-- ZyXEL Communications Corporation
|
|
-- Private Enterprise MIB definition
|
|
|
|
-- This file describes the ZyXEL Communications Corporation Enterprise MIB.
|
|
-- It contains ZyXEL products OIDs, and common managed objects.
|
|
|
|
-- $Log: ZYXEL-CABLE-DIAG-MIB.mib $
|
|
-- Revision 1.0 2016/10/19 18:00:00 Tiger Fu
|
|
-- Revision 1.1 2016/11/03 14:00:00 Tiger Fu
|
|
-- Initial revision
|
|
|
|
ZYXEL-CABLE-DIAG-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- ================================================
|
|
-- Include related libraries
|
|
-- ================================================
|
|
|
|
IMPORTS
|
|
enterprises FROM RFC1155-SMI
|
|
OBJECT-TYPE FROM SNMPv2-SMI
|
|
esMgmt FROM ZYXEL-ES-SMI
|
|
ifIndex FROM IF-MIB;
|
|
|
|
-- ================================================
|
|
-- ROOT(Cable Diagnostic)
|
|
-- ================================================
|
|
zyxelCableDiagnostic MODULE-IDENTITY
|
|
LAST-UPDATED "201610190000Z"
|
|
ORGANIZATION "Enterprise Solution ZyXEL"
|
|
CONTACT-INFO
|
|
""
|
|
DESCRIPTION
|
|
"The subtree for cable diagnostic."
|
|
::= { esMgmt 112 }
|
|
|
|
-- ================================================
|
|
-- Cable Diagnostic Setup
|
|
-- ================================================
|
|
zyxelCableDiagnosticSetup OBJECT IDENTIFIER ::= { zyxelCableDiagnostic 1 }
|
|
|
|
-- ================================================
|
|
-- Cable Diagnostic Port Table
|
|
-- ================================================
|
|
zyxelCableDiagnosticPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ZyxelCableDiagnosticPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table containing information about cable diagnostic
|
|
test on the device's interfaces. An entry appears in
|
|
this table for each interface which is capable to run
|
|
cable diagnostic test."
|
|
::= { zyxelCableDiagnosticSetup 1 }
|
|
|
|
-- ================================================
|
|
-- Cable Diagnostic Port Entry
|
|
-- ================================================
|
|
zyxelCableDiagnosticPortEntry OBJECT-TYPE
|
|
SYNTAX ZyxelCableDiagnosticPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the zyxelCableDiagnosticPortTable, containing the information
|
|
about cable diagnostic test on an interface."
|
|
INDEX { ifIndex }
|
|
::= { zyxelCableDiagnosticPortTable 1 }
|
|
|
|
ZyxelCableDiagnosticPortEntry ::= SEQUENCE {
|
|
zyCableDiagnosticPortAction
|
|
INTEGER
|
|
}
|
|
|
|
zyCableDiagnosticPortAction OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none(0),
|
|
start(1),
|
|
clear(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the cable diagnostic test action to be executed on the interface.
|
|
none(0) - No action is executed on the interface.
|
|
When read, the value 'none' is returned.
|
|
start(1) - Start the test on the interface.
|
|
clear(2) - Clear all the test results on the interface.
|
|
The value of the following object of the entry will become 'none'.
|
|
-- zyCableDiagnosticPortActionStatus
|
|
|
|
The value of the following objects of the entry will become 'unknown'.
|
|
-- zyCableDiagnosticPortResultPairAStatus
|
|
-- zyCableDiagnosticPortResultPairBStatus
|
|
-- zyCableDiagnosticPortResultPairCStatus
|
|
-- zyCableDiagnosticPortResultPairDStatus
|
|
|
|
The value of the following objects of the entry will become 'na'.
|
|
-- zyCableDiagnosticPortResultPairALength
|
|
-- zyCableDiagnosticPortResultPairBLength
|
|
-- zyCableDiagnosticPortResultPairCLength
|
|
-- zyCableDiagnosticPortResultPairDLength
|
|
-- zyCableDiagnosticPortResultPairADistanceToFault
|
|
-- zyCableDiagnosticPortResultPairBDistanceToFault
|
|
-- zyCableDiagnosticPortResultPairCDistanceToFault
|
|
-- zyCableDiagnosticPortResultPairDDistanceToFault"
|
|
::= { zyxelCableDiagnosticPortEntry 1 }
|
|
|
|
-- ================================================
|
|
-- Cable Diagnostic Status
|
|
-- ================================================
|
|
zyxelCableDiagnosticStatus OBJECT IDENTIFIER ::= { zyxelCableDiagnostic 2 }
|
|
|
|
-- ================================================
|
|
-- Cable Diagnostic Port Status Table
|
|
-- ================================================
|
|
zyxelCableDiagnosticPortStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ZyxelCableDiagnosticPortStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table containing information about cable diagnostic status on the device's interfaces."
|
|
::= { zyxelCableDiagnosticStatus 1 }
|
|
|
|
-- ================================================
|
|
-- Cable Diagnostic Port Status Entry
|
|
-- ================================================
|
|
zyxelCableDiagnosticPortStatusEntry OBJECT-TYPE
|
|
SYNTAX ZyxelCableDiagnosticPortStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the zyxelCableDiagnosticPortStatusTable, containing the information
|
|
about cable diagnostic status on an interface."
|
|
INDEX { ifIndex }
|
|
::= { zyxelCableDiagnosticPortStatusTable 1 }
|
|
|
|
ZyxelCableDiagnosticPortStatusEntry ::= SEQUENCE {
|
|
zyCableDiagnosticPortStatusActionStatus
|
|
INTEGER
|
|
}
|
|
|
|
zyCableDiagnosticPortStatusActionStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none(0),
|
|
success(1),
|
|
failure(2),
|
|
processing(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the status of the last cable diagnostic test action set on the interface.
|
|
none(0) - The cable diagnostic has never been run for this interface or the previous result has been cleared.
|
|
success(1) - The last cable diagnostic test was done successfully.
|
|
failure(2) - The last cable diagnostic test was failed.
|
|
processing(3) - The cable diagnostic is running currently on the interface."
|
|
::= { zyxelCableDiagnosticPortStatusEntry 1 }
|
|
|
|
-- ================================================
|
|
-- Cable Diagnostic Port Result Table
|
|
-- ================================================
|
|
zyxelCableDiagnosticPortResultTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ZyxelCableDiagnosticPortResultEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table containing information about cable diagnostic test result on the device's interfaces."
|
|
::= { zyxelCableDiagnosticStatus 2 }
|
|
|
|
-- ================================================
|
|
-- Cable Diagnostic Port Result Entry
|
|
-- ================================================
|
|
zyxelCableDiagnosticPortResultEntry OBJECT-TYPE
|
|
SYNTAX ZyxelCableDiagnosticPortResultEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the zyxelCableDiagnosticPortResultTable, containing the information
|
|
about cable diagnostic test result on an interface."
|
|
INDEX { ifIndex }
|
|
::= { zyxelCableDiagnosticPortResultTable 1 }
|
|
|
|
ZyxelCableDiagnosticPortResultEntry ::= SEQUENCE {
|
|
zyCableDiagnosticPortResultPairAStatus
|
|
INTEGER,
|
|
zyCableDiagnosticPortResultPairBStatus
|
|
INTEGER,
|
|
zyCableDiagnosticPortResultPairCStatus
|
|
INTEGER,
|
|
zyCableDiagnosticPortResultPairDStatus
|
|
INTEGER,
|
|
zyCableDiagnosticPortResultPairALength
|
|
INTEGER,
|
|
zyCableDiagnosticPortResultPairBLength
|
|
INTEGER,
|
|
zyCableDiagnosticPortResultPairCLength
|
|
INTEGER,
|
|
zyCableDiagnosticPortResultPairDLength
|
|
INTEGER,
|
|
zyCableDiagnosticPortResultPairADistanceToFault
|
|
INTEGER,
|
|
zyCableDiagnosticPortResultPairBDistanceToFault
|
|
INTEGER,
|
|
zyCableDiagnosticPortResultPairCDistanceToFault
|
|
INTEGER,
|
|
zyCableDiagnosticPortResultPairDDistanceToFault
|
|
INTEGER
|
|
}
|
|
|
|
zyCableDiagnosticPortResultPairAStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ok(1),
|
|
open(2),
|
|
short(3),
|
|
openshort(4),
|
|
crosstalk(5),
|
|
unknown(6),
|
|
unsupported(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the status of the cable pairA."
|
|
::= { zyxelCableDiagnosticPortResultEntry 1 }
|
|
|
|
zyCableDiagnosticPortResultPairBStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ok(1),
|
|
open(2),
|
|
short(3),
|
|
openshort(4),
|
|
crosstalk(5),
|
|
unknown(6),
|
|
unsupported(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the status of the cable pairB."
|
|
::= { zyxelCableDiagnosticPortResultEntry 2 }
|
|
|
|
zyCableDiagnosticPortResultPairCStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ok(1),
|
|
open(2),
|
|
short(3),
|
|
openshort(4),
|
|
crosstalk(5),
|
|
unknown(6),
|
|
unsupported(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the status of the cable pairC."
|
|
::= { zyxelCableDiagnosticPortResultEntry 3 }
|
|
|
|
zyCableDiagnosticPortResultPairDStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ok(1),
|
|
open(2),
|
|
short(3),
|
|
openshort(4),
|
|
crosstalk(5),
|
|
unknown(6),
|
|
unsupported(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the status of the cable pairD."
|
|
::= { zyxelCableDiagnosticPortResultEntry 4 }
|
|
|
|
zyCableDiagnosticPortResultPairALength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the length of the cable pairA.
|
|
The unit of this value is centimeter.
|
|
na(-1) - The length value is invalid or the previous result has been cleared.
|
|
unsupported(-2) - The interface is unsupported for cable diagnostic, such as in fiber mode, port inactive, or chip-self unsupported."
|
|
::= { zyxelCableDiagnosticPortResultEntry 5 }
|
|
|
|
zyCableDiagnosticPortResultPairBLength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the length of the cable pairB.
|
|
The unit of this value is centimeter.
|
|
na(-1) - The length value is invalid or the previous result has been cleared.
|
|
unsupported(-2) - The interface is unsupported for cable diagnostic, such as in fiber mode, port inactive, or chip-self unsupported."
|
|
::= { zyxelCableDiagnosticPortResultEntry 6 }
|
|
|
|
zyCableDiagnosticPortResultPairCLength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the length of the cable pairC.
|
|
The unit of this value is centimeter.
|
|
na(-1) - The length value is invalid or the previous result has been cleared.
|
|
unsupported(-2) - The interface is unsupported for cable diagnostic, such as in fiber mode, port inactive, or chip-self unsupported."
|
|
::= { zyxelCableDiagnosticPortResultEntry 7 }
|
|
|
|
zyCableDiagnosticPortResultPairDLength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the length of the cable pairD.
|
|
The unit of this value is centimeter.
|
|
na(-1) - The length value is invalid or the previous result has been cleared.
|
|
unsupported(-2) - The interface is unsupported for cable diagnostic, such as in fiber mode, port inactive, or chip-self unsupported."
|
|
::= { zyxelCableDiagnosticPortResultEntry 8 }
|
|
|
|
zyCableDiagnosticPortResultPairADistanceToFault OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the distance to the fault point of the cable pairA.
|
|
The unit of this value is centimeter.
|
|
na(-1) - The length value is invalid or the previous result has been cleared.
|
|
unsupported(-2) - The interface is unsupported for cable diagnostic, such as in fiber mode, port inactive, or chip-self unsupported."
|
|
::= { zyxelCableDiagnosticPortResultEntry 9 }
|
|
|
|
zyCableDiagnosticPortResultPairBDistanceToFault OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the distance to the fault point of the cable pairB.
|
|
The unit of this value is centimeter.
|
|
na(-1) - The length value is invalid or the previous result has been cleared.
|
|
unsupported(-2) - The interface is unsupported for cable diagnostic, such as in fiber mode, port inactive, or chip-self unsupported."
|
|
::= { zyxelCableDiagnosticPortResultEntry 10 }
|
|
|
|
zyCableDiagnosticPortResultPairCDistanceToFault OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the distance to the fault point of the cable pairC.
|
|
The unit of this value is centimeter.
|
|
na(-1) - The length value is invalid or the previous result has been cleared.
|
|
unsupported(-2) - The interface is unsupported for cable diagnostic, such as in fiber mode, port inactive, or chip-self unsupported."
|
|
::= { zyxelCableDiagnosticPortResultEntry 11 }
|
|
|
|
zyCableDiagnosticPortResultPairDDistanceToFault OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the distance to the fault point of the cable pairD.
|
|
The unit of this value is centimeter.
|
|
na(-1) - The length value is invalid or the previous result has been cleared.
|
|
unsupported(-2) - The interface is unsupported for cable diagnostic, such as in fiber mode, port inactive, or chip-self unsupported."
|
|
::= { zyxelCableDiagnosticPortResultEntry 12 }
|
|
END |