayString
FROM RFC1213-MIB
EnabledStatus
FROM P-BRIDGE-MIB
PortList
FROM Q-BRIDGE-MIB
dot1dBasePort
FROM BRIDGE-MIB
InterfaceIndexOrZero -- RFC2863
FROM IF-MIB
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB -- RFC2571
InetAddressType, InetAddress
FROM INET-ADDRESS-MIB -- RFC2851
OperationResponseStatus
FROM DISMAN-PING-MIB
IpAddress
FROM SNMPv2-SMI
NOTIFICATION-TYPE
FROM SNMPv2-SMI
sysObjectID
FROM RFC1213-MIB;
zyxel OBJECT IDENTIFIER ::= { enterprises 890 }
products OBJECT IDENTIFIER ::= { zyxel 1 }
accessSwitch OBJECT IDENTIFIER ::= { products 5 }
esSeries OBJECT IDENTIFIER ::= { accessSwitch 8 }
es2024a OBJECT IDENTIFIER ::= { esSeries 16 }
-- sysInfo
sysInfo OBJECT IDENTIFIER ::= { es2024a 1 }
sysSwPlatformMajorVers OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SW platform major version, e.g. 3."
::= { sysInfo 1 }
sysSwPlatformMinorVers OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SW platform minor version, e.g. 50."
::= { sysInfo 2 }
sysSwModelString OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model letters, e.g. TJ"
::= { sysInfo 3 }
sysSwVersionControlNbr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Version control number, e.g. 0."
::= { sysInfo 4 }
sysSwDay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SW compilation day, e.g. 19."
::= { sysInfo 5 }
sysSwMonth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SW compilation month, e.g. 8."
::= { sysInfo 6 }
sysSwYear OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SW compilation year, e.g. 2004."
::= { sysInfo 7 }
sysHwMajorVers OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"HW major version number, e.g. 1."
::= { sysInfo 8 }
sysHwMinorVers OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"HW minor version number, e.g. 0."
::= { sysInfo 9 }
sysSerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serial number"
::= { sysInfo 10 }
-- rateLimitSetup
rateLimitSetup OBJECT IDENTIFIER ::= { es2024a 2 }
rateLimitState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ingress/egress rate limiting enabled/disabled for the switch."
::= { rateLimitSetup 1 }
-- rateLimitPortTable
rateLimitPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF RateLimitPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { rateLimitSetup 2 }
rateLimitPortEntry OBJECT-TYPE
SYNTAX RateLimitPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in rateLimitPortTable."
INDEX { dot1dBasePort }
::= { rateLimitPortTable 1 }
RateLimitPortEntry ::=
SEQUENCE {
rateLimitPortState EnabledStatus,
rateLimitPortIngRate INTEGER,
rateLimitPortEgrRate INTEGER
}
rateLimitPortState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ingress/egress rate limiting enabled/disabled on the port."
::= { rateLimitPortEntry 1 }
rateLimitPortIngRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ingress rate in Kbit/s. The range of FE port is between 64 and 100,000. For GE port, the range is between 64 and 1000,000."
::= { rateLimitPortEntry 2 }
rateLimitPortEgrRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Egress rate in Kbit/s. The range of FE port is between 64 and 100,000. For GE port, the range is between 64 and 1000,000."
::= { rateLimitPortEntry 3 }
-- brLimitSetup
brLimitSetup OBJECT IDENTIFIER ::= { es2024a 3 }
brLimitState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Broadcast/multicast/DLF rate limiting enabled/disabled for the switch."
::= { brLimitSetup 1 }
-- brLimitPortTable
brLimitPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF BrLimitPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { brLimitSetup 2 }
brLimitPortEntry OBJECT-TYPE
SYNTAX BrLimitPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in brLimitPortTable."
INDEX { dot1dBasePort }
::= { brLimitPortTable 1 }
BrLimitPortEntry ::=
SEQUENCE {
brLimitPortState EnabledStatus,
brLimitPortRate INTEGER
}
brLimitPortState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rate limiting enabled/disabled on the port."
::= { brLimitPortEntry 1 }
brLimitPortRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Allowed rate in in Kbit/s. The range of FE port is between 64 and 100,000. For GE port, the range is between 64 and 1000,000."
::= { brLimitPortEntry 2 }
-- portSecuritySetup
portSecuritySetup OBJECT IDENTIFIER ::= { es2024a 4 }
portSecurityState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { portSecuritySetup 1 }
portSecurityPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortSecurityPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { portSecuritySetup 2 }
portSecurityPortEntry OBJECT-TYPE
SYNTAX PortSecurityPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in portSecurityPortTable."
INDEX { dot1dBasePort }
::= { portSecurityPortTable 1 }
PortSecurityPortEntry ::=
SEQUENCE {
portSecurityPortState EnabledStatus,
portSecurityPortLearnState EnabledStatus,
portSecurityPortCount INTEGER
}
portSecurityPortState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port Security enabled/disabled on the port.
Active(1) means this port only accept frames from static MAC addresses that are configured for the port,
and dynamic MAC address frames up to the number specified by portSecurityPortCount object."
::= { portSecurityPortEntry 1 }
portSecurityPortLearnState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"MAC address learning enabled/disable on the port."
::= { portSecurityPortEntry 2 }
portSecurityPortCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of (dynamic) MAC addresses that may be learned on the port."
::= { portSecurityPortEntry 3 }
portSecurityMacFreeze OBJECT-TYPE
SYNTAX PortList
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This entry is used to execute MacFreeze action to port.
It's meaningless while reading this entry."
::= { portSecuritySetup 3 }
-- vlanTrunkPortTable
vlanTrunkSetup OBJECT IDENTIFIER ::= { es2024a 5 }
vlanTrunkPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF VlanTrunkPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { vlanTrunkSetup 1 }
vlanTrunkPortEntry OBJECT-TYPE
SYNTAX VlanTrunkPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in vlanTrunkPortTable."
INDEX { dot1dBasePort }
::= { vlanTrunkPortTable 1 }
VlanTrunkPortEntry ::=
SEQUENCE {
vlanTrunkPortState EnabledStatus
}
vlanTrunkPortState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"VlanTrunking enabled/disabled on the port.
Active(1) to allow frames belonging to unknown
VLAN groups to pass through the switch."
::= { vlanTrunkPortEntry 1 }
-- radius8021xSetup
radius8021xSetup OBJECT IDENTIFIER ::= { es2024a 6 }
radiusLoginPrecedence OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"1. Local Only
2. Local then RADIUS
3. RADIUS Only"
::= { radius8021xSetup 1 }
-- radiusAnd8021xServer
radiusAnd8021xServer OBJECT IDENTIFIER ::= { radius8021xSetup 2 }
radiusIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the RADIUS server."
::= { radiusAnd8021xServer 1 }
radiusUdpPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The UDP port of the RADIUS server."
::= { radiusAnd8021xServer 2 }
radiusSharedSecret OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Shared secret used for RADIUS and network element authentication."
::= { radiusAnd8021xServer 3 }
-- portAuthState
portAuthState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"802.1x port authentication enabled/disabled for the switch."
::= { radius8021xSetup 3 }
-- 8021xPortAuthTable
portAuthTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortAuthEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { radius8021xSetup 4 }
portAuthEntry OBJECT-TYPE
SYNTAX PortAuthEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in portAuthTable."
INDEX { dot1dBasePort }
::= { portAuthTable 1 }
PortAuthEntry ::=
SEQUENCE {
portAuthEntryState EnabledStatus,
portReAuthEntryState EnabledStatus,
portReAuthEntryTimer INTEGER
}
portAuthEntryState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"802.1x port authentication enabled or disabled on the port."
::= { portAuthEntry 1 }
portReAuthEntryState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"802.1x port re-authentication enabled or disabled on the port."
::= { portAuthEntry 2 }
portReAuthEntryTimer OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Re-authentication timer in seconds."
::= { portAuthEntry 3 }
-- snmpSetup
snmpSetup OBJECT IDENTIFIER ::= { es2024a 7 }
snmpGetCommunity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { snmpSetup 1 }
snmpSetCommunity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { snmpSetup 2 }
snmpTrapCommunity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { snmpSetup 3 }
-- snmpTrapDestTable
snmpTrapDestTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnmpTrapDestEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { snmpSetup 4 }
snmpTrapDestEntry OBJECT-TYPE
SYNTAX SnmpTrapDestEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in snmpTrapDestTable."
INDEX { snmpTrapDestIP }
::= { snmpTrapDestTable 1 }
SnmpTrapDestEntry ::=
SEQUENCE {
snmpTrapDestIP IpAddress,
snmpTrapDestRowStatus RowStatus
}
snmpTrapDestIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"IP address of trap destination."
::= { snmpTrapDestEntry 1 }
snmpTrapDestRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { snmpTrapDestEntry 2 }
-- dateTimeServerSetup
dateTimeServerSetup OBJECT IDENTIFIER ::= { es2024a 8 }
dateTimeServerType OBJECT-TYPE
SYNTAX INTEGER {
none(1),
daytime(2),
time(3),
ntp(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time service protocol."
::= { dateTimeServerSetup 1 }
dateTimeServerIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of time server."
::= { dateTimeServerSetup 2 }
dateTimeZone OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time difference between UTC. Ex: +01"
::= { dateTimeServerSetup 3 }
dateTimeNewDateYear OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The new date in year."
::= { dateTimeServerSetup 4 }
dateTimeNewDateMonth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The new date in month."
::= { dateTimeServerSetup 5 }
dateTimeNewDateDay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The new date in day."
::= { dateTimeServerSetup 6 }
dateTimeNewTimeHour OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The new time in hour."
::= { dateTimeServerSetup 7 }
dateTimeNewTimeMinute OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The new time in minute."
::= { dateTimeServerSetup 8 }
dateTimeNewTimeSecond OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The new time in second."
::= { dateTimeServerSetup 9 }
-- sysMgmt
sysMgmt OBJECT IDENTIFIER ::= { es2024a 9 }
sysMgmtConfigSave OBJECT-TYPE
SYNTAX INTEGER {
config(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If setting value is given, the variable write index will be set and running-config will be written to the assigned configuration file.
If not, running-config will be written to the booting one."
::= { sysMgmt 1 }
sysMgmtBootupConfig OBJECT-TYPE
SYNTAX INTEGER {
config(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The setting value (read index) will be written into non-volatile memory.
While rebooting, the variable write index is equal to read index initially.
You can change the value of write index by CLI / MIB."
::= { sysMgmt 2 }
sysMgmtReboot OBJECT-TYPE
SYNTAX INTEGER {
nothing(0),
reboot(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reboot switch from SNMP. 1:Reboot, 0:Nothing"
::= { sysMgmt 3 }
sysMgmtDefaultConfig OBJECT-TYPE
SYNTAX INTEGER {
nothing(0),
reset-to-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Erase running config and reset to default."
::= { sysMgmt 4 }
sysMgmtLastActionStatus OBJECT-TYPE
SYNTAX INTEGER {
none(0),
success(1),
fail(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display status of last mgmt action."
::= { sysMgmt 5 }
-- layer2Setup
layer2Setup OBJECT IDENTIFIER ::= { es2024a 10 }
vlanTypeSetup OBJECT-TYPE
SYNTAX INTEGER {
dot1Q(1),
port-based(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 1 }
igmpSnoopingStateSetup OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 2 }
tagVlanPortIsolationState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 3 }
stpState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 4 }
tagVlanIngressCheckState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { layer2Setup 5 }
-- ipSetup
ipSetup OBJECT IDENTIFIER ::= { es2024a 11 }
dnsIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { ipSetup 1 }
defaultMgmtIpSetup OBJECT IDENTIFIER ::= { ipSetup 2 }
defaultMgmtIpType OBJECT-TYPE
SYNTAX INTEGER {
dhcp-client(0),
static-ip(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { defaultMgmtIpSetup 1 }
defaultMgmtVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { defaultMgmtIpSetup 2 }
defaultMgmtStaticIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { defaultMgmtIpSetup 3 }
defaultMgmtStaticSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { defaultMgmtIpSetup 4 }
defaultMgmtStaticGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { defaultMgmtIpSetup 5 }
-- inbandIpTable
maxNumOfMgmtIp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ipSetup 3 }
mgmtIpTable OBJECT-TYPE
SYNTAX SEQUENCE OF MgmtIpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { ipSetup 6 }
mgmtIpEntry OBJECT-TYPE
SYNTAX MgmtIpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in mgmtIpTable."
INDEX { mgmtEntryIp, mgmtEntryVid }
::= { mgmtIpTable 1 }
MgmtIpEntry ::=
SEQUENCE {
mgmtEntryIp IpAddress,
mgmtEntrySubnetMask IpAddress,
mgmtEntryGateway IpAddress,
mgmtEntryVid INTEGER,
mgmtEntryManageable EnabledStatus,
mgmtEntryRowStatus RowStatus
}
mgmtEntryIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mgmtIpEntry 1 }
mgmtEntrySubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mgmtIpEntry 2 }
mgmtEntryGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mgmtIpEntry 3 }
mgmtEntryVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { mgmtIpEntry 4 }
mgmtEntryManageable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mgmtIpEntry 5 }
mgmtEntryRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { mgmtIpEntry 6 }
-- filterSetup
filterSetup OBJECT IDENTIFIER ::= { es2024a 12 }
-- filterTable
filterTable OBJECT-TYPE
SYNTAX SEQUENCE OF FilterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { filterSetup 1 }
filterEntry OBJECT-TYPE
SYNTAX FilterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in filterTable."
INDEX { filterMacAddr, filterVid }
::= { filterTable 1 }
FilterEntry ::=
SEQUENCE {
filterName DisplayString,
filterMacAddr PhysAddress,
filterVid INTEGER,
filterRowStatus RowStatus
}
filterName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { filterEntry 1 }
filterMacAddr OBJECT-TYPE
SYNTAX PhysAddress
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { filterEntry 2 }
filterVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { filterEntry 3 }
filterRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { filterEntry 4 }
-- mirrorSetup
mirrorSetup OBJECT IDENTIFIER ::= { es2024a 13 }
-- mirrorState
mirrorState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mirrorSetup 1 }
mirrorMonitorPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mirrorSetup 2 }
mirrorIngActionState OBJECT-TYPE
SYNTAX INTEGER {
all(0),
destination-mac(1),
source-mac(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mirrorSetup 3 }
mirrorIngMacAddr OBJECT-TYPE
SYNTAX PhysAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mirrorSetup 4 }
mirrorEgrActionState OBJECT-TYPE
SYNTAX INTEGER {
all(0),
destination-mac(1),
source-mac(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mirrorSetup 5 }
mirrorEgrMacAddr OBJECT-TYPE
SYNTAX PhysAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mirrorSetup 6 }
-- mirrorTable
mirrorTable OBJECT-TYPE
SYNTAX SEQUENCE OF MirrorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { mirrorSetup 7 }
mirrorEntry OBJECT-TYPE
SYNTAX MirrorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in mirrorTable."
INDEX { dot1dBasePort }
::= { mirrorTable 1 }
MirrorEntry ::=
SEQUENCE {
mirrorMirroredState EnabledStatus,
mirrorDirection INTEGER
}
mirrorMirroredState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mirrorEntry 1 }
mirrorDirection OBJECT-TYPE
SYNTAX INTEGER {
ingress(0),
egress(1),
both(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { mirrorEntry 2 }
-- aggrSetup
aggrSetup OBJECT IDENTIFIER ::= { es2024a 14 }
aggrState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { aggrSetup 1 }
aggrSystemPriority OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { aggrSetup 2 }
-- aggrGroupTable
aggrGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF AggrGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { aggrSetup 3 }
aggrGroupEntry OBJECT-TYPE
SYNTAX AggrGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in aggrGroupTable."
INDEX { aggrGroupIndex }
::= { aggrGroupTable 1 }
AggrGroupEntry ::=
SEQUENCE {
aggrGroupIndex INTEGER,
aggrGroupState EnabledStatus,
aggrGroupDynamicState EnabledStatus
}
aggrGroupIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { aggrGroupEntry 1 }
aggrGroupState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { aggrGroupEntry 2 }
aggrGroupDynamicState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { aggrGroupEntry 3 }
-- aggrPortTable
aggrPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF AggrPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { aggrSetup 4 }
aggrPortEntry OBJECT-TYPE
SYNTAX AggrPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in aggrPortTable."
INDEX { dot1dBasePort }
::= { aggrPortTable 1 }
AggrPortEntry ::=
SEQUENCE {
aggrPortGroup INTEGER,
aggrPortDynamicStateTimeout INTEGER
}
aggrPortGroup OBJECT-TYPE
SYNTAX INTEGER {
none(0),
t1(1),
t2(2),
t3(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { aggrPortEntry 1 }
aggrPortDynamicStateTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { aggrPortEntry 2 }
-- accessCtlSetup
accessCtlSetup OBJECT IDENTIFIER ::= { es2024a 15 }
-- accessCtlTable
accessCtlTable OBJECT-TYPE
SYNTAX SEQUENCE OF AccessCtlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { accessCtlSetup 1 }
accessCtlEntry OBJECT-TYPE
SYNTAX AccessCtlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in accessCtlTable."
INDEX { accessCtlService }
::= { accessCtlTable 1 }
AccessCtlEntry ::=
SEQUENCE {
accessCtlService INTEGER,
accessCtlEnable EnabledStatus,
accessCtlServicePort INTEGER,
accessCtlTimeout INTEGER
}
accessCtlService OBJECT-TYPE
SYNTAX INTEGER {
telnet(1),
ssh(2),
ftp(3),
http(4),
https(5),
icmp(6),
snmp(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { accessCtlEntry 1 }
accessCtlEnable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { accessCtlEntry 2 }
accessCtlServicePort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { accessCtlEntry 3 }
accessCtlTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { accessCtlEntry 4 }
-- securedClientTable
securedClientTable OBJECT-TYPE
SYNTAX SEQUENCE OF SecuredClientEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { accessCtlSetup 2 }
securedClientEntry OBJECT-TYPE
SYNTAX SecuredClientEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in securedClientTable."
INDEX { securedClientIndex }
::= { securedClientTable 1 }
SecuredClientEntry ::=
SEQUENCE {
securedClientIndex INTEGER,
securedClientEnable EnabledStatus,
securedClientStartIp IpAddress,
securedClientEndIp IpAddress,
securedClientService BITS
}
securedClientIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { securedClientEntry 1 }
securedClientEnable OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { securedClientEntry 2 }
securedClientStartIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { securedClientEntry 3 }
securedClientEndIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { securedClientEntry 4 }
securedClientService OBJECT-TYPE
SYNTAX BITS {
telnet(0),
ftp(1),
http(2),
icmp(3),
snmp(4),
ssh(5),
https(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { securedClientEntry 5 }
-- queuingMethodSetup
queuingMethodSetup OBJECT IDENTIFIER ::= { es2024a 16 }
queuingMethodType OBJECT-TYPE
SYNTAX INTEGER {
strictly-priority(0),
weighted-round-robin-scheduling(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { queuingMethodSetup 1 }
-- QueuingMethodTable
queuingMethodTable OBJECT-TYPE
SYNTAX SEQUENCE OF QueuingMethodEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { queuingMethodSetup 2 }
queuingMethodEntry OBJECT-TYPE
SYNTAX QueuingMethodEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in queuingMethodTable."
INDEX { queuingMethodQueue }
::= {queuingMethodTable 1}
QueuingMethodEntry ::=
SEQUENCE {
queuingMethodQueue INTEGER,
queuingMethodWeight INTEGER
}
queuingMethodQueue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"0...3"
::= { queuingMethodEntry 1 }
queuingMethodWeight OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"1...15"
::= { queuingMethodEntry 2 }
-- staticRouteSetup
staticRouteSetup OBJECT IDENTIFIER ::= { es2024a 17 }
maxNumberOfStaticRoutes OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { staticRouteSetup 1 }
-- staticRouteTable
staticRouteTable OBJECT-TYPE
SYNTAX SEQUENCE OF StaticRouteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { staticRouteSetup 2 }
staticRouteEntry OBJECT-TYPE
SYNTAX StaticRouteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in staticRouteTable."
INDEX { staticRouteIp, staticRouteMask }
::= { staticRouteTable 1 }
StaticRouteEntry ::=
SEQUENCE {
staticRouteName DisplayString,
staticRouteIp IpAddress,
staticRouteMask IpAddress,
staticRouteGateway IpAddress,
staticRouteMetric INTEGER,
staticRouteRowStatus RowStatus
}
staticRouteName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { staticRouteEntry 1 }
staticRouteIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { staticRouteEntry 2 }
staticRouteMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { staticRouteEntry 3 }
staticRouteGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { staticRouteEntry 4 }
staticRouteMetric OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { staticRouteEntry 5 }
staticRouteRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { staticRouteEntry 6 }
-- arpInfo
arpInfo OBJECT IDENTIFIER ::= { es2024a 18 }
-- arpTable
arpTable OBJECT-TYPE
SYNTAX SEQUENCE OF ArpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { arpInfo 1 }
arpEntry OBJECT-TYPE
SYNTAX ArpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in arpTable."
INDEX { arpIndex }
::= { arpTable 1 }
ArpEntry ::=
SEQUENCE {
arpIndex INTEGER,
arpIpAddr IpAddress,
arpMacAddr PhysAddress,
arpMacVid INTEGER,
arpType INTEGER
}
arpIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpEntry 1 }
arpIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpEntry 2 }
arpMacAddr OBJECT-TYPE
SYNTAX PhysAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpEntry 3 }
arpMacVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpEntry 4 }
arpType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { arpEntry 5 }
-- portOpModeSetup
portOpModeSetup OBJECT IDENTIFIER ::= { es2024a 19 }
-- portOpModePortTable
portOpModePortTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortOpModePortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { portOpModeSetup 1 }
portOpModePortEntry OBJECT-TYPE
SYNTAX PortOpModePortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in portOpModePortTable."
INDEX { dot1dBasePort }
::= { portOpModePortTable 1 }
PortOpModePortEntry ::=
SEQUENCE {
portOpModePortSpeedDuplex INTEGER,
portOpModePortFlowCntl INTEGER,
portOpModePortName OCTET STRING,
portOpModePortModuleType INTEGER,
portOpModePortLinkUpType INTEGER,
portOpModePortIntrusionLock EnabledStatus,
portOpModePortLBTestStatus INTEGER
}
portOpModePortSpeedDuplex OBJECT-TYPE
SYNTAX INTEGER {
auto(0),
speed-10-half(1),
speed-10-full(2),
speed-100-half(3),
speed-100-full(4),
speed-1000-full(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { portOpModePortEntry 1 }
portOpModePortFlowCntl OBJECT-TYPE
SYNTAX INTEGER {
off(0),
on(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { portOpModePortEntry 2 }
portOpModePortName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { portOpModePortEntry 3 }
portOpModePortModuleType OBJECT-TYPE
SYNTAX INTEGER {
fast-ethernet-10-100(0),
gigabit-ethernet-100-1000(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { portOpModePortEntry 4 }
portOpModePortLinkUpType OBJECT-TYPE
SYNTAX INTEGER {
down(0),
copper(1),
fiber(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { portOpModePortEntry 5 }
portOpModePortIntrusionLock OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { portOpModePortEntry 6 }
portOpModePortLBTestStatus OBJECT-TYPE
SYNTAX INTEGER {
none(0),
underTesting(1),
success(2),
fail(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This entry display latest loopback test status of port while performing loopback test."
::= { portOpModePortEntry 7 }
-- portBasedVlanSetup
portBasedVlanSetup OBJECT IDENTIFIER ::= { es2024a 20 }
-- portBasedVlanPortListTable
portBasedVlanPortListTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortBasedVlanPortListEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { portBasedVlanSetup 1 }
portBasedVlanPortListEntry OBJECT-TYPE
SYNTAX PortBasedVlanPortListEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in portBasedVlanPortListTable."
INDEX { dot1dBasePort }
::= { portBasedVlanPortListTable 1 }
PortBasedVlanPortListEntry ::=
SEQUENCE {
portBasedVlanPortListMembers OCTET STRING
}
portBasedVlanPortListMembers OBJECT-TYPE
SYNTAX PortList
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { portBasedVlanPortListEntry 1 }
-- diffservSetup
diffservSetup OBJECT IDENTIFIER ::= { es2024a 21 }
diffservState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { diffservSetup 1 }
-- diffservMapTable
diffservMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF DiffservMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { diffservSetup 2 }
diffservMapEntry OBJECT-TYPE
SYNTAX DiffservMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in diffservMapTable."
INDEX { diffservMapDscp }
::= { diffservMapTable 1 }
DiffservMapEntry ::=
SEQUENCE {
diffservMapDscp INTEGER,
diffservMapPriority INTEGER
}
diffservMapDscp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"0-63"
::= { diffservMapEntry 1 }
diffservMapPriority OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"0-7"
::= { diffservMapEntry 2 }
-- diffservPortTable
diffservPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF DiffservPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { diffservSetup 3 }
diffservPortEntry OBJECT-TYPE
SYNTAX DiffservPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in diffservPortTable."
INDEX { dot1dBasePort }
::= { diffservPortTable 1 }
DiffservPortEntry ::=
SEQUENCE {
diffservPortState EnabledStatus
}
diffservPortState OBJECT-TYPE
SYNTAX EnabledStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { diffservPortEntry 1 }
-- clusterSetup
clusterSetup OBJECT IDENTIFIER ::= { es2024a 22 }
-- clusterManager
clusterManager OBJECT IDENTIFIER ::= { clusterSetup 1 }
clusterMaxNumOfManager OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterManager 1 }
-- clusterManagerTable
clusterManagerTable OBJECT-TYPE
SYNTAX SEQUENCE OF ClusterManagerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { clusterManager 2 }
clusterManagerEntry OBJECT-TYPE
SYNTAX ClusterManagerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in clusterManagerTable."
INDEX { clusterManagerVid }
::= { clusterManagerTable 1 }
ClusterManagerEntry ::=
SEQUENCE {
clusterManagerVid INTEGER,
clusterManagerName DisplayString,
clusterManagerRowStatus RowStatus
}
clusterManagerVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterManagerEntry 1 }
clusterManagerName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { clusterManagerEntry 2 }
clusterManagerRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { clusterManagerEntry 3 }
-- clusterMembers
clusterMembers OBJECT IDENTIFIER ::= { clusterSetup 2 }
clusterMaxNumOfMember OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterMembers 1 }
-- clusterMemberTable
clusterMemberTable OBJECT-TYPE
SYNTAX SEQUENCE OF ClusterMemberEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { clusterMembers 2 }
clusterMemberEntry OBJECT-TYPE
SYNTAX ClusterMemberEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in clusterMemberTable."
INDEX { clusterMemberMac }
::= { clusterMemberTable 1 }
ClusterMemberEntry ::=
SEQUENCE {
clusterMemberMac DisplayString,
clusterMemberName DisplayString,
clusterMemberModel DisplayString,
clusterMemberPassword DisplayString,
clusterMemberRowStatus RowStatus
}
clusterMemberMac OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterMemberEntry 1 }
clusterMemberName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterMemberEntry 2 }
clusterMemberModel OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterMemberEntry 3 }
clusterMemberPassword OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { clusterMemberEntry 4 }
clusterMemberRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-create
STATUS mandatory
DESCRIPTION
""
::= { clusterMemberEntry 5 }
-- clusterCandidates
clusterCandidates OBJECT IDENTIFIER ::= { clusterSetup 3 }
-- clusterCandidateTable
clusterCandidateTable OBJECT-TYPE
SYNTAX SEQUENCE OF ClusterCandidateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { clusterCandidates 1 }
clusterCandidateEntry OBJECT-TYPE
SYNTAX ClusterCandidateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in clusterCandidateTable."
INDEX { clusterCandidateMac }
::= { clusterCandidateTable 1 }
ClusterCandidateEntry ::=
SEQUENCE {
clusterCandidateMac DisplayString,
clusterCandidateName DisplayString,
clusterCandidateModel DisplayString
}
clusterCandidateMac OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterCandidateEntry 1 }
clusterCandidateName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterCandidateEntry 2 }
clusterCandidateModel OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterCandidateEntry 3 }
-- clusterStatus
clusterStatus OBJECT IDENTIFIER ::= { clusterSetup 4 }
clusterStatusRole OBJECT-TYPE
SYNTAX INTEGER {
none(0),
manager(1),
member(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterStatus 1 }
clusterStatusManager OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterStatus 2 }
clsuterStatusMaxNumOfMember OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterStatus 3 }
-- clusterStatusMemberTable
clusterStatusMemberTable OBJECT-TYPE
SYNTAX SEQUENCE OF ClusterStatusMemberEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { clusterStatus 4 }
clusterStatusMemberEntry OBJECT-TYPE
SYNTAX ClusterStatusMemberEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in clusterStatusMemberTable."
INDEX { clusterStatusMemberMac }
::= { clusterStatusMemberTable 1 }
ClusterStatusMemberEntry ::=
SEQUENCE {
clusterStatusMemberMac DisplayString,
clusterStatusMemberName DisplayString,
clusterStatusMemberModel DisplayString,
clusterStatusMemberStatus INTEGER
}
clusterStatusMemberMac OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterStatusMemberEntry 1 }
clusterStatusMemberName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterStatusMemberEntry 2 }
clusterStatusMemberModel OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterStatusMemberEntry 3 }
clusterStatusMemberStatus OBJECT-TYPE
SYNTAX INTEGER {
error(0),
online(1),
offline(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { clusterStatusMemberEntry 4 }
--fault MIB
faultMIB MODULE-IDENTITY
LAST-UPDATED "200411031200Z" -- YYYY/MM/DD, HH/MM
ORGANIZATION "ZyXEL"
CONTACT-INFO ""
DESCRIPTION
"Fault event table definitions"
::= { es2024a 26 }
-- **************************************************************************
-- Local Textual Conventions
-- **************************************************************************
UtcTimeStamp ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Universal Time Coordinated as a 32-bit value that designates
the number of seconds since Jan 1, 1970 12:00AM."
SYNTAX Unsigned32
EventIdNumber ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This textual convention describes the index that uniquely
identifies a fault event type in the entire system. Every fault
event type, e.g. link down, has a unique EventIdNumber."
SYNTAX Integer32
EventSeverity ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This textual convention describes the severity of a fault event.
The decreasing order of severity is shown in the textual
convention."
SYNTAX INTEGER{
critical (1),
major (2),
minor (3),
informational (4)
}
EventServiceAffective ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This textual convention indicates whether an event is immediately
service affecting or not."
SYNTAX INTEGER{
noServiceAffected (1),
serviceAffected (2)
}
InstanceType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This textual convention describes the type of an instanceId
associated with each event and by that means specifies how
the instanceId variable should be intepreted.
Various instanceId types are specified below to enable fault
monitoring for different kind of devices from fixed
configuration pizza boxes to multi chassis nodes. All
instanceId types may not need to be used in every device
type.
Note also that instanceId semantics are element type dependent
(e.g. different kind of interface naming conventions may be used)
and thus instanceId usage may vary from element to element.
=========================================================================
Type Description Example form
of InstanceId
=========================================================================
unknown (1) unknown type - Irrelevant-
-------------------------------------------------------------------------
node (2) Associated with events originating from 1
the node. Used for general events that (Node number)
can not be associated with any specific
block. InstanceId value 1 is used for
single node equipment.
-------------------------------------------------------------------------
shelf (3) Associated with events originating from 1
the shelf. In the case of fixed (shelf number)
configuration devices this type is used
for events that are associated with the
physical enclosure, e.g. faults related
to fan etc. InstanceId value 1 is used
for single self equipment.
-------------------------------------------------------------------------
line (4) Associated with events originating from
physical interfaces or associated
components such as line cards.
InstanceId usage examples for faults
originating from:
- Physical port: Simply port number, e.g. .......1
-------------------------------------------------------------------------
switch (5) Associated with events originating from 1
from a switch chip or a switch card. (switch number)
For single switch equipment InstanceId
value 1 is used, for multi swich nodes
InstanceId semantics if for further
study.
-------------------------------------------------------------------------
lsp (6) Associated with events originating from 1
a particular lsp. (lsp index)
NOTE: In this case the InstanceName
contains the lsp name and InstanceId
contains lsp index.
-------------------------------------------------------------------------
l2Interface(7) Associated with events originating from - TBD -
a particular layer 2 interface. Used for
layer 2 related events such as L2 control
protocol faults. InstanceId semantics is
for further study.
-------------------------------------------------------------------------
l3Interface(8) Associated with events originating from - TBD -
a particular layer 3 interface. Used for
layer 3 related events such as L3 control
protocol faults. InstanceId semantics is
for further study.
-------------------------------------------------------------------------
rowIndex (9) Associated with events reporting about a
'logical' or conceptual table that consists
of rows. The Instance Id is the index/key
for a row in the table. The format of the
Instance Id will simply be a series of decimal
numbers seperated by a '.':
========================================================================="
SYNTAX INTEGER {
unknown (1),
node (2),
shelf (3),
line (4),
switch (5),
lsp (6),
l2Interface(7),
l3Interface(8),
rowIndex(9)
}
-- *****************************************************************************
-- Top level structure of this MIB.
-- *****************************************************************************
eventObjects OBJECT IDENTIFIER ::= { faultMIB 1 }
-- *****************************************************************************
-- Event Table
--
-- Event table reports all currently active fault events. Only normal type of
-- faults (i.e. faults that are not automatically and immediately cleared) are
-- present in the event table. Delta faults (i.e. faults that are automatically
-- cleared) are reported only by using trap messages.
-- *****************************************************************************
eventTable OBJECT-TYPE
SYNTAX SEQUENCE OF EventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of currently active fault events. All faults
of normal type regardless of their severity level
are recorded in the event table. When a normal
type fault is cleared it is deleted from the event
table."
::= { eventObjects 1 }
eventEntry OBJECT-TYPE
SYNTAX EventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing information about an
event in the event table."
INDEX { eventSeqNum }
::= { eventTable 1 }
EventEntry ::=
SEQUENCE {
eventSeqNum Integer32,
eventEventId EventIdNumber,
eventName DisplayString,
eventInstanceType InstanceType,
eventInstanceId DisplayString,
eventInstanceName DisplayString,
eventSeverity EventSeverity,
eventSetTime UtcTimeStamp,
eventDescription DisplayString,
eventServAffective EventServiceAffective
}
eventSeqNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable represents the sequence number of an event.
Sequence number is incremented monotonically starting
from 0 until it reaches its maximum and wraps around back
to 0.
Sequence number is incremented when
- the state of a normal type fault is set on (the same sequence
number is present in the events table as well as in the trap
that is sent to notify about the fault on event)
- delta event occurs (sequence number present in trap message)
- the state of a normal type fault is set off (sequence number
present in trap that is sent to notify for clearing)."
::= { eventEntry 1 }
eventEventId OBJECT-TYPE
SYNTAX EventIdNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable represents the event ID which uniquely
identifies the event in the entire system."
::= { eventEntry 2 }
eventName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..40))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable represents the name of the event, for
example 'Ethernet Link Down'"
::= { eventEntry 3 }
eventInstanceType OBJECT-TYPE
SYNTAX InstanceType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable represents the type of InstanceId of a
particular event in the event table. In brief
the instanceType refers to the type of sub-component
generating this event in the system, for example
switch (5). For more details see the textual
conventions section.
AFFECTS: eventInstanceId,
eventInstanceName"
::= { eventEntry 4 }
eventInstanceId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable represents the InstanceId of a particular
event in the event current table. In brief the instanceId
refers to the sub-component generating this event in the
system, for example '1' for port 1. For more details see
the textual conventions section.
DEPENDS ON: eventInstanceType"
::= { eventEntry 5 }
eventInstanceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable is mainly used to store additional information
about the sub-component that is generating an event. For
example this field may specify what cooling fan is faulty.
DEPENDS ON: eventInstanceType"
::= { eventEntry 6 }
eventSeverity OBJECT-TYPE
SYNTAX EventSeverity
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable dictates the urgency of action when a event
occurs. There are four severity levels - Critical, Major,
Minor, and Informational. Critical events are those, which
require immediate operator intervention to prevent/reduce
system down time. Major events require quick attention and
Minor events possibly require some attention. Informational
events indicate the occurrence of events that may need to be
investigated."
::= { eventEntry 7 }
eventSetTime OBJECT-TYPE
SYNTAX UtcTimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This table contains only normal events and this variable
represents the time when the event become active, i.e. the
number of seconds since Jan 1, 1970 12:00AM."
::= { eventEntry 8 }
eventDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable contains a description of the event and reasons
behind the event. This is a free format alpha-numeric string
that is set by the entity generating this event. This variable
may be empty if there is no usefull information to report.
The maximum length of this string is 255 characters."
::= { eventEntry 9 }
eventServAffective OBJECT-TYPE
SYNTAX EventServiceAffective
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates whether the event is service affective or not"
::= { eventEntry 10 }
-- fault Trap MIB
faultTrapsMIB MODULE-IDENTITY
LAST-UPDATED "200411011200Z" -- YYYY/MM/DD, HH/MM
ORGANIZATION "ZyXEL"
CONTACT-INFO ""
DESCRIPTION
"Fault event trap definitions"
::= { es2024a 27 }
trapInfoObjects OBJECT IDENTIFIER ::= { faultTrapsMIB 1}
trapNotifications OBJECT IDENTIFIER ::= { faultTrapsMIB 2}
-- **************************************************************************
-- Local Textual Conventions
-- **************************************************************************
EventPersistence ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This textual convention indicates whether the event is delta
(automatically and immediately cleared) or normal (not
automatically cleared)."
SYNTAX INTEGER{
normal (1),
delta (2)
}
-- **************************************************************************
-- Trap information object definitions
-- **************************************************************************
trapRefSeqNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the former sequence number of a cleared event
in the event table. Not intended to read but only used in
trap notifications."
::= { trapInfoObjects 1 }
trapPersistence OBJECT-TYPE
SYNTAX EventPersistence
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the event is delta (automatically and
immediately cleared) or normal (not automatically cleared).
Not intended to read but only used in trap notifications."
::= { trapInfoObjects 2 }
trapSenderNodeId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Represents the node ID of the sending network element. If not
supported should be set to 0. Not intended to read but only
used in trap notifications."
::= { trapInfoObjects 3 }
-- ***************************************************************************
-- Trap definitions
-- ***************************************************************************
eventOnTrap NOTIFICATION-TYPE
OBJECTS {
eventSeqNum,
eventEventId,
eventName,
eventSetTime,
eventSeverity,
eventInstanceType,
eventInstanceId,
eventInstanceName,
eventServAffective,
eventDescription,
trapPersistence,
trapSenderNodeId,
sysObjectID}
STATUS current
DESCRIPTION
"This trap is used to inform network management system that a delta
fault event (events that are automatically cleared) has occured
or a normal fault event (not automatically cleared) state has
been set on.
Objects are used as follows:
- eventSeqNum is the sequence number of the event. For normal
type of events must equal to the sequence number of the event
in the events table.
- eventEventId specifies what fault event has occured.
- eventName specifies the name of the fault event.
- eventSetTime indicates when fault event has occured
(delta events) or when fault has been set on (normal events).
- eventSeverity reports the severity level of the event.
- eventInstanceType indicates what kind of object is faulty.
- eventInstanceId specifies what instance is faulty.
- eventInstanceName may contain textual description for
the faulty object.
- eventServAffective specifies whether the event is
immediately service affcetive.
- eventDescription reports possible additional information about the event.
- trapPersistence tells whether this event is a delta or normal event.
- trapSenderNodeId specifies the node ID of the sending network element if
configuring it is supported for the network element, otherwise 0.
- sysObjectID specifies what kind of equipment reports the fault event.
For more information see the eventTable specification"
::= { trapNotifications 1 }
eventClearedTrap NOTIFICATION-TYPE
OBJECTS {
eventSeqNum,
eventEventId,
eventSetTime,
eventInstanceType,
eventInstanceId,
trapRefSeqNum,
trapSenderNodeId,
sysObjectID}
STATUS current
DESCRIPTION
"This trap is used to inform network management system that a normal
type fault event has been cleared (state set off).
Objects are used as follows:
- eventSeqNum is the sequence number of the this clearing event. Note that
the sequence number of the cleared event is reported in the trapRefSeqNum
object.
- eventEventId specifies what event has been cleared.
- eventSetTime indicates when fault event has been cleared.
- eventInstanceType indicates what kind of object has been
faulty.
- eventInstanceId specifies what instance has been faulty.
- trapRefSeqNum specifies the sequence number of the cleared event (i.e.
the sequence number was assigned for the event in the events table).
- trapSenderNodeId specifies the node ID of the sending network element if
configuring it is supported for the network element, otherwise 0.
- sysObjectID specifies what kind of equipment reports the clearing event.
For more information see the eventTable specification"
::= { trapNotifications 2 }
END